ML21305A243
Text
OLD4 CUTLINE C
Ol o
u 00
- C a, 0 o,+-
'U 0
.o
'o 0-v, U) ' z r-- sr N rt')o""
srw L II I"'-
Q) 0:: "' (/)
w... ::J f---
VlZO
<( C)<(
0:: OU E
FOLD D
C FOLD B
4NPG "I S lze I \\709L£\\7 A 480V. MCC BUS SECT "1F" 8----------
c----------
1 l l 52*/F-35(;- -f--(
42-IF*35 OPEN 4_9JF-35 0
~
,.)
Ol.
L I
SPF I
A C
MPF35
\\
/
Mi t
TJIRff LIN[ [)!AGRAM I
5PF 2A 480/J20V 42-JF*35 CLOS VALVE NO.
8992 2
3 4
5 C'
0:
OL AUX RELAY OPEN CLOS~
INPIC AT I ON MONITOR LIGHT CONTACT.
(ALL VIILVES AUTO OPEN ON
- oR VALVl"S "}00/A.
EXCEPT 50?3A, 6
190035, "JOO/A,J SPRAY ACTUATION I y 9001 B -
1 REF. DWG # /3
,. FCJ~ V,4{ VE §_J~c ONLr..JLL OTI/E,f Vi'S:,.
~Xi _ MPf35 I
I 90018,Stt 81.0W P05 703 S T3 IB (SEE IJOTE I)
POS 70.J:
,' T-3 l(lb)i7 (SEE NOTE 2)
B 4--P05703.
~
fS;;Nor;J)
- - - - - 7 A-T01
,:: %"\\
- l: Al wA3 : ~
MPF3Ei RNS¢B Cl MPF35 t &
1,, 7
"< 1 o:1 1 /XI
/i:I o
11"0-/
f!XI
- 2X I
} '>s ~
1"
- 1 "'1
"-i"' ;._
I
/Ji
- 1 1x1---<r8 K643 SPF ~2x1-,g_CNC 5
- l_s I\\
L. - - ~2_tl4-'
SPF c~r~NCS I
111
~ 0\\ ~
4!JJ-if-3S 42*/F-35 f640*L 4?-IF35 ~ ~ ~
49*Jf-35 OL *,;
DL Bt CS/OPEi\\/
CI CS/CWSl:.
t A
CNCS
.J'fl.CNCS
'-' i
/
/):I i
~
1 RN5(M
~'
(,40*!
1 *l-5 Pf.
t:
z C
K643
~
42 ff*35 cc
/
640-2]
42-/f *35 4 oPt:N s_P_F,,__ __ 1 RNstiA CLos~ T
~
~3"---/----~
~-_.,
~
42-!F-:35 CLOS£ 49*1f*35,
Ol RNS¢B 42*ff*3S OPeA/
5A
}3 9
21 17 42-1(-35 7..,1 '"I ~ 1.,1 CL05l. "
~I ~ ;{_I }
Ir)
Ir) Iii 14
/0 ZZ
/8 2Nolc1Ax2-F 1
( All MOV:S- £XC£PT 9003A If 900313)
X2t--__ _,._ __________
~
I,--MPG65 I
CH(5 Ul'F35 MPF35 8THIIO
.3 15 5A
- 1P0S71/
f'OS7" 3I:
15,Tlt<5~ ?,1111;5.f MPG5S MPF3S MPF3f9 JC--- 3R 3~
.JR
}cM:s CNC5 6
6 L'
u*,
(tVCS,l CtVC,1 CONTAINMENTSPR~YT£5T/NTLK M
FOR VtVS, 899,{L/111} k '}00//1,8 ONLY. ~f. DWG,><I~
I?
MPF35 12 BTHIIO MPH?-0 RNSTA rES---<>
POS 719 14[
MPH40 fb--ORNSTA G
R G
R TRAIN A CKT OOORA.34-SR; K
-xz-0:,...__...,
T C#C5 7
TRAIN 8 CKT 0001t834 l?OVAC CONTROL SCHEMATIC 8992 SPRAY ADDITIVE TANK OUTLET CIRCUIT No F3SPOO CONTAINMENT SPRAY 5YST£J.A UOVs S!lv!ILAI? £xcePT A5 SHOWN IN liiBLe DESCRIPTION ENGINEER VALVE POSITION SWJTCH-(POS)
CNT. ISOL.PH A ALARM CKT.NO.
