ML21125A583
Text
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-76 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 27 - 29 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-77 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements : 27 - 42 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-78 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 54 - 42 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-79 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 54 - 41 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-80 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 55 -41 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-81 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 56 - 41 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-82 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 56 - 40 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-83 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 57 - 40 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-84 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 57 - 25 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-85 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 27 - 28 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-86 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 54 - 28 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-87 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 55 - 28 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-88 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 55 - 26 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-89 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 56 - 26 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-90 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 57 - 26 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-91 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 27 - 3 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-92 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 54 - 2 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-93 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 54 - 3 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-94 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 55 - 2 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-95 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 56 - 2 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-96 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 56 - 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-97 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Between Elements: 57 - 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-98 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Fan / Accumulator Room Element 27 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-99 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Fan / Accumulator Room Element 54 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-100 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Fan / Accumulator Room Element 55 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-101 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Fan / Accumulator Room Element 56 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-102 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Fan / Accumulator Room Element 57 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-103 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 1 for a DEHL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-104 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 2 for a DEHL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-105 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 3 for a DEHL Break in Element 1 UFSAR Revision 30.0
Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-106 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 4 for a DEHL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-107 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 5 for a DEHL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-108 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 6 for a DEHL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-109 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 25 for a DEHL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-110 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 40 for a DEHL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-111 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time Element 2 for DEHL Break in Element 2 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-112 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 25 for a DEHL Break in Element 2 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-113 Sheet 1 of 1
Title:
Plot of the Peak Compartment Pressure as a Function of Time in Element 40 for a DECL Break in Element 1 UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-114 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Lower Compartment (When using this figure, the differential pressure time history should be increased by an adder of 1.936.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-115 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Upper Compartment (When using this figure, the differential pressure time history should be increased by an adder of 1.936.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-116 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Lower Compartment (When using this figure, the differential pressure time history should be first increased by a factor 1.087 psi and then an adder of 0.75 psi included.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-117 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Upper Compartment (When using this figure, the differential pressure time history should be first increased by a factor 1.087 psi and then an adder of 0.75 psi included.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-118 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Ice Condenser Compartment (When using this figure, the differential pressure time history should be first increased by a factor 1.013 psi and then an adder of 0.9426 psi included.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-119 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Upper Compartment (When using this figure, the differential pressure time history should be first increased by a factor 1.013 psi and then an adder of 0.9426 psi included.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-120 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Lower Plenum of the Ice Condenser (When using this figure for the differential pressure time history, it should be first increased by a factor 1.06 psi and then an adder of 0.866 psi included.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-121 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Lower Plenum of the Ice Condenser (When using this figure, the differential pressure time history should be increased by a factor 1.15 psi.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-122 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History in the Fan / Accumulator Room (When using this figure, the differential pressure time history should be increased by a factor 1.15 psi.)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-123 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-124 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-125 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-126 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-127 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-128 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-129 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-130 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-131 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Time History Reactor Cavity Subcompartment UFSAR Revision 30.0
Revision: 22.1 Change
Description:
UCR-1923 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-132 Sheet 1 of 1
Title:
Cook Unit 1 & 2 Differential Pressure Time History Reactor Cavity Subcompartment This figure is not updated because it is considered as a representative for the TMD analysis.
UCR-1923 provides details for minor increase (1.6928%) in operating deck accident pressure.
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-133 Sheet 1 of 1
Title:
Hot Leg Double Ended Guillotine Full Power mh Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-134 Sheet 1 of 1
Title:
Hot Leg Double Ended Guillotine Full Power m Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-135 Sheet 1 of 1
Title:
Cold Leg Double Ended Guillotine Full Power Condition mh Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-136 Sheet 1 of 1
Title:
Cold Leg Double Ended Guillotine Full Power Condition m Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-137 Sheet 1 of 1
Title:
Hot Leg Single Ended Split Full Power Condition mh Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-138 Sheet 1 of 1
Title:
Hot Leg Single Ended Split Full Power Condition m Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-139 Sheet 1 of 1
Title:
Cold Leg Single Ended Split Full Power mh Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-140 Sheet 1 of 1
Title:
Cold Leg Single Ended Split Full Power m Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-141 Sheet 1 of 1
Title:
Pressurizer Spray Line mh Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-142 Sheet 1 of 1
Title:
Pressurizer Spray Line m Transient UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-143 Sheet 1 of 1
Title:
Comparison of Satan (Zaloudek-Moody) to Henry-Fauske UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-144 Sheet 1 of 1
Title:
Comparison of Satan (Zaloudek) to Moody Subcooled UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-145 Sheet 1 of 1
Title:
Zaloudek Measured Data versus Modified Zaloudek Corp.
