ML22278A895

From kanterella
Jump to navigation Jump to search
Rev. 21 to Updated Final Safety Analysis Report, Drawing M-43, Sheet 3, Rev. 27, P&ID Reactor Recirculation Pump
ML22278A895
Person / Time
Site: Limerick  
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A895 (1)


Text

H G

F E

D c

B A

c

!O 8

8031-M-43 SH. 3 OF I

~---

LINE DESI GNAT ION FOR VENTS AND DRAINS LOOP 'A' LOOP 'B'

¥,* OCA-271

¥,* DCA-272

¥.* OCA-213

%" OCA-274 1'4 OCA-275 11" OCA-276

%* OCA-277

-279

-280

-281

-282

-283

-284

-285 I

I i-------

1 I

129-~6 l 4 ~

INOTE 3 ll I I I I I -

I I I I I L _

I I

I I

C614 EIE 036 204 NOTE 30 C6!4 E/E 036 2D5 NOTE 30 C614 EIE 036 DETAIL C 206 NOTE 30_

THRU A2909 C3------------i 1-i~=m~8;: ~f;: ~~;

~

NOTES 3 & 4 I

r-

,- - - - - - - - - - - "fERMiNAL "sox --- -

CB02A

~- -

-J20;~6i'~1- -

O£D

<NOTE 311 I I I CG14 111 E/E I I~ 036 I I 201 NOTE 3(

I I C614 II~

I LWJ;;o-;-E 3<

I I

C614 t-f-

~l I-L I

I E/E I

LOOP A ONLY, 036 I

I SfgR DCci~~L BC

?03 NOTE 30 1 __ -

1 C006 TEST

(;!\* r.1 2R001 A M

2F003A C227

~

/

~

C602 7

I 6

PRIMARY CONTAINMENT 20" OCA-205 NOTE 11.-

TO RHR *<.<:::* JMt*]sI1 ~~..,;;,;.;;;_;,;;.;ji;;

_;_;;j_~.......

ISH.7 F,81 1

I

/...._ _____ __

REACTOR PiffiURE

~

5 I

(

/;;;;j.i.. -.........

.;'~2*,.-~*;;......... ~

D

~-

0

~

12'-*

~}oil..

_1-4..........................

17

~:1-o-~lll-4:....... :..

-*2-*..

--.. *..... -........ 9-1 81-.. :1-.. _....

_.;'.=,2*,.-.. *;;...*

_--.. *.. ::::~.-© 7

~:.....

t-1-"'"4..,:'~2*,.-~*:..*--**-t NN*'11 Q

12'-*

~}oil*~*~-.... -..

_~_....... _

I 2F059 4

12"JJCA-2Q4 I

FROM RHR M-51 <.

ISH.7 F.71 20* - *-

C602 C601 ['D R~6

<§>---.--Oi

~ '

I

/

N~

AC I

I

-~~~~---

HV 2F019 ISH.3 0,31

¥,* DCA-234 12* OCA-204 FROM RHR M-51 TO G_.:..ocA~~o1

.!!DTE 11....... _

1 N

REACTOR WATER <C* 1'M:::-4~4c;~-~;.;.,...

__ o41_.,;;_.;;,..... 9°Tt iji CLEAN-UP ISH.3 E.8>

M-54*5:-2 ~

lSH.S E,21

.,.1

-=~---._.. __..,_.;2*8..

  • ~._*_,_.. _..

__ 4_.-[~

28'-*

la

,..-------... -:im--.......................... ""~

~

12*-*

~1-..

~I-*--*.;.;.._.;_;...........

e i

~2"D8A-214 t----M-561-2 M-544*2->----

~~

i

~

~ -------- 2* DCA-213

~

4

~r~V 2y,*ocA:213

_<<_=*.~s~~::!:::~B=.~~1Et_~_~D-*CA~-:!2!:.~** __.L_.,

_:[)-_"4_t-_-_.. -._-,.:.2~

~o;::c~A:::-2:tl~3-.... 2~F~:~*2t9*HI -2.;,.

0.. 3-0--2*~*~t2---ll ~

CB02A ll<

~C 60Z ORYWELL EQUIPMENT A

VS O

-TO PUMP B (00) DRAIN TANK M-61 250A p


,I I

I -

N_QT~ 2 J6A iwECTH ~2A

  • r

I

~

VIBRATION HBO SBD


,I I

... A,

~LUBE

~* ¥.* SB0-243 -

Eg~r~5f~T

~C802A

-1


,I


1 I I


1 I

I

---1 1

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I -

I i

I I

I I

I I

I I

I I

I I

I I

I I

I

-.i..---'~

OIL I

2F007A VENT DRAIN TANK A

TE,_ ____ _,P I

© M-61 251 A 810 82

~

UPPER 2~6A - ~

I BEARING LSHL I

fii\*

RI*

I I

I r.1

,.L, 250A IIV*2F250A.2 r -

2NO.OIA 2

I y

R S

. I I

I N004A TO REACTOR I

I I

I

~:

