Cecil Fletcher General Manager (Acting)

Nuclear Regulatory Affairs, Policy &

Emergency Preparedness Duke Energy CN03CH l 4800 Concord Rd York, SC 29745 704.382.4534 Cecil.Fletcher@duke-energy.com RA-23-0104 April 26, 2023 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Oconee Nuclear Station, Unit 3 Docket No. 50-287 Renewed License No. DPR-55

Subject:

Response to Request for Additional Information (RAI) Regarding Oconee Unit 3, Refuel 31 (O3R31) Steam Generator Tube Inspection Report

References:

1. Duke Energy letter, Oconee Unit 3, Refuel 31 (O3R31) Steam Generator Tube Inspection Report, dated November 21, 2022 (ADAMS Accession No. ML22325A362).
2. NRC e-mail, Oconee Unit 3 - Request for Additional Information RE: Steam Generator Tube Inspection Report (O3R31) (EPID: L-2022-LRO-0152), dated March 27, 2023 (ADAMS Accession No. ML23086C036).

By letter dated November 21, 2022 (Reference 1), Duke Energy Carolinas, LLC (Duke Energy) submitted the steam generator tube inspection report to the U.S. Nuclear Regulatory Commission (NRC) for Oconee Unit 3, refueling outage 31 (O3R31) in accordance with plant Technical Specifications (TS). Specifically, TS 5.6.8 requires that a report be submitted within 180 days after the initial entry into hot shutdown (i.e., MODE 4) following completion of a steam generator tube inspection performed in accordance with TS 5.5.10. TS 5.5.10 requires that a SG Program be established and implemented to ensure SG tube integrity is maintained.

By electronic mail correspondence dated March 27, 2023 (Reference 2), the NRC staff requested additional information from Duke Energy to complete its review of the O3R31 steam generator tube inspection report.

The enclosure to this letter provides Duke Energys response to the NRC RAI regarding the O3R31 steam generator tube inspection report.

There are no regulatory commitments contained in this submittal.

( ~ DUKE ENERGY

U.S. Nuclear Regulatory Commission RA-23-0104 Page 2 Please refer any questions regarding this submittal to Ryan Treadway, Director - Nuclear Fleet Licensing, at 980-373-5873.

Sincerely, Cecil Fletcher General Manager (Acting) - Nuclear Regulatory Affairs, Policy & Emergency Preparedness

Enclosure:

Response to NRC Request for Additional Information

U.S. Nuclear Regulatory Commission Page 3 RA-23-0104 cc: (w/ Enclosure)

Ms. Laura Dudes Administrator, Region II U.S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Avenue NE, Suite 1200 Atlanta, GA 30303-1257 Mr. Shawn Williams NRC Project Manager Oconee Nuclear Station Mr. Jared Nadel NRC Senior Resident Inspector Oconee Nuclear Station

U.S. Nuclear Regulatory Commission Enclosure to RA-23-0104 Enclosure Response to NRC Request for Additional Information

[7 pages follow this cover page]

U.S. Nuclear Regulatory Commission Enclosure to RA-23-0104 By letter dated November 21, 2022 (Agencywide Documents Access and Management Systems Accession No. ML22325A362), Duke Energy submitted information summarizing the results of the spring 2022 steam generator (SG) inspections performed at Oconee Nuclear Station, Unit 3.

The inspections were performed during refueling outage (RFO) 31. Technical Specification (TS)

Section 5.5.10 requires that a SG Program be established and implemented to ensure SG tube integrity is maintained. TS Section 5.6.8 requires that a report be submitted within 180 days after the initial entry into hot shutdown (MODE 4) following completion of an inspection of the SGs.

Some information about the classification, tracking, and reporting of tube-to-tube wear indications for the Oconee Unit 3 steam generators is unclear to the U.S. Nuclear Regulatory Commission (NRC) staff. Specifically, The Unit 3 reports from the most recent inspections, 2022 (RFO 31, ML22325A362) and 2018 (RFO 29, ML18235A502), appear to use the code VTW for tube-to-tube wear in the listing of indications. The 2018 report also includes indications classified as HNC, but the 2022 report does not have any indications classified as HNC.

