September 10, 2021 MEMORANDUM TO: Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM:
Ngola Otto, Project Manager /RA/
Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF AUGUST 5, 2021, PRE-SUBMITTAL MEETING WITH FRAMATOME AND THE U. S. NUCLEAR REGULATORY COMMISSION REGARDING TOPICAL REPORT EMF-2310, SUPPLEMENT 2 - SRP CHAPTER 15 NON-LOCAL METHODOLOGY FOR PRESSURIZED WATER REACTORS: BIASI CRITICAL HEAT FLUX CORRELATION DESIGN LIMIT FOR HTP FUEL (EPID L-2020-TOP-0052)
On August 5, 2021, the U.S. Nuclear Regulatory Commission (NRC) staff held an open teleconference meeting via Microsoft Teams with representatives from Framatome Inc.
(Framatome). The purpose of the meeting was for the NRC staff and Framatome representatives to discuss Topical Report (TR) EMF-2310, Supplement 2, SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors: Biasi Critical Heat Flux Correlation Design Limit for High Thermal Performance (HTP) Fuel. The meeting was noticed on July 21, 2021, and is available in the Agencywide Documents Access and Management System (ADAMS) Accession No. ML21202A083.
During the meeting, the Framatome representatives provided an overview, explained the range of applicability, critical heat flux correlation design limit description, and content of what would be submitted in the EMF-2310 supplement. The NRC staff asked the Framatome representatives about submitting the associated data prior to the submittal. The NRC staff and Framatome representative agreed to have a follow-up discussion regarding the feasibility and logistics of transmittal and review of the pre-submittal data to facilitate the review. There were no questions and/or comments from members of the public during the meeting. At the end of the meeting, the NRC staff and Framatome representatives discussed the next steps which included the planned TR submittal in February 2022, and a requested approval by August 2022.
A list of the attendees is enclosed. The Framatome presentation materials, including this meeting summary, can be found at ADAMS Package Accession No. ML21218A104.
Docket No. 99902041
Enclosure:
As stated
Enclosure List of Attendees PRE-SUBMITTAL MEETING BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND FRAMATOME INC. REGARDING TOPICAL REPORT EMF-2310, SUPPLEMENT 2 -
SRP CHAPTER 15 NON-LOCAL METHODOLOGY FOR PRESSURIZED WATER REACTORS: BIASI CRITICAL HEAT FLUX CORRELATION DESIGN LIMIT FOR HTP FUEL AUGUST 5, 2021 4:00 pm - 5:00 pm NAME ORGANIZATION John Adams Framatome Inc. (Framatome)
Morris Byram Framatome Marc Dziuba Framatome Greg Kessler Framatome Thomas Gardner Framatome Rick Williamson Framatome Joshua Kaizer U. S. Nuclear Regulatory Commission (NRC)
Robert Lukes NRC Ngola Otto NRC Joseph Messina NRC Ethan Deters NRC Tamara Stathes Exelon Lewis Wells Exelon Brain Mount Public David Bajumpaa Public Ruxandra Bobolea Public Jay Kabadi Public Taylor Adams Public
ML21218A104 (Package)
ML21218A107 (Meeting Summary)
ML21209A554 (Presentation - Non-Proprietary)
- via e-mail OFFICE NRR/DORL/LLPB/
PM*
NRR/DORL/LLPB/
LA*
NRR/DORL/LLPB/
BC*
NRR/DORL/LLPB/
PM*
NAME NOtto DHarrison DMorey NOtto DATE 8/6/2021 9/9/2021 9/10/2021 9/10/2021