8031-M-06 OF SH. 2 1
2 3
4 5
3/4" 1AS105 RFP TURBINE 1AP101 FEED PUMP REACTOR 16" 18" 3/4" IR IR 3/4" DBD-115 1029A 18" 3/4" 3/4" SBD DBD 3/4" SBD-106 DRW 135A PSL 116A XJ 1/2" 1055A 1" SBD-106 DRW DRW (NOTE 4)
PANEL 1AC127 PUMP CONTROL REACTOR FEED 1070A 4"
1069A 4"
11/2" EBD-127 4"
1067A 4"
1066A 131A TV-C 4"
1071A 1" SBD-106 11/2" EBD-127 DRW 4" HBD-141 133A TS 133A TT 134A TT 134A TS 4"
1068A X
X X
X X
X X
X X
X X
X X
X X
11/2" EBD-127 FO 1062A 11/2" 11/2" 1061A 11/2" 1060A 11/2" 1064A 11/2" 1063A FO 132A TV-C 11/2" 1065A TRIP 20" GBD-118 1028A 1
2 3
4 5
16" 18" 3/4" IR IR 3/4" DBD-115 1029B 18" 3/4" 3/4" SBD DBD 3/4" SBD-106 DRW 1/2" 1055B 1" SBD-106 DRW DRW 1070B 4"
1069B 4"
11/2" EBD-127 4"
1067B 4"
1066B 4"
1071B 1" SBD-106 11/2" EBD-127 DRW 4" HBD-141 4"
1068B X
X X
X X
X X
X X
X X
X X
X X
11/2" EBD-127 11/2" 1064B 11/2" 1063B FO 11/2" 1065B TRIP PI 102C A1107 C603 20" GBD-118 102B TW 1028B 1BS105 RFP TURBINE 135B PSL 1BP101 FEED PUMP REACTOR 116B XJ 133B TS 133B TT 134B TT HEADER DRAIN FROM STEAM SEAL 1" HBD-359 132B TV-C 134B TS 101B TW 1
2 3
4 5
ABOVE SEAT BELOW SEAT DRAINS BELOW SEAT DRAINS DRAINS ABOVE SEAT DRAINS 12" GE C668 M
2" 3/4" C1031 M
M 11/2" M
11/2" HS 111C C668 C668 VALVE STOP MAIN HP GE 16" 18" HS 112C C668 IR IR 3/4" DBD-115 1029C 18" 3/4" 3/4" SBD DBD 3/4" SBD-106 DRW 1/2" 1055C 1" SBD-106 DRW 1070C 4"
1069C 4"
11/2" EBD-127 4"
1067C 4"
1066C 4"
1071C 1" SBD-106 11/2" EBD-127 DRW 4" HBD-141 4"
1068C X
X X
X X
X X
X X
X X
X X
X X
11/2" EBD-127 11/2" 1064C 11/2" 1063C FO 11/2" 1065C TRIP STOP VALVE LP MAIN HS 114C C668 1028C HEADER DRAIN FROM STEAM SEAL 1" HBD-359 1007A 10" CR 1007B 10" CR 1007C 10" CR SBD DBD 1"
1" 1049C 1048C 1" SBD-106 CRW DRAIN HS 113C C668 1046A 1047A SBD DBD 3/4" SBD-106 DRW VENT 3/4" 3/4" 1046B 1047B SBD DBD 3/4" SBD-106 DRW VENT 3/4" 3/4" 1046C 1047C SBD DBD 3/4" SBD-106 DRW VENT 3/4" 3/4" 113C HV 114C HV 107C ZS 12" GAD-108 4" EBD-113 104C ZS 112C FO 123C FG 102C TW 135C PSL 116C PSE 112C HV 1CS105 RFP TURBINE 1CP101 FEED PUMP REACTOR (NOTE 4)
PANEL 1CC127 PUMP CONTROL REACTOR FEED 133C TT 134C TT 134C TS 132C TV-C 101C TW 116C XJ 133C TS M
20" M
20" 1044B 1"
DRAIN CRW 1045B 1"
GBD 103B HV HS 103B C651 HS 103C C651 M
20" 1044C 1"
DRAIN CRW 1045C 1"
GBD SBD 103C HV FO 1062C 11/2" 11/2" 1061C 11/2" 1060C 1st STAGE DRAIN MOISTURE REMOVAL 5"
S HS 115C C668 6"
