RA-21-0056, Refueling Outage 32 Steam Generator Tube Inspection Report
ML21147A263 | |
Person / Time | |
---|---|
Site: | Robinson ![]() |
Issue date: | 05/26/2021 |
From: | Kapopoulos E Duke Energy Progress |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
RA-21-0056 | |
Download: ML21147A263 (22) | |
Text
Ernest J. Kapopoulos, Jr.
H. B. Robinson Steam Electric Plant Unit 2 Site Vice President Duke Energy 3581 West Entrance Road Hartsville, SC 29550 O: 843 951 1701 F: 843 951 1319 Ernie.Kapopoulos@duke-energy.com Serial: RA-21-0056 TS 5.6.8 May 26, 2021 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261 / RENEWED LICENSE NO. DPR-23
SUBJECT:
Refueling Outage 32 Steam Generator Tube Inspection Report Ladies and Gentlemen:
In accordance with the H. B. Robinson Steam Electric Plant (RNP), Unit No. 2, Technical Specifications (TS) Section 5.6.8, "Steam Generator Tube Inspection Report," Duke Energy Progress, LLC (Duke Energy) submits the enclosed report. Enclosure 1 provides the steam generator tube inspection report information for RNP Fall 2020 Refueling Outage 32 (RO32) required by TS Section 5.6.8. It is noted, the tabular information provided in the enclosure comprises historical information for all service-induced degradations. All indications identified during RO32 are identified as 2020/11/01 under the INSPDATE column.
No new commitments have been made in this submittal. If you have additional questions, please contact Mr. Art Zaremba, Manager - Regulatory Affairs, at 980-373-2062.
Sincerely, Ernest J. Kapopoulos, Jr.
Site Vice President
Enclosures:
- 1. Refueling Outage 32 Steam Generator Tube Inspection Report cc:
L. Dudes, Regional Administrator USNRC Region II M. Fannon, NRC Senior Resident Inspector T. Hood, NRR Project Manager J. Klos, NRR Project Manager RA-21-0056 Enclosure 1 Refueling Outage 32 Steam Generator Tube Inspection Report (21 pages including cover)
HB Robinson R2R32 Steam Generator Tube Inspection Report Pursuant to Robinson technical specification 5.6.8 the following information is provided:
- a. The scope of inspections performed on each SG The primary inspection scope for the all three steam generators is as follows:
Bobbin Inspection
- 100% full length (except Row 1 and 2 U-bend region)
- Row 1-2 hot leg straight section
- Row 1-2 cold leg straight section Array Inspection
- 100% TTS hot leg (TEH to TSH+4)
- periphery / open lane 5 tubes deep on both the hot leg and cold leg to the first tube support plate
- Special interest
- 100% Rows 1 and 2 U-bends
- 20% Row 9 U-bends
- Full length of tubes screened as high stress (-2-sigma)
- Dents/dings >4 Volts
- All dents at the upper tube support plate (6H,6C +/- 1.25 inches) regardless of voltage.
Pre-Planned Array Special Interest
- All tube locations with indication calls that required Array sizing from R2R30. (unplugged)
- Tubes with PLP calls as well as a bounding inspection of one tube deep. For PLP indications with tube degradation,
- Bounding inspection 2 tubes deep surrounding known and new foreign object locations even if object is removed.
- New wear indications
- All bobbin I-codes RPC Inspection
- RPC inspection (Plus Point) as needed Visual Inspection
- Previously installed plugs
- Bowl cladding Inspection
- Foreign object search and retrieval (FOSAR) was performed in all three steam generators Miscellaneous
- Tube slippage monitoring (based on bobbin results)
- b. Degradation mechanisms found Tube wear at anti-vibration bars, support plate locations and a presumed foreign object were the only degradation mechanisms found.
- c. Non-destructive examination techniques utilized for each degradation mechanism The Non-destructive examination techniques utilized bobbin coil for the detection and sizing of tube wear. The array probe was utilized as noted above, to characterize selected wear indications and to size the presumed foreign object wear. MRPC (Motorized Rotating Probe Coil Inspection) probes were utilized to characterize selected indications.
- d. Location, orientation (if linear), and measured sizes (if available) of service induced indications The complete listing for service-induced indications is attached.
Twenty-five indications of Anti-Vibration Bar (AVB) wear were reported in eighteen tubes.
The deepest of these flaws measured 34%TW. The maximum growth rate was 0.91 %TW/
EFPY. Five indications of Tube Support Plate (TSP) wear were reported in five tubes. The deepest of these flaws measured 27%TW. The maximum growth rate was 0.61 %TW/EFPY.
Fifty-four (54) indications of foreign object wear were reported in forty-eight tubes. The deepest foreign object wear indication measured 38%TW.
Many historical foreign object wear indications from RO30 were dispositioned as HNC during RO32 inspections upon confirming that the ECT signal has not changed for three successive inspections. Eleven indications in SG A, seven indications in SG B and eight indications in SG C that were previously foreign object wear were determined to be HNC during RO32.
- e. Number of tubes plugged during the inspection outage for each active degradation mechanism No tubes were plugged in either the A SG or B SG, one (1) tube was plugged in the C SG. The tube in C SG was plugged for wear at a tube support plate.
Count A SG B SG C SG Row Column Row Column Row Column 1 None None 45 44
- f. The total number and percentage of tubes plugged to date, and the effective plugging percentage in each steam generator.
Steam Generator* A SG B SG C SG Total Plugs present prior to RO32 9 24 22 55 Plugs added in RO32 0 0 1 1 Total Plugs 9 24 23 56
% Plugged / Effective Plugging % 0.28 0.75 0.72 0.58
- There are 3214 tubes per generator.
- g. The results of condition monitoring, including the results of tube pulls and in-situ pressure testing.
RO32 was 1.86 EFPY, a nominal 24 month fuel cycle. The cumulative SG EFPY for RO29 was 24.67, RO30 was 26.26, RO31 was 27.69, and RO32 was 29.55.
As of RO32, the Robinson steam generators had operated 28.68 EFPY since the first in-service inspection after replacement. In total, the Robinson steam generators had operated
29.55 EFPY since replacement.
Condition Monitoring structural and accident induced leakage integrity was demonstrated for AVB, TSP, and FO wear.
An NDE maximum depth of 50.6%TW or less for AVB wear is sufficient to demonstrate a minimum degraded tube burst pressure of 3P, 4650 psi, at 0.95 probability with 50%
confidence. The worst-case depth for AVB wear observed during the inspection was an NDE depth of 34%TW.
An NDE maximum depth call of 51.7%TW or less for TSP wear is sufficient to demonstrate a minimum degraded tube burst pressure of 3P, 4650 psi, at 0.95 probability with 50%
confidence. The worst-case depth for TSP wear observed during the inspection was an NDE depth of 27%TW.
An NDE maximum depth call of 50.5%TW or less for FO wear is sufficient to demonstrate a minimum degraded tube burst pressure of 3P, 4650 psi, at 0.95 probability with 50%
confidence. The worst-case depth for FO wear observed during the inspection was an NDE depth of 38%TW.
No degradation was detected in the plug visual or bowl cladding inspections.
No in-situ tests or tube pulls were performed.
A top of tubesheet sludge lancing was performed in all three steam generators during RO32.
There were 65.5 pounds removed from A SG, 55.4 pounds removed from B SG and 64.6 pounds removed from C SG. The total deposits removed was 185.5 pounds.
Foreign Object Search and Retrieval (FOSAR) was performed in the in all three steam generators. There were six metallic objects identified two were removed, one (machine curl) was previously plugged around during EOC 30, three were left in place as is and were evaluated. The part that was previously plugged around during EOC 30 is still there in EOC
- 32. The wear evaluation concluded that the metallic objects can remain in the steam generator for 6 EFPY (three cycles) of operation.
No other secondary side work was performed.
- h. The primary to secondary leakage rate observed in each SG (if it is not practical to assign the leakage to an individual SG, the entire primary to secondary leakage should be conservatively assumed to be from one SG) during the cycle preceding the inspection that is the subject of the report.,
There was no leakage identified within detectable limits
- i. The calculated accident induced leakage rate from the portion of the tubes below 18.11 inches from the top of the tubesheet for the most limiting accident in the most limiting SG. In addition, if the calculated accident induced leakage rate from the most limiting accident is less than 1.87 times the maximum operational primary to secondary leakage rate, the report should describe how it was determined.
There was no leakage identified within detectable limits and no calculated leakage from other
mechanisms.
- j. The results of monitoring for tube axial displacement (slippage). If slippage is discovered, the implications of the discovery and corrective action shall be provided.
No tube slippage was identified.
List of Service Induced Indications Robinson R2R32
SG - A Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2010/04/01 1 1 .20 75 PCT 15 P6 CTS 13.63 SR CTS FBC .720 ZRSNR 42 C 88l l 2007/04/01 1 1 .09 0 PCT 13 P6 CTS 13.72 SAR CTS FBC .720 ZPS3C 38 C 36l l 2004/05/01 1 1 .40 0 PCT 19 P6 CTS 13.72 SAR CTS FBC .700 ZPS3C 32 C 10l l 2002/10/01 1 1 .25 0 PCT 10 P3 CTS 13.72 CTS FBC .700 ZPS3C 1 C 5l l 1999/10/01 1 1 .04 0 PCT 11 P3 CTS 13.30 CTS FBC .720 ZRS3C 24 C l l l l 2010/04/01 7 1 .34 99 PCT 19 P6 CTS .58 SR CTS CTS .720 ZRSNR 44 C 76l l 2010/04/01 7 1 .24 71 PCT 17 P6 CTS .59 SR CTS CTS .720 ZRSNR 44 C 76l l 2007/04/01 7 1 .36 0 PCT 18 P6 CTS .68 SAR CTS CTS .720 ZPS3C 40 C 27l l 2007/04/01 7 1 .23 0 PCT 14 P6 CTS .69 SAR CTS CTS .720 ZPS3C 40 C 27l l 2004/05/01 7 1 .34 0 PCT 18 P6 CTS .68 SAR CTS CTS .700 ZPS3C 32 C 16l l 2002/10/01 7 1 .37 0 PCT 14 P3 CTS .68 CTS CTS .700 ZPS3C 1 C 6l l 1999/10/01 7 1 .06 0 PCT 19 P3 CTS .55 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 7 1 .06 0 PCT 18 P3 CTS .56 CTS CTS .720 ZRS3C 24 C l l l l 2010/04/01 1 2 .14 36 PCT 13 P6 CTS 13.67 SR CTS FBC .720 ZRSNR 42 C 87l l 2007/04/01 1 2 .14 0 PCT 13 P6 CTS 13.74 SAR CTS 01C .720 ZPS3C 38 C 37l l 2004/05/01 1 2 .21 0 PCT 15 P6 CTS 13.74 SAR CTS FBC .700 ZPS3C 32 C 11l l 2002/10/01 1 2 .26 0 PCT 11 P3 CTS 13.74 CTS FBC .700 ZPS3C 1 C 11l l 1999/10/01 1 2 .08 0 PCT 22 P3 CTS 14.10 CTS FBC .720 ZRS3C 24 C l l l l 2010/04/01 11 2 .19 120 PCT 16 P6 CTS .57 SR CTS CTS .720 ZRSNR 44 C 81l l 2007/04/01 11 2 .30 0 PCT 17 P6 CTS .54 SAR CTS CTS .720 ZPS3C 38 C 35l l 2004/05/01 11 2 .40 0 PCT 20 P6 CTS .54 SAR CTS CTS .700 ZPS3C 35 C 8l l 2002/10/01 11 2 .27 0 PCT 11 P3 CTS .55 CTS CTS .700 ZPS3C 1 C 7l l 1999/10/01 11 2 .06 0 PCT 19 P3 CTS .52 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 11 2 .05 0 PCT 15 P3 CTS .57 CTS CTS .720 ZRS3C 24 C l l l l 2010/04/01 1 3 .29 83 PCT 19 P6 CTS 15.66 SR CTS FBC .720 ZRSNR 42 C 86l l 2007/04/01 1 3 .30 0 PCT 17 P6 CTS 15.66 SAR CTS FBC .720 ZPS3C 38 C 38l l 2004/05/01 1 3 .38 0 PCT 19 P6 CTS 15.66 SAR CTS FBC .700 ZPS3C 32 C 12l l 2002/10/01 1 3 .35 0 PCT 13 P3 CTS 15.66 CTS FBC .700 ZPS3C 1 C 12l l 1999/10/01 1 3 .07 0 PCT 19 P3 CTS 15.59 CTS 01C .720 ZRS3C 23 C l l 1996/09/01 1 3 .67 161 PCT 16 1 CTS 15.38 R96A14 06H CTE .680 ZBASF 19 C l l l l 1996/09/01 7 3 .37 151 PCT 28 1 01C 25.55 R96A02 HTE CTE .720 ZBAGB 5 C l l 1993/09/01 7 3 .44 156 PCT 23 1 01C 25.69 R93A01 CTE HTE .720 ZBAGB 1 H l l l l 2010/04/01 13 3 .34 77 PCT 19 P6 CTS .54 SR CTS CTS .720 ZRSNR 44 C 83l l 2007/04/01 13 3 .26 0 PCT 16 P6 CTS .45 SAR CTS CTS .720 ZPS3C 38 C 34l l 2004/05/01 13 3 .38 0 PCT 22 P6 CTS .45 SRADABA CTS CTS .700 ZPS3C 33 C 9l l 2002/10/01 13 3 .31 0 PCT 12 P3 CTS .48 CTS CTS .700 ZPS3C 1 C 13l l 1999/10/01 13 3 .09 0 PCT 25 P3 CTS .54 CTS CTS .720 ZRS3C 24 C l l l l 2010/04/01 1 4 .27 146 PCT 17 P6 CTS 15.61 SR CTS FBC .720 ZRSNR 42 C 85l l 2007/04/01 1 4 .33 0 PCT 18 P6 CTS 15.78 SAR CTS FBC .720 ZPS3C 38 C 39l l 2004/05/01 1 4 .41 0 PCT 20 P6 CTS 15.78 SAR CTS FBC .700 ZPS3C 32 C 13l l 2002/10/01 1 4 .56 0 PCT 20 P3 CTS 15.78 CTS FBC .700 ZPS3C 1 C 19l l 1999/10/01 1 4 .10 0 PCT 27 P3 CTS 15.36 CTS 01C .720 ZRS3C 23 C l l 1996/09/01 1 4 .88 159 PCT 18 1 CTS 15.35 R96A14 06H CTE .680 ZBASF 19 C l l l l 2010/04/01 16 4 .26 107 PCT 17 P6 CTS .51 SR CTS CTS .720 ZRSNR 44 C 88l l 2010/04/01 16 4 .15 80 PCT 15 P6 CTS .85 SR CTS CTS .720 ZRSNR 44 