ML22278A362
Text
F M
L J
H K
e*"
SEAL -
IN r I~ I
~HILAU"L~HIA "LEC TRIC COMPANY I
e4 SCALE I
m:Slt74 I
DRAWN I
CHECkED I
DATE H?CI 5TEAM
- UPPL"'f PRE,.55 LOW 12 HPC.I 5TfAM
~PPL"'(
Pf'.E~50 LOW Nlhl!>6 I
11 VALVE.M"""OFIOD.TEAM ~IK£WARM-uP' (TH....TTl-~ TYPE J LOGIC e ISOLATION SIGNAL
~1 Q ITHIS REV SCAN'.lED INTO CAD WITH NEW BORDER So
).
TillE BLOCK SlPERSEOING MYI,.AR REV 16. SIGNATURES
~
PER DRIGIN.~
OPEN I
CLOSE I
HIPCI STiAM I
5UPPY
- REVE-RSING ceNT ACTOR 42
- PRESS LOW noN ~OM SUfI'PII:ESSlOlt.! CJ.lAM8EfIl::
N658a I OR VALVE MO~4\
I
~E6 NOTeS Z.~5
~p(.,r 5TEAM
~PPLY PReS5 LOW CONTftO,--SW JroJ"oSt;F I c~
CONTROL SW SEAI.-IN I.. *OPEN"
!lEAL-IN IN"CLO~£O" pO'ITION
.---J POSITION AUX 'OIlT AUX COpt eR 42.
L-I2-RMS H-II 4'..
L-IZ, NOTE I.
LOGIC e NOTE 16 ISOLA"TIO>J SIGNAL
(
NOT PERM""VE.IN
\
N "PULl.. TQ STOP" POSITION I.
F~8
\
RMS H*l\
/
PERMIOSSllJliii: tw.L.e!)
! Nar PEI<M'I"E \
(
NOT P....I..IV'< '" \
Au,J.JUAFt'(
WI-\EJ>J VALVE "PUl..l 'TO 5TO~"
4Sl~LPFolE~T FUll\( CL05EO pOSITION
\
AUX CR J
\
L.IMIT ON
/
\
ItMS H-11 7 DEVICE SWITCH VAL.VE t
-)
t II
~RMI%I~E WWE-.J VALve Ie vALUE UMIT ""11tl<"'\
CLO~ltoJ&:.
.Pli:RMI'SfaIVE ElICEl'T WHEN RJ~,( OPEN
\
4~c
....ec j
'\
LIMIT ON /1 SWITCH.
VA~VE J.
\
PERMl95I\lE
~~~~
~ V"LV~ TI~:\\\\ u....,1" 0"
/
~ V'L~ TOOL\ ;. VJ~":~i \
~~~UED GWI1Cll
~~VE
~~~'1Il~
. FULW OPE~
\,",IlIlUE ON. /
-~"ffJl!
01\1 J \
Ul.\IT I1>J J awncM I ~L\I~.
5W,1 CH. '-'4LVE 6W'ITCIot
- VAlu!:
.t I
OPEN I
CLose I
I UNIT 1 ONLY I I
AC REVERSl..'
COlr'TACTOR 42 _.
I, CR DC L-&
cl:>
NloG02.F SUPPRESSION CHAMBER HIGH LEVEL SEAL-IN
~
CONTROL SW IN "CLOSE" POSITION RMS I
H-7 UX CON 42.
NOTE 16 C'
CR F-ll CR CR SU~~:~~~~ON HIGH LEI/EL
~IS N"C.Z~
UX CON
~2
PIS fIollll580 PI$
NI.S8H CR CR J
181}
8 I
q HIGH TURBINE EXHAUST DIAPH PRESS.
HIGH TURBINE EXHAUST CIAPH PRESS.
PIS N/C>5150 PIS fIol"'~5H OPEN I
CLOSE DC REVERIING CONTACTOR 42.
7 CR AUX DEViCE SEAL-I>!
I'50LATlO>! SIGNIIL UNTil RESET SEAL-IN O?IGIl'lP.\....
-.N\,\~l'l ?Ev PUMP SUCTiON FROM SUPPRESSION CHAMBER VALYE MO F042 SEE NOTES 2 B I CONTROL SW IN *OPEN*
POSITION pe I
CR ISOLATION SIGNAL LOGIC *0*
RESET RMS I
CR NOTE 16 STEAM LINE
~UGH dP OR L\lSTRUMEAlT UlJE aREAA 6
dPS w."O~ I CR CR 5TEAM LINE HIGH dP DR INSiRUMENl" LINE BREAK dPIS IJ.S1~
CR LOGIC 0 ISOLATION S r GNAL (NOTE D I
5 I
6 I
7 I Y 8
CONDENSATE:
':ONDENSA r!::
STORAl:E TANK STORAGE TANK LO"li l.EVEL LO'II LEVEL
~IS CR
~1" CR Nc..t..le, N/Q"'lr EMERGENCY AREA COOLER HIGH TEMP TI S 1010 CR CONTROL 'SoN IN "CLOSE" POSITION RMS I H _*Z EQUIP RM VENT AIR iNLET a OUTLET HIGH OIFF TEfo1!P TIS-Z5-1010 CR OPEN I
CLOSE AC REVERSlN; CONTACTOR ~
- 11 8 1010
~~~1i11.Q~~~r9"\
MAl NTAINED CON~ACT KEYLOc...K KEY REr--'1OVABLE. 1f\J
"~ORMAL" POSlTl0N RMS I
CR ST1!AM PIPe ARl:!A HIGH TEMP O~)
(SEE NOTES 2, I)
ITEAM SUPPLY LINE ISOLATION VALVEMO F002
'~P'05nON SW"'OPEN':."ClOSE"l
"'STOPH MAUITAfNEO CONTACT
~1~Y*'oo;E~*Mp~'f5r~~3VAOlE I
C?NNr~iN'W POSITION
[
I
"')
I A
I
=:
I 1-J F
E o
c A
1~00-~-0(0l-l'3-I-W B