VN~

I--~

I I

y

~

co5N~~gs~~~ER I

I I

I n"TUBE-f------

Jl*H~C-291 I Z"HBC-291 L

I I

I L

TE ll<

~

i5 ~~~


.-------rt,- NOTE 10 l--~::1':IT:::::>

1 I l

252A Ci,C 2 i; ~~

~*

: __fri\*

CSH.2 H,7)

~_j-r* ~SI~ i::

¥.*

~

I I r 2N009A

~8ri~1~GWI~{~~

TE J

"- °'- I 11 2033

~.

I I

I y

TO I

I 253A >----<

AIR '-- ~oz§.' I

~

I 3* HBD-41 e CHILLED 0

E F

r--- :"'!---------------------

M-S7

/*WATER l

1----

l*

1 COOLER I I~~

I I

I

<SH.10 H,3)

SEE ~1:::::1

~ -

I I

I 3* HB0-4 l6 0Eii1~ C I~- -

2~~At----l i-.--~:r""----.... t---------------

~C~~~~D 2BP201 I

D,. E,, F3/

_, ~

u 0 I I

I I

<SH.10 G,3l WATER 3

.l C006 r~ ~

PT L* __ j_ _ _JL___.<:'.Sil-~;-1:.::(:J~~-------,-----

2NOOSA

~

J:'

OCAZ~

~*

I I ORYWELL EQUIPMENT DRAIN TANK M-61


_I -

TE D4. F" 4 I

......,,,.~

~ f5 '~* i L;:r I I I

~- _ _ _

TE

':;~

LI I

I COOLING WATER I

255A E, lf

~~-

A6A 256A I

I I

MOTOR OIL

~

257 A G1.G2

~L&J

%'HBC-291 I

I I

2'HBC-291

~~ ~1"'11---..----------...... 1--------

F'ROM REACTOR ENCLOSURE COOLING WATER

. ~~~,.

N

~.

C006 TEST fxn TTsT C602 COOS

~

/

'\

l.!.J 0,R6ci2A~ r.1 2.FJOD4A-.:d;

~

PT*

2 I

1*

~

2~A)-_ _l __

l:.L-;"'~l~.'..::;~C*A....,-2F~OO.OOQ66A'\=A}::::::......----------,

-~

~~...J7 N

~

RECIRCULATION xv C227 203A R"o~ -

~ "

PUM; ~::~ PURGE ¥,* DCD-210 ocD+-;cA ISH.2 A.21 4:

~ g N

~

~ 0 2 l.!.J TEST

~

l.!.J TEST TEST

f ::

2 TEST r.1 C227 ~r R'-o/

G RECIRCULATION

/

PUMP SEAL PURGE ¥,* DCD-210 IC

u l<:-'

2~

> M-46 lSH.2 A.21 OCD:;J;CA

~ g N

HA S-l C602 l.!.J TEST

~

C228 C022 TEST Y '- /.

(;!\* r.l L -0 R 2R001B ""-'

~

I /

~

  • 1*

2004A gt =-*

~

~i--

N

~*

L!J DRAIN I'

-1i..

2014A

,..._,. x r.*

~ ~

N l.!.J NOTE 16 TEST 1

~*"'T--D*-*'"l-"'T'~*~o~CA~-~4~13:.......,

~ ~

2 l.!.J TEST

~*-

C022 T

~

i PT ll!

I" - ~

2eB

-;d2=0DSB 1*


DCA TEST!::

t14 X-63

<Hl (L)

L~

FD 203A (LJ\*

¥.* HBD-418 Cj-' I o/.'

I I

I C802A

~

NOTE 15

~ il-4-IMl-CJ--

~

I I

I

~-T

"~

~ -@' - ~ y, ~- ~-m 1-._...... --r-.......... J--tr;,...,,r_ ~-~.. ~~~~_*_N ___ ;,,._~L.:.J-~_:. -Tus-E~

~

y,-Hsc-425J r ~

.,,. ~

'l'.

w HBC-425 y,- HBC-425 t%

~

~ I.+

I I

I :llt- _"-SEAL LEAK uo, odlON -

. NOTE 10 l<i"'v"v1 1

,_ 'f" ~

'f" ~

T LT I J:

M-561-2--r I/,

I/,

llV-2F257A.2 257A I

I I i;5

~

l+..._....__ll _ _........._-t SEE DETAIL A FOR LOOP B I

I l "- __ LZ_ - - - - - - - - - - - - - - - - - - - - -

COOLING WATER VENT VALVES I

I

<..)