CIRCUITCIRCUIT BUS NORMAL SAFETY MONITOR INTERLOCK STEM MTD INTERLOCK CLOSE MOTOR QC BYPASS OVER BK R NO NO SECT POSIT JON VI T AL POS LIGHT 1--~~~'-'r---<"-'-~-=s---'+'-'~~'-'+---< B YP fiSS 1---~-----1 FUNCTION NO. rnMTAr.TCONT.VALVE NO.REF POS NO. CONT.VALVE NO.REF c6~Tk~T DEVICE CONTACT CURRENT SPRAY ADDITIVE TANK OUTLET 52-IF-35 F35POO IF OPEN P
703 12 I
CIAX2-F I-H-2 NO Al4408DF 8994A SPRAY ADD.TK.OUT.ISOL.LINE I 52-IG-55 G55POO IG CLOSED p
71 I I 2 CIAXZ-G I-H-2 NO Al4308DG 8994B SPRAY ADD. TK. OUT. ISOL. LINE 2 52-IH-40 H40POO I H CLOSED p
9003A RHR PPS TO SPRAY RING HDRS.1&3 52-IG-48 G48POO I G CLOSED 90038 RHR PPS TO SPRAY RING HDRS.2&4 52-IH-6 H06POO I H CLOSED 9001A SPRAY PPII DISCH ISOL VALVE 52-IG-21 G21POO IG CLOSED p
9001B SPRAY PP12 DISCH ISOL VALVE 52-IH-II HI IPOO IH CLOSED p
A--r' MPG48 IX£ A ~?f{IPH6 JX5
¢ BTK3 yMPG58
'7 BTK"{-
.-- 1x5 7 I 9 I 2 727 16 732 16 741 12 757 I 2 r
1J;s
.1.. POSG26 SEE J./OTE 4
.9TOP/8.98JJ!
I
/,MPG5/3 1
MPH/2 POS c.3~
SEE NOTe 4 g, TO?/ 8:JbU!
L._1.1/4
?BfK3 IX~
PNARB +
1/{6 RNA!i-8 }--IX,:, 7.MASA Ari_ ~67'1-J_ A_i POS6G'!X BIT CL/870/ B/T CL/8702.
RNASB '('--IX/ --6 F(JIASA IX/
2 Ix/
\\' M?l/12
/Xe,
'I i3TK+
IX(.
8NAR8?
I XG RNARA ~
IXG R.NASA O--/)l,6T_RNAS8 P11POS669X DA_ rosi;,74-EITCL/8702 EIT CL/8701 RNA SA }--1 XI __J, M4S8
/;/.I IX!
2 MARB 9 SPGI RNAR8?
42-/6-48 8 ~t CNCS oFeN l Bl SP!/ I MARA 9 42-Jl/*6
!XI NOT USED B
42-*/6*4-6 3
JCS/OPEN c~
1 ~cllcs SP6 csjoPeN le, -_i cf/Cs NOT USED
- 1
- . 4-2-IH-IJ 3
A~CS/OPEN c-I Ci/CS
.SPI-I 13 8700A 8 13 8700B 8 A
> I MP62I IX I SPG l IX I RN5¢B y--
h4/-3 l'l-1 B
42-/G-2/ I I CS/Ol'eN M2 2K6/7 AT r2T CNCS /
J 611-4 6PG o--
I RNS$B C ___.., I 900/A 0/'e/JIIJG CIR.C/1/T I/JT1<._LOCKS 16 16
'100/8 SIMILAR. EXcEPT AS 5/loW!V IN TABL£ ABO/IE
.::l003A OPENING CIRCUIT INTE/i?LOCKS 90038 OPENING CIRCUIT INT£RL()CKS I
I I
CIAX-H 9-H-10 NO Al4208DH Al4308DG Al4208DH CIAX2-G 3-H-4 NO Al4308DG CIAX-H 11-H-12 NOAl4308DH I
6 CLOSE OP(N CONTACTS
---S>--
7 POSITION REMARKS CLOS[\\ NEUT OPEN A
X X
SPAR.
1-----+-+--+--I---*- --~~*-~--1 8
X 'THIS 0WG
---Sr--
---l>--
C X
THIS Dws
---Sf--
D X
X
.SPARE.
42*/F-35 42 IG-21 42-IG-481t cs
)
cs
)
cs 42*/G*55 CONTROL SWITCH-cs 42*/H*(;,*
42 IH-1/
4Z*/H-40 cs
)
cs
) cs
'JSt:.D AT LOCATION CNCS SPRING RETURN lo NEUTRAL
- 42.*IG*48/CS 8i 42*/H-G/cs TO BE MAINTAINeD CONTACT 8.- 'NAME.PLATES 70 READ "CLOSE-STOP* OPeN ".
