KP-NRC-2204-007 Kairos Power LLC www.kairospower.com 707 W Tower Ave, Suite A 5201 Hawking Dr SE, Unit A 2115 Rexford Rd, Suite 325 Alameda, CA 94501 Albuquerque, NM 87106 Charlotte, NC 28211 April 15, 2022 Docket No. 50-7513 US Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Kairos Power LLC Presentation Materials for Kairos Power Briefing to the Advisory Committee on Reactor Safeguards, Kairos Power Subcommittee, on Design Overview for the Hermes Non-Power Reactor This letter transmits presentation slides for the April 21, 2022, briefing to the Advisory Committee for Reactor Safeguards (ACRS), Kairos Power Subcommittee. At the meeting, Kairos Power will provide an overview of the design of the Hermes non-power test reactor which is currently under NRC staff review for a construction permit. This briefing is intended to provide a high level overview of the Hermes design prior to the ACRS review of the Hermes PSAR.
The content of this information is non-proprietary; Kairos Power authorizes the Nuclear Regulatory Commission to reproduce and distribute the submitted content, as necessary, to support the conduct of their regulatory responsibilities.
If you have any questions or need additional information, please contact Drew Peebles at peebles@kairospower.com or (704) 275-5388, or Darrell Gardner at gardner@kairospower.com or (704) 769-1226.
Sincerely, Peter Hastings, PE Vice President, Regulatory Affairs and Quality
KP-NRC-2204-007 Page 2
Enclosures:
- 1) Presentation Slides for the April 21, 2022, ACRS Kairos Power Subcommittee Briefing xc (w/enclosure):
William Kennedy, Acting Chief, NRR Advanced Reactor Licensing Branch Benjamin Beasley, Project Manager, NRR Advanced Reactor Licensing Branch Weidong Wang, Senior Staff Engineer, Advisory Committee for Reactor Safeguards
Presentation Slides for the April 21, 2022 ACRS Kairos Power Subcommittee Briefing
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
PRESENTATION FOR THE ADVISORY COMMITTEE ON REACTOR SAFEGUARDS, KAIROS POWER SUBCOMMITTEE APRIL 21, 2022 Hermes Design Overview 1
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Kairos Powers mission is to enable the worlds transition to clean energy, with the ultimate goal of dramatically improving peoples quality of life while protecting the environment.
In order to achieve this mission, we must prioritize our efforts to focus on a clean energy technology that is affordableand safe.
2
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Agenda
- Introduction
- Fuel/Core Design
- Reactor Vessel and Internals
- Heat Transport & Pebble Handling and Storage
- Structures
- I&C and Electrical
- Safety Case 3
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Introduction DREW PEEBLES - LICENSING MANAGER, SAFETY 4
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Introducing Kairos Power
- Nuclear energy engineering, design and manufacturing company singularly focused on the commercialization of the fluoride salt-cooled high-temperature reactor (FHR).
Founded in 2016 Current Staffing:
269 Employees (and growing)
~90% Engineering Staff
- Private funding commitment to engineering design and licensing program and physical demonstration through nuclear and non-nuclear technology development program.
- Schedule driven by the goal for U.S. commercial demonstration by 2030 (or earlier) to enable rapid deployment in 2030s.
- Cost targets set to be competitive with natural gas in the U.S.
electricity market.
5 Kairos Power Headquarters Kairos Power Team
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Kairos Power Design Approach 6
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
- What?
A low power demonstration reactor that will prove Kairos Powers capability to deliver low-cost nuclear heat
- Why?
