ML22278A455

From kanterella
Jump to navigation Jump to search
Rev. 21 to Updated Final Safety Analysis Report, Drawing M-0016, Rev. 51, Sheet 2, P&ID Condensate Filter/Demineralizers (Unit 2)
ML22278A455
Person / Time
Site: Limerick  
Issue date: 09/19/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22278A223 List: ... further results
References
Download: ML22278A455 (1)


Text

H G

F E

D c

B I

~

8 8031-M-16 SHT. 2 CR)

PANEL 20C122 No'iE1i

___1 CAUTOl

(------, Cl16 SOLENOID PANEL 20C122

<PREciiA'T'S'Ys T EM>

FROM COND. F ID B/W COMP. AIR RCVR.

M-15

<SH.20 C,41 l(,* SBD*216 VENT B'

L..!..J NITROGEN PURGE CONNECTION ITYPl 2*

~

~

MIXER 2os122 6' JB0-244 2005 <D>,_ ____

8 PRECOAT TANK 20TI 13 FROM REFILL OVERFLOW TANK 20T929

  • HG

<SH. 5 E.ll FROM DEWATERJNG PUMP DISCHARGE 3"HBD-266 M*16

<SH. 6 A.2l HBO-HBD-266 B40 :r FROM DEEP BED VESSEL DRAINS 4* HB0*840 M-16 2479

<SH. 5 B.Bl 7

6 to DRAIN COOLER INLET HEADER 5

SET AT 2i_i'S_I_ -

4 3

2 CR>

M-15 1

I I

PT-2011ASl

<SH.22 G,ll 6'

%° SBD-2>6 VENT 8" HB0-264

~

~

~

~

~

~

~I TO SAMPLING M*23 STA TIDN

~,S-H-.o-H,1>

<R>

M-08

<SH.3 F.5>

6" HBD-265 PRECOAT SYSTEM CONTROL PANEL 20C190 2" HB0-4<9 J~D I G~D 2"**

2* JCD-6 2353 1"** '"**

L.... f-..... ~-::JoRAIN 2059 20481

~

6' GBD-225 2* GBD-216 C116

~T ZA C11.6 -- L J_

Ui":i

  • Sl

~

51 ciJ *,._l"...l_f;_-~2~0:;_*~

GB~D;_;-;;22;_;8~bO:ii'NiwwIR'BY"PAS;s-

~ ~

DEMINERALIZER BYPASS

-L M

~

30" GBD-216 M-15 PT-2021AS>

(SH.22 H,4l N

N

~

AIR SUPPL y HEADER 2

30" GBD-216 Cll6

~cl]'

~~

C116 SOLENOID PANELfc>>6

<TYPICAL FOR X

2ACl21-2GCl2>>

>600 XV-224A

<SEE 0,3>

XV-242A CONTROL SIGNAL THI~ DWG.

IC.31

<SV-270Al FV-C-270A C116

~

~ \.

TO SAMPLE STATION

  • M-23 CSH.6 H,7l FIL TER/OEMINERALIZER 2AFI06 ONLY

'(' TELLTALE

~,._.,..,..

  • J 2364A B' GB0-216 NOTE g;

~ 1***1* SBD-216 21241 DRAIN '('

~ DRW 2*

I I

N N

0 8 1-I*

IRl 2*

Nl.~l---:2~0~2tJA:--t;::rs:;iI;::

2*

E:-t23ll4*7-A -2'.!3~45!"'.A--i

'1 ~~~

~ ~

~I**

N 0

ffi I

I ---

I I

lS, I Z

~ I~

VENT HEADER Cl 16

-CG~GS~

Fl POI I

211A 221A

~

rT-201ACASl

<SH.22 G,61

~____fufilf 116 r~ I~

I I

FSL C116 21 tA FSH 201 Cl 16 OTH~RD F/D UNIT CONTROL LOCKOUT AIS TO t FVC-270 A-H ON >

AIR FAILURE IN PANEL Cl 16 I

I I

6" HBD-266 8 8 8"'6"'E.:i r::i r::i 2CF106 20F106

~~~ ~

~

~

0

__J

~

TO SV-250 &

SV-207 DNL Y M-15 A/S CONTROL SIGNAL THIS* DWG.

<D,6>

21 THRU 2GCl2>

TO PANELS 2~~~<ZA THRU XV242G1

!VALVE CONb;gl R~D FV-C-270H 1'"** l'."** l'.."RBD-216 C116 Cl 16

~I~

T Cll6 IAUTOl HS CHAND>

(

2> 2H ----,\

C>l6

@1 C116

--@~

Cl~

~

Vl.....

~161

@-1 o_,