FO GE ND 115C SV 115C HV 131C TV-C FO 1062B 11/2" 11/2" 1061B 11/2" 1060B 131B TV-C 1st STAGE DRAIN MOISTURE REMOVAL 5"
S HS 115B C668 6"
FO GE 115B SV 115B HV ND 11/2" HBD-140 6" HBD-141 21/2" EBD-127 20" GBD-118 11/2" 1033C C1034 M-06 M-06
- NOTES REFERENCED ON THIS SHEET ARE LISTED ON SHEET 3. -
11/2" EBD-121 111C HV R
G R
G M-06 (SH.1 F,2)
M-06 (SH.1 F,4)
M-06 (SH.1 F,6)
M-06 (SH.3 B,3)
M-06 (SH.3 B,5)
M-06 (SH.3 B,7) 10" DBD-106 10" DBD-106 10" DBD-106 20" DBD-101 20" DBD-101 20" DBD-101 2"
2" GBD-139 2" GBD-139 EXHAUST DUCT RFP TURBINE 81" X 36" EXHAUST DUCT RFP TURBINE 81" X 36" EXHAUST DUCT RFP TURBINE 81" X 36" NOTE 9 M-06 (SH.1 D,3)
M-06 (SH.1 G,3) 1st STAGE DRAIN MOISTURE REMOVAL ND 5"
S HS 115A 115A SV C668 6"
FO 115A HV GE 6" HBD-139 11/2" EBD-121 A1116 M-06 (SH.1 H,2) 20" GBD-118 M-06 (SH.1 H,3) 20" GBD-118 M-06 (SH.1 H,5) 20" GBD-118 117C PT C111C 130C TT X
X X
DRAIN 1094C 1"
1059C 2"
1057C 2"
1058C 2"
6" HBD-141 1" HBD-140 M-06 (SH.1 D,5)
M-06 (SH.1 G,6) 6" HBD-139 11/2" EBD-121 A1115 117B PT C111B 2" EBD-127 X
X X
DRAIN 1094B 1"
1059B 2"
1057B 2"
1058B 2"
2" 1095B 1" HBD-140 6" HBD-141 1" GBD-159 3" EBD-127 21/2" EBD-127 6" HBD-141 1" HBD-140 130B TT M-06 (SH.1 D,8)
M-06 (SH.1 G,8) 6" HBD-139 11/2" EBD-121 A1114 X
X PDSHL DRAIN 1094A 1"
1059A 2"
1057A 2"
1058A 2"
6" HBD-141 1" HBD-140 C111A 117A PT 130A TT 140A HEADER DRAIN FROM STEAM SEAL 1" HBD-359 1" GBD-159 M-06 (SH.1 B,3)
HS 116C C668 M
NO 116C HV 2" HBD-382 1" HBD-382 2" RBD-106 1" SBD-106 DRAIN VENT 2"
RBD HBD M-06 (SH.1 B,5)
HS 116B C668 1031C 1032C M-06 (SH.1 B,8) 1" 1030A HS 116A C668 M
NO 2" HBD-382 1" HBD-382 2" RBD-106 1" SBD-106 DRAIN VENT 2"
RBD HBD SBD HBD 1032A 1031A 116A HV 1"
1" 1114 1115 DRAIN 1"
1" 1116 1117 VENT 1106 6"
DRW EBD GBD 125 FO 3" GBD-122 1"
1" 1103 1102 4" EBD-127 HS 140 06-140A, B & C FROM PDSHL SBD GBD (C,6)
PDAL 140 C868A (C,4)
(C,2) 1107 4"
S FO 4"
NE 140 HV 1105 1104 3/4" 3/4" GBD SBD VENT NOTE 10 6" GBD-122 GBD EBD 4" EBD-127 4"
1108 NOTE 13 INTERLOCK OR 1CP102 RUNNING 1AP102, 1BP102, CONDENSATE PUMP (SH.1 D,3)
(SH.1 D,3) 1" M-07 (SH.2 E,7)
FILTER BLOWDOWN AIR INSTRUMENT FILTER BLOWDOWN AIR INSTRUMENT M-05 (SH.2 E,4)
M-05 (SH.2 B,3)
M-05 (SH.2 B,3) 1" M-07 (SH.2 E,7)
AIR INSTRUMENT FILTER BLOWDOWN M-07 (SH.2 E,7)
CRW DRW C449 147C HSS C1010 C449 147C TSH C449 147B HSS C1009 C449 C449 M-06 (SH.1 D,7) 147A HSS C449 A
(NOTE 4)
PANEL 1BC127 PUMP CONTROL REACTOR FEED SBD 1" SBD-106 1" SBD-106 DRW CRW 11/2" EBD-121 NOTE 9 NOTE 9 NOTE 9 NOTE 9 HBD SBD M