Cost: Establish competitive cost through iterative learning cycles Supply Chain: Advance the supply chain for KP-FHR specialized components and materials while vertical integrating critical systems Design / Test: Deliberate and incremental risk reduction Licensing Approach: NRC will license Hermes as a non-power reactor and facilitate licensing certainty for KP-FHR Operations: Provide a complete demonstration of nuclear functions including reactor physics, fuel and structural materials irradiation, and radiological controls OperationsHermes will ultimately demonstrate the U.S. aptitude to license an advanced reactor in a timely manner Kairos Power Hermes Rea ctor Overvie w Kairos Power Hermes Reactor OverviewETU / Hermes KP
- X / U-FacilityFacility 7
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Fuel/Core Design BRANDON HAUGH - SR. DIRECTOR, MODELING & SIMULATION NADER SATVAT - MANAGER, REACTOR CORE DESIGN 8
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
KP-FHR Uses TRISO Fuel in Pebble Form
- Fuel Pebble (3 Regions):
Innermost portion is a low-density carbon matrix core Fuel annulus - Tri-structural isotropic (TRISO)-
coated fuel particles embedded in a carbon matrix Fuel-free carbon matrix shell
- Fuel qualification leverages U.S. DOE Advanced Gas Reactor program
- Core design is a pebble bed concept within a graphite reflector Pebbles are positively buoyant in Flibe Mixture of fuel and moderator pebbles operates with optimal moderation 9
4.0-cm diameter, annular fuel pebble is the same size as a ping-pong ball
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Hermes Core Design 10 Power:
35 MWth Fuel Cycle:
190 days average residence time 4-6 passes Discharge burnup 6-8% FIMA Safety Parameters:
Overall negative temperature reactivity coefficients Negative fuel and moderator temperature reactivity coefficients Negative coolant temperature, and void coefficients Method for Calculation:
High-fidelity Serpent 2 and KPACS (Serpent 2/Shuffling)
Power Profile:
Average Power per pebble = ~1000 W/pebble Pebble Peaking factor ~2 Coolant:
Li-7 enrichment level and carbon to heavy metal atom ratio aligned to provide desired temperature reactivity coefficient
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Reactor Control 11 Diversity:
Reactivity Control System (RCS)
Reactivity Shutdown System (RSS)
Analysis:
Compensate power defect, full xenon decay, operational excess reactivity, and B4C depletion Single, most reactive rod failure SDM to of 0.99 Sources of Operational Excess Reactivity:
Core composition Compensate change power levels or manage other transients Method for Calculation:
High-fidelity coupling tool, KPATH (Serpent 2/Star-CCM+)
Other notes:
Drive mechanism sets limit on withdrawal rate (rate of reactivity insertion)
KP-FHR has a strong (and prompt) Doppler feedback to reduce regular use of the RCS
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Core Design Methodology 12 Safety Tools Nuclear Data Support Tools
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Representative Information 13 1x108 - 5x1014 n/cm2.s 0 - 26 W/cm3 Fast Flux Thermal Flux 550-700 °C Flibe T Surface T Power 550-700 °C
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Reactor Vessel and Internals ODED DORON - SR. DIRECTOR, REACTOR SYSTEM DESIGN 14
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Reactor Vessel and Internals Overview 15
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Hermes Coolant Circulation Path Overview 16
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Hermes Head Layout 17
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Hermes Reactivity Control and Shutdown System 18 Hermes Core Layout 3x inbed shutdown elements 4x excore control elements Drive Mechanism Motor driven sheave to position element Release Mechanism
- 1: Electromagnetic clutch
- 2: Motor isolation
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
19 Control Element Shutdown Element Control Element Segmented Annular Design Individual Capsules Argon fill Absorber: B4C Cladding: SS-316H Shutdown Element Cruciform Design Inner Cladding contains absorber Argon fill Absorber: B4C Cladding: SS-316H
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Heat Transport & Pebble Handling and Storage NICOLAS ZWEIBAUM - DIRECTOR, SALT SYSTEMS DESIGN 20
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Primary Heat Transport System (PHTS) - Overview
- The Primary Heat Transport System (PHTS) is responsible for transporting heat from the reactor to the ultimate heat sink (environmental air) during power operation and during normal shutdown
- The PHTS operates near atmospheric pressure and does not provide a safety-related heat removal function (see Decay Heat Removal System)
- The safety-related hot leg anti-siphon feature is performed by the Primary Salt Pump downward-facing inlet (the pump being supported in position by the Reactor Vessel upper head)
- Additionally, the PHTS provides for the following functions:
Contain and direct the reactor coolant flow between the reactor vessel and the heat rejection subsystem Manage thermal transients (overall thermal balance) occurring as part of normal operations Ensure minimum acceptable temperatures in the PHTS through make-up heating as necessary Provide capability to drain the PHTS to reduce parasitic heat loss during over-cooling transients Provide for in-service inspection, maintenance, and replacement activities 21
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
PHTS - System Makeup