C 88l l 2007/04/01 16 4 .36 0 PCT 19 P6 CTS .41 SAR CTS CTS .720 ZPS3C 38 C 33l l 2007/04/01 16 4 .13 0 PCT 13 P6 CTS .84 SAR CTS CTS .720 ZPS3C 38 C 33l l 2004/05/01 16 4 .26 0 PCT 19 P6 CTS .41 SAR CTS CTS .700 ZPS3C 33 C 10l l 2004/05/01 16 4 .13 0 PCT 17 P6 CTS .84 SAR CTS CTS .700 ZPS3C 33 C 10l l 2002/10/01 16 4 .25 0 PCT 10 P3 CTS .41 CTS CTS .700 ZPS3C 1 C 14l l 1999/10/01 16 4 .04 0 PCT 12 P3 CTS .47 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 16 4 .07 0 PCT 20 P3 CTS .55 CTS CTS .720 ZRS3C 24 C l l l l 2010/04/01 1 5 .27 78 PCT 19 P6 CTS 15.76 SR CTS FBC .720 ZRSNR 42 C 84l l 2007/04/01 1 5 .24 0 PCT 16 P6 CTS 15.76 SAR CTS FBC .720 ZPS3C 38 C 40l l 2004/05/01 1 5 .27 0 PCT 16 P6 CTS 15.76 SAR CTS FBC .700 ZPS3C 32 C 14l l 2002/10/01 1 5 .17 0 PCT 7 P3 CTS 15.54 CTS FBC .700 ZPS3C 1 C 20l l 1999/10/01 1 5 .05 0 PCT 15 P3 CTS 15.28 CTS FBC .720 ZRS3C 24 C l l l l 2010/04/01 1 6 .31 102 PCT 18 P6 CTS 15.59 SR CTS FBC .720 ZRSNR 42 C 83l l 2007/04/01 1 6 .26 0 PCT 17 P6 CTS 15.57 SAR CTS FBC .720 ZPS3C 38 C 41l l 2004/05/01 1 6 .28 0 PCT 17 P6 CTS 15.57 SAR CTS FBC .700 ZPS3C 32 C 15l l 2002/10/01 1 6 .29 0 PCT 11 P3 CTS 15.57 CTS FBC .700 ZPS3C 1 C 21l l 1999/10/01 1 6 .08 0 PCT 22 P3 CTS 15.45 CTS 01C .720 ZRS3C 23 C l l 1996/09/01 1 6 .79 162 PCT 15 1 CTS 15.29 R96A14 06H CTE .680 ZBASF 19 C l l l l 2017/03/01 15 6 .62 122 PCT 20 Q1 01H -.65 .25 .29 01H HTE .720 ZYAX2 6 H 109l l 2014/03/01 15 6 .97 113 PCT 20 P24 01H -.69 01H HTE .720 ZYAAP 26 H 106l l 2013/10/01 15 6 .68 105 PCT 20 Q9 01H -.72 -.53 0.37 0.19 01H HTE .720 ZYAXA 32 H 13l l l l 2010/04/01 23 7 .14 92 PCT 16 P6 CTS .50 SR CTS CTS .720 ZRSNR 46 C 14l l 2007/04/01 23 7 .28 0 PCT 17 P6 CTS .50 SAR CTS CTS .720 ZPS3C 38 C 32l l 2004/05/01 23 7 .26 0 PCT 19 P6 CTS .50 SAR CTS CTS .700 ZPS3C 33 C 11l l 2002/10/01 23 7 .28 0 PCT 11 P3 CTS .71 CTS CTS .700 ZPS3C 1 C 22l l 1999/10/01 23 7 .10 0 PCT 26 P3 CTS .55 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 23 7 .05 0 PCT 14 P3 CTS .57 CTS CTS .720 ZRS3C 24 C l l l l 1987/05/01 3 8 .57 163 PCT 18 1 03C 26.20 CTE HTE .680 ZBAGB 6 H l l l l 2020/11/01 13 9 1.50 86 PCT 24 22 02H -.73 17902.1 24 .33 .51 02H 02H .720 ZYAX2 27 H 12l l l l 2010/04/01 26 9 .24 100 PCT 15 P6 CTS .55 SR CTS CTS .720 ZRSNR 46 C 16l l 2007/04/01 26 9 .25 0 PCT 16 P6 CTS .50 SAR CTS CTS .720 ZPS3C 38 C 31l l 2004/05/01 26 9 .36 0 PCT 21 P6 CTS .50 SAR CTS CTS .700 ZPS3C 33 C 12l l 2002/10/01 26 9 .35 0 PCT 13 P3 CTS .62 CTS CTS .700 ZPS3C 1 C 23l l 1999/10/01 26 9 .10 0 PCT 27 P3 CTS .55 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 26 9 .07 0 PCT 19 P3 CTS .63 CTS CTS .720 ZRS3C 24 C l l l l 2017/03/01 23 14 .78 337 PCT 22 Q1 HTS .00 .36 .29 01H HTE .720 ZYAX2 3 H 136l l 2014/03/01 23 14 .91 0 PCT 23 P45 HTS -.13 01H HTE .720 ZYAAP 26 H 155l l 2013/10/01 23 14 .73 113 PCT 21 Q10 HTS -.07 .16 0.37 0.23 01H HTE .720 ZYAXA 26 H 39l l 2010/04/01 23 14 .70 117 PCT 26 P6 HTS .08 SR HTS HTS .720 ZRSNR 53 H 20l l 2007/04/01 23 14 .56 0 PCT 23 P6 HTS .05 SAR HTS HTS .720 ZPS3C 39 H 9l l 2004/05/01 23 14 .54 0 PCT 24 P6 HTS .05 SAR HTS HTS .700 ZPS3C 14 H 44l l 2002/10/01 23 14 .64 0 PCT 26 P3 HTS .05 SAR HTS HTS .700 ZPS3C 24 H 5l l l l 2010/04/01 33 15 .19 76 PCT 17 P6 CTS .63 SR CTS CTS .720 ZRSNR 48 C 32l l 2007/04/01 33 15 .29 0 PCT 16 P6 CTS .48 SAR CTS CTS .720 ZPS3C 40 C 26l l 2004/05/01 33 15 .41 0 PCT 21 P6 CTS .48 SAR CTS CTS .700 ZPS3C 33 C 13l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
1 ST Max
SG - A Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2002/10/01 33 15 .21 0 PCT 9 P3 CTS .54 CTS CTS .700 ZPS3C 1 C 25l l 1999/10/01 33 15 .06 0 PCT 18 P3 CTS .67 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 33 15 .07 0 PCT 20 P3 CTS .67 CTS CTS .720 ZRS3C 24 C l l l l 2020/11/01 36 20 .76 89 PCT 24 239 03H -.60 17902.3 24 .27 .43 03H 03H .720 ZYAX2 27 H 14l l 2020/11/01 36 20 .86 86 PCT 26 239 04H -.64 17902.3 26 .33 .43 04H 04H .720 ZYAX2 27 H 14l l l l 2020/11/01 37 20 1.15 77 PCT 31 62 04H -.57 17902.3 .27 .43 04H 04H .720 ZYAX2 27 H 15l l 2010/04/01 37 20 .24 158 PCT 15 P6 HTS .61 SR HTS HTS .720 ZRSNR 53 H 47l l 2007/04/01 37 20 .23 0 PCT 15 P6 HTS .63 SAR HTS HTS .720 ZPS3C 39 H 17l l 2004/05/01 37 20 .20 0 PCT 17 P6 HTS .63 SAR HTS HTS .700 ZPS3C 14 H 47l l 2002/10/01 37 20 .25 0 PCT 15 P3 HTS .64 SAR HTS HTS .700 ZPS3C 22 H 15l l 1999/10/01 37 20 .07 0 PCT 19 P3 HTS .63 HTS HTS .700 ZRS3C 34 H l l 1996/09/01 37 20 .60 154 PCT 27 1 HTS .60 R96A06 HTE CTE .720 ZBAGB 8 C l l l l 2017/03/01 31 21 .67 68 PCT 20 Q12 HTS -.08 .23 .36 01H HTE .720 ZYAX2 4 H 60l l 2014/03/01 31 21 .60 0 PCT 18 P10 HTS -.13 01H HTE .720 ZYAAP 30 H 70l l 2013/10/01 31 21 .64 80 PCT 20 Q7 HTS -.09 .14 0.37 0.23 01H HTE .720 ZYAXA 26 H 40l l l l 2020/11/01 36 22 .22 78 PCT 10 P4 02A .00 WAR CTE HTE .720 ZBAHS 11 H 218l l 2017/03/01 36 22 .23 78 PCT 11 P4 02A -.12 WAR CTE HTE .720 ZBAHS 18 H 142l l l l 1987/05/01 22 23 1.89 193 PCT 1 1 01H 23.10 CTE HTE .720 ZBASF 1 H l l l l 1987/05/01 26 24 1.48 179 PCT 3 1 05H 37.70 CTE HTE .720 ZBASF 1 H l l l l 2013/10/01 37 24 .24 47 PCT 14 Q19 CTS 19.41 19.61 0.37 0.20 FBC CTE .720 ZYAXA 29 C 13l l l l 1987/05/01 33 25 3.20 168 PCT 14 1 05H 43.09 CTE HTE .720 ZBASF 1 H l l 1987/05/01 33 25 1.35 160 PCT 22 1 05C 23.70 CTE HTE .720 ZBASF 1 H l l 1987/05/01 33 25 1.38 169 PCT 13 1 05C 33.79 CTE HTE .720 ZBASF 1 H l l 1987/05/01 33 25 .84 160 PCT 22 1 04C 4.50 CTE HTE .720 ZBASF 1 H l l l l 2010/04/01 40 25 .23 57 PCT 18 P6 CTS .47 SR CTS CTS .720 ZRSNR 48 C 50l l 2010/04/01 40 25 .30 66 PCT 19 P6 CTS .68 SR CTS CTS .720 ZRSNR 48 C 50l l 2007/04/01 40 25 .37 0 PCT 18 P6 CTS .47 SAR CTS CTS .720 ZPS3C 40 C 24l l 2007/04/01 40 25 .22 0 PCT 14 P6 CTS .68 SAR CTS CTS .720 ZPS3C 40 C 24l l 2004/05/01 40 25 .34 0 PCT 21 P6 CTS .47 SAR CTS CTS .700 ZPS3C 33 C 14l l 2004/05/01 40 25 .22 0 PCT 18 P6 CTS .68 SAR CTS CTS .700 ZPS3C 33 C 14l l 2002/10/01 40 25 .37 0 PCT 14 P3 CTS .47 CTS CTS .700 ZPS3C 1 C 26l l 1999/10/01 40 25 .09 0 PCT 23 P3 CTS .52 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 40 25 .10 0 PCT 27 P3 CTS .57 CTS CTS .720 ZRS3C 24 C l l l l 1996/09/01 27 29 .79 62 PCT 03A 5.89 96A08 HTE CTE .720 ZBAGB 11 l l 1993/09/01 27 29 .85 160 PCT 19 1 06H 74.89 R93A01 CTE HTE .720 ZBAGB 5 H l l l l 2020/11/01 31 30 .54 54 PCT 20 239 HTS -.19 17902.3 19 .18 .51 01H HTE .720 ZYAX2 4 H 8l l 2017/03/01 31 30 .61 118 PCT 20 Q1 HTS -.08 .36 .36 01H HTE .720 ZYAX2 1 H 248l l 2013/10/01 31 30 .47 113 PCT 18 Q8 HTS -.02 .16 0.37 0.18 01H HTE .720 ZYAXA 32 H 14l l l l 2010/04/01 42 30 .26 68 PCT 18 P6 CTS .47 SR CTS CTS .720 ZRSNR 48 C 57l l 2010/04/01 42 30 .14 97 PCT 12 P6 HTS .68 SR HTS HTS .720 ZRSNR 53 H 48l l 2010/04/01 42 30 .15 120 PCT 13 P6 HTS .90 SR HTS HTS .720 ZRSNR 53 H 48l l 2007/04/01 42 30 .12 0 PCT 13 P6 HTS .63 SAR HTS HTS .720 ZPS3C 39 H 19l l 2007/04/01 42 30 .16 0 PCT 14 P6 HTS .95 SAR HTS HTS .720 ZPS3C 39 H 19l l 2007/04/01 42 30 .27 0 PCT 16 P6 CTS .47 SAR CTS CTS .720 ZPS3C 40 C 23l l 2004/05/01 42 30 .17 0 PCT 16 P6 HTS .63 SAR HTS HTS .700 ZPS3C 14 H 50l l 2004/05/01 42 30 .18 0 PCT 16 P6 HTS .95 SAR HTS HTS .700 ZPS3C 14 H 50l l 2004/05/01 42 30 .27 0 PCT 19 P6 CTS .47 SAR CTS CTS .700 ZPS3C 33 C 15l l 2002/10/01 42 30 .32 0 PCT 13 P3 CTS .47 CTS CTS .700 ZPS3C 1 C 27l l 2002/10/01 42 30 .12 0 PCT 11 P3 HTS .62 SAR HTS HTS .700 ZPS3C 22 H 14l l 1999/10/01 42 30 .09 0 PCT 25 P3 CTS .57 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 42 30 .08 0 PCT 22 P3 CTS .58 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 42 30 .05 0 PCT 20 P3 HTS .63 HTS HTS .700 ZRS3C 42 H l l l l 1996/09/01 10 33 1.06 168 PCT 9 1 02C 4.32 R96A08 HTE CTE .720 ZBAGB 12 C l l l l 2010/04/01 43 33 .22 105 PCT 17 P6 CTS .56 SR CTS CTS .720 ZRSNR 48 C 60l l 2010/04/01 43 33 .21 94 PCT 17 P6 CTS .58 SR CTS CTS .720 ZRSNR 48 C 60l l 2007/04/01 43 33 .20 0 PCT 14 P6 CTS .56 SAR CTS CTS .720 ZPS3C 40 C 19l l 2007/04/01 43 33 .19 0 PCT 13 P6 CTS .57 SAR CTS CTS .720 ZPS3C 40 C 19l l 2004/05/01 43 33 .22 0 PCT 18 P6 CTS .56 SAR CTS CTS .700 ZPS3C 33 C 16l l 2004/05/01 43 33 .15 0 PCT 17 P6 CTS .57 SAR CTS CTS .700 ZPS3C 33 C 16l l 2002/10/01 43 33 .25 0 PCT 10 P3 CTS .56 CTS CTS .700 ZPS3C 1 C 30l l 1999/10/01 43 33 .04 0 PCT 11 P3 CTS .55 CTS CTS .720 ZRS3C 24 C l l 1999/10/01 43 33 .07 0 PCT 20 P3 CTS .59 CTS CTS .720 ZRS3C 24 C l l l l 2004/05/01 15 35 .26 0 PCT 18 P6 03C -.97 SAR 03C 03C .700 ZPS3C 33 C 17l l 2002/10/01 15 35 .32 0 PCT 20 P3 02C 51.00 SAR 02C 03C .700 ZPS3C 28 C 4l l l l 2010/04/01 44 36 .20 89 PCT 13 P6 CTS .64 SR CTS FBC .720 ZRSNR 46 C 62l l 2010/04/01 44 36 .24 114 PCT 15 P6 CTS 1.75 SR CTS FBC .720 ZRSNR 46 C 62l l 2007/04/01 44 36 .33 0 PCT 18 P6 CTS .64 SAR CTS CTS .720 ZPS3C 38 C 21l l 2007/04/01 44 36 .22 0 PCT 15 P6 CTS 1.69 SAR CTS CTS .720 ZPS3C 38 C 21l l 2004/05/01 44 36 .19 0 PCT 18 P6 CTS .60 SAR CTS CTS .700 ZPS3C 33 C 20l l 2002/10/01 44 36 .36 0 PCT 14 P3 CTS .60 CTS CTS .700 ZPS3C 1 C 32l l 1999/10/01 44 36 .08 0 PCT 22 P3 CTS .60 CTS CTS .720 ZRS3C 23 C l l 1996/09/01 44 36 1.46 150 PCT 30 1 CTS .55 R96A10 HTE CTE .720 ZBAGB 13 C l l l l 2010/04/01 43 37 .19 139 PCT 17 P6 CTS .55 SR CTS FBC .720 ZRSNR 48 C 67l l 2010/04/01 43 37 .26 88 PCT 18 P6 CTS 1.75 SR CTS FBC .720 ZRSNR 48 C 67l l 2007/04/01 43 37 .25 0 PCT 15 P6 CTS .55 SAR CTS CTS .720 ZPS3C 40 C 18l l 2007/04/01 43 37 .30 0 PCT 16 P6 CTS 1.75 SAR CTS CTS .720 ZPS3C 40 C 18l l 2004/05/01 43 37 .26 0 PCT 19 P6 CTS .55 SAR CTS CTS .700 ZPS3C 33 C 19l l 2004/05/01 43 37 .29 0 PCT 20 P6 CTS 1.75 SAR CTS CTS .700 ZPS3C 33 C 19l l 2002/10/01 43 37 .25 0 PCT 10 P3 CTS .55 CTS CTS .700 ZPS3C 1 C 35l l 2002/10/01 43 37 .25 0 PCT 10 P3 CTS 1.75 CTS CTS .700 ZPS3C 1 C 35l l 1999/10/01 43 37 .08 0 PCT 22 P3 CTS .55 CTS CTS .720 ZRS3C 23 C l l 1996/09/01 43 37 .50 163 PCT 17 1 CTS .55 R96A10 HTE CTE .720 ZBAGB 13 C l l 1996/09/01 43 37 .16 159 PCT 21 1 CTS 1.64 R96A10 HTE CTE .720 ZBAGB 13 C l l l l 1996/09/01 3 38 .80 164 PCT 15 1 01H 21.14 R96A16 HTE CTE .700 ZBASF 23 C l l 1993/09/01 3 38 .91 157 PCT 19 1 01H 20.39 R93A04 CTE .700 ZBASF 15 H l l 1992/04/01 3 38 .92 154 PCT 25 1 01H 20.68 R92A03 CTE HTE .700 ZBASF 12 H l l l l 1996/09/01 34 38 .58 163 PCT 17 1 02H 47.28 R96A10 HTE CTE .720 ZBAGB 13 C l l l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
2 ST Max
SG - A Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2002/10/01 4 39 .42 99 PCT 37 P3 03C -.88 SAR 03C 03C .700 ZPS3C 28 C 5l l l l 2017/03/01 8 40 2.70 110 SCI 239 HTE .13 01H HTE .720 ZYAX2 7 H 79l l 2013/10/01 8 40 3.28 39 SCI 2 HTE .00 01H HTE .720 ZYAXA 20 H 87l l l l 2020/11/01 33 41 .60 90 PCT 21 206 HTS .07 17902.3 20 .16 .51 01H HTE .720 ZYAX2 4 H 165l l 2017/03/01 33 41 .88 107 PCT 23 Q1 HTS -.08 .30 .36 01H HTE .720 ZYAX2 1 H 90l l 2013/10/01 33 41 .86 82 PCT 22 Q9 HTS -.09 .12 0.37 0.21 01H HTE .720 ZYAXA 26 H 15l l 2010/04/01 33 41 .54 90 PCT 23 P6 HTS .10 SR HTE HTS .720 ZRSNR 53 H 33l l 2007/04/01 33 41 .50 0 PCT 22 P6 HTS .10 SAR HTS HTS .720 ZPS3C 39 H 21l l 2004/05/01 33 41 .60 0 PCT 25 P6 HTS .10 SAR HTS HTS .700 ZPS3C 14 H 39l l 2002/10/01 33 41 .45 0 PCT 26 P3 HTS .04 SAR HTS HTS .700 ZPS3C 24 H 17l l l l 2010/04/01 34 41 .58 91 PCT 24 P6 HTS .07 SR HTS HTS .720 ZRSNR 53 H 34l l 2007/04/01 34 41 .53 0 PCT 23 P6 HTS .09 SAR HTS HTS .720 ZPS3C 39 H 20l l 2004/05/01 34 41 .55 0 PCT 24 P6 HTS .09 SAR HTS HTS .700 ZPS3C 14 H 36l l 2002/10/01 34 41 .60 0 PCT 25 P3 HTS .13 SAR HTS HTS .700 ZPS3C 24 H 18l l l l 2010/04/01 45 41 .20 72 PCT 13 P6 CTS .66 HR&SR CTS CTS .720 ZRSNR 46 C 61l l 2007/04/01 45 41 .28 0 PCT 17 P6 CTS .61 SAR CTS CTS .720 ZPS3C 38 C 20l l 2004/05/01 45 41 .28 0 PCT 20 P6 CTS .62 SAR CTS CTS .700 ZPS3C 33 C 21l l 2002/10/01 45 41 .53 0 PCT 19 P3 CTS .62 CTS CTS .700 ZPS3C 1 C 36l l 1999/10/01 45 41 .09 0 PCT 26 P3 CTS .63 CTS CTS .720 ZRS3C 23 C l l 1999/10/01 45 41 .09 0 PCT 26 P3 CTS .64 CTS CTS .720 ZRS3C 23 C l l 1996/09/01 45 41 .78 145 PCT 34 1 CTS .58 R96A10 HTE CTE .720 ZBAGB 14 C l l l l 2017/03/01 27 42 .60 55 PCT 20 Q1 03H -.60 .35 .43 03H 03H .720 ZYAX2 37 H 7l l 2014/03/01 27 42 .93 102 PCT 21 P52 03H -.79 03H HTE .720 ZYAAP 28 H 118l l 2013/10/01 27 42 .90 97 PCT 23 Q15 03H -.86 -.65 0.37 0.21 03H 03H .720 ZYAXA 33 H 8l l l l 2014/03/01 27 44 .60 0 PCT 20 P56 05C -.77 05C CTE .720 ZYAAP 31 C 7l l 2013/10/01 27 44 .61 99 PCT 20 Q18 05C -.88 -.67 0.37 0.21 05C 05C .720 ZYAXA 25 C 35l l 2010/04/01 27 44 .44 96 PCT 21 P6 05C -.82 SR 05C 05C .720 ZRSNR 46 C 83l l 2007/04/01 27 44 .40 0 PCT 21 P6 05C -.75 SAR 05C 05C .720 ZPS3C 60 C 6l l l l 1996/09/01 44 47 .21 148 PCT 32 1 FBC 1.56 R96A12 HTE CTE .720 ZBAGB 16 C l l l l 2014/03/01 45 47 .41 0 PCT 15 P35 CTS 11.70 01C CTE .720 ZYAAP 21 C 123l l 2013/10/01 45 47 .25 155 PCT 14 Q6 CTS 11.51 11.69 0.37 0.18 FBC CTE .720 ZYAXA 29 C 12l l 2010/04/01 45 47 .22 141 PCT 14 P6 CTS 2.70 SR CTS FBC .720 ZRSNR 46 C 72l l 2010/04/01 45 47 .25 162 PCT 15 P6 CTS 6.61 SR CTS FBC .720 ZRSNR 46 C 72l l 2007/04/01 45 47 .21 0 PCT 15 P6 CTS 2.72 SAR CTS FBC .720 ZPS3C 38 C 19l l 2007/04/01 45 47 .32 0 PCT 18 P6 CTS 6.77 SAR CTS FBC .720 ZPS3C 38 C 19l l 2004/05/01 45 47 .21 0 PCT 18 P6 CTS 2.74 SAR CTS FBC .700 ZPS3C 33 C 22l l 2004/05/01 45 47 .32 0 PCT 20 P6 CTS 6.74 SAR CTS FBC .700 ZPS3C 33 C 22l l 2002/10/01 45 47 .34 0 PCT 13 P3 CTS 2.74 CTS FBC .700 ZPS3C 1 C 40l l 2002/10/01 45 47 .26 0 PCT 11 P3 CTS 6.74 CTS FBC .700 ZPS3C 1 C 40l l 1999/10/01 45 47 .08 0 PCT 22 P3 CTS 2.74 CTS 01C .720 ZRS3C 23 C l l 1999/10/01 45 47 .12 0 PCT 30 P3 CTS 6.50 CTS 01C .720 ZRS3C 23 C l l 1996/09/01 45 47 .94 169 PCT 10 1 CTS 6.60 R96A12 HTE CTE .720 ZBAGB 16 C l l l l 1992/04/01 40 49 .54 146 PCT 32 1 05C 26.42 R92A02 CTE HTE .720 ZBAGB 7 H l l l l 2002/10/01 37 50 1.64 0 PCT 41 P3 HTS .04 SAR HTS HTS .700 ZPS3C 24 H 26l l l l 2002/10/01 38 50 1.58 0 PCT 41 P3 HTS .07 SAR HTS HTS .700 ZPS3C 24 H 27l l l l 1996/09/01 12 51 .32 109 PCT 23 3 CTS 6.29 R96A14 HTE CTE .720 ZBAGB 18 C l l l l 2002/10/01 37 51 1.18 0 PCT 37 P3 HTS .04 SAR HTS HTS .700 ZPS3C 27 H 4l l l l 2010/04/01 45 52 .36 73 PCT 18 P6 CTS .55 SR CTS FBC .720 ZRSNR 46 C 79l l 2010/04/01 45 52 .31 90 PCT 17 P6 CTS .61 SR CTS FBC .720 ZRSNR 46 C 79l l 2010/04/01 45 52 .20 110 PCT 13 P6 CTS 3.67 SR CTS FBC .720 ZRSNR 46 C 79l l 2007/04/01 45 52 .33 0 PCT 18 P6 CTS .57 SAR CTS CTS .720 ZPS3C 38 C 18l l 2007/04/01 45 52 .36 0 PCT 19 P6 CTS .63 SAR CTS CTS .720 ZPS3C 38 C 18l l 2007/04/01 45 52 .22 0 PCT 15 P6 CTS 3.78 SAR CTS CTS .720 ZPS3C 38 C 18l l 2004/05/01 45 52 .33 0 PCT 21 P6 CTS .44 SAR CTS CTS .700 ZPS3C 33 C 24l l 2004/05/01 45 52 .52 0 PCT 22 P6 CTS .55 SAR CTS CTS .700 ZPS3C 33 C 24l l 2004/05/01 45 52 .24 0 PCT 18 P6 CTS 3.79 SAR CTS CTS .700 ZPS3C 33 C 24l l 2002/10/01 45 52 .46 0 PCT 17 P3 CTS .49 CTS FBC .700 ZPS3C 1 C 41l l 2002/10/01 45 52 .20 0 PCT 8 P3 CTS 3.72 CTS FBC .700 ZPS3C 1 C 41l l 1999/10/01 45 52 .14 0 PCT 29 P3 CTS .60 CTS FBC .700 ZRS3C 32 C l l 1999/10/01 45 52 .07 0 PCT 17 P3 CTS 3.72 CTS FBC .700 ZRS3C 32 C l l l l 2017/03/01 41 53 .26 151 PCT 14 Q1 HTS -.03 .30 .22 01H HTE .720 ZYAX2 7 H 182l l 2014/03/01 41 53 .64 0 PCT 20 P54 HTS -.17 01H HTE .720 ZYAAP 32 H 40l l 2013/10/01 41 53 .73 64 PCT 21 Q6 HTS -.07 .14 0.37 0.21 01H HTE .720 ZYAXA 26 H 35l l 2010/04/01 41 53 .78 96 PCT 29 P6 HTS .08 SR HTS HTS .720 ZRSNR 53 H 58l l 2007/04/01 41 53 .72 0 PCT 27 P6 HTS .07 SAR HTS HTS .720 ZPS3C 39 H 25l l 2004/05/01 41 53 .72 0 PCT 27 P6 HTS .07 SAR HTS HTS .700 ZPS3C 14 H 33l l 2002/10/01 41 53 .81 0 PCT 29 P3 HTS .08 SAR HTS HTS .700 ZPS3C 24 H 38l l l l 2017/03/01 24 54 .75 57 PCT 21 Q1 03H -.58 .26 .22 03H 03H .720 ZYAX2 37 H 13l l 2014/03/01 24 54 1.05 0 PCT 24 P40 03H -.57 03H HTE .720 ZYAAP 34 H 111l l 2013/10/01 24 54 .82 86 PCT 22 Q19 03H -.79 -.55 0.45 0.23 03H 03H .720 ZYAXA 33 H 9l l 2010/04/01 24 54 .49 105 PCT 22 P6 03H -.70 03H 03H .720 ZRSNR 53 H 64l l 2007/04/01 24 54 .57 83 PCT 24 P6 03H -.72 DQABA SAR 03H 03H .720 ZPS3C 47 H 28l l 2004/05/01 24 54 .60 0 PCT 25 P6 03H -.61 SAR 03H 03H .700 ZPS3C 14 H 18l l 2002/10/01 24 54 .47 0 PCT 20 P3 03H -.75 SAR 03H 03H .700 ZPS3C 22 H 6l l l l 1996/09/01 44 54 .30 146 PCT 34 1 05C 26.24 R96A16 HTE CTE .720 ZBAGB 26 C l l l l 2020/11/01 13 56 .55 68 PCT 15 162 04H -.65 17902.1 16 .36 .29 04H 04H .720 ZYAX2 9 H 103l l 2017/03/01 13 56 .47 141 PCT 16 P1 04H -.59 .30 .36 04H 04H .720 ZYAX2 37 H 48l l 2014/03/01 13 56 .92 0 PCT 23 P50 04H .48 .08 .36 04H HTE .720 ZYAAP 36 H 12l l l l 1996/09/01 17 56 .31 150 PCT 30 1 CTS 2.95 R96A16 HTE CTE .720 ZBAGB 26 C l l 1996/09/01 17 56 .26 161 PCT 19 1 CTS 4.03 R96A16 HTE CTE .720 ZBAGB 26 C l l l l 2020/11/01 44 57 .21 133 PCT 10 P4 04A .07 WAR CTE HTE .720 ZBAHS 15 H 168l l 2017/03/01 44 57 .06 162 PCT 8 Q1 HTS .58 .20 .14 01H HTE .720 ZYAX2 8 H 231l l 2010/04/01 44 57 .23 148 PCT 14 P6 CTS .50 SR CTS FBC .720 ZRSNR 46 C 87l l 2010/04/01 44 57 .27 117 PCT 15 P6 CTS .57 SR CTS FBC .720 ZRSNR 46 C 87l l 2010/04/01 44 57 .10 113 PCT 10 P6 CTS 1.00 SR CTS FBC .720 ZRSNR 46 C 87l l 2010/04/01 44 57 .21 80 PCT 14 P6 CTS 1.94 SR CTS FBC .720 ZRSNR 46 C 87l l 2010/04/01 44 57 .23 111 PCT 15 P6 HTS .77 SR HTS FBH .720 ZRSNR 53 H 61l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
3 ST Max
SG - A Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2010/04/01 44 57 .26 104 PCT 16 P6 HTS 1.27 SR HTS FBH .720 ZRSNR 53 H 61l l 2007/04/01 44 57 .22 0 PCT 16 P6 CTS .60 SAR CTS CTS .720 ZPS3C 38 C 17l l 2007/04/01 44 57 .41 0 PCT 20 P6 CTS .61 SAR CTS CTS .720 ZPS3C 38 C 17l l 2007/04/01 44 57 .10 0 PCT 13 P6 CTS 1.00 SAR CTS CTS .720 ZPS3C 38 C 17l l 2007/04/01 44 57 .25 0 PCT 16 P6 CTS 1.97 SAR CTS CTS .720 ZPS3C 38 C 17l l 2007/04/01 44 57 .13 0 PCT 13 P6 HTS .67 SAR HTS HTS .720 ZPS3C 39 H 26l l 2007/04/01 44 57 .22 0 PCT 15 P6 HTS 1.11 SAR HTS HTS .720 ZPS3C 39 H 26l l 2004/05/01 44 57 .20 0 PCT 17 P6 HTS .67 SRADABA HTS HTS .700 ZPS3C 14 H 30l l 2004/05/01 44 57 .23 0 PCT 18 P6 HTS 1.11 SAR HTS HTS .700 ZPS3C 14 H 30l l 2004/05/01 44 57 .33 0 PCT 21 P6 CTS .51 SAR CTS CTS .700 ZPS3C 33 C 25l l 2004/05/01 44 57 .23 0 PCT 19 P6 CTS .55 SAR CTS CTS .700 ZPS3C 33 C 25l l 2004/05/01 44 57 .12 0 PCT 16 P6 CTS .99 SAR CTS CTS .700 ZPS3C 33 C 25l l 2004/05/01 44 57 .24 0 PCT 19 P6 CTS 1.89 SAR CTS CTS .700 ZPS3C 33 C 25l l 2002/10/01 44 57 .62 0 PCT 21 P3 CTS .59 CTS CTS .700 ZPS3C 1 C 42l l 2002/10/01 44 57 .16 0 PCT 12 P3 HTS .70 SAR HTS HTS .700 ZPS3C 22 H 7l l 2002/10/01 44 57 .22 0 PCT 14 P3 HTS 1.20 SAR HTS HTS .700 ZPS3C 22 H 7l l 1999/10/01 44 57 .11 0 PCT 26 P3 CTS .46 CTS CTS .700 ZRS3C 31 C l l 1999/10/01 44 57 .07 0 PCT 17 P3 CTS .61 CTS CTS .700 ZRS3C 31 C l l 1999/10/01 44 57 .10 0 PCT 24 P3 CTS .64 CTS CTS .700 ZRS3C 31 C l l 1999/10/01 44 57 .06 0 PCT 16 P3 HTS .70 HTS HTS .700 ZRS3C 34 H l l 1996/09/01 44 57 .84 163 PCT 16 1 HTS .66 R96A18 HTE CTE .720 ZBAGB 27 C l l l l 2010/04/01 43 60 .34 135 PCT 18 P6 CTS .59 SR CTS CTS .720 ZRSNR 46 C 92l l 2007/04/01 43 60 .39 0 PCT 19 P6 CTS .61 SAR CTS CTS .720 ZPS3C 38 C 16l l 2004/05/01 43 60 .51 0 PCT 22 P6 CTS .59 SAR CTS CTS .700 ZPS3C 33 C 26l l 2002/10/01 43 60 .46 0 PCT 17 P3 CTS .56 CTS CTS .700 ZPS3C 1 C 43l l 1999/10/01 43 60 .06 0 PCT 15 P3 CTS .56 CTS CTS .700 ZRS3C 31 C l l l l 2020/11/01 25 62 .63 95 PCT 16 190 02H -.49 17902.1 17 .31 .22 02H 02H .720 ZYAX2 7 H 336l l 2017/03/01 25 62 1.13 228 PCT 25 Q1 02H -.41 .20 .29 02H 02H .720 ZYAX2 37 H 14l l 2014/03/01 25 62 1.29 0 PCT 26 P55 02H -.70 .21 66 .50 02H HTE .720 ZYAAP 34 H 94l l l l 2010/04/01 42 63 .25 89 PCT 15 P6 CTS .63 SR CTS CTS .720 ZRSNR 46 C 94l l 2010/04/01 42 63 .32 151 PCT 17 P6 CTS .72 SR CTS CTS .720 ZRSNR 46 C 94l l 2010/04/01 42 63 .16 135 PCT 13 P6 HTS .62 SR HTS HTS .720 ZRSNR 53 H 62l l 2007/04/01 42 63 .19 0 PCT 15 P6 CTS .62 SAR CTS CTS .720 ZPS3C 38 C 15l l 2007/04/01 42 63 .34 0 PCT 18 P6 CTS .70 SAR CTS CTS .720 ZPS3C 38 C 15l l 2007/04/01 42 63 .13 0 PCT 12 P6 HTS .64 SAR HTS HTS .720 ZPS3C 39 H 27l l 2004/05/01 42 63 .12 0 PCT 15 P6 HTS .64 SRADABA HTS HTS .700 ZPS3C 14 H 27l l 2004/05/01 42 63 .30 0 PCT 20 P6 CTS .61 SAR CTS CTS .700 ZPS3C 33 C 27l l 2004/05/01 42 63 .21 0 PCT 18 P6 CTS .79 SAR CTS CTS .700 ZPS3C 33 C 27l l 2002/10/01 42 63 .28 0 PCT 11 P3 CTS .61 CTS CTS .700 ZPS3C 1 C 44l l 2002/10/01 42 63 .21 0 PCT 13 P3 HTS .66 SAR HTS HTS .700 ZPS3C 22 H 8l l 1999/10/01 42 63 .13 0 PCT 32 P3 CTS .60 CTS CTS .720 ZRS3C 23 C l l 1999/10/01 42 63 .03 0 PCT 8 P3 HTS .65 HTS HTS .700 ZRS3C 34 H l l 1996/09/01 42 63 1.60 171 PCT 11 1 HTS .65 R96A19 CTE HTE .720 ZBAGB 26 H l l 1996/09/01 42 63 1.49 162 PCT 19 1 CTS .69 R96A19 CTE HTE .720 ZBAGB 26 H l l l l 2020/11/01 15 64 .63 84 PCT 16 202 06H .69 17902.1 18 .29 .14 06H 06H .720 ZYAX2 9 H 152l l 2017/03/01 15 64 .39 149 PCT 15 P1 06H 1.24 .25 .29 01A 06H .720 ZYAX2 37 H 21l l 2014/03/01 15 64 .38 0 PCT 15 P56 06H 1.76 .12 31 .23 06H CTE .720 ZYAAP 31 C 13l l l l 2017/03/01 40 68 .27 156 PCT 14 Q1 HTS .63 .30 .29 01H HTE .720 ZYAX2 9 H 162l l 2014/03/01 40 68 .45 0 PCT 17 P54 CTS .96 01C CTE .720 ZYAAP 21 C 168l l 2013/10/01 40 68 .56 161 PCT 19 Q6 CTS .44 .74 0.45 0.31 FBC CTE .720 ZYAXA 29 C 11l l 2010/04/01 40 68 .31 66 PCT 17 P6 CTS .63 SR CTS CTS .720 ZRSNR 46 C 104l l 2010/04/01 40 68 .31 80 PCT 17 P6 CTS .89 SR CTS CTS .720 ZRSNR 46 C 104l l 2010/04/01 40 68 .32 59 PCT 18 P6 HTS .64 SR HTS HTS .720 ZRSNR 53 H 70l l 2010/04/01 40 68 .24 60 PCT 15 P6 HTS .77 SR HTS HTS .720 ZRSNR 53 H 70l l 2007/04/01 40 68 .28 0 PCT 17 P6 HTS .65 SAR HTS HTS .720 ZPS3C 39 H 28l l 2007/04/01 40 68 .30 0 PCT 17 P6 HTS .73 SAR HTS HTS .720 ZPS3C 39 H 28l l 2004/05/01 40 68 .29 0 PCT 19 P6 HTS .65 SAR HTS HTS .700 ZPS3C 14 H 24l l 2004/05/01 40 68 .26 0 PCT 18 P6 HTS .73 SAR HTS HTS .700 ZPS3C 14 H 24l l 2002/10/01 40 68 .29 0 PCT 16 P3 HTS .68 SAR HTS HTS .700 ZPS3C 22 H 9l l 2002/10/01 40 68 .26 0 PCT 15 P3 HTS .75 SAR HTS HTS .700 ZPS3C 22 H 9l l 1999/10/01 40 68 .07 0 PCT 19 P3 HTS .69 HTS HTS .700 ZRS3C 34 H l l 1999/10/01 40 68 .09 0 PCT 22 P3 HTS .75 HTS HTS .700 ZRS3C 34 H l l 1996/09/01 40 68 1.14 156 PCT 25 1 HTS .58 R96A21 CTE HTE .720 ZBAGB 28 H l l l l 1996/09/01 37 73 .41 144 PCT 38 1 CTS .75 R96A20 CTE HTE .720 ZBAGB 29 H l l l l 1996/09/01 9 74 .75 143 PCT 39 1 02H 44.83 R96A20 CTE HTE .720 ZBAGB 29 H l l 1993/09/01 9 74 .73 142 PCT 37 1 02H 44.85 R93A03 CTE HTE .720 ZBAGB 11 H l l l l 2010/04/01 36 74 .22 156 PCT 15 P6 HTS .66 SR HTS HTS .720 ZRSNR 53 H 69l l 2007/04/01 36 74 .16 0 PCT 13 P6 HTS .62 SAR HTS HTS .720 ZPS3C 39 H 24l l 2004/05/01 36 74 .17 0 PCT 16 P6 HTS .62 SAR HTS HTS .700 ZPS3C 14 H 21l l 2002/10/01 36 74 .17 0 PCT 12 P3 HTS .64 SAR HTS HTS .700 ZPS3C 22 H 10l l 1999/10/01 36 74 .06 0 PCT 16 P3 HTS .60 HTS HTS .700 ZRS3C 34 H l l 1996/09/01 36 74 .19 129 PCT 37 P 1 HTS .57 R96A20 CTE HTE .720 ZBAGB 29 H l l l l 1996/09/01 4 76 .99 167 PCT 12 1 01C 15.49 R96A16 HTE CTE .700 ZBASF 24 C l l l l 2010/04/01 31 80 .26 129 PCT 17 P6 CTS .59 SR CTS CTS .720 ZRSNR 52 C 30l l 2007/04/01 31 80 .29 0 PCT 16 P6 CTS .59 SAR CTS CTS .720 ZPS3C 40 C 17l l 2004/05/01 31 80 .32 0 PCT 19 P6 CTS .59 SAR CTS CTS .700 ZPS3C 33 C 28l l 2002/10/01 31 80 .27 0 PCT 11 P3 CTS .55 CTS CTS .700 ZPS3C 1 C 52l l 1999/10/01 31 80 .07 0 PCT 19 P3 CTS .51 CTS CTS .700 ZRS3C 31 C l l l l 2020/11/01 28 81 1.16 85 PCT 31 86 04H -.71 17902.3 .20 .36 04H 04H .720 ZYAX2 27 H 30l l l l 1987/05/01 8 82 1.16 172 PCT 12 1 01C 25.20 CTE HTE .720 ZBASF 5 H l l l l 2010/04/01 26 84 .26 121 PCT 17 P6 CTS .61 SR CTS CTS .720 ZRSNR 52 C 35l l 2007/04/01 26 84 .24 0 PCT 15 P6 CTS .61 SAR CTS CTS .720 ZPS3C 40 C 16l l 2004/05/01 26 84 .23 0 PCT 19 P6 CTS .61 SAR CTS CTS .700 ZPS3C 33 C 29l l 2002/10/01 26 84 .35 0 PCT 13 P3 CTS .61 CTS CTS .700 ZPS3C 1 C 53l l 1999/10/01 26 84 .05 0 PCT 13 P3 CTS .65 CTS CTS .700 ZRS3C 31 C l l l l 2017/03/01 1 86 .48 82 PCT 18 Q1 CTS .73 .10 .22 01C CTE .720 ZYAX2 3 C 76l l 2014/03/01 1 86 .56 0 PCT 17 P34 CTS .87 01C CTE .720 ZYAAP 25 C 62l l 2013/10/01 1 86 .39 60 PCT 16 Q12 CTS .61 .81 0.37 0.20 FBC CTE .720 ZYAXA 29 C 14l l l l 2020/11/01 23 86 .52 115 PCT 14 10 CTS .49 17902.1 14 .27 .43 01C CTE .720 ZYAX2 4 C 171l l 2017/03/01 23 86 .37 128 PCT 15 P1 CTS .54 .30 .22 01C CTE .720 ZYAX2 4 C 31l l 2010/04/01 23 86 .30 138 PCT 17 P6 CTS .66 SR CTS FBC .720 ZRSNR 52 C 41l l 2010/04/01 23 86 .21 109 PCT 18 P6 CTS 3.05 SR CTS FBC .720 ZRSNR 52 C 41l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
4 ST Max
