{{#Wiki_filter:1-8 8031-M-26 H G F E D c B <D ,..: A
- i:
!!) <D N 8 I 1 6 I SH. 61 DESCRIPTION DETAIL SAMPLE POINT ELEMENTS LOCAL RACK PAR tr.METERS RE/SE NOATtiSTACK EFFLUOU MONITOR *
- WIOE4lAHGE
.6.CClDeHT MONITOR** SE26-076 A.1.0WASTE EOUIPWENT SE26-0 16-1AND ROQ'1S VENT. EXHAUST* 016-4 HIRU 016*9 R.lOflASTEENClOSURE SE26--0N008 EXH*UST
- CONTROL ROOM NORMAL RE26--007A-1, Z FRESH AlA: SUl'f>lY *
- RE26-<l0i8-l, 2 REZ6-<l01C-1,2 RE.2&-<lOl0-1. 2 CONTROL ROON EMERGENCY Rt26-0MC-1, 2 FRESH AlFt SllPPLY ~
- RE26-0680-1,l HOT MAINTENl\ffCE**
SlfOI' VOIT. EXHAUST RAOll'ASTE DlSCHAACE* S£6J-009 RllR SERVICE. WATER Ji!; 5£12-022..t. S£1'Z-022B C.E.SUP?t..1£0 SYSTEM TH£R£'SLJST£D ARE
- G...&.. SlPPUEO SYSTEM tN-LlNE SAMPUMG RAOIATIONEl.EME'.NTS.
THE OFF-LINE R£'S ARE NOT LISTED. SEWAGE TREATfJENT Rf:- OZG- 088 ~ I. LOCATIOliS OF VElffllATTOH ir.HO OAS PROCESS RADIATION MONITORING INSTR!Jt,OITUION ARE SHOWN HERL LOCAT.!OHS Dr LlOU!I) PROCESS RAOl.t.TION loQN!TORtNG INSTRUMENTATION ARE SHOWN IN P&IO IHO.l~, ll AND 63.
- 2.
EOOlPMEN'I' ANO OUCTIMC OETAll.S ARE NOT COMPLETELY S>>OWN FOR rnrs ARtA. ONl.Y COMPONENTS WITH RAOJATTON ldONlTORINC OR SAMPLl>>C Off MAJOR VALVINC.I.RE Sl<OWN..
- 3.
OU£TED. CSE£ SHEET 3.1 -4. AA£A SUPPLY F.t.NS AR6 NOT SMOWN. SEE CONTROL O!AGIUMS FO!'IOETAlLS.
- s.
GAS n_ows INOJC:A TEO ARE BASED ON MAXIMUl.I RA TED FAN CAPACITY. 6.. RECIRCULATION SYSTEM, SOTS.l.tlllN STEAM TUNNEL.REACTOR EHCLOSURE. REFUELl NC FLOOR. fJID CONTROL ENCLOSURE \'ENTILATION ARE NUCLEAR SAFETY CFIAOE WlTH tNSTRUMBfTATION 01.JALlflED Til IEEE 279, 323,ANll 344.
- 7.
OELETED. tsa'. HET 3J
- 8.
TIE GE M?L Nl.MBER FOR TilESE SYSTEMS lS 012.
- 9.
TIE. NORTII STACK SAIE'LE U NES ARE AS FOLLOWSi NOZZlENO.TO~ ~ t.llN.BENORAO(US OOSl70 OOSITO SE26-076 0.C.,BS595 1' SST X.06S' WALL OIS9°" 1'SST X.065'WALL 015900 Y:' SST X.065' WAlL TI£ TUBINC LEl<<lnlS SHALL BE WELDED OR CONNECTED WITH FITTINGS DF St.IOOTH TRANSITION TO,t.VOlO fl.OW OISTUflS*NCES ANO liCCUMl..LATION Df RAlHO* c nVE PARTICUU.T£S. NO ELBD\llSPERMITTEO.THEruaESHALLSLOPESOTH.t.TTHE CONDENSATE WILL RUH TO DRAIN TEE.
- 10.
