ML22194A115

From kanterella
Jump to navigation Jump to search
2 to Updated Final Safety Analysis Report, Figure 9.2-2, Sheet 1, Rev. 11, Service Water Cooling a - Train Outside RB
ML22194A115
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A115 (1)


Text

{{#Wiki_filter:RN 18-045 January 2019 A B C D E F G H J K 14 13 12 SYSTEM DATA rn:) GPM PSIG * "F BY REMARKS 2 9000 50 95 NORMAL 7700 50 130 POST ACCID 3 1000 50 95 NORMAL 820 50 116 POST ACCID 4 1000 to 45 124 NORMAL 600 500 45 130 POST ACCID 17 0 to 45 124 NORMAL 400 500 45 130 POST ACCID 18 0.032 50 100

  • APPROX.

8' 20" COUPLING J-3 24' 24' 24'x20" LOOP "A" -221 SW 30'x24" 2' 24'xl6" COUPLING ~: RNm-8 18 REQ'OJ 8" ECR50465 11 10 9 ROhl IPX44 76A-HR-SW PX 4476A 8 DSP-661 ROhl !FT 4462-HR-SW ROh-1 7 ROhl !FT 4462-LR-SW 6 ECR-50933B XPS0254A COUPLING RNm-6 5 COUPLING RNm-7 (7 REQ'Dl COUPLING RNm-7 (3 REO'Dl 3/4" 8' 152N ~151~ 1 1 ~ _f------f'--J---{_ _1------1 ;'A~ DlSC E O _____i::s:s]

-7 -----c
:::::J C O 2 I

k)-~~ ~ 3104A-SW ROp-49 C-2 LOCAL CHEMICAL I ADDITION SKID [I§) 6" 20' RNg-14 / 3122A-SW --©., 155X 3131A-SW 1/2' QUICK CONNECT BY VENDOR 153X 20" ROh1 5 1PX4455A-HR-SW V~~ ROh-1 1 3138A-SW 3/4': 2 2' NC COMPONENT COOLlNG HEAT EXCHANGER "A" 3/4' l"x3/4" -0 5 MRF -22144 3132-SW l" ECR-70724 \\. 13100-SW ~" ______. <r 65 'N IO (_J w 0: I F 0 AT PSIG I I DG "A" HI LUBE OIL/HI WATER c_ JACKET TEMPERATURE LOGIC SEE GAi OWG 0-802-014, SHT 5 3/4" 20" 3 (f) a: I FT 4460 J-13 -611 cc 1" SET AT 64 PISG 4" IFT4460-LR-SW 3145A-SW 20' RNh-15 3124A-SW NC ~ 3 l':'.c~----,.~Rr~2~0~*------~~(f) <[ l" R0h3 01 M ,__.-314,W ~~ VENT o ~~---='c--- /0_ 2" ZS ~,---- ~ 6 16 '---=-2'_' _____ ---,--------ll-:@o~H~Flb1/2~z'lf-T2~'~~@o(~-----~15~5~X _____ ____,2~'~ ROh-3 ~ ~y 1' VENT [:,---1... ---j HVAC CHILLER A CONTROL (GAi DWG B-208-109 SHT VU011 -a ZS MRF-22144_,, 3133-SW 0 TW 4473 ROh-1 REMOVABLE SPOOLS 2' C-10 -841 2' D-10 -841 ~ 5 XHX-!A-VU MRF-22144 3141-SW CD 7 O~H I~ L I ROh-1 !FT 4461-HR-SW 6" MRF-21746 G:filID ~ I 24" 9 6 152N i 2" 0 ~ kR50465 13141-SW 24'xl6" 16" 24'x20' B-2 -222, SHT.2 ROi-21 3130A-SW 4 RETURN TO SW POND 13140-SW ECR50695C 6" 6" IPX4465A-HR-SW3/4" l" 3/4' 6" RNg-16 3127A-SW XGK0001A VENT !NOTE 13J X LD CSl 1/2" LD N !NOTE 14) HYDRDSTA TIC TEST TEMP. 60" 19 50 100 N/A N/A 16 16 130 20 135 <1% 25 JPM 15 65 130 65 135 (1% 82 JPM 10 125 95 165 95 (1% 210 RJS 9 16 150 20 150 (1% 25 ccs 8 16 95 20 214 (1% 25 ccs 7 16 124 20 130 25 WTW LRC 6 65 124 65 130 82 WTW LRC 5 65 95 65 95 82 ccs NOTE 3 PSIG F PSIG F DURATION HYORC BY CHO REMARK ~ NORMAL UPSET DESIGN DATA 16' F-14 -222, SHT. 2 RNn-55 3126A-SW HVAC CHILLER C CONTROL f-iSSl (GAi DWG B-208-109 --,I ---c:::::::J SHT VU03 & VU04l R h-1 L 13120-SW


