Description of Changes from R2 to R3
ML23097A117
Person / Time
Site: Holtec
Issue date: 04/05/2023
From:
Storage and Transportation Licensing Branch
To:
Holtec
Shared Package
ML23097A114 List:
References
EPID L-2021-LLT-003
Download: ML23097A117 (1)


Text

Description of changes from R2 to R3, by location (page number)

Location Description / Justification Page 1 Some minor editorial changes for clarity Page 2 Some minor editorial changes for clarity Page 3 Some minor editorial changes for consistency Page 4 Made text consistent with the revision to Appendices D, E and F Page 5 Some minor editorial changes for clarity Made text consistent with the revision to Appendices D, E and F Page 6 Removed duplicate text that is already on Page 7; included NFH for clarity Page 7 Some minor editorial changes for clarity Discussion on dose points, consistent with Appendix B, Section B.2 New options for BECT evaluations (RAI 11(i))

Page 8 Continued new options for BECT evaluations (RAI 11(i))

Page 9 Continued new options for BECT evaluations (RAI 11(i))

Clarified that requirements for NFH BECTs are treated the same as for fuel.

Page 10 Some minor editorial changes for clarity Removed discussion on fuel condition which is now moved to in Section 2.8.9 Removed reference to ORAs, since this is already addressed in Table 2.2.

Page 11 Some minor editorial changes for clarity Page 12 Clarified that the power to be compared with the value in Table 2.2 is the average over the irradiation time.

Page 13 Some minor editorial changes for clarity Page 16 Expanded/clarified water density Page 17 Some minor editorial changes for clarity Clarified that the FSAR may define a different design basis fuel Page 18 Some minor editorial changes for clarity

Removed duplicate discussion on Zircaloy impurity Page 19 Some minor editorial changes for clarity Page 20 Added more detailed discussion on calculations for steel rods/

Page 21 Some minor editorial changes for clarity Page 22 Some minor editorial changes for clarity Clarification about NFH masses different from those in Table 3.4 Removed duplication of discussion on AgInCd from Page 19 Page 24 Typographical correction Clarified NFH consideration in source term calculation Page 34 Some minor editorial changes for clarity Added reference to Section 2.6 for clarification.

Pages A-1 through A-3 Clarified that the dose rate limits are part of the inputs Clarified that contents needs to conform to area of applicability Explicitly referenced tables for design basis fuel Referenced section 2.6 for representative content evaluation Page A-6 and A-9 Removed tables no longer needed Page B-1 Removed item 7, which is no longer needed based on discussion in 2.8.9 Page B-2, Section B.4 For the representative content, clarified that uniform or regionalized loading may be more representative.

Page B-3 Added Section B.5 to address the options for evaluating accident conditions with respect to the requirements in 10 CFR 72.106. (will be updated in R4 of the report)

Appendix C Replaced in its entirety, no revision bars Appendix E and F

Clarified that this format is required Added discussions on Co-59 in NFH, CRA insertion, and specific power Updated the example for consistency with revised Section 2.6