H G
F E
D c
B A
8 8031-M-87 SH. 1 DEMIN WATER2' JCD-1l3 M-18 lSH.2 A.8>
1055 EL 393' ORYWELL CHILLED WATER SYSTEM HEAD TANK IOT157 l LOCATED ABOVE HIGHEST POINT IN 1lE PIPING SYSTEM!
- ' JBD-181 :1:. RBD-181 1-:::....:::::..:.::.:..........,_:::..:;:::;..:.:::.;_:JyENT 8
12' 1048A NO 10488 NO 1060 l!.J DRAIN 1BP161 CHILLED WATER CIRCULATION PUMPS 7
2" 1052 6
BECHTEL VENDOR
~*JBD-334 TO 013-1130 DRW
- w iii 0:
.... Q i5 ~
1)!,* JBD-309 N
- 0.
1050 CHEMICAL FEED TANK 10T152 1051 JBO JBO 309 310 REACTOR ENCLOSURE
_J LJ L TURBINE ENCLOSURE 111 I RAOWASTE ENCLOSURE HVAC 5
~
(SH.3 C.Bl
~
lSH.3 C.Bl
~
lSH.1 H,6>
M-79 lSH.3 C.8l
~
lSH.3 0,8)
~
lSH.1 H,6>
l!.J DRAIN 4
RADWASTE SERVICE AND CONTROL AREA FAN CABINET
>V
,y
"' g 0
2" 0023A
<C.,
0 0
l!.J DRAIN
- v;v;Y;;.
>V u...
RADWASTE ENCLOSURE COOLING COILS
- "JOO *"
- JVENT 0020
<C 8 0
0 NOTE 1 AP 3" JBD-52 3
RADWASTE ENCLOSURE SUPPLY AIR COOLING COIL ASSEMBLY
~
VENT E *" *" JBD-52 0016
- ' JBD-53 *"
r--~-..t-:JVENT 3*
.... g l!.J DRAIN
- OAE374, OBE374 OCE374 3* JBD-53 0
0 l!.J DRAIN 0024 1'JBO 1*
DRAINE...;_=........,
- " VENT 1-w-;;;;.;.;...:i 1144 3"JBD-6"JBD-52 1146 0018 F8 4*
h \§)
2 6" JBD-53 C681 11r1
~126 E-1 VENTE *"RBD-1:1: *"JB0-189 1142 E 1*RBD-1~1*JBD-181 1140 C681 I 1:21 H
G 8'JBD-190
__________________________________________ J RBD JBO VENT@'RBD-1::=-i; *"JBD-189 1181
~-1
'Y NW 7
I 1
12" JBD-188 12' JBD-188
<D
<D Q
~
- 0.
l!.J 12'JB0-188 COMPRESSOR MOTOR COMPRESSOR r
PUMPOITT
-O~E~-1 UNIT IAK115*
1AEl95*
I c:t\A A~
!';'\
'-.__/ ~
_V_ 'CJ I g
-s ~A~~:i-I
~
1' *-
- I o~AP~~*
J
/"
~ L C128A
~ ----
~t---1--i-~~~~~~~~-r--l:A
- 0.
VENT TO EXTERIOR OF ENCLOSURE 1'
ri"1 1'
ri"1 1*
l!.J
~*RBD-181 WATER CHILLER 1AK111 I
'---------------------__J 6
5 12' JBD-181 12" 189
~*----.,
~*
C126 C681
--@-~ l1;:!Al
-~:
- f--#--1~. ~
I I
@-~
C681 HV-102A!A/Sl1-11 I
~
1--;---1 : ~~
11J28l=.R I I I
I I I
I I
=i----~*1~
I I
I I
~--,-:J..
I TO &. FROM
~
,....a~------~-.
~~:~~
1 _GJ y CONDENSER I
,_. I ::L _1 _J 1
I COMPRESSOR I [------1,:J co:OR I
I I
,---------~ PUMP OITT I
I OIL HEATER I UNIT 1BK115
- I 1BE195*
I 1
11 ~TE c:t\A_A
____ J l~~_V_'C]
~-s
""le~~
I ~
Oll-
¢
~ c~aa
~ l_:_,:: ____ _
~
1*
~t----1--i-~~~~~~~~"""T_,IX I
I I
I 1*
l!.J 26 s
1 I
I I
I
.. *_RB_o_-_18_1-t-:J VENT I
I
_I 4
VENT TO EXTERIOR OF ENCLOSURE ri"1 1'
ri"1 1'
§q
~ -
a::
Q O'i WATER CHILLER 1BK111 I
'---------------------__J 3
2
- NOTES REFERENCED ON THIS SHEET ARE LISTED ON SHEET 3 -
PARTIAL !NCORP. OF ECR 1D-001T1 REV.4 PER W.O.
C0245821. ADDED TE-184R05,6,7,8, &. 9 TO WATER CHILLER 3 1B-K111. CB-ll, 2-31 INCDRP. ECR 06-00161 REV.O.
6 REPLACED VALVES 1116A&.B lllTH SS BALL AND 1lE o PIPING lllTH SS. £C-3&.Sl INCDRP. AR A1454467 E29 lREF. !R 642115 A021.
ADDED CONTINUATIONS TO M-13 SHT.1 FROM 10-T151 ANO 10-T152 [G-6&1l DESCRIPTION TABLE OF ADOffiONS &. CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID DRYWELL CHILLED WATER D
c
<UNIT 1 AND COMMON>
1-----~UM~ER-ICK~GENER~~A-TING~-ST_A_T_IO_N~~~--1A EXELON NUCLEAR CORP.
SCALE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH SHEET 1 OF I CATEGORY A1