The 2018 and 2022 reports for Unit 3 do not define the abbreviations VTW or HNC, but the staff understands HNC to be an abbreviation for Historical No Change based on Unit 3 and Unit 2 steam generator tube inspection reports.

All tube-to-tube wear indications in the 2021 inspection report for Unit 2 appear to be classified as TTW (Tube-to-Tube Wear), ADI (Absolute Drift Indication), or VTW. The text in the 2021 Unit 2 report describes the meaning of TTW and ADI, but not VTW.

Therefore, to complete its review of the inspection report, the NRC staff requests the following additional information:

1. Please clarify whether the HNC code is used as a basis for omitting tube-to-tube wear indications from SG tube inspection reports. The 2018 report for Oconee Unit 3 appears to include tube-to-tube wear indications classified as HNC that were not included in the 2022 report (e.g., SG 3A, tubes R91C51 and R92C51). If indications are excluded based on classification as HNC, please discuss the apparent discepancy with Technical Specification 5.6.8.d, which requires the reporting of the Location, orientation (if linear),

and measured sizes (if available) of service induced indications.

Duke Energy Response to RAI 1 The NRC staff correctly understands the HNC to be an abbreviation for Historical No Change.

The HNC code was used as a basis for omitting historic tube-to-tube wear from the indication list of the SG tube inspection reports. The HNC code tube-to-tube wear indications were discussed in the body of the 2022 Unit 3 SG tube inspection report. The HNC code is used for tracking historical indications that have not changed from their historical (HNC) conditions during the current inspection. Prior to HNC classification, the tube-to-tube wear indications have been reported in the indication list of previous SG tube inspection reports. Duke Energy understands the need for the HNC code associated with service induced indications to be included in the indication list of the SG tube inspection reports. Therefore, attached are the service induced HNC codes that were not included in the O3R31 steam generator tube inspection report.

U.S. Nuclear Regulatory Commission Enclosure to RA-23-0104

2. Please define eddy current three-letter Code VTW and discuss the difference between Codes VTW and TTW assigned to tube-to-tube wear indications within the Oconee units.

Duke Energy Response to RAI 2 The VTW (Volumetric Tube Wear) code is an Array reporting code for tube-to-tube wear. The TTW (Tube-to-Tube Wear) code is a Bobbin reporting code used on subsequent inspections after the diagnostic probe has determined the indication is tube-to-tube wear.

SG - 3A Attachment - Service Induced Indications Oconee 3 O3R31 BOCO3 20220501 04/17/2023 12:42:05

