L-2023-112, Corrections to the 2021 Annual Radioactive Effluent Release Report

From kanterella
(Redirected from ML23249A180)
Jump to navigation Jump to search
Corrections to the 2021 Annual Radioactive Effluent Release Report
ML23249A180
Person / Time
Site: Saint Lucie  
Issue date: 09/06/2023
From: Strand D
Florida Power & Light Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
L-2023-112
Download: ML23249A180 (1)


Text

September 06, 2023 L-2023-112 10 CFR 50.36a U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Corrections to the 2021 Annual Radioactive Effluent Release Report

Reference:

FPL letter L-2022-023 dated February 23, 2022: 2021 Annual Radioactive Effluent Release Report By letter dated February 23, 2022 (Reference), Florida Power & Light submitted the 2021 Annual Radioactive Effluent Release Report (ARERR) for St. Lucie Units 1 and 2 pursuant to 10 CFR 50.36a(a)(2) and Technical Specification (TS) 6.9.1.7. The 2021 report provided information for the 12-month period beginning January 1, 2021 and ending December 31, 2021.

Dose calculation errors were found in the land use exposure pathways. Also, an effluent radiation monitor that had been out of service for greater than 30 days should have been reported in Section 2.5. Both items have been corrected and are provided in this submittal. This corrected report replaces the St. Lucie 2021 ARERR report in its entirety.

If you have any questions regarding this submittal, please contact Kenneth Mack at 561-904-3635.

2eKt~

Dian~trand General Manager, Regulatory Affairs Florida Power & Light Company

Enclosure:

Combined Annual Radioactive Effluent Release Report (2021) cc:

USNRC Regional Administrator, Region II USNRC Project Manager, St. Lucie Nuclear Plant USNRC Resident Inspector, St. Lucie Nuclear Plant Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

ENCLOSURE1 L-2022-023 Enclosure COMBINED ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT (10PAGES)

FLORIDA POWER & LIGHT COMP ANY ST. LUCIE UNITS 1 AND 2 L-2022-023 Enclosure ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2021 THROUGH DECEMBER 31, 2021 1.0 PROGRAM DESCRIPTION 2.0 SUPPLEMENTAL INFORMATION 2.1 Abnormal Releases or Abnormal Discharges 2.2 Non-Routine Planned Discharges 2.3 Radioactive Waste Treatment System Changes 2.4 Annual Land Use Census Changes 2.5 Effluent Monitoring System Inoperability 2.6 Off site Dose Calculation Manual Changes 2.7 Process Control Program Changes 2.8 Corrections to Previous Reports 2.9 Other 2.10 Groundwater Protection Program 3.0TABLES 3.1 Gaseous Effluents and Liquid Effluents 3.2 Solid Waste Storage and Shipments 3.3 Dose Assessments 3.4 Visitor Dose

1.0 PROGRAM DESCRIPTION Regulatory Limits L-2022-023 Enclosure The Offsite Dose Calculation Manual (ODCM) Radiological Effluent Control limits applicable to the release of radioactive material in liquid and gaseous effluents are described in the following sections.

Fission and Activation Gases (Noble Gases)

The dose rate due to radioactive materials released in gaseous effluents, from the Site to areas at and beyond the Site boundary, shall be limited to less than or equal to 500 mrem/yr to the whole body and less than or equal to 3000 mrem/yrto the skin.

The air dose due to noble gases released in gaseous effluents from each Unit, to areas at and beyond the Site boundary, shall be limited to:

a. During any calendar qua1ter: Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and
b. During any calendar year: Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.

Iodine-131, Iodine-133, Tritium, Carbon-14, and Radioactive Material in Particulate Form The dose rate due to Iodine-131 (I-131), Iodine-133 (I-133), Tritium, and all radionuclides in particulate form with half-lives greater than 8 days, released in gaseous effluents from the Site to areas at and beyond the Site boundary, shall be limited to less than or equal to 1500 mrem/yr to any organ.

The dose to a MEMBER OF THE PUBLIC from I-131, I-133, Tritium, Carbon-14 (C-14), and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released from each Unit, to areas at and beyond the Site boundary, shall be limited to:

a. During any calendar quarter: Less than or equal to 7.5 mrem to any organ, and
b. During any calendar year: Less than or equal to 15 mrem to any organ.

Liquid Effluents The concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to 10 times the concentrations specified in 10 CFR Part 20, Appendix B, Table 2, Column2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2.0E-4 µCi/ml total activity.

The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released from each Unit, to unrestricted areas, shall be limited to:

a. During any calendar quaiter: Less than or equal to 1.5 mrem to the whole body and less than or equal to 5 mrem to any organ, and
b. During any calendar year: Less than or equal to 3 mrem to the whole body and less than or equal to 10 mrem to any organ.

Total Dose L-2022-023 Enclosure The annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrem to the whole body or any organ, exceptthe thyroid which shall be limited to less than or equal to 75 mrem.

Effluent Concentration Limits Gaseous Effluents For gaseous effluents, effluent concentration limits (ECL) va 1 u es are not directly used in release rate calculations since the applicable limits are expressed in terms of dose rate at the Site boundary.

Liquid Effluents The values specified in 10 CFRPart20, Appendix B, Table 2, Column 2 are used as the ECL for liquid radioactive effluents released to unrestricted areas. A value of 2.0E-04 µCi/ml is used as the ECL for dissolved and entrained noble gases in liquid effluents.

Measurements and Approximations ofTotalRadioactivity Measurements of total radioactivity in liquid and gaseous radioactive effluents were accomplished in accordance with the sampling and analysis requirements of Tables 4.11-1 and 4.11-2, respectively, of the St. Lucie ODCM. Estimates of errors are in accordance with Methodology Section 4.0.4 of the ODCM.

The estimate of errors associated with values rep01ted are below:

Error Topic Release Point Mixing Sampling Sample Preparation Sample Analysis Release Volume Total%

LIQUID Avg%

2 1

1 3

2 9

Max%

5 5

5 10 5

30 GASEOUS Avg%

NA 2

1 3

4 10 Max%

NA 5

5 10 15 35 (above values are examples only)

The predictability of error for radioactive releases can only be applied to nuclides that are predominant in sample spectrnms. Nuclides that are 1 near background relative to the predominant nuclides in a given sample

. could easily have errors greater than the maximums listed above.

Liquid Radioactive Effluents L-2022-023 Enclosure Each batch release was sampled and analyzed for gamma emitting radionuclides using gamma spectroscopy prior to release. Composite samples were analyzed monthly for tritium and gross alpha radioactivity in the onsite laboratory using liquid scintillation and air ion chamber counting techniques, respectively. Composite samples were analyzed quarterly for Strontium-89 (Sr-89), Strontium-90 (Sr-90), Iron-55 (Fe-55),

Nickel-63 (Ni-63 ), and C-14 by a contract laboratory. The results of the composite analyses from the previous month or quarter were used to estimate the quantities of these radionuclides in liquid effluents during the current month or quarter. The total radioactivity in liquid effluent releases was determined from the measured and estimated concentrations of each radionuclide present and the total volume of the effluent released during periods of discharge.

Gaseous Radioactive Effluents Each gaseous batch was sampled and analyzed for radioactivity prior to release. For releases from gas decay tanks, noble gas grab samples were analyzed for gamma emitting radionuclides using gamma spectroscopy.

For releases from the reactor containment buildings, samples were taken of noble gas and tritium grab samples and analyzed for gamma emitting radionuclides prior to each release. The results of the analyses and the total volume of effluent released were used to determine the total amount of radioactivity released in the batch mode.

For continuous effluent release pathways, noble gas and tritium grab samples were collected and analyzed weekly for gamma emitting radionuclides by gamma spectroscopy and liquid scintillation counting techniques, respectively. Continuous release pathways were continua usly sampled using radioiodine absorbers and particulate filters. The radioiodine absorbers and particulate filters were analyzed weekly for gamma emitting radionuclides using gamma spectroscopy. Results of the noble gas and tritium grab samples, radio iodine absorber, and particulate filter analyses from the current week along with the average effluent flow rate for the previous week were used to determine the total amount of radioactivity released in the continuous mode. The particulate filters were analyzed weekly for gross alpha activity in the onsite laboratory using the air ion chamber counting technique. Quarterly composites of particulate filters were analyzed for Sr-89 and Sr-90 by a contract laboratory.

Meteorological Monitoring Program In accordance with ODCM Administrative Contra 1 3.11.2.6.b., a summary of hourly meteorological data collected during 2021 is retained onsite.

This data is available for review by the NRC upon request. During 2 021, the goal of 90% joint data recovery was met. Actual meteorological data

L-2022-023 Enclosure collected during the year was used for the offsite dose calculations in this report.

Carbon-14 Dose Estimation The estimate of C-14 released from the St. Lucie Nuclear Plant was derived from the EPRI document, "Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents", Report 1021106, issued December 2010.

The Site-specific source term values used in the St. Lucie calculations were taken from the PWR Section, Page 4-28 of the report, and employed the proxy generation rate values for a Combustion Engineering reactor.

The actual 2021 operating data for the units was employed for the calculations to derive the total curies released for each unit.

The total amount of C-14 released in 2021 from Unit 1 was 10.20 Ci, and the total amount of C-14 released in 2021 from Unit 2 was 10.32 Ci.

Per Regulatory Guide 1.21, Rev 2, Section 5.7, "Real exposure pathways are identified for routine discharges and direct radiation based on the results of the Land Use Census. Dose calculations should typically be performed based on real exposure pathways". Because the 2021 Land Use Census did not identify any land within 5 miles of Site that met the criteria of a garden per Technical Specification 3.12.2 listed in the ODCM, the highest dose exposure pathway from C-14 was calculated from the collection of citrus frnit at an orchard at a distance of 5 miles in the West sector. A "Child" consuming citrns produced at the orchard located 5 miles in the West direction from Site would have received a total combined "Bone Dose" of 5.68E-2 mrem attributed to C-14.

Assessment of radiation dose from radioactive effluents to a MEMBER OF THE PUBLIC due to activities inside the Site boundaiy assumes the visitor to be a Lifeguard at Walton Rocks Beach Recreation Area, located 1 mile southeast of the site. Dose to the visitor on Site for calendar year 2021 was calculated to be 4.75E-09 mrem Total Body dose. See Section 3.4, Dose Assessments, for more detail.

Radiation dose from radioactive effluents to a MEMBER OF THE PUBLIC due to activities inside the Site boundaty is a :fraction of the 1 mrem annual whole-body dose received by the average US citizen from natural occutTing C-14, primarily generated through cosmogenesis in the te11'estrial biosphere (

Reference:

National Council of Radiation Protection Report 45, Natural Background Radiation in the United States).

All C-14 dose calculations are based on Regulatmy Guide 1.109 values.

2.0 SUPPLEMENTAL INFORMATION 2.1 Abnormal Releases or Abnormal Discharges L-2022-023 Enclosure No abnormal (unplanned) releases or discharges occurred during the report period.

2.2 Non-Routine Planned Discharges No non-routine planned discharges occmTed during the report period.

2.3 Radioactive Waste Treatment System Changes No changes were made to the Radioactive Waste Treatment System during the report period.

2.4 Annual Land Use Census Changes During 2021, no garden greater than 500 ft2 was located within 5 miles of Site. Per Technical Specification 3.12.2 listed in the ODCM, C-200, Page 64, broad leaf vegetation (Brazilian Pepper) sampling was performed at the Site Boundaiy in the 2 sectors (WNW and NW) with the highest predicted D/Qs in lieu of the garden census. Controls for broad leaf vegetation sainpling per ODCM Table 3.12-1, Part 4.b, including collection and analysis of control samples, were followed.

2.5 Effluent Monitoring System Inoperability One effluent radiation monitor was out of service for greater than 30 days during the report period:

Vent Rad Monitor was non-functional and declai*ed out of service on 8/23/2021 due to particulate filter high pressure. As per the Offsite Dose Calculation Manual (ODCM), Table 3.3-13, no actions are requh-ed if SGBTF ventilation is secured. In the event SGBTF ventilation were to be placed in service, ODCM, Table 3.3-13 provides actions required to be performed. SGBTF ventilation fans are cunently off. The SGBTF Rad Monitor is cunently not in service.

2.6 Offsite Dose Calculation Manual Changes No changes were made to the Offsite Dose Calculation Manual during the report period.

2.7 Process Control Program Changes No changes were made to the Process Control Program during the report period.

2.8 Corrections to Previous Reports L-2022-023 Enclosure The 2020 Annual Radioactive Effluent Release Report (L-2021-049) was found to contain an error related to the amount of tritium reported in liquid releases for the third and fourth quaiiers. Further investigation revealed and corrected two additional errors with gaseous release permits being closed on the wrong date, making it appear that the releases were 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> longer (i.e.,

greater) than actual. L-2021-049, Enclosure 1, Table 3.1, Gaseous Effluents and Liquid Effluents, and Table 3.3, Dose Assessments were c011*ected and submitted to the Nuclear Regulat01y Commission in Letter L-2021-225 dated December 14, 2021.

2.9 Other AR 2381903 LOSS OF PRESSURE IN 2C Gas Decay Tank {GDT)

When 2C GDT was placed in service, pressure in the tank dropped from 13 psig to 8 psig. Crew decided to press up the 2C GDT to above 10 psig and swap to the 2A GDT, following a gaseous release of 2A UDT. During the 2A GDT release, 2C GDTpressure d1*opped to 6 psig, when it was then removed from service. 2A GDT was NOT dropping pressure ( once isolated from the release). Per the ODCM, an unplanned release is defined for GDTs as: If a GDT loses greater than 2 psig per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for 9 consecutive shifts, or 18 psig in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, AND the losses were determined to be to the Reactor Auxiliaiy Building Atmosphere, then you must declare the losses an unplanned release.

In this case, the C GDT lost a total of 9 psig in the span of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and was then removed from service, and therefore does not meet the definition of an unplanned release.

AR 2391141 X-5 LIQUID RAD WASTE RADIATION MONITOR FLOW LOW ALARM Equipment Name: Unit 1 RADIATION DETECTOR FOR LIQUID MONITOR CHANNEL 43 Location

Description:

CCW/26/N-957 /E-1731 Equipment Tag: RE-6627 When attempting to perform a release of "A" Waste Monitor Tank per 1-NOP- 06.01, X-5 Liquid Radwaste Rad Monitor Flow Low alarm locked in.

Operations declared RE-6627 Liquid Waste Discharge Radiation Monitor out of service. Release was stopped, and Chemist1y performed additional grab sample of A WMT to allow for release with RE-6627 out of service.

Compensat01y measures implemented: With the Radiation Monitor non-functional, liquid releases can be conducted pr*ovided two (2) independent samples are analyzed and two (2) qual,ified individuals validate the release rate calculation.

L-2022-023 Enclosure AR 2396014 DRAWINGS NEED UPDATED FOR CHANGES MADE TO UNIT 1 GAS ANALYZER Equipment Name: Unit 1 Waste Gas Decay Tank Oxygen Analyzer Location

Description:

RAB/19.5/N-RA3/E-RAH - AUTO GAS ANALYZER I&C perfo1med modifications on the Unit 1 Gas Analyzers for O2Y-6601 and O2Y-6602 to remove piping and pumps and left only the piping from the 1A, 1B, and lC Gas Decay Tanks (GDTs). PCR 2389176 was generated to change procedure 1-NOP-06.23 to allow for alignment of the GDTs to the waste gas analyzer; however, it does not appear the associated plant drawings were changed. 8770-3089 and 8770-G-078 SHT 164 need to be updated for these changes. The required compensatory measures are in effect.

Compensat01y measures implemented: Chemist1y once-per-24-hour grab sampling.

South Pond Settling Basin Release Summary Seventeen batch releases from the South Settling Basin to the Intake Canal to lower the water level due to periods of higher than normal rainfall occurred during the report period. All releases were analyzed according to the ODCM and Site procedural requirements and were found to have no detectable gamma, tritium, alpha, or hard-to-detect isotopes. The releases are summarized below.

