{{#Wiki_filter:H G F E D c B A 8 1 6 5 4 8031-M-69 SH. 4 INSIDE SlllEUl WALLiWTSlllE r---~--~--~--~--~--~--~--~--~--~--~--r---~--~--~--~--~--~--~--~--~-~--~--~--~--~--~. .---~--~--~--~-~--~--~--~--~--~--~--~--~--~--~--~--~---. ~~i I ,----------ti :t-,~-3~-------------4~) I ~--------~-.-i-- ~ SAlol'l.E RElUlN I i 1 / \. / \. 1 TO XA-243 c::-+--L......b<l-.....---...:...1 - I
- ! 131 !
.----~---------+
~-r~---~
~ r-------~ i _j' 141 '/,I/ J r--------t-s TOAR-243
+-
-+----. ~ ~ l'ii'i I ~ i / \. / "\. r-- - T ---:. 5 TO AAlll-243 ! -L @*Y _J I b1i ! I NDTE29 _J / \. I i 243 243 ---@--- ~ --t 5 TO AAH-243 21ti2 2163 r~--~--~--~--~--~--~-- 1 UOUIO VOLllE lolllSTIJlE I 1 I 4
- 6.
1 i J J '"Ii i 3
- TRAP SIJIGE TANK SEPARATOR:
UOUID DRAIN.,_-!------1/'t-------l"'.I 2183 I I !...--~--~--~--~--~--~--_J SIJIGE TANK ~y 120T440l -i----'---.~..t____ pty AI \. I I I I 2211 243 / I --:---V'!---l_1=--t-~ 161:t_Jo 1 --<~I FE I SPAN GAS I I 22112177 I FC 2167 ClllUED WATER OUT..... !----D<I-----,;_------~ m I i I 2171 ClllUED WATER IN 'r-i----D<l--------------1 SAMPLE INLET UPSTREAM OF RECOMBDER 2170 2158 TE I i. 219 I I I I L......:l:._ __ ~1---.... +---_,~ ZERO GAS --1-----------------,-----~-+-~-----@ ~-FC@ 2168 L _________ _i ___ i_1-!!!_I ___ @ -6P 3 I: I ~ ~ I I 191 I I ~* INSTRlllEllT AIR NDRMALSAllPLE1NLETr-j!-~~f><3~~~-{:.i::J-~~~....IL....~~~....l~~~~~~~~~~~~~~~~~-l)'l--~~~~~~~--1~--::i::==:::El~~~~~~~~~~~~~~~~::...... f4-~~~~~~~~~~-f~3FORPURGE 2157 FC 2159 I I FC 2169 I I. SWAGELOK I TI.l!E FITTING ! READOUT Atl) aJNTROI.. MODULE. 20C163 I i I I --~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~-' i l-~--~--~--~--~--~--~--~--~--~--~--~--~--~--~-~--~--~-! r---~--~--~--~--~--~--~--~--~--~--~~--~--~--~--~--~--~--~--~--~--~--~--~--~--~--~. i r---~--~--~--~--~--~--~--~--~--~--~--~--~--~--~~~--~--~ ANAL YlER MODILE. 20C162 I
+-L_-+-----------
~----------_J-~ PUMP TEST COllECTIONi 1 11 ~ 1 --------------- - - - +--+ ~ t-- - - - ---- -26DAAI:~ ~ -- ----i- -r~> ~"FNGS I r--1 ------------11-1------.--~ -1 @T'--'~"--------------t_J1-~ I I I '/ "\. / L __£-------- --~ I ~---------l--,_El+-JRi R } ISH.110.11 8 SAllPLERElUlN 1 P" /,
r-s I
I I I I 2162A lr~--~--~--~--~--~--~6!~ 1 1 UQUJD VOLUME llJISTURE I
- TRAP SURGE TANK SEPARATOR l UQIJID DRAIN 'r-+------1/~---+I 2t10A 21628 21108 1
I I Ol I .---------------H TOXA-243
,--:-,-----+
I @ r-------~ 6 ! 141
- ~,I/
I @ J,------f-5 TOAR-243 ---r--r~ ~ ~ 1 Q I I I / "\. / "\. 43A ~ -T-+5 TUAAlll-243 i i i ~L @ _J I b1i i I 1 I N0TE29 ~ _j / "\. I i
- ,. 2i:s
~ ---+ 5 TO AAH-243 I I I i J © '-6./.. I 1(5)1 ,@AI R -i---11-1--- 43A / "\. I I (6) I I ~~r---::1:'.'."..1:--......,ljl::::::t:==q-~<(i~~:--~~~~~~~~~..-~;-~~~~~~t-~~-t-lj SPANGAS I FC 2167A 5 4 I t-FC I t---@ ZERO GAS 2168A 21688 3 X Dz o2 LOW ~HIGH ~ lllJNlTIJR TROtlllE ~HIGH SPAN GAS TO H2 ANAL YlERS ~ lllJNlTIJR TROtlllE 2 ISH.3 G.21 M-69 ISH.3 0.61 M-69 ISH.3 A,61 2 NOTES: I. 2' D£CONTAMINATIDN WASH CONNECTIONS.
