I-I
(/)
CX) r-1
- 2:
H G
F E
D c
B A
8 8031-M-78 FROM ILRT UNIT 1 TEST DISCHARGE M-60 CSH.1 H.3l FROM SGTS FILTER A PURGE M-76 CSH.6 G,41 FROM ILRT UNIT 2 TEST DISCHARGE M-60 (SH.2 H,31 FROM SGTS EQUIPMENT ROOM M-78 SH.4 OF
'JDD-139 1' JB0-94
'JDD-239 7
6 C101C~C178A C850-1_B C178AtC178A ~01C@=C178A@C101C TT TAHHH TSHHH TSHH TAHH TSH TAH OB4A 084A 084A OB4A 084A 084A 084A
t C1~01C C101C I
PD I SH 083A ~E
- _J 084A1 590 I
POT i---
H0-07BA<ASl
~OlC
'el I
I I
I I
,-i-1 1:1-_J I I
-~101C XA 086A NO FC 5
4 TO NORTH VENT ST ACK
@01C 088A CSH.3 A.4l NO FC I OAV131 FROM SGTS FILTER 8 PURGE M-76
<SH.6 G,4l FIRE PROTECTION DELUGE SYSTEM 1' JBD-94
~>-~~~~~~~~~~~~~
ISH.2 H,3)
OAS147
~
Vl
<ll l'J I
'!J I
f
<ll I
~
N N
~
t 8
o o
I l
l l'J l'J FS I
~~C178B~~B C178B~C178B ~01C@=C178B ~01COB 5
A I
~
TT
~ TSHHH TSHH TAHH TSH
~
,--,~--0-8~4B~=-~-0-84-=~B~~---0_8_4_B--#=-~0-8-4-B~::~-0-8-4=-B~-----t#-08_4_8 __ "08~4-B--~'-'-:---f.:J-~"---l-~~-.,.-==-#----f~°""Tr-.---I~
C1~01C C101C I
I H0-0788(ASl (SH.10 H,31 PDISH 0838 ~_J I
'!J ssoy I
I ~01c I
~
PDT
,~
~
0838 I
I
~90 Lt--i--
,----i-_J
-~101C XA 0868 I
I C101C OBV124 BATTERY ROOM EXHAUST FANS NC FC FIRE PROTECTION DELUGE SYSTEM M-22 CSH.2 H,3l M-15
<SH.10 E,41 HD-092AIASl FROM UNIT 1 BATTERY ROOMS M-78
<SH.3 G,ll
~
100*
<SH.1 o E,31 H0-092BIASl M-15
<SH.10 E,3>
HD-093A<ASl
~
ISH. l 0 E.3l HD-093BIASl NOTES:
NC FO 100#
- 1. POSH REFERENCE <REFl SENSING POINT JS LOCATED WITH[N 5 INCHES OF POSH 2, STEAM ISOLATION DAMPERS BPD-001-lA, 18, 2A, 2B AND BPD-002-lA, 18 2A, 28 ARE INSTALLED ON EL 200 FT OF THE CONTROL STRUCTURE BUT ARE NON-FUNCTIONAL DUE TO REVISED STEAM PIPE BREAK CONTAINMENT BOUNDARIES. THEIR BLADE POSITION SHALL BE OPEN.
- 3. C02 TRIP CIRCUIT IS ABANDONED IN PLACE.
8 OBS147 NC FD 7
l'J
'Y DRW RETURN AIR FROM:
EMERGENCY SWITCHGEAR ROOMS.