NO 2" HBD-382 1" HBD-382 2" RBD-106 1" SBD-106 VENT 2"
RBD HBD 1"
CRW DRW HBD SBD 1032B 1031B 116B HV M-06 (SH.1 D,3)
M-06 (SH.1 D,3)
SBD DBD 1"
1" 1049B 1048B 1" SBD-106 CRW DRAIN SBD DBD 1"
1" 1049A 1048A 1" SBD-106 CRW DRAIN PI 102B A1106 C603 102B PSL 102B PT C111B C111B ABOVE SEAT BELOW SEAT DRAINS BELOW SEAT DRAINS DRAINS ABOVE SEAT DRAINS 12" GE C668 M
2" C1030 M
M 11/2" M
11/2" HS 111B C668 C668 VALVE STOP MAIN HP GE HS 112B C668 STOP VALVE LP MAIN HS 114B C668 HS 113B C668 12" GAD-108 4" EBD-113 11/2" C1033 M-06 M-06 11/2" EBD-121 R
G R
G 2"
2" GBD-139 2" GBD-139 (SH.1 D,6)
(SH.1 D,6) 11/2" EBD-121 M-06 (SH.1 D,5)
M-06 (SH.1 D,5)
ABOVE SEAT BELOW SEAT DRAINS BELOW SEAT DRAINS DRAINS ABOVE SEAT 12" GE C668 M
2" C1029 M
M 11/2" M
11/2" HS 111A C668 C668 VALVE STOP MAIN HP GE HS 112A C668 STOP VALVE LP MAIN HS 114A C668 HS 113A C668 12" GAD-108 4" EBD-113 11/2" C1032 M-06 M-06 11/2" EBD-121 R
G R
G 2"
2" GBD-139 2" GBD-139 (SH.1 D,8)
(SH.1 D,8) 11/2" EBD-121 M-06 (SH.1 D,8)
VALVES LP CONTROL M-06 (SH.1 D,8)
A1105 C111A C111A 102A PSL 123A FG 1033A 1033B 111B HV 104B ZS 112B FO 107B ZS 114B HV 112B HV 123B FG 102C PSL C111C C111C 102C PT 144B FG (A,4)
TO PDAL-140 TE 110C 10" 10" 1020C HS 109C 12" GAD-108 HV 109C M
GBD GAD 6"
1009C C668 10" GAD-108 6"
1" GBD-139 GBD 1" GBD-139 HV 122 FO 122 1"
2" GBD-139 6"
1/2 "
1099 YS 122 FO TE 111C HS 110C HV 110C M
C668 4"
4" EBD-113 4" EBD-113 EBD SBD 1086B 1087B 1"
1" 1" SBD-106 EBD SBD DRW 1086C 1087C 1"
1" 1" SBD-106 4"
11/2" EBD-121 EBD SBD 1"
1" 4"
11/2" EBD-121 18" GAD-108 HS 121 C668 4" EBD-113 M-01 (SHT 1 B,8)
MAIN STEAM 6" EBD-113 6" DRAIN 11/2" EBD-121 NOTE 17 2" GBD-139 M-01 (SH. 2 D,2) 1" GBD-139 1" GBD-139 1087A 1086A M-21 (SH. 3 C,5)
STEAM AUXILIARY FROM TRIP SIGNAL TURBINE DRW 106C PDI C111C PI 106C C111C 107C PDI C111C PI 107C C111C 1" GBD-139 1" GBD-139 GBD TE 110B 10" 10" HS 109B 12" GAD-108 HV 109B M
GBD GAD C668 TE 111B HS 110B HV 110B M
C668 4"
4" EBD-113 NOTE 17 106B PDI PI 106B 107B PDI PI 107B (NOTE 7) 6"GBD-134 6"
M-21 (SH. 3 B,5)
STEAM AUXILIARY FROM (NOTE 7) 6"GBD-134 TE 110A 10" 10" HS 109A 12" GAD-108 HV 109A M
GAD GBD C668 TE 111A HS 110A HV 110A M
C668 4"
4" EBD-113 NOTE 17 106A PDI PI 106A 107A PDI PI 107A 6"
M-21 (SH. 3 B,5)
STEAM AUXILIARY FROM (NOTE 7) 6"GBD-134 STEAM CROSSAROUND FROM 2"
