Rev. 21 to Updated Final Safety Analysis Report, Drawing M-10, Sheet 0, Rev. 38, P&ID Service Water
ML22278A462
Person / Time
Site: Limerick  
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A462 (1)


Text

{{#Wiki_filter:* I-I V1 - 0 I ~ H G F E D c B A 8 8031-M-10 8 SH. 6 OF 7 6 5 4 3 2 EL.ZOO'-O' ENCLOSURE ENCLOSURE FROM SERVICE WATER > M-10 ~>o-------'""-"'""-... '---..-1 M-09

  • TO COOLING TOWER 2* JBD 224 2'

RETURN HEADER

  • -~~~~

2434 JBD S.S. SS JBO v UNIT 2 CONTROL ENCLOSURE. CONTROL ~TURBINE 24' JBD-224 ~-i:J-t--;F'::' J~B~D~-~22~4i::::-...;'::;G_* J;;:B;:D:,:-;;';:'4::...-:~1*~J::B~Dr,-;;zz~*='\Jr-.::r-1-:-r"'.""---------------:~>,G~:::> - ~ _J H ! IIA II f.-~~-~-'---tlf-.-~ DRA!N (SH.8 H.1l DRAIN r: _____ 2*......,2.*""J"BD.,_-:.2_.2,::4_, O*'-----l--- c--*-*+-___,20435 7 tSH.8 0,3) FROM RECOMBlNER 2347 L.: "<I" AFTER CONDENSER, 20'JBD-224 24'JBD-224 _JL 24"JBD-224 2348 11'1 11*1 co._' N /JHD ~--- TO OR FROM COOLING ~. M-10 >* s~i~j~E u~i~E~ {SH.1 H,2) RETURN INTERTIE FuEEE~~otN~EAT M-10

  • ~-.;_..;;.;_;;;;._<J..;;,;.:.;l;;.._.,.._..,._~...;;;;;...;; ___... ~--.... ------~;;_;ll;;.. ______.,.....,~-...l------------:;;:...:::::::..;:;:.:~----1~.... --------------------------'

~ CBOO tt.CGOO ~ J~D f I JBD EXCHANGERS (SH. 7 H,2) I!> TO SERVICE WATER (~8i2=~---,----.;2;;4;:*.:J~B~D-::2;;0::2'-----..:;i, ~ SAMPLE RACK ~~ * ~ I '!3 '1' SUPPLYHEAOER M-IO O 205164 RR V FROM AUX. BOILER :>::!<::I2::::>--1:_;Y,::2:.* J::;s:;o:::-.:2::24::_ __..... __ J 1" N N '-I 24' JBD-22'1 M 10 1* tSHB H 11 r::* _...,,.._1:._"_;;J~BD~-~2:o;02:....J 12stc.1 FEEDWATER PUMP l' JB0-241 FP DRAIN L SEE P&ID C60'1 U.:U L...:J 2354 NOTE 3 SEAL COOLER ANO 1---'--"""-'"'-'-.. l--::l DRAIN 270 2350 <.DI---~ M-26 SHT

  • 7 1 DRAIN GLAND FLUSH (SH. I G, 7>
J

~ C800 1

  • 1 PEN z NC

_J L z4* JBD-202 2234 NOTE 10 ~ RISH - J Bilicaoo RAL I I I I 2K605 - - - - - 210 %' JBD-241 1' 1' JB0-217 TO RECOMBlNER AFTER CONDENSER, RECW.AND ~~M--1"oc~-=2.::o~* J~B~0~2~02:;...J FUEL POOL HEAT II IIA 'O I ,--__:~::::;__:::.;__.. 1----:J VENT S.S. DRAIN ~;__....... ,;_;::;:::~.:.._.. ~ ~