CONTACT5 VAL VE POSITION FULL OPEN FULi..
CLOSED FUNCTION I FUNCTION CONTACTS I T08\\0JNTAC1S'l10!.
---sr-I 9 I I SEE TABLE
') ! SPARE
--,f--
Z 'JO 21 SPARE JO SPARE 1-=:;;:==--T3a111111-~-------~;;;t--isTi'.G;RRf!EEONILJGHT Ii SPARE t=~=]4~12;t==E~~~~f~~f~t*84}210P']E'.N:NJLJ:1BJM1T 12 SEE TABLE
--,f--
5 13 5 BYPASS INTLK. /3 SEE TABLE
---lf--
6 kt",
---r--);..;.;,;-~,
6;iSPSP,ARE
)4 SEE TABLE C'
a' 8
0'
---lf--
7 15:1--~----*--1117! SPARE.
IS RED LIGHT
---s>--
8 16 8iSEE NOTES 3 16 SEE TABLE TYPICAL VALVE P05/TION 5WIT(H CONTACT DfV[LOPME,'-JT ACTUAL SETPOINTS ARE IN l°IM5 CONTAINMENT SPRAY SIGNAL SSPS TEST INTLK ISEE NOTE 81 MOTOR LOC. NO. DEVICE LOCATION CONTACT TRAIN A TRAIN B CONTACT CKT NO. CONTACT CKT NO.
Mp F 3 51--!"\\\\!'
"c:e4 ~---4-,;R,,,.N;;;S~IIJ,,,A-+k!T ",!-\\R"4¥+
01-<-"->-~-?H K643 RNS0B TB640 l-<>-2 MPG 55 K644 RNS/11B TB64 I l-<>-2 14 OOORB34 MPH 40 K644 RNS0A TB64 I l-<>-2 14 OOORA34 MPG 48 MPH 6 MPG 2 I K644&2K6 I 7 RNSIIJB 1B641 3-<>-<>-4 14 OOORB35 MPH I I K644&2K6 I 7 RNSIIJA 1B641 3-<f-<f---4 14 OOORA35
}
)
)
KEY DWG.
SECTION 4
9 10 TABLE OF DEVICES DEVICE NO.
FUNCTION RATING TYPE MFR. CAT/DWG*
REMARKS 42-IF-35 480V AC MOTOR STARTER 42-IG-21,-46,-55 REVERSIBLE, SIZE I 42-IH-6,-11,-40 49-IF-35 MOTOR OVERLOAD RELAY 49-IG-21,-48,-55 49-IH-6,-11,-40 WE CORP -
49X*IF*35 MOTOR OVERLOAD AUX. RELAY WE CORP 49X*IG*21,*48,*55 49X*IH-6,*l l,-40 52-IF-35 52-1 G-21, -48, -55 52-IH-6,-11,-40 CIAX-F,H CIAX2-G FCV-POS-K643,K644 2K617 TS 480V AC AIR CIRCUIT BREAKER CNT ISOL PH.A AUX RELAY MOTOR OC BYPASS FLOW CONTROL VALVE FCV POSITION SWITCH SPRAY ACTUATION AUX. RELAY K617/SIS AUX. TIMING RELAY TORQUE SWITCH POS674X,669X VALVE POSITION SW AUX. RELAY LEG£ND:
REF DWG
- l,2,3 REF DWG 11: I, 2, 3 C I 5 I (101(111 I I I I 8
- Mov's Pl{OVIDE.D W/Tlf /:'/ELD INST,IJLLE.b ql.lJCJ<.T!ST"C~.Bt.l ASSEMBLIE.S. SE! APPL/C,1/BL(./)l/;GRAl--1 OF CONNc.t.T/ON~.
EQUIPMENT LOCATION NUMBERS SPF 480V MOTOR CONTROL CENTER, BUS SECTION IF MPF35-MOTOR OPERATED VALVE 8992 CNCS CONTROL BOARD, CONTAINMENT SPRAY RNS0A -
RACK NUCLEAR SAFEGUARD, OUTPUT TRAIN A RNARB-RACK NUCLEAR AUXILIARY RELAY CUB. B BTK4 TERMINAL BOX AREA K NO.