2021 South Pond Releases Volume Sample Date Permit#

(Gallons)

Quarter 1

1/12/21 L-21-056-B 1,926,930 Ql 2

2/9/21 L-21-065-B 4,248,114 3

3/18/21 L-21-084-B 2,622,517 4

4/10/21 L-21-085-B 2,679,997 Q2 5

5/5/21 L-21-105-B 2,109,765 6

6/4/21 L-21-106-B 1,681,699 7

6/16/21 L-21-109-B 6,495,301 8

6/24/21 L-21-111-B 754,551 9

7/1/21 L-21-115-8 154,381 Q3 10 8/5/21 L-21-132-B 7,209,746 11 8/12/21 L-21-133-B 2,954,550 12 8/29/21 L-21-137-B 7,480,000 13 9/9/21 L-21-138-B 3,940,000 14 9/20/2.1 L-21-144-B 2,623,830 15 11/12/21 L-21-146-B 2,455,064 Q4 16 11/22/21 L-21-147-B 1,700,292 17 12/18/21 L-21-001-B 3,416,128

L-2022-023 Enclosure 2.10 Groundwater Protection Program No limits were exceeded for the St. Lucie Nuclear Site Groundwater Protection Program during the report period. The tritium results for the report period are contained in the table below.

2021 St. Lucie Nuclear Plant Groundwater Protection Program Tritium Results (pCi/L)

Well ID Jan Feb March April Oct Nov Dec 1MW001 1MW0D2 1MWD03 1MW004 1MW005 2MWOD1 2MW002 2MW003 2MW004 MW-15 MW-16 MW-17 MW-18d MW-19 MW-22d MW-26 MW-3 MW-30 MW-31 MW-32 MW-33 MW-4 MW-5 MW-6 MW-7 NB-MW-1 NB-MW-2 PSLED-2 RW-2 RW-4 RW-5 S-MW-1 S-l\'1\11/-11 S-MW-15D S-MW-16 s-r111W-l6i S-MW-17 S-MW-18 S-MW-19 S-MW-4 S-MW-6 S-MW-7A

3.0 TABLES 3.1 Gaseous Effluents and Liquid Effluents 3.2 Solid Waste Storage and Shipments 3.3 Dose Assessments 3.4 Visitor Dose L-2022-023 Enclosure

TABLE3.1 GASEOUS EFFLUENTS AND LIQUID EFFLUENTS (26PAGES)

L-2022-023 Enclosure

_,;_ EMS EHluet Mm~.::mem S,::ifo?.~trl!

Reg. Guide 1.21r Table SA and SB - Liquid and Gas Batch Release Summary Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 A. Liquid Batch Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter

1. Number of Batch Releases 20 35 29
2. Total duration of batch releases min 3.51E+04 5.55E+04 6.21E+04
3. Maximum batch release duration min 8.64E+03 8.63E+03 8.88E+03
4. Average batch release duration min 1.75E+03 1.59E+03 2.14E+03
5. Minimum batch release duration min 3.77E+02 5.09E+02 4.45E+02 B. Gas Batch Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter
1. Number of Batch Releases 58 68 75
2. Total duration of batch releases min 1.98E+04 7.42E+04 7.33E+04
3. Maximum batch release duration min 1.59E+03 1.98E+04 1.03E+04
4. Average batch release duration min 3.41E+02 1.09E+03 9.77E+02
5. Minimum batch release duration min 2.50E+01 1.70E+01 2.20E+01 User: admin Friday, February 11, 2022 1:30:31PM Florida Power & Light St. Lucie Power Plant 4th Quarter Year Totals 8

92 2.33E+04 1.76E+05 8.66E+03 8.88E+03 2.91E+03 1.91E+03 7.48E+02 3.77E+02 4th Quarter Year Totals 54 255 1.85E+04 1.86E+05 6.00E+02 1.98E+04 3.42E+02 7.29E+02 4.00E+0l 1.70E+01

[Server]: PSLSA137 [Database]: NEPSOEMF

  • .,,... _~,,*,

EMS A. Liquid Abnormal Release Totals

1. Number of Abnormal Releases
2. Total Activity of abnormal releases B. Gas Abnormal Release Totals
1. Number of Abnormal Releases
2. Total Activity of abnormal releases User: admin Reg. Guide 1.21, Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units 1st Quarter 2nd Quarter 3rd Quarter 0

0 0

Ci 0.00E+00 0.00E+00 0.00E+00 Units 1st Quarter 2nd Quarter 3rd Quarter 0

0 0

Ci 0.00E+00 0.00E+00 0.00E+00 Friday, February 11, 2022 1:32:21PM Florida Power & Light St. Lucie Power Plant 4th Quarter Year Totals 0

0 0.00E+00 0.00E+00 4th Quarter Year Totals 0

0 0.00E+00 0.00E+00

[SeNer]: PSLSA137 [Database]: NEPSOEMF

1EMS EfBm.:ot Jvl.:u1;i;:,,--::mcnt Sofo,,:am:

Total Release A. Fission and Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Limit B. Iodines and Halogens
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit
c. Particulates
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit E. Gross Alpha
1. Total Release F.Carbon-14
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit User: admin Reg. Guide 1.21, Table 1A, Gaseous Effluents - Summation of All Releases Unit: Site Units Ci uCi/s Ci uCi/s Ci uCi/s Ci uCi/s Ci Ci uCi/s Starting: 1-Jan-2021 Ending: 31-Dec-2021 1STQuarter 6.66E-01 8.56E-02 1.02E-05 1.31E-06 0.00E+00 0.0OE+0O 8.57E-01 1.lDE-01 0.00E+00 5.56E+00 7.lSE-01 2ND Quarter 1.73E+00 2.19E-Dl 2.59E-05 3.30E-06 l.16E-07 l.47E-08 5.45E+00 6.93E-01 3.19E-08 4.SlE+00 5.74E-01 3RD Quarter 3.87E+00 4.87E-Dl 1.23E-06 1.54E-07 1.37E-06 1.72E-07 3.54E+00 4.46E-01 2.18E-09 4.73E+00 5.95E-01 4TH Quarter 1.03E+Dl 1.30E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.90E+00 2.39E-01 4.83E-09 5.70E+00 7.18E-0l Page 1 of 1 Friday, February 11, 2022 1:34:56PM Florida Power & Light St. Lucie Power Plant Annual 1.66E+Dl 5.27E-Dl 3.73E-05 l.18E-06 1.49E-06 4.71E-08 l.18E+0l 3.73E-01 3.89E-08 2.0SE+0l 6.SDE-01 Uncertainty

[Server]: PSLSA137 [Database]: NEPSOEMF

EMS Total Release A. Fission and Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Limit B. Iodines and Halogens
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit
c. Particulates
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of _Limit, E. Gross Alpha
1. Total Release F. Carbon-14
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit User: admin Reg. Guide 1.21, Table 1A, Gaseous Effluents - Summation of All Releases Unit: PSL1 Units Ci uCi/s Ci uCi/s Ci uCi/s Ci uCi/s Ci Ci uCi/s Starting: 1-Jan-2021 Ending: 31-Dec-2021 1ST Quarter 3.28E-01 4.22E-02 8.89E-06 1.14E-06 0.D0E+00 0.D0E+00 5.SlE-01 7.0SE-02 O.00E+00 2.83E+00 3.64E-01 2ND Quarter 4.79E-01 6.09E-02 2.54E-05 3.24E-06 1.16E-07 1.47E-08 5.32E+D0 6.77E-01 3.19E-08 1.64E+00 2.09E-01 3RD Quarter 3.0DE-01 3.78E-02 0.0DE+O0 0.00E+0D 0.00E+0D 0.0DE+00 1.34E+DD 1.68E-01 0.0DE+D0 2.90E+00 3.65E-01 4TH Quarter 2.SSE-01 3.59E-02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.58E+00 1.99E-01 4.83E-09 2.81E+00 3.54E-01 Page 1 of 1 Friday, February 11, 2022 1:33:35PM Florida Power & Light St. Lucie Power Plant Annual 1.39E+00 4.41E-02 3.43E-05 1.09E-06 1.16E-07 3.67E-09 8.79E+00 2.79E-01 3.67E-08 1.02E+01 3.23E-01 Uncertainty

[Server]: PSLSA137 [Database]: NEPSOEMF

EMS Total Release A. Fission and Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Limit B. Iodines and Halogens
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit C. Particulates
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit E. Gross Alpha
1. Total Release F. Carbon-14
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit User: admin Reg. Guide 1.21, Table 1A, Gaseous Effluents - Summation of All Releases Unit: PSL2 Units 0

uCi/s Ci uCi/s Ci uO/s Ci uO/s Ci 0

uCi/s Starting: 1-Jan-2021 Ending: 31-Dec-2021 1STQuarter 3.38E-01 4.34E-02 1.29E-06 1.66E-07 0.00E+00 0.00E+00 3.0?E-01 3.94E-02 0.00E+00 2.73E+00 3.SlE-01 2ND Quarter 1.25E+00 1.59E-01 4.89E-07 6.22E-08 0.00E+00 0.00E+00 1.26E-01 1.60E-02 0.00E+00 2.87E+00 3.65E-01 3RD Quarter 3.57E+00 4.S0E-01 1.23E-06 1.54E-07 1.37E-06 1.72E-07 2.21E+00 2.78E-01 2.18E-09 1.83E+00 2.30E-01 4TH Quarter 1.01E+01 1.27E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.21E-01 4.04E-02 0.00E+00 2.89E+00 3.64E-01 Page 1 of 1 Friday, February 11, 2022 1:34:23PM Florida Power & Light St. Lucie Power Plant Annual 1.52E+01 4.82E-0l 3.0lE-06 9.54E-08 1.37E-06 4.35E-08 2.96E+00 9.39E-02 2.18E-09 1.03E+01 3.27E-01 Uncertainty

[Server]: PSLSA137 [Database]: NEPSOEMF

__ EMS, Efflw.:L1;: JVl.anagt:m-::nt Sdhv:m:

Page 1 of 3 Friday, February 11, 2022 1:37:02PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Nuclides Released A. Fission and Activation Gases Ar-41 Kr-85m Xe-13lm Xe-135 Xe-135m Total For Period B. Iodines and Halogens I-131 I-133 Total For Period C. Particulates Cr-51 D. Tritium H-3 E. Gross Alpha G-Alpha F, Carbon-14 C-14 Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units Ci Ci Ci Ci a ---

Ci Ci Ci Ci Ci Ci Ci Ci lSTQuarter 0.00E+00 3.82E-02 0.0OE+00 3.91E-02 0.00E+00 7.73E-02 1.87E-06 8.31E-06 1.02E-05 0.00E+00 0.00E+00 0.00E+00 5.56E+00 2ND Quarter 4.64E-01 0.00E+00 0.00E+00 1.55E-01 5.47E-01 1.17E+00 3.46E-06 2.25E-05 2.59E-05 0.00E+00 0.00E+00 2.39E-08 4.51E+00 Continuous Mode 3RD Quarter 0.00E+00 0.00E+00 8.0SE-01 0.00E+00 0.00E+00 8.0SE-01 8.67E-07 0.00E+00 8.67E-07 5.09E-07 1.29E+00 2.lBE-09 4.73E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter 0.00E+00 0.00E+00 9.85E+00 0.00E+00 0.00E+00 9.85E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.45E+00 4.83E-09 5.70E+00 Annual 4.64E-01 3.82E-02 1.07E+0l 1.94E-01 5.47E-01 1.19E+01 6.20E-06 3.0SE-05 3.70E-05 5.09E-07 2.74E+00 3.09E-08 2.0SE+0l

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:37 Page 2 of 3 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases Ar-41 Ci 5.0SE-01 3.77E-01 2.26E+DD 4.58E-01 3.60E+D0 Kr-85m Ci 5.46E-05 4.83E-06 1.58E-05 0.D0E+0D 7.52E-05 Kr-87 Ci 0.00E+DD 0.00E+00 1.23E-04 0.00E+00 1.23E-04 Kr-88 Ci D.00E+00 0.0DE+00 1.36E-04 1.17E-04 2.54E-04 Kr-89 Ci 1.82E-02 0.00E+00 0.00E+D0 0.D0E+00 1.82E-02 Xe-127 Ci 0.00E+00 4.25E-05 2.23E-05 0.00E+00 6.48E-05 Xe-131m Ci 0.00E+00 0.00E+00 1.67E-04 0.D0E+00 1.67E-04 Xe-133m Ci 0.00E+00 1.lSE-03 2.07E-04 0.D0E+00 1.36E-03 Xe-135 Ci 1.8DE-03 1.98E-02 1.lSE-03 1.2DE-03 2.39E-02 Xe-133 Ci 6.25E-02 1.62E-01 8.lDE-01 3.44E-02 1.07E+00 Xe-135m Ci 2.SBE-04 0.00E+D0 0.00E+D0 0.00E+D0 2.58E-04 Xe-138 Ci 3.95E-04 0.00E+00 3.66E-05 0.DDE+00 4.31E-04 Total For Period Ci S.89E-01 S.G0E-01 3.07E+00 4.94E-01 4.71E+00 B. Iodines and Halogens I-131 Ci 0.00E+00 0.00E+00 2.16E-07 0.00E+00 2.16E-07 I-133 Ci 0.00E+D0 0.0DE+DD 1.44E-07 0.00E+00 1.44E-07 Total For Period Ci 0.00E+00 0.00E+00 3.G0E-07 0.00E+00 3.G0E-07 C. Particulates Co-60 Ci 0.0DE+00 0.00E+00 2.95E-07 0.00E+00 2.95E-07 Zn-65 Ci O.00E+0D 0.00E+00 3.93E-07 0.00E+0D 3.93E-07 Nb-95 Ci 0.00E+00 1.16E-07 1.73E-07 0.00E+00 2.89E-07 Total For Period Ci 0.00E+00 1.16E-07 8.61E-07 0.00E+00 9.77E-07 If Not Detected, N~clide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:37 Nuclides Released D. Tritium H-3 E. Gross Alpha G-Alpha F. Carbon-14 No Nuclides Found Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Units lSTQuarter 2ND Quarter 3RD Quarter Ci 8.57E-01 5.45E+00 2.26E+00 Ci 0.00E+00 8.0lE-09 0.00E+00 Ci 0.00E+00 0.00E+O0 0.00E+00 Page 3 of 3 4TH Quarter Annual 4.S0E-01 9.0lE+00 0.00E+00 8.0lE-09 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

      • .,---,. EMS**

,1_ } __.