r.l I

IlA S§ C802A

,c--...*

~~~...'.Y.::.HBC-291 U;!

~AHL _ JFS.HL' TE ~

j 1 -

1 du*

~"'

,,. 207A 2N007A 258A

"-0 I I

I

. _, \_Y2 x 74'

~

o H1,H 2

io I

ll<

I

~

..i:

Y:_2* HBC-423 N

¥.t*HBC-423 ~

~~u 1' HBC-291 I

TE I

t'i

'h"HBC-423

~:~-

ilz;:i~t"1 I

I 2N003A I

I A L~P ONLY, NOTE 10

~

T~

§~~I~

I

~

I l' DCA-226 SEE DETAIL B

,*" DCA-228 M-5*61*2~

~~&

t"1 1* HBC-291 I

I 1

1 1 1 NQ 2 SEAL Nu~ I 1

1 1

I I l - - - - - - - - - - - - -

~

BECHTEL GE CAVITY

~~~~*

HBC-291 I

I I

REF. I

~ ~.~.~ ----------,, -\:;:.;;:_ r-+-

9 c,,, :-,= = = =-= = = = ~ J : I :] !

~ -

i

_ Z BECH_J --

NQ l SEAL

~ ~-------------------...1_ -

.J. - ~

L.

'"l I

l I

~

~

CAVITY I

I I

I l' DCA-412 1

.......i ~

I I

I I

M I

A~002 A4004 SEALS11 CODLING WATER M*O <

<SH.2 G,71 Y,* SBD-243 VENT t ORW I

I I

I I

I

©

© Y.'SBD-243 1------- 3-----@-

[-

/' ~

~ 5 ~ rt ' ~HSC201 I I

I

~~"'

7 J,, J, I

I I

1 (H;\*

  • ~*

V/

I I

I N

0

~

I I

I I

I 2f0ll~A.\

.'Q'

~

t
:. I~ /"~* OCA-272 <31Al I

~

Y,- DCA-280 131BI

2~

2"':

T 23A-2 Ill

~

~ =

1111 1

1(!

10 0

g ORW I

I I

~ ~

2AP201

  • 28" -
  • 28' x 24" x 28" I"...,

~

C602 I C20 I I I

I

)1 >

I I

I I

"' ~S

~SS I

I I

REACTOR

"'\.

I I

I I

~1::"1.':'"1-c;::J-;:IH'::l-'_ fg\

l; "1

~~

~ IZlA*I 291 I

I I

l.!.J RECIRULATION

\

(

I I

I I

W OCA-271 __.,

/' l..V

~ ~ <<:;

I I

I PUIAP I

I I

I Y,* HBB-243 2-< -

Y.*

= ~

~

~

L9i-... --tllf---'.:...;;:;;;;...;;.."'-jl

  • ~*...

~

~

M -

-._ - 1 -

~ -

- t- -

- 1 1 2F036A. 2F09:7 l

l; :;!

E;l I

I l -

- I* -

...I I

I DCA HBB DRYWELL EQUIPMENT lD g

t-]

I l--------------------1*-

_________ _JI DRAINTANKM-61 2a*x""'2**4**-x*~-a-.-""". ~ ";;,.

l _ ~~-~~

- ~

- - - - - - - - - ~

~*~

~"

IHI -

(Ll

~

~

~ ~'-..../

'-..../ ~ C60~

' ~

I

~

I o

~._[§]_*I

-SFROM*N.n I

l<:

h\

7

~

I

~ ~

~Q1Nr 2 ~

pQlNi- ]

2K640B ~ ~

I VJ..,.

r---1

~

q:

I I ~h* LJ ~

--j gf N ~ h, I 2,.(ISH.~-~:6;

~02

~.s:--:-:,,.:-_,;;3:--' 0 iSH.'4 0 0 71 l' DCA-230

~

' H j v 1!'*1~ I 'i,'i~ ii II' "ii : ~ -s-,,_ *~-I""]

~ ~

i

~ -J 11* DRAIN 28, _ * '-

~.,

1:

?Nf>OIA c:0 BAR

. '\.

l;

~

1

~PLUG:

U\

TO DR~WELL EQUIPMENT Q

Q I

HV *

'ii DRAIN TANK M-61

~

~

TO DRYWELL EQUIPMENT I 2~8

~

~

DRA[N TANK M-61 I

I 2

, Fcl \ 1 r 1sH.1 H.s>

Z~O~O ~ \__ }'2° S.S. TUBING

<EI3>

2F2SOB 2F250B, l

__ LSHL L

2508 112' S.S.

erJ l

+

~/8. _J

~-DKl~--l.2~60 llV-2F250B.2 UBE

7

+

2F257B. l erJ LT 2578 3/8". _J TUBE llV-2F257B.2 ADDITION TO DETAIL A 1'8' LOOP ONI. YI DETAIL A DETAIL B 2No"07B

~ ~

~ tr.lg)

Y,* HBC-423 \ I 1

11* HBC-423 ~

¥,* HBC-423

~~Af CAVITY ND NUCLEAR PIPING

~---

DESIGN SPEC.

