Text
2RC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9382 b.
REVISION NUMBER 0
c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 1 OF 8
2.
PREAMBLE a.
This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b.
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies including the government of any country through or into which the package will be transported.
3.
THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION.
c.
ISSUED TO (Name and Address)
TN Americas LLC 7160 Riverwood Drive, Suite 200 Columbia, MD 21046 d.
TITLE AND IDENTIFICATION OF REPORT OR APPLICATION TN Eagle Transportation Package Safety Analysis Report, Revision No. 0, dated September 2023.
4.
CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.
5.
(a)
Packaging (1)
Model Nos: TN Eagle SC, TN Eagle LC (2)
==
Description:==
TN Eagle SC and TN Eagle LC The packaging, designed for the transport of spent fuel stored in dry shielded canisters (DSCs),
consists of a forged cask body equipped with a stack of neutron shielding rings shrink fitted onto its outer surface, a bolted steel lid, a steel bottom closure plate, and impact limiters. The bottom of the forged cask has an opening provided for the hydraulic ram access penetration of the cask for DSC loading and unloading operations. The ram access cover plate is part of the bottom closure system and is equipped with inner and outer elastomeric seals. The top and bottom impact limiters are composed of a steel casing enclosing aluminum honeycomb block, VYAL B resin, and a stainless-steel adapter serving as the interface between the cask and the blocks of aluminum honeycomb. A layer of neutron shield resin is placed in the adapter of the impact limiter for additional shielding.
To accept varying DSC lengths, spacers are used (if needed) to limit the axial movement of the payload. In addition, a hollow bottom spacer (to accommodate for the ram access) may be used depending on the DSC length. The containment boundary is defined by the forged cask body, the primary lid and its inner fluorocarbon seals, the lid port plug and its metallic seal, the ram access cover plate, and its inner-fluorocarbon seal.
2RC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9382 b.
REVISION NUMBER 0
c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 2 OF 8
5.(a)(2)
Description (continued)
The TN Eagle SC (Standard Canister) and TN Eagle LC (Large Canister) have the same overall dimensions. However, because of different outside diameters for the DSCs, an inner sleeve is used for smaller diameter DSCs for the TN Eagle SC. The thickness of the forged cask body is different for the TN Eagle SC and TN Eagle LC to allow the loading of larger diameter DSCs.
The EOS-37PTH and EOS-89BTH DSCs are transported in the TN Eagle LC, while the 32PT, 32PTH1, 24PT1, 24PT4, and the Fuel-Only (FO) the Fuel/Control Components (FC), and the Failed Fuel (FF) DSCs are transported in the TN Eagle SC.
For both models, the packaging overall length is 8100 mm (318.90 in.) with the impact limiters and 5598 mm (220.39 in.) without the impact limiters, and the impact limiter outside diameter is 3550 mm (139.76 in.) while the forged cask body outside diameter is 2142 mm (84.33 in.). The TN Eagle SC has (i) a forged cask body inner diameter of 1850 mm (72.83 in.), (ii) a cavity length of 5061 mm (199.25 in.), and (iii) and empty weight of 90,000 kg (198,416 lb). The TN Eagle LC has (i) a forged cask body inner diameter of 1940 mm (76.38 in.), (ii) a cavity length of 5086 mm (200.25 in.), (iii) and an empty weight of 87,400 kg (192,684 lb).
The weight of the impact limiters for both the TN Eagle SC and the TN Eagle LC is 10,200 kg (22,487 lb). The maximum weight of the contents is 55,200 kg (121,695 lb) for the TN Eagle LC and 53,400 kg (111,727 lb) for the TN Eagle SC. The maximum gross weight is 163,000 kg (359,574 lb) for the TN Eagle LC and 164,000 kg (361,558 lb) for the TN Eagle SC.