Efrlw.:nt.lv'bn~--::m<.."Dt Sdb.*,-;i.re Page 1 of 3 Friday, February 11, 2022 1:35:41PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: PSL1 Nuclides Released A. Fission and Activation Gases Xe-135 B. Iodines and Halogens I-131 I-133 Total For Period

c. Particulates No Nuclides Found D. Tritium H-3 E. Gross Alpha G-Alpha F.Carbon-14 C-14 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units Ci Ci Ci Ci Ci Ci Ci Ci 1STQuarter 0.00E+00 S.81E-07 8.31E-06 8.89E-06 0.00E+00 0.00E+00 0.00E+00 2.83E+00 2ND Quarter l.55E-01 2.97E-06 2.25E-05 2.54E-05 0.00E+00 0.00E+00 2.39E-08 1.64E+00 Continuous Mode 3RD Quarter 0.00E+00 0.00E+00 0.00E+00 0,00E+00 0.. O0E+00 1.15E+00 0.00E+00 2.90E+00 If Not Detected1 Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.30E+00 4.83E-09 2.81E+00 Annual 1.55E-01 3.55E-06 3.08E-05 3.43E*05 0.00E+00 2.45E+00 2.87E-08 1.02E+0l

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:35 Page 2 of 3 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSLl Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Nuclides Released Units 1STQuarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases Ar-41 Ci 2.92E-01 1.68E-01 2.77E-01 2.73E-01 1.01E+00 Kr-87 0

0.00E+00 0.00E+D0 1.23E-04 0.00E+00 1.23E-04 Kr-88 0

0.0DE+00 0.00E+00 1.36E-04 1.17E-04 2.54E-04 Kr-89 Ci 1.82E-02 0.00E+00 0.00E+00 0.0DE+D0 1.82E-02 Xe-127 Ci 0.00E+00 4.25E-05 0.00E+D0 0.00E+DD 4.25E-05 Xe-135 Ci 1.56E-04 1.91E-02 1.46E-04 4.23E-05 1.94E-02 Xe-133m Ci 0.0DE+00 1.15E-03 0.00E+D0 0.00E+00 1.15E-03 Xe-133 0

1.75E-02 1.36E-01 2.25E-02 1.20E-02 1.88E-01 Xe-135m Ci 2.SBE-04 D.0DE+00 0.00E+D0 0.D0E+D0 2.SBE-04 Xe-138 0

3.95E-04 0.0DE+00 0.00E+D0 0.00E+00 3.95E-04 Total For Period Ci 3.28E-01 3.24E-01 3.00E-01 2.SSE-01 1.24E+00 B. Iodines and Halogens No Nuclides Found 0

0.DDE+00 0.0DE+00 0.00E+D0 0.00E+DD 0.0DE+00

c. Particulates Nb-95 0

0.DDE+DD 1.16E-07 0.00E+D0 0.00E+00 1.16E-07 D. Tritium H-3 Ci 5.SlE-01 5.32E+00 1.BSE-01 2.78E-01 6.34E+00 E. Gross Alpha G-Alpha Ci O.0DE+00 8.0lE-09 0.00E+00 0.00E+00 8.0lE-09 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin

[Server]: PSL5A137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:35 Nuclides Released F.Carbon-14 No Nuclides Found Reg. Guide 1.21, Table 18, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL1 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter Ci 0.00E+00 O.00E+00 0.00E+00 Page 3 of 3 4TH Quarter Annual 0.0OE+00 0.00E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

EMS, Efrlm:nt Iv~mq:-m Sdi:v,:;u-i:

Page 1 of 3 Friday, February 11, 2022 1:36:20PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Nuclides Released A. Fission and Activation Gases Ar-41 Kr-85m Xe-131m Xe-135 Xe-135m Total For Period B. Iodines and Halogens I-131

c. Particulates Cr-51 D. Tritium H-3 E. Gross Alpha G-Alpha F. Carbon-14 C-14 Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter Ci 0.0DE+DD 4.64E-01 0.0DE+00 Ci 3.82E-02 0.00E+00 0.00E+00 Ci 0.00E+00 0.00E+00 8.0SE-01 Ci 3.91E-02 0.00E+00 0.00E+00 Ci 0.00E+00 5.47E-01 0.00E+00 Ci 7,73E-02 1.01E+00 8.0SE-01 Ci 1.29E-06 4.89E-07 8.67E-07 Ci 0.00E+00 O.00E+00 5.09E-07 Ci 0.00E+00 0.00E+00 1.34E-01 Ci 0.00E+00 0.0OE+O0 2.lSE-09 Ci 2.73E+00 2.87E+00 1.83E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter Annual 0.DDE+00 4.64E-01 0.00E+00 3.82E-02 9.85E+00 1.07E+01 0.00E+00 3.91E-02 0.00E+00 5.47E-01 9.SSE+00 1.17E+D1 0.00E+00 2.65E-06 0.00E+00 5.09E-07 1.49E-01 2.83E-01 0.00E+00 2.18E-09 2.89E+00 1.03E+0l

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, _St. Lucie Power Plant 2/11/2022 13:36 Page 2 of3 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Nuclides Released Units lSTQuarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases Ar-41 Ci 2.14E-01 2.09E-01 1.98E+00 1.SSE-01 2.59E+00 Kr-85m Ci 5.46E-05 4.83E-06 1.SSE-05 0.00E+00 7.52E-05 Xe-127 Ci 0.00E+00 0.00E+00 2.23E-05 0.00E+00 2.23E-05 Xe-131m a

0.00E+00 0.00E+00 1.67E-04 0.00E+00 1.67E-04 Xe-133m Ci 0.00E+00 0.00E+0O 2.0?E-04 0.00E+00 2.0?E-04 Xe-135 Ci 1.64E-03 7.0?E-04 1.00E-03 1.16E-03 4.SlE-03 Xe-133 Ci 4.S0E-02 2.64E-02 7.88E-01 2.24E-02 8.82E-01 Xe-138 Ci 0.00E+00 0.00E+00 3.66E-05 0.00E+00 3.66E-05 Total For Period Ci 2.60E-01 2.36E-01 2.77E+00 2.09E-01 3.47E+00 B. Iodines and Halogens I-131 Ci 0.00E+00 0.00E+00 2.16E-07 0.00E+00 2.16E-07 I-133 Ci 0.00E+00 0.00E+00 1.44E-07 0.00E+00 1.44E-07 Total For Period Ci 0.00E+00 0.00E+O0 3.60E*07 O.00E+00 3.60E-07

c. Particulates Co-60 Ci 0.00E+00 0.00E+00 2.95E-07 0.00E+00 2.95E-07 Zn-65 Ci 0.00E+00 0.00E+00 3.93E-07 0.00E+00 3.93E-07 Nb-95 0

0.00E+00 O.00E+00 1.73E-07 0.00E+00 1.73E-07 Total For Period Ci 0.00E+00 0.00E+00 8.61E-07 0.00E+00 8.61E-07 D. Tritium H-3 Ci 3.07E-01 1.26E-01 2.07E+00 1.72E-01 2.68E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:36 Nuclides Released E. Gross Alpha No Nuclides Found F.Carbon-14 No Nuclides Found Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Units 1STQuarter 2ND Quarter 3RD Quarter Ci O.OOE+DD O.OOE+DD O.OOE+OD Ci O.OOE+OO O.OOE+DO O.OOE+OO Page 3 of 3 4TH Quarter Annual O.OOE+OO O.OOE+OO O.DOE+OO O.OOE+OO If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

~~EMS Total Release A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release User: admin Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: Site Units Ci uCi/mL Ci uCi/mL Ci uCi/mL Ci uCi/mL Liters Liters Starting: 1-Jan-2021 Ending: 31-Dec-2021 1ST Quarter 1.56E-02 1.17E-10 3.47E+02 2.60E-06 7.lSE-04 5.35E-12 0.00E+00 0.00E+00 3.49E+07 1.34E+ll 2ND Quarter 1.39E-02 7.00E-11 2.78E+02 1.40E-06 8.47E-03 4.26E-ll 0.00E+00 0.00E+00 5.49E+07 1.99E+ll 3RID Quarter l.41E-02 8.93E-ll l.61E+02 1.02E-06 9.04E-03 5.74E-11 O.00E+00 0.00E+00 9.45E+07 1.58E+ll 4TH Quarter 3.35E-03 4.36E-ll 2.16E+0l 2.81E-07 6.49E-05 8.43E-13 0.00E+0O 0.0OE+00 2.92E+07 7.69E+10 Page 1 of 1 Friday, February 11, 2022 1:39:14PM Florida Power & Light St. Lucie Power Plant Annual 4.69E-02 8.28E-ll 8.08E+02 1.42E-06 1.83E-02 3.23E-ll 0.00E+00 0.00E+00 2.14E+08 5.67E+ll Uncertainty

[Server]: PSLSA137 [Database]: NEPSOEMF

c::EMS, E}lm:nt.lvl.;magtment So+/-i:v..-;m:

Total Release A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release User: admin Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: PSL1 Units Ci uCi/mL 0

uCi/mL 0

uCi/mL Ci uCi/mL Liters Liters Starting: 1-Jan-2021 Ending: 31-Dec-2021 1ST Quarter 7.B0E-03 1.17E-10 1.73E+02 2.60E-06 3.57E-04 5.35E-12 0.00E+00 0.00E+00 l.74E+07 6.68E+l0 2ND Quarter 6.96E-03 7.00E-11 1.39E+02 1.40E-06 4.23E-03 4.26E-11 0.00E+00 0.00E+00 2.75E+07 9.94E+10 3RD Quarter 7.04E-03 8.93E-11 8.06E+0l 1.02E-06 4.52E-03 5.74E-11 0.00E+00 0.00E+00 4.73E+07 7.88E+10 4TH Quarter 1.68E-03 4.36E-11 1.0BE+0l 2.BlE-07 3.24E-05 8.43E-13 0.00E+00 0.00E+00 l.46E+07 3.85E+10 Page 1 of 1 Friday, February 11, 2022 1:37:52PM Florida Power & Light St. Lucie Power Plant Annual 2.35E-02 8.28E-11 4.04E+02 l.42E-06 9.15E-03 3.23E-11 0.00E+00 0.00E+00 l.07E+08 2.84E+ll Uncertainty

[Seiver]: PSLSA137 [Database]: NEPSOEMF

-*- EMS E11uent Ivl:ut~--i:ment S,:Jft1,:tr,e Total Release A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit
c. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F, Dilution Volume
1. Total Release User: admin Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: PSL2 Units 0

uO/mL Ci uCi/mL 0

uCi/mL 0

uCi/mL Liters Liters Starting: 1-Jan-2021 Ending: 31-Dec-2021 1STQuarter 7.80E-03 1.l?E-10 1.73E+02 2.60E-06 3.S?E-04 5.35E-12 0.00E+00 0.00E+00 1.74E+07 6.68E+10 2ND Quarter 6.96E-03 7.00E-11 1.39E+02 1.40E-06 4.23E-03 4.26E-11 0.00E+00 O.O0E+00 2.75E+07 9.94E+10 3RD Quarter 7.04E-03 8.93E-11 8.06E+01 1.02E-06 4.52E-03 5.74E-11 0.00E+00 0.00E+00 4.73E+07 7.88E+10 4TH Quarter 1.68E-03 4.36E-11 1.08E+01 2.81E-07 3.24E-05 8.43E-13 0.00E+00 0.00E+00 1.46E+07 3.85E+10 Page 1 of 1 Friday, February 11, 2022 1:38:29PM Florida Power & Light St. Lucie Power Plant Annual 2.35E-02 8.28E-11 4.04E+02 1.42E-06 9.15E-03 3.23E-11 0.00E+0O 0.00E+00 1.07E+08 2.84E+11 Uncertainty

[Server]: PSLSA137 [Database]: NEPSOEMF

EMS Efr1w.:nt lvlan.Jf;-:::mi.."J:!t S,:.,ft,,van:

Nuclides Released A. Fission and Activation Products No Nuclides Found B. Tritium No Nuclides Found C. Dissolved and Entrained Gases No Nuclides Found D. Gross Alpha Activity No Nuclides Found Reg. Guide 1.21r Table 2Br Liquid Effluents - Continuous Mode Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Continuous Mode Units 1STQuarter 2ND Quarter 3RD Quarter Ci O.OOE+OO O.OOE+OO O.OOE+OO 0

O.OOE+OO O.OOE+OO O.OOE+OO 0

O.OOE+OO O.OOE+OO O.OOE+OO Ci O.OOE+OO O.OOE+OO O.OOE+OO If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin Page 1 of 3 Friday, February 11, 2022 1:41:21PM Florida Power & Light St. Lucie Power Plant 4TH Quarter Annual O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:41 Page 2 of 3 Nuclides Released A. Fission and Activation Products C-14 Na-24 Be-7 Cr-51 Mn-54 Fe-59 Co-58 Co-60 Ni-63 Ni-65 Zn-65 Sr-91 Y-92 Zr-95 Nb-95 Nb-97 Ru-103 Ag-110m Sb-124 Sb-122 Sb-125 Te-123m Te-129m Te-132 I-131 I-132 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter a

7.44E-03 3.28E-03 2.76E-03 Ci 8.89E-06 5.16E-05 3.87E-05 a

0.00E+00 1.SSE-04 2.66E-05 Ci 8.71E-05 S.S0E-05 7.0SE-04 Ci 3.91E-05 2.74E-04 2.39E-04 Ci 9.56E-06 0.00E+00 1.45E-04 Ci 6.06E-04 2.61E-03 1.51E-03 Ci 1.S0E-03 2.53E-03 2.21E-03 a

1.83E-03 9.60E-04 6.56E-04 Ci 0.00E+0O 1.76E-05 0.00E+00 a

1.25E-05 1.S0E-04 1.0lE-04 Ci 4.15E-06 0.00E+00 0.00E+00 Ci 0.00E+00 0.00E+00 7.43E-05 Ci 2.24E-05 4.57E-06 6.21E-04 a

5.94E-05 8.86E-05 1.0SE-03 Ci 3.00E-04 1.?SE-04 4.95E-04 Ci 5.63E-06 0.00E+00 0.00E+00 Ci 1.37E-04 1.65E-04 4.25E-04 Ci 3.82E-04 1.59E-03 1.00E-03 Ci 0.00E+00 5.45E-05 0.00E+00 Ci 3.0lE-03 1.40E-03 9.48E-04 Ci 4.87E-06 6.96E-05 0.00E+00 a

0.00E+00 0.00E+00 7.82E-04 a

0.00E+00 1.16E-04 0.00E+00 Ci 0.00E+00 2.18E-06 0.00E+00 Ci O.00E+00 1.19E-04 0.00E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter Annual 6.81E-04 1.42E-02 3.33E-06 1.03E-04 0.00E+00 1.SSE-04 1.77E-04 1.02E-03 3.78E-05 5.90E-04 0.00E+00 1.54E-04 1.15E-03 5.SSE-03 5.96E-04 6.84E-03 3.62E-04 3.81E-03 0.00E+00 1.76E-05 0.00E+00 2.64E-04 0.00E+00 4.15E-06 0.00E+00 7.43E-05 4.13E-05 6.90E-04 6.74E-05 1.26E-03 4.95E-05 1.02E-03 0.00E+00 5.63E-06 4.51E-05 7.72E-04 5.45E-05 3.03E-03 0.00E+00 5.45E-05 7.0SE-05 5.43E-03 0.00E+00 7.45E-05 0.00E+00 7.82E-04 0.00E+00 1.16E-04 0.00E+00 2.lSE-06 0.00E+00 1.19E-04

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:41 Page 3 of 3 Reg. Guide 1.21, Table 28, Liquid Effluents - Batch Mode Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter Cs-137 Ci 1.37E-04 4.02E-05 0.00E+00 La-140 Ci 0.00E+00 0.00E+00 2.75E-04 W-187 0

0.00E+00 0.00E+00 1.19E-05 Total For Period Ci 1.56E-02 1.39E-02 1.41E-02 B. Tritium H-3 0

3.47E+02 2.78E+02 1.61E+02 C. Dissolved and Entrained Gases Ar-41 Ci O.00E+00 1.48E-04 0.00E+00 Kr-85m 0

0.00E+00 3.25E-06 0.00E+00 Kr-88 0

0.00E+00 8.82E-06 0.00E+00 Xe-131m Ci 0.00E+00 0.00E+00 5.75E-05 Xe-135 0

0.00E+00 4.51E-05 4.34E-06 Xe-133m Ci 0.0OE+00 9.48E-05 5.19E-05 Xe-133 Ci 7.15E-04 8.17E-03 8.93E-03 Total For Period Ci 7.lSE-04 8.47E-03 9.04E-03 D. Gross Alpha Activity No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter Annual 1.32E-05 1.90E-04 0.00E+00 2.75E-04 0.00E+00 1.19E-05 3.35E-03 4.69E-02 2.16E+0l 8.08E+02 0.00E+00 1.48E-04 0.00E+00 3.25E-06 0.00E+00 8.82E-06 0.00E+00 5.75E-05 2.S0E-06 5.19E-05 0.00E+00 1.47E-04 6.24E-05 1.79E-02 6.49E-05 1.83E-02 0.00E+00 0.00E+00