SEAL STAGING FLOW LOOP B ONLY TEST r.1 C602 DETAIL C TE 2558 o3, E,, r, 0 4

  • E4
  • F4 fxn aill*

2_--.:,FO~A C227 ~

I 8 r

~ ~-1

- REFERENCED DRAWINGS ARE LISTED ON SHEET 4 -

/

~

  • NOTES REFERENCED ON THIS SHEET ARE LISTED ON SHEET 4 -

H G

F E

D c

l'--------..;3::J:cJ-"1;.:D:::C..:A~-~22~4U.-~12**~-_J~ PDT cioG r'"'Tl:'ill-IN_C_O_R_P_. E-C-4-23_3_8_4 _R_E_v_. l_P_E_R-W0_4_7_75_2_3_8 _____,,

J":'T.)Tl'lr1~

  • -h

~

2N015A 27 REMOVED VALVE 2413. IG,2J

,.-,., p f; 2F~69A DC~ '

ADDED AN ADDITION TO DETAIL A. [F-G,l-2J 0 \J B

~

s-1 '"

26~~ i~iD~AL~is 6

\~$:igrflov,;.1" :~8E?1vL-~-s2lA~~ ti: Mi:.~~i1R EJ1 Jc jRn1 Lt*,. "'

DCA m POINTS A4001,2,3,4. rn&E-4l

--i 11-----..;..--~3:::::J:cl....:'...:::

0 c..:A:;i*r-22 5

....-~

-c,;;;;,._--.-:1 25~ 1~~2~6u~~.. c~~2~~~to 0~£?~MdE*~1f.Efff~~c~TT~B~94TJ3 19 EJ< JC"'"'

r-zr~6 9

c* :.*~~,i~oc;:

7 ~*~ @~

l'Y ~~OR;s~~~*~l~-00310 REV.3 PER WO C0258360.0ELETEO

\ *tN G ".t 2411>~ XY-036-218.219,222.XR-036-201,202,Xl-036-201 & 202.

~

/

'\

l.!.J

"' ADDED 20-C614 ANO REF. TO NOTE 31. IE-C,8l.

TEST XV TEST L

UJ 2F0.40C r.lTEST l CJ >-

DESCRIPTION ooo

.~Q..r-w I Q.

c: u"'

~B

<E~

C022 TEST M

~*

r.1 2FOO~B C228

~DRAIN & !-----------_,~,

+--

'----t20..

26-B...,20~27t-B-~ TEST GEt--vw DCA-231 B

BECHTEL

~

28';;.

  • 1----__.;-;_ ______________________________________ --1.::C..

~r.itEs;~0FC6~os"o"Jt~ i q~ ::CHAN! ~~1l'f,m;"\\\\"'!18::1.t S,l;\'\.,,

)Bm G

j,.,.

/ '\

co22 1

P&ID

.!.:,. DCA-m i*

PDT REACTOR RECIRCULATION PUMP 2~;;s

<UNIT 21 2F039B

/\ TgT 0G;~

{ Pl \

Y '- /.

2R002B ~ "'

- -D R C602 C022 y -

  • ~

I /

~

r-t 1----1,. DCA-231 I

....,. SBD-243 ~

2F 00 l B 2F 0028 VENT 0_*

  • I

<f-I1li9

~

2~B <fl.l?b I ~-12F~006B

.1----1

r.,"

--Y,:- T-DCAI

'---2.,t,3*01-e-2-0*~*1~t-1

~-i~l'!!~r:-~-11:1~1'"

43

'"'.~

TEST i::

X-63

.v 20426 D A S D LC 8

I 7

OCJSBO I

I I

HS-2<58 -~

_J

<SH.2 B,31 6

RECIRC LOOP B SAt.IE AS LOOP A UNLESS OTHERWISE SPECIFIED I

I e e I

5 I

I 4

I 3

/~\

0 p.:.ru\~I~ ~~

S-1 JJA

_j_ 1*,. nr.~o*

NDCA

_,_ 1 DCA 227

~0390 I'

I Ji xv 2Fo4oD

~C2Z~045D

/

~

2 1---------L-IM-ER-l-CK __

GE_NE_R_A_T_ING __

S_T-AT-IO-N--------~A EXELON NUCLEAR CORP, SCALE I

DRAWN I

!GOS I CHECKED (INSPECTED( APPROVED I DATE NONE I BECHTEL I BECHTEL I BECHTEL I BECHTEL !BECH I BECH 11110919<

APPROVED BECHTEL SHEET 3 OF I 8031-M-43 m 27 I CATEGORY A 1