SG - A Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2007/04/01 23 86 .32 0 PCT 17 P6 CTS .61 SAR CTS CTS .720 ZPS3C 40 C 15l l 2007/04/01 23 86 .16 0 PCT 13 P6 CTS 3.16 SAR CTS CTS .720 ZPS3C 40 C 15l l 2004/05/01 23 86 .34 0 PCT 19 P6 CTS .61 SAR CTS CTS .700 ZPS3C 33 C 30l l 2004/05/01 23 86 .25 0 PCT 18 P6 CTS 3.16 SAR CTS CTS .700 ZPS3C 33 C 30l l 2002/10/01 23 86 .34 0 PCT 13 P3 CTS .62 CTS CTS .700 ZPS3C 1 C 54l l 1999/10/01 23 86 .09 0 PCT 21 P3 CTS .62 CTS CTS .700 ZRS3C 31 C l l l l 2017/03/01 1 87 .21 21 PCT 13 Q1 CTS 1.17 .25 .29 01C CTE .720 ZYAX2 3 C 58l l 2014/03/01 1 87 .25 0 PCT 12 P17 CTS 1.22 01C CTE .720 ZYAAP 25 C 63l l 2013/10/01 1 87 .17 92 PCT 12 Q4 CTS 1.03 1.21 0.30 0.18 FBC CTE .720 ZYAXA 29 C 15l l l l 2020/11/01 11 87 .54 56 PCT 20 98 CTS .07 17902.3 20 .11 .43 01C CTE .720 ZYAX2 3 C 129l l 2017/03/01 11 87 .55 347 PCT 19 Q1 CTS -.05 .15 .22 01C CTE .720 ZYAX2 3 C 35l l l l 2010/04/01 19 87 .29 108 PCT 17 P6 CTS 7.69 SR CTS FBC .720 ZRSNR 50 C 57l l 2007/04/01 19 87 .26 0 PCT 16 P6 CTS 7.69 SAR CTS FBC .720 ZPS3C 38 C 14l l 2004/05/01 19 87 .23 0 PCT 19 P6 CTS 7.62 SAR CTS FBC .700 ZPS3C 33 C 31l l 2002/10/01 19 87 .30 0 PCT 12 P3 CTS 7.62 CTS FBC .700 ZPS3C 1 C 55l l 1999/10/01 19 87 .08 0 PCT 20 P3 CTS 7.62 CTS FBC .700 ZRS3C 31 C l l l l 2017/03/01 18 88 .95 43 PCT 23 Q1 FBH .31 .15 .22 06H HTE .720 ZYAX2 10 H 305l l 2014/03/01 18 88 .34 0 PCT 16 P46 FBH .25 WAR 01H HTE .720 ZYAAP 36 H 103l l 2013/10/01 18 88 .62 78 PCT 20 Q19 FBH .21 .44 0.37 0.23 01H HTE .720 ZYAXA 26 H 43l l l l 2010/04/01 1 89 .26 93 PCT 16 P6 HTS 15.59 HTS FBH .720 ZRSNR 53 H 71l l 2007/04/01 1 89 .18 0 PCT 14 P6 HTS 15.54 SAR HTS FBH .720 ZPS3C 39 H 34l l 2004/05/01 1 89 .19 0 PCT 16 P6 HTS 15.54 SRADABA HTS FBH .700 ZPS3C 14 H 15l l 2002/10/01 1 89 .18 0 PCT 13 P3 HTS 15.54 SAR HTS FBH .700 ZPS3C 22 H 13l l 1999/10/01 1 89 .04 0 PCT 16 P3 HTS 15.55 HTS FBH .700 ZRS3C 46 H l l l l 2010/04/01 11 91 .20 91 PCT 15 P6 CTS .56 SR CTS CTS .720 ZRSNR 52 C 61l l 2010/04/01 11 91 .24 89 PCT 16 P6 CTS .67 SR CTS CTS .720 ZRSNR 52 C 61l l 2007/04/01 11 91 .22 0 PCT 18 P6 CTS .56 SAR CTS CTS .720 ZPS3C 38 C 13l l 2007/04/01 11 91 .26 0 PCT 17 P6 CTS .67 SAR CTS CTS .720 ZPS3C 38 C 13l l 2004/05/01 11 91 .20 0 PCT 18 P6 CTS .52 SAR CTS CTS .700 ZPS3C 33 C 32l l 2004/05/01 11 91 .23 0 PCT 19 P6 CTS .67 SAR CTS CTS .700 ZPS3C 33 C 32l l 2002/10/01 11 91 .30 0 PCT 12 P3 CTS .67 CTS CTS .700 ZPS3C 1 C 56l l 1999/10/01 11 91 .02 0 PCT 21 P3 CTS .68 CTS CTS .700 ZRS3C 30 C l l 1999/10/01 11 91 .05 0 PCT 14 P3 CTS .56 CTS CTS .700 ZRS3C 31 C l l 1999/10/01 11 91 .06 0 PCT 16 P3 CTS .60 CTS CTS .700 ZRS3C 31 C l l 1996/09/01 11 91 1.04 155 PCT 24 1 CTS .47 R96A18 HTE CTE .720 ZBAGB 28 C l l l l 2010/04/01 1 92 .23 53 PCT 15 P6 HTS 10.85 HTS FBH .720 ZRSNR 53 H 73l l l l 2010/04/01 7 92 .18 82 PCT 15 P6 CTS .63 SR CTS CTS .720 ZRSNR 50 C 71l l 2007/04/01 7 92 .20 0 PCT 15 P6 CTS .61 SAR CTS CTS .720 ZPS3C 38 C 12l l 2004/05/01 7 92 .14 0 PCT 17 P6 CTS .61 SAR CTS CTS .700 ZPS3C 33 C 33l l 2002/10/01 7 92 .23 0 PCT 9 P3 CTS .61 CTS CTS .700 ZPS3C 1 C 57l l 1999/10/01 7 92 .07 0 PCT 18 P3 CTS .65 CTS CTS .700 ZRS3C 31 C l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
Tubes: 81 Records: 397 5 ST Max
SG - B Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2010/04/01 1 1 .22 83 PCT 15 P6 CTS 9.13 SR CTS FBC .720 ZRSNR 42 C 8l l 2010/04/01 1 1 .15 109 PCT 18 P6 CTS 12.43 SR CTS FBC .720 ZRSNR 42 C 8l l 2010/04/01 1 1 .53 83 PCT 22 P6 CTS 12.63 SR CTS FBC .720 ZRSNR 42 C 8l l 2010/04/01 1 1 .08 20 PCT 16 P6 CTS 13.12 SR CTS FBC .720 ZRSNR 42 C 8l l 2010/04/01 1 1 .18 68 PCT 18 P6 CTS 14.57 SR CTS FBC .720 ZRSNR 42 C 8l l 2010/04/01 1 1 .20 122 PCT 18 P6 CTS 15.51 SR CTS FBC .720 ZRSNR 42 C 8l l 2007/04/01 1 1 .12 0 PCT 13 P6 CTS 9.13 SAR CTS FBC .720 ZPS3C 62 C 7l l 2007/04/01 1 1 .28 0 PCT 17 P6 CTS 12.10 SAR CTS FBC .720 ZPS3C 62 C 7l l 2007/04/01 1 1 .49 0 PCT 21 P6 CTS 12.63 SAR CTS FBC .720 ZPS3C 62 C 7l l 2007/04/01 1 1 .13 0 PCT 14 P6 CTS 13.10 SAR CTS FBC .720 ZPS3C 62 C 7l l 2007/04/01 1 1 .28 0 PCT 17 P6 CTS 15.15 SAR CTS FBC .720 ZPS3C 62 C 7l l 2004/05/01 1 1 .27 0 PCT 15 P6 CTS 9.62 SAR CTS FBC .700 ZPS3C 34 C 7l l 2004/05/01 1 1 .19 0 PCT 14 P6 CTS 12.71 SAR CTS FBC .700 ZPS3C 34 C 7l l 2004/05/01 1 1 .48 0 PCT 20 P6 CTS 12.75 SAR CTS FBC .700 ZPS3C 34 C 7l l 2004/05/01 1 1 .57 0 PCT 22 P6 CTS 13.10 SAR CTS FBC .700 ZPS3C 34 C 7l l 2004/05/01 1 1 .28 0 PCT 17 P6 CTS 15.08 SAR CTS FBC .700 ZPS3C 34 C 7l l 2002/10/01 1 1 .23 0 PCT 15 P3 CTS 9.62 CTS FBC .700 ZPS3C 4 C 6l l 2002/10/01 1 1 .38 0 PCT 18 P3 CTS 12.71 CTS FBC .700 ZPS3C 4 C 6l l 2002/10/01 1 1 .26 0 PCT 16 P3 CTS 12.75 CTS FBC .700 ZPS3C 4 C 6l l 2002/10/01 1 1 .68 0 PCT 25 P3 CTS 13.10 CTS FBC .700 ZPS3C 4 C 6l l 2002/10/01 1 1 .26 0 PCT 16 P3 CTS 15.26 CTS FBC .700 ZPS3C 4 C 6l l 2001/04/01 1 1 .20 0 PCT 18 P3 CTS 9.62 CTS FBC .700 ZPS3C 42 C 7l l 2001/04/01 1 1 .17 0 PCT 17 P3 CTS 13.07 CTS FBC .700 ZPS3C 42 C 7l l 2001/04/01 1 1 .23 0 PCT 18 P3 CTS 13.10 CTS FBC .700 ZPS3C 42 C 7l l 2001/04/01 1 1 .18 0 PCT 18 P3 CTS 16.20 CTS FBC .700 ZPS3C 42 C 7l l l l 2010/04/01 2 1 .24 132 PCT 13 P6 CTS 5.56 SR CTS FBC .720 ZRSNR 44 C 7l l 2010/04/01 2 1 .20 131 PCT 12 P6 CTS 10.22 SR CTS FBC .720 ZRSNR 44 C 7l l 2010/04/01 2 1 .30 151 PCT 18 P6 CTS 11.63 SR CTS FBC .720 ZRSNR 44 C 7l l 2007/04/01 2 1 .23 0 PCT 15 P6 CTS 5.49 SAR CTS FBC .720 ZPS3C 64 C 8l l 2007/04/01 2 1 .29 0 PCT 17 P6 CTS 10.17 SAR CTS FBC .720 ZPS3C 64 C 8l l 2007/04/01 2 1 .30 0 PCT 17 P6 CTS 11.64 SAR CTS FBC .720 ZPS3C 64 C 8l l 2004/05/01 2 1 .35 0 PCT 17 P6 CTS 10.07 SAR CTS FBC .700 ZPS3C 34 C 8l l 2004/05/01 2 1 .35 0 PCT 17 P6 CTS 11.52 SAR CTS FBC .700 ZPS3C 34 C 8l l 2002/10/01 2 1 .30 0 PCT 17 P3 CTS 10.07 SAR CTS FBC .700 ZPS3C 20 C 6l l 2002/10/01 2 1 .26 0 PCT 16 P3 CTS 11.52 SAR CTS FBC .700 ZPS3C 20 C 6l l l l 2010/04/01 6 1 .24 89 PCT 17 P6 CTS .52 SR CTS CTS .720 ZRSNR 44 C 12l l 2007/04/01 6 1 .23 0 PCT 15 P6 CTS .48 SAR CTS CTS .720 ZPS3C 64 C 6l l 2004/05/01 6 1 .25 0 PCT 15 P6 CTS .49 SAR CTS CTS .700 ZPS3C 34 C 9l l 2002/10/01 6 1 .25 0 PCT 15 P3 CTS .49 SAR CTS CTS .700 ZPS3C 20 C 5l l l l 2010/04/01 7 1 .15 78 PCT 15 P6 CTS .66 SR CTS FBC .720 ZRSNR 44 C 13l l 2010/04/01 7 1 .21 123 PCT 12 P6 CTS 1.18 SR CTS FBC .720 ZRSNR 44 C 13l l 2010/04/01 7 1 .24 129 PCT 13 P6 CTS 12.80 SR CTS FBC .720 ZRSNR 44 C 13l l 2007/04/01 7 1 .14 0 PCT 13 P6 CTS .64 SAR CTS FBC .720 ZPS3C 64 C 7l l 2007/04/01 7 1 .17 0 PCT 13 P6 CTS 1.12 SAR CTS FBC .720 ZPS3C 64 C 7l l 2007/04/01 7 1 .28 0 PCT 16 P6 CTS 12.40 SAR CTS FBC .720 ZPS3C 64 C 7l l 2004/05/01 7 1 .16 0 PCT 13 P6 CTS .63 SAR CTS FBC .700 ZPS3C 34 C 10l l 2004/05/01 7 1 .28 0 PCT 17 P6 CTS 1.14 SAR CTS FBC .700 ZPS3C 34 C 10l l 2004/05/01 7 1 .31 0 PCT 16 P6 CTS 12.47 SAR CTS FBC .700 ZPS3C 34 C 10l l 2002/10/01 7 1 .13 0 PCT 14 P3 CTS .63 CTS FBC .700 ZPS3C 4 C 5l l 2002/10/01 7 1 .24 0 PCT 15 P3 CTS 1.14 CTS FBC .700 ZPS3C 4 C 5l l 2002/10/01 7 1 .39 0 PCT 19 P3 CTS 12.47 CTS FBC .700 ZPS3C 4 C 5l l 2001/04/01 7 1 .29 0 PCT 19 P3 CTS 1.15 CTS CTS .700 ZPS3C 42 C 6l l l l 2010/04/01 11 2 .31 127 PCT 15 P6 CTS .56 SR CTS CTS .720 ZRSNR 44 C 18l l 2007/04/01 11 2 .29 0 PCT 17 P6 CTS .56 SAR CTS CTS .720 ZPS3C 64 C 9l l 2004/05/01 11 2 .37 0 PCT 19 P6 CTS .56 SAR CTS CTS .700 ZPS3C 34 C 11l l 2002/10/01 11 2 .31 0 PCT 17 P3 CTS .48 SAR CTS CTS .700 ZPS3C 20 C 7l l l l 2010/04/01 16 4 .25 60 PCT 19 P6 CTS .50 SR CTS CTS .720 ZRSNR 42 C 53l l 2007/04/01 16 4 .28 0 PCT 17 P6 CTS .50 SAR CTS CTS .720 ZPS3C 62 C 8l l 2004/05/01 16 4 .31 0 PCT 16 P6 CTS .44 SAR CTS CTS .700 ZPS3C 34 C 12l l 2002/10/01 16 4 .25 0 PCT 15 P3 CTS .44 SAR CTS CTS .700 ZPS3C 20 C 8l l l l 2020/11/01 3 5 3.35 115 PCT 38 Q9 CTS .14 11956.2 .18 .36 01C CTE .720 ZYAX2 4 C 28l l 2017/03/01 3 5 3.28 87 PCT 38 Q1 CTS .17 .28 .36 01C CTE .720 ZYAX2 3 C 192l l 2014/03/01 3 5 2.72 0 PCT 35 P52 CTS .08 .11 51 .39 01C CTE .720 ZYAAP 29 C 204l l l l 2013/10/01 7 5 .28 45 PCT 13 P23 HTS .23 0.30 0.27 01H HTE .720 ZYAXA 23 H 132l l 2010/04/01 7 5 .43 82 PCT 21 P6 HTS .20 HR&SR HTS HTS .720 ZRSNR 73 H 4l l l l 2010/04/01 23 7 .27 156 PCT 18 P6 HTS .68 SR HTS HTS .720 ZRSNR 51 H 38l l 2007/04/01 23 7 .21 0 PCT 14 P6 HTS .68 SAR HTS HTS .720 ZPS3C 39 H 28l l 2004/05/01 23 7 .21 0 PCT 14 P6 HTS .68 SAR HTS HTS .700 ZPS3C 23 H 11l l 2002/10/01 23 7 .34 0 PCT 16 P3 HTS .94 SAR HTS HTS .700 ZPS3C 22 H 17l l l l 1993/09/01 9 9 1.31 168 PCT 11 1 CTS 3.73 R93B01 CTE HTE .720 ZBAGB 1 H l l l l 2010/04/01 26 9 .85 64 PCT 19 P6 HTS .62 SR HTS HTS .720 ZRSNR 51 H 37l l 2007/04/01 26 9 .29 0 PCT 19 P6 HTS .62 SAR HTS HTS .720 ZPS3C 39 H 27l l 2004/05/01 26 9 .46 0 PCT 20 P6 HTS .62 SAR HTS HTS .700 ZPS3C 23 H 12l l 2002/10/01 26 9 .38 0 PCT 17 P3 HTS .54 SAR HTS HTS .700 ZPS3C 22 H 16l l l l 2014/03/01 25 11 .35 0 PCT 16 P51 04C .56 04C CTE .720 ZYAAP 33 C 147l l 2013/10/01 25 11 .34 80 PCT 16 Q12 04C -.83 -.65 0.37 0.19 04C 04C .720 ZYAXA 36 C 20l l 2010/04/01 25 11 .68 90 PCT 26 P6 04C -.64 SR 04C 04C .720 ZRSNR 42 C 63l l 2007/04/01 25 11 .63 0 PCT 24 P6 04C -.64 SAR 04C 04C .720 ZPS3C 62 C 12l l 2004/05/01 25 11 .52 0 PCT 23 P6 04C -.59 SRADABA 04C 04C .700 ZPS3C 43 C 7l l l l 2020/11/01 14 13 .44 91 PCT 13 162 HTS .27 17902.1 17 .22 .43 01H HTE .720 ZYAX2 21 H 203l l 2017/03/01 14 13 .52 245 PCT 19 Q1 HTS .16 .20 .29 01H HTE .720 ZYAX2 33 H 137l l 2013/10/01 14 13 .88 77 PCT 23 Q4 HTS .29 0.52 0.37 01H HTE .720 ZYAXA 23 H 133l l l l 2020/11/01 28 14 1.15 87 PCT 21 243 FBC .43 17902.1 20 .58 .43 01C CTE .720 ZYAX2 3 C 186l l 2017/03/01 28 14 .91 63 PCT 21 P1 FBC .58 .25 .27 01C CTE .720 ZYAX2 4 C 51l l l l 2007/04/01 29 14 1.04 0 PCT 31 P6 FBH .46 SAR FBH FBH .720 ZPS3C 39 H 16l l 2004/05/01 29 14 .67 0 PCT 26 P6 FBH .56 SAR FBH FBH .700 ZPS3C 39 H 27l l 2004/05/01 29 14 .79 0 PCT 28 P6 FBH .63 SAR FBH FBH .700 ZPS3C 39 H 27l l l l 2007/04/01 30 14 .18 0 PCT 15 P6 FBH .42 SAR FBH FBH .720 ZPS3C 51 H 38l l 2007/04/01 30 14 .48 0 PCT 22 P6 FBH .44 SAR FBH FBH .720 ZPS3C 51 H 38l l l l 2007/04/01 29 15 1.40 0 PCT 36 P6 FBH .43 SAR FBH FBH .720 ZPS3C 39 H 15l l 2004/05/01 29 15 .57 0 PCT 23 P6 FBH .49 SAR FBH FBH .700 ZPS3C 39 H 26l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
1 ST Max
SG - B Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l l l 2010/04/01 7 16 .26 92 PCT 19 P6 CTS 16.11 SR CTS FBC .720 ZRSNR 42 C 47l l 2007/04/01 7 16 .33 0 PCT 18 P6 CTS 16.11 SAR CTS FBC .720 ZPS3C 62 C 6l l 2004/05/01 7 16 .33 0 PCT 17 P6 CTS 15.94 SAR CTS FBC .700 ZPS3C 34 C 15l l 2002/10/01 7 16 .29 0 PCT 17 P3 CTS 15.94 CTS FBC .700 ZPS3C 4 C 7l l l l 2020/11/01 2 17 .64 137 PCT 20 Q3 06C -.52 11956.2 .22 .29 06C 06H .700 ZYAX3 30 H 85l l l l 2017/03/01 21 17 .95 105 PCT 23 Q1 02H -.24 WAR .20 .22 02H 02H .720 ZYAX2 25 H 44l l 2014/03/01 21 17 .83 0 PCT 20 P8 02H -.54 WAR 02H HTE .720 ZYAAP 34 H 25l l 2013/10/01 21 17 .72 98 PCT 19 P22 02H -.46 0.37 0.29 02H 02H .720 ZYAXA 23 H 130l l l l 2007/04/01 33 17 .54 0 PCT 20 P6 FBH .72 SAR FBH FBH .720 ZPS3C 37 H 55l l l l 2004/05/01 34 18 .53 0 PCT 22 P6 FBH .60 SAR FBH FBH .700 ZPS3C 23 H 13l l 2002/10/01 34 18 .53 0 PCT 20 P3 FBH .60 SAR FBH FBH .700 ZPS3C 22 H 11l l l l 2010/04/01 37 20 .22 83 PCT 13 P6 CTS .61 SR CTS CTS .720 ZRSNR 44 C 97l l 2010/04/01 37 20 .22 96 PCT 13 P6 CTS .63 SR CTS CTS .720 ZRSNR 44 C 97l l 2010/04/01 37 20 .77 118 PCT 18 P6 HTS .60 SR HTS HTS .720 ZRSNR 51 H 36l l 2007/04/01 37 20 .35 0 PCT 17 P6 HTS .60 SAR HTS HTS .720 ZPS3C 39 H 10l l 2007/04/01 37 20 .21 0 PCT 15 P6 CTS .51 SAR CTS CTS .720 ZPS3C 64 C 10l l 2007/04/01 37 20 .21 0 PCT 15 P6 CTS .53 SAR CTS CTS .720 ZPS3C 64 C 10l l 2004/05/01 37 20 .32 0 PCT 17 P6 HTS .60 SAR HTS HTS .700 ZPS3C 23 H 16l l 2004/05/01 37 20 .24 0 PCT 16 P6 CTS .51 SAR CTS CTS .700 ZPS3C 34 C 22l l 2004/05/01 37 20 .25 0 PCT 17 P6 CTS .53 SAR CTS CTS .700 ZPS3C 34 C 22l l 2002/10/01 37 20 .37 0 PCT 20 P3 HTS .60 SAR HTS HTS .700 ZPS3C 24 H 5l l l l 2014/03/01 1 21 1.08 0 PCT 25 P39 04C -.64 WAR 04C CTE .720 ZYAAP 51 C 7l l 2013/10/01 1 21 1.06 57 PCT 24 Q5 04C -.81 -.58 0.45 0.23 04C 04C .720 ZYAXA 36 C 14l l 2010/04/01 1 21 .72 121 PCT 29 P6 04C -.59 SR 04C 04C .720 ZRSNR 64 C 69l l l l 1987/05/01 14 22 .97 147 PCT 33 1 03H 15.10 CTE HTE .720 ZBASF 5 H l l l l 2020/11/01 23 22 .28 70 PCT 12 P4 02A -.05 WAR CTE HTE .720 ZBAHS 6 H 12l l l l 2020/11/01 30 24 .23 29 PCT 11 P4 02A -.07 WAR CTE HTE .720 ZBAHS 6 H 31l l l l 2020/11/01 36 24 .23 69 PCT 11 P4 02A -.02 WAR CTE HTE .720 ZBAHS 6 H 28l l 2020/11/01 36 24 .22 102 PCT 10 P4 04A -.06 WAR CTE HTE .720 ZBAHS 6 H 28l l l l 1993/09/01 10 25 .59 168 PCT 11 1 HTS 5.57 R93B01 CTE HTE .720 ZBAGB 3 H l l l l 2010/04/01 40 25 .51 115 PCT 20 P6 CTS .64 SR CTS CTS .720 ZRSNR 44 C 105l l 2010/04/01 40 25 .16 59 PCT 11 P6 CTS .65 SR CTS CTS .720 ZRSNR 44 C 105l l 2007/04/01 40 25 .56 0 PCT 22 P6 CTS .51 SAR CTS CTS .720 ZPS3C 64 C 11l l 2007/04/01 40 25 .42 0 PCT 20 P6 CTS .53 SAR CTS CTS .720 ZPS3C 64 C 11l l 2004/05/01 40 25 .22 0 PCT 16 P6 CTS .53 SAR CTS CTS .700 ZPS3C 34 C 23l l 2004/05/01 40 25 .50 0 PCT 22 P6 CTS .55 SAR CTS CTS .700 ZPS3C 34 C 23l l 2002/10/01 40 25 .47 0 PCT 21 P3 CTS .51 CTS CTS .700 ZPS3C 4 C 9l l 2001/04/01 40 25 .41 