~~~~

~161 5

@----1 C1:.J t- @

I I ~1619

.,,_,,,,. I ~" I !

<AUTO>

Cl~6 FG C=@116 150 HS 242H tSV-242Hl-ISV-270HI 2024 2***

I S~D I H~D 1***

<R1*1..:1~*_:S~BD~-;:2_:;16~~20~4t2:----.,- I PI 213 TO FILTER HOLDER DETAIL FOR XE-16-203

. M-23 ORW 2056 2013

~

~

'('TELLTALE DRW 12025 io* JC0*203

~116

\29 _J_

TD Cl 16 t -SBD HBO

<SH.I A,2>

VENT <Rl N

c

I:

TO REFUELING WATER ST0~~¥~3~ ANK 1"** 1* RB0-216

  • ---+lf--M::::J'N-- IRl r

ZO<<I DRAIN

~

10* JCD-203 INTERLOCK a* HBD-264 10* HBD-266

-8"**

T.**

<R>...

.:.>"..;S::;B::;:0..;-2;.;1.;;6_~~-vl 2* Hso-<<

9

~~=1~,,~~========:::::===~ a:~~==::~::::::::: ___ L _ _. _

_'.i__1_jL_:!_ _ _l-;;,.Ji;.,u;;,J--,e*"H"aoc-zc1~4-~~-

'~'"" ~ru~ ~-

~

.. *~-...

~" '"" '""'.

1 S~Ds*

a* HBD-274

>--; ' ---..--0

J14 SBD-216 2055 ORW 7

PRECOAT PUt.IP 20P136 2015 (R)

CR>

a* HBD-266 OVERFLOW AND VENT DRAIN LINE 6

5 4

3

~

a* HB0-266 2

I M-23

<SH.6 H.2l NOTES1 ANO CONTROLS SHOWN DN

1. PIPING. VALVES. INST~M2E~T1~6 ARE TYPICAL FOR ALL FJL TER/DEMINERALIZE FILTER/OEMINERALIZERS.

AND INSTRUMENTS SHOWN

2. VENDOR TO SUPPL y ALL sv~~i~~HES MOUNTED IN BUYER'S EXCEPT TROUBLE ALARM 'Na ITEMS MARKED (**>.

CONTROL ROOM PANELS A NTS INTERLOCKED VALVE 3 'X' DESIGNATION REPRESE OR INITIATION OF BACKWASH,

  • OPERATION FROM OPERAT R ICE OPERATING SEQUENCES.

PRECOAT. STANDBY OR SE V

4. VALVE PDSITIONERS SUPPLIED WITH VALVES.
5. DELETED.

T ALLED IN DIRECTION OF

6. JAMESBURY VA~~R~~-~~S NORMAL FLOW.

SHUTOFF, I.E. R ARE WAFER SPHERE, 7

VALVES XV-16-22"4A THROUGH H

, BUTTERFLY VALVES.

