ML22278A706
| ML22278A706 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 09/19/2022 |
| From: | Constellation Energy Generation |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML22278A223 | List:
|
| References | |
| Download: ML22278A706 (1) | |
Text
~
N 0
I-I Vl 0 t-i
- 2 H
G F
E D
c B
A 8
8031-M-70 SH. 2 OF I
7 I
I 6
I 5
4 I
3 2
14' Y:.
Nz PURGE *>-{:J-lll2+'Y,"'2_H.;;B.;;D_-B:..:,6 IN C352 C352 (TI\* - -,.- - (TSH\*
1188 fil
~I~
!i',l l@C352 I 2
~~ t -
w 1
KTD*:
Tl * :
qo*
121
=>~M~-~7o~:>-~~**~E~B~D~-1~2~5~7-',-~{-~-*(:11.. ~4-'~r-.J.~i4~':'":D~-~12:5~~-4~"+e
'~*-]-~61':EB:D1-r':25~-c**K'.:~'-~4i*~~.I..~,-~~
I I
<SH.1 H,51 I
11"4s
- w l
i l05-
, 1150
~l 1 T~:r :
~! ~. ;_-
1* ~:.,~ ;1 1G0Ls~3~:0*
((((] I frEf 121-2 ~~2
- c
~.
~.. _
- c:
1\3' 121-
~
~
C352
..__~_...
~
l
~
~
I
~
I I
C873 I
~
N
%' EBD-125 7.!'
9 '------141\--:iDRAIN Uj r
~NOTE 5 C873 1113
______ [TA<D I
~:3J I
C352 I~*
C352
- ~ ~--fr?f II~*~
L_1 I
~~2:
~
\3T--1
~
1BS371 1114
.~......
- Y2' HBD-86
':'J.
EBO HBO j l Nz PURGE IN 1118 1109 N~~URGE i N~PURGE tffrr I i
,----@C3t2 @-
I Tl TE I
127 125 I
IN I
OUT l ICSSZ
=*
'=
~R=:J ITS *
~-__,POIS >----1 I 69_,- -,-
117 118
~~ I C873 PE~J ~
~r--~
4' EBD-125 1149 L'J DRAIN NOTE 5 Nz PURGE OUT v. " -
1128 HBO EBO Yi y2* HBD-8:1:
- 1186
-1i11 4' EBD-125 1110 I
I I
- l L410-C673I (NOTE l9l 1120 4' EBD-125 1121 C352 dJi !ifJ' (ff! rcc'f
~
--~
124
--~
~2--~
NOTE 5 L'J DRAIN
..... 11221
,, ~
1AS371 1191 N m --
j
- Nz PURGE IN 1125 C352 C873
~---IT*<D C352 C873 I
1
- IT*Hl_+'
~:3J I
I
~~
I i @i 2_@-
~i2@i2 ~
~i 139 -~
r----*
10S371 Cff;J 2
I 139 I
~i2 :
"--t ©-
I I
TI 131 I
- ---C!J
- f2 @-E l
133
""'--~--
L-l10-C673l (NOTE 19l I
I L-f10-C673I tNOTE 19)
~
@.5~
C873 I ___ IT*<D 1 '
C873 I
i
~:3J IT*Hl_l L'J I
C352
~*:3J C352 i <JJ;l -@-- r_,.-~-....,
i @* -@--
@52 __ t ©-
1CS37t
~
2--t
@J-j
- VENT 1FS371 f-@
~--'~
l 1ES371 VENT
'"' ITT 0
N L'J DRAIN NOTE 5 DRAIN "-*1--1 NOTE SL.:
1238 i
@5--
110 -C 673 I- - - - - - - t
...... ~--
<NOTE 19)
I
~
i @}- ""'--~--
i @-
i-------*
1--------*
~--r I
@I C352 I
@I C352 8
@i2 D
w TI
- TI
- I 130 I
136 I
~-------------------*-----------------1 Nz PURGE
.Y2'
'>~1::2_'.._.)--"y,~*
- "6
- 0r-"'6;;_~~:--o-UNIT 1 M-57 CONNECTION (SH.1 H,6) 1181
($H.4 A, 7l I
I I
I I
I L-l10-c573j L
j10-c673I L'J ORA IN NOTE 5 Nz PURGE OUT C873 C352 12*]
(Fr\*
l.'_4"._J
~ ~
(NOTE 191 (NOTE 19)
CHARCOAL ADSORBERS C352 I
C352
~
~--l.--- * ----i----1--0§' M-69
)-
TD FR-69-115
~
l CSH.1 E,8)
I I C582 FT 150 FE 150
- Nz PURGE OUT ro '
D fl'
!~
m w
I w
m m w
~
D z Y2' 1182 D
m w
N ODP TEST TAP Y2" HBD-86 r;-i NOTE 7 1135 I
L'J DRAIN NOTE 5 RADWASTE ENCLOSURE VENTILATION SYSTEM C305 C305
'f' I
I I
I I
l_
c..T 2
C305
"'o--/
G/
' -1
-i ~_.. - - - ~---@ al\)
TO L~1Hi
~
1Y2" I II
~~*
1Y2*
1Y2'HBD-163 4'HB0-163
_ @--* H:J-l,1-f.:f
- -:--T-~_!21.,!!!;~:2.,_L_~~Mi3-6'!::1 =>>-
1111 1146 2
OFFGAS ENCLOSURE FLOOR DRAIN SUMP OOPSOO 7
Pl 1 Y2' x 2' 0
~
073
~
I I
<SH.