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l 2022/05/01 91 51 1.79 94 HNC P8 007 15.55 24.57 CTR 9.02 UTE LTE.510 ZBAHS 50 C 242l l l l 2022/05/01 92 51 1.60 97 HNC P8 007 15.48 23.97 CTR 8.49 UTE LTE.510 ZBAHS 51 C 220l l l l 2022/05/01 91 52 2.20 95 HNC P8 007 15.05 26.30 CTR 11.25 UTE LTE.510 ZBAHS 50 C 226l l l l 2022/05/01 92 54.52 106 HNC P8 007 15.66 23.17 CTR 7.51 UTE LTE.510 ZBAHS 51 C 203l l l l 2022/05/01 93 54 1.09 105 HNC P8 007 15.23 24.09 CTR 8.86 UTE LTE.510 ZBAHS 51 C 202l l l l 2022/05/01 78 55.89 120 HNC P8 007 16.89 25.52 CTR 8.63 UTE LTE.510 ZBAHS 51 C 281l l l l 2022/05/01 92 55 1.84 96 HNC P8 007 15.28 23.80 CTR 8.52 UTE LTE.510 ZBAHS 51 C 204l l l l 2022/05/01 93 55.87 104 HNC P8 007 12.90 23.91 CTR 11.01 UTE LTE.510 ZBAHS 50 C 209l l l l 2022/05/01 78 56 1.45 97 HNC P8 007 16.44 24.54 CTR 8.10 UTE LTE.510 ZBAHS 51 C 282l l l l 2022/05/01 79 56.84 93 HNC P8 007 17.38 23.89 CTR 6.51 UTE LTE.510 ZBAHS 51 C 279l l l l 2022/05/01 92 56.88 112 HNC P8 007 16.50 23.10 CTR 6.60 UTE LTE.510 ZBAHS 50 C 211l l l l 2022/05/01 79 57 1.57 100 HNC P8 007 15.43 25.82 CTR 10.39 UTE LTE.510 ZBAHS 50 C 292l l l l 2022/05/01 80 57 1.01 95 HNC P8 007 15.82 24.62 CTR 8.80 UTE LTE.510 ZBAHS 50 C 290l l l l 2022/05/01 87 57.67 105 HNC P8 007 13.94 26.08 CTR 12.14 UTE LTE.510 ZBAHS 51 C 247l l l l 2022/05/01 88 57.59 102 HNC P8 007 15.47 22.98 CTR 7.51 UTE LTE.510 ZBAHS 50 C 267l l l l 2022/05/01 95 57.66 128 HNC P8 007 14.44 21.63 CTR 7.19 UTE LTE.510 ZBAHS 51 C 187l l l l 2022/05/01 79 58.83 96 HNC P8 007 17.00 24.83 CTR 7.83 UTE LTE.510 ZBAHS 50 C 307l l l l 2022/05/01 81 58.82 104 HNC P8 007 17.58 23.76 CTR 6.18 UTE LTE.510 ZBAHS 50 C 289l l l l 2022/05/01 89 58.55 119 HNC P8 007 15.47 23.10 CTR 7.63 UTE LTE.510 ZBAHS 50 C 281l l l l 2022/05/01 92 58.96 105 HNC P8 007 14.67 23.71 CTR 9.04 UTE LTE.510 ZBAHS 51 C 193l l l l 2022/05/01 86 59.80 107 HNC P8 007 15.09 23.65 CTR 8.71 UTE LTE.510 ZBAHS 51 C 250l l l l 2022/05/01 86 60.77 102 HNC P8 007 16.33 23.46 CTR 7.13 UTE LTE.510 ZBAHS 50 C 283l l l l 2022/05/01 87 66.53 92 HNC P8 007 16.71 22.69 CTR 5.98 UTE LTE.510 ZBAHS 58 C 45l l l l 2022/05/01 72 67.64 94 HNC P8 007 13.63 25.17 CTR 11.54 UTE LTE.510 ZBAHS 53 C 253l l l l 2022/05/01 73 67.70 87 HNC P8 007 14.25 24.52 CTR 7.44 UTE LTE.510 ZBAHS 53 C 249l l l l 2022/05/01 74 67.58 78 HNC P8 007 13.97 23.35 CTR 9.38 UTE LTE.510 ZBAHS 53 C 246l l l l 2022/05/01 73 68.96 86 HNC P8 007 14.14 25.08 CTR 10.94 UTE LTE.510 ZBAHS 53 C 250l l l

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

1 ST Max

SG - 3A Attachment - Service Induced Indications Oconee 3 O3R31 BOCO3 20220501 04/17/2023 12:42:05

