ML22278A636

From kanterella
Jump to navigation Jump to search
Rev. 21 to Updated Final Safety Analysis Report, Drawing M-0015, Rev. 4, Sheet 36, P&ID Compressed Air (Instrument Air: Radwaste/Offgas & Diesel Generator, Unit 1 and Unit 2)
ML22278A636
Person / Time
Site: Limerick  
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A636 (1)


Text

H G

E D

c B

lLi A

r:

~

B 803HH5 SH. 36 t.1-15 ELEV. 191'- 0" HV-6J*OU HV-63-050 HV-63-043 ISH.2C,6l 0068E.06.0~0RA !N t!J ISH.2H,41 0060E.07.0~0RAIN SPARE r.l

~

~

  • I I rJ00-10~

8

~

SPARE ~----------------~

1--l"f--,:J ORAlN 0068E.02.02 lSM.10,5!

!SH.IE.SI 2'JC0*108 2'

ELEV. 162'-0' B

SPARE r.l 006SE,15.0~0RAJN (SH.1 0,4)

SPARE r.l

($H.SA,7J SP*RE

IORAtN r.1 0068E.2J,02 2'J00-!08 t!J SPARE SPARE r.l SPARE r.l

~

6

!SK.20,JI M-62 HV-62-0JTA

!S~l.2 C,41 0068E.21,0~[)IUJN ISH.20,8)

JORAIN
JDRAIN 0068£.2'3.02 1SH.5C,SI

~----'.J ORA IN 0068E.28.02 6

0068E.l l.~20RAIN 2"J00-l08 ISH.lE.lf 5

HV*f>6*009

!SH.20.7>

SPARE r.l 0068E.12.~2DRAIN:...

'.]OfU.IN 0068E.48.02

'.]DRAIN 0068E.~8. 0J CSH,1 0,51 CSH.18.7)

)DRAIN 0068£. 14.02 HV*66*014 CSH.28.61 0068E.S4,02~0RA!N HV*66*02Z8 H'Hi6*028

~--iot--~ DRA IN 0068E.5'3.02 t

HV*67-1138f,::._

!SH,IJA.Sl RAOWASTE ENCLOSURE INSTRUMENT AIR RECEIVER 3

I FUTURE FUTURE 64-00\Al.:-+-------'------

J 64-00IB J---i---1.~::J SPARE 00680.44.07 I

I

~------

TO CONTROL STRUCTURE H2 ANAL~ZERS 2

f--QIQ--!°'-~ PCV*10*274

! SH.~ A.Sl 1'Xl't' 1--,;oQ--N-~-0-<l ~PCV*TO*IH

($H.2A.5) t---i:OC..._--i~9-086A 1253.01.01

<SH.\ f,4!

w:g:ggi~

TC-79-0876 f'2'X1~

  • I I

L_ _________ -__ :_L:_v. 195'-0" - - -- - - -- - - -- - -

I

__ DFFGAS E~i:._D~ ______ _J 2'JOO*I08

'°"'

0092.l t!J DRAIN

~!

n

~~

~~

~~

~~

~

~

~ J DRAIN HEADER '8"

]'J00*108 HU.0£R"A" 0091A I

CONDENSATE I RETURN PUMP R00"5

" J CSM.7 O.JI FROM TURBINE M-'5

}

M-15

~

N :j

~

ENCLOSURE ELEV. 200' 2878.0J.~DR'IN REACTOR I

~

1~ ~

I ~1~ l

~1~ I

~i1lJ~ I DIESEL CEN.

ON OON 00~

O~*

CSH.22C.Sl H

G E

D c

HV-67-11ZB,--+/-~JHV*67-111A HV-61-11*8~

HV*67*1108 CSlt.lC,61 HV-66*001

JORAIN 0068~.32.02

~~---:J[}RA!N 5

t!J SP*RE HV*67*115 HV-67-106*

ISti.IF,]1 ORW SPARE r.l HV*67*107A IStt.lE.S>

L-..--j"f--:J DRAIN

JORAIN 0068E.J9.02 HV-61-121 CSH.20,61 SPARE r.l
JDRA!tl 0060E.~

1.02 3

SPARE.

r.l CSH.5f,T1

J DRAIN 0068E.45.02
JDRA!N OOUE.44.02 Best Copy Available 8007 M*66 PCV-66-004 ISH.2f,41 2

- NOTES REFEllENCEO ON HilS SHEET ARE llSTEO ON SHEET l

  • t-t.+-------------+=+-hl B 4~ AODEONOTAT!ON"CATECORYA\'BELDW TITLE BLOCK.

~i f,,_

INCORP'D.ECR93*D2726.

3 Ii CHANC'EO VALVE 1253.0J.01 ANO ASSOC.CHE:CK VALVE T01"ALSOAOOEOUNJON[H-1l.

w o~

z~

0

!NctJRP, ROC 90-8H1 DELETED VALVES 2878.05.05.04 & 2&78.0J.05.04

£0-ll.CHANGEO VALVE 021s.os.01 TO CLOSED CD-21 DESCR!PTIDN TABLE OF AOO!l!ONS &. CHANGES USE ON..Y PRINTS SffO'lllNC LATtST DATE MECHANICAL

&I COMPRESSED A IR IINSTRUMENT A!Ro RADWASTE/OFFGAS &

DIESEL GENERATOR, UNIT 1 AND UNIT 2l LIMERICK GENERA TI NG STATJON PECO ENERGY CO.

APPROVEoBECHTEL APPROVED 803 1-M-15 4

~

I CA TEGORY Al~

SHEET 36 OF