EXCEPT AS NOTED, ALL GAS ANO HVAC SAMPLE LlJES SHltlL 8£ l' OUMETER X.oGS' W.l.LL TI-IIOtHESS S(.t..... ESS SS TUBIMO. IBE TIJBJMG Ml!'flM'..JM !\Et() RAOflJS SHALL 8£ 12' 1'0R 1' TU61NG AICO 6' FOR *.'TUBING. THE TUSING SHALL St SI.OPED TO FAClUTTE Tl£ DRAINING OF CONOENSATE. PANEL ORAIN LIKS WITH K.*o.o.x..OSS' WAlL S.S. TUBING W.TERIAL SA-J!:tl*TP-J04l SHAU & ROUTED TO 1HE ORAJN I 7 MONITORS:O er SR SAMPLE GRID EQUIPMENT 005170 (SAMfLE Al 0AS5!15 Ro\OlAT!ON.FLOW OOS 170 lSAM?LE Al 06$595 R.W!ATION. FLOW 005110 ISAMf'LE 61 01 $908 RAO!ATION. FLOW 025909 SJIZS-016 RWIATION RAOIA110N RAOIATION RADIATION RADIATION RADIATION 11.t.OU.TIQN,FLOW SR!2--0221 0 ASS78 SR12-0228 REACIOUTAtll ALARM ARE AVAILABLE TO OPERATOR ON RMMS FOR THOSE PARAMETERS BEING t.IONITOREO. RADIATION UOU!O SAMPLE CONNECTIONS, VAl..VES, ltHD LINES SHALL BE !' CARBON STEa PIPIHC, <SEE 0£1.lil Kl. ONE SET DI' Ro\lllATIDN AHi> FLOW Al.ARMS IS SMARt:O BY 105182 AND 205 182 lCOHTAtN.IENT LEAl OETECTOR)(lH 0QC82.(. THE CORRESf>ONOING ALARM TAG NUMBERS AR£ OF TKE: FORM XXXX-2:6-090. ANSI N\3,1 SECTION -i ANO APf>ENOICES A. B & C SHOULD BE FOLLOWED FOR SA'4'U UIES IN SYSTEMS WHERE PARTICULATE SAMPLING lS REQUIRED. H. 0Et.ETE0,(S£ESNEET 3)
- 15. EOUJPt.IENT NUISERS FOR STAO: SAMPLE PUMPS. OOP59~
FOR THE NOOTK STAO\ ANO UP702, 16P702, 2Af'T02' ANO 2BP702 FOR THE SOUTilSTACK.
- 16.
ntE.ltE IS DNLY ONE F.i\K. ANNUNCIATOR WINOOW fCOMMONIFOR ALL RHR SERVICE WATER MONHORS WEUJL IO.
- 17.
HEAT TRAClNG IS REQUIRED OH Tl£ F'OLl.OW!HG APPUCATIONSc <A>SE-2'6-076 ANO 005170 tS.t.MPLE WTO 0059011 (DETAIL Gl (6)00$170 tS.AMPLE A>TQ OAS595/0BSS95 WETAIL !'°)
- 16.
OELETEO. <SffSHEEf 3) 19, WSTALL SlPHtm BREAKERS ON ALLS-TRAPS. 2:Q. THlS E.LECTfflCAl. CONNECTION IS lNCLLDEO TD PROVIDE 120 VAC FOR HEA! TRAClNG Of SM.f'LE INFllENT TUBING M£N REOUlllEO 8Y SAMPLE MOlSTURE CONTENT. SAMPLE RETlJRN U NES ARENOT TO SEfEAT TRACEl).NO INSTRUt.IEJO' IN nus MOUP REQUIRES MEAT TRACINC AT THJS T!IAE (f:IEFERS TO OETAil B ONl.Yl..
- 21.
TlfE Fl3lLD'IUN:: SPECIAL SYM&OLS ARE OEF!NEO F~ USE ON P&lD Ll-2:6 Olt.Y. AS FOLLOWS.. fl,) "fl:'!" 0£$!GNATES LOCltl.LY MOl.IUEO MICROPRDCESSOR. <Bl "RIX'DESJGNATES MICROPROCESSOR CONTROL/JNOICATOR UNIT. (Cl 8 ~!i~1f~~~;~~Z:~E~i~rcAL ACCESS TO MICROPROCESSOR OATA, 6 I 5 PROCESS RAOU TlDN MONITORING EQUIPMENT RATEMETER OR PANEL RADIATION RECORDERS READOUT / CONTROL NIJMSER RECORDER
- R!X26-Q76 Rft26-076 AISH26-0K613 RR;a6"'(1RGQ9 RJSH26-0K615 Rlt26-{IA609 RIX26-0071i OOC69!
Rl)(26-00T8 OOCl>91 RIX26-00TC OOCl>91 Rl:ir26-001T) RJX16-0GflC OOC691 RIX26-(;6l!O AA63-(IR()()I R1SHl2-0K6 19A IOC606 RRl2-0R615.A RISMl2-0l.6198 IOC:633 Rfl12*0R6!56 ALL RISH'S ARE SUf>PUO 6Y G.E.. ANO fJ.L RJX'S ARE SUPPt.rEOBYG.A ** RM-02:6-096 <ALARM ONLYl Rfl-026*088 <:2.
- 0£.NUTES EQUIPMENT SUPPl..lEO BY GENERAL ELECTRIC COMPAllV.
- 23. J.LAAt.I AAKl lS F~ Tf.IERA0WAS1E 0JSCW.RC£ SYSTEM ONLY.
PEN * !, 2.3 \NQTE35l
- 24.