INVERTER ROOMS, CHILLED WATER PUMP MOTORS, AUXILIARY SWITCHGEAR ROOM
<MAKEUP AIR FROM TURBINE ENCLOSURE SUPPLY SYSTEM>
l'J NO FC NC FC DBV131 SGTS ROOM VENTILATION EXHAUST SYSTEM l'J
@---l r------~~~~~1-------l
~~~1 >-----------~
@---l l------~6~~~1-------l ORW
~01C
~-----------<~~~ -- ~
EMERGENCY SWITCHGEAR AND BATTERY ROOMS SUPPLY AIR FAN CABINETS 6
I I
i I
I I
l~OIB I I
_It I
_ I ___ l __ ____j_ J I
I
~
~
~
!D FROM OBV114 TD COOLING COIL i
M-78
)- -
---i TV-C-90-0428 ISH.2 F,6)
I I
FROM OBV116 NC FC I
- 880- -
1
<SH.1 E,ll L
IOBV118l I
~TO CHILLED
--- ----------r-- --7M-90/*wATER PUMP FROM OBV140 ISH.1 G,21 OBP162
- 880- -
t ISH.3 B,31 I
FROM OBV141
_J
- 880--
<SH.3 B.21 5
4 SUPPLY. AIR TO:
EMERGENCY SWITCHGEAR ROOMS INVERTER ROOMS, CW PUMP MOTORS IN, CHILLER EQUIPMENT ROOM BATTERY ROOMS 3
2 SEE NOTE 6, SHEET 2 <TYPI 100*
-1 I
M-15
<SH.10 E,31
<SH,10 E,31 100:11:
M-15 ISH.10 E.2l M-78
<SH.3 G,1)
FROM UNIT 2 BATTERY ROOM AT EL. 239' -0' NORTH
\_ -
_I_ -
STEAM FLOODING DAMPER NO.
BPD 100 5A & B BPD-100-6A & B BPD-I00-7A & 8 8PD-101-SA & B BPD-003-1 A & B BPD-003-4A & B BPD-003-SA & B BPD-003-GA & B 8P0-003-7A & 8 BPD-003-8A & B BPD-009-1 A & B BPD-100-2A & B BPD-100-3A & B BPD-100-4A & 8 8PD-101-1A & B BPD-101 2A & B BPD-101-3A & B BPD-400 2A & B BPD-400-3A & B BPD 400-4A & B BPD-401-2A & B BPD-401-3A & B BPD-401-4A & B BPD-103-lA & B BPD-103-3A & B BP0-103-4A & B BPD 400 SA & B BP0-400-GA & B BPD-400 7A & B BPD-401-5A & B BPD-403-lA & B BP0-403-3A & 8 BPD-403-4A & B LOCATION RECOMBINER ACCESS CONTROL ROOM CHILLER AREA CONTROL ROOM CHILLER AREA CONTROL ROOM CHILLER AREA AUX START-UP SW GR AUX ST ART-UP SW GR ELEV 239' BATTERY ROOM
~
ELEV ROOM ELEV Y ROOM CONT ET RM UP SW GR C
SPREADING ROOM CABLE SPREADING ROOM Iii""""
C ROOM W GR UP SW GR C
SPREADING ROOM C
SPREADING ROOM AUX START-UP SW GR CABLE SPREADING ROOM c
SPREADING ROOM ACCESS CON CHILLER AREA CON CHILLER AREA ACCESS CHILLER AREA CHILLER AREA CHILLER AREA R ACCESS ROOM CHILLER AREA ROOM CHILLER AREA SEE TABLE A FOR OTHER SIGNALS AREA/
ELEVATION B/180' B/200' B/200' B/200' 81217' 8/217' B/239' 8/239' B/239' 81239' 8/269' B/217' B/254' B/254' 81254' B/254' B/217' 8/217' 81254' 8/254' 8/217' 81254' 8/254' B/180' 81200' B/200' 8/180' 81200' B/200' B/200' 8/180' 8/200' B/200' I
100*
M-15 ISH.10 E,2l M-15
<SH.10 E,3l SOLENOID POSH AND HS INDICATING C02 TRIP INSTRUMENT NO.
INSTRUMENT NO.
INSTRUMENT NO.
LIGHT PANEL NO.