- 2. FLEXIBLE CABLE CONTROLS GASHOLDER BYPASS VALVE.
- 3. THIS ANAL VZER NllRMALL Y SAllPLES OO'INSlREAM OF AFTERCONllENSER
- 4. PACICLESS OESIGN.
- 5. llELETEI>.
- 6. llllEE-WAY VALVE TO BE LOCATED AT PIPlllG LOW POINT.
- 7. 24' HBD-272 MUST BE AT LEAST 6 FEET LONG Alll LOCATED BELOW TIE AFTERCONDENSER AIR COOLER DRAIN.
- 8. DESIGN,. FABRICA TIDN, MATERIAL PROallENENT, ERECTION AND TESTING FOR ALL PIPING Alll VALVES SHllllN ON THIS P&ID MAY BE IN ACCORDANCE WITH TIE REOWREIENTS OF TIE PIPING CLASS D£SIGNATIDN, D£SIGN COD£ 'II' WITH TIE FOLLOWING EXCEPTIONS; lal CLEANING REOOIREllENTS SHALL BE PER TIE ORIGINAL LINE CLASS DESIGNATION.
lbl WEI.DING PROCEDURES TO BE USED SHALL BE AS REllll1REll PER TIE ORIGINAL LDE CLASS DESIGNATION.
- 9. VALVE BODY MATERIAL IS AISI 316 SS.
- 10. !EAT TRACING TROUBLE ALARM LOCATED ON C873.
- 11. LOOP SEAL DISCHARGE LINE lol.JST BE AT LEAST 11'-9' FROU T1£ BOTTOM OF T1£ LOOP SEAL.
- 12. REDINlANT !EAT TRACING SHALL BE INSTALLED.
- 13. LG-202. YS-217, F0-217, VALVES 2141, 2080, 2131, 2132.
CE-2SS, FG-255 Alll SX-255 ALL TO BE LOCATED IN SPARE RECOMBINER ROOM.
- 14. REDINlANT !EAT TRACING ANO CONTROL CTE-206A &. Bl TO BE INSTALLED ON GCC-202.
- 15. TE-206 A &. B AND TE-207 ARE MAGNETIC SIJIFACE lllllT TYPE.
- 16. DELETEO.
- 17. DELETEO.
- 18. DENOTES PROCESS RAOIATJDN lllJNlTIJRING SEE P&.ID U-26 FOR D£TAD.S.
- 19. DELETEO.
20.. AFTERCONDENSEIVHOLOl.P PIPE LOOP SEALS TO BE INSTALLED IN REACTOR ENClllSURE EOUIPMENT DRAIN SUMP.
- 21. DELETED.
- 22. DELETED.
- 23. K SIZE CYLINDERS ARE TO BE MOUNTEll YERTICALL Y, SUPPORTS REllll1REll. H2 CDNNECTlllHS ANO SAFETY RELIEF VAL YES ARE TO BE AT LEAST 3 FEET FROU ELECTRICAL WIRING OR EQUIPMENT.
RELIEF VALVE DISCHARGE TO BE UPWARDS TOWARD OPEN AREAS AWAY FRDM BOTTI.ES. ADJACENT STRUCTURES ANO PERSONNEL.
- 24. FITTINGS FOR T1£ REGILATORS Alll MANIFOLDS SllOLUl BE STANDARD LINDE OR EQUIVALENT.
- 25. CONNECT 080-219 AS CLOSE AS POSSIBLE TU VALVE 211ti IN GCC-206.
- 26. DELETEO.
- 27. DELETEO.
- 28. DELETEO.
- 29. llSS-243 IS PART OF AIT-243.
llSS-243A IS PART OF AIT-243A. llSS-2438 IS PART OF AIT-24311. 3G. PSV-240 INLET El.BOW AND THE ATTACHED !'LANGE ARE STAINLESS STEEL. <<ECR 98-024431
- 31. POINT CONNECTIONS ARE SHllllN ON DRAlllNG M-207-CI0218 SIL2.
ZERO GAS TO H 2 ANAL VZERS FROM OOT 1 M-69 H G F E D -- 3" DIAMETER C FOR PIGTAILS r--
~
I I I I I I H2 SPAN GAS ZERO GAS I CBY PECO> 100% II:! I CBY PECO! l-~--~--~--~-~~~~!:!..!~~--~--~--~-! 0 1-z <( 0 INCORP. ECR 95-113581 REV. 1 PER WIO C0192650. REVISED AR-2J7 TO READ AR-243. cc.n DESCRIPTION TABLE OF AOOITIONS & CHANGES USE OtLY PRINTS SHlllllNG LATEST DATE MECHANICAL P&.ID GASEOUS RADWASTE-RECOMBINATION <UNIT 21 1------LIMERI--CK-GENERA--TING--S-T_A_TION------1 A PECO ENERGY CO. SCALE DRAllN !GOS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 7116186 SHEET 4 OF I CATEGORY A1 ~}}