[Server]: PSLSA137 [Database]: NEPSOEMF

EMS Ellw.:nt.l\,*lanagem~11t Sdi:w:rn:

Nuclides Released A. Fission and Activation Products No Nuclides Found B. Tritium No Nuclides Found C. Dissolved and Entrained Gases No Nuclides Found D, Gross Alpha Activity No Nuclides Found Reg. Guide 1.21, Table 2B, Liquid Effluents - Continuous Mode Unit: PSL1 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Continuous Mode Units 1STQuarter 2ND Quarter 3RD Quarter Ci 0.00E+00 0.00E+00 0.00E+00 Ci 0.00E+00 0.00E+00 0.00E+00 Ci 0.00E+00 0.00E+00 0.00E+00 Ci 0.00E+00 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin Page 1 of 3 Friday, February 11, 2022 1:40:0SPM Florida Power & Light St. Lucie Power Plant 4TH Quarter Annual 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/20?2. 13:40 Page 2 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: PSU Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Nuclides Released Units 1STQuarter 2ND Quarter 3RD Quarter A. Fission and Activation Products C-14 Na-24 Be-7 Cr-51 Mn-54 Fe-59 Co-58 Co-60 Ni-63 Ni-65 Zn-65 Sr-91 Y-92 Zr-95 Nb-95 Nb-97 Ru-103 Ag-110m Sb-124 Sb-122 Sb-125 Te-123m Te-129m Te-132 I-131 I-132 Ci Ci 0

Ci Ci 0

Ci Ci Ci Ci 0

Ci Ci Ci 0

0 Ci 0

Ci 0

Ci Ci 0

Ci 0

Ci 3.72E-03 1.64E-03 4.44E-06 2.SBE-05 0.00E+00 7.91E-05 4.36E-05 2.75E-05 1.96E-05 1.37E-04 4.78E-06 0.00E+00 3.03E-04 1.31E-03 7.S0E-04 1.27E-03 9.17E-04 4.80E-04 0.00E+00 8.82E-06 6.27E-06 7.49E-05 2.07E-06 0.00E+00 0.00E+00 0.00E+00 1.12E-05 2.28E-06 2.97E-05 4.43E-05 1.S0E-04 8.73E-05 2.82E-06 0.00E+00 6.83E-05 8.26E-05 1.91E-04 7.97E-04 0.00E+00 2.72E-05 1.SlE-03 6.98E-04 2.43E-06 3.48E-05 O.00E+O0 0.00E+00 0.00E+00 5.80E-05 0.00E+00 1.09E-06 0.00E+00 5.95E-05 If Not Detected, Nudide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 1.38E-03 1.94E-05 1.33E-05 3.53E-04 1.19E-04 7.24E-05 7.56E-04 1.l0E-03 3.28E-04 0.00E+00 5.06E-05 0.00E+00 3.71E-05 3.llE-04 5.23E-04 2.47E-04 0.00E+00 2.12E-04 5.0lE-04 0.00E+00 4.74E-04 0.00E+00 3.91E-04 0.00E+00 0.00E+00 0.00E+00 4TH Quarter Annual 3.41E-04 7.08E-03 1.66E-06 5.13E-05 0.00E+00 9.24E-05 8.84E-05 5.12E-04 1.89E-05 2.95E-04 0.00E+00 7.72E-05 5.77E-04 2.94E-03 2.98E-04 3.42E-03 1.81E-04 1.91E-03 O.00E+00 8.82E-06 0.00E+00 1.32E-04 0.00E+00 2.07E-06 0.00E+00 3.71E-05 2.07E-05 3.45E-04 3.37E-05 6.31E-04 2.48E-05 5.l0E-04 0.00E+00 2.82E-06 2.26E-05 3.86E-04 2.72E-05 1.52E-03 0.00E+DD 2.72E-05 3.52E-05 2.71E-03 0.00E+00 3.73E-05 0.00E+00 3.91E-04 0.00E+00 5.B0E-05 0.00E+00 1.09E-06 0.00E+00 5.95E-05

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:40 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: PSLl Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Nuclides Released Units 1STQuarter 2ND Quarter 3RD Quarter Cs-137 Ci 6.SSE-05 2.0lE-05 0.00E+00 La-140 Ci 0.00E+00 0.00E+00 1.37E-04 W-187 Ci 0.0DE+00 O.0DE+DD 5.96E-06 Total For Period Ci 7.S0E-03 6,96E-03 7.04E-03 B. Tritium H-3 Ci 1.73E+02 1.39E+D2 8.06E+01

c. Dissolved and Entrained Gases Ar-41 0

0.00E+DD 7.41E-DS 0.0DE+0D Kr-85m 0

0.0DE+DD 1.62E-06 0.00E+0D Kr-88 Ci 0.00E+DD 4.41E-06 0.00E+00 Xe-131m Ci 0.00E+0D 0.00E+00 2.SSE-05 Xe-135 Ci O.00E+00 2.25E-05 2.17E-06 Xe-133m 0

0.0DE+00 4.74E-05 2.59E-05 Xe-133 0

3.57E-04 4.0SE-03 4.47E-03 Total For Period Ci 3,57E-04 4.23E-03 4.52E-03 D. Gross Alpha Activity No Nuclides Found 0

0.00E+00 0.00E+0D 0.00E+O0 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter Annual 6.60E-06 9.52E-05 0.00E+00 1.37E-04 0.00E+DD 5.96E-06 1.68E-03 2.35E-02 1.DSE+0l 4.04E+02 0.00E+DD 7.41E-05 0.00E+DD 1.62E-06 0.00E+00 4.41E-06 0.0DE+00 2.SSE-05 1.25E-06 2.60E-05 0.00E+00 7.33E-05 3.12E-05 8.94E-03 3,24E-05 9.15E-03 0.0DE+DD 0.00E+DD

[Server]: PSLSA137 [Database]: NEPSOEMF

_"_EMS Nuclides Released A. Fission and Activation Products No Nuclides Found B. Tritium No Nuclides Found C. Dissolved and Entrained Gases No Nuclides Found D. Gross Alpha Activity No Nuclides Found Reg. Guide 1.21, Table 2B, Liquid Effluents - Continuous Mode Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Continuous Mode Units 1STQuarter 2ND Quarter 3RD Quarter Ci O.OOE+OO O.OOE+OO O.OOE+OO Ci O.OOE+OO O.OOE+OO O.OOE+OO Ci O.OOE+OO O.OOE+OO O.OOE+OO Ci O.OOE+OO O.OOE+OO O.OOE+OO If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin Page 1 of 3 Friday, February 11, 2022 1:40:47PM Florida Power & Light St. Lucie Power Plant 4TH Quarter Annual O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13 :40 Page 2 of 3 Nuclides Released A, Fission and Activation Products C-14 Na-24 Be-7 Cr-51 Mn-54 Fe-59 Co-58 Co-60 Ni-63 Ni-65 Zn-65 Sr-91 Y-92 Zr-95 Nb-95 Nb-97 Ru-103 Ag-110m Sb-124 Sb-122 Sb-125 Te-123m Te-129m Te-132 I-131 I-132 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Units 1STQuarter 2ND Quarter 3RD Quarter Ci 3.72E-03 1.64E-03 1.38E-03 Ci 4.44E-06 2.58E-05 1.94E-05 Ci 0.00E+00 7.91E-05 1.33E-05 Ci 4.36E-05 2.75E-05 3.53E-04 Ci 1.96E-05 1.37E-04 1.19E-04 Ci 4.78E-06 0.00E+00 7.24E-05 Ci 3.03E-04 1.31E-03 7.56E-04 Ci 7.S0E-04 1.27E-03 1.lOE-03 Ci 9.17E-04 4.B0E-04 3.28E-04 Ci 0.00E+00 8.82E-06 0.00E+00 Ci 6.27E-06 7.49E-05 5.06E-05 Ci 2.07E-06 0.00E+00 0.00E+00 Ci 0.00E+00 0.00E+00 3.71E-05 Ci 1.12E-05 2.28E-06 3.11E-04 Ci 2.97E-05 4.43E-05 5.23E-04 Ci 1.S0E-04 8.73E-05 2.47E-04 Ci 2.82E-06 0.00E+00 0.00E+00 Ci 6.83E-05 8.26E-05 2.12E-04 Ci 1.91E-04 7.97E-04 5.0lE-04 Ci 0.00E+00 2.72E-05 0.00E+00 Ci 1.SlE-03 6.98E-04 4.74E-04 Ci 2.43E-06 3.48E-05 0.00E+00 Ci 0.00E+00 0.00E+00 3.91E-04 Ci 0.00E+00 5.80E-05 0.O0E+00 Ci 0.00E+00 1.09E-06 0.00E+00 Ci 0.00E+00 5.95E-05 0.00E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter Annual 3.41E-04 7.0BE-03 1.66E-06 5.13E-05 0.00E+00 9.24E-05 8.84E-05 5.12E-04 1.89E-05 2.95E-04 0.00E+00 7.72E-05 5.77E-04 2.94E-03 2.98E-04 3.42E-03 1.81E-04 1.91E-03 0.00E+00 8.82E-06 0.00E+00 1.32E-04 0.00E+00 2.07E-06 0.00E+00 3.71E-05 2.07E-05 3.45E-04 3.37E-05

.6.31E-04 2.48E-05 5.lOE-04 0.00E+00 2.82E-06 2.26E-05 3.86E-04 2.72E-05 1.52E-03 0.00E+00 2.72E-05 3.52E-05 2.71E-03 0.00E+00 3.73E-05 0.00E+00 3.91E-04 0.00E+00 5.B0E-05 0.00E+00 1.09E-06 0.00E+00 5.95E-05

[Server]: PSLSA137 [Database]: NEPSOEMF

Florida Power & Light, St. Lucie Power Plant 2/11/2022 13:40 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents-Batch Mode Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Batch Mode Nuclides Released Units lSTQuarter 2ND Quarter 3RD Quarter Cs-137 Ci 6.85E-05 2.0lE-05 0.00E+00 La-140 Ci 0.00E+00 0.00E+O0 1.37E-04 W-187 Ci 0.00E+00 0.00E+00 5.96E-06 Total For Period Ci 7.S0E-03 6.96E-03 7.04E-03 B. Tritium H-3 Ci 1.73E+02 1.39E+02 8.06E+0l

c. Dissolved and Entrained Gases Ar-41 Ci 0.00E+00 7.41E-05 0.00E+00 Kr-85m Ci 0.00E+00 1.62E-06 0.00E+00 Kr-88 Ci 0.00E+00 4.41E-06 0.00E+00 Xe-13lm Ci 0.00E+O0 0.00E+00 2.88E-05 Xe-135 Ci 0.00E+00 2.25E-05 2.17E-06 Xe-133m Ci 0.00E+00 4.74E-05 2.59E-05 Xe-133 Ci 3.57E-04 4.08E-03 4.47E-03 Total For Period Ci 3.57E-04 4.23E-03 4.52E-03 D. Gross Alpha Activity No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: admin 4TH Quarter Annual 6.60E-06 9.52E-05 0.00E+00 1.37E-04 0.00E+00 5.96E-06 1.GSE-03 2.35E-02 1.08E+01 4.04E+02 0.00E+00 7.41E-05 0.00E+00 1.62E-06 0.00E+00 4.41E-06 0.00E+00 2.88E-05 1.25E-06 2.60E-05 0.00E+00 7.33E-05 3.12E-05 8.94E-03 3.24E-05 9.15E-03 0.00E+00 0.00E+00

[Server]: PSLSA137 [Database]: NEPSOEMF

TABLE3.2 SOLID WASTE STORAGE AND SHIPMENTS (10 PAGES)

L-2022-023 Enclosure

WMG Suite 9.5.2 Reg Guide Report Report Date: 02/09/2022 NRC Regulatory Guide 1.21 Report

),

  • -z Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From: 01/01/2021 to 12/31/2021 Major Nuclldes for the Above Table:

J' H-3, Be-7, C-14, Cr-51, Mn-54, Fe-55, Co-58, Co-60, Ni-63, Zr-95, Nb-95, Tc-99, 1-129, Cs-137, Am-241, Cm-243 Major Nuclides for the Above Table:

Page 1 of 2

WMG Suite 9.5.2 Reg Guide Report Report Date: 02/09/2022 NRC Regulatory Guide 1.21 Report Solid Waste Shipped Offslte for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From: 01/01/2021 to 12/31/2021 Major Nuclides for the Above Table:

H-3, Be-7, C-14, Cr-51, Mn-54, Fe-55, Co-58, Co-60, Ni-59, Ni-63, Sr-90, Zr-95, Nb-95, Tc-99, Ag-110m, Sb-125, 1-129, Cs-134, Cs-137, Pu-238, Pu-239, Pu-241, Am-241, Cm-242, Cm-243 Page 2 of 2

WMG Suite 9.5.2 Reg Guide Activity Report Report Date: 02/09/2022 NRG Regulatory Guide 1.21 Activity Report Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Shipment, Package, and Category During Period From: 01/01/2021 to 1.2/31/2021 Percent Cutoff: 1.0%

Activity (Cl)