M-06 (SH.1 B,6) 1020A C111A C111A C111A C111A C111B C111B C111B C111B 1020B 113A HV 107A ZS 104A ZS 112A FO 111A HV 112A HV 113B HV 10P176 BOOSTER PUMP RFP SEAL INJECTION 1009B 144C FG (G,2)
(F,2)
(F,3)
(G,2)
(F,5)
(F,5)
(G,4)
(G,5)
(F,7)
(F,8)
(G,7)
(G,7) 1" GBD-159 M-06 (SH.1 A,6) 144A FG 4"
2" 1095A A
A 2"
1095C 4"
NOTE 9 4"
11/2" 11/2" 1/2" 1/2" 1009A 11/2" 11/2" 1/2" 1/2" 1/2" 1/2" 11/2" 11/2" DRAIN 1130B 1"
1129B 1"
1132B 1"
1131B 1"
VENT 1132A 1"
1131A 1"
VENT 1136A 1"
1135A 1"
VENT DRAIN 1130A 1"
1129A 1"
DRAIN 1134A 1"
1133A 1"
GBD-139 3/4" GBD-139 3/4" GBD-139 DRAINS 3/4 " EBD-121 3/4 " GBD-139 3/4" GBD-139 3/4 " EBD-121 3/4 " EBD-121 3/4" GBD-139 3/4" GBD-139 GBD-139 TO TY101A M-03 (SH.1 E,1)
TO TY101A M-03 (SH.1 E,1)
TO TY101A M-03 (SH.1 E,1)
TO TY101A M-03 (SH.1 E,1)
TO TY101A M-03 (SH.1 E,1)
TO TY101A M-03 (SH.1 E,1)
M-15 1"
1030B 1003 PDSHL 140B (A,4)
TO PDAL-140 1"
1030C DRAIN (SH.6 H,3)
M-15 1004 (SH.6 G,2)
M-15 1005 (SH.6 H,3)
M-15 TO PDAL-140 (A,4)
PDSHL 140C M-15 HV-140(AS)
TV-C-132C(AS)
TV-C-131C(AS)
(SH.38 G,5)
M-15 HV-115C(AS)
(SH.6 G,2)
M-15 PSL-135C(AS)
M-15 (SH.6 H,3) TV-C-132B(AS)
TV-C-131B(AS)
(SH.38 G,6)
M-15 HV-115B(AS)
M-15 (SH.6 G,3)
PSL-135B(AS)
M-15 (SH.6 H,5) TV-C-132A(AS)
M-15 (SH.6 G,5)
TV-C-131A(AS)
M-15 (SH.6 H,5)
(SH.38 G,7)
M-15 HV-115A(AS)
(SH.6 G,5)
PSL-135A(AS) 1" GBD-139 DRW 1" SBD-106 S
NE M-02 (SH. 2 G,7)
(SH.6 G,1)
M-15 (SH.6 G,2)
M-15 (SH.6 H,2)
(UNIT 1)
R E
V LIMERICK GENERATING STATION M-06 (SHT. 2 )
BECHTEL BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 8031-M-06 58 08/15/89 M-06 (SH. 1 B,6)
NE S
A/S 105A PT C111A A1108 C603 PI 105A E1011 PI 102A C603 E1008 102A PT A1109 105B PT C111B PI 105B C603 E1012 LP CONTROL VALVES E1009 LP CONTROL VALVES 105C PT A1110 PI 105C C603 C111C E1013 E1010 102A TW GBD-139 3/4" 114A HV FROM SSH-116A 103A HV DRAIN 1044A 1"
GBD SBD 1" SBD-106 (MANI)
CRW 1"
1045A C651 HS 103A 101A TW 3/4" 3/4" 3/4" 1228B 3/4" 102C PP 3/4" 3/4" 3/4" 3/4" C652 M-06 (SH.3 C,4) 2" DBD-101 M-06 (SH.3 C,5) 2" DBD-101 M-06 (SH.3 C,8) 2" DBD-101 CATEGORY A1 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28 3/4" 1228A 1227A C111A C111A 102A1 PSL 102A2 PSL C111B C111B 102B1 PSL 102B2 PSL C111C C111C 102C1 PSL 102C2 PSL 3/4" 3/4" 1056C (SH.10 D,3)
M-06 1121C 1120C 3/4" 3/4" 3/4" GBD-118 H2 INJECTION LEG DRIP 1227C 1228C (SH.10 F,3)
M-06 1121A 1120A 3/4" 3/4" 3/4" GBD-118 H2 INJECTION LEG DRIP DCD GBD DCD GBD (SH.10 E,3)