4 RNSTA -
RACK NUCLEAR SAFEGUARD TEST TRAIN A NOTES PART OF MOTOR STARTER PART OF MOTOR STARTER CLOSES ON PH A ISOL &
SIS ACTUATION SEE TABLE FOR VALVE NO'S SEE TABLE FOR SW NO'S I -
SWITCH OPENS ON MECHANICAL TORQUE DURING OPENING CYCLE C 181.
2-SWITCH OPENS ON MECHANICAL TORQUE DURING CLOSING CYCLE OR FULLY CLOSED VALVE C I 7 I.
3-FIELD TO INSTALL JUMPER FOR TORQUE SEATING 4-FOR VALVE 9003A-WIRE NO'S IX5 & IX6-FROM MPG58 TO BTK3 (VALVE 8982A POSITION SWITCH) ARE LISTED IN CKT NO.G58P07. SIMILAR FOR VALVE 9003B EXCEPT FROM MPHl2 TO BTK~ (VALVE 8982B POSITION SWITCH) AND LISTED IN CKT. NO. Hl2P07.
5-STEM MOUNTED POSITION SW.
ADDED BY WESTINGHOUSE PER
@ 501BIBO 6-7-
SH.166 & 167, REC.*663193-166, 167.
8-PERMISSIVE INTLKS FOR SSPS SLAVE RELAY K64S TESTING.
VALVES MUST BE CLOSED FOR SSPS TEST. SEE REF
- 17.
REFERENCE.
DRAWINGS l *S1NGLE LINE METER 1 RELAY DIAGRAM, 480 V SYSTEM Bus 5Ecr. IF
!~
J J I J
l l l ! l :~ ~:
4.-DEsCRIPT/ON OF ELECT 5CHEMATIC DtAG-5, 5YMl30LS, ( CKT DE510NATIONS 5* Eau1PMENT LoCATJON N-.1M8ER Lis r Dwr:, # 43 79 IG 437542 437543 0.50003
/01900 6.-PIPING.SCHEMATIC CONTAINMENT 5PRAY 5YSTElvl
/020/2 7.*[NSTRUMENT SCHEMATIC fLOW INSTRUMENT 5YSTEMS 102032 li*SCHEMAr1c D1A6-Rts1DUAL HEAT REMOVAL FLow Co,vrRoL VALVES l 437592 9.-
t
{ *SIJFtTY fNJeCTION SY.STEM MoTO,f 01'£RATE!) //IIL//c5 437605 JO.* FuNCT!DNDIA~RAi'IS REc.# 663/35 JI* SCHEM [)JAG, SSPS 0/JTP/JT RELAYS, TRAIN A, TRAIN 8 iiW0S 501869, 503088 12-ScHEMATIC DIAG. MAIN ANNUNCIATOR SH. /GJ 17-DWG,, 50113b, 7 13
\\
\\
MONITOR l!GHT 8ox A, D
-D.WG;,4,57t:,9t., 9
- 14.
t i 4KV AVTtJ YF/l.. Bt!S GJ/. l)~,437624,437627
/5.
SCll£MAT/C D/AG S/S MO v:S DW<E,, 437-,0tp
- 16. SOLID STATE PROTECTION SYS. SFGD. TEST MANUAL, REC.
VALVE N95 8992, 899-fA, 8994E, 900/A, 900/B,9003A,9.;:i3.B I 7-SCHcMA77C Dl/i{j. 3AFE$UJIRO TtFST Cl/8 7ER!-1 BU<. TRAIN ;,i * /Jfltj. 498045
- 18. SCJIEHATIC P/Af', 5/lFGCjUARD Tt=ST OIB. 7cRM. BL,K TRAIN" f3'1 PWG, 4'78099 NUCLEAR SAFETY RELATED UNIT I
~
)-..
B C
P.G.&E. SYSTEM PHASE SEQUENCE A-C-B DATE 03-13-2019 REVISION DESCRIPTION ELECTRICAL SCHEMATIC DIAGRAM CONTAINMENT SPRAY SYSTEM MOTOR OPERATED VALVES DWG SCALE:
D..
ZNS4 R. E.
FXC2 I. V.
NIA P. E.
N/A I
I Revised Per DDN-2*1830 DIABLO CANYON POWER PLANT PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORNIA I
I BILL OF MATL:
SUPSDS:
SUPSD BY:
DRAWi NG SHEET PAGE REV 437604 I
O 23
~
FOLD FOLD z
0 z ST io
~ U)
C r--
OLD4
'"'