5.(a)(3)
Drawings TN Eagle SC and TN Eagle LC The package shall be constructed and assembled in accordance with the following TN Americas LLC, Drawing numbers:
TN Eagle Package Drawings TN EAGLE01-1100 Rev 0 TN Eagle LC (Large Canister) and TN Eagle SC (Standard Canister) Transport Package (7 Sheets)
EOS Drawings EOS01-71-1000 Rev 0 NUHOMS EOS System Transportable Canister 37PTH DSC Main Assembly (7 sheets)
EOS01-71-1001 Rev 0 NUHOMS EOS System Transportable Canister 37PTH DSC Shell Assembly (2 sheets)
EOS01-71-1005 Rev 0 NUHOMS EOS System Transportable Canister 89BTH DSC Main Assembly (7 sheets)
2RC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9382 b.
REVISION NUMBER 0
c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 3 OF 8
5.(a)(3)
Drawings, TN Eagle SC and TN Eagle LC (continued)
EOS01-71-1006 Rev 0 NUHOMS EOS System Transportable Canister 89BTH DSC Shell Assembly (2 sheets)
EOS01-71-1010 Rev 0 NUHOMS EOS System Transportable Canister 37PTH DSC Basket Assembly (15 sheets)
EOS01-71-1011 Rev 0 NUHOMS EOS System Transportable Canister 37PTH Basket Transition Rails (6 sheets)
EOS01-71-1020 Rev 0 NUHOMS EOS System Transportable Canister 89BTH DSC Basket Assembly (9 sheets)
EOS01-71-1021 Rev 0 NUHOMS EOS System Transportable Canister 89BTH Basket Transition Rails (7 sheets) 24PT1 Drawings NUH24PT1-71-1000 Rev 0 NUHOMS 24PT1-DSC Main Assembly (6 sheets) 24PT4 Drawings NUH24PT4-71-1001 Rev 1 NUHOMS 24PT4 Transportable Canister for PWR Fuel Basket Assembly (5 sheets)
NUH24PT4-71-1002 Rev 1 NUHOMS 24PT4 Transportable Canister for PWR Fuel Main Assembly (8 sheets)
NUH24PT4-71-1003 Rev 0 NUHOMS 24PT4 Transportable Canister for PWR Fuel Failed Fuel Can (4 sheets) 32PT Drawings NUH32PT-71-1000 Rev 1 NUHOMS 32PT Transportable Canister for PWR Fuel Summary Dimensions (1 sheet)
NUH32PT-71-1001 Rev 2 NUHOMS 32PT Transportable Canister for PWR Fuel Main Assembly (5 sheets)
NUH32PT-71-1002 Rev 2 NUHOMS 32PT Transportable Canister for PWR Fuel Shell Assembly (3 sheets)
NUH32PT-71-1003 Rev 2 NUHOMS 32PT Transportable Canister for PWR Fuel A Basket Assembly (16 Poison/16 Compartment Plates)
(8 sheets)
2RC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9382 b.
