MONTHYEARML23107A0262023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 3, Reactor ML23107A0552023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 2, Tables ML23107A0202023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 12, Figures ML23107A0502023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 2, Site and Environment ML23107A0542023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 1, References ML23107A0462023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 7, Appendices ML23107A0402023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 1, Figures ML23107A0592023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 1, Tables ML23107A0472023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 13, Initial Tests and Operations ML23107A0572023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 10, Figures ML23107A0352023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 8, References ML23107A0342023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 9, References ML23107A0382023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 8, Electrical Systems ML23107A0302023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 11, Tables ML23107A0132023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 5, Design of Structures, Systems, and Components ML23107A0452023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 11, References ML23107A0312023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 12, Conduct of Operations ML23107A0422023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 9, Tables ML23107A0562023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 4, Primary Coolant System ML23107A0192023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 10, Tables ML23107A0232023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 5, Figures ML23107A0152023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 6, Engineered Safeguards Systems ML23107A0122023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 2, Figures ML23107A0292023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 8, Figures ML23107A0162023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 5, Tables ML23107A0272023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 10, Steam and Power Conversion System ML23107A0252023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 11, Radioactive Waste Management and Radiation Protection ML23107A0612023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 1, Introduction & General Description of Plant ML23107A0282023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, List of Effective Pages ML23107A0242023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 15, Figures ML23107A0392023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 15, Quality Assurance Program ML23107A0482023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 6, References ML23107A0172023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 8, Tables ML23107A0492023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 7, References ML23107A0322023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 4, Tables ML23107A0332023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Table of Contents ML23107A0582023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 6, Figures ML23107A0182023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 7, Figures PNP 2023-002, 6 to Updated Final Safety Analysis Report2023-03-31031 March 2023 6 to Updated Final Safety Analysis Report ML23107A0142023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 14, Figures ML23107A0412023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 11, Figures ML23107A0522023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 3, Tables ML23107A0532023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 14, Safety Analysis ML23107A0432023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 2, References ML23107A0602023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 9, Auxiliary Systems ML23107A0362023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 3, Figures ML23107A0372023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 14, Tables ML23107A0512023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 6, Tables ML23107A0212023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 7, Instrumentation and Controls ML23107A0222023-03-31031 March 2023 6 to Updated Final Safety Analysis Report, Chapter 9, Figures 2023-03-31
[Table view] |
Text
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM TABLE 10-1 Revision 23 Page 1 of 1 TURBINE CASING PROPERTIES Tensile Strength, psi, Min 70,000 Yield Strength, psi, Min 36,000 Elongation in 2 Inches, %, Min 22 Reduction of Area, %, Min 35
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM TABLE 10-2 Revision 23 Page 1 of 1 STUD MECHANICAL PROPERTIES Size, Inches 2-1/2 Over 2-1/2 Over 4 and Less to 4 to 7 Tensile Strength, psi, Min 125,000 115,000 110,000 Yield Strength, psi, Min (0.2% Offset) 105,000 95,000 85,000 Elongation in 2 Inches, %, Min 16 16 16 Reduction of Area, %, Min 50 50 45
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM TABLE 10-3 Revision 28 Page 1 of 1 SIGNAL SYSTEM OPERATING CONDITIONS
- 1.
Hydrogen Purity - High or Low
- 2.
Hydrogen Pressure - High or