0 PCT 21 P3 CTS .59 CTS CTS .700 ZPS3C 58 C 6l l l l 2020/11/01 17 26 .37 124 PCT 15 P4 02A .02 WAR CTE HTE .720 ZBAHS 4 H 100l l 2017/03/01 17 26 .26 113 PCT 12 P4 02A .07 WAR CTE HTE .720 ZBAHS 4 H 160l l l l 1993/09/01 25 26 1.37 157 PCT 23 1 04H 46.13 R93B01 CTE HTE .720 ZBAGB 3 H l l 1993/09/01 25 26 3.93 173 PCT 5 1 04C 17.02 R93B01 CTE HTE .720 ZBAGB 3 H l l 1993/09/01 25 26 2.51 166 PCT 13 1 03C 41.26 R93B01 CTE HTE .720 ZBAGB 3 H l l 1992/04/01 25 26 1.35 156 PCT 24 1 04H 46.63 R92B01 CTE HTE .720 ZBAGB 4 H l l 1992/04/01 25 26 4.36 172 PCT 6 1 04C 17.00 R92B01 CTE HTE .720 ZBAGB 4 H l l 1992/04/01 25 26 2.80 163 PCT 17 1 03C 40.63 R92B01 CTE HTE .720 ZBAGB 4 H l l 1990/10/01 25 26 1.50 152 PCT 26 1 04H 46.00 CTE HTE .720 ZBAGB 5 H l l 1990/10/01 25 26 2.80 160 PCT 17 1 03C 41.20 CTE HTE .720 ZBAGB 5 H l l l l 2010/04/01 40 26 .16 107 PCT 11 P6 CTS .43 SR CTS CTS .720 ZRSNR 44 C 106l l 2007/04/01 40 26 .26 0 PCT 16 P6 CTS .51 SAR CTS CTS .720 ZPS3C 64 C 12l l 2004/05/01 40 26 .32 0 PCT 18 P6 CTS .51 SAR CTS CTS .700 ZPS3C 34 C 24l l l l 2002/10/01 1 27 1.39 0 PCT 41 P3 CTS 16.33 SAR CTS 01C .700 ZPS3C 20 C 9l l l l 2020/11/01 41 28 .59 128 PCT 19 Q17 03H -.51 11956.2 .36 .29 03H 03H .720 ZYAX2 21 H 380l l 2017/03/01 41 28 .51 232 PCT 18 Q1 03H -.22 WAR .28 .22 03H 03H .720 ZYAX2 25 H 26l l 2013/10/01 41 28 .58 60 PCT 19 Q5 03H -.47 0.45 0.23 03H 03H .720 ZYAXA 23 H 111l l l l 1993/09/01 34 30 .67 164 PCT 14 1 HTS 1.80 R93B01 CTE HTE .720 ZBAGB 4 H l l 1992/04/01 34 30 .85 161 PCT 19 1 HTS 1.93 R92B01 CTE HTE .720 ZBAGB 4 H l l l l 2010/04/01 35 30 1.29 95 PCT 40 P6 FBC .47 SR FBC FBC .720 ZRSNR 64 C 12l l l l 2010/04/01 36 30 1.33 88 PCT 40 P6 FBC .45 SR FBC FBC .720 ZRSNR 64 C 13l l l l 2010/04/01 38 30 .66 92 PCT 27 P6 FBC .42 SR FBC FBC .720 ZRSNR 64 C 14l l l l 2010/04/01 39 30 .65 90 PCT 27 P6 FBC .43 SR FBC FBC .720 ZRSNR 64 C 15l l l l 2010/04/01 40 30 .31 160 PCT 9 P6 02A .00 SR HTE CTE .720 CBACC 50 C 18l l 2010/04/01 40 30 2.78 87 PCT 60 P6 FBC .52 SR FBC FBC .720 ZRSNR 64 C 16l l l l 2020/11/01 41 30 .21 108 PCT 10 P4 02A .03 WAR CTE HTE .720 ZBAHS 4 H 38l l 2017/03/01 41 30 .19 76 PCT 9 P4 02A .00 WAR CTE HTE .720 ZBAHS 6 H 37l l 2014/03/01 41 30 .41 0 PCT 11 P2 02A .00 WAR CTE HTE .720 CBACC 32 H 5l l 2013/10/01 41 30 .47 68 PCT 11 P2 02A .04 HTE CTE .720 ZBAGB 20 C 14l l 1993/09/01 41 30 .33 140 PCT 39 1 05H 20.23 R93B01 CTE HTE .720 ZBAGB 4 H l l l l 2020/11/01 42 30 .39 139 PCT 17 146 CTS .73 17902.3 21 .33 .43 01C CTE .720 ZYAX2 6 C 131l l 2020/11/01 42 30 .48 129 PCT 14 190 HTS .66 17902.3 18 .36 .29 01H HTE .720 ZYAX2 21 H 375l l 2017/03/01 42 30 .47 145 PCT 18 Q1 CTS .45 .13 .22 01C CTE .720 ZYAX2 3 C 123l l 2017/03/01 42 30 .63 142 PCT 20 Q1 HTS .60 .24 .26 01H HTE .720 ZYAX2 25 H 25l l l l 2007/04/01 4 32 .41 0 PCT 20 P6 CTS 3.11 SAR CTS CTS .720 ZPS3C 62 C 19l l 2007/04/01 4 32 .29 0 PCT 18 P6 CTS 6.12 SAR CTS CTS .720 ZPS3C 62 C 19l l l l 1993/09/01 18 32 1.43 159 PCT 25 2 04H 19.01 R93B01 CTE HTE .720 ZBAGB 4 H l l l l 2004/05/01 24 33 .42 0 PCT 20 P6 HTS .19 SAR HTS HTS .700 ZPS3C 45 H 10l l l l 1993/09/01 36 33 .59 157 PCT 24 1 05C 46.46 R93B02 CTE HTE .720 ZBAGB 5 H l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
2 ST Max
SG - B Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l l l 2017/03/01 38 33 2.01 319 PCT 31 Q1 HTS .13 .23 .29 01H HTE .720 ZYAX2 25 H 79l l 2014/03/01 38 33 2.19 0 PCT 33 P48 HTS .18 01H HTE .720 ZYAAP 18 H 86l l 2013/10/01 38 33 2.43 93 PCT 34 Q4 HTS .12 0.59 0.31 01H HTE .720 ZYAXA 23 H 19l l l l 2020/11/01 43 33 .36 132 PCT 16 134 HTS .73 17902.3 16 .22 .29 01H HTE .720 ZYAX2 21 H 410l l 2017/03/01 43 33 .48 155 PCT 16 P29 HTS .70 .25 .28 01H HTE .720 ZYAX2 24 H 8l l 2010/04/01 43 33 .26 127 PCT 14 P6 CTS .67 SR CTS CTS .720 ZRSNR 44 C 115l l l l 1993/09/01 42 34 1.75 173 PCT 6 1 05C 45.74 R93B02 CTE HTE .720 ZBAGB 5 H l l l l 2020/11/01 35 36 .25 98 PCT 11 P4 03A -.32 WAR CTE HTE .720 ZBAHS 1 H 157l l 2017/03/01 35 36 .23 104 PCT 11 P4 03A -.19 WAR CTE HTE .720 ZBAHS 6 H 118l l 2014/03/01 35 36 .33 0 PCT 9 P2 03A .00 WAR CTE HTE .720 CBACC 32 H 7l l 2013/10/01 35 36 .57 101 PCT 13 P2 03A -.24 HTE CTE .720 ZBAGB 20 C 12l l 2010/04/01 35 36 .54 145 PCT 13 P2 03A .00 SR HTE CTE .720 NBAZC 96 C 12l l l l 2020/11/01 44 36 .46 99 PCT 18 86 CTS .75 17902.3 16 .24 .29 01C CTE .720 ZYAX2 6 C 154l l 2020/11/01 44 36 .48 114 PCT 19 170 CTS .80 17902.3 20 .29 .58 01C CTE .720 ZYAX2 6 C 154l l 2020/11/01 44 36 .44 157 PCT 13 46 HTS .71 17902.1 14 .31 .43 01H HTE .720 ZYAX2 21 H 355l l 2020/11/01 44 36 .38 104 PCT 12 162 HTS .74 17902.1 14 .22 .43 01H HTE .720 ZYAX2 21 H 355l l 2017/03/01 44 36 .18 132 PCT 12 Q1 CTS .50 .30 .14 01C CTE .720 ZYAX2 3 C 146l l 2017/03/01 44 36 .42 95 PCT 17 Q1 CTS .54 .30 .14 01C CTE .720 ZYAX2 3 C 146l l 2017/03/01 44 36 .52 158 PCT 19 Q1 HTS .62 .24 .26 01H HTE .720 ZYAX2 25 H 15l l 2017/03/01 44 36 .28 163 PCT 15 Q1 HTS .64 .23 .26 01H HTE .720 ZYAX2 25 H 15l l l l 2020/11/01 44 38 .17 169 PCT 8 P4 04A -.15 WAR CTE HTE .720 ZBAHS 3 H 92l l 2017/03/01 44 38 .33 145 PCT 14 P4 04A -.16 WAR CTE HTE .720 ZBAHS 5 H 149l l 2014/03/01 44 38 .41 0 PCT 11 P2 04A .00 WAR CTE HTE .720 CBACC 32 H 8l l 2013/10/01 44 38 .47 156 PCT 11 P2 04A -.11 HTE CTE .720 ZBAGB 20 C 11l l l l 1993/09/01 32 39 .32 152 PCT 29 1 05H 46.83 R93B02 CTE HTE .720 ZBAGB 5 H l l l l 2017/03/01 2 41 .60 56 PCT 18 P1 CTS .99 .30 .22 01C CTE .720 ZYAX2 4 C 300l l 2014/03/01 2 41 .59 108 PCT 18 P3 CTS 1.09 01C CTE .720 ZYAAP 29 C 75l l 2013/10/01 2 41 .21 120 PCT 13 Q3 CTS .72 .86 0.37 0.14 01C CTE .720 ZYAXA 36 C 13l l 2010/04/01 2 41 .47 88 PCT 22 P6 CTS 1.19 SR CTS CTS .720 ZRSNR 38 C 99l l 2007/04/01 2 41 .31 0 PCT 18 P6 CTS 1.19 SAR CTS CTS .720 ZPS3C 62 C 28l l l l 2010/04/01 2 42 .54 111 PCT 24 P6 CTS 1.46 SR CTS CTS .720 ZRSNR 36 C 21l l 2007/04/01 2 42 .77 0 PCT 27 P6 CTS 1.59 SAR CTS CTS .720 ZPS3C 62 C 27l l 2004/05/01 2 42 .77 0 PCT 26 P6 CTS 1.50 SAR CTS CTS .700 ZPS3C 34 C 42l l 2002/10/01 2 42 .57 0 PCT 24 P3 CTS 1.50 SAR CTS CTS .700 ZPS3C 20 C 10l l l l 2017/03/01 3 43 .41 244 PCT 17 Q1 CTS .70 .23 .22 01C CTE .720 ZYAX2 3 C 285l l 2014/03/01 3 43 .51 124 PCT 17 P20 CTS .91 01C CTE .720 ZYAAP 31 C 75l l 2013/10/01 3 43 .31 113 PCT 15 Q13 CTS .68 .88 0.30 0.20 CTS CTE .720 ZYAXA 36 C 11l l 2010/04/01 3 43 .42 144 PCT 21 P6 CTS 1.38 SR CTS CTS .720 ZRSNR 64 C 21l l l l 2014/03/01 4 43 1.25 0 PCT 26 P49 03C -.35 WAR 03C CTE .720 ZYAAP 51 C 8l l 2013/10/01 4 43 .96 61 PCT 23 Q19 03C -.76 -.55 0.45 0.21 03C 03C .720 ZYAXA 36 C 12l l 2010/04/01 4 43 .62 90 PCT 26 P6 03C -.62 SR 03C 03C .720 ZRSNR 64 C 22l l l l 2002/10/01 34 43 .91 0 PCT 20 P5 HTS .01 HTS HTS .700 ZPS3C 25 H 5l l l l 2007/04/01 3 44 1.04 0 PCT 32 P6 HTS .24 SAR HTS HTS .720 ZPS3C 57 H 40l l 2007/04/01 3 44 .56 0 PCT 23 P6 HTS .41 SAR HTS HTS .720 ZPS3C 57 H 40l l l l 2017/03/01 34 44 .82 39 PCT 22 Q1 HTS -.05 .20 .29 01H HTE .720 ZYAX2 24 H 132l l 2013/10/01 34 44 1.20 106 PCT 26 Q5 HTS .04 0.52 0.23 01H HTE .720 ZYAXA 23 H 18l l 2010/04/01 34 44 .70 111 PCT 28 P6 HTS .07 SR HTS HTS .720 ZRSNR 51 H 27l l 2007/04/01 34 44 .80 0 PCT 26 P6 HTS .07 SAR HTS HTS .720 ZPS3C 39 H 84l l 2004/05/01 34 44 .71 0 PCT 26 P6 HTS .07 SAR HTS HTS .700 ZPS3C 45 H 9l l l l 2010/04/01 3 45 .36 64 PCT 19 P6 CTS 1.42 SR CTS CTS .720 ZRSNR 36 C 32l l 2007/04/01 3 45 .35 0 PCT 19 P6 CTS 1.42 SAR CTS CTS .720 ZPS3C 64 C 23l l l l 2020/11/01 16 45 .84 88 PCT 26 122 02H -.52 17902.3 25 .13 .29 02H 02H .720 ZYAX2 22 H 393l l 2017/03/01 16 45 .86 119 PCT 22 Q1 02H -.24 WAR .18 .29 02H 02H .720 ZYAX2 24 H 53l l l l 2017/03/01 10 46 .69 58 PCT 21 Q1 HTS 2.60 .33 .43 01H HTE .720 ZYAX2 36 H 85l l 2013/10/01 10 46 .74 86 PCT 21 Q12 HTS 3.21 0.52 0.33 01H HTE .720 ZYAXA 23 H 17l l 2010/04/01 10 46 .37 82 PCT 19 P6 HTS 3.16 SR HTS 01H .720 ZRSNR 71 H 7l l l l 2017/03/01 16 46 1.15 72 PCT 25 Q1 02H -.19 WAR .18 .22 02H 02H .720 ZYAX2 25 H 45l l 2014/03/01 16 46 .88 0 PCT 23 P53 02H -.61 WAR 02H HTE .720 ZYAAP 34 H 24l l 2013/10/01 16 46 1.12 101 PCT 25 Q4 02H -.62 0.52 0.23 02H 01H .720 ZYAXA 23 H 123l l l l 1993/09/01 19 46 1.36 167 PCT 15 1 CTS 13.57 R93B02 CTE HTE .720 ZBAGB 6 H l l l l 2013/10/01 4 47 .20 111 PCT 13 Q16 CTS .70 .84 0.30 0.14 CTS CTE .720 ZYAXA 36 C 7l l 2010/04/01 4 47 .29 91 PCT 17 P6 CTS 1.42 SR CTS CTS .720 ZRSNR 36 C 34l l 2010/04/01 4 47 .30 113 PCT 17 P6 CTS 1.44 SR CTS CTS .720 ZRSNR 36 C 34l l 2007/04/01 4 47 .25 0 PCT 16 P6 CTS 1.42 SAR CTS CTS .720 ZPS3C 64 C 22l l 2007/04/01 4 47 .25 0 PCT 16 P6 CTS 1.44 SAR CTS CTS .720 ZPS3C 64 C 22l l 2004/05/01 4 47 .23 0 PCT 14 P6 CTS 1.42 SAR CTS CTS .700 ZPS3C 34 C 41l l 2004/05/01 4 47 .25 0 PCT 15 P6 CTS 1.44 SAR CTS CTS .700 ZPS3C 34 C 41l l l l 2010/04/01 4 48 .33 59 PCT 19 P6 CTS 1.59 SR CTS 01C .720 ZRSNR 64 C 20l l 2010/04/01 4 48 .77 91 PCT 30 P6 CTS 3.34 SR CTS 01C .720 ZRSNR 64 C 20l l 2007/04/01 4 48 .31 0 PCT 17 P6 CTS 1.59 SAR CTS CTS .720 ZPS3C 62 C 26l l 2007/04/01 4 48 .86 0 PCT 28 P6 CTS 3.27 SAR CTS CTS .720 ZPS3C 62 C 26l l 2004/05/01 4 48 .35 0 PCT 17 P6 CTS 1.59 SAR CTS CTS .700 ZPS3C 34 C 38l l 2004/05/01 4 48 .82 0 PCT 27 P6 CTS 3.27 SAR CTS CTS .700 ZPS3C 34 C 38l l l l 2017/03/01 5 48 .41 129 PCT 15 P5 03H 50.98 .31 .22 04H 03H .720 ZYAX2 45 H 14l l 2014/03/01 5 48 .36 0 PCT 16 P53 03H 50.78 04H HTE .720 ZYAAP 36 H 6l l 2013/10/01 5 48 .34 111 PCT 16 Q13 03H 51.00 0.45 0.27 04H 03H .720 ZYAXA 23 H 122l l 2013/10/01 5 48 .30 136 PCT 15 Q9 CTS .94 1.14 0.37 0.20 CTS CTE .720 ZYAXA 36 C 27l l 2010/04/01 5 48 .79 104 PCT 28 P6 CTS 1.53 SR CTS CTS .720 ZRSNR 34 C 36l l 2007/04/01 5 48 .79 0 PCT 28 P6 CTS 1.67 SAR CTS CTS .720 ZPS3C 64 C 21l l 2004/05/01 5 48 .81 0 PCT 27 P6 CTS 1.71 SAR CTS CTS .700 ZPS3C 34 C 39l l 2002/10/01 5 48 .66 0 PCT 22 P3 CTS 1.46 CTS 01C .700 ZPS3C 4 C 23l l 2002/10/01 5 48 .76 0 PCT 27 P3 CTS 1.71 CTS 01C .700 ZPS3C 4 C 23l l 2001/04/01 5 48 .88 0 PCT 28 P3 CTS 1.46 CTS CTS .700 ZPS3C 40 C 10l l 2001/04/01 5 48 1.05 0 PCT 29 P3 CTS 1.71 CTS CTS .700 ZPS3C 52 C 8l l l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
3 ST Max
SG - B Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2010/04/01 4 49 .33 61 PCT 18 P6 CTS 1.50 SR CTS CTS .720 ZRSNR 36 C 36l l 2007/04/01 4 49 .43 0 PCT 20 P6 CTS 1.50 SAR CTS CTS .720 ZPS3C 62 C 25l l 2004/05/01 4 49 .35 0 PCT 17 P6 CTS 1.53 SAR CTS CTS .700 ZPS3C 34 C 37l l l l 2013/10/01 5 49 .51 67 PCT 18 Q9 CTS .85 1.05 0.37 0.20 CTS CTE .720 ZYAXA 36 C 26l l 2010/04/01 5 49 .72 49 PCT 28 P6 CTS 1.69 SR CTS CTS .720 ZRSNR 36 C 35l l 2007/04/01 5 49 .69 0 PCT 27 P6 CTS 1.69 SAR CTS CTS .720 ZPS3C 64 C 20l l 2004/05/01 5 49 .73 0 PCT 26 P6 CTS 1.69 SAR CTS CTS .700 ZPS3C 34 C 36l l 2002/10/01 5 49 .81 0 PCT 28 P3 CTS 1.78 CTS 01C .700 ZPS3C 4 C 21l l 2001/04/01 5 49 .76 0 PCT 27 P3 CTS 1.78 CTS CTS .700 ZPS3C 40 C 9l l 2001/04/01 5 49 .79 0 PCT 24 P3 CTS 1.77 CTS CTS .700 ZPS3C 52 C 9l l l l 2010/04/01 4 50 .33 50 PCT 19 P6 CTS 1.88 SR CTS CTS .720 ZRSNR 34 C 37l l 2007/04/01 4 50 .23 0 PCT 16 P6 CTS 1.76 SAR CTS CTS .720 ZPS3C 62 C 24l l 2004/05/01 4 50 .27 0 PCT 15 P6 CTS 1.76 SAR CTS CTS .700 ZPS3C 34 C 40l l l l 2020/11/01 34 52 .33 75 PCT 15 86 HTS .41 17902.3 17 .24 .29 01H HTE .720 ZYAX2 23 H 66l l 2017/03/01 34 52 .53 53 PCT 19 Q10 HTS -.05 .15 .22 01H HTE .720 ZYAX2 30 H 81l l 2013/10/01 34 52 .79 65 PCT 22 Q6 HTS .02 0.45 0.23 01H HTE .720 ZYAXA 23 H 16l l l l 2020/11/01 10 53 .85 80 PCT 18 243 04A .55 17902.1 17 .47 .43 04A 04A .720 ZYAX2 32 H 17l l 2017/03/01 10 53 .33 128 PCT 14 P4 04A 1.48 WAR CTE HTE .720 ZBAHS 18 H 50l l 2014/03/01 10 53 .61 0 PCT 15 P2 04A .70 .97 WAR CTE HTE .720 CBACC 32 H 10l l 2013/10/01 10 53 .65 117 PCT 18 P24 04A .70 .97 0.22 0.27 06C 06H .720 ZYAXA 27 H 11l l l l 2013/10/01 11 53 .56 89 PCT 19 Q16 CTS .76 1.10 0.45 0.35 CTS CTE .720 ZYAXA 36 C 25l l 2010/04/01 11 53 .65 102 PCT 26 P6 CTS 1.27 SR CTS CTS .720 ZRSNR 36 C 45l l 2007/04/01 11 53 .73 0 PCT 26 P6 CTS 1.27 SAR CTS CTS .720 ZPS3C 62 C 22l l 2004/05/01 11 53 .69 0 PCT 25 P6 CTS 1.27 SAR CTS CTS .700 ZPS3C 34 C 34l l l l 2020/11/01 30 58 .77 79 PCT 24 218 02H -.69 17902.3 .27 .43 02H 02H .720 ZYAX2 27 H 53l l l l 2014/03/01 43 60 .33 0 PCT 15 P46 CTS .90 01C CTE .720 ZYAAP 41 C 9l l 2010/04/01 43 60 .33 147 PCT 18 P6 CTS .59 SR CTS CTS .720 ZRSNR 38 C 67l l 2007/04/01 43 60 .29 0 PCT 18 P6 CTS .58 SAR CTS CTS .720 ZPS3C 66 C 38l l l l 2014/03/01 34 61 .80 0 PCT 20 P5 05C -1.07 05C CTE .720 ZYAAP 43 C 53l l 2013/10/01 34 61 .72 86 PCT 21 Q14 05C -1.06 -.88 0.37 0.18 05C 05C .720 ZYAXA 36 C 22l l 2010/04/01 34 61 .45 