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-146 Sheet 1 of 1
Title:
Zaloudek Short Tube Data UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-147 Sheet 1 of 1
Title:
Exit Plane Quality as a Function of Upstream Pressure for Saturated Liquid (Moody Model)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-148 Sheet 1 of 1
Title:
Henry ANL 7740 Data UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-149 Sheet 1 of 1
Title:
Loft Tests 809 and 813 Pressure Gage P-1 (Near Rupture)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-150 Sheet 1 of 1
Title:
Full-Scale Section Test Facility UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-151 Sheet 1 of 1
Title:
Discharge Piping Circulation Pump UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-152 Sheet 1 of 1
Title:
Receiver Vessel UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-153 Sheet 1 of 1
Title:
Instrument Location UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-154 Sheet 1 of 1
Title:
Variable Area Flow Path UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-155 Sheet 1 of 1
Title:
Illustration of Choked Flow Characteristics UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-156 Sheet 1 of 1
Title:
Experimental Critical Mass Flow / Homogeneous Thermal Equilibrium Mode A summary of experimental, two-phase, choking flow studies UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-157 Sheet 1 of 1
Title:
Upper and Lower Compartment Pressure Transient for Worst Case Break Compartment (Element 6) Having a DEHL Break (Historical)
UFSAR Revision 30.0
Unit 1 Revision: 17.1 Change
Description:
UCR-850 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.4-158 Sheet 1 of 1
Title:
Flow Area - Pressure Differential
- Full flow area is defined as door port area at maximum door opening UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Mass of Ice Remaining in the Ice Condenser: DECL Break into the Lower Compartment FSAR FIG. 14.3.9-1 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 Time, Hours UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Reactor Cavity Water Level: DECL Break into the Lower Compartment FSAR FIG. 14.3.9-2 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Containment Water Level: DECL Break into the Lower Compartment FSAR FIG. 14.3.9-3 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 Time, Hours UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 RCS Pressure: DECL Break into the Lower Compartment FSAR FIG. 14.3.9-4 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Mass of Ice Remaining in the Ice Condenser: 1 Inch Break into the Reactor Cavity FSAR FIG. 14.3.9-5 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 Time, Hours UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Reactor Cavity Water Level: 1 Inch Break into the Reactor Cavity FSAR FIG. 14.3.9-6 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Containment Water Level: 1 Inch Break into the Reactor Cavity FSAR FIG. 14.3.9-7 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 Time, Hours UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 RCS Pressure: 1 Inch Break into the Reactor Cavity FSAR FIG. 14.3.9-8 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Mass of Ice Remaining in the Ice Condenser: 6 Inch Break into the Reactor Cavity in Mode 3 FSAR FIG. 14.3.9-9 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 Time, Hours UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Reactor Cavity Water Level: 6 Inch Break into the Reactor Cavity in Mode 3 FSAR FIG. 14.3.9-10 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 Containment Water Level: 6 Inch Break into the Reactor Cavity in Mode 3 FSAR FIG. 14.3.9-11 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 Time, Hours UFSAR Revision 30.0
16.4 REVISED PER 99-UFSAR-1197 RCS Pressure: 6 Inch Break into the Reactor Cavity in Mode 3 FSAR FIG. 14.3.9-12 SH 1 of 1 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN REV. NO.
DESCRIPTION REVISIONS TITLE DWG. NO.
UNIT 1 UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-13 Sheet 1 of 1
Title:
RECIRCULATION SUMP GENERAL ARRANGEMENT UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-14 Sheet 1 of 2
Title:
PREDICTED FLOW SPLIT THROUGH MAIN STRAINER 0
10 20 30 40 50 60 70 80 90 100 0
20 40 60 80 100 Main Strainer Open Area Ratio (%)
Flow Split through Main Strainer (%)
Dirty Case Clean Case 10% Case UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-14 Sheet 2 of 2
Title:
STRAINER SYSTEM HEAD LOSS AS FUNCTION OF MAIN STRAINER BLOCKAGE 0.0 0.5 1.0 1.5 2.0 2.5 3.0 0
20 40 60 80 100 Main Strainer Open Area Ratio (%)
Head Loss through System (ft-H 2O)
Dirty Case Clean Case 10% Case UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-15 Sheet 1 of 1
Title:
DEGB Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-16 Sheet 1 of 1
Title:
DEGB Event Sequence Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-17 Sheet 1 of 1
Title:
DEGB Debris Sequence Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-18 Sheet 1 of 1
Title:
DGBS Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-19 Sheet 1 of 1
Title:
DGBS Event Sequence Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-20 Sheet 1 of 1
Title:
DGBS Debris Sequence Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-21 Sheet 1 of 1
Title:
DEGB MFTL Chemical Effects Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-22 Sheet 1 of 1
Title:
DGBS MFTL Chemical Effects Head Loss Test Results UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-23 Sheet 1 of 2
Title:
30 Day Chemical Effects Head Loss Testing Pressure Drop Time History UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-23 Sheet 2 of 2
Title:
30 Day Chemical Effects Head Loss Testing Pressure Drop Time History UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-24 Sheet 1 of 1
Title:
ECCS Recirculation Flow Path LOOP 4 LOOP 1 LOOP 2 LOOP 3 LOOP 1 LOOP 4 E
N Upper Containment RHR Spray Header E
W RECIRC.
SUMP East RHR HX West RHR HX RCS COLD LEGS RCS HOT LEGS Charging Pumps RHR Pumps SI Pumps Outside Containment Inside Containment Boron Injection Tank 900 Gal.
UFSAR Revision 30.0
Revision: 22 Change
Description:
UCR-1917 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN UFSAR Figure: 14.3.9-25 Sheet 1 of 1
Title:
CTS Recirculation Flow Path EDUCTOR EDUCTOR East Containment Spray Pump West Containment Spray Pump Recirc Sump To RHR To RHR Recirc Sump ESW ESW ESW ESW SPRAY ADDITIVE TANK Lower Containment Volume Upper Containment Volume West RHR East RHR UFSAR Revision 30.0