REVISION NUMBER 0
c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 4 OF 8
5.(a)(3)
Drawings, TN Eagle SC and TN Eagle LC (continued)
NUH32PT-71-1004 Rev 2 NUHOMS 32PT Transportable Canister for PWR Fuel Aluminum Transition Rail - R90 (2 sheets)
NUH32PT-71-1005 Rev 2 NUHOMS 32PT Transportable Canister for PWR Fuel Aluminum Transition Rail -R45 (1 sheet)
NUH32PT-71-1006 Rev 2 NUHOMS 32PT Transportable Canister for PWR Fuel A/B/C/D Basket Assembly (20 Poison/12 Compartment Plates) (6 sheets)
NUH32PT-71-1007 Rev 2 NUHOMS 32PT Transportable Canister for PWR Fuel A/B/C/D Basket Assembly (24 Poison/8 Compartment Plates) (8 sheets)
FO and FC Drawings DWG-NUH24P-FOFC-71-1000 Rev 0 NUHOMS FO-DSC & FC-DSC for PWR Fuel Main Assembly (5 sheets)
FF Drawings DWG-NUH24P-FF-71-1000 Rev 0 NUHOMS FF-DSC for PWR Fuel Main Assembly (5 sheets) 32PTH1 Drawings NUH32PTH1-71-1000 Rev 2 NUHOMS 32PTH1 Transportable Canister for PWR Fuel Main Assembly (4 sheets)
NUH32PTH1-71-1001 Rev 2 NUHOMS 32PTH1 Transportable Canister for PWR Fuel Basket Shell Assembly (5 sheets)
NUH32PTH1-71-1002 Rev 2 NUHOMS 32PTH1 Transportable Canister for PWR Fuel Shell Assembly (4 sheets)
NUH32PTH1-71-1003 Rev 3 NUHOMS 32PTH1 Transportable Canister for PWR Fuel Basket Assembly (8 sheets)
NUH32PTH1-71-1004 Rev 2 NUHOMS 32PTH1 Transportable Canister for PWR Fuel Transition Rails (7 sheets)
NUH32PTH1-71-1010 Rev 2 NUHOMS 32PTH1 Transportable Canister for PWR Fuel Alternate Top Closure (6 sheets)
NRC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9302 b.
REVISION NUMBER 11 c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 5 OF 8
5.(b)
Contents of Packaging (1)
Type and Form of Material (a)
Intact, damaged or failed unconsolidated Babcock and Wilcox (B&W) 15x15, Westinghouse (WE) 14x14, WE 15x15, WE 17x17, Combustion Engineering (CE) 14x14, CE 15x15 and CE 16x16 class PWR fuel assemblies (with or without control components) that are enveloped by the characteristics listed in Table 1.6.1-1 of the application are shipped in the EOS-37PTH DSC.
(b)
Intact unconsolidated 7x7, 8x8, 9x9, and 10x10 BWR fuel assemblies (with or without channels) that are enveloped by the FA design characteristics listed in Table 1.6.2-1 of the application are transported in the EOS-89BTH DSC.
(c)
Intact (including reconstituted) Westinghouse-CENP 16x16 (CE 16x16) and/or damaged or failed CE 16x16 FAs with Zircaloy or ZIRLO' cladding and UO2 or (U, Er)O2 or (U, Gd)O2 fuel pellets can be transported in the 24 PT4 DSC with the characteristics in Appendix 1.6.3 of the application. Assemblies are with or without integral fuel burnable absorber rods or integral burnable poison rods.
(d)
Intact PWR fuel assemblies with or without control components; damaged and failed fuels, loaded in an FFC, are allowed for the CE 14x14 fuel class in the 24-poison plate configuration with the characteristics described in Appendix 1.6.4 of the application.
(e)
Intact (including reconstituted) PWR fuel assemblies with or without control components; damaged fuel is allowed in the 32PTH1 DSCs with the characteristics described in Appendix1.6.5 of the application.
(f)
Intact WE 14x14 PWR fuel assemblies; UO2 (stainless steel clad) and Mixed Oxide Zircalloy Clad (MOX UO2 and PuO2) fuel assemblies with or without integral control components in the 24PT1 DSC are allowed with the characteristics described in Appendix 1.6.7 of the application. Up to four stainless steel clad damaged or failed FAs in the 24PT1-DSC. A single damaged or failed WE 14x14 MOX FA in the 24PT1-DSC with no other damaged/failed assemblies.
(2)
Maximum quantity of material per package:
(a) 37 PWR fuel assemblies in the TN Eagle LC with the EOS-37PTH DSC and a maximum heat load of 38.4 kW.
(b) 89 BWR fuel assemblies in the TN Eagle LC with the EOS-89BTH DSC and a maximum heat load of 31.15 kW.
2RC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9382 b.
REVISION NUMBER 0
c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 6 OF 8
5.(b)
Contents of Packaging (continued)
(c) 24 intact, damaged, or failed PWR fuel assemblies in the TN Eagle SC with the 24PT4 DSC. Alternatively, up to 12 damaged or failed fuel assemblies in FFC canisters with the balance being loaded with intact fuel. Maximum heat load of 1.26 kW per assembly and a maximum heat load of 24 kW per DSC.