.------< M ROh-1

~ _r j IPX4495A-HR-SW 3128A-SW r ___ ~ RN -16 6" ~ "\\::,I' ~ u ZS I A VALVE LINEUP TW ROh-3 '":~~c,Tw "'- I INCORRECT3/4" 4482 ~ 6" 1" vi...,u VYY l" HVAC SYSTEM MECH. WATER CHILLER CON "A' llMS-54-660, SHT. 1 & 21 C-7 -841 XHX-!C-VU 0-7 -841 vu ZS 1--<6> HVAC CHILLER I C CONTROL R h-HVAC SYSTEM MECHANICAL 13121-SW WATER CHILLER CON 'C" (GAi DWG B-208-109 I SHT VU03 & VU04) I RNn-55 I ZS ,l 3128C-SW "'-----~----<M-1--a -0:1.> 3/4" CHILLED WATER D-302-841 LDC D-6 RNg-16 114"= 1' -0" 0' 5' 10' 15' STATION DRAINAGE E-911-106 LDC H-8 3/4' ROh-1 17 3" RN,-10 3144A-SW IPX4495B-HR-SW ROh-1 !FT 4463-HR-SW 1" M 151X 152 ~sat,\\ ~ 1:::::::::j::'.:..!-; I~[ L RNi-10 fSET FT FM J 3144C-SW '-.! 4463 I 4463 CO! R h-1 l" --1 _jFB\\ 3/4"x1/2*~LO ~ ~ !FT 4463-LR-SW 3/4" 4 6" AT 70 PSIG <8) I I I I ZS ECR50585B 16 5 --....___ RNg-1 3129A-SW / 13147-SW 3/4" r----Ico ~ VENT 6" 1----------1 RNg-16 ___.,-- 3I29B-SW --....___ RNg-16 3129C-SW .(") C"l N 'Nr-0'.l NI ' (f) RNg-16 3129D-SW MRF-21746 3196-SW 3' MRF-21746 3195C-SW MRF -21746 / 3197-SW / 11 10 9 8 7 6 NO. 10/12/18 5/4/17 2/14/17 3/12115 10/26/12 4/17/12 DATE JMR JMR JMR RHM RHM DDJ BY 3 2 NOTES:

1. ALL PIPING TO BE LINE SPEC 152N.

EXCEPT AS NOTED.

3. TEMP CORRESPONDING TO PERTINENT HEAT EXCHANGER OUTLET.
5. ALL STATUS LIGHT INDICATE BOTH OPEN AND CLOSED POSITIONS.
6.
  • DENOTES MISSION DUO CHECK OR EOUAL.
11. XVC03130 A/B MAY NOT PROVIDE ADEQUATE ISOLATION FOR USE AS A BOUNDARY DURING SYSTEM DRAINING.

REFERENCE NCN5063 DISP. 0 4

12. B16.5 150 # TEE. 316 SST TO RESIST CORROSION AND MIC.
13. 8' SW-TO-EF X-CONNECT PIPING FROM 24" HEADER TO INLET FLANGE OF TEE IS LINED WITH CURED-IN-PLACE PIPING TO ELIMINATE CORROSION AND MIC BUILD-UP.

!SEE TR04330-005 & ECR506951 WEKO SEALS INSTALLED INTERNALLY TO PIPING TO SEAL ENDS OF CURED-IN-PLACE PIPELINER.

14. 8" SW-TO-EF X-CONNECT PIPING FROM OUTLET FLANGE OF TEE TO INLET OF XVG01037A-EF IS COATED WITH PLASTOCOR TO ELIMINATE CORROSION AND MIC BUILD-UP.

THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE INITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION AND WRITTEN APPROVAL FSAR FIGURE 9.2-2 SH. 1 ESSENTIAL SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION PIPING SYSTEM FLOW DIAGRAM SERVICE WATER COOLING A - TRAJN OUTSIDE RB REVISED PER ECR-50933B AME BJS u REVISED PER ECR-50695C RHM WTW DESIGN ENGINEERING SCEl<G REVISED PER ECR-50585U RHM RS A SC.OW. COI.F'MIIY V. C. SU~MER NUCLEAR STATION JENKINSVILLE, S. C. CHECKED LE APPROVAL REVISED PER ECR-50863 MGR SP

1.
2.
3.

REVISED PER ECR-50695C RHM WTW JNC PAH MGC REVISED PER ECR50585A MGR RS SCALE Ill SCJrLE D-302-222 1 11 LE REVISION CK. BY APPROVPL DRAW I NG NUMBER SHT. NUMBER "" A B C D E F G H J K}}