120 PCT 22 P6 05C -.86 SR 05C 05C .720 ZRSNR 98 C 18l l l l 1993/09/01 36 62 .35 143 PCT 37 1 02C 12.24 R93B03 CTE HTE .720 ZBAGB 10 H l l l l 2010/04/01 28 63 3.04 91 PCT 63 P6 02H -.58 SR 02H 02H .720 ZRSNR 65 H 17l l l l 2002/10/01 24 65 1.05 0 PCT 30 P3 02H .36 SAR 02H 02H .700 ZPS3C 22 H 14l l l l 2013/10/01 27 65 .33 122 PCT 15 Q15 03H .08 0.37 0.27 03H 03H .720 ZYAXA 23 H 33l l 2010/04/01 27 65 .46 76 PCT 23 P6 03H .07 SR 03H 03H .720 ZRSNR 51 H 29l l 2007/04/01 27 65 .44 0 PCT 19 P6 03H .08 SAR 03H 03H .720 ZPS3C 39 H 99l l 2004/05/01 27 65 .35 0 PCT 18 P6 03H .08 SAR 03H 03H .700 ZPS3C 39 H 28l l l l 2007/04/01 1 67 .45 0 PCT 25 P8 06C -.54 SAR 06C 06C .720 ZPS3C 62 C 34l l 2007/04/01 1 67 .44 0 PCT 24 P8 06C .61 SAR 06C 06C .720 ZPS3C 62 C 34l l 2004/05/01 1 67 .37 0 PCT 18 P6 06C -.62 SAR 06C 06C .700 ZPS3C 34 C 31l l 2004/05/01 1 67 .33 0 PCT 17 P6 06C .56 SAR 06C 06C .700 ZPS3C 34 C 31l l 2004/05/01 1 67 .18 0 PCT 4 P8 06C -.56 SAR 06C 06C .700 ZPS3C 42 C 9l l 2004/05/01 1 67 .12 0 PCT 2 P8 06C .58 SAR 06C 06C .700 ZPS3C 42 C 9l l 2002/10/01 1 67 .49 0 PCT 22 P3 06C -.53 SAR 06C 06C .700 ZPS3C 20 C 12l l 2002/10/01 1 67 .37 0 PCT 10 P6 06C -.62 06C 06C .700 ZPS3C 21 C 6l l 2002/10/01 1 67 .26 0 PCT 7 P6 06C .56 06C 06C .700 ZPS3C 21 C 6l l l l 2010/04/01 40 67 .14 103 PCT 13 P6 CTS .54 SR CTS CTS .720 ZRSNR 38 C 53l l 2007/04/01 40 67 .15 0 PCT 13 P6 CTS .52 SAR CTS CTS .720 ZPS3C 62 C 44l l 2004/05/01 40 67 .19 0 PCT 13 P6 CTS .41 SAR CTS CTS .700 ZPS3C 34 C 64l l l l 2010/04/01 40 68 .31 104 PCT 18 P6 CTS .63 SR CTS CTS .720 ZRSNR 38 C 54l l 2007/04/01 40 68 .36 0 PCT 18 P6 CTS .51 SAR CTS CTS .720 ZPS3C 62 C 43l l 2004/05/01 40 68 .37 0 PCT 18 P6 CTS .63 SAR CTS CTS .700 ZPS3C 34 C 65l l l l 2020/11/01 14 69 .63 90 PCT 16 202 03A 2.13 17902.1 .31 .29 04A 03A .720 ZYAX2 28 H 52l l l l 2004/05/01 23 71 2.88 0 PCT 55 P6 04H -.03 SAR .39 41 04H 04H .700 ZPS3C 4 H 17l l l l 2004/05/01 23 72 5.69 0 PCT 76 P6 04H -.34 SAR 04H 04H .700 ZPS3C 4 H 20l l l l 2010/04/01 37 72 .45 154 PCT 12 P6 01A .00 SR HTE CTE .720 CBACC 50 C 21l l 2010/04/01 37 72 .38 171 PCT 11 P6 03A .00 SR HTE CTE .720 CBACC 50 C 21l l l l 2020/11/01 28 73 .79 57 PCT 18 243 06H 1.98 17902.1 .31 .43 06H 06H .720 ZYAX2 26 H 62l l l l 2017/03/01 37 73 .68 141 PCT 19 P1 CTS .60 .36 .36 01C CTE .720 ZYAX2 6 C 92l l 2017/03/01 37 73 3.61 252 PCT 40 Q1 05H -.49 WAR .30 .29 05H 05H .720 ZYAX2 28 H 31l l l l 2020/11/01 35 74 .22 82 PCT 10 P4 03A -.03 WAR CTE HTE .720 ZBAHS 10 H 36l l l l 2020/11/01 15 75 .65 97 PCT 16 243 02H -.57 17902.1 .27 .29 02H 02H .720 ZYAX2 28 H 34l l l l 2020/11/01 34 76 .40 133 PCT 17 38 CTS 1.98 17902.3 16 .33 .43 01C CTE .720 ZYAX2 8 C 180l l 2017/03/01 34 76 .45 132 PCT 16 P29 CTS 1.79 .33 .22 01C CTE .720 ZYAX2 6 C 110l l 2010/04/01 34 76 .37 149 PCT 18 P6 CTS 1.92 SR CTS FBC .720 ZRSNR 40 C 36l l 2007/04/01 34 76 .44 0 PCT 21 P6 CTS 1.83 SAR CTS CTS .720 ZPS3C 66 C 39l l l l 2020/11/01 30 77 .24 59 PCT 11 P4 02A -.06 WAR CTE HTE .720 ZBAHS 10 H 72l l l l 2010/04/01 33 78 .37 64 PCT 19 P6 CTS .61 SR CTS CTS .720 ZRSNR 38 C 34l l 2010/04/01 33 78 .37 114 PCT 19 P6 CTS .68 SR CTS CTS .720 ZRSNR 38 C 34l l 2007/04/01 33 78 .29 0 PCT 16 P6 CTS .63 SAR CTS CTS .720 ZPS3C 62 C 41l l 2007/04/01 33 78 .36 0 PCT 18 P6 CTS .64 SAR CTS CTS .720 ZPS3C 62 C 41l l 2004/05/01 33 78 .34 0 PCT 17 P6 CTS .62 SAR CTS CTS .700 ZPS3C 34 C 66l l 2002/10/01 33 78 .38 0 PCT 18 P3 CTS .62 CTS CTS .700 ZPS3C 4 C 16l l 2001/04/01 33 78 .31 0 PCT 20 P3 CTS .62 CTS CTS .700 ZPS3C 40 C 6l l 2001/04/01 33 78 .30 0 PCT 20 P3 CTS .63 CTS CTS .700 ZPS3C 40 C 6l l l l 2020/11/01 5 81 .55 92 PCT 15 82 03H -.65 17902.1 .33 .29 03H 03H .720 ZYAX2 28 H 43l l l l 2020/11/01 16 82 .40 119 PCT 17 74 05C -.55 17902.3 .20 .43 05C 05C .720 ZYAX2 6 C 358l l l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
4 ST Max
SG - B Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2010/04/01 26 84 .29 91 PCT 17 P6 CTS .55 SR CTS CTS .720 ZRSNR 40 C 21l l 2010/04/01 26 84 .39 120 PCT 19 P6 CTS .67 SR CTS CTS .720 ZRSNR 40 C 21l l 2007/04/01 26 84 .34 0 PCT 17 P6 CTS .67 SAR CTS CTS .720 ZPS3C 64 C 31l l 2004/05/01 26 84 .39 0 PCT 20 P6 CTS .67 SAR CTS CTS .700 ZPS3C 34 C 68l l 2002/10/01 26 84 .43 0 PCT 20 P3 CTS .69 CTS CTS .700 ZPS3C 4 C 17l l 2001/04/01 26 84 .32 0 PCT 20 P3 CTS .69 CTS CTS .700 ZPS3C 58 C 7l l l l 2010/04/01 23 86 .36 143 PCT 18 P6 CTS .62 SR CTS CTS .720 ZRSNR 40 C 19l l 2010/04/01 23 86 .31 79 PCT 17 P6 CTS .66 SR CTS CTS .720 ZRSNR 40 C 19l l 2007/04/01 23 86 .37 0 PCT 19 P6 CTS .65 SAR CTS CTS .720 ZPS3C 64 C 30l l 2004/05/01 23 86 .34 0 PCT 18 P6 CTS .65 SAR CTS CTS .700 ZPS3C 34 C 69l l l l 1993/09/01 20 87 .69 169 PCT 9 1 05C 34.87 R93B04 CTE HTE .720 ZBAGB 14 H l l 1992/04/01 20 87 .64 165 PCT 15 1 05C 34.93 R92B02 CTE HTE .720 ZBAGB 7 H l l 1990/10/01 20 87 .90 164 PCT 11 1 05C 35.80 CTE HTE .720 ZBAGB 13 H l l l l 2017/03/01 8 89 .56 127 PCT 19 Q1 HTS .00 .36 .29 01H HTE .720 ZYAX2 37 H 8l l 2014/03/01 8 89 .96 88 PCT 23 P48 HTS .08 01H HTE .720 ZYAAP 28 H 84l l 2013/10/01 8 89 .99 110 PCT 24 Q2 HTS -.02 .19 0.45 0.21 01H HTE .720 ZYAXA 27 H 7l l l l 2010/04/01 16 89 .39 110 PCT 18 P6 CTS .60 SR CTS CTS .720 ZRSNR 36 C 97l l 2007/04/01 16 89 .47 0 PCT 21 P6 CTS .60 SAR CTS CTS .720 ZPS3C 62 C 40l l 2004/05/01 16 89 .46 0 PCT 21 P6 CTS .60 SAR CTS CTS .700 ZPS3C 34 C 71l l l l 2020/11/01 11 91 .57 148 PCT 15 162 CTS .74 17902.1 15 .40 .43 01C CTE .720 ZYAX2 6 C 410l l 2017/03/01 11 91 .77 159 PCT 20 P2 CTS .62 .41 .22 01C CTE .720 ZYAX2 6 C 178l l l l 2010/04/01 1 92 .08 20 PCT 13 P6 HTS 2.02 SR HTS FBH .720 ZRSNR 51 H 44l l 2010/04/01 1 92 .24 156 PCT 17 P6 HTS 2.88 SR HTS FBH .720 ZRSNR 51 H 44l l 2010/04/01 1 92 .15 28 PCT 15 P6 HTS 13.91 SR HTS FBH .720 ZRSNR 51 H 44l l 2010/04/01 1 92 .26 97 PCT 17 P6 CTS 10.41 SR CTS FBC .720 ZRSNR 64 C 26l l 2010/04/01 1 92 .30 141 PCT 18 P6 CTS 11.84 SR CTS FBC .720 ZRSNR 64 C 26l l 2007/04/01 1 92 .16 0 PCT 12 P6 HTS 2.02 SAR HTS FBH .720 ZPS3C 41 H 20l l 2007/04/01 1 92 .33 0 PCT 16 P6 HTS 2.88 SAR HTS FBH .720 ZPS3C 41 H 20l l 2007/04/01 1 92 .14 0 PCT 15 P6 HTS 13.91 SAR HTS FBH .720 ZPS3C 41 H 20l l 2004/05/01 1 92 .18 0 PCT 13 P6 HTS 2.03 SAR HTS FBH .700 ZPS3C 28 H 9l l 2004/05/01 1 92 .23 0 PCT 15 P6 HTS 2.84 SAR HTS FBH .700 ZPS3C 28 H 9l l 2004/05/01 1 92 .17 0 PCT 13 P6 HTS 13.56 SAR HTS FBH .700 ZPS3C 28 H 9l l 2004/05/01 1 92 .32 0 PCT 17 P6 CTS 8.55 SAR CTS FBC .700 ZPS3C 34 C 73l l 2004/05/01 1 92 .36 0 PCT 18 P6 CTS 9.62 SAR CTS FBC .700 ZPS3C 34 C 73l l 2004/05/01 1 92 .41 0 PCT 19 P6 CTS 10.92 SAR CTS FBC .700 ZPS3C 34 C 73l l 2004/05/01 1 92 .31 0 PCT 16 P6 CTS 11.86 SAR CTS FBC .700 ZPS3C 34 C 73l l 2002/10/01 1 92 .26 0 PCT 15 P3 CTS 8.55 CTS FBC .700 ZPS3C 4 C 19l l 2002/10/01 1 92 .28 0 PCT 16 P3 CTS 9.62 CTS FBC .700 ZPS3C 4 C 19l l 2002/10/01 1 92 .25 0 PCT 16 P3 CTS 10.92 CTS FBC .700 ZPS3C 4 C 19l l 2002/10/01 1 92 .08 0 PCT 24 P3 CTS 10.92 CTS FBC .700 ZPS3C 4 C 19l l 2002/10/01 1 92 .27 0 PCT 16 P3 CTS 11.86 CTS FBC .700 ZPS3C 4 C 19l l 2002/10/01 1 92 .48 0 PCT 13 P3 HTS 1.94 SAR HTS FBH .700 ZPS3C 16 H 5l l 2002/10/01 1 92 1.20 0 PCT 17 P3 HTS 2.82 SAR HTS FBH .700 ZPS3C 16 H 5l l 2002/10/01 1 92 .59 0 PCT 14 P3 HTS 14.12 SAR HTS FBH .700 ZPS3C 16 H 5l l 2001/04/01 1 92 .15 0 PCT 14 P3 HTS 1.94 HTS FBH .700 ZPS3C 39 H 4l l 2001/04/01 1 92 .34 0 PCT 19 P3 HTS 2.82 HTS FBH .700 ZPS3C 39 H 4l l 2001/04/01 1 92 .17 0 PCT 15 P3 HTS 14.12 HTS FBH .700 ZPS3C 39 H 4l l 2001/04/01 1 92 .23 0 PCT 12 P3 CTS 8.55 CTS FBC .700 ZPS3C 52 C 4l l 2001/04/01 1 92 .27 0 PCT 13 P3 CTS 9.62 CTS FBC .700 ZPS3C 52 C 4l l 2001/04/01 1 92 .22 0 PCT 12 P3 CTS 10.92 CTS FBC .700 ZPS3C 52 C 4l l 2001/04/01 1 92 .21 0 PCT 12 P3 CTS 11.86 CTS FBC .700 ZPS3C 52 C 4l l l l 2017/03/01 2 92 .21 120 PCT 13 Q1 FBH .28 WAR .18 .22 01H HTE .720 ZYAX2 38 H 31l l 2014/03/01 2 92 .23 0 PCT 14 P43 FBH .16 WAR .13 27 .21 01H HTE .720 ZYAAP 26 H 104l l 2010/04/01 2 92 .25 146 PCT 17 P6 CTS 11.20 SR CTS FBC .720 ZRSNR 34 C 80l l 2007/04/01 2 92 .21 0 PCT 14 P6 CTS 11.00 SAR CTS FBC .720 ZPS3C 62 C 45l l 2004/05/01 2 92 .32 0 PCT 17 P6 CTS 10.66 SAR CTS FBC .700 ZPS3C 34 C 72l l 2002/10/01 2 92 .24 0 PCT 15 P3 CTS 10.66 CTS FBC .700 ZPS3C 4 C 18l l 2001/04/01 2 92 .15 0 PCT 10 P3 CTS 10.66 CTS FBC .700 ZPS3C 52 C 5l l l l 2020/11/01 7 92 .36 122 PCT 12 22 CTS .72 17902.1 12 .36 .36 01C CTE .720 ZYAX2 6 C 411l l 2017/03/01 7 92 .46 143 PCT 16 P2 CTS .64 .28 .22 01C CTE .720 ZYAX2 6 C 174l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
Tubes: 107 Records: 390 5 ST Max
SG - C Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2010/04/01 7 1 .21 82 PCT 18 P6 CTS .58 SR CTS CTS .720 ZRSNR 48 C 63l l 2007/04/01 7 1 .18 0 PCT 15 P6 CTS .60 SAR CTS CTS .720 ZPS3C 52 C 13l l 2004/05/01 7 1 .21 0 PCT 15 P6 CTS .69 SAR CTS CTS .700 ZPS3C 32 C 28l l 2002/10/01 7 1 .12 0 PCT 15 P7 CTS .64 CTS CTS .700 ZPS3C 33 C 6l l 1995/05/01 7 1 .40 146 PCT 29 1 CTS 9.65 CTE HTE .720 ZBALC 1 H l l l l 1993/09/01 13 3 1.12 158 PCT 19 1 CTS 11.41 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 3 1.50 161 PCT 17 1 CTS 12.46 R93C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 3 1.13 163 PCT 17 1 CTS 11.28 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 3 1.51 164 PCT 16 1 CTS 12.31 R92C01 CTE HTE .720 ZBALC 1 H l l 1990/10/01 13 3 1.34 155 PCT 21 1 CTS 11.30 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 3 1.41 162 PCT 15 1 CTS 12.30 CTE HTE .720 ZBALC 4 H l l 1988/11/01 13 3 .87 167 PCT 18 1 CTS 11.30 CTE .720 ZBASF 2 l l 1988/11/01 13 3 1.11 168 PCT 17 1 CTS 12.30 CTE .720 ZBASF 2 l l 1987/05/01 13 3 .78 163 PCT 19 1 CTS 11.10 CTE HTE .720 ZBASF 1 H l l 1987/05/01 13 3 1.08 167 PCT 15 1 CTS 12.00 CTE HTE .720 ZBASF 1 H l l l l 1994/03/01 13 4 1.78 165 PCT 15 1 CTS 14.10 FBC CTE .720 ZBALC 4 C l l 1994/03/01 13 4 2.80 171 PCT 10 1 CTS 15.30 FBC CTE .720 ZBALC 4 C l l 1994/03/01 13 4 5.20 178 PCT 4 1 CTS 16.40 FBC CTE .720 ZBALC 4 C l l 1994/03/01 13 4 4.30 171 PCT 10 1 CTS 18.80 FBC CTE .720 ZBALC 4 C l l 1994/03/01 13 4 5.18 174 PCT 8 1 CTS 19.90 FBC CTE .720 ZBALC 4 C l l 1993/09/01 13 4 1.85 168 PCT 11 1 CTS 10.05 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 4 2.53 173 PCT 6 1 CTS 11.25 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 4 .72 154 PCT 23 1 CTS 14.53 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 4 .91 169 PCT 10 1 CTS 15.68 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 4 3.64 176 PCT 3 1 CTS 16.35 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 4 4.46 178 PCT 2 1 CTS 17.55 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 4 4.61 172 PCT 7 1 CTS 20.16 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 13 4 4.71 175 PCT 4 1 CTS 21.33 R93C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 1.84 169 PCT 13 1 CTS 10.01 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 2.56 173 PCT 9 1 CTS 11.10 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 .73 157 PCT 22 1 CTS 14.43 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 .93 161 PCT 19 1 CTS 15.51 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 3.61 176 PCT 7 1 CTS 16.18 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 4.50 178 PCT 5 1 CTS 17.26 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 4.64 173 PCT 9 1 CTS 19.98 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 13 4 4.76 175 PCT 8 1 CTS 21.08 R92C01 CTE HTE .720 ZBALC 1 H l l 1990/10/01 13 4 2.14 164 PCT 13 1 CTS 10.00 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 4 2.34 171 PCT 8 1 CTS 11.10 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 4 .90 158 PCT 18 1 CTS 14.19 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 4 .89 163 PCT 14 1 CTS 15.50 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 4 4.25 173 PCT 6 1 CTS 16.20 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 4 4.11 177 PCT 3 1 CTS 17.29 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 4 5.15 170 PCT 8 1 CTS 19.89 CTE HTE .720 ZBALC 4 H l l 1990/10/01 13 4 4.32 173 PCT 6 1 CTS 21.00 CTE HTE .720 ZBALC 4 H l l l l 1993/09/01 19 6 1.17 168 PCT 10 1 FBC 1.41 R93C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 19 6 1.10 170 PCT 12 1 FBC 1.41 R92C01 CTE HTE .720 ZBALC 1 H l l 1990/10/01 19 6 1.30 165 PCT 13 1 FBC 1.40 CTE HTE .720 ZBALC 4 H l l l l 2014/03/01 18 7 .60 0 PCT 20 P50 05C -.70 WAR 05C CTE .720 ZYAAP 43 C 9l l 2013/10/01 18 7 .50 99 PCT 18 Q5 05C -.71 -.52 0.37 0.19 05C 05C .720 ZYAXA 30 C 13l l 2010/04/01 18 7 .75 96 PCT 28 P6 05C -.63 SR 05C 05C .720 