Letter Sequence Approval |
|---|
EPID:L-2021-LLT-0003, International, Submittal of Revision 0 of the Topical Report on Methodology for Fuel Qualification (Approved, Closed) |
|
MONTHYEARML21152A2582021-05-31031 May 2021 International, Submittal of Revision 0 of the Topical Report on Methodology for Fuel Qualification Project stage: Request ML21260A0182021-09-16016 September 2021 NRC Form 699_Clarification Call_09-16-2021 Conversation Record Project stage: Approval ML21299A2662021-11-0303 November 2021 Enclosure - Moe Topical Report RAIs Project stage: Other ML21299A2882021-11-0303 November 2021 Shielding Moe Topical Report - RAI Project stage: Request ML21299A2652021-11-0303 November 2021 RAI Letter to Holtec_Shielding Moe Topical Report Project stage: RAI ML23032A4492023-02-0101 February 2023 International - Submittal of Supplemental Information to RAI Responses on the Topical Report on Methodology for Fuel Qualification Project stage: Request ML23097A1172023-04-0505 April 2023 Description of Changes from R2 to R3 Project stage: Other ML23097A1162023-04-0505 April 2023 Enclosusummary of Discussion 04-05-2023 Project stage: Other ML23097A1152023-04-0505 April 2023 NRC Form 699 Clarification Call: 04-05-2023 Project stage: Approval ML23104A3772023-04-13013 April 2023, 14 April 2023 International, Submittal of Revision 4 of the Topical Report on Methodology for Fuel Qualification Project stage: Request ML23135A7562023-07-20020 July 2023 Draft Safety Evaluation for HI-2210161, Revision No. 4, Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Project stage: Request ML23135A7582023-07-20020 July 2023 Letter to Holtec - Draft SE for HI-2210161, Revision No. 4, Topical Report Project stage: Draft Approval ML23135A7592023-07-20020 July 2023 Shielding Topical Draft SE Project stage: Draft Approval ML23234A1572023-09-14014 September 2023 Letter to Holtec International Final Safety Evaluation for Hi-2210161, Revision No. 4, Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Project stage: Approval ML23234A1582023-09-14014 September 2023 Final Safety Evaluation for Hi-2210161, Revision No. 4, Topical Report on the Radiological Fuel Qualification Methodology for Dry Storage Systems Project stage: Approval ML23234A1562023-09-14014 September 2023 Final Safety Evaluation for Shielding Topical Report Project stage: Request ML24009A2302024-01-25025 January 2024 Transmittal Email for Verification of - a Version Shielding Topical Report Project stage: Other ML24009A2292024-01-25025 January 2024 NRC Form 896 - Topical Report Verification on the Radiological Fuel Qualification Methodology for Dry Storage Systems Project stage: Other 2023-04-13
[Table View] |
Text
CONVERSATION RECORD NRC FORM 699 (03-2013)
U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 699 (03-2013)
DATE OF SIGNATURE TYPE OF CONVERSATION NAME OF PERSON(S) CONTACTED OR IN CONTACT WITH YOU DATE OF CONTACT ORGANIZATION E-MAIL TELEPHONE INCOMING OUTGOING SUBJECT
SUMMARY
ACTION REQUIRED (IF ANY)
NAME OF PERSON DOCUMENTING CONVERSATION SIGNATURE Page 1 Continue on Page 2 E-MAIL ADDRESS Continue on Page 3 TELEPHONE NUMBER DOCKET NUMBER(S)
LICENSE NUMBER(S)
CONTROL NUMBER(S) of 09/16/2021 Holtec International Clarification Call on RSI Holtec response
Participants:
Holtec: Kim Manzione, Denise Elisio, Stefan Anton, Debu Majumdar, Vadym Makodym NRC: Christian Jacobs, Veronica Wilson, Michel Call, Francis Peduzzi, Tim McCartin, Jonathan Marcano Holtec to provide revised response to RSI-5 to include an updated Appendix D when the RAI responses are due.
Christian Jacobs
Kim Manzione k.manzione@holtec.com (856) 797-0900 72-1014 Shielding MOE FQT Topical Report 2
09/16/2021
SUMMARY
- (Continued from page 1)
NRC FORM 699 (03-2013)
CONVERSATION RECORD (continued)
NRC FORM 699 (03-2013)
U.S. NUCLEAR REGULATORY COMMISSION Page 2 of A clarification call was held on September 16, 2021, with Holtec staff. NRC staff discussed the response that Holtec provided to RSI-5. In addition, NRC staff provided an example qualification report (attached) to facilitate the discussion.
Holtec responded accordingly below and agreed to provide the following supplemental informaton:
- Revise the response to RSI-5 to include an updated Appendix D including information similar to the example provided by NRC staff.
Any correspondence or transmittal of supplemental information should include the following:
CAC: A33009 Docket: 72-1014 EPID: L-2021-LLT-0003 2
ACTION REQUIRED (Continued from page 1)
NRC FORM 699 (03-2013)
CONVERSATION RECORD (continued)
NRC FORM 699 (03-2013)
U.S. NUCLEAR REGULATORY COMMISSION Page 3 of