- Reactor Coolant Flibe
- Primary Salt Pump (PSP)
Variable speed, cartridge style pump located on the reactor vessel head; inlet extends downwards through the Reactor Coolant free surface
- Heat Rejection Subsystem (HRS)
Provides for heat transfer from the reactor coolant to the atmosphere Consists of the heat rejection radiator, heat rejection blower, and associated ducting and thermal management
- Primary Loop Piping
- Primary Loop Thermal Management Provides non-nuclear heating and insulation to the PHTS as needed for various operations 22
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
PHTS - High Level Description 23 Parameter Value Thermal duty 35 MWth Number of HRRs 1
Number of hot legs 1
Number of cold legs 2
Primary loop line size 8-12 in nominal pipe size HRR inlet coolant temperature 600-650°C HRR outlet coolant temperature 550°C Nominal flow rate 210 kg/s PHTS design pressure 525 kPa(g)
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Decay Heat Removal System (DHRS) - Overview
Purpose:
Vessel protection during postulated events for which the primary heat transport system (PHTS) is unavailable Operation: In-vessel natural circulation coupled to a passive water-based, ex-vessel system via thermal radiation and convection Continuous direct boil-off when estimated decay loads exceed parasitic losses Shutoff and isolated for low power levels (heat removal via parasitic losses only)
No change of state on reactor event initiation Load: Removal rate is a function of vessel temperature Due to physics of thermal radiation heat transfer 24
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
DHRS - Process Flow Diagram
- DHRS does not directly interact with the primary coolant
- No change of state on onset of postulated events Always-on operation for set power levels
- Parallel and independent cooling pathways Four independent cooling loops Only three loops required to meet cooling demand
- Dual-walled for leak prevention and detection Continued heat removal in the presence of a leak
- Active component (isolation valve) failures do not introduce failures in heat removal Isolation valve fails in place (an operating system continues to operate)
Float valve nominally fails open 25 Feedwater
- Constricted to limit drain rate Steam Return Isolation Valve Separator Storage Tank Leak Barrier Relief Reactor Cavity
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
DHRS - Operation 26Core (low/
No Power)
Normal Operation (DHRS deactivated)
(DHRS deactivated)
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
DHRS - Operation 27Core (High Power)
Power)Normal Operation Normal Operation
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
DHRS - Operation 28Reactor trip tripTransient Event (unrecoverable loss of PHTS, loss of electrical power, loss of feedwater) loss of feedwater)
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Pebble Handling and Storage System (PHSS) - Overview
- Responsible for handling of fuel in Hermes, from initial on-site receipt, in-process circulation, and final on-site storage
- Major components of the system:
Pebble Extraction Machine (PEM): single screw for removing pebbles from molten salt Pebble Inspection System: performs flaw detection and burn-up measurement of removed pebbles Processing System: sorts pebbles into appropriate buffer storage channel based on pebble type Insertion System: stepper wheel feeder mechanism that inserts pebbles into the reactor via an in-vessel insertion line Storage System Canister: stores ~2,000 damaged or spent fuel pebbles in a non-critical configuration Storage Cooling Area: passively cooled, in-building storage area for spent fuel canisters New Pebble System: stores fresh fuel and prepares fuel for circulation via a high-temperature bakeout 29
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
PHSS - Layout and Pebble Path 30 Recirculate Fuel New Pebble Other Spent Fuel Moderator
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Structures BRIAN SONG - MANAGER, CIVIL STRUCTURES 31
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Reactor Building Layout 32
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Meteorological Loads
- Design considers rain, snow, wind, tornado and wind-borne missiles for site.
- Safety-related reactor building designed without crediting non-safety-related exterior shell for protection from snow, wind, rain, and missile loads.
- Exterior shell of safety-related reactor building designed with concrete thickness to protect safety-related structures, systems, and components (SSCs) from high-wind missiles, including debris from potential damage of non-safety-related reactor building.
33
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Flood loads
- Safety-related SSCs will be protected from internal flood (spray and accumulation) with shields, curbs, drains, etc.
- Safety-related Reactor Building protects safety-related SSCs from credible external flood.
34
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Seismic Loads
- Using risk-informed performance-based insights to define seismic design criteria (i.e. ASCE 43-19, SDC 3)
Seismic design basis earthquake based on site-specific seismic hazard considering other recent and nearby seismic hazard analyses and site-specific geotechnical characteristics.
- Safety-related Reactor Building incorporates spring/dashpot seismic isolation system, which lowers seismic demands on safety-related reactor building and safety-related SSCs in both horizontal and vertical directions.
