H G
F E
D c
B A
8 8031-M-28 SH. 1 OF ALTERNATOR CASING 10G102
<NOTE 4)
L!J 1' ALARM TEST CONNECTION 7
6 6' JBD-346 5
EV--,
EV-*
I GENERATOR GAS MONITOR 10S191 NOTE 7 VENT 13
~ ! "
~
g
__j l___B!>oF
- OFFGAS TURBINE
~ ENCLOSURE ENCLOSURE L!J DRAIN PSV 130
)'2* HCD-132 EXISTING ENO SHIELD MANWAY COVER NOTE 15 [:-*t---;
1191 NOTE 16 [:--lllll---l 1192 GAS ANALYZER Cl\JREJ11JOR r.l 4
2"*
1063 N
0 L!J
~1'1111J1111001111-1111~
.. 6..
~1*0-*0~... -c.:i-.._-+11111111111111111 1111*J 1111B 1111D-111131111451111111111111111.......
1111111111111111_Jiiillll*L-...... llll(J1**"""'~ti--i~""'P-C::.."""......... ~
......... -<Jo-9""'*1*1111*1111111111111111"""'1~11111111-t NOTE 3 t I VENT 1" CBD-104 L------
L!J BECHTEL APCI r-----
- "' e I
~------
___J 1'*
1032 I
I 1024.
I
~
L!.J-g ---
BECHTEL J_ OFFGAS ENCLOSURE 1034 GE
¥
~
0 1035 1036 1'*
1062
1 I
CU CS I
I TEST W* ~
I I
CONNECTION E I
L!.J N2 PURGE CONNECTION C854A 1
COMMON~'
TR2~~k~~1
' I
~----i--
~~ '
C120 PT
- 101 102 C120 p
102 C120 ANALYZER CELL 1011 1092 1'*
1008 1009 W*
,----------y:;;.-------,
1093 I
)-__1%r"~O~D+-.\----(~~~
M-28 UNIT 2 1051 J4" I FT i::::::.....
1* JBD-345 L!.J 2*
- 1037 ANALYZER RETURN Y.,-1 FT i::::::,.,_
14°1 FT i::::::,.,_
- u.
Y.,-1 FT i::::::.....
W* ANALYZER FEED
.....::::J 14°1 FT L!J
HYDROGEN DISTRIBUTION MANIFOLD I 1'-
I
<GSSC> NOTE 12 I
1' HCD-131 1*
1081 1_* -.Hc_o._-...
13-.1 _____ 1 NOTE 17 11 GENERATOR CASING
~
10G101 1'
(NOTE 4)
C120EPC120 TT
- 111 2*
- 1082 NOTE 17 1' HCD-131 i::::::,.,_
2 TO ST A TOR WINDING COOLING WATER PRESSURE CONTROL VALVE (1 Y-63>
20EH3653 L!J V.0 HCD-131 TI
- C120 0
GE 2'*
1-11 1'
1083 NOTE 17 1038 L!.J 2*
- 104;, ~
L!J TEST PLUG 1040 GE 2**
L!J BECHTEL 2*
1' JB0-345
)'2* JB0-345 BECHTEL 3' JB0-345 GE Yz"*
VENT WITH BIRD SCREEN ROOF 2'
~TEST CONN.
1' JBD-345.....::::J 1'
L!J BECHTEL 1084 NOTE 17
)'2* JBD-345 THIS SH.
<G,6>
I
~-~%~"-OOil
- ---<..._<S_H_!!~!
- ;-2~:!...*S..S> UNIT 2 COz FILL STATION ELECTRIC VAPORIZER o
UNIT 2 I~
1]3r7*3 UNIT 2
'--tlt--1?~
OOT7 (SH.2 C,4l PURGE r.l 0
' iii
(..)
001 101
~ CBD-001 :r.CBD-101 0025 0026 8
..... g 0080 TD UNIT 2 M-28
<SH.2 0,7)
UNITS 1 & 2
<BY OTHERS>
%"OO
<SH.2 B,5!
I
%"001 r.
METRON I
~
~
1)'2" FILL LINE E--r---r..11..--c:i-;*H:i--.1...!-.;.-c:HO-O-.i....,,...;.:.:......1.-o--tl 1
051-3----.