PROCUREMENT ERECTION B DESIGN FABRICATION, MATERJA\ALVES AND EQUIPMENT

  • AND TESTING FOR EA~~:s~~N,<:;_.NDTE Bl ON TH~~ PcfFIDTHE

~~~w~y wl~Hi~cci~oANCE ~JT~E~~%N Rg~t~~EW~TH THE PIPING CLASS DESICNA TI FOLLOWING EXCEPTIONS:

LL BE PER THE ORIGINAL IAI CLEANING REQUIREMENTS SHA LINE CLASS DESIGNATI~~* BE USED SHALL BE AS

<8> WELDIN~ PRDERCEDT~~EgRIGINAL LINE CLASS REOUJR"D P DESIGNATION.

RED TO THE PANEL Cll6 BUT IS 9 PS-1G-220A THAU H IS WI TO lNITlATE A FAST FILL

, NOT USED IN THE SYSTEM OVERRIDE.

TS lN lOC\ 16 PANEL ARE

~ >0 AIR SUPPLIES CA/S>FDR INSTL~UT~ii~ VALVE IN THE PANEL.

6

. EACH PROVIDED WJTH Al~-~-~7-156 FOR PANEL DETAILS.

'jl REFER TO DRAWING BO R PANEL 20C 122 DETAILS.

U, DRAWING 8031-M-17-80 FD II. REFER TO 17-78 FOR DETAILS OF PANELS

12. REFER TO DRAWING 8031-M 2A THRU GC::~ING 8031-M-17-96 FDR PANEL 2HC121.
13. REFER TD D N PRE-OPERATIONALLY
14. THIS EQUIPMENT HAS ND~L~E~T IS NOT INTENDED FDR U~~

TESTED BECAUSE PRESEN HAS BEEN FUNCTIONALLY TEST HOWEVER, THIS EQUIPMENT FAST FILL, FINISH FILL, 15 SLOW DRAIN, REWASH. DRAIN.

AT PREWASH DRAIN AND

  • PRECDAT lNTRDDUCTIDN, PR~~~TED ON THE FRONT OF 20C1 l6

~~~~: :;L~R:I:I~~~ ~~;1:MI 7-~~,<~~~~Dg!I:I~~AA~> ~~~DRMATION.

B031-M17-l32 <OPERATING MANU VESSEL CYCLE SELECTOR.

16. PRECOAT INTRODUCTION, C~:R~D~DDITIONAL PERCOAT. STANDBY COMMON VESSEL CYCLE S VANCE AND ANNUNCIATOR TIMER MOTOR, CYCLE CDNT~~~T A~WITCHES ARE LOCATED ON THE ACKNOWLEDGE, TEST AND R DRAWINGS B031-M17-31 !WIRING FRONT OF 20C116 REFER;~ <OPERATING MANUAL> FDR DIAGRAM~ AND 8031-M\7-1 AODIT IONAL INFORMATION.

VE SSE' *c* ONLY.

17. BYPASS LINE ON

~G PUMPS 2A THRU H-P135A~~EA BLANK

18. THE CONDENSATE ~%~~ALS HAVE BEEN REM~~iOPUMPS GLAND.

ABANDONED. T~fd INSTALLED IN PLASCI~ci1FREMAINS IN PLACE. THE FLANGE HAS FT THE PUMPS CA URE BOUNDARY.

IMPELLE~N~N~L~~~E MAINT AJNS i~1~~1ssCONTAMlNATlON CASING AN PLUG INSTALLED TO 85~rn/ DRAINING ACTIVITIES.

EJ J JM PARTIAL INCORP. ECR P135 REVISED NOTE 18

  • 49 ABANDONED PUMP 2c-AS lC,5J.

13-00446 REV. 0 PER WO C0255992.

PARTIAL INCORP. ECR P135 REVISED NOTE IB

  • 48 '!- ABANDONED PUMP 2A-

"' lC.5l.

EJ JC AS E'.J J oc 0 ~

DESCRIPTION Z (3 DITIONS & CHANGES TABLE OF ~OS SHOWING LATEST DATE USE ONL y PRIN MECHANICAL H

G F

E D

c B

P&IO JZERS CONDENSATE FILTER I DEMINERAL L~~~--:;-;u,;;tt:~<iiU~NliT~~2>~f'!!iiiii;--~-----iA LIMERICK GENERATING s1!TION

[)(ELON NUCLEAR CO D APPROVED DATE IGDS CHECKED INSPECTE 07 89 SCALE DRAWN ECHTEL BECH BECH II*.

NONE BECHTEL BECHTEL BECHTEL B

APPROVED BECHTEL APPROVED SHEET 2 OF 8031-M-16 E 51 IFILU I CATEGORY Al