- Moat and flex connections accommodate displacements of isolated safety-related reactor building.
- Safety-related portion of the Reactor Building will be represented by a three-dimensional finite-element model developed in accordance with Chapter 3 of ASCE 4-16.
35
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Instrumentation & Controls and Electrical Systems ANTHONIE CILLIERS - DIRECTOR, INSTRUMENTATION, CONTROLS AND ELECTRICAL 36
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Instrumentation & Controls and Electrical System Design Relies on the Following Systems 37 Reactor Protection System (RPS)
Safety Hazard Intervention and EventLimiting Defense Plant Control System(PCS)
System with OperationalReliability and Diagnostics IntelligentHealthMonitoring Health Evaluation and Analysis in Real-Time Semi-autonomouscontrol room (MCR)
Semi-autonomousIndustrial GradeHMI Technology Electrical supply Basic Ohm Law Triangle(V = I.R)
Robust Inherent Safety Plant protection and control
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Plant Protection, Control, and Health Monitoring Operating Envelopes 38 RPS PCS Health Monitoring Minimum dynamic operating envelope
- margin based on model fidelity Static operating envelope protecting nuclear and non-nuclear equipment integrity - non-safety-related equipment Maximum allowed static operating envelope -taking full advantage of safety margin, protecting nuclear safety related equipment Safety Margin -based on fuel temperature limitations, excess available reactivity and maintaining core geometry integrity
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
39 Instrumentation and Controls Architecture
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
40Instrumentation and Controls Architecture Instrumentation and Controls Architecture
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
41 Electrical Architecture
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Safety Case JORDAN HAGAMAN - DIRECTOR, RELIABILITY ENGINEERING 42
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Safety Case Approach
- Deterministic approach consistent with NUREG 1537, Chapter 13
- To demonstrate compliance with regulatory dose limits, a Maximum Hypothetical Accident (MHA) that bounds the Chapter 13 postulated events is analyzed for dose consequences MHA not physical MHA includes conservatisms that maximize source term MHA includes a postulated release of radionuclides
- To ensure that the postulated events are bounded by the MHA:
List of postulated events is comprehensive to ensure that any event initiator with the potential for radiological consequences has been considered Initiating events and scenarios are categorized, so that a limiting case for each group can be qualitatively described in CPA (quantitative results will be provided with OLA)
Acceptance criteria are provided for the important figures of merit in each postulated event group to ensure the potential consequences of that event group remain bounded by the MHA as the design progresses Prevention of an event initiator is justified in PSAR 43
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
List of Events Postulated
- MHA - Hypothetical heat-up with conservative radionuclide transport
- Insertion of Excess Reactivity
- Salt Spills
- Loss of Forced Circulation
- Mishandling or Malfunction of Pebble Handling and Storage Systems
- Radioactive Release from a Subsystem or Component
- General challenges to Normal Operation
- Internal and External Hazard Events 44
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Maximum Hypothetical Accident
- Hypothetical heat-up event with conservative assumptions meant to drive radionuclide release:
Pre-transient diffusion of radionuclides from the fuel in the reactor core is neglected Prescribed hypothetical temperature histories are applied to the transient The gas space is not credited for confinement of the radionuclides that release from the Flibe-free surface Conservative, unfiltered, ground level releases Conservative tritium modeling A bounding vessel void fraction is assumed to facilitate the release of low volatility species in the vessel via bubble burst.
45 Location and Duration Whole Body Dose (rem)
Thyroid Dose (rem) 10 CFR 100 Limit MHA Result 10 CFR 100 Limit MHA Result Exclusion Area Boundary (First 2 hrs at 250m) 25 0.227 300 0.235 Low Population Zone (30 days at 800m) 25 0.059 300 0.081
Copyright © 2022 Kairos Power LLC. All Rights Reserved.
No Reproduction or Distribution Without Express Written Permission of Kairos Power LLC.
Postulated Events
- The postulated event methods are provided in KP-TR-018, Postulated Event Analysis Methodology (incorporated by reference in PSAR Ch. 13)
- The phenomena for each postulated event group that have the potential to increase dose consequence are identified as figures of merit
- Acceptance criteria are defined for the figures of merit that will ensure that the limiting event in each postulated event group is bounded by the MHA
- Validation and detailed final analyses of the postulated event groups will be performed for the operating license application 46