H,IJ 6
I
> M-l5 CSH.36 H, 1) 5
~~i
~--@)
I f--#--r,,~~: NO TE 1 L'J VALVE SEAL AIR HEADER C873 C352 ~
~-1--
4 I
4" x 6' OUTLET HEPA FILTER 10F371
- OOP TEST TAP Y2" HB0-86
}'2~
_,,,%' N PURGE 2
1180 -
IN C5*82
- 4* X 6*
~*
. I 4' PDIS)----&.~~~~~~~...L~~~j--~~~~~~~~r----f 149 1138 3
I I
L'J DRAIN NOTE 5 2
I NOTES:
- 1.
SEAL AIR SUPPLIED TO STEMS OF ALL PROCESS AND DRAIN PLUG VALVES. 1,4* FNPT.
- 2.
AIR VENT IS FLOAT OPERATED.
- 3.
DELETED.
- 4.
RADWASTE PIPING IS LIMITED TO THOSE LINES DESIGNATED DBD ANO EBO.
- 5. VENTS AND DRAINS LOCATED ON CHARCOAL ADSORBER TANKS AND CONNECTING PIPING WILL BE SEAL WELDED CLOSED FOLLOWING HYDRO TEST AND PRIOR TO LEAK TESTING IN ACCORDANCE WITH ANSl/ANS-55.4-1979.
- 6. PACKLESS DESIGN.
- 1.
3' SCHEDULE 160, 12 PIPE DIAMETERS IN LENGTH.
- 8. SPOOL PIECE WILL BE LEFT IN PLACE DURING OPERATION, OPEN PORTION OF SPECTACLE BLIND FLANGE IS INST AL LED DURING NORMAL OPERATION.
- 9.
GLYCOL MUST BE TESTED FOR pH PERIODICALLY AND THE INHIBITOR RENEWED.
- 11. LINES 1' HCD-125 AND%' HCD-126 SHOULD BE SCHEDULE 80 FOR HYDROGEN DETONATION CONSIDERATIONS.
- 12. HOSE CONNECTION IS TO BE LOCATED CLOSE TO UNITS 1 AND 2 GLYCOL SKIDS. VALVE 0005 IS TO BE LOCATED BY THE HOSE CONNECTION.
- 13. VALVE CV-174 IS TO FAIL TO CHEMICAL WASTE TANK ON LOSS OF POWER, FAIL-AS-IS ON LOSS OF AIR. DISCHARGE TO CHEMICAL WASTE IS TO BE LOCATED C! HIGHEST VALVE DISCHARGE POINT.
- 14. GLYCOL SYSTEM VENTS AND DRAINS MUST DISCHARGE WITHIN CURBED BOUNDARY BENEATH GLYCOL EQUIPMENT.
15, DELETED.
- 16. DELETED.
- 17. 6" EB0-125 SHALL BE HEAT TRACED UPSTREAM OF ME-117 BUT NO CLOSER THAN 10 FT MINIMUM DOWNSTREAM OF TE-116.
SELF LIMITING HEAT TRACING RATED AT 2500 WATTS SHALL MAINTAIN GAS TEMPERATURE AT 60 9 F MINIMUM.
- 18. VALVES 1147 AND 2147 ARE OPERATED IN SIMULTANEOUS ACTION THAT IS CAUSED BY A U-JOINT REACH ROD MECHANISM.
- 19. POINT CONNECTIONS SHOWN ON DRAWING M-207-00274 SH.2.
r INCORP. EC 629380 RE\1.0.
34 z.3 ADDED ANALOG COMPUTER INPUT A3015 AND A3016.
[/ [G, 7] AND [D-E.51.
}' INCORP. EC 423037 REV.6 PER WO 4180185. DELETED 33 ~ XY-036-124. XR-036-101 & 102. Xl-036-101 & 102.
/11 ADDED 10-C673 ANO NOTE 19. [VARIOUS].
INCORP. ECR 02-00558 REV. I PER WO C0205707. DELETED 32 {o. TR-70-124 FROM 1A THRU G-S371. ADDED XY-036-124, XR-
,;6:; 036-101.102 & XI-036-101.102 TO 1A THRU G-S371.
[E-G,2-6J EJW JC~IJMK EJ JC\IMSl H
G F
E D
c w
0 z
<(
0 DESCRIPTION 0
0 0
>::..::: o..-
w IQ.
TABLE OF ADDITIONS & CHANCES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL I
P&ID GASEOUS RAOWASTE AMBIENT CHARCOAL TREATMENT
<UNIT 1 AND COMMON>
LIMERICK GENERA TING STATION EXELON NUCLEAR CORP,
°' u
<(
SCALE I
DRAWN I
IGDS I CHECKED I INSPECTED I APPROVED I DATE NONE I BECHTEL I BECHTEL I BECHTEL I BECHTEL I BECH I BECH IOB/15/8 APPROVED BECHTEL APPROVED SHEET 2 OF I 8031-M-70 Ill 34 I CA TE GORY A 1 A