........ ~;-._,..,..... =--....,_~--= ~,,---,-.-.~--'-',_=_..,,., --..L--.~-,j~...,_~,.,_-,..,,..,...........,..,........,---,--

~~~-- _ "---' _ ---~---"- -~-~-=----

    • --*=

_,, ___ 5.9~~L ~.... ~~--- -~.a~~~1 Cr-~---****~---..,-.--**

.., -~-.,--***~~~94~L_.. _,, __

____ 2.39E-01_

Fe-55 33.33%

2.71E+00

  • c;~w-**** *-*-*-* *........ ____ [_"-~~.... _

.. -**"-~ -~3~72% -*-* ---~-

  • _ *--~----~-i*o3&0'1 Co-60 38.19%

3.11 E+00

~~**~*-*-..----.,,-- ***----***r*---------* **,,----,-

Ni*63

5. 77%
4. 70E-01 Zr-95--**~~--~~

.. *--~---~~~-----*"*2.14%1 *-~-~* --* --1.74E-01 Nb-95 3.93%1 3.20E-01

'.".':-\~~iuf~~~,-:,,i'

~~:ldeNam~-*. __. f=----

Abu::::

--~-**-

~~::I:::~

~***

.. '""~~-. **~***1- ____..... -~--..

_.,.... -.--.--*.... _..,,.~-*-*

C-14 1.06%

1.91 E-01

~---~-.-----

Cr-51

/

8.51%

1.53E+00

~::... *---------~-T. __.....

1 :::::1----- --~u.. : -

2~~::~~~

c~-eo ----~==--~~ _** -l _ -_:~3a.23*t=- - ~~

M2E_:EO

~~:-~~:******* =:_t=*:~* *

.*~.*--11:~}~**=-*-**-i-f ;ii

?s-137-: -

_I

~--

-___________ 3.51%r __

- _________ 6.32E-01

WMG Suite 9,5.2 Reg Gulde Activity Report Report Date: 02/09/2022 NRC Regulatory Guide 1.21 Activity Report Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Shipment, Package, and Category During Period From: 01/01/2021 to 12/31/2021 Percent Cutoff: 1.0%

Fe-55 5.03%

2.96E+01 Co-60 15.21%

8.94E+01 rNi -* __ -. _ _ - -- --__ - - -

_ 66.34°/4 -. -__________ 3:90E+O:Z

[cs-137 11.57%

6.80E+01 w..a.~!~pi~-~~,'p.(:*/,*;~\0\,;i.:;;%~;:*o(i,:'.i:t;\(,;;i?;~./;:,_*- _

!Nucl~~~ Nam~________

_ -------------~~undan°.~ ~-*---

___.. ------~c~C1)

C-14 16.02%

1.57E+00

  • ---~---.,,~--.....,,~- --~. -..., -"'=-~---*~~........,,,,.-_ _,,,_ __ ~-...---.-~--

... _. ____,_, ~,_.._ __,..,,,..... __ ~--

Mn-54 1.28%

1.25E-01 1.99%

1.94E-01 Co-60 61.31%

6.00E+00 Nl-63 11.73°Eo 1.15E+00

. -.,-~_,__-~-----~---

  • ~----,-~----

~

Nb-95 2.32%

2.27E-01


----------* --.~*..--.------~-----------**** ~----~---.-**--*~---**----*-*

Ag-110m 2.54%

2.49E-01 s-b~1-2i3---- ~..... ~-- --- ***--

,~~--- ---*---~---.,. -~~------~-----.. **-;*.*1-6*%1 **-- **---~--~----** -*.. ~~*r13E-01 Nuclide Name C-14 Co-60 Nuclide Name C-14 Abundance Activity (Cl) 3.04%

2.68E+00

---~**----~-.,,........_....,_,.~-=-----~-~-,,

17.08%

1.51E+01 Abundance Activity (Cl) 1.11%

7.84E+00

WMG Suite 9.5.2 Reg Gulde Activity Report Report Date: 02/09/2022 NRG Regulatory Guide 1.21 Activity Report Solid Waste Shipped Off site for Disposal and Estimates of Major Nuclides by Shipment, Package, and Category During Period From: 01/01/2021 to 12/31/2021 Percent Cutoff: 1.0%

Nuclide Name Abundance Activity (Ci)

H-3 5.97%

1.56E+00

-~--***--

.. --.,., *~--~*.*-, ~-----<,~~- ~

  • -** ---*"-~(". *--**-.. ~

--~~**.

Cr-51 6.77%1 1.77E+00

~ " -~~ -*=JlL.. --~-* ~-J;~~tL*.... ~9~;.~

Co-60 36.84%

9.63E+00

_ _,_,_.,......._....,._.........=--*.,..,~-..... _............... ~_,__.,. ~---,-----,----*-- --~---~-~~ _____ _._..,_

............,_. ~

Ni-63 5.22%

-~- 1.36E+00 Zr-95 4.25°/i_

1.11E+00 Nb-95 1

.. 7.82~[

2.04E+00 Ag~~1o~*-=-=~-* __.. *.

".*. ___ _,.. _____ 1.97%1

. --~-* 5.. 16E-01

~-~=~* --.

--.~--~* *--**~-----*--*. A1mndance!. _ -**"*--~. ~-~*-.-~--

Fe-55 5.03%

2.96E+01 ec;~ -=-~=~*~-_: *

~L_:*:~~:,--~-=1~_31*% ~-=-:= *

-~-8*+01 Nl-63

[--

66.34%

3.90E+02

  • c~:13i.
  • ---~.
  • 1-* ***--- ****---. 11.61% **--

-.. 6.80E+o1 jwa,s,t~.C.J.~~\;~g,/:;~***>):.*i:,~;:;;):i(;(\\\\\;::\:/i;;J\:i::9:;:.;,\::*:;:;?s-::;;/,::*;y,:,)'./:L:\'i\:.::;);~}j;\l0:i~]/;GS[:f;~li;:wy

~:~~Nam, _..... __ t _.. _ _

Ab;;:;~/ _.. _. -* ___ ~~;;!:+(:~

~::--*-.**-.~--** ~*.. ~-F*-*--~::::~E~.-~~.-::~::

~:~:o -._* : __._-~**--- b--------~t~:~t-*--*--

~:~~::~~

INb-~ =-=~=~-*~ **--=~.=~~---~~1-~ ~~~=*** -

2.2~E~01 l,\g-110m I

2.54%

2.49E-01 1--~-~-~----~---~**--*--***-*-** ***-- i-~---**"~----,.-~-~

Sb-125 1.16%j 1.13E-01

r;..:

~~~ll~e~----.~. ______ ~-.-,.--. --~-**" !:11i"'dance[~. ~.*-*------Activity (Cl)

C-14 3.04%1 2.68E+00

,.;...:....:.,.,.*.,:,.A=U_,..., ___.,. ___,_.,.....,__,.,. __ -=.......;.:..:....i...c*.

,..____,_....,........,...-~-------~---

___,._, _ _z..;_.,.,_,_,_,.

~*~-~.., **.,,,....:.., ____

  • *.,.. -....:,~----.* **., *. * *--**--
        • ::ct Co-60 17.08%1 1.51E+01 Ni~63. ------~-----*-***--t--~~-------~~.75.96%r--~-~-----~1E+01 r~*~**=-~-~~-:-~ *

~-,,-~.:-~-~-~---*=:* _

__1.e1_i1ol*' ---~-:~*****_* ~~-~41~+0_~

Cs-137 1.03~

9.06E-01

_, _____ -------** _ __._ \,---**--** __,.

    • --'---~---*----, ------*. -----**** ---

WMG Suite 9,5.2 Reg Guide Activity Report Report Date: 02/09/2022 NRC Regulatory Guide 1.21 Activity Report Solid Waste Shipped Offslte for Disposal and Estimates of Major Nuclides by Shipment, Package, and Category During Period From: 01/01/2021 to 12/31/2021 Percent Cutoff: 1.0%

fl\.

Nuclide Name Co-60 Ni-63 Abundance 1.1%

5,07%

Activity (Ci) 7,85E+00

  • 16.87%1...

. 1.20E~ci2

. *----- *-~--** ~----. '1**--*"* --~---***--~. ~** ~

64.54%

4,59E+02

--~--~***.,. "". 9~7o/~t... "::~:~*-c~~- ____ 6

.. 95~io1

WMG Suite 9.5.2 Reg Guide Report Report Date: 02/09/2022 During Period From: 01/01/2021 to 12/31/2021 Total Shipments by Carrier Number of Shipments per each carrier

WMG Suite 9.5.2 Report date: 2/9/2022 NRG Regulatory Guide 1.21 Report Shipment and Package Summary Solid Waste Shipped Offslte for Disposal During Period from: 1/1/2021 to 12/31/2021 4/16/2021 FPUPSL 21M EnergySolutio 032 ns Bear Creek 5/3/2021 FPL/PSL 21M EnergySolutio 037 ns Bear Creek 5/6/2021 FPL/PSL 21M Erwin 043 ResinSolutio Page 1 of 3

WMG Suite 9.5.2 Report date: 2/9/2022 NRG Regulatory Guide 1.21 Report Shipment and Package Summary Solid Waste Shipped Offsite for Disposal During Period from: 1/1/2021 to 12/31/2021 Page 2 of 3

WMG Suite 9.5.2 Report date: 2/9/2022 NRG Regulatory Guide 1.21 Report Shipment and Package Summary Solid Waste Shipped Offsite for Disposal During Period from: 1/1/2021 to 12/31/2021 12/1/2021 FPL/PSL 21-110 Bear Cree 12/29/2021 FPL/PSL 21 -

EnergySolutio 123 ns Bear Creek Page 3 of 3

TABLE3.3 DOSE ASSESSMENTS (27 PAGES)

L-2022-023 Enclosure


~,

/

~,_EMS Eiluem.lvl.m.,gi:rru."lJt So+/-tw:;m.:

Page 1 of 1 Friday, February 11, 2022 2:50:l?PM Florida Power & Light St. Lucie Power Plant Organ Dose Bone Limit Percent of Limit Liver Limit Percent of Limit Tota[ Body Limit Percent of Limit Thyroid Limit Percent of Limit Kidney Limit Percent of Limit Lung Limit Percent of Limit GI-Ui Limit Percent of Limit User: admin Reg. Guide 1.21, App B, Sec Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem 1STQuarter 1.42E-03 l.23E-03 1.23E-03 1.23E-03 1.77E-04 1.23E-03 1.23E-03 2ND Quarter 1.16E-03 1.l0E-03 1.l0E-03 1.llE-03 1.89E-04 1.lOE-03 1.lOE-03 3RD Quarter 1.21E-03 1.l0E-03 1.l0E-03 1.l0E-03 1.76E-04 1.l0E-03 1.l0E-03 4TH Quarter 1.46E-03 1.28E-03 1.28E-03 1.28E-03 1.91E-04 1.28E-03 1.28E-03 Annual 5.25E-03 4.71E-03 4.71E-03 4.72E-03 7.34E-04 4.?lE-03 4.71E-03

[Server]: PSLSA137 [Database]: NEPSOEMF

,:_,,,,,*-::, EMS-

,1

,l"

1

'r...,-,- -;_ p.,_~:....

Bl1u~nt M:mag,.:rru:nc Sofrw:m:

Page 1 of 1 Friday, February 11, 2022 2:48:40PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: PSL1 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Organ Dose Units 1STQuarter 2ND Quarter Bone mRem 7.25E-04 4.20E-04 Limit mRem Percent of Limit Liver mRem 6.28E-04 4.73E-04 Limit mRem Percent of Limit Total Body mRem 6.28E-04 4.73E-04 Limit mRem Percent of Limit Thyroid mRem 6.30E-04 4.79E-04 Limit mRem Percent of Limit Kidney mRem 9.13E-05 1.0lE-04 Limit mRem Percent of Limit Lung mRem 6.28E-04 4.73E-04 Limit mRem Percent of Limit GI-Ui mRem 6.28E-04 4.73E-04 Limit mRem Percent of Limit User: admin 3RD Quarter 7.43E-04 6.60E-04 6.60E-04 6.60E-04 1.0lE-04 6.60E-04 6.60E-04 4TH Quarter Annual 7.20E-04 2.61E-03 6.46E-04 2.41E-03 6.46E-04 2.41E-03 6.46E-04 2.42E-03 1.0lE-04 3.94E-04 6.46E-04 2.41E-03 6.46E-04 2.41E-03

[Server]: PSLSA137 [Database]: NEPSOEMF

Organ Dose Bone Limit Percent of Limit Liver Limit Percent of Limit Total Body Limit Percent of Limit Thyroid Limit Percent of Limit Kidney Limit Percent of Limit Lung Limit Percent of Limit GI-Lli Limit Percent of Limit User: admin

EMS, Page 1 of 1 Friday, February 11, 2022 2:49:27PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem lSTQuarter 6.98E-04 6.00E-04 6.00E-04 6.0lE-04 8.58E-05 6.00E-04 6.00E-04 2ND Quarter 7.36E-04 6.27E-04 6.27E-04 6.28E-04 8.85E-05 6.27E-04 6.27E-04 3RD Quarter 4.68E-04 4.42E-04 4.42E-04 4.42E-04 7.S0E-05 4.42E-04 4.42E-04 4TH Quarter Annual 7.41E-04 2.64E-03 6.36E-04 2.30E-03 6.36E-04 2.30E-03 6.36E-04 2.31E-03 9.09E-05 3.40E-04 6.36E-04 2.30E-03 6.36E-04 2.30E-03

[Server]: PSLSA137 [Database]: NEPSOEMF

"'7 *. *-*"*EMS

,\

I

_,:._ -~...

E}1u-::, IvL:mag::ment Soft-.\~tre NG Dose Gamma Air Limit Percent of Limit Beta Air Limit Percent of Limit NG Total Body Limit Percent of Limit NG Skin Limit Percent of Limit User: admin Reg. Guide 1.21, App B, Sec Air Doses Due To Gaseous Releases Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units lSTQuarter 2ND Quarter mRad 2.62E-04 5.l0E-04 mRad mRad 1.06E-04 l.91E-04 mRad mRem 2.49E-04 4.82E-04 mRem mRem 3.75E-04 7.14E-04 mRem 3RD Quarter 1.09E-03 4.64E-04 1.03E-03 1.53E-03 Page 1 of 1 Friday, February 11, 2022 2:56:54PM Florida Power & Light St. Lucie Power Plant 4TH Quarter 2.95E-04 6.33E-04 2.52E-04 6.25E-04 Annual 2.15E-03 1.39E-03 2.0lE-03 3.25E-03

[Server]: PSLSA137 [Database]: NEPSOEMF

___ EMS.

NG Dose Gamma Air Limit Percent of Limit Beta Air Limit Percent of Limit NG Total Body Limit Percent of Limit NG Skin Limit Percent of Limit User: admin Reg. Guide 1.21, App B, Sec Air Doses Due To Gaseous Releases Unit: PSL1 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units mRad mRad mRad mRad mRem mRem mRem mRem 1STQuarter 1.54E-04 5.94E-05 1.47E-04 2.19E-04 2ND Quarter 9.86E-05 5.?0E-05 9.33E-05 1.S0E-04 3RD Quarter 1.31E-04 4.74E-05 1.25E-04 1.83E-04 Page 1 of 1 Friday, February 11, 2022 2:55:40PM Florida Power & Light St. Lucie Power Plant 4TH Quarter 1.29E-04 4.61E-05 1.23E-04 1.79E-04 Annual 5.13E-04 2.10E-04 4.87E-04 7.31E-04

[Server]: PSLSA137 [Database]: NEPSOEMF

EMS NG Dose Gamma Air Limit Percent of Limit Beta Air Limit Percent of Limit NG Total Body Limit Percent of Limit NG Skin Limit Percent of Limit User: admin Reg. Guide 1.21, App B, Sec Air Doses Due To Gaseous Releases Unit: PSL2 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units mRad mRad mRad mRad mRem mRem mRem mRem 1ST Quarter 1.0BE-04 4.69E-05 1.03E-04 1.55E-04 2ND Quarter 4.llE-04 1.34E-04 3.89E-04 5.64E-04 3RD Quarter 9.55E-04 4.16E-04 9.03E-04 1.35E-03 Page 1 of 1 Friday, February 11, 2022 2:56:21PM Florida Power & Light St. Lucie Power Plant 4TH Quarter Annual 1.66E-04 1.64E-03 5.87E-04 1.18E-03 1.29E-04 1.52E-03 4.46E-04 2.52E-03

[Server]: PSLSA137 [Database]: NEPSOEMF

EMS E:l:1111:t Jvfa:r1.1g::m~nt Sofu,,,;ir-c Organ Dose Bone Limit Percent of Limit Liver Limit Percent of Limit Total Body Limit Percent of Limit Thyroid Limit Percent of Limit Kidney Limit Percent of Limit Lung Limit Percent of Limit GH!i Limit Percent of Limit User: admin Reg. Guide 1.21, App B, Sec Doses to a member of the public due to Liquid Releases Unit: Site Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem mRem 1STQuarter 2.27E-03 2.70E-03 2.62E-03 2.31E-03 2.76E-03 3.67E-03 6.49E-03 2ND Quarter 1.73E-03 3.56E-03 2.90E-03 1.85E-03 3.18E-03 2.54E-03 8.91E-03 3RD Quarter 1.54E-03 2.82E-03 2.10E-03

  • 1.13E-03 2.02E-03 1.96E-03 4.20E-02 Page 1 of 1 Friday, February 11, 2022 3:11:11PM Florida Power & Light St. Lucie Power Plant 4TH Quarter Annual 3.19E-04 5.85E-03 1.90E-04 9.28E-03 2.20E-04 7.83E-03 1.27E-04 5.41E-03 1.44E-04 8.11E-03 1.52E-04 8.32E-03 2.56E-03 6.00E-02

[Server]: PSLSA137 [Database]: NEPSOEMF

  • -.~*,,EMS,

_,\-,_

E}]m:ot lvL1J1..1!;-Cm-:.-i1c So+/-i:>.varc Organ Dose Bone Limit Percent of Limit Liver Limit Percent of Limit Total Body Limit Percent of Limit Thyroid Limit Percent of Limit Kidney Limit Percent of Limit Lung Limit Percent of Limit GI-Ui Limit Percent of Limit User: admin Reg. Guide 1.21, App B, Sec Doses to a member of the public due to Liquid Releases Unit: PSL1 Starting: 1-Jan-2021 Ending: 31-Dec-2021 Units 1STQuarter 2ND Quarter 3RD Quarter mRem 1.13E-03 8.64E-04 7.68E-04 mRem mRem l.35E-03 1.78E-03 1.41E-03 mRem mRem 1.31E-03 1.45E-03 1.0SE-03 mRem mRem 1.16E-03 9.24E-04 5.63E-04 mRem mRem l.38E-03 l.59E-03 1.0lE-03 mRem mRem 1.83E-03 l.27E-03 9.S0E-04 mRem mRem 3.25E-03 4.46E-03 2.l0E-02 mRem Page 1 of 1 Friday, February 11, 2022 2:57:37PM Florida Power & Light St. Lucie Power Plant 4TH Quarter Annual l.59E-04 2.92E-03 9.52E-05 4.64E-03 1.l0E-04 3.92E-03 6.33E-05 2.71E-03 7.22E-05 4.0SE-03 7.61E-05 4.16E-03 l.28E-03 3.00E-02

