en 1-
- c l/)
0 N
I H
G F
E D
c B
A 8
8031-M-20 8
SH. 9 OF I
7 I
6
~~
~
JI*
~
2162~@;0
~
225A I
j L I
5
~-©14A r -
.:....f:'E~;!f,,......,
I,~---
2201A
~
~: : 2206A
~C514A
- '7~
_,7 I
I 2141A)~.~ ~
- "
- ", ;.2140A I
I PSL 225A I
' I
- ' '7
~. :::. 2144A I
1 _BS }
I
.---.:.----'y,~*~=**i:J--+-1~
2139A' ~ ~
~' ~2138A 2145AL :::..;::.'!
JI* I
@1
,--;P--'---120~5~5A-,--...i...--11@1t--....&.-----,--r--------I_~
I 2A1F575 I
DIESEL ENGINE 2AG501 I
I I
I" I
~:
I I
I I
I I
2AP537 ENGINE DRIVEN FUEL PUMP I
I ' l I
I
~14A I
____r;;;yp[\_
I I~ I l_
1 __ ~
I r--i~
I r@F-* __ I 2209*, '. "1:
"1:: :z2oaA I 2137A7*
"*'7 t- ---- ---- __ _j
~
~ 2136A DIRTY FUEL DRAIN TANK 2AT531
~ 2057A LG 22~A LSH 225A LAH LSH LSH LSH C514A I,: -
~
~
128A-I 118'-2 18i-J DRIP PAN v.i*
I
- ;.-g-* ;.,
,_y,~* ;:::::i-'"-iE': l--+-1~:1-' -+-1:..-a----ij' ~
Jl:J......L---'-' 4_3_*.J:_c_;,:~:~1-"'--':.. :_'_'4_'_'_;;,,__T'"_,: 2054A DIESEL-GENERATOR 2AG501 11 I
2058A-1 t I w ow L;::;-----t....,__
2058A-2 -'*
ow j
l l I
~
0 m I
2" I
,7.
- *'7 2135A * ;>.~
~. 2'2134A
~
I"~
1 2AP538 DC MOTOR DRIVEN FUEL PUMP 2A2F575 DUPLEX FILTERS 20ssA-3 t ow VENDOR SUPPLIED PACKAGE(SEE NOTE 17l I
~---------------------------------------------------------------------------------------------------------------------------------------------------------------_;
1" HB0-81.:I PSV 221
- 1........
'4::.l
'--,--I--I--,-.-HR-0--8-1_3 _ _,_~~-----,
_J L II t Y2" HBD-8 I 3 I
~}4A
~u~
~ T
- T 2'
[-
1' HB0-813 2'
NOTE 11
[-
/Ys\
223A-2 1Y2"
~
- I *
~
'X.
2159A < /
2158A LO
'v LO NOTE ! 1 fYS\
223A-1 1Y2*
Y 1Y2*
. I.
2161A <'J<
2160A LO V
LO 7
w D w '
0 m I
2' HBD-455 DIESEL-GENERATOR DAY TANK 2AT528
- L!J 2051A DRAIN CONNECTION I
SUMP GRAVITY R£1URN I
I I
orESEL-GENERATOR ENCLOSURE
_J L J'
TO DIESEL I
2" HBD-'165 1-~~---~~~--1 GENERATOR 2CG501 j TO DIESEL I
GENERATOR 2BG501 \!----------!
?.' HBD-465
- 2100A TO DIESEL 11-_....;;.z'_H;;;B.;:.D_-4_6-'"5--__,\
GENERATOR 2DG501 j
\
2'HB0-4G5 2080A LC I
TO DIESEL GENERATOR 2CG501 ll---------t_PUl-1P DISCHARGE INTERTIE L[NE I
TO D!ESEL I
2' HB0-'165 GENERAlOR 2BG5011-,---------1 TO DIESEL I
GENERATOR 2DG501 !,_ _______ _,
2' HBD-465 GRAVJT'f RETURN IN1ERT 1£ LINE 6
FUEL OIL & TRANSFER SYSTEM
<"A" DIESEL SHOWN TYPICAL FOR B,C, & Dl 5
I I
4 I
3 4
I 3
2' HB0-465 CBYPASSJ I
2 rn 2
I NOTES:
- 1. THE D!ESE:L-GENERATOR FUEL OIL SUPPLY SYSTEM [S SEIMS!C CLASS t EXTENDING FROM THE OTF.SEL OIL STORAGE TANKS TO THE DIESEL ENGINE.
2.VALVE 0g2-2402D WAS REPLACED WITH A SS ANGLE VAL VE AUD A SECTION OF THE OOWNSTRF.AM TUBING WAS REPLACED WITH SS FLEXIBLE HOSE. APPLICABLE ONLY TO EOG 024~ REFER TO EC 629553.