St<IOS TO BE SEPARATED AS SllOW>I lN LAYOUT ORAWINC M-8~. TUSING CONNECTIONS BEt'llEEN St<IOS TU 8E SUl>PLJEO 9Y BECJITEL,IN ACCORDANCE Wl7M NOTE 9. ?5. EQUIPMENT SUPPLIED AltO INSTALLED BY BECKTEL ON G.LRA.CK,
- 26. DELETED. !SE£SHE.£T3l 2'T.OELnEO.ISE£SHEET3l
- 28. OELETEO.!SEE SHE.ET 31
- 29.
THE CO~SSION COIJPLl.NG Sl(JU.O BE.t.T LEAST 10' UPSTREAM FROM THE ISOKINETIC Fl.OW OIVlOEfl. TH£ R[t.('IVASLE SPOOL OR DIVIDER WILL ENA8L£ PURGING OF SAMPLE NOZZLES ltNb GRAB SAMPLING. USE Cl.£AN FUXJBI..£ llOSE FOR PIJRGINC.
- 30. DELETEO.!SEE SHEET 3l TH£lNSTALLATI!JNSOF TI!£NCIRTHSTACK S.u.f>LE8YPASS LINE.ITS ASSOCIATED fflSTRUMEN!Al!OH,ANO FX*Z6*014-Z ARE NOT REQUIRED FOR UNIT I OPERATION. Fl! 0l~-2 JS TO BE PUT IN Pt.ACE OF THE SPOOL All) CONNECTED TO TIE 8YPASS LINE FOR TW(HJNIT OPERAT!OK.
- 32. TUBIHG RUJ.IS FOR SAMPLE PDJHTS SX-26-041, SX-26-042:A, sx~26*0Ull, SX-Z6-<M!IA ANO SX 0~lB ARE %' 0.0.X
,065"WALl SS TUSING. J3. FOR ALL NONSEISMIC CATEGORY I VENTS.DRAINS AMO TEST COtlNECTIDNS, OESJGN, FA6RlC4TIOlf, MATERIAL PROCURDIENT, ERECTION AND TESTiNG FOR ALL PIPINC OOtNSTREAM OF THE lltST IS!)l.ATJON V.C.LVE, MAY & IN ACCORDANCE 'lflnlOEStGJI CLASSO. 3-4. OELE'TEO
- 35.
THESE RECOROEJIS 00 ~T USE PENS. 5 PANEL
- OOC624 OOC62-4 0AC304 OCC667 OBC667 4
I FLOW RECORDERS RECORDER
- PEN
- PANEL
- FA2fr-076tucJISEC>
1,2.J ltjQT£351 I 3 2 ALARM PANELS ELECTRICAL INSTRUMENT l)JVJS!l)N RADIATION FUlW ASSIGNMENTS NUMBERS OOCll2< 015A,074 OOC82< Ol!lB.074 "°" <>=* 007' OOC82-4 n 0018 Ill 007C 0070 HI* 0680 0AC30.( l OAC867 02" OBC86l OAC867 "°"'
- NONE NIA :NOT APPLICABLE TO Tl£ SYSTEM 3
2 I SAMPLE LOCATTOHS REMARKS H REFERENCE M-2ti SK.4 (G-H.61 M-26 Stt.4 (G-tf,Sl M-26 SH. 4 <G-tl, 6) Ol'F-t.lNEGAS Y...79 SH.2 CH,ll M-7BSH.2 !A,Bl M-lB SM.21C,&1 M-l8SH.2(A,8l 1.4-l8SM.2 !C,&I M~78 SM.1 (F.41 M-18 SH.I <F,4l M-62 SH.1 fH,61 M*63 SM.2 CD.3l M-12 !F,TI M-12 CG.2> G-OSJ~. SIU M-0026, Stl.5 OFF-l!NE HVAC lN-LlNEHVAC tN-UNE MV...C G lN-LlN£HVAC IN-l!N£MVA.C IN-llN[MVAC lN-LfflE HVAC OFF-llNE HVAC OFF-UNE UOUlO OFF-U NELIOUID F E D c Vff<?*EOUlP. TA6LE AOOEO D r H DER COLUMN FOR RR26-076. ~ ~ DESCRIPTION ~ ~ ~ - TABLE OF AOOITID!rtS l CHANGi::s USE ONLY PRtNTS SHOWING LATEST CATE MECHANICAL I P&.10 PLANT PROCESS RADIA T!ON MONITORING tCOMMONl f-~~~-LI-MER~ IC_K_ GEH~ER-AT-I-NG_S_T-AT_IO_N~~~-IA PECO ENERGY CO. SCALE OOAWN lGOS CME.CK£!> lHS!'ECTED APPROVED ~NE e.ECHTEl BECKTEL BECHT(L 8£CHTEL BECH atCll 212511 * = "!t!!El OF 8031-M-26 !Kl 29 i I CATEGORY A1 d}}