[Server]: PSLSA137

[Database]: NEPSOEMF

~-EMS Efl:IU".:t Jvlm~rru:m.So+/-h,~tri:

Organ Dose Bone Limit Percent of Limit Liver Limit Percent of Limit Total Body Limit Percent of Limit Thyroid Limit Percent of Limit Kidney Limit Percent of Limit Lung Limit Percent of Limit GI-Lli Limit Percent of Limit User: admin Reg. Guide 1.21, App B, Sec Doses to a member of the public due to Liquid Releases Unit: PSL2 starting: 1-Jan-2021 Ending: 31-Dec-2021 Units 1STQuarter 2ND Quarter mRem 1.13E-03 8.64E-04 mRem mRem 1.35E-03 1.78E-03 mRem mRem 1.31E-03 1.45E-03 mRem mRem l.16E-03 9.24E-04 mRem mRem 1.38E-03 1.59E-03 mRem mRem 1.83E-03 l.27E-03 mRem mRem 3.25E-03 4.46E-03 mRem 3RD Quarter 7.68E-04 1.41E-03 1.0SE-03 5.63E-04 l.0lE-03 9.80E-04 2.lOE-02 Page 1 of 1 Friday, February 11, 2022 2:58:12PM Florida Power & Light St. Lucie Power Plant 4TH Quarter Annual 1.59E-04 2.92E-03 9.52E-05 4.64E-03 l.lOE-04 3.92E-03 6.33E-05 2.71E-03 7.22E-05 4.0SE-03 7.61E-05 4.16E-03 1.28E-03 3.00E-02

[Server]: PSLSA137 [Database]: NEPSOEMF

Liquid Status Summary Report Period:

Ann, 2021

~

~

Xe-135 N

Kr-85m N

Ar-41 N

Xe-133 N

Xe-131m N

Xe-133m N

Kr-88 N

Nuclide Type Total

~

~

Ni-63 0

H-3 0

C-14 0

Nuclide Type Total

~

~

Ni-65 p

Sb-122 p

Te-129m p

Cs-137 p

Te-132 p

Sb-125 p

Sr-91 p

Y-92 p

Nb-97 p

Sb-124 p

W-187 p

Co-58 p

Be-7 p

Zn-65 p

User: admin Actiyjty CuCj) 5.193E+01 3.250E+OO 1.481E+02 1.788E+04 S.752E+01 1.466E+02 8.821E+OO 1.829E+04 Activity CuCD 3.812E+03 8.076E+08 1.417E+04 8.077E+08 Activity CuCj) 1.764E+Ol 5.450E+01 7.818E+02 1.905E+02 1.160E+02 S.426E+03 4.146E+OO 7.425E+Ol l.019E+03 3.033E+03 1.191E+Ol 5.884E+03 1.848E+02 2.636E+02 Site/Unit/Discharge Point:

Avg Cone CuCi /ml) 2.432E-10 1.522E-11 6.937E-10 8.374E-08 2.694E-10 6.868E-10 4.131E-11 8,569E-08 Avg Cone CuCi /ml) 1.785E-08 3.783E-03 6.637E-08 3.783E-03 Ayg cone CuCj/mL) 8.261E-11 2.553E-10 3.662E-09 8.921E-10 5.431E-10 2.542E-08 1.942E-11 3.478E-10 4.773E-09 1.420E-08 5.581E-11 2.756E-08 8.655E-10 1.23SE-Q9 Friday, February 11, 2022 15:01 Site Ayg Cone/10xECL 1.216E-07 7.611E-09 3.469E-07 4.187E-05 l.347E-07 3.434E-07 2.066E-08 4.284E-05 Ayg Cone/10xECL 1.785E-05 3.783E-01 2.212E-04 3.785E-01 Ayg Cone/10xECL 8.261E-08 2.553E-06 5.231E-05 8.921E-05 6.035E-06 8.472E-05 9.710E-08 8.695E-07 1.591E-06 2.029E-04 l.860E-07 1.378E-04 O.OOOE+OO 2.469E-05 PU Cone <uCj/mL) 9.156E-14 5.730E-15 2.612E-13 3.152E-11 1.014E-13 2.SSSE-13 1.SSSE-14 3.226E-11 PU cone <uCi 1ml) 6.721E-12 1.424E-06 2.498E-11 1.424E-06 Pil Cone fuCi /ml) 3.llOE-14 9.609E-14 1.378E-12 3.358E-13 2.045E-13 9.568E-12 7.311E-15 1.309E-13 1.797E-12 5.347E-12 2.lOlE-14 1.037E-11 3.258E-13 4.648E-13 Page4 of 6 Pil Cone/10xECL 4.578E-11 2.865E-12 1.306E-10 1.576E-08 S.071E-11 1.293E-10 7.776E-12 1.613E-08 Pi) Conel10xECL 6.721E-09 1.424E-Q4 8.328E-Q8 1.425E-04 Pil Conc/1QxECL 3.llOE-11 9.609E-10 1.969E-08 3.358E-08 2.272E-09 3.189E-08 3.655E-11 3.273E-10 S.989E-10 7.639E-08 7.003E-11 5.187E-08 O.OOOE+OO 9.296E-09

[Server]: PSLSA137 [Database]: NEPSOEMF

Liquid Status Summary Report Friday, February 11, 2022 15:01 Page 5 of6 Period:

Ann, 2021 Site/Unit/Discharge Point:

Site

~

~

Agi:llit¥ (uCil A:lt'.9 Cs:mi:; (uCi lmL)

A:ll9 Cs:ms;;ll!:!xECL

~ii Cs:ms;; (uCilmL)

~ii CQas;;ll!:!xECL Mn-54 p

5.897E+02 2.762E-09 9.207E-06 1.040E-12 3.466E-09 Ag-llOm p

7.719E+02 3.615E-D9 6.025E-05 1.361E-12 2.268E-Q8 Ru-103 p

5.632E+OO 2.638E-11 8.793E-08 9.931E-15 3.310E-11 Cr-51 p

1.024E+03 4.798E-09 9.596E-07 l.B06E-12 3.612E-10 Fe-59 p

1.545E+02 7.234E-10 7.234E-06 2.723E-13 2.723E-09 Co-60 p

6.836E+03 3.202E-OB l.067E-03 1.205E-11 4.0lBE-07 Nb-95 p

1.262E+03 5.909E-09 l.970E*OS 2.224E-12 7.415E-09 La-140 p

2.747E+02 1.287E-09 l.430E-05 4.844E-13 5.3B2E-09 Te-123m p

7.450E+Ol 3.490E-10 O.OOOE+OO 1.314E-13 O.OOOE+OO Na-24 p

1.026E+02 4.804E-10 9.608E-07 l.809E-13 3.617E-10 Zr-95 p

6.895E+02 3.230E-09 1.615E-05 1.216E-12 6.079E-09 Nuclide Type Total 2.885E+04 1.351E-07 1.799E-03 5.086E-11 6.773E-07

~

~

AgMt¥ (uCil Avg CQas;; (uCilmL)

Avg CQas;;ll!:!xECL

~ii CQDC (uCi lmL)

~ii CQacll!:!xECL I-131 R

2.183E+OO 1.023E-11 1.023E-06 3.BSOE-15 3.BSOE-10 I-132 R

1.190E+02 5.573E-10 S.573E-07 2.098E-13 2.098E-10 Nuclide Type Total 1.212E+02 5.675E-10 1.SSOE-06 2.136E-13 5.948E-10 Total S.077E+08 3.783E*D3 3.8D4E-01 1.424E*D6 1.432E-04 User: admin

[Server]: PSLSA137

[Database]: NEPSOEMF

Liquid Status Summary Report Period:

Ann, 2021 Site/Unit/Discharge Point:

Liquid Dose Summary - Note: All Doses in mRem Receptor Liquid Receptor - Teenager Liquid Recptor - Child Maximum Dose by Organ:

Agegrouo Teenager Child Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

User: admin fume.

5.848E-03 3.553E-03 S.848E-03 S.998E-02 7.834E-03 Liver 9.281E-03 6.901E-03 9.281E-03 Friday, February 11, 2022 15:01 Site Total Body 7.834E-03 6.659E-03 7.834E-03 Thyroid 5.414E-03 S.OOSE-03 S.414E-03

.Ki.d.MY 8.108E-03 3.538E-03 8.lOBE-03

.Y!!19.

8.323E-03 6.2SSE-D3 8.323E-03 Page 6 of 6 GI-LH S.998E-02 2.549E-02 5.998E-D2 Skin O.OOOE+OO O.OOOE+OO O.OOOE+OO

[Server]: PSLSA137 [Database]: NEPSOEMF

Liquid Status Summary Report Period:

Ann, 2021

~

~

Xe-135 N

Kr-88 N

Ar-41 N

Xe-131m N

Xe-133 N

Xe-133m N

Kr-85m N

Nuclide Type Total

~

~

Ni-63 0

H-3 0

C-14 0

Nuclide Type Total

~

~

Co-60 p

Se-7 p

Zr-95 p

Zn-65 p

Cr-51 p

Y-92 p

Sb-124 p

Ru-103 p

Nb-95 p

La-140 p

Na-24 p

Sr-91 p

Ag-llOm p

Cs-137 p

User: admin Actiyity (ucn 2.596E+01 4.410E+OO 7.406E+01 2.876E+01 8.939E+03 7.332E+01 1.625E+OO 9.147E+03 Activity (uCj) 1.906E+03 4.038E+08 7.085E+03 4.038E+08 Activity (uCD 3.418E+03 9.239E+Ol 3.448E+02 1.318E+02 5.122E+D2 3.713E+Ol l.516E+03 2.816E+OO 6.308E+02 1.374E+D2 5.128E+Ol 2.073E+OO 3.859E+02 9.523E+Ol Site/ Unit/Discharge Point:

Ayg Cone (uCj/mL) 2.432E-10 4.131E-11 6.937E-10 2.694E-10 8.374E-08 6.868E-10 1.522E-11 S.569E-08 Avg Cone (uCi[roll 1.785E-08 3.783E-03 6.637E-08 3.783E-03 Avg Cone CuCi /ml) 3.202E-08 8.655E-10 3.230E-09 1.235E-09 4.798E-09 3.478E-10 1.420E-08 2.638E-11 5.909E-09 1.287E-09 4.804E-10 1.942E-11 3.615E-09 8.921E-10 Friday, February 11, 2022 14:59 PSL1 Ayg Cone/10XECL 1.216E-07 2.066E-08 3.469E-07 1.347E-07 4.187E-05 3.434E-07 7.611E-09 4.284E-05 Avg Cone/1QxECL 1.785E-05 3.783E-01 2.212E-Q4 3.785E-01 Ayg Cone/1QxECL 1.067E-03 O.OOOE+OO 1.615E-05 2.469E-05 9.596E-07 8.695E-07 2.029E*04 8.793E-08 1.970E-05 1.430E-05 9.608E-07 9.710E-08 6.025E-05 8.921E-05 DiJ Cone (uCi/mL) 9.156E-14 1.555E-14 2.612E-13 1.014E-13 3.152E-11 2.585E-13 5.730E-15 3.226E-11 Pil Cone (uCi [roll 6.721E-12 1.424E-06 2.498E-11 1.424E-06 Pil Cone Cuc; /ml) 1.205E-11 3.258E-13 1.216E-12 4.648E-13 1.806E-12 1.309E-13 5.347E-12 9.931E-15 2.224E-12 4.844E-13 1.809E-13 7.311E-15 1.361E-12 3.358E-13 Page4 of 6 Dil Cone/1QxECL 4.578E-11 7.776E-12 1.306E-10 5.071E*11 1.576E-08 1.293E-10 2.865E-12 1.613E*OS PU Cone/1QxECL 6.721E-09 1.424E-04 8.328E-08 1.425E*04 Dj) Cone(10xECL 4.0lSE-07 O.ODOE+OO 6.079E-09 9.296E-09 3.612E-10 3.273E-10 7.639E-08 3.310E-11 7.415E-09 5.382E-09 3.617E-10 3.655E-11 2.268E-08 3.358E-08

[Server]: PSLSA137 [Database]: NEPSOEMF

Liquid Status Summary Report Friday, February 11, 2022 14:59 Page 5 of6 Period:

Ann, 2021 Site/Unit/Discharge Point:

PSLl

~

~

Aci:h£i!:Y: (JJCi)

A)Lg C2ni:: (JJCilmL)

AY..9 C2ni::llOxfCL Dil C2ni:: (JJCilmL)

Dil C2ni::llOxfCL Te-132 p

S.798E+Ol S.431E-10 6.03SE-06 2.04SE-13 2.272E-09 Nb-97 p

S.09SE+02 4.773E-09 1.591E-06 1.797E-12 S.989E-10 Sb-122 p

2.725E+Ol 2.553E-10 2.553E-06 9.609E-14 9.609E-10 Te-129m p

3.909E+02 3.662E-09 S.231E-05 l.378E-12 l.969E-08 Mn-54 p

2.949E+02 2.762E-09 9.207E-06 1.040E-12 3.466E-09 Fe-59 p

7.723E+Ol 7.234E-10 7.234E-06 2.723E-13 2.723E-09 W-187 p

5.957E+OO 5.581E-11 l.860E-07 2.lOlE-14 7.003E-11 Te-123m p

3.725E+Ol 3.490E*10 O.OOOE+OO l.314E-13 O.OOOE+DO Sb-125 p

2.713E+D3 2.542E-08 8.472E-05 9.568E-12 3.189E-08 Co-58 p

2.942E+03 2.756E-08 1.378E-04 1.037E-ll 5.187E-08 Ni-65 p

8.818E+OO 8.261E-11 8.261E-08 3.llOE-14 3.llOE-11 Nudide Type Total 1.442E+04 1.351E-07 1.799E-03 5.086E-11 6.773E-07

~

~

Aci:iY..ity: (JJCi)

Avg C2ni:: (uCilmL)

A)Lg C2ni::llOxfCL Dil CQDC (uCi lmL)

Dil C2ni::llOxfCL I-131 R

1.092E+OO l.023E-11 1.023E-06 3.850E-15 3.BSOE-10 I-132 R

5.949E+Ol 5.573E-10 5.573E-07 2.098E-13 2.098E-10 Nudide Type Total 6.058E+01 5.675E-10 1.SSOE-06 2.136E-13 5.948E-10 Total 4.039E+08 3.783E-03 3.804E-01 1.424E-06 1.432E-04 User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Liquid Status Summary Report Period:

Ann, 2021 Site/Unit/Discharge Point:

Liquid Dose Summary - Note: All Doses in mRem Receptor Liquid Receptor - Teenager Liquid Recptor - Child Maximum Dose by Organ:

Agegroup Teenager Child Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

User: admin fu2ne.

2.924E-03 1.mE-03 2.924E-03 2.999E-02 3.917E-03 Liver 4.640E-03 3.451E-03 4.640E-03 Friday, February 11, 202214:59 PSLl Total Body 3.917E-03 3.329E-03 3.917E-03 Thyroid 2.707E-03 2.503E-03 2.707E-03 1ill!.Dil 4.054E-03 1.769E-03 4.054E-03 1.u!1g 4.162E-03 3.l28E-03 4.162E-03 Page 6 of6 GI-Ui 2.999E-02 1.274E-D2 2.999E-02 Skin O.OOOE+OO O.OOOE+OD O.OOOE+OO

[Server]: PSLSA137 [Database]: NEPSOEMF

Liquid Status Summary Report Period:

Ann, 2021 NYciide.