M-06 1121B 1120B 3/4" 3/4" 3/4" GBD-118 H2 INJECTION LEG DRIP DCD GBD 3/4" DBD-121 1056A 1/2" X
1056B 3/4" 3/4" DBD-121 3/4" DBD-121 NOTE 33 NOTE 33 3/4" 3/4" 3/4" NOTE 33 NOTE 33 NOTE 33 NOTE 33 C1008 FROM SSH-116B FROM SSH-116C M-06 (SH.1 D,4)
(NOTE 22)
SIGNAL VACUUM LOW (NOTE 9)
SIGNAL VIBRATION M-06 (SH.1 D,2)
(NOTE 22)
SIGNAL VACUUM LOW (NOTE 9)
SIGNAL VIBRATION
[E,8]
CONT. FROM ABOVE 10C148 C1004 C1022 SI 115A 101A SI C132A C603 A1141 ZRS 115 E1005 C603 PEN 1 M-06 (SH.3 D,6)
[E,6]
CONT. FROM ABOVE C1005 C1023 SI 115B 101B SI C132B C603 A1142 ZRS 115 E1006 C603 PEN 2 M-06 (SH.3 D,4)
[E,3]
CONT. FROM ABOVE C1006 C1024 SI 115C 101C SI C132C C603 A1143 ZRS 115 E1007 C603 PEN 3 M-06 (SH.3 D,2)
CONTROL "A" TURBINE RFP CONTROL "B" TURBINE RFP CONTROL "C" TURBINE RFP 147A TSH 147A TE 116A PSE 126A2 ZE 115A1 SPE 115A3 SPE CONT. BELOW [A,7]
126A1 ZE 115A2 SP 115A ZE 101A HSV VALVE CONTROL HP TE 147B 147B TSH 116B PSE 126B1 ZE 115B2 SP 115B ZE 101B HSV 126B2 ZE 115B1 SPE 115B3 SPE CONT. BELOW [A,6]
VALVE CONTROL HP 126C2 ZE 115C1 SPE 115C3 SPE CONT. BELOW [A,5]
TE 147C 126C1 ZE 115C2 SP 115C ZE 101C HSV VALVE CONTROL HP XY C612 A
O E1049 150-AO1 150-AO4 XY C612 A
O E1098 150-AO3 150-AO6 XY C612 A
O E1099 150-AO2 150-AO5 XY A
O 150-DI4 150-DI5 XY A
O 150-DI4 150-DI5 XY A
O 150-DO8 150-DO9 XY C453 A
O 150-AI7 XY C453 A
O 150-AI8 XY A
O 150-AI8 XY A
O 150-AI10 XY A
O XY A
O XY A
O XY A
O 150-DO8 150-DO9 XY A
O XY A
O XY A
O XY A
O 150-DO8 150-D09 150-1 150-2 XC FIC FIC FIC LIC M1-1R601A M1-1R601B M1-1R601C M1-1R600 XY C612 A
O 150-DO1 XY C612 A
O 150-DO1 XA 110 XA 111 C603 C603 C603 C603 C803A C803A XY C612 A
O 150-AO2 XY C612 A
O 150-AO4 XY C612 A
O 150-AO6 XY C612 A
O 150-AO7 E1031 E1032 E1048 E1023 XY C603 A
O 150-AI13 XY C603 A
O 150-AI13 XY C603 A
O 150-AI12 XY C603 A
O 150-AI12
[A,5]
XC-150-2 XC-150-1
[A,5]
XC-150-2 XC-150-1
[A,5]
XC-150-2 XC-150-1
[A,5]
XC-150-2 XC-150-1 XY C603 A
O 150-AI11
[A,5]
XC-150-2 XC-150-1 XY C603 A
O 150-AI11
[A,5]
XC-150-2 XC-150-1 C453 C453 C453 C453 C453 C453 C453 C453 150-DI4 150-DI5 150-DI4 150-DI5 C453 C453 C453 C453 C453 150-DI4 150-DI4 150-DI5 150-DI5 150-AI10 150-AI9
[E,1]
(PT-102C) 150-AI13 FROM
[F,1]
(PT-105C) 150-AI13 FROM
[F,3]
(PT-102B) 150-AI12 FROM
[F,4]
(PT-105B) 150-AI12 FROM
[E,6]
(PT-102A) 150-AI11 FROM
[F,6]
(PT-105A) 150-AI11 FROM 55 INCORP. ECR 03-00085 REV. 0 PER WO C0207259. DIGITAL FEEDWATER MODIFICATION.