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l 2022/05/01 60 69 1.49 94 HNC P8 007 13.89 24.88 CTR 10.99 UTE LTE.510 ZBAHS 53 C 202l l l l 2022/05/01 60 70 1.21 85 HNC P8 007 15.73 23.35 CTR 7.62 UTE LTE.510 ZBAHS 53 C 203l l l l 2022/05/01 72 70.73 85 HNC P8 007 16.01 22.70 CTR 6.69 UTE LTE.510 ZBAHS 53 C 269l l l l 2022/05/01 71 71.80 85 HNC P8 007 15.86 24.88 CTR 9.02 UTE LTE.510 ZBAHS 53 C 271l l l l 2022/05/01 79 71.83 92 HNC P8 007 13.00 26.15 CTR 13.75 UTE LTE.510 ZBAHS 59 C 15l l l l 2022/05/01 83 71.57 86 HNC P8 007 11.85 23.82 CTR 13.16 UTE LTE.510 ZBAHS 58 C 59l l l l 2022/05/01 71 72.81 95 HNC P8 007 13.71 26.75 CTR 13.04 UTE LTE.510 ZBAHS 53 C 272l l l l 2022/05/01 79 72.74 85 HNC P8 007 12.96 24.15 CTR 9.29 UTE LTE.510 ZBAHS 59 C 16l l l l 2022/05/01 60 73.56 117 HNC P8 007 16.91 23.09 CTR 6.18 UTE LTE.510 ZBAHS 31 C 202l l l l 2022/05/01 72 73.70 94 HNC P8 007 16.67 25.26 CTR 8.59 UTE LTE.510 ZBAHS 27 C 275l l l l 2022/05/01 80 73.50 82 HNC P8 007 15.40 23.19 CTR 7.79 UTE LTE.510 ZBAHS 27 C 246l l l l 2022/05/01 84 73.68 108 HNC P8 007 16.02 22.95 CTR 6.93 UTE LTE.510 ZBAHS 28 C 185l l l l 2022/05/01 85 73.56 104 HNC P8 007 16.01 22.74 CTR 6.73 UTE LTE.510 ZBAHS 27 C 230l l l l 2022/05/01 60 74.43 99 HNC P8 007 17.54 22.77 CTR 5.23 UTE LTE.510 ZBAHS 31 C 201l l l l 2022/05/01 72 74.84 103 HNC P8 007 14.55 26.82 CTR 12.27 UTE LTE.510 ZBAHS 28 C 228l l l l 2022/05/01 79 74.89 92 HNC P8 007 12.95 24.69 CTR 11.74 UTE LTE.510 ZBAHS 27 C 250l l l l 2022/05/01 80 74.70 86 HNC P8 007 13.68 22.52 CTR 8.84 UTE LTE.510 ZBAHS 28 C 202l l l l 2022/05/01 94 74.72 117 HNC P8 007 13.47 25.87 CTR 12.40 UTE LTE.510 ZBAHS 27 C 197l l l l 2022/05/01 95 74.68 110 HNC P8 007 15.22 23.58 CTR 8.36 UTE LTE.510 ZBAHS 27 C 194l l l l 2022/05/01 70 75 1.25 89 HNC P8 007 13.79 26.58 CTR 12.79 UTE LTE.510 ZBAHS 28 C 232l l l l 2022/05/01 71 76 1.32 96 HNC P8 007 14.49 26.37 CTR 11.88 UTE LTE.510 ZBAHS 28 C 224l l l l 2022/05/01 86 76.61 117 HNC P8 007 14.52 23.78 CTR 9.26 UTE LTE.510 ZBAHS 28 C 187l l l l 2022/05/01 87 76.50 122 HNC P8 007 15.27 24.21 CTR 8.94 UTE LTE.510 ZBAHS 27 C 224l l l l 2022/05/01 82 78.69 123 HNC P8 007 15.58 24.11 CTR 8.53 UTE LTE.510 ZBAHS 31 C 134l l l l 2022/05/01 85 78.64 115 HNC P8 007 11.72 25.63 CTR 13.91 UTE LTE.510 ZBAHS 28 C 191l l l l 2022/05/01 92 78 1.71 96 HNC P8 007 14.41 26.33 CTR 11.92 UTE LTE.510 ZBAHS 28 C 169l l l l 2022/05/01 68 79 1.32 113 HNC P8 007 15.54 23.60 CTR 8.06 UTE LTE.510 ZBAHS 28 C 240l l l

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

2 ST Max

SG - 3A Attachment - Service Induced Indications Oconee 3 O3R31 BOCO3 20220501 04/17/2023 12:42:05