~

Ar-41 N

Xe-133 N

Kr-85m N

Kr-88 N

Xe-135 N

Xe-133m N

Xe-131m N

Nuclide Type Total NYciide.

~

H-3 0

C-14 0

Ni-63 0

Nudide Type Total NYciide.

~

Co-60 p

La-140 p

Nb-97 p

Sb-124 p

Ru-103 p

Cr-51 p

Te-123m p

Fe-59 p

Cs-137 p

Te-132 p

Sb-122 p

Sb-125 p

Na-24 p

Mn-54 p

User: admin Activity <ucn 7.406E+Ol 8.939E+03 1.625E+OO 4.410E+OO 2.596E+Ol 7.332E+Ol 2.876E+Ol 9,147E+03 Activity Cuen 4.038E+08 7.085E+03 1.906E+03 4.038E+08 Activity <ucn 3.418E+03 1.374E+02 5.095E+02 1.516E+03 2.816E+OO 5.122E+02 3.725E+Ol 7.723E+Ol 9.523E+Ol 5.798E+Ol 2.725E+01 2.713E+03 5.128E+Ol 2.949E+02 Site/Unit/Discharge Point:

Avg Cone <ucj lmLl 6.9371:-10 8.374E-08 1.522E-ll 4.1311:-11 2.432E-10 6.868E-10 2.694E-10 8.569E-08 Avg Cone CuCj/mL) 3.783E-03 6.637E-08 1.785E-08 3.783E-03 Ava cone {uCi /mLl 3.202E-08 1.287E-09 4.773E-09 1.420E-08 2.638E-11 4.798E-09 3.4901:-10 7.234E-10 8.921E-10 5.4311:-10 2.5531:-10 2.542E-08 4.804E-10 2.762E-09 Friday, February 11, 2022 15:00 PSL2 Ayg Cone(10xECL 3.469E-07 4.187E-05 7.6111:-09 2.066E-08 1.216E-07 3.4341:-07 1.347E-07 4.284E-05 Ayg cone/10xECL 3.7831:-01 2.2121:-04 1.785E-05 3.785E*01 Ayg cone/10xECL 1.067E-03 1.430E-05 1.591E-06 2.029E-04 8.793E-08 9.5961:-07 O.OOOE+OO 7.234E-06 8.9211:-05 6.035E*06 2.5531:-06 8.472E-05 9.608E-07 9.207E-06 PU cone <uCi fmLl 2.6121:-13 3.1521:-11 5.730E-15 1.5551:-14 9.1561:-14 2.585E-13 1.014E-13 3.226E-11 PU Cone CuCi /ml) 1.424E-06 2.498E-11 6.7211:-12 1.424E-06 DH Cone (yCj/mL) 1.2051:-11 4.8441:-13 1.7971:-12 5.347E-12 9.931E-15 1.8061:-12 1.3141:-13 2.723E-13 3.3581:-13 2.045E-13 9.6091:-14 9.568E-12 1.809E-13 1.040E-12 Page 4of 6 Pit Cone/10xECL 1.306E-10 1.576E-08 2.865E-12 7.776E-12 4.5781:-11 1.293E-10 5.0711:-11 1.613E-08 PU Cone/1QxECL 1.424E-04 8.328E-08 6.721E-09 1.425E-04 PU Cone/10xECL 4.0lBE-07 5.382E-09 5.989E-10 7.639E-08 3.310E-11 3.6121:-10 O.OOOE+OO 2.723E-09 3.358E-08 2.272E-D9 9.609E*10 3.1891:-08 3.617E-10 3.466E-09

[Server]: PSLSA137 [Database]: NEPSOEMF

Liquid Status Summary Report Friday, February 11, 2022 15:00 Page 5 of6 Period:

Ann, 2021 Site/Unit/Discharge Point:

PSL2 N.u.cikl.e.

~

8gj:v:ib'. (l.lCil Avg C2n~ C:uCilmLl 8:v:g C2n~llOxt;CL Qil C2n~ (1.1CilmLl Qil Con~llOxt;CL Ni-65 p

8.818E+OO 8.261E-11 8.261E-08 3.llOE-14 3.llOE-11 Y-92 p

3.713E+01 3.478E-10 8.695E-07 1.309E-13 3.273E-10 Ag-110m p

3.859E+02 3.615E-09 6.025E-05 1.361E-12 2.268E-08 W-187 p

5.957E+OO 5.581E--11 1.860E--07 2.101E-14 7.003E--11 Zn-65 p

1.318E+02 1.235E--09 2.469E-05 4.648E--13 9.296E-09 Co-58 p

2.942E+03 2.756E--08 1.378E-04 1.037E-11 5.187E--08 Zr-95 p

3-448E+02 3.230E--09 1.615E--05 1.216E--12 6.079E-09 Nb-95 p

6.30BE+02 5.909E--09 1.970E-05 2.224E--12 7.415E-09 Te-129m p

3.909E+02 3.662E-09 5.231E-05 1.378E-12 1.969E-08 Be-7 p

9.239E+01 8.655E-10 0.000E+OO 3.258E-13 O.OOOE+OO Sr-91 p

2.073E+OO 1.942E-11 9.710E-08 7.311E--15 3.655E-11 Nuclide Type Total 1,442E+04 1.351E-07 1.799E-03 5.086E-11 6.773E-07 NY.d.i.d.e.

~

Ai;tMb'. (!.!Cil 8:1£9 C2n~ (1.1CilmLl Avg C2n~llQxt;CL Qil C2n~ (1.1Ci lmL)

Qi! C2n~llQxt;CL 1-132 R

5.949E+01 5.573E-10 5.573E-07 2.098E-13 2.098E--10 I-131 R

1.092E+OO 1.023E-11 1.023E-06 3.850E-15 3.850E-10 Nuclide Type Total 6.058E+01 5.675E-10 1.SSOE-06 2.136E-13 5.948E-10 Total 4.039E+OS 3.783E-03 3.804E:-01 1.424E-06 1.432E-04 User: admin

[Server]: PSLSA137

[Database]: NEPSOEMF

Liquid Status Summary Report Period:

Ann, 2021 Site/Unit/Discharge Point:

Liquid Dose Summary - Note: All Doses in mRem Receptor Liquid Receptor - Teenager Liquid Recptor - Child Maximum Dose by Organ:

Agegroup Teenager Child Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

User: admin

.fume.

2.924E-03 1.mE-03 2.924E-03 2.999E-02 3.917E-03 Liver 4.640E-03 3.451E-03 4.640E-03 Friday, February 11, 2022 15:00 PSL2 Total Body 3.917E-03 3.329E-03 3.917E-03 Thyroid 2.707E-03 2.503E-Q3 2.707E-03

~

4.054E-Q3 1.769E-Q3 4.054E-03 M!!!9.

4.162E-03 3.128E-03 4.162E-03 Page 6 of 6 GI-Ui 2.999E-02 l.274E-Q2 2.999E-02

.skin O.OOOE+OO O.OOOE+OO O.OOOE+OO

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Friday, February 11, 2022 13:22 Page 13 of 15 Period:

Ann, 2021 Site/Unit/ Discharge Point:

Site N.ll.ciid.e.

Tu Aci:i:v:ity (1.1CD A:y:g C1:mt (uCi li::t)

A:v:g C2atllQxl:CL Avg Rel Rate (1.1Cil:zet)

Xe-135 N

2.177E+05 6.073E*ll 8.675E-05 6.904E-03 Xe-135m N

5.471E+OS 1.526E-10 3.814E-04 1.735E-02 Kr-88 N

2.535E+02 7.071E-14 7.857E-07 8.039E-06 Xe-138 N

4.314E+02 1.203E-13 6.016E-07 1.368E-05 Xe-127 N

6.480E+Ol 1.807E-14 O.OOOE+OO 2.0SSE-06 Xe-133 N

1.070E+06 2.983E-10 5.967E-05 3.392E-02 Xe-131m N

1.065E+07 2.971E-09 l.486E-04 3.378E-01 Kr-89 N

1.825E+04 5.090E-12 5.090E-04 5.787E-04 Xe-133m N

1.362E+03 3.798E-13 6.330E-08 4.318E-05 Kr-8Sm N

3.829E+04 1.068E-11 1.068E-05 1.214E-03 Ar-41 N

4.061E+06 1.133E-09 1.133E-02 1.288E-01 Kr-87 N

1.231E+02 3.435E-14 1.717E-07 3.905E-06 Nuclide Type Total 1.661E+07 4.632E-09 1.253E*02 5.266E-01 N.ll.ciid.e.

Tu AttMty (1.1Ci)

A:v:g C2at Cu Ci ltt)

A)lg C2atl1Qxl:CL A)lg Rel Rate (UCi l:zet)

H-3 0

1.175E+07 3.278E-09 3.278E-03 3.726E-01 G-Alpha 0

3.889E-02 1.0SSE-17 1.0SSE-03 1.233E-09 C-14 0

2.0SOE+07 5.718E-09 1.906E-01 6.SOlE-01 Nuclide Type Total 3.225E+07 8.996E-09 1.950E-01 1.023E+OO

~

Iw.e.

Agivity (yCi)

Avg C2ns;; (yCils;;t)

Avg C2ntl1QxEC!,

Avg Rel Ri:!te (yCi l:zes;;)

Cr-51 p

5.095E-01 1.421E-16 4.737E-10 1.616E-08 Co--60 p

2.949E-01 8.224E-17 1.645E-07 9.350E-09 Nb-95 p

2.893E-Ol 8.069E-17 4.034E-09 9.173E-09 Zn-65 p

3.930E-Ol 1.096E-16 2.741E-08 1.246E-08 Nuclide Type Total 1.487E+OO 4.147E-16 1.964E-07 4.714E*08 N.ll.ciid.e.

Tu Aci:i:v:ity (uCD AY.9 C2as;; (uCils;;t) 8:v:g CQas:.llQxECL 8:v:g Rel Rate (uCi l:zei;;)

I-133 R

3.092E+Ol 8.625E-15 8.625E-07 9.806E-D7 I-131 R

6.415E+OO 1.789E-15 8.947E-07 2.034E-07 Nuclide Type Total 3,734E+01 1.041E-14 1,757E*06 1.184E*06 Total 4.886E+07 1.363E*08 2.075E-01 1.549E+00 User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Period:

Ann, 2021 Site/Unit/Discharge Point:

Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor NW Site Boundary - In WNW Site Boundary - I Maximum Doserate by Organ:

Agegroup Infant Infant Maximum Organ Doserate (mRem/yr):

Maximum Total Body Doserate (mRem/yr):

Site Boundary NG Doserate Summary Gas Receptor Location NW Site Boundary WNW Site Boundary Maximum NG Dose Rate:

User: admin Bone Liver --

5.251E-03 4.712E-03 6.887E-08 6.887E-08 5.251E-03 4.712E-03 5.251E-03 4.712E-03 Gamma (mRad/yr) 2.153E-03 1.855E-03 2.153E-03 Friday, February 11, 2022 13:22 Page 14 of 15 Site Total Body Thyroid Kidney Lung GI-Lli Skin 4.712E-03 4.722E-03 7.337E-04 4.712E-03 4.712E-03 0.000E+00 6.887E-08 6.887E-08 6.887E-08 6.887E-08 6.887E-08 0.000E+DD 4.712E-03 4.722E-03 7.337E-04 4.712E-03 4.712E-03 0.000E+00 Beta (mRad/yr)

Total Body (mRem/yr)

Skin (mRem/yr) 1.394E-03 2.011E-03 3.249E-03 1.201E-03 1.733E-03 2.799E-03 1.394E-03 2.011E-03 3.249E-03

[Server]: PSLSA137 [Database}: NEPSOEMF

Gas Status Summary Report Friday, February 11, 2022 13:22 Page 15 of15 Period:

Ann, 2021 Site/Unit/Discharge Point:

Site Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor Agegroup Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin NW - Near Milk - Adult Adult 3.382E-08 4.824E-08 2.737E-08 1.418E-05 8.073E-08 2.795E*09 l.734E-08 O.OOOE+OO NW Near Milk - Child Child 1.290E-07 l.343E-07 9.711E-08 4.161E-05 8.262E-08 2.778E-09 1.781E-08 O.OOOE+OO NW Near Milk - Infant Infant 2.621E-07 3.172E-07 1.791E-07 9.883E*05 7.649E-08 2.768E-09 l.835E-08 O.OOOE+OO NW Near Milk - Teenager Teenager 5.604E-08 7.946E-08 4.599E-08 2.126E-05 1.018E-07 2.795E-09 2.ll?E-08 O.OOOE+OO SE Nearest Res - Adult Adult 2.412E*08 2.899E-08 2.119E-08 3.106E-06 3.842E-08 l.630E-08 2.199E-08 O.OOOE+OO SE Nearest Res - Child Child 3.123E-08 3.346E-08 2.491E-08 4.733E-06 2.644E*08 l.623E-08 1.971E*08 O.OOOE+OO SE Nearest Res - Infant Infant 2.818E-08 3.235E-08 2.250E-08 4.366E-06 2.00SE-08 1.619E-08 1.762E-08 O.OOOE+OO SE Nearest Res - Teenager Teenager 2.724E-08 3.363E-08 2.314E-08 3.861E-06 3.842E-08 l.630E*08 2.269E-08 O.OOOE+DD SE Visitor - Lifeguard 1.0 mi Adult l.098E-08 l.311E-08 9.703E-09 l.356E-06 l.722E-08 7.568E-09 l.005E-08 O.OODE+OO W Near Garden - Adult Adult 1.087E-08 l.288E-08 9.6581:--09 l.283E-06 l.677E-08 7.639E-09 9.986E-09 O.OOOE+OO W Near Garden - Child Child l.380E-08 l.472E-08 l.119E-08 l.955E-06 l.183E-08 7.608E-09 9.045E-09 O.OOOE+OO W Near Garden - Teenager Teenager l.215E-08 l.479E-08 1.046E-08, 1.595E-06 l.677E-08 7.639E-09 l.028E-08 O.OOOE+OO Maximum Dose by Organ:

2.621E-07 3.172E*07 1.791E-07 9.883E-05 l.018E-07 l.630E-08 2.269E-08 O.OOOE+OO Maximum Organ Dose (mRem):

9.883E-05 Maximum Total Body Dose (mRem):

1.791E-07 Maximum Individual NG Dose Summary Gas Receptor Location Gamma (mRad)

Beta (mRad)

Total Body (mRem)

Skin (mRem)

NW Near Milk 4.25 mi 1.884E-04 1.220E-04 1.760E-04 2.843E-04 SE Nearest Res 1.52 mi 142 deg 9.582E-04 6.204E-04 8.953E-04 1.446E-03 SE Visitor @ 1 mi 4.149E-04 2.686E-04 3.876E-04 6.261E-04 W Near Gard 2.0 miles 3.297E-04 2.134E-04 3.0S0E-04 4.975E-04 Maximum NG Dose:

9.582E-04 6.204E-04 8.953E-04 1.446E-03 User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Friday, February 11, 2022 13:21 Page 8 of 10 Period:

Ann, 2021 Site/Unit/Discharge Point:

PSLl

.liJJ.diM m.e.

Agi:1£i!:)l (uCi)

A:llg C2at (l.lCi ltcJ.

