Rev. 21 to Updated Final Safety Analysis Report, Drawing No. M-0006, Sheet 0003, Rev 062, P&ID Feedwater
ML22278A641
Person / Time
Site: Limerick  
(NPF-039, NPF-085)
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A641 (1)


Text

c B

8031-M-06 SH. 3 OF

~,~.

.c.:1-#J:>I(]-.<...,.._,

tSM.9 H,,!J l.l;r*C-138A(jli5)

I~

7 7

6 5

4 3

2 6

4 3

2

~

t.

VALVE STRDkE $Pf.ED ts CONTMl..LED BY lNLDE DRlFlCE.$

lYE.NDUR Sl,!PPLIEf)) AT ACTUATDR AIR INLETS.

2.

ANGLE VAL YE WITH 'DR,t,G-TRIM NO"MM...l Y ct.OsED FOR RECMCfJLATION COHfRDl..

l. REFER TO HIOH 1.EVa FUNCTIONAi.. BLOCK DIAGRAM.

w-120-vc.-.oooos. roR FEEDWATER LEVEL CONTROL SYSTEM tXC-\456-\,-ZI.

4.

REFERENCE DRAWING 803Ht*5.. 13 <F2:7368A> PUMP SEAL INJECTION OONTROL.

5.

CAl..18RATIDM PRESSlff TAPS ARE TO 8£ TERMINAT!D INTO-A SHUTOFF VALVE AND AN DtS"fAUMEJtT BAl.ANCING VALVE.

ti.

TEMPERATURE ELEME10'S TO BE LOCAiED AS CLOSE AS PRACTICAL TO 5 Oft 6 OIAMETtRS OOll!ISTftEAM OF ll!Dlll.E Fl.AN<lt.

7.

PA£s5URE lM THE LP STE.AM SUPPLY LINE IS -NOT TO EXCEED f73 PStA PER GE.

8.

REACTOR FEEO PUMP PRE-'OPERATIOHAL TESTING NOT TO EXCEE0 800 Psi; DISCHARGE PRESSUAE WIEN O!SCHAllG!l<<l

'\'Q. W.E CGKlOISER V1,A. 'WAS!. UNE W ~\4l (PadD M--41~SHEET 1,ZONE A,7).

9.

THIS EQUIPMENT IS BEING MONITORED BY THE VIe-RATION KINJTDRJNG S'fSlIM MISJ. FOR THE TYPE OF SENSORS BUNG ua sa THE VMS 1/0 stJAIART. V.P. DWC.

8031-W-247-10&

10. AU. PIPING ANO VALVES 5MOWN WJTHJN THE SYMaOL a<<l1£ 10>

IJN THIS nm MAY BE IN ACCORDANCE WITH TIIE REOUIREMENTS OF THE PlPlHG Cl.ASS DESIGHA TJOM -wD' *

11. D£LETED.

13, THE CH£Ck VALVE IS OF DUAL-PLATE TYPE TD MlNIMIZE SLAM 01$ TD SIJOOEN REVtFlsE Fl.OW,

14. D£1.£TED.
15. ORITTCEs MUST BE: LOCATED 10 PIPE DIAMETERS APAR"l'.

1,. DEL.£TEO.

17. et.IM> PORTlDN OF SF'ECTACL,E BLIND FUNG£ IS TD BE lNSTAt.u:D DURING NOaMAL. OflERAmJN.

tL oa£.t£.0.

1-9. VALVE POsrruJNEft OUTPUT LINES A.RE PROVIDED WITH AIR BDCSTER RELAYS.

~ THIS REM£SEHT5 THE \'Al~ l'OSITllJNER.

21. Da.ET£t>.

U. R£P~

Q.E. CONTROL DIAGRAM.(509E25"£) Y.P.

l80'5Hlr~U-1'.

23. oaETED.

Zo4, FOR TRACER tEST CONNECTIOH AND FEEDWATER SYSTEM DRAIN.

25. f)ELETEIJ.

2.6. VAL.VE 12186 MIO t238C W1IJ.. MOT OPOl 1F TM£ DIJWNSTRi.AM Pft£SSUR£ IS GREATER THAM l'.3 PSI HIGHER THAN THE UPSTREAM fRESSUR£.1ME VAJ..vt Will CLOSE IF tt£ FLOW YEl.OCtTY IN 1llE; REVERSE DlRECTIDN IS GREA ~

lHAtt 30 FT l'SEC.

21. A8ANl)ONED IN Pl.ACE.
28. ACOUSTIC SENSORS AND/OR THERMOcOl.FLES HAVE BEEN INSTALL NEAR THESE VAL.VD TO MOHITOR FOR LEAKAGE.

THERMOCOUPLE CABLE HAS eEEtf PU.LED TO LOCAL PANELS.

iCOUSTlC MONITOR C.4Bl£ HAS BEEN PIA.I.ED TO LOCAL POINTS ANO TEST COl<HEl:TltlNS.

29, THE MIN FUJW RECiflCULArn:Jflt VAL~ S'TfV UICIC ff~S 8EEfl ADJUSfED TO LIMIT THE VllUE FAIL lJP!N POSITION Tn t;IZ OPEN. f'EFER TO ECR NIJ, 95-0SZl5 FOR D£TAILS.

30. FLANGES DOWNSTREAM Of PSV-102A.B..&_ C MAY BE 1!>ot' P£R Hl!O CLASS.

31.DELE.TE'b.

~DELETE!>.

33. DUIUHG NORMAL OPERATION HYORQGEN INJECtroN TO 0N£ AFP wtU. BE JSlll.,ATED BY CLOSING ASSOCIATE> 1110 &_ 1t21 VALVES.
34. VAL.ViS ARE EQUIPPED lll'ffil PNEUWATlC lOCKUP FUNCTION TD PROVID£ A 'FAll. AS IS"<FAUMD0£ OF OP£RATION ON A LOSS Of' AlR $1,IPPJ.. Y. TIE.ACTUATORS OF l'HE VAi. YES WJLL RETAJN nER EXISTING SPRINGS AfiD nEAEFORE. UltlMATELY THEY WIU.. HAVE 1 FAIL CLO$£ FAIL MOO£.

Y.>. ~lllS C!lloll'illEll~ ""5 l'll1IC'!l!lMS SIOHllntlW.TIPl.tPl<lll'S ANO MULTJPl,.E; Slt!ETS OF M-0006.

36,.. R£FERENc£ SCHEMATlC !){A.GRAM E-0281, SIGNALS LEFM "C'

<C.>l P&.ID FEEOWATER H

G F

E 0

c

<UNIT 1l 1------UMERICK,_.....,---GEHERA----T-ING_ST_A_T~lON-----!A EXELOtt NUCLEAR CORP.