ML22278A773

From kanterella
Jump to navigation Jump to search
Rev. 21 to Updated Final Safety Analysis Report, Drawing M-41, Rev. 48, Sheet 1, P&ID-Nuclear Boiler (Unit 1)
ML22278A773
Person / Time
Site: Limerick  
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A773 (1)


Text

1-

r:

V>

H G

F E

D c

B A

8 8031-M-41 SH. 1 OF FROM FEEOWATER SYSTEM M-06

!SH.3 G,Bl FROM FEEOWATER SYSTEM M-06

!SH.3 G,6l 8

UI f§§ 1-Vl uo

<(...!

UI(.)

"'i:i 24' OBD-103

_J L II 24' DBD-104 _J L II UJ O::>

uo

~d

"'i:i C651 C651 DBD,DBB

~

7 24' DBB-103 TEST171 0 '

,. lB 0

24' DBB-104 0

~I'

~

0 io TEST 1:-t*~--~

1009 1008 HV 110

!Hsl03

~

v g

REACTOR io ENCLOSURE TURBINE ENCLOSURE

_J L II (Fo\_J

~

FROM HPCI SYSTEM 0

j;.,

0 TO CONDENSATE FROM RWCU SYSTEM SYSTEM 7

6 FROM RWCU SYSTEM v v 0

0

~

0

fl 0

FROM RCIC SYSTEM FROM SAFEGUARD 24' OBB-103 24' OBB-104 VENT r.i PIPING FILL PUMP 'A'11, HBB-!70 M-52

!SH.2 G,ll 6

5 FROM RWCU SYSTEM M-44

!SH.2 H,7l C803 OJlB I°""

4'06-112 4'

112 v.

1016 LC 4

4' v

i:

i.,,

1017 LC 3

t E39 HBB OBA NOTE TO XR-036-101

-z::ED*

!SH.2 E,1l 1'

t 4' DBA-112

~rPSV

~

TEST I:

M-15

!SH.12 E,41

~

~

~---r HV-1F074A!ASI C651 1'

1036A

~

'Y' CRW C651 c~r---r

~~

<SH.12 C,41

~

C651

[itD

~

0 l!J DRAIN HV-1F074BIASI T

~rSBD~ B~

~ *~

'Y' 1308 ORW FROM SAFEGUARD PIPING FILL PUMP 'B'

~r~..l.~~L.r::-~~~F-~~~~1,.,~rH:B:B:-~11~0:.....L.~~~-<:'.J~~~

M-52

~:..

~'.:j DBA+HBB

"'~

0*

0 t

..-l!J-

~ I ltScr DRAIN 1338 I NOTE 22 HBB-t--DBA 5

ISH.2 E,ll 1056 1057 LC 1' DBA-116 10368 0

CRW 24' DL -105 4' OL -106

~.. _.

HV F011 0--'

.,."'< 0 Ng~E I.

- ;'.:j OLA-105 OLA-107

~

l!J TEST HV F011

~~

35 NO;:LE

~ DLA-106 OLA-108

~u o-'

L:J~

TEST

~:-~*

1' 1'

t-1...... -..1-::i IF083B 1FOB2B LC 4

24* DLA-107 2 'DLA- 08 3

'Y' CRW DRYWELL EQUIPMENT DRAIN TANK M-61 TO STEAM LINE C TO WATER TIGHT JUNCTION BOX PRESSURE VESSEL TO CONTAINMENT WATER SEAL

  • ~--

ISH.1 F,4) 20' DLA-10 24'X20' 12' OLA-108 12' DLA-108 20' OLA-108 12* DLA-108 24'X20' 20'X12' TO WATER TIGHT JUNCTION BOX TE *

  • ~---

'~2~0 ISH.1 F.5>

2 TO NUCLEAR BOILER VESSEL INSTRUMENTATION N7

(

PIPING CONNECTED TO VESSEL HEAD MUST BE FLANGED TO FACILITATE VESSEL HEAD REMOVAL

~

ui:i: UI b~ d N6A REACTOR VESSEL 10S201*

H G

DRYWELL F

E D

c

~:*~*

SUPPRESSION POOL 2

- NOTES REFERENCED ON THIS SHEET ARE LISTED ON SHEET 3 -

INCORP. ECR 08-00106 REV. 0 REMOVED INLET ANO OUTLET FLANGES FROM PSV-1F077.

EJ TJ 8 CG-4l.

w 0

z <(

Cl INCORP. ECR 96-03834 REV. 0 REMOVED L.C. FROM VALVES 04HF038 & 1F039 CF-3l, AND LO. FROM VALVES HV-04HF011A & IF011B CC,0-41.

DESCRIPTION TABLE OF AOOITIONS & CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID NUCLEAR BOILER CICIO

> ~ a..

w:r:a..

""'-' <(

<UNIT 1l t--~~~~L-IM-E-RI-CK~GE_N_E-RA-T-IN_G_S_T_A_TI-ON~~~~-tA EXELON NUCLEAR CORP.

SCALE DRAWN

!GOS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 9/01189 APPROVED BECHTEL APPROVED---------

SHEET OF 6 8031-M-41 48 tF!U" I

CATEGORY A 1

_J