  • _:------------------1-----_::6_'J;;:B~D~-2~6~7---+.:-------~M:J~:=>

v) 2227C I 3, I 2225 FP M-24 TO CHLORINATION nQ cio 3* JB0-241 271 EXCHANGERS (SH. 7 G,2l TO AUX. BOILER FEEDWATER PUMP SEAL COOLER AND. GLAND FLUSH M 10 (SH.I G,6l l-_.._.----------ll01f------. 0668 '\._ ISH. 2 D.31 2029E + DY c:%' J8D-21: NOTE 10 NOTE 14 ~ ORW ~ C668 6 C655 _J 3' JBD-202 NOTE 10 ~ [ JBD-431 ~ ~H)-'Y,;.,--( ~~1 ~ VENT ~ RV-257 ~ ZT 205C FP Y2* o.o. S.S. TUBING r _____ __;3~b~'J~B~D~-~2202:;._ _______ _,_ ___ -+--<::E::~::::'.~FROM M-09 COOLING TOWER ISH.8 0,3J UNIT 2 VENT [ . ~ ~ 9.J" 0 0 ~ 0 ~ 0 UNIT 1 RFPT SERVICE WATER RETURN HEADER 6' JBD-51 4' JBD-3 6' JBD-51 M--11 ($H.2 E.2l M-10 <SH.1 0.8) (SH.2 G,2l 7 TO & FROM CONTROL -(=* JMBlil ~~-§_6':,;J;!!B~D!_:-2;50~--~ ROOM CHILLER CSH.Z D.2) OBK112 TO & FROM ADMINISTRATION ENCLOSURE CHILLER TO & FROM CONTROL ROOM CHILLER OAK 112 (SH.1 C,8) (SH.2 F,2) 4' JBD-2 6'JBD 50 NOTE 12 C.S. S.S. c.s. ' [ii S.S. 1 Y,* JBD-68l rv~ > M-10 '"l--,rl--110 (SH.1 F,6) 1" %' JBD-1.%'.

  • "" N D

W 0 0 rn, 0 0 u UNIT 1 RFPT SERVICE WATER SUPPLY HEADER L'-1 '.]VENT JCD-2,45 1 J8,D-241 0477 1 V,.* JCD-245 2' ~~M~-2~3~~~-.;;...;,;;;,,;...;;,;CJ--{><1~----- (SH.10 B,7l 2502 r: JBD-431 L.: DRAIN 2031E 2C1E118 S.S. ~


il*l'---=~'"-

r: J8D-431 L VENT 2029F 2C2E118 5.5. M S.5. NOTE 10 !;1 !;1 1011---.----~'.HIOli----...i 2028E 3' 2027C 1" RBD-210

F +

DRW N ' 0 rn, HV-C 205C L'-1 VENT r: JBD-431 L DRAIN 2031F u~I---' ¥,i* JB0-241 ,---'!..:::O::...:.::.:...... f---_;'J VENT S.S. 22278 ~ 3' JBD-241 I 3* I _......,. _______ 101---... [ J8D-431 VENT SS 2029C 2B1E118 2028F + DRW C668 [Ii] ~ C668 [fiSJ ~ VENT r.l ~0~ ...... -----ftMH0i----!J....-~ 2028C 3' 20278 SS r: JBD-431 L.: DRAIN 2031C S.S. ~


11911-----.

JBD-431 [-.,-V"'EN"'T,..--1 SS 20290 2B2E118 + DRW N ' 0 ~ !HH\ ~ JBD-431 DRAIN 20310 ~ !;1 U s.s. IOI!----' 20280 %' JBD-241 S.S. ,--.....:.:...:_:=;:.:._..... f--~'J VENT 2227A ~ 3' JBD-241 1--1..-.-------101---... r: JBD-431 L.: DRAIN SS 1* 2031A 2029A 2A1E118 S.S. C668 [Ii] ~ + DRW C668 [HD ~ S.S. M S.S. I;! I;! VENT r.l 1011---.----o\:*J--llOll----J.--I 2028A 3' 2027A VENT %" o/.i'JBD-241 r:...... i-::-::::.::...::..:_:i M


11911-----.

HV-C 205A 2488 JCD-244 1 J~D-241 1 }2" JCD-244 2' M-23 (SH.10 8,7) 2501 6 ~ N 0 rn, r: JBD-431 L.: DRAIN 2031B M-15 (SH.20 A,6) 20298 + DRW 2A2E118 U s.s. I;! 1011------' 20288 5 RFPT LUBE OIL COOLERS LOW PRESS. AIR BLOWER HEAT EXCHANGER M-15 <SH.20 A,6l 3" JBD-269 4 e 72* Jt2* 0.0. S.S. TUBING c.s. - S.S. PSL 201 C855 l_ fPALl ~ 1--~--',0HJ---~y,~*~o=.o~.~s.=s~.~TU~B=IN~G'-----' INIV-253.1 CORROSION AND DEPOSIT MONITOR RACK 205532 8 RV-253 ':"~----"'2'~J~B;!;D::,-2:;:0;:2;_-:-ri'~' f---'O:'~K~B!!:F;:_-2~02.!1'-. __ ~~II=) TO FIRE c:i M-22