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l 2022/05/01 69 79.55 100 HNC P8 007 16.10 24.25 CTR 8.15 UTE LTE.510 ZBAHS 31 C 175l l l l 2022/05/01 83 79.73 115 HNC P8 007 13.70 25.65 CTR 11.95 UTE LTE.510 ZBAHS 31 C 131l l l l 2022/05/01 88 79.73 110 HNC P8 007 13.76 25.72 CTR 11.96 UTE LTE.510 ZBAHS 28 C 181l l l l 2022/05/01 91 79 1.85 92 HNC P8 007 13.55 26.02 CTR 12.47 UTE LTE.510 ZBAHS 32 C 104l l l l 2022/05/01 92 79.69 105 HNC P8 007 16.33 23.43 CTR 7.10 UTE LTE.510 ZBAHS 31 C 104l l l l 2022/05/01 69 80 1.13 100 HNC P8 007 12.79 25.16 CTR 12.37 UTE LTE.510 ZBAHS 32 C 167l l l l 2022/05/01 70 80.56 104 HNC P8 007 16.19 22.81 CTR 6.62 UTE LTE.510 ZBAHS 32 C 165l l l l 2022/05/01 75 89.72 100 HNC P8 007 13.91 23.21 CTR 9.30 UTE LTE.510 ZBAHS 41 C 61l l l l 2022/05/01 76 89.71 101 HNC P8 007 14.49 23.58 CTR 9.09 UTE LTE.510 ZBAHS 45 C 9l

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

Tubes: 63 Records: 63 3 ST Max

SG - 3B Attachment - Service Induced Indications Oconee 3 O3R31 BOCO3 20220501 04/17/2023 12:46:19

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l 2022/05/01 78 60.56 104 HNC P8 007 17.40 24.10 CTR 6.70 UTE LTE.510 ZBAHS 34 C 240l l l l 2022/05/01 78 64.88 83 HNC P8 007 15.44 24.42 CTR 8.98 UTE LTE.510 ZBAHS 55 C 144l l l l 2022/05/01 76 65 1.24 79 HNC P8 007 14.17 24.10 CTR 9.93 UTE LTE.510 ZBAHS 55 C 152l l l l 2022/05/01 77 66 1.57 76 HNC P8 007 15.11 23.48 CTR 8.37 UTE LTE.510 ZBAHS 54 C 165l l l l 2022/05/01 77 67.62 72 HNC P8 007 15.77 23.41 CTR 7.64 UTE LTE.510 ZBAHS 55 C 135l l l l 2022/05/01 84 67.61 80 HNC P8 007 16.44 24.05 CTR 7.61 UTE LTE.510 ZBAHS 55 C 166l l l l 2022/05/01 57 68 1.09 84 HNC P8 007 15.08 23.40 CTR 8.32 UTE LTE.510 ZBAHS 59 C 149l l l l 2022/05/01 58 69 1.10 87 HNC P8 007 13.49 24.96 CTR 11.47 UTE LTE.510 ZBAHS 58 C 209l l l l 2022/05/01 56 70.65 113 HNC P8 007 16.05 25.26 CTR 9.21 UTE LTE.510 ZBAHS 57 C 122l l l l 2022/05/01 56 71.92 94 HNC P8 007 15.51 23.02 CTR 7.51 UTE LTE.510 ZBAHS 57 C 123l l l l 2022/05/01 60 71.58 84 HNC P8 007 15.36 21.71 CTR 6.35 UTE LTE.510 ZBAHS 57 C 109l l l l 2022/05/01 79 71.76 80 HNC P8 007 14.39 25.49 CTR 11.10 UTE LTE.510 ZBAHS 55 C 124l l l l 2022/05/01 80 71.79 79 HNC P8 007 16.42 23.06 CTR 6.64 UTE LTE.510 ZBAHS 54 C 136l l l l 2022/05/01 60 72.87 100 HNC P8 007 15.76 23.39 CTR 7.63 UTE LTE.510 ZBAHS 57 C 110l l l l 2022/05/01 71 73.56 110 HNC P8 007 15.30 22.65 CTR 7.35 UTE LTE.510 ZBAHS 52 C 188l l l l 2022/05/01 87 73.73 76 HNC P8 007 15.28 22.51 CTR 7.23 UTE LTE.510 ZBAHS 52 C 86l l l l 2022/05/01 60 74.54 81 HNC P8 007 15.67 21.81 CTR 6.14 UTE LTE.510 ZBAHS 56 C 200l l l l 2022/05/01 63 75 1.11 88 HNC P8 007 15.45 27.91 CTR 12.46 UTE LTE.510 ZBAHS 56 C 190l l l l 2022/05/01 70 75.79 86 HNC P8 007 16.03 23.13 CTR 7.10 UTE LTE.510 ZBAHS 53 C 174l l l l 2022/05/01 63 76 1.04 78 HNC P8 007 16.50 24.40 CTR 7.90 UTE LTE.510 ZBAHS 56 C 191l l l l 2022/05/01 66 76.95 93 HNC P8 007 15.47 23.30 CTR 7.83 UTE LTE.510 ZBAHS 52 C 206l l l l 2022/05/01 67 76.77 94 HNC P8 007 15.67 24.39 CTR 8.72 UTE LTE.510 ZBAHS 52 C 203l l l l 2022/05/01 68 76.82 85 HNC P8 007 15.82 24.73 CTR 8.91 UTE LTE.510 ZBAHS 53 C 187l l l l 2022/05/01 70 76.61 85 HNC P8 007 15.68 23.45 CTR 7.77 UTE LTE.510 ZBAHS 52 C 193l l l l 2022/05/01 71 76 1.00 88 HNC P8 007 14.61 22.55 CTR 7.94 UTE LTE.510 ZBAHS 53 C 177l l l l 2022/05/01 68 77.67 102 HNC P8 007 16.03 25.31 CTR 9.28 UTE LTE.510 ZBAHS 52 C 200l l l l 2022/05/01 69 77.89 87 HNC P8 007 15.49 23.51 CTR 8.02 UTE LTE.510 ZBAHS 52 C 197l l l

