N
....=
- c
~
Ill v
I
- ?1 H
G E
0 c
B A
8 8031-M-45 FROM RWCUS NON-REGENERATIVE 1£AT EXCHANGER 11-44 ISH.4 A,41
'Y SH. 2 OF l'SBD-245 VENT DRW :?
TO Cl..EANUP BACKWASH RECElVING TANK 3" 111e-210 _J L 11-66 ISH.1 H.31
-, r 8
1 11-15 ISH.27 F,51 4'ECC-202 ISH.21 G,41 HV2-32AIASI NOTE 10 1' SBD-245 T.
I' 2'ECC-202 2026A 2025A l'ECC-212 N
~'.
NO
~
NOTE 1 2-37A I'
£.
NOTE 3
@CO:t~s 1
2' 6
C092
@!-r---::-
NOTE 101 11 1%'
11 1%'
11 1%'
g N
l!.J 2' lllC-231 l'SBD-245 FC CLEANUP Fn.TER DEMiiiRAliZER 2AF203*
aoon 1
I I
6 1'
1' I'
~l'SBD-245 llANI I
VENT 20258 20268 5
TO Cl..EANUP BACKWASH RECElVING TANK
... z ii 4
3 2
REF.
Ill.
GE t<<l.
REFERENCE DRAWJNG BECHTB. t<<l.
REACTOR WATER ClEAIHlP SYSTBI P
- I D 8031-M1-G31-101001.
729E607AD 2
REACTOR WATER ClEAIHlP SYSTBI FCD 8031-Ml-G31-1020*fl. 729E608AD 3
PROCESS INS'IRIJMEllT PIPING AND TlllING DESIGN SPECIFICATION 8031-M-1-A61-4070L1 22A2864 4
REACTOR WATER ClEAIHlP FILTER/DElllNERALIZER P
- ID 8031-M-1-G31-ZOOIDI 761E397
-- -- -- -- -- -- -- -- -- -- -- -- --------------1 5
PROCESS SAll'lING 8031-M-23-SHT. 1 FC 1
t-*-tlt-3 VENT 2057A 2058A 1-r aoou DRW 4'11lC*260 4' lllC-260 2' lllC-244 2' lllC-244 I
l'SBD-245 VENT 5
FG 256
_J~
-, r-'fl 1 lllC-210 2' lllC-232 4'ECC-202 HV2-28!ASI
~
ISH.27 F,51 HV2-07BIASI
<f"':
l
~~fx ISH.27 F,61 HV2-13BIASI I
1 1"
20248 20238
_69
,~
1--i 2' 111e-231 I
VENT r.l 2*308 NOTE 9 I NO~TE9 L
11-544-2 6
P
- ID LEGENl 8031-M-OO I
RWCU FILTER/llElllNERAL OPERATING INS1RUCTIONS 8031-M-G31-ZOOIKI.
3249-334-2 8
INS'IRIJMEllT INSTALLATION OETAll.S 8031-M-830 L
~~
-- --------....------ -- --1
- 18. THE ACTUATOR FOR VALVE HV-45-2-19 IS PROVIDED llITll A MAllJAL STOP TO I. THE GE llPl llJllBEll FDR THIS SYSTEM IS G31-Z001.
CLEANUP Fn.TER DEMitiiiAUzER 2BF203*
aoon 1'
I' SE1 THE ~TE ONCE T1£ VALVE
- 2. ALL INS'IRIJMEllT PIPING AND TlllING SHALL BE INSTALLED IN C092 IS TllROTllED TO A POSITIDIL ACCORDANCE llITll REFERENCE 3. FDR DEVIATIONS TO SLOPE 119.ASIE BOIHIARIES SHOWN DN THIS IJRAllDIG CRITERIA SEE REFERENCE 8.
ARE FDR REFERENCE DNLY. SEE ASIE PIPING
- 3. ALL PIPING llILL BE ARRANGED SUCH THAT THE VALVES
~I SPECIFICATIONS FDR ADDITIDNAL INFORllATIDN.
INDICATED CAN BE OPERATED BY REllllTE MAllJAL OPERATORS.
!!! o-
DN SUCTION AND DISCllARCE lllZZLES.
2
~I S. PRECOAT TANK IS SUPPlIEll llITll ISO-FLAT FACE FLANGES.
"'!!!; I
- 6. THE ClEAIHlP FILTER DEM1llERALIZ£R SYSTEM IS A SEISMIC CLASS ll SYSTEM. ALL VALVES. EOUIPloENT AND INS'IRIJMEllTATION INDICATED llITll AN ASTERISK._. ARE CLASS ll SEISMIC AS
'1 SUPPlIEllMGE.
"- ~
- 1. THESE INS'IRIJMEllTS ARE NOT llJClEAR CLASS DEVICES.
I I
I I
I I
1'*
1'*
I t-*-t~3 VENT 20518 20588 I
C092 I
@*-i I
- 8. FDR llD..lIPORE FILTER HOLDER DETAR. SEE REFERENCE 5.
- 9. INSTALL THESE VALVES llITll THE 11'<<.ET SIDE OF THE VALVE TOWARD THE ClEAIHlP FILTER llEllINERALIZER REASON: VALVES HAVE BACK-PRESSURE LillITATlDllS.
- 10.
- 11. DESIGN. FABRICATIDll. llATERIAL PRDClllEllENT, ERECTION AND TESTING FDR ALL PIPING. VALVES AND EDUIPllENT SHOWN llITllIN THE SYMBOL (+. NOTE l1l DN THIS PMD llAY BE IN ACCORDANCE llITll THE REQUIREllENTS OF THE PIPING CLASS DESIGNATIDll. DESIGN CODE 'D", llITll THE FOLLDllDIG EXCEPTIDI&
SHALL BE PER THE ORIGINAL
~
USED SHALL BE AS THE ORIGINAL LINE CLASS DESIGNATIDN.
- 12. DRAIN POT TO BE 3 FEET MINillJll.
- 13. DELETED.
- 14. FDR ALL NON-SEISMIC CATEGORY I CAPPED VENTS. DRAINS.
TEST CONIECTIONS AND Cl£llICAL CLEANING CONIECTillNSo DESIGN. FABRICATIDll. llATERIAL PROCIHllENT, ERECTION AND TESTING FOR ALL PIPING llOllll5TREAll OF THE LAST ISDLATIDN VALVE. MAY BE IN ACCORDANCE WITH DESIGN CLASS D.,
TD Cl..EANUP BACKWASH RECElVING TANK 11-66 i
I r i
!SH.I ~
~ :::-1~
~-1-~-
____ ::'.__J ISH.27 F,61 TD PROCESS SAll'lING
~*
lot-23 ISH.1 11,21
~( ~caom
~! ;ii::I
~
NOTE~ 11-544-2 TO CLEANUP BACKWASH
~
~ANK
'lllC-210 w*
- 1*
ISH.I ~
I r NOTE 3 2-42B 2-438 3"ECC-203 FC l'HCD-208 lot-15 HV2-20IASl ISH.27 F,41
~
v
~
REACTOR WATER
<~~~~-----J CLEAN UP BACKWASH 11-66 RECElVING TANK ISH.l ~
4 HV2*14BIASI IO iii 11%'
J..
I
--- __ _J ___ ---- ----1 I
J l'ECC-203 2-4~
I I
__£_~Hi&-, <N I
I l'ECC-209 s'
_j _________ l ___ J L ___ -r-£ I L __
f 2' lllC-244 TO PROCESS SAll'lING INCORP. IR 1598046 PER ACIT 03.
ADDED 'FAll. CUlSED" TO HV-2-1411.
[1:,3].
INCORP. ECR 98-01386 REV. 0.
REllllVED VAL YES PSV-2-62Allll.
[1:,3]. m.n.
TO RWCS-REGEIERATIVE 1£AT EXCHANGER ADDED NOTATION 'CATEGORY Al' BEi.OW TITLE BLOCK.
DESCRIPTION TABLE OF ADDITIONS
- CHANGES USE DNLY PRINTS SHOllDIG LATEST DATE MECHANICAL P&ID CLEAN UP FILTER DEMINERALIZER
<UNIT 2>
LIMERICK GENERATING STATION EXELON NUCLEAR CORP.
NONE BECHTEL BECHTEL BECHTEL BECHTEL L------<~lot-OBE§![:~ CONDENSATE SYSTEM ISH.3 c,31 APPRll1IEI BECHTEL SHEET 2 OF 3
2 I CATEGORY A1 H
G F
E D
c A