ZRSNR 52 C 22l l l l 1995/05/01 10 9 .66 169 PCT 10 1 CTS 15.94 CTE HTE .720 ZBALC 1 H l l 1995/05/01 10 9 .67 144 PCT 31 1 CTS 17.08 CTE HTE .720 ZBALC 1 H l l l l 2020/11/01 20 9 1.25 92 PCT 32 86 CTS 6.12 17902.3 24 .31 .29 01C CTE .720 ZYAX2 7 C 185l l 2020/11/01 20 9 1.17 82 PCT 31 134 CTS 6.48 17902.3 22 .31 .29 01C CTE .720 ZYAX2 7 C 185l l 2017/03/01 20 9 1.12 117 PCT 25 Q1 CTS 6.20 .25 .43 01C CTE .720 ZYAX2 3 C 189l l 2017/03/01 20 9 1.12 96 PCT 25 Q1 CTS 6.46 .25 .29 01C CTE .720 ZYAX2 3 C 189l l 1995/05/01 20 9 .94 150 PCT 26 1 CTS 6.52 CTE HTE .720 ZBALC 1 H l l 1995/05/01 20 9 .91 139 PCT 35 1 CTS 6.81 CTE HTE .720 ZBALC 1 H l l l l 1995/05/01 10 10 .81 153 PCT 23 1 CTS 16.07 CTE HTE .720 ZBALC 1 H l l 1993/09/01 10 10 .55 149 PCT 7 P 1 CTS 15.45 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 10 10 .59 143 PCT 14 P 1 CTS 16.62 R93C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 10 10 .55 167 PCT 14 1 CTS 15.22 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 10 10 .72 163 PCT 17 1 CTS 16.31 R92C01 CTE HTE .720 ZBALC 1 H l l l l 1993/09/01 10 11 1.24 169 PCT 8 1 CTS 3.38 R93C01 CTE HTE .720 ZBALC 1 H l l 1993/09/01 10 11 .83 165 PCT 11 1 CTS 4.47 R93C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 10 11 1.09 171 PCT 11 1 CTS 3.31 R92C01 CTE HTE .720 ZBALC 1 H l l 1992/04/01 10 11 1.04 172 PCT 10 1 CTS 4.40 R92C01 CTE HTE .720 ZBALC 1 H l l 1990/10/01 10 11 1.20 166 PCT 8 1 CTS 3.10 CTE HTE .720 ZBALC 5 H l l l l 1995/05/01 9 12 .43 150 PCT 26 1 CTS 8.68 CTE HTE .720 ZBALC 2 H l l l l 2017/03/01 30 13 1.17 58 PCT 25 Q1 FBH .54 .28 .36 01H HTE .720 ZYAX2 31 H 61l l 2013/10/01 30 13 .50 117 PCT 18 Q10 04H -.78 -.56 0.37 0.22 04H 04H .720 ZYAXA 26 H 21l l l l 2004/05/01 31 13 .13 0 PCT 4 P8 06C -.45 SAR 06C 06C .700 ZPS3C 36 C 11l l 2004/05/01 31 13 .16 0 PCT 5 P8 06C .60 SAR 06C 06C .700 ZPS3C 36 C 11l l 2002/10/01 31 13 .18 0 PCT 5 P6 06C -.44 06C 06C .700 ZPS3C 33 C 10l l 2002/10/01 31 13 .22 0 PCT 6 P6 06C .63 06C 06C .700 ZPS3C 33 C 10l l l l 2010/04/01 8 15 1.34 100 PCT 39 P6 04C -.58 SR 04C 04C .720 ZRSNR 52 C 9l l l l 2014/03/01 25 15 1.69 0 PCT 29 P42 03C -.48 WAR 03C CTE .720 ZYAAP 43 C 10l l 2013/10/01 25 15 1.40 75 PCT 27 Q16 03C -.77 -.58 0.45 0.19 03C 03C .720 ZYAXA 30 C 14l l 2010/04/01 25 15 .53 129 PCT 23 P6 03C -.65 SR 03C 03C .720 ZRSNR 52 C 21l l l l 2014/03/01 31 15 11.08 75 PCT 100 94 HTS .86 LPI SSV .25 59 .45 01H HTE .720 ZYAAP 16 H 25l l 2014/03/01 31 15 4.79 47 PCT 101 P1 HTS .77 .31 32 .25 HTS FBH .720 ZRSNR 36 H 15l l 2014/03/01 31 15 .55 0 PCT 19 P52 HTS .07 P1I .15 35 .27 FBH HTE .720 ZYAAP 46 H 11l l l l 1995/05/01 10 16 .86 162 PCT 16 1 CTS 8.22 CTE HTE .720 ZBALC 3 H l l l l 2020/11/01 31 16 .40 88 PCT 13 243 HTS .72 17902.1 14 .49 .29 01H HTE .720 ZYAX2 21 H 74l l 2017/03/01 31 16 .20 122 PCT 13 Q1 HTS .46 .20 .14 01H HTE .720 ZYAX2 31 H 79l l 2014/03/01 31 16 .32 0 PCT 14 P19 HTS .99 P2I LPR .23 35 .27 01H HTE .720 ZYAAP 56 H 9l l l l 2020/11/01 17 17 1.12 62 PCT 30 26 02H -.62 17902.3 25 .40 .43 02H 02H .720 ZYAX2 22 H 479l l 2017/03/01 17 17 1.07 113 PCT 25 Q1 02H -.74 .25 .22 02H 02H .720 ZYAX2 33 H 185l l 2014/03/01 17 17 1.05 0 PCT 24 P57 02H -.26 .16 42 .32 03H HTE .720 ZYAAP 44 H 20l l l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
1 ST Max
SG - C Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 1993/09/01 23 17 1.78 164 PCT 12 1 CTS 1.22 R93C01 CTE HTE .720 ZBALC 2 H l l l l 2020/11/01 16 19 1.09 101 PCT 30 134 03H -.71 17902.3 .44 .43 03H 03H .720 ZYAX2 22 H 480l l l l 2017/03/01 37 22 4.14 74 PCT 42 Q1 HTS 21.96 LPR .25 .29 01H HTE .720 ZYAX2 24 H 11l l l l 2020/11/01 6 23 .67 68 PCT 16 138 01H -.45 17902.1 17 .31 .29 01H HTE .720 ZYAX2 24 H 182l l 2017/03/01 6 23 .94 278 PCT 23 Q1 01H -.58 .15 .22 01H HTE .720 ZYAX2 35 H 33l l l l 2020/11/01 18 24 .73 99 PCT 24 14 02H -.60 17902.3 .49 .43 02H 02H .720 ZYAX2 22 H 481l l l l 2001/04/01 32 26 .92 0 PCT 32 P3 HTS .28 SAR UR2-DWL HTS HTS .680 ZPU3C 39 H 5l l l l 2017/03/01 6 27 2.70 81 PCT 35 Q1 02H -.63 .15 .29 02H 02H .720 ZYAX2 35 H 209l l 2013/10/01 6 27 2.10 95 PCT 32 Q15 02H -.62 -.42 0.45 0.20 02H 02H .720 ZYAXA 26 H 17l l 2010/04/01 6 27 .99 88 PCT 31 P6 02H -.57 SR 02H 02H .720 ZRSNR 51 H 44l l l l 2020/11/01 8 30 .87 84 PCT 26 239 03H -.91 17902.3 24 .31 .43 03H 03H .720 ZYAX2 23 H 344l l 2017/03/01 8 30 .99 92 PCT 24 Q1 03H -.80 .15 .22 03H 03H .720 ZYAX2 35 H 210l l l l 2020/11/01 2 31 .44 78 PCT 13 138 01C -.79 17902.1 16 .24 .29 01C CTE .720 ZYAX2 7 C 120l l 2017/03/01 2 31 .38 129 PCT 15 P2 01C -.91 .22 .25 01C CTE .720 ZYAX2 1 C 91l l 2014/03/01 2 31 .53 0 PCT 19 P50 01C .86 01C CTE .720 ZYAAP 37 C 15l l 2013/10/01 2 31 .64 132 PCT 20 Q9 01C -.96 0.45 0.29 01C CTE .720 ZYAXA 33 C 9l l l l 2017/03/01 4 31 25.76 21 SCI 239 HTE .03 01H HTE .720 ZYAX2 35 H 87l l 2013/10/01 4 31 38.92 26 SCI 157 HTE .00 01H HTE .720 ZYAXA 14 H 200l l l l 2020/11/01 17 32 .42 88 PCT 13 243 03H -.57 17902.1 .24 .14 03H 03H .720 ZYAX2 31 H 18l l l l 2020/11/01 25 34 .55 98 PCT 20 239 03C -.59 17902.3 .33 .36 03C 03C .720 ZYAX2 11 C 100l l l l 2004/05/01 39 34 .31 0 PCT 17 P6 02H -.82 SAR 02H 02H .700 ZPS3C 31 H 9l l l l 2004/05/01 39 35 .98 0 PCT 30 P6 02H -.74 SAR 02H 02H .700 ZPS3C 28 H 16l l l l 2020/11/01 44 36 1.13 81 PCT 30 239 06C -1.19 17902.3 .40 .43 06C 06C .720 ZYAX2 11 C 97l l l l 2010/04/01 44 38 .31 160 PCT 16 P6 HTS .55 SR HTS HTS .720 ZRSNR 51 H 40l l 2007/04/01 44 38 .33 0 PCT 17 P6 HTS .55 SAR HTS HTS .720 ZPS3C 41 H 46l l 2004/05/01 44 38 .15 0 PCT 17 P6 HTS .49 SAR HTS HTS .700 ZPS3C 13 H 17l l 2002/10/01 44 38 .28 0 PCT 16 P3 HTS .48 SAR HTS HTS .700 ZPS3C 15 H 26l l 2001/04/01 44 38 .30 0 PCT 18 P3 HTS .48 HTS HTS .700 ZPS3C 49 H 6l l 1994/03/01 44 38 .90 157 PCT 19 1 HTS .50 FBH HTE .720 ZBALC 5 H l l l l 1987/05/01 30 40 1.81 178 PCT 2 1 CTS 13.39 CTE HTE .720 ZBASF 2 H l l l l 2017/03/01 39 41 1.31 90 PCT 27 Q1 03H -.49 .23 .29 03H 03H .720 ZYAX2 33 H 174l l 2014/03/01 39 41 1.26 0 PCT 26 P39 03H -.52 03H HTE .720 ZYAAP 44 H 43l l 2013/10/01 39 41 .96 88 PCT 23 Q5 03H -.61 -.40 0.45 0.22 03H 03H .720 ZYAXA 26 H 20l l 2010/04/01 39 41 .87 78 PCT 31 P6 03H -.55 SR 03H 03H .720 ZRSNR 71 H 11l l l l 2002/10/01 45 41 2.55 0 PCT 50 P3 06H -.98 06H 06H .700 ZPS3C 25 H 6l l 1990/10/01 45 41 3.45 175 PCT 3 1 FBC 26.50 CTE HTE .720 ZBALC 2 H l l l l 2020/11/01 45 42 .41 153 PCT 17 P4 02A -.05 WAR CTE HTE .720 ZBAHS 5 H 247l l 2017/03/01 45 42 .58 150 PCT 21 P4 02A .00 WAR CTE HTE .720 ZBAHS 2 H 91l l 2014/03/01 45 42 .70 0 PCT 17 P2 02A .00 WAR HTE CTE .720 CBACC 47 C 19l l 2013/10/01 45 42 .75 128 PCT 15 P2 02A .02 HTE CTE .720 ZBAGB 19 C 24l l 2010/04/01 45 42 .90 140 PCT 18 P2 02A .00 4 SR HTE CTE .720 ZBAZC 60 C 7l l l l 2017/03/01 11 43 .91 277 PCT 23 Q1 03H -.63 .15 .22 03H 03H .720 ZYAX2 35 H 213l l 2014/03/01 11 43 .47 0 PCT 18 P43 03H -1.40 03H HTE .720 ZYAAP 50 H 8l l 2013/10/01 11 43 .66 108 PCT 20 Q6 03H -.64 0.52 0.28 03H 03H .720 ZYAXA 31 H 14l l l l 2020/11/01 45 44 1.37 93 PCT 27 Q1 06H -.41 11956.2 .23 .36 06H 06H .720 ZYAX2 22 H 465l l l l 2013/10/01 15 45 .28 122 PCT 14 Q16 02H -.75 0.52 0.26 02H 02H .720 ZYAXA 31 H 9l l 2010/04/01 15 45 .24 106 PCT 16 P6 02H -.80 SR 02H 02H .720 ZRSNR 71 H 10l l l l 2020/11/01 37 45 1.10 75 PCT 30 P4 03A .05 WAR CTE HTE .720 ZBAHS 7 H 24l l 2020/11/01 37 45 .96 69 PCT 28 P4 04A .07 WAR CTE HTE .720 ZBAHS 7 H 24l l 2017/03/01 37 45 1.16 70 PCT 31 P4 03A .21 WAR CTE HTE .720 ZBAHS 1 H 58l l 2017/03/01 37 45 1.01 71 PCT 29 P4 04A .05 WAR CTE HTE .720 ZBAHS 1 H 58l l 2014/03/01 37 45 1.72 0 PCT 27 P2 03A .00 WAR HTE CTE .720 CBACC 47 C 18l l 2014/03/01 37 45 1.60 0 PCT 27 P2 04A .00 WAR HTE CTE .720 CBACC 47 C 18l l 2013/10/01 37 45 1.88 69 PCT 28 P2 03A .00 HTE CTE .720 ZBAGB 19 C 23l l 2013/10/01 37 45 1.69 34 PCT 27 P2 04A .00 HTE CTE .720 ZBAGB 19 C 23l l 2010/04/01 37 45 1.98 95 PCT 29 P2 03A .00 9 SR HTE CTE .720 ZBAZC 60 C 8l l 2010/04/01 37 45 1.64 36 PCT 26 P2 04A .00 7 SR HTE CTE .720 ZBAZC 60 C 8l l 2007/04/01 37 45 .65 0 PCT 10 P2 03A .00 SAR HTE CTE .720 ZBAZC 60 C 11l l 2007/04/01 37 45 .62 0 PCT 10 P2 04A .00 SAR HTE CTE .720 ZBAZC 60 C 11l l 2004/05/01 37 45 .49 0 PCT 7 P2 03A -.18 SAR HTE CTE .720 ZBACS 33 C 9l l 2004/05/01 37 45 .43 0 PCT 6 P2 04A -.08 SAR HTE CTE .720 ZBACS 33 C 9l l 2002/10/01 37 45 .53 0 PCT 6 P2 03A .00 SAR HTE CTE .720 ZBALC 7 C 6l l 2002/10/01 37 45 .30 0 PCT 4 P2 04A .00 SAR HTE CTE .720 ZBALC 7 C 6l l 2002/10/01 37 45 .50 0 PCT 6 P2 03A .15 HTE CTE .720 ZBALC 17 C 11l l 2002/10/01 37 45 .35 0 PCT 4 P2 04A .02 HTE CTE .720 ZBALC 17 C 11l l 2001/04/01 37 45 .39 0 PCT 6 P2 03A .00 HTE CTE .720 ZBALC 56 C 8l l 2001/04/01 37 45 .19 0 PCT 3 P2 04A -.06 HTE CTE .720 ZBALC 56 C 8l l 1998/03/01 37 45 .14 PCT 3 P2 03A -.02 HTE CTE .720 ZBALC 7 C l l 1995/05/01 37 45 .58 0 PCT 3 P 2 03A -.11 HTE HTE .720 ZBALC 11 H l l l l 2020/11/01 9 46 .75 73 PCT 17 190 04A .00 17902.1 18 .31 .36 06C 06H .720 ZYAX2 24 H 373l l 2017/03/01 9 46 .69 37 PCT 19 P1 04A .00 .24 .24 04A 04A .700 ZYAX3 44 H 55l l l l 2010/04/01 32 46 2.34 97 PCT 51 P6 03H -.56 SR 03H 03H .720 ZRSNR 51 H 48l l l l 1995/05/01 45 46 .74 163 PCT 11 1 FBC 16.40 CTE HTE .720 ZBALC 10 H l l l l 2020/11/01 36 47 .74 256 PCT 21 Q11 03H -.61 11956.2 19 .24 .43 03H 03H .720 ZYAX2 27 H 213l l 2017/03/01 36 47 .70 95 PCT 21 Q1 03H -.57 WAR .20 .29 03H 03H .720 ZYAX2 29 H 16l l l l 1995/05/01 45 47 .82 137 PCT 18 P 1 06C -.48 HTE CTE .720 ZBALC 15 C l l l l 2017/03/01 10 49 .67 95 PCT 20 Q14 05C -.69 .28 .22 05C 05C .720 ZYAX2 6 C 160l l 2014/03/01 10 49 .72 83 PCT 21 P42 05C -1.00 05C CTE .720 ZYAAP 31 C 46l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
2 ST Max
SG - C Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2013/10/01 10 49 .72 86 PCT 21 Q16 05C -.98 -.79 0.37 0.19 05C 05C .720 ZYAXA 30 C 17l l l l 2020/11/01 14 49 .91 87 PCT 27 239 05H .42 17902.3 21 .36 .36 05H 05H .720 ZYAX2 27 H 208l l 2017/03/01 14 49 .72 50 PCT 21 Q1 05H .32 .11 .29 05H 05H .720 ZYAX2 35 H 215l l l l 2020/11/01 14 50 .64 85 PCT 22 206 01H -.86 17902.3 .16 .36 01H HTE .720 ZYAX2 27 H 119l l l l 2017/03/01 34 50 2.17 72 PCT 32 Q1 HTS -.29 .28 .36 01H HTE .720 ZYAX2 26 H 50l l 2014/03/01 34 50 1.86 0 PCT 31 P45 HTS .23 01H HTE .720 ZYAAP 56 H 412l l 2013/10/01 34 50 1.99 71 PCT 31 Q2 HTS .03 .26 0.45 0.23 01H HTE .720 ZYAXA 26 H 16l l 2010/04/01 34 50 .61 76 PCT 23 P6 HTS .04 SR HTS HTS .720 ZRSNR 51 H 49l l 2007/04/01 34 50 .66 0 PCT 23 P6 HTS .02 SAR HTS HTS .720 ZPS3C 41 H 52l l 2004/05/01 34 50 .56 0 PCT 24 P6 HTS .02 SAR HTS HTS .700 ZPS3C 13 H 14l l 2002/10/01 34 50 .54 0 PCT 14 P6 HTS -.03 HTS HTS .700 ZPS3C 23 H 13l l l l 2020/11/01 40 50 .15 150 PCT 7 P4 03A -.07 WAR CTE HTE .720 ZBAHS 12 H 56l l 2020/11/01 40 50 .18 35 PCT 9 P4 04A -.10 WAR CTE HTE .720 ZBAHS 12 H 56l l 2017/03/01 40 50 .23 158 PCT 11 P4 03A -.05 WAR CTE HTE .720 ZBAHS 12 H 64l l 2017/03/01 40 50 .25 106 PCT 11 P4 04A -.15 WAR CTE HTE .720 ZBAHS 12 H 64l l l l 2020/11/01 2 51 .59 86 PCT 15 46 05C -.46 17902.1 .16 .58 05C 05C .720 ZYAX2 11 C 168l l l l 2010/04/01 34 51 .45 71 PCT 19 P6 HTS .03 SR HTS HTS .720 ZRSNR 51 H 50l l 2007/04/01 34 51 .52 0 PCT 20 P6 HTS .05 SAR HTS HTS .720 ZPS3C 41 H 51l l 2004/05/01 34 51 .36 0 PCT 21 P6 HTS -.03 SAR HTS HTS .700 ZPS3C 13 H 15l l 2002/10/01 34 51 .25 0 PCT 7 P6 HTS .05 HTS HTS .700 ZPS3C 23 H 14l l l l 2010/04/01 35 51 .37 114 PCT 17 P6 HTS .06 SR HTS HTS .720 ZRSNR 51 H 51l l 2007/04/01 35 51 .38 0 PCT 18 P6 HTS .08 SAR HTS HTS .720 ZPS3C 41 H 50l l 2004/05/01 35 51 .35 0 PCT 19 P6 HTS .03 SRADABA HTS HTS .700 ZPS3C 20 H 10l l l l 2020/11/01 40 52 .25 144 PCT 12 P4 04A .09 WAR CTE HTE .720 ZBAHS 11 H 86l l 2017/03/01 40 52 .26 150 PCT 12 P4 04A .14 WAR CTE HTE .720 ZBAHS 12 H 94l l 2014/03/01 40 52 .34 0 PCT 11 P2 04A .00 WAR HTE CTE .720 CBACC 47 C 17l l 2013/10/01 40 52 .38 143 PCT 9 P2 04A .00 HTE CTE .720 ZBAGB 19 C 25l l 2010/04/01 40 52 .35 163 PCT 9 P2 04A .00 SR HTE CTE .720 ZBAZC 72 C 6l l l l 1995/05/01 22 53 .43 156 PCT 21 1 05C 7.42 HTE CTE .720 ZBALC 13 C l l l l 1993/09/01 10 54 .90 169 PCT 7 1 CTS 2.54 R93C03 CTE HTE .720 ZBALC 9 H l l 1992/04/01 10 54 .64 145 PCT 9 P 1 CTS 1.33 R92C02 CTE HTE .720 ZBALC 7 H l l 1992/04/01 10 54 .91 173 PCT 10 1 CTS 2.33 R92C02 CTE HTE .720 ZBALC 7 H l l 1990/10/01 10 54 .60 163 PCT 15 1 CTS 1.20 CTE HTE .720 ZBALC 1 H l l 1990/10/01 10 54 .82 171 PCT 8 1 CTS 2.40 CTE HTE .720 ZBALC 1 H l l l l 2020/11/01 13 54 .73 101 PCT 24 86 03H -.81 17902.3 22 .27 .43 03H 03H .720 ZYAX2 27 H 207l l l l 1993/09/01 10 55 .56 153 PCT 22 1 03C 11.01 