SV-78-110A &. B 76 110A &. B OOC729 SV-78-112A & B 78-112A & B OOC728 SV-78-113A & 8 78-113A & B OOC728 SV-78-114A & B 78-114A & B OOC728 SV-78-079A & B 78-079A & B OOC729 SV-78-0SOA & 8 78-0SOA & B OOC729 SV-78-0BIA &. B 78-081A & B OOC729 SV-7B-082A & 8 78-0B2A & B OOC729 SV-78-083A & B 78 083A & 8 OOC729 SV-78-084A & B 78-084A & B OOC729 SV-78-085A & B 7B-085A & B OOC729 SV 78 102A & B 78-102A & B OOC729 SV-78-103A & B 7B-103A & B OOC729 PSH-78-161A & B (NOTE 3l SV-78-104A & 8 78-104A & B OOC729 PSH-78-161A & B <NOTE 31 SV-78-105A & B 7B-105A & B OOC729 PSH-7B-161A & B <NOTE 3l SV-78 106A & B 78 106A & B OOC729 PSH 78 161A & B !NOTE 3l SV-7B-107A & B 78-107A & B OOC729 SV 78-202A & B 78 202A & B OOC729 SV 78 203A & 8 78-203A & B I PSH-78-261 A & B INOTE 31 SV 78 204A & B 78-204A & B PSH-78-261A & B <NOTE 3l SV-78-205A & B 78-205A & B SV-78 206A & B 78-206A & B PSH-78-261A & B (NOTE 3l SV-78-207 A & 8 78-207A & B PSH-78-261A & B INOTE 31 SV-78-11\A & 8 78111A&B OOC729 SV-78-115A & 8 78-115A & B OOC72B SV-78-116A & 8 7B-116A & B OOC728 SV 78 210A & B 78 210A & B OOC729 SV-78-212A & B 78-212A & B OOC728 SV-78-213A & B 78-213A & B OOC728 SV-78-214A & B 78-214A & B OOC728 SV-7B-211A & B 78 211A & B OOC729 SV-78-215A & B 78-215A & B OOC728 SV-78-216A & B 78-216A & B OOC728 I
i--;E-~:;:;L~-;------.,
I
- FOR ADDITIONAL l 1#
INCORP. EC 618876 REV.2 PER WO 4678426.
23 3tJ ABANDONED IN PLACE THE C02 TRIP SYSTEM. ADDED
/(!, NOTE 3. [A-8], [C-1 I. [A&B-2&3J.
CBS I 1 C02 TRIP SIGNAL J ~
~
r- -
_L---------*
I
~I I
I
+
-~729 SV HS B
B POSH DC B
REF-NOTE 1 C729
~1----
DC I
~
l
~-;E;-;A~~-A--:-~-:WALL FOR ADOITJONAL J
- CD2 TRIP SIGNALS I
L---------, I i i
L------------------------------------~
w D >-
z <t D
INCORP. ECR 02-00365 REV.2 PER WO C02D9144.
DELETED TSHL -0996 AND CHANGED TTIC-0998 TD TICSHL-0998. [C,4J.
PARTIAL INCDRP. ECR 02-00365 REV.1 PER WO C0208303.
DELETED TSHL-099A ANO CHANGED TTIC-099A TO TICSHL-099A. [C,4J, INCORP. NCR LG 94-00247 REV. 0.
ADDEO LINE CLASSES JBO-OAS-147 AND JBO-OBS-147.
VAL VE NOS. 0050A AND 0054A WERE INVERTED ALSO VALVES. 00508 ANO 00546 [E,G-6,71.
DESCRIPTION TABLE OF ADDITIONS S. CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID CONTROL ENCLOSURE HVAC H
G F
E D
c I
PSHA~-------------------------1
~~~t~A[1~~~
1 tfl.sil 0~A ~w~ ~trlE2~
L-----------,,--------------------------~
(COMMON) t-~~~~Ll-M-ER-!C-K~GE-N-ER-A-Tl_N_G_S-TA_T_IO_N~~~~,A 3
~n3~
i 2
I I
I 1
FROM L.:~~~:!'-
EXELON NUCLEAR CORP.
SCALE DRAWN
!GOS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 7115/0S APPROVED _,B,,E"'C'"'HT"E"'L'------APPROVED ---------1 SHEET 4 OF 8031-M-78 23 I CATEGORY A 1