2 to Updated Final Safety Analysis Report, Figure 9.2-2, Sheet 1, Piping System Flow Diagram Service Water Cooling a - Train Outside RB
ML22194A111
Person / Time
Site: Summer 
(NPF-012)
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A111 (1)


Text

{{#Wiki_filter:A B C D E F G H J K 14 SYSTEM rn:) GPM PSIG*

  • F 2

9000 50 95 7700 50 130 3 1000 50 'l5 820 50 116 4 1000 to 45 > 65 600 500 45 > 65

  • APPROX.

13 DATA BY REMARKS NORMAL POST ACC!ll NORMAL POST ACCID NORMAL POST ACC!D 8' J-3 12 2121' 11 6" ZS 20 RNg-14 3l22A-SW A CONTROL 10 q ROh! 8 ROh! !FT 4462-HR-SW ROh-l OSP-661 ([l""'--,xxH"'E'""'-1c:77A---:D::::G,--, ~ GENERATOR 7 6 ~ M -/4> L TSC 7 ([l 4462 COi FT 4462 !Pl(44 76A-HR-SW.._y'3/4' l'A' COOLER .. 8' F a* RNg-15 _,,, *.---- ROp-49 / 3!04A-SW 3l31A-SW 155X 2' l!J / ROi-22 3!1'lA-SW 20'

ROh, IPX4455A-HR-SW v~l

£lQ!:ci__,, 3138A-SW 2' m T II Px3/4~ 3/4 4 -© A-NC COMPONENT COOLING HEAT EXCHANGER 'A' 0 REMOVABLE SP MRF-22144,.. 2' 3133-SW ~-------, ECR-70724 \13100-sw u SET AT ,l;; 65 PS!G ~ 'N OJ I Cl UJ c,:r f£> 2" 2' MRF-22144 3141-SW -I DG "A' HI LUBE OIL/HI WATER JACKET TEMPERATURE LOGIC SEE GA! OWG D-802-014, SHT 5 -611 cc \ SET -A~T 7Al, \fil:l.i::.liL 64 P!SG 3!45A-SW 4' RNh-15 3124A-SW 24' 'l 7 20" @CD ~L fco~ L_<f>rsc ROhl NC ~-- H !--'-r-- A 01 20' 155X CD FE 4460 2' ROh-3 ~ ~TI' VENT 1:::-111~-j 6' l 241x20 1 5 COUPLING RNm-7 (3 REQ'Ol ] __ 7 SW DISCI "A' \ ROi-21 3130A-SW 8-2 -222: SHT.2 4 RETURN TO SW POND 3 2 1 A B C D E F LOOP 'A' -221 >l::J'~)-{~--',,1i..J-' HVAC CHILLER 1 (GA! OWG B-208-11219 ROh-1 0-10 o0 -84! ~ SW ~N (8 REO'Dl HYDROSTATIC TEST TEMP.60" 10 125 95 165 'l5 (1% 210 RJS 9 16 150 20 150 <1% 25 ccs 8 16 95 20 214 (1% 25 ccs 7 16 124 20 130 25 WTW LRC 6 65 124 65 130 82 WTW LRC 5 65 95 65 95 82 CCS NOTE 3 PSIG F PSIG F DURATION HYDR BY CHO REMARK N H UPSET DESIGN DATA 16' F-14 -222, SHT.2 6' RNn-55 ___.,.,- 3!28A-SW RN -16 6' RNn-55 3l26A-SW CHILLED WATER 0-302-841 LOC C-9 ROh-1 13118-SW Tl/ !PX4465A-HR-SW3/4, '3/4' STATION DRAINAGE E-911-106 LOG H-G r? v~ XHX-!A-VU HVAC SYSTEM MECH. WATER CHILLER COND 'A' ROh-1 13!1'l-SW 0-7 <:§] vu ~i.--------1 ROh-3 VENT ~ 1'

  • I

~--,-<()

HVAC CHILLER I C CONTROL I (GAi DWG B-208-109 SHT VUl1J3 & VU04) j RNn-55 RO -1 13121-SW HVAC SYSTEM MECHANICAL WATER CHILLER COND 'C' 3128C-SW "-,,_".----~----; RNg-16 1--E:l '3/4" / CHILLED WATER D-302-841 LOC 0-6 "s"'T""A,;,TI;;;O:;:;N--;D:;,R;-;:A"lN:;;;A~GE;;- E~!l-106 LDC H-8, 31280-SW ' "',m 10' 15' 20' ROh-1 IPX4495B-HR-SW MRF-21746 31'l5A-SW ap SP,., <i't ~"' *~ J '.irne-:::Tt '-+--+-- OJ ROh-1 l' !FT4463-LR-SW FB 4463 LO 3/4' 6' AT 70 PS!G 6' l-------j)""'-, MRF-21746 ~:.!§_ 3196-SW 31298-SW 3' 4 >---'-------------, - __Jj;r9-;,2d!t~ MRF-21746 / 31'!7-SW /

NOTES, I. ALL PIPING TO BE LINE SPEC 152N, EXCEPT AS NOTED.
3. TEMP CORRESPONDING TO PERTINENT HEAT EXCHANGER OUTLET.
5. Ai_L STATUS LIGHT INDICATE BOTH OPEN AND CLOSED POSITIONS.
6.
  • DENOTES MISSION DUO CHECK OR EQUAL.

1!. XVC03130 A/8 MAY NOT PROVIDE ADEIJUATE ISOLATION FOR USE AS A BOUNDARY DURING SYSTEM DRAINING. REFERENCE NCN5063 D!SP.*4 THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE INITIATED OR PERFORMED WJTHOUT PRIOR DOCUMENTATION AND WRITTEN APPROVAL FSAR FIGURE 9.2-2 SH. 1 PIPING SOUTH CAROLINA ELECTRIC ~ GAS COMPAIIY VIRGIL C. SUMMER NUCLEAR STATION SYSTEM FLOW DIAGRAM SERVICE WATER COOLING G H J A - TR,>JN OUTSIDE RB i=+==i==i===========i==r==i-<C,§.-1'°---D~E~S~IG~N~EN~G~INreEEERRll~NGG--7 K l-+---jf---j--------*---r-,-111~NY.WW'lffl' V.¢.SUMMER NUCI.EAA STATION JENKINSVJLLE,S.C. MADE CHECKED LE APPROVAL JNC PAH '* MGC D 1/6/00 JNC REVISED PER ECR-71215 PAH MGC LE NO, DATE SY REVISION D-3O2-222 1 0 DRAW lf.lG NUM8ER SHT, NIJMBER m,,-y RN 09-002 January 2010}}