1" 1*
- EOULAI~EZING E--r--~r--\J-191-tr.:-riH-<:r-!0-D--r'l--r---t... ---f 1054 7
6 1)'2" 3"
<SH.2 c.5> r-::----::-::;r~<J-,_:.-<:::::::}Mt-2~8~ UNIT 2 C02 STORAGE UNIT 10S152*
5 Rl:'.l'RIG.*
COMPR.
10-K101
<SH.2 C,4) 4" OUTSIDE TURBINE ENCLOSURE 4
0 0
UNIT 2 3
2
- 1.
PIPING AND VALVES SUPPLIED BY APCI ARE STEEL.
- 2.
OPEN TO ATMOSPHERE.
- 3.
UNIT 2 PIPING WILL BE ROUTED WITH UNIT 1 PIPING IN THE COMMON GUARD PIPE SHOWN ANO WILL BE ROUTED SUCH THAT BURIED PORTION IS MINIMIZED.
- 4.
THIS EQUIPMENT rs BEING MONITORED BY THE VIBRATION MONITORING SYSTEM <VMSl FOR TYPE OF SENSORS BEING USED, SEE THE VMS 1/0
SUMMARY
, VP No. 8031-M-247-108.
- 5.
FOR CONNECTION LOCATION OF TE-110 <GE TAG
- GTG-1> AND TE-111 (GE TAG
- GTG-3A) SEE VP No. 8031-M-2B-30. FOR CONNECTION LOCATION OF TE-160 <GE TAG No. ATG-9> SEE VP FCR M0-553F No. 8031-M-2K-22.
- 6.
DELETED.
- 7.
THE MAXIMUM EQUIVALENT PIPE LENGTH FROM THE GENERA TOR TO FLANGES OF THE GENERATOR GAS MONITORING SYSTEM MUST NOT EXCEED 100 FEET.
- 8.
DELETED.
- 9.
LOCATE ON LOW PRESSURE SIDE OF FAN.
- 10.
LOCATE ON HIGH PRESSURE SIDE OF FAN.
- 11.
i::::::,.,_ A MINIMUM SLOPE OF%IN/FT TOWARD THE DRIP LEGS
<DRAINS) SHOULD BE OBSERVED.
- 12.
THE PURPOSE DF THE PIPE TAPS <GSST ANO GSSC>IS TO SAMPLE GAS FROM EACH COOLING LOOP FOR EACH HALF OF GENERATOR.
- 13.
ALL WELDS ARE TO BE GAS TIGHT.
- 14.
DELETED
- 15.
BALL VALVE, 028-1191, USED FOR TEST TO INSIDE OF GENERATOR AIR SPACE.
- 16.
BALL VALVE, 028-1192, USED FOR TEST TO GENERATOR AIR TEST REFERENCE VESSEL.
- 17.
FOR VALVES 1081, 1082, 1083, AND 1085, REFERENCE THE CRL FOR MAKE AND MODEL NUMBER.
INCDRP. EC 618876 REV. 1 PER WO 4672858.
REVISED C02 SYSTEM FOR FILLING AND PRESSURE RELIEFS. [B&C-5&6J.
INCORP. ECR 15-00055 REV. 1 PER WO C0258407 ANO 0
C0258541. RE-ARRANGED GAS MONITORING SYSTEM AND 6 ~iijl>. ~~A~iJ&J~ND AIX-190. ADDED Fl-102 AND INCORP. ECR 04-00486 REV. 0.
ADDED VALVE 1093 AND VAPORIZER BYPASS
- DELETED NOTE 14. [C,5J.
INCORP. ECR 06-00200 REV. 1 PER WO C0219754.
DELETED HYDROGEN BOTTLES AND RELATED EQUIPMENT T AND REWORKED PIPING. [A-0,6-8 &F,8J.
w D 1-Z <t 0
DESCRIPTION TABLE OF ADDITIONS & CHANGES USE ONLY PRINTS SHOWING LA TEST DATE MECHANICAL P&ID DOD
>~~
w :ca..
a:: U<
GENERATOR H2 COOLING AND C02 PURGE
<UNIT 1 & COMMON>
LIMERICK GENERATING STATION EXELON NUCLEAR CORP.
SCALE DRAWN
!GOS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 1212118 H
G F
E D
c A
e APPROVED.... a,..E..
CHwTu..EL.._ _____ APPROVED i
SHEET 1 OF 8031-M-28 41 I CATEGORY A1