INCORP. ECR 99-02343 REV. 2 PER WO C0206161 WOODWARD GOV. MODIFICATION. [VARIOUS].
C675 3 & 35)
(NOTES 09 3
04 EJW JCW MSD 2 3 (NOTE 9)
VIBRATION SIGNAL SIGNAL (NOTE 22)
LOW VACUUM (NOTE 22)
SIGNAL(S)
PRESSURE BEARING OIL LOW PUMP TRIP (NOTE 36)
(NOTE 22)
SIGNAL(S)
PRESSURE BEARING OIL LOW TURBINE 2 3 TRIP (NOTE 37)
HEADER PUMP DISCHARGE FROM CONDENSATE 2 3 (NOTE 22)
SIGNAL(S)
PRESSURE BEARING OIL LOW PUMP TRIP (NOTE 36)
(NOTE 22)
SIGNAL(S)
PRESSURE BEARING OIL LOW TURBINE 2 3 TRIP (NOTE 37) 2 3 (NOTE 22)
SIGNAL(S)
PRESSURE BEARING OIL LOW PUMP TRIP (NOTE 36)
(NOTE 22)
SIGNAL(S)
PRESSURE BEARING OIL LOW TURBINE 2 3 TRIP (NOTE 37) 56 INCORP ECR 05-00033 REV. 1 PER WO CO213914. ADDED 2 0F 3 LOGIC TO "LOW BEARING OIL & LOW TURBINE BEARING PRESSURE" FOR "A,B,C" RFP'S [A-B-2,4,8].
17 3
06 EJW JCW JAL SS 11/2" YS 121 1096 1/2 "
1" EBD-121 HV 121 11/2" NOTE 28 SS Mo Cr FO 121 FO SS 57 INCORP EC 626737 REV. 0.
PIPING AND VALVE 1096 MATERIAL CHANGE TO STAINLESS STEEL WITH A BALL VALVE. [H,7-8].
21 4
20 AN TMG BTB 1401A 1 1/2"-DAD-101 1402A 1401B 1 1/2"-DAD-101 1402B 1415A 1 1/2"-DAD-102 1414A M-06 (SH.7 G,7)
M-06 (SH.7 F,8) 1415B 1 1/2"-DAD-102 1414B M-06 (SH.7 G,7)
(SH.7 E,8)
M-06 1/2" SS GBD 1/2" SS GBD 3/4" 3/4" 1204 1201A 1/4" 3/4" 1239 1201B 1/4" 58 INCORP EC 632979 REV. 1.
ADDED PZIP SYSTEM SUPLLY AND RETURN LINE OLD GEZIP SUPPLY LINES. [F-4,7],[D-4,6] AND [C-4,6].
23 4
22 AN RML KDS AND ISOLATION VALVES. REMOVED AND ISOLATED 1
A B
C D
E F
G H
C D
E F
G H
A B
SCALE CHECKED INSPECTED APPROVED DATE SHEET OF APPROVED APPROVED IGDS DRAWN MECHANICAL NONE USE ONLY PRINTS SHOWING LATEST DATE TABLE OF ADDITIONS & CHANGES DESCRIPTION DATE NO REV'D CHK'D APP'D 8
7 6
5 4
3 2
8 7
6 5
4 3
2 1
$DATE$
PRINTED:
$FILE$
EXELON NUCLEAR CORP.