R93C03 CTE HTE .720 ZBALC 9 H l l 1993/09/01 10 55 1.24 168 PCT 8 1 CTS 5.75 R93C03 CTE HTE .720 ZBALC 9 H l l 1993/09/01 10 55 2.53 175 PCT 1 1 CTS 6.96 R93C03 CTE HTE .720 ZBALC 9 H l l 1992/04/01 10 55 1.26 160 PCT 20 1 03C 10.97 R92C02 CTE HTE .720 ZBALC 7 H l l 1992/04/01 10 55 2.07 174 PCT 10 1 CTS 5.61 R92C02 CTE HTE .720 ZBALC 7 H l l 1992/04/01 10 55 2.03 179 PCT 6 1 CTS 6.65 R92C02 CTE HTE .720 ZBALC 7 H l l 1990/10/01 10 55 .96 162 PCT 16 1 03C 11.00 CTE HTE .720 ZBALC 1 H l l 1990/10/01 10 55 1.69 175 PCT 5 1 CTS 6.00 CTE HTE .720 ZBALC 1 H l l 1990/10/01 10 55 2.18 178 PCT 2 1 CTS 7.10 CTE HTE .720 ZBALC 1 H l l l l 2001/04/01 44 56 1.76 0 PCT 43 P3 FBH .45 SAR HTS FBH .680 ZPU3C 53 H 8l l l l 1993/09/01 11 57 2.26 167 PCT 9 1 CTS 7.04 R93C03 CTE HTE .720 ZBALC 9 H l l l l 2010/04/01 44 57 .30 115 PCT 20 P6 CTS .70 SR CTS CTS .720 ZRSNR 48 C 27l l 2010/04/01 44 57 .30 145 PCT 16 P6 HTS .51 SR HTS FBH .720 ZRSNR 51 H 53l l 2010/04/01 44 57 .28 109 PCT 15 P6 HTS 1.19 SR HTS FBH .720 ZRSNR 51 H 53l l 2007/04/01 44 57 .33 0 PCT 17 P6 HTS .56 SAR HTS HTS .720 ZPS3C 41 H 48l l 2007/04/01 44 57 .30 0 PCT 16 P6 HTS 1.21 SAR HTS HTS .720 ZPS3C 41 H 48l l 2007/04/01 44 57 .32 0 PCT 18 P6 CTS .65 SAR CTS CTS .720 ZPS3C 52 C 32l l 2004/05/01 44 57 .28 0 PCT 16 P6 HTS .61 SAR HTS HTS .700 ZPS3C 13 H 16l l 2004/05/01 44 57 .26 0 PCT 15 P6 HTS 1.18 SAR HTS HTS .700 ZPS3C 13 H 16l l 2004/05/01 44 57 .33 0 PCT 19 P6 CTS .67 SAR CTS CTS .700 ZPS3C 34 C 15l l 2002/10/01 44 57 .27 0 PCT 16 P3 HTS .58 SAR HTS HTS .700 ZPS3C 15 H 23l l 2002/10/01 44 57 .23 0 PCT 15 P3 HTS 1.18 SAR HTS HTS .700 ZPS3C 15 H 23l l 2001/04/01 44 57 .26 0 PCT 17 P3 HTS .58 HTS HTS .680 ZPU3C 39 H 6l l 2001/04/01 44 57 .25 0 PCT 17 P3 HTS 1.18 HTS HTS .680 ZPU3C 39 H 6l l 1994/03/01 44 57 .60 165 PCT 12 1 HTS .50 FBH HTE .720 ZBALC 5 H l l 1994/03/01 44 57 .40 161 PCT 15 1 HTS 1.10 FBH HTE .720 ZBALC 5 H l l l l 1993/09/01 10 58 .81 164 PCT 12 1 CTS 2.26 R93C03 CTE HTE .720 ZBALC 9 H l l 1993/09/01 10 58 1.34 169 PCT 7 1 CTS 3.49 R93C03 CTE HTE .720 ZBALC 9 H l l l l 1993/09/01 9 60 1.12 169 PCT 8 1 CTS 9.20 R93C03 CTE HTE .720 ZBALC 9 H l l l l 2017/03/01 28 61 1.19 110 PCT 23 P1 01A -1.19 .25 .14 01A 06H .720 ZYAX2 30 H 26l l 2014/03/01 28 61 1.15 95 PCT 23 P38 01A -1.33 06H CTE .720 ZYAAP 31 C 47l l 2013/10/01 28 61 .86 100 PCT 20 P25 01A -1.33 -1.02 0.22 0.31 06H 06C .720 ZYAXA 26 C 18l l 2010/04/01 28 61 .61 107 PCT 24 P6 01A -1.08 SR 06H 02A .680 ZRUN8 75 H 10l l l l 2020/11/01 35 61 .15 209 PCT 8 P4 01A -.28 WAR CTE HTE .720 ZBAHS 11 H 208l l 2020/11/01 35 61 .52 111 PCT 19 P4 02A -.21 WAR CTE HTE .720 ZBAHS 11 H 208l l 2020/11/01 35 61 .68 119 PCT 23 P4 02A .18 WAR CTE HTE .720 ZBAHS 11 H 208l l 2020/11/01 35 61 1.41 103 PCT 34 P4 03A -.22 WAR CTE HTE .720 ZBAHS 11 H 208l l 2020/11/01 35 61 .17 44 PCT 8 P4 04A -.15 WAR CTE HTE .720 ZBAHS 11 H 208l l 2017/03/01 35 61 .20 214 PCT 9 P4 01A -.28 WAR CTE HTE .720 ZBAHS 14 H 30l l 2017/03/01 35 61 .72 141 PCT 24 P4 02A .00 WAR CTE HTE .720 ZBAHS 14 H 30l l 2017/03/01 35 61 1.19 90 PCT 31 P4 03A .22 WAR CTE HTE .720 ZBAHS 14 H 30l l 2017/03/01 35 61 .18 75 PCT 9 P4 04A -.24 WAR CTE HTE .720 ZBAHS 14 H 30l l 2014/03/01 35 61 .41 0 PCT 12 P2 01A .00 WAR HTE CTE .720 CBACC 47 C 14l l 2014/03/01 35 61 1.07 0 PCT 22 P2 02A .00 WAR HTE CTE .720 CBACC 47 C 14l l 2014/03/01 35 61 1.38 0 PCT 25 P2 03A .00 WAR HTE CTE .720 CBACC 47 C 14l l 2014/03/01 35 61 .19 0 PCT 7 P2 04A -.31 WAR HTE CTE .720 CBACC 47 C 14l l 2013/10/01 35 61 .27 167 PCT 6 P2 01A -.15 HTE CTE .720 ZBAGB 19 C 26l l 2013/10/01 35 61 1.32 142 PCT 23 P2 02A .00 HTE CTE .720 ZBAGB 19 C 26l l 2013/10/01 35 61 1.42 53 PCT 24 P2 03A .23 HTE CTE .720 ZBAGB 19 C 26l l 2013/10/01 35 61 .12 13 PCT 2 P2 04A -.02 HTE CTE .720 ZBAGB 19 C 26l l 2010/04/01 35 61 .52 149 PCT 12 P2 01A .00 3 SR HTE CTE .720 ZBAZC 60 C 10l l 2010/04/01 35 61 1.31 139 PCT 23 P2 02A .00 6 SR HTE CTE .720 ZBAZC 60 C 10l l 2010/04/01 35 61 1.50 78 PCT 25 P2 03A .00 7 SR HTE CTE .720 ZBAZC 60 C 10l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
3 ST Max
SG - C Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l 2010/04/01 35 61 .17 18 PCT 5 P2 04A .00 1 SR HTE CTE .720 ZBAZC 60 C 10l l 2007/04/01 35 61 .30 124 PCT 7 P2 02A -.38 SAR HTE CTE .720 ZBAZC 54 C 16l l 2007/04/01 35 61 .24 131 PCT 5 P2 03A -.13 SAR HTE CTE .720 ZBAZC 54 C 16l l 2007/04/01 35 61 .25 127 PCT 5 P2 04A .11 SAR HTE CTE .720 ZBAZC 54 C 16l l 2004/05/01 35 61 .43 0 PCT 6 P2 02A -.13 SAR HTE CTE .720 ZBACS 33 C 12l l 2004/05/01 35 61 .35 0 PCT 5 P2 03A .18 SAR HTE CTE .720 ZBACS 33 C 12l l 2002/10/01 35 61 .42 0 PCT 5 P2 02A -.21 SAR HTE CTE .720 ZBALC 7 C 7l l 2002/10/01 35 61 .28 0 PCT 3 P2 03A .13 SAR HTE CTE .720 ZBALC 7 C 7l l 2001/04/01 35 61 .31 PCT 5 P2 02A .41 HTE CTE .720 ZBALC 54 C 9l l 2001/04/01 35 61 .31 PCT 5 P2 03A .48 HTE CTE .720 ZBALC 54 C 9l l 1998/03/01 35 61 .23 PCT 5 P2 02A .44 HTE CTE .720 ZBALC 10 C l l 1995/05/01 35 61 .68 0 PCT 4 P 2 02A .00 HTE CTE .720 ZBALC 11 C l l l l 1993/09/01 10 62 1.05 158 PCT 17 1 CTS 7.62 R93C03 CTE HTE .720 ZBALC 10 H l l 1993/09/01 10 62 1.66 169 PCT 7 1 CTS 8.65 R93C03 CTE HTE .720 ZBALC 10 H l l l l 2010/04/01 38 62 .86 152 PCT 18 P2 02A .00 4 SR HTE CTE .720 ZBAZC 60 C 11l l 2010/04/01 38 62 3.94 92 PCT 39 P2 03A .00 15 SR HTE CTE .720 ZBAZC 60 C 11l l 2010/04/01 38 62 .57 157 PCT 13 P2 04A .00 3 SR HTE CTE .720 ZBAZC 60 C 11l l 2007/04/01 38 62 .29 38 PCT 6 P2 02A -.29 SAR HTE CTE .720 ZBAZC 54 C 15l l 2007/04/01 38 62 .82 138 PCT 15 P2 03A -.32 SAR HTE CTE .720 ZBAZC 54 C 15l l 2004/05/01 38 62 .23 0 PCT 4 P2 02A -.53 SAR HTE CTE .720 ZBACS 33 C 13l l 2004/05/01 38 62 1.08 0 PCT 14 P2 03A -.26 SAR HTE CTE .720 ZBACS 33 C 13l l 2002/10/01 38 62 .25 0 PCT 3 P2 02A -.23 SAR HTE CTE .720 ZBALC 7 C 8l l 2002/10/01 38 62 1.05 0 PCT 11 P2 03A -.31 SAR HTE CTE .720 ZBALC 7 C 8l l 2001/04/01 38 62 .25 PCT 4 P2 02A -.05 HTE CTE .720 ZBALC 54 C 10l l 2001/04/01 38 62 .94 PCT 13 P2 03A -.13 HTE CTE .720 ZBALC 54 C 10l l 1998/03/01 38 62 1.94 PCT 9 P2 03A -.65 HTE CTE .720 ZBALC 29 C l l 1995/05/01 38 62 .79 0 PCT 5 P 2 03A .60 HTE CTE .720 ZBALC 11 C l l l l 2017/03/01 36 63 .65 95 PCT 20 Q1 04H -.68 WAR .20 .22 04H 04H .720 ZYAX2 29 H 25l l 2014/03/01 36 63 .45 0 PCT 17 P45 04H -.80 04H HTE .720 ZYAAP 44 H 52l l 2013/10/01 36 63 .57 76 PCT 19 Q8 04H -.72 -.48 0.37 0.24 04H 04H .720 ZYAXA 26 H 23l l l l 1995/05/01 35 65 1.39 152 PCT 29 1 05H 37.80 HTE CTE .720 ZBALC 8 C l l 1993/09/01 35 65 1.08 144 PCT 30 1 05H 37.94 R93C03 CTE HTE .720 ZBALC 10 H l l l l 1995/05/01 40 68 .71 0 PCT 4 P 2 06C .70 HTE CTE .720 ZBALC 11 C l l l l 2014/03/01 30 69 .38 0 PCT 16 P50 02H -.69 02H HTE .720 ZYAAP 44 H 68l l 2013/10/01 30 69 .35 87 PCT 16 Q11 02H -.78 -.66 0.30 0.13 02H 02H .720 ZYAXA 26 H 24l l 2010/04/01 30 69 .42 102 PCT 20 P6 02H -.71 SR 02H 02H .720 ZRSNR 71 H 13l l l l 2010/04/01 23 70 1.01 90 PCT 33 P6 05C -.86 SR 05C 05C .720 ZRSNR 52 C 26l l l l 2010/04/01 27 71 1.44 78 PCT 41 P6 04C -.57 SR 04C 04C .720 ZRSNR 52 C 28l l l l 2020/11/01 30 71 .80 282 PCT 22 Q6 03H -.66 11956.2 20 .29 .43 03H 03H .720 ZYAX2 27 H 223l l 2017/03/01 30 71 .66 78 PCT 20 Q1 03H -.62 WAR .20 .36 03H 03H .720 ZYAX2 29 H 26l l 2014/03/01 30 71 .61 0 PCT 20 P42 03H -.90 WAR 03H HTE .720 ZYAAP 44 H 69l l 2013/10/01 30 71 .63 68 PCT 20 Q6 03H -.56 -.44 0.45 0.12 03H 03H .720 ZYAXA 26 H 25l l l l 1987/05/01 38 71 2.94 175 PCT 4 1 FBC 9.89 CTE HTE .720 ZBASF 6 H l l l l 2020/11/01 30 72 .59 68 PCT 21 239 03H -.64 17902.3 22 .31 .14 CTE HTE .720 ZYAX2 25 H 302l l 2017/03/01 30 72 .56 71 PCT 19 Q1 03H -.62 WAR .20 .29 03H 03H .720 ZYAX2 37 H 165l l 2014/03/01 30 72 .80 0 PCT 22 P53 03H -.55 WAR 03H HTE .720 ZYAAP 44 H 70l l 2013/10/01 30 72 .86 86 PCT 22 Q15 03H -.58 -.42 0.37 0.16 03H 03H .720 ZYAXA 26 H 26l l l l 2020/11/01 35 73 .28 92 PCT 12 P4 04A -.08 WAR CTE HTE .720 ZBAHS 11 H 358l l 2017/03/01 35 73 .29 102 PCT 13 P4 04A -.17 WAR CTE HTE .720 ZBAHS 13 H 180l l 2014/03/01 35 73 .66 0 PCT 16 P2 04A .00 WAR HTE CTE .720 CBACC 47 C 15l l 2013/10/01 35 73 .61 87 PCT 13 P2 04A .00 HTE CTE .720 ZBAGB 19 C 37l l 2010/04/01 35 73 .78 93 PCT 16 P2 04A .00 3 SR HTE CTE .720 ZBAZC 60 C 12l l l l 2017/03/01 33 75 .50 100 PCT 18 Q20 03H -.66 .23 .29 03H 03H .720 ZYAX2 30 H 9l l 2014/03/01 33 75 .58 0 PCT 19 P44 03H -.90 03H HTE .720 ZYAAP 44 H 71l l 2013/10/01 33 75 .56 73 PCT 19 Q6 03H -.76 -.58 0.37 0.18 03H 03H .720 ZYAXA 26 H 27l l 2010/04/01 33 75 .61 98 PCT 23 P6 03H -.77 SR 03H 03H .720 ZRSNR 51 H 60l l 2007/04/01 33 75 .46 0 PCT 21 P6 03H -.89 SAR 03H 03H .720 ZPS3C 53 H 34l l l l 2010/04/01 35 75 .24 88 PCT 19 P6 CTS 1.49 SR CTS FBC .720 ZRSNR 48 C 22l l 2007/04/01 35 75 .26 0 PCT 17 P6 CTS 1.49 SAR CTS CTS .720 ZPS3C 52 C 33l l 2004/05/01 35 75 .26 0 PCT 17 P6 CTS 1.49 SAR CTS CTS .700 ZPS3C 32 C 12l l l l 2020/11/01 6 76 .55 75 PCT 20 239 01C 51.21 17902.3 .27 .29 02C 01C .720 ZYAX2 9 C 211l l l l 2014/03/01 8 76 .93 0 PCT 23 P40 04H -.69 WAR 04H HTE .720 ZYAAP 44 H 75l l 2013/10/01 8 76 1.12 96 PCT 25 Q17 04H -.85 -.66 0.37 0.20 04H 04H .720 ZYAXA 26 H 33l l 2010/04/01 8 76 .63 120 PCT 26 P6 04H -.82 SR 04H 04H .720 ZRSNR 71 H 15l l l l 2020/11/01 26 77 .81 63 PCT 25 2 02H -.53 17902.3 22 .31 .43 02H 02H .720 ZYAX2 27 H 225l l 2017/03/01 26 77 .77 77 PCT 22 Q2 02H -.46 .25 .22 02H 02H .720 ZYAX2 30 H 8l l 2014/03/01 26 77 .94 0 PCT 23 P41 02H -.55 .18 40 .31 02H HTE .720 ZYAAP 44 H 72l l l l 2020/11/01 32 78 .11 159 PCT 6 P4 03A -.09 WAR CTE HTE .720 ZBAHS 14 H 24l l 2017/03/01 32 78 .20 162 PCT 9 P4 03A -.26 WAR CTE HTE .720 ZBAHS 16 H 30l l 2014/03/01 32 78 .32 0 PCT 10 P2 03A .00 WAR HTE CTE .720 CBACC 47 C 16l l 2013/10/01 32 78 .44 133 PCT 10 P2 03A .00 HTE CTE .720 ZBAGB 19 C 39l l 2010/04/01 32 78 .51 153 PCT 12 P2 03A .00 2 SR HTE CTE .720 ZBAZC 60 C 13l l l l 2010/04/01 33 78 .20 110 PCT 13 P6 HTS .72 SR HTS HTS .720 ZRSNR 51 H 61l l 2007/04/01 33 78 .23 0 PCT 14 P6 HTS .66 SAR HTS HTS .720 ZPS3C 43 H 10l l 2004/05/01 33 78 .23 0 PCT 18 P6 HTS .63 SAR HTS HTS .700 ZPS3C 13 H 13l l 2002/10/01 33 78 .24 0 PCT 18 P7 HTS .66 HTS HTS .700 ZPS3C 23 H 20l l 2001/04/01 33 78 .18 0 PCT 15 P3 HTS .71 HTS HTS .700 ZPS3C 49 H 5l l l l 1993/09/01 25 81 3.80 174 PCT 2 1 05C 40.05 R93C04 CTE HTE .720 ZBALC 13 H l l l l 2017/03/01 19 82 .62 104 PCT 20 Q15 02H -.49 WAR .18 .14 02H 02H .720 ZYAX2 37 H 166l l 2014/03/01 19 82 .55 0 PCT 19 P45 02H -.55 02H HTE .720 ZYAAP 44 H 73l l 2013/10/01 19 82 .92 94 PCT 23 Q1 02H -.50 -.32 0.30 0.18 02H 02H .720 ZYAXA 26 H 30l l l l 2017/03/01 8 85 .26 101 PCT 14 Q1 03H -.55 WAR .23 .29 03H 03H .720 ZYAX2 31 H 8l l 2014/03/01 8 85 .65 0 PCT 20 P56 03H -.69 03H HTE .720 ZYAAP 44 H 76l l 2013/10/01 8 85 .52 73 PCT 18 Q14 03H -.54 -.42 0.37 0.12 03H 03H .720 ZYAXA 26 H 31l l 2010/04/01 8 85 .31 119 PCT 18 P6 03H -.73 SR 03H 03H .720 ZRSNR 71 H 16l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
4 ST Max
SG - C Seervice Induced Degradation H.B. Robinson 2 RFO32 RNP 20201101 04/26/2021 10:53:59
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l l l 1994/03/01 1 90 2.15 137 PCT 33 1 HTS .50 FBH HTE .720 ZBALC 2 H l l 1994/03/01 1 90 17.17 94 PCT 57 M 1 CTS .60 FBC CTE .720 ZBALC 3 C l l l l 1990/10/01 2 90 2.68 122 PCT 43 1 CTS .67 CTS CTS .720 ZRAGR 1 C l l 1990/10/01 2 90 7.15 126 PCT 44 1 CTS .60 CTE .680 ZBASF 16 H l l l l 1994/03/01 3 90 1.30 150 PCT 26 1 CTS .60 FBC CTE .720 ZBALC 3 C l l l l 2007/04/01 2 91 4.85 0 PCT 38 P6 CTS .05 SAR CTS CTS .720 ZPS3C 58 C 25l l l l 2017/03/01 3 91 .75 291 PCT 21 Q1 HTS .23 .20 .14 01H HTE .720 ZYAX2 30 H 253l l 2014/03/01 3 91 .64 80 PCT 18 P29 HTS .68 01H HTE .720 ZYAAP 28 H 209l l 2013/10/01 3 91 .69 65 PCT 21 Q6 HTS .20 .48 0.30 0.28 01H HTE .720 ZYAXA 26 H 32l l 2010/04/01 3 91 .69 87 PCT 25 P6 HTS .34 SR HTS HTS .720 ZRSNR 51 H 78l l 2007/04/01 3 91 .78 0 PCT 25 P6 HTS .39 SAR HTS HTS .720 ZPS3C 41 H 58l l 2004/05/01 3 91 .56 0 PCT 24 P6 HTS .39 SAR HTS HTS .700 ZPS3C 13 H 25l l 2002/10/01 3 91 .60 0 PCT 23 P3 HTS .32 SAR HTS HTS .700 ZPS3C 15 H 21l l 2001/04/01 3 91 .80 0 PCT 28 P3 HTS .28 HTS HTS .700 ZPS3C 49 H 4l l l l 1988/11/01 7 92 6.26 91 PCT 76 1 HTS 5.40 CTE .720 ZBASF 10 l
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
l INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 UTIL1 UTIL2 CRLEN CEG CRWID BEGT ENDT PDIA PTYPE CAL L IDXl
+-----------+----+----+---------+----+----+----+-----+----+---------+---------+---------+---------+-------+----+-------+----+----+------+------+------+--+-----+
Tubes: 95 Records: 355 5 ST Max