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

1 ST Max

SG - 3B Attachment - Service Induced Indications Oconee 3 O3R31 BOCO3 20220501 04/17/2023 12:46:19

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l 2022/05/01 71 77 1.02 84 HNC P8 007 13.46 24.39 CTR 10.93 UTE LTE.510 ZBAHS 52 C 190l l l l 2022/05/01 83 77.59 66 HNC P8 007 16.58 21.59 CTR 5.01 UTE LTE.510 ZBAHS 52 C 101l l l l 2022/05/01 48 78.69 111 HNC P8 007 16.73 25.89 CTR 9.16 UTE LTE.510 ZBAHS 56 C 274l l l l 2022/05/01 68 78.52 73 HNC P8 007 15.76 22.81 CTR 7.05 UTE LTE.510 ZBAHS 52 C 218l l l l 2022/05/01 69 78.77 86 HNC P8 007 15.80 23.44 CTR 7.64 UTE LTE.510 ZBAHS 52 C 215l l l l 2022/05/01 49 79.70 114 HNC P8 007 15.49 23.49 CTR 8.00 UTE LTE.510 ZBAHS 56 C 272l l l l 2022/05/01 61 79.68 70 HNC P8 007 15.25 22.98 CTR 7.73 UTE LTE.510 ZBAHS 60 C 21l l l l 2022/05/01 62 79.70 87 HNC P8 007 14.89 22.52 CTR 7.63 UTE LTE.510 ZBAHS 61 C 17l l l l 2022/05/01 69 79.88 91 HNC P8 007 14.22 25.20 CTR 10.98 UTE LTE.510 ZBAHS 53 C 185l l l l 2022/05/01 70 79.89 97 HNC P8 007 14.86 22.79 CTR 7.93 UTE LTE.510 ZBAHS 53 C 182l

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl

+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+

Tubes: 37 Records: 37 2 ST Max