(d) 32 PWR fuel assemblies in the TN Eagle SC with the 32PT DSC in any of four alternate heat zoning configurations with a maximum decay heat of 2.2 kW per assembly and a maximum heat load of 24 kW.
(e) 32 intact (including reconstituted) PWR fuel assemblies in the TN Eagle SC with the 32PTH1 DSC in any of the three alternate heat zoning configurations with a maximum decay heat of 1.5 kW per assembly and a maximum heat load of 26 kW. Up to a maximum of 16 damaged fuel assemblies placed in the center cells of the 32PTH1, with the remainder intact (f) 24PWR fuel assemblies; UO2 and Mixed Oxide Zircalloy Clad (MOX UO2 and PuO2) fuel assemblies with or without integral control components in the TN Eagle SC with the 24PT1 DSC in any of the three alternate heat zoning configurations with a maximum decay heat of 0.583 kW per assembly and a maximum heat load of 14 kW. Up to 4 stainless steel clad damaged or failed fuel assemblies. A single damaged or failed WE 14x14 MOX FA may be stored in the 24PT1 DSC with no other damaged/failed assemblies.
(3)
Damaged fuel includes assemblies with known or suspected cladding defects greater than hairline cracks or pinhole leaks or an assembly with partial and/or missing rods. Damaged fuel assemblies shall be placed in failed fuel canisters (FFC). Loose rods are considered as part of failed fuel contents. The maximum allowable heat load of a package loaded with FO/FC/FF DSC, is 13.5 kW, with a maximum assembly decay heat of 0.764 kW (Type I) or 0.563 kW (Type II) per assembly.
2RC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9382 b.
REVISION NUMBER 0
c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 7 OF 8
5.(d)
Criticality Safety Index:
0 6.
Fuel assemblies with missing fuel rods shall not be shipped as intact fuel unless the missing fuel rods are replaced with dummy rods that displace an equal or greater amount of water.
7.
In addition to the requirements of Subpart G of 10 CFR Part 71, the TN Eagle SC and TN Eagle LC packages shall:
(a)
Be prepared for shipment and operated in accordance with the Operating Procedures in Chapter 8.0, and (b)
Meet the Acceptance Tests and Maintenance Program of Chapter 9.0.
8.
Additional operating requirements of the TN Eagle SC and TN Eagle LC package include:
(a)
Verification that the fuel assemblies to be transported in any DSC meet the characteristics, maximum average initial enrichment and burnup combinations for both intact and failed fuel assemblies as stated in Appendix 1.6 of the application and are loaded per the Fuel Qualification Tables in Appendix 8.7 of the application.
(b)
The aging management plan and evaluation for each DSC, or set of DSCs, shall be submitted to the NRC prior to shipment.
(c)
The package is transported by rail in an exclusive use conveyance only. To ensure adequate fatigue strength is maintained, the packaging is limited to 800 one-way shipments (empty or loaded).
(d)
Lifting the package, while attached to the transport frame, is not authorized. The TN Eagle package is handled solely in a horizontal position.
9.
Transport by air is not authorized.
10 The TN Eagle SC and TN Eagle LC packages authorized by this certificate are hereby approved for use under the general license provisions of 10 CFR 71.17.
11.
Expiration Date: October 31, 2028.
2RC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.
- a. CERTIFICATION NUMBER 9382 b.
REVISION NUMBER 0
c.
DOCKET NUMBER 71-9382 d.
PACKAGE IDENTIFICATION NUMBER USA/9382/B(U)F-96 PAGE PAGES 8 OF 8
REFERENCES TN Eagle Safety Analysis Report, Revision No. 0, dated September 2023.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION Yoira K. Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Date: October 23, 2023 Signed by Diaz-Sanabria, Yoira on 10/23/23