- 3. DIESEL EXl-IAUST PIPING SHALL BE SEAMWELDEO ASTM A-155 GR C-55 CLASS 2,(FJRE BOX OUAL[TYl,STD WALL.SE[SMIC CLASS 1,AND SHALL BE BUILT PEA SPECIFICATION 8031-P-313.
4, !'AND 1~1z'HBD-813 AND l'HB0-814 PIPING IS TO BE PROCURED ro ASME SECTION llI CLASS 3 WITHOUT THE N-STAMP.
- 5. NON-0 DRAIN AND VENT LINES AND CAPPED ENOS EXTENDING FROf-1 SEISMIC CATEGORY I PIPING ARE SEIMS!C CATEGORY lIA DOWNSTR£AM OF THE LAST ISOLATION VALVE.
- 6. DELETED
- 7. LOCATE DRAIN VALVE AS CLOSE AS POSSIBLE TO DRAIN POT. DRAIN CONNECTION JS LOCATED IN A SILENCER SHELL LOW POINT, 8.FOR ALL NON-SEISMIC CATEGORY I CAPPED VENTS, DRAINS ANO TEST CDHNECTIONS: DESIGN. FABRICATION, MATERIAL PROCUREMENT. ERECl!ON AND TESTING FOR ALL PIPING DOWNSTREAM OF THE LAST ISOLATION VALVE MAY BE IN ACCORDANCE WITH DESIGN CLASS 0.
- 9. DELElED
- 10. HEAT TRAC1NG INSTALLED FROM ELBOW TO ROOF-.
HEAT TP..ACIMG JS NOT 0-LfSTEO.
- 11. THE SCREEN ELEMENT HAS BEEN REMOVED FROM STRAINER.
12.ASME BOUNDARIES SHOWN ON THIS DRAWING ARE FOR REFERENCE ONL Y,SEE ASME PIPING SPECIFICATIONS FOR A001TIONAL INFORMATION.
- 13. NON-ASME PIPING ANO EQUIPMENT WITHIN THE SKID OUTLINE ARE DESIGNED TO MANUFACTURERS STANDARDS lCOL Tl, 1'1. EQUIPMEJ~T AND COMPONENTS ARE DESIGNED TD MANUfACTURERS STANDAHDS (COLT},
- 15. EfJUIPMENT IS DESIGNED TO ASME VIII
- 16. EQUIPMENT IS DESIGNED TD ASl-1E IV.
17.ALL COMPONENTS WITHIN THE BOUNDS OF OF THIS VENDOR PACKAGE ARE IN SYSTEW1 92.
- 18. PIPING PROCUREMENT, TESTING, REPAIR MAY BE IN ACCORDANCE WITH REQUIREMENTS OF ANSI 631.1 PER NCR 93-00214.
19.ECR 02-00079 PRE-APPROVED THE REPLACEMENT OF REMOTE MOUNTED DUPLEX TEMPERA fURE INO[CA TORS WI TH A S[NGLE REMO rE MOUNTED TEMPERtTURE INDICATOR AND A SINGLE LOCAL MOUNTED TEMPERATURE I:-.!DICAfOR. REFER TO CRL FOR DETERMINATION OF 'l\'HICH DEVICES ARE INSTALLED. INSTALLED DEVICES W[LL HAVE AN 'F' OR "C' IN TH[ STATUS FJELD.
- 20. TLJBING, '.%" x 0.035' WALL, S.S., PER ECR 15-00213.
tili INCORP. EC 5zq5s3 REY.0 PER W/O 4q74173-0g.
20 1 ADDEO NOTE 2.
IC [H,1-2I.
1Y
!NCORP. EC s24g5s REV. 1.
l"tr2} DELETED NOTE 21.
'18 CE, 1 J.
i.J;'.
[NCORP.EC 624958 REV.0 PER WIO 4727390.
18.:y AEDED NOTE 21.
"18 [::, 1 l,
!lJ.::: iNCORP. ECR 15-00213 REY. 0 PER \110 C0256737.
17 18 ADDED NOTE 20.
f.-1 [£, 1 I.
EJW RC>
IRS Kii RC., 8Tll EJW JCW l'B'll 000 H
G F
E D
c w
0 f---
z
<(
0 DESCRIPTION
> ~ D..-
w I 0..
0:: (_} <(
TABLE OF ADDITIONS & CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL I
P & I DIAGRAM FUEL & DIESEL OIL STORAGE & TRANSFER CFUEL OIL & TRANSFER SYSTEM UNIT 2>
t--~~~~~~~~~~~~~~~~~---1A LIMERICK GENERATING STATION EXELON NUCLEAR CORP.
SCALE I DRAWN J
IGDS I CHECKED I INSPECTED I APPROVED I DATE NONE I BECHTEL I BECHTEL I BECHTEL I BECHTEL IBECH IBECH J12n11a9 APPROVED BECHTEL APPROVED ---------1 SHEET 9 OF I 8031-M-20 l~I 20 I
st!LEt I CATEGORY Al