  • PROTECTION

£15 SYSTEM U, 2405 ISH, 1 E, 1) ~ JBO KBF 2' COPPER CS COPPER C855 ~

m. or;-i 202
  • 0'

~ ~~ I ~ ~ 2 ~ Q Q~~ H~~l2'JBo41s 2395 2415 1 1 2418 ~ Yl' <lP 'Y NW 2" JBD-202 I ~2~4~' ~JB~D~-+1202'""'::-:::~:tQ=> 2" r (NOTE 31 M-IO FROM CODLING TOWER UNIT 1 SERVlCE WATER SUPPLY INTERTIE N 0 N 0 w ~ N 0 N ' 0 rn, VENT r.l L'-1 LJ 00 ~ 0 N DRAIN VENT r.1 N 2 ' 0 rn, L'-1 DRAIN VENT r.l L'-1 DRAIN L ____ _ 0 N 0 rn ~ ITT I r_;-.-f--4 ISH. I G.21 ?,.._ VENT 2382

.:Bl n

2;:--JBD-415 l v if if ;c,e~ z* 1--11 I 10.........,. COPPER 1 ss 2519 r [HDCGSS, -MOTOR BEARIN~ AN~ WINDING TEMP-~1~- T--J eee s 5 VENT[--* 2049C 00

  • TE*

21Qf:-2 21 IC 24"


1--

y NW LG AO 2~-1 2' JBD-202 2CP502 TE 21 lB 2396B 2044C ND 1Kf 24" 1fl---------- y NW rn.* ~ -I~ L'-1 DRAIN C655 2* JBD-202 2BP502 ~ 1 MOTOR BEARING AND ~ 1 WINDING TEMPERATURES ~---_J 8§8 VENT o/.i" [--* 2049A LG AO 2-1 LG AO 21~2 0 ~ 1'l ~ ~Vl 'T0N o a a y, r:1l

11)

<;Q - "' !+---' ----. N

_<(

~<[

..*~

=-*~ TN T2 L'-1 L'J y NW DRAIN DRAIN I I 2044B NO N D N ' 0 rn, I I -~ SERVICE WATER PUMPS (NOTE 5l CIRCULATING WAT_ER_P_U_M_P_STR~~ 3 2 I I _J - NOTES REFERENCED ON THIS SHEET ARE LISTED ON SHEET 7 1.,f INCORP. EC 630299 REV.O PER AR 0'1304779-02. 38 'ct UPGRADED OF PJ-010-201C ANO PI-010-252C TO STAINLESS STEEL. [D-E,31 !NCORP. ECR 13-0011 0 REV.O. REPLACED VALVES 2047A,C ANO 2261A WITH SS BALL VALVES ANO REPLACED DRAINS 37 ;:(.;WITH SS. [A&D-3J. REPLACED VALVES RV-253 AND 257 WITH EJ SS BALL VALVES AND ADDED REDUCERS [G-31. 7 INCORP. IR 1513284 AND CORRECTED TYPO. 36 i FP-259 WAS !NCORRECTL Y LABELED AS FP-269.

[G,6J.

INCORP. ECR 10-00319 REV. 0. CHANGED VALVES 2049A EJ1' J TJ 35 o;_, AND 2261 C FROM GLOBE TO SS BALL, AND PIPES TO SS. EJ\O JC TJ '42 [8,3] & [D,31 w D z <( 0 DESCRIPTION TABLE OF ADDITIONS & CHANGES USE ONLY PRINTS SHOWING LATEST DATE MECHANICAL P&ID SERVICE WATER <UNIT 2 & COMMON> LIMERICK GENERATING STATION EXELON NUCLEAR CORP. 0 0 0 >;..: 0... WI 0.. "' u <( SCALE DRAWN !GOS CHECKED INSPECTED APPROVED DATE NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 01/31/9 APPROVED BECHTEL APPROVED SHEET 6 OF 8031-M-10 E 38 Sf!L~t I CATEGORY Al H G F E D c B A}}