A:llg C2atll!JxcCL A:llg Eel Rate (YCi l:zet)

Xe-133 N

l.881E+05 1.127E-10 2.255E-05 5.9631:-03 Kr-87 N

l.231E+02 7.3831:-14 3.691E-07 3.905E-06 Xe-135 N

1.741E+05 1.0441:-10 1.491E-04 S.522E-03 Ar-41 N

1.009E+06 6.052E-10 6.0521:-03 3.201E-02 Xe-135m N

2.577E+02 1.545E-13 3.862E-07 8.170E-06 Xe-133m N

1.154E+03 6.921E-13 1.1531:-07 3.661E-05 Xe-127 N

4.255E+Ol 2.551E-14 O.OOOE+OO 1.3491:-06 Kr-88 N

2.535E+02 1.520E-13 1.6891:-06 8.0391:-06 Xe-138 N

3.949E+02 2.3671:-13 1.1841:-06 1.2521:-05 Kr-89 N

1.825E+04 1.094E-11 1.0941:-03 5.7871:-04 Nuclide Type Total 1,392E+06 8.346E-10 7.322E-03 4.414E-02

.liJJ.diM m.e.

Agi:lli!:)l (1.1Ci)

A:\lg C2at (YCi £r,.c).

Avg C2atll!JxcCL Avg Eel Rate (uCi l:zec).

C-14 0

l.019E+07 6.1061:-09 2.035E-Ol 3.230E-Ol H-3 0

8.792E+06 5.271E-09 5.271E-03 2.788E-01 G-Alpha 0

3.6711:-02 2.201E-17 2.201E-03 l.164E-09 Nuclide Type Total 1.898E+07 1.138E-08 2.110E-01 6,018E-01

.liJJ.diM m.e.

Agi:lli!:)l (uCi)

Avg C2at (uCi ltcJ.

A:llg C2atll!JxcCL A:llg Eel Rate (uCi l:zec).

Nb-95 p

1.lSSE-01 6.942E-17 3.471E-09 3.6721:-09 Nuclide Type Total 1,158E-01 6.942E-17 3.471E-09 3.672E-09

.liJJ.diM m.e.

Agi:lli!:)l (uCil A:llg C2at (uCi ltcJ A:llg C2atll!JxcCL Avg Eel Rate (uCi l:zec).

I-133 R

3.078E+Ol 1.845E-14 1.845E-06 9.760E-07 I-131 R

3.SSOE+OO 2.128E-15 1.064E-06 l.126E-07 Nuclide Type Total 3.433E+01 2.0SSE-14 2.909E-06 1,089E-06 Total 2,037E+07 1.221E-08 2.183E-01 6,459E-Ol User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Period:

Ann, 2021 Site/Unit/ Discharge Point:

Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor NW Site Boundary - In WNW Site Boundary - I Maximum Doserate by Organ:

Agegroup Infant Infant Maximum Organ Doserate (mRem/yr):

Maximum Total Body Doserate (mRem/yr):

Site Boundary NG Doserate Summary Gas Receptor Location NW Site Boundary WNW Site Boundary Maximum NG Dose Rate:

User: admin Bone Liver 2.609E-03 2.407E-03 5.104E-08 5.104E-08 2.609E-03 2.407E-03 2.609E-03 2.407E-03 Gamma (mRad/yr) 5.131E-04 4.420E-04 5.131E-04 Friday, February 11, 202213:21 Page 9 of 10 PSLl Total Body Thyroid Kidney Lung GI-Lli Skin 2.407E-03 2.415E-03 3.935E-04 2.407E-03 2.407E-03 0.000E+00 5.104E-08 5.104E-08 5.104E-08 5.104E-08 5.104E-08 0.000E+00 2.407E-03 2.415E-03 3.935E-04 2.407E-03 2.407E-03 0.000E+00 Beta (mRad/yr)

Total Body (mRem/yr)

Skin (mRem/yr) 2.099E-04 1.808E-04 2.099E-04 4.874E-04 4.198E-04 4.874E-04 7.312E-04 6.299E-04 7.312E-04

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Friday, February 11, 2022 13:21 Page 10 of 10 Period:

Ann, 2021 Site/Unit/Discharge Point:

PSll Maximum Individual NNG Dose Summary

  • Note: All Doses in mRem Receptor Agegroup
  • sone Liver Total Body Thyroid Kidney Lung GI*Lli Skin NW - Near Milk - Adult Adult 2.112E-08 3.032E-08 1.682E-08 8.554E-06 5.058E-08 2.048E-09 1.206E-08 O.OODE+OO NW Near Milk - Child Child 7.883E-08 8.286E-08 5.823E-08 2.516E-05 5.lOOE-08 2.048E-09 l.27DE-08 O.OOOE+OO NW Near Milk - Infant Infant 1.587E-07 l.940E-07 l.066E-07 5.941E-05 4.706&08 2.048E-09 l.298E-08 O.ODOE+DO NW Near Milk - Teenager Teenager 3.471E-08 4.960&08 2.792E-08 l.284E-05 6.335E-08 2.048E-09 1.490E-08 O.OOOE+OO SE Nearest Res - Adult Adult 1.868E-08 2.302E-08 l.599E-08 2.507E-06 3.117E-08 1.l98E-08 1.746&08 O.OOOE+OO SE Nearest Res - Child Child 2.477E-08 2.697E-08 l.898E-08 3.960E-06 2.084E-08 l.198E-08 l.538E-08 O.OOOE+OO SE Nearest Res - Infant Infant 2.218E-08 2.603E-08 1.707E-08 3.658E-06 1.534E-08 l.198E-08 1.338E-08 O.OOOE+OO SE Nearest Res - Teenager Teenager 2.137E-08 2.709E-08 1.755E-08 3.163E-06 3.117E-08 1.198&08 l.818E-08 O.OOOE+OO SE V1Sitor - Lifeguard 1.0 mi Adult 8.488E-09 l.038E-08 7.313&09 1.095E-06 1.394E-08 5.565E-09 7.956E-09 O.OOOE+OO w Near Garden - Adult Adult 8.385E-09 l.OlSE-08 7.273E-09 1.036E-06 l.354E-08 5.62DE-09 7.882E-09 O.OOOE+OO W Near Garden - Child Child 1.090E-08 1.181E-08 8.510E-09 1.636E-06 9.278E-09 5.620E-09 7.022E-09 O.OOOE+OO W Near Garden - Teenager Teenager 9.496E-09 1.186E-08 7.917E-09 1.307E-06 l.354E-08 5.620E-09 8.179E-09 O.OOOE+OO Maximum Dose by Organ:

l.587E-07 l.940E-07 1.066E-07 5.941E-05 6.335E-08 l.198E-08 1.818&08 O.OOOE+OO Maximum Organ Dose (mRem):

5.941E-05 Maximum Total Body Dose (mRem):

1.066E-07 Maximum Individual NG Dose Summary Gas Receptor Location Gamma (mRad)

Beta (mRad)

Total Body (mRem)

Skin (mRem)

NW Near Milk 4.25 mi 4.490E-05 1.836E-05 4.265E-05 6.398E-05 SE Nearest Res 1.52 mi 142 deg 2.284E-04 9.340E-05 2.169E-04 3.254E-04 SE Visitor @ 1 mi 9.889E-05 4.0:'14E-0S 9.393E-05 1.409E-04 W Near Gard 2.0 miles 7.858E-05 3.213E-05 7.463E-05 1.120E-04 Maximum NG Dose:

2.284E-04 9.340E-05 2.169E-04 3.254E-04 User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Friday, February 11, 2022 13:18 Page 7 of 9 Period:

Ann, 2021 Site/Unit/Discharge Point:

PSL2 NYcilll.e.

ms:.

Ad:iYitl!'. (uCD AYg C2at (1.1Ci £tr;).

Avg C2atl10xl;CL AYg Bel Bate (1.1Ci £~et)

Xe-13lm N

1.065E+07 5.556E-09 2.778E-04 3.378E-01 Kr-85m N

3.829E+04 1.997E-ll 1.997E-05 1.214E-03 Xe-138 N

3.657E+Ol 1.907E-14 9.535E-08 l.159E-06 Xe-133m N

2.074E+02 1.082E-13 1.803E-08 6.576E-06 Xe-135m N

5.468E+05 2.852E-10 7.129E-04 1.734E-02 Xe-127 N

2.225E+Ol 1.161E-14 O.OOOE+OO 7.057E-07 Xe-135 N

4.359E+04 2.274E-11 3.248E-05 1.382E-03 Xe-133 N

8.816E+05 4.59BE-10 9.196E-05 2.796E-02 Ar-41 N

3.052E+06 1.592E-09 1.592E-02 9.677E-02 Nudide Type Total 1,521E+07 7.935E-09 1.70SE-02 4,82SE-Ol NYcilll.e.

~

Ad:ilt:itl!'. (1.1CD A:11:g C2nt (1.1Ci lttl A:11:g C2ntl10Xl;CL A:11:g Bel Bate (!.!Ci £~er;).

C-14 0

1.032E+07 5.381E-09 1.794E-01 3.271E-01 H-3 0

2.960E+06 1.544E-09 1.544E-03 9.386E-02 G-Alpha 0

2.184E-03 1.139E-18 l.139E-04 6.924E-11 Nudide Type Total 1.328E+07 6,924E-09 1.SlOE-01 4.210E-01 NYcilll.e.

ms:.

Ad:i:llitl!'. (1.1Cil A:llg C2at (1.1Ci £tr;).

Avg C2otl10xECL AY9 Bel Bate (uCi £~er;).

Cr-51 p

S.095E-01 2.657E-16 8.857E-10 1.616E-08 Co-60 p

2.949E-01 1.538E-16 3.076E-07 9.350E-09 Nb-95 p

1.735E-01 9.049E-17 4.524E-09 5.502E-09 Zn-65 p

3.930E-01 2.0SOE-16 5.125E-08 1.246E-08 Nudide Type Total 1.371E+OO 7.lSOE-16 3.642E-07 4.347E-08 N.l!&.fu!e.

~

Ad:ivitii: (!.!Ci)

Avg C2nt (l!Ci lrsJ.

Avg C2ntl10:i!:EC!.

Avg Rel Bi:!te (!.!Ci l~er;).

I-133 R

1.440E-01 7.513E-17 7.513E-09 4.568E-09 I-131 R

2.866E+OO 1.495E-15 7.473E-07 9.087E-08 Nudide Type Total 3.0lOE+OO 1.570E-15 7.548E-07 9.544E-08 Total 2.849E+07 1.486E-08 1,981E-Ol 9.03SE-Ol User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Period:

Ann, 2021 Site/Unit/Discharge Point:

Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor NW Site Boundary - In WNW Site Boundary - I -

Maximum Doserate by Organ:

Agegroup Infant Infant Maximum Organ Doserate (mRem/yr):

Maximum Total Body Doserate (mRem/yr):

Site Boundary NG Doserate Summary Gas Receptor Location NW Site Boundary WNW Site Boundary Maximum NG Dose Rate:

User: admin Bone Liver 2.642E-03 2.305E-03 1.783E-08 1.783E-08 2.642E-03 2.305E-03 2.642E-03 2.305E-03 Gamma (mRad/yr) l.640E-03 1.413E-03 1.640E-03 Friday, February 11, 2022 13:18 Page 8 of 9 PSL2 Total Body Thyroid Kidney Lung GI*Lli Skin 2.305E-03 2.306E-03 3.402E-04 2.305E-03 2.305E-03 0.000E+00 1.783E-08 1.783E-08 1.783E-08 1.783E-08 1.783E-08 0.000E+00 2.305E-03 2.306E-03 3.402E-04 2.305E-03 2.305E-03 0.000E+00 Beta (mRad/yr)

Total Body (mRem/yr)

Skin (mRem/yr) 1.184E-03 1.524E-03 2.518E-03 1.020E-03 1.313E-03 2.169E-03 1.184E-03 1.524E-03 2.518E-03

[Server]: PSLSA137 [Database]: NEPSOEMF

Gas Status Summary Report Friday, February 11, 2022 13:18 Page 9 of9 Period:

Ann, 2021 Site/Unit/Discharge Point:

PSL2 Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor Agegroup Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin NW - Near Milk - Adult Adult 1.270E-08 1.792E-08 1.055E-08 5.630E-06 3.015E-08 7.4nE-10 5.274E-09 O.OOOE+OO NW Near Milk - Child Child 5.022E-08 5.141E-08 3.888E-08 1.645E-05 3.162E-08 7.302E-10 5.112E-09 O.OOOE+OO NW Near Milk - Infant Infant l.034E-07 1.232E-07 7.249E-08 3.942E-05 2.943E-08 7.208E-10 5.368E-09 O.OOOE+OO NW Near Milk - Teenager Teenager 2.133E-08 2.986E-08 1.807E-08 8.418E-06 3.848E-08 7.478E-10 6.273E-09 O.OOOE+OO SE Nearest Res - Adult Adult 5.441E-09 5.970E-09 5.207E-09 5.984E-07 7.249E-09 4.321E-09 4.528E-09 O.OOOE+OO SE Nearest Res - Child Child 6.455E-09 6.495E-09 5.931E-09 7.731E-07 5.601E-09 4.247E-09 4.330E-09 O.OOOE+OO SE Nearest Res - Infant Infant 5.995E-09 6.315E-09 5.436E-09 7.082E-07 4.717E-09 4.207E-09 4.242E-09 O.OOOE+OO SE Nearest Res - Teenager Teenager 5.866E-09 6.540E-09 5.592E-09 6.982E-07 7.249E-09 4.321E-09 4.512E-09 O.OOOE+OO SE Visitor - Lifeguard 1.0 mi Adult 2.492E-09 2.723E-09 2.390E-09 2.613E-07 3.281E-09 2.003E-09 2.093E-09 O.OOOE+OO W Near Garden - Adult Adult 2.481E-09 2.700E-09 2.385E-09 2.473E-07 3.228E-09 2.019E-09 2.104E-09 O.OOOE+OO W Near Garden - Child Child 2.900E-09 2.916E-09 2.684E-09 3.195E-07 2.547E-09 1.988E-D9 2.023E-Q9 O.OOOE+OO W Near Garden - Teenager Teenager 2.657E-09 2.935E-09 2.544E-09 2.885E-07 3.228E-09 2.019E-09 2.098E-09 O.OOOE+OO Maximum Dose by Organ:

1.034E-07 l.232E-Q7 7.249E-08 3.942E-05 3.848E-08 4.321E-09 6.273E-09 O.OOOE+OO Maximum Organ Dose (mRem):

3.942E-05 Maximum Total Body Dose (mRem):

7.249E-08 Maximum Individual NG Dose Summary Gas Receptor Location Gamma (mRad)

Beta (mRad)

Total Body (mRem)

Skin (mRem)

NW Near Milk 4.25 mi 1.435E-04 1.036E-04 1.334E-04 2.203E-04 SE Nearest Res L52 mi 142 deg 7.298E-04 5.270E-04 6.783E-04 1.121E-03 SE Visitor @ 1 mi 3.160E-04 2.282E-04 2.937E-04 4.852E-04 W Near Gard 2.0 miles 2.511E-04 1.813E-04 2.334E-04 3.855E-04 Maximum NG Dose:

7.298E-04 5.270E-04 6.783E-04 1.121E-03 User: admin

[Server]: PSLSA137 [Database]: NEPSOEMF

TABLE 3.4 VISITOR DOSE (1 PAGE)

L-2022-023 Enclosure

3.4 Visitor Dose L-2022-023 Enclosure Dose to a Member of the Public from Activities Inside the Site Boundary Assessment of radiation dose from radioactive effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY assumes the VISITOR to be a Lifeguard at the Walton Rocks Beach recreation area.

The visitor is assumed to be onsite for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> per day for 312 days per year at a distance of 1 mile in the South East sector. The VISITOR received exposure from each of the two reactors on Site. Actual Met Data was used to calculate Visitor Dose for Calendar Year 2021, and the results are below.

Noble Gas Dose Gamma Air Dose Beta Air Dose Gas, Particulate, Iodine, Carbon Dose Bone Liver Thvroid Kidney Lung GI-LLI Total Body mrad 9.79E-04 6.34E-04 mrem 5.37E-09 6.4 lE-09 6.64E-07 8.42E-09 3.70E-09 4.92E-09 4.75E-09