Rev. 21 to Updated Final Safety Analysis Report, Drawing M-70, Sheet 2, Rev. 33, P&ID Gaseous Ambient Charcoal Treatment
ML22278A822
Person / Time
Site: Limerick  
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A822 (1)


Text

N 0

I-I (/)

0 f'-

1

~

H G

F E

D c

B A

8 8031-M-70 SH. 2 OF 6' EB0-125 M-70

!SH.I H,5)

I I

I 4' EBD-125 7

4' 1149 L!J DRAIN NOTE 5 4'

1128 6

1186 1111 4' EB0-125 L_ ____________________ l Nz PURGE IL*

~M:lIT::::::>-~*:'HB~D-r8~6:.._-tii"if.--(~P~<..

UNIT 1

"' M-57 CONNECTION

<SH.I H,61 1181 M-70 TO 1120 4' EB0-125

c~

C352 C873 EI¥-

I

4 -

I C352 I

-1 I

I I

110-cmf- - - - - r

<NOTE 19l I

352 4

L!J DRAIN NOTE 5 5

1122j

~

r+.,87,3 W

~~

~

C352 I

C352 Nz PURGE IN 4'

1125

~~

~ CB73 fTAH 1 I

~2~

I C352 I

EJ{ifT

  • I 130 I C352 I _,

I I

I

~-----r I

@352 I

Tl*

I 130 I

I L.j10-C673l

!NOTE 19)

CHARCOAL ADSORBERS I

-~---

I~ ---+-----~

I

!SH.1 E.Bl TO FR-69-115 I CJ52 0

C582 FT

  • 150 4

~

L!.J C873 I

@l-.J

~'- i GP' I C352 I _,

I I

I

.----1 I

@52 I

TI

  • I 136 I

I L.j1D-C6T3l

!NOTE 191

~

ffi

~

~ ~

L!.J DOP TEST TAP Yz' Y.' HBD-86 r.1 1182

g

~

~; 6 4'X 6' VENT r.l OUTLET HEPA FILTER 10F371*

TURBINE 6' EBD-125 4'

4' EBD-125 ENCLDSURE*.....................................,,....

~C'l<>l---"1"".... -i!..........................,............. -t~~~J-----------------------------------"-------.,...

"'[c;~--------------..,111(~

NO~\HAtKENT 1206 NOTE 1 1135 4'

~ ~

L!J DRAIN NOTE 5 C873

~

~

C352 _J

~

~

3 L!.J DRAIN NOTE 5 DOP TEST TAP ril W HBD-86 Y.'

Y.,*

t---.--ti*<J.... N, ~lfGE 4'

1138 1180 4'

L!J DRAIN NOTE 5 2

I I

I 1134

_J L

VENDOR SUPPLIED PACKAGE 8

RADWASTE ENCLOSURE VENTILATION SYSTEM r

I I

I l

C3D5

~

1' OFFGAS ENCLOSURE FLOOR DRAIN SUMP OOPSOO 7

1 Y,*

1111 1wx 2*

1146 6

TO 4' HBD-163 M-61 M-15 ISH.2 H,11

<SH.36 H,1>

5 C873

~

~

h>F--#-->, NOTE I VALVE SEAL AIR HEADER 4

3 2

NOTES:

1.

SEAL AIR SUPPLIED TO STEMS OF ALL PROCESS ANO DRAIN PLUG VALVES, \4' FNPT.

2.

AIR VENT IS FLOAT OPERATED.

3. DELETED.
4. RAOWASTE PIPING IS LIMITED TO THOSE LINES DESIGNATED DBO AND EBO.
5.

VENTS AND DRAINS LOCATED ON CHARCOAL ADSORBER TANKS ANO CONNECTING PIPING WILL BE SEAL WELDED CLOSED FOLLOWING HYDRO TEST ANO PRIOR TO LEAK TESTING IN ACCORDANCE WITH ANSI/ANS-55.4-1979.

G.

PACKLESS DESIGN.

7.

3' SCHEDULE 160, 12 PIPE DIAMETERS IN LENGTH.

8. SPOOL PIECE WILL BE LEFT IN PLACE DURING OPERATION, OPEN PORTION OF SPECTACLE Bl.IND FLANGE IS INSTALLED DURING NORMAL OPERATION.
9.

CL YCOL MUST BE TESTED FOR PH PERIODICALLY ANO THE INHIBITOR

RENEWED,
10. DRAIN PDT SHALL BE AS DEEP AS ALLOWED BY PIPING SLOPES INDICATED.
11. LINES 1' HCD-125 AND'l'.o' HCD-126 SHOULD BE SCHEDULE 80 FOR HYDROGEN DETONATION CONSIDERATIONS,
12. HOSE CONNECTION IS TO BE LOCATED CLOSE TO UNITS I ANO 2 GLYCOL SKIDS. VALVE 0005 IS TO BE LOCATED BY THE HOSE CONNECTION.
13. VALVE CV-174 IS TO FAIL TO CHEt.tlCAL WASTE TANK ON LOSS OF POWER, FAIL-AS-IS DN LOSS DF AIR. DISCHARGE TO CHEMICAL WASTE IS TO BE LOCATED o HIGHEST VALVE DISCHARGE POINT.
14. GLYCOL SYSTEM VENTS AND DRAINS MUST DISCHARGE WITHIN CURBED BOUNDARY BENEATH GLYCOL EQUIPMENT.
15. DELETED.

16, DELETED.

17. 6' EBD-125 SHALL BE HEAT TRACED UPSTREAM OF ME-117 BUT NO CLOSER THAN 10 FT MINIMUM DOWNSTREAM OF TE-116.

SELF LIMITING HEAT TRACING RATED AT 250D WATTS SHALL MAINTAIN GAS TEMPERATURE AT 60"F MIN!Mllt.t.

18. VALVES 1147 ANO 2147 ARE OPERATED IN Slt.tULTANEOUS ACTION THAT IS CAUSED BY A U-.DINT REACH ROD MECHANISM.
19. POINT CONNECTIONS SHOWN ON DRAWING M-207-00274 SH.2.

INCORP. ECR 02-00558 REV.I PER WO C0205707. DELETED TR-70-124 FROM IA THRU G-S371. ADDED XY-036-124, XR-036-101,102 & XJ-036-101,102 TO IA THRU G-5371.

[E-G,2-61 INCORP. ECR 94-06862 REV. 1.

31 ~ ~~Ff TRANSMITTER FIT-150 UJ 0 >-

z <(

0 DESCRIPTION TABLE OF ADDITIONS & CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID GASEOUS RADWASTE AMBIENT CHARCOAL TREATMENT (UNIT 1 AND COMMON>

H G

F E

D c

t------L-1-ME_R_IC_K_G_E-NER_A_T_rn_G_S_T_A_Tl-ON ____,A EXELON NUCLEAR CORP.

SCALE DRAWN

!COS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 1518 APPROVED BECHTEL APPROVED SHEET 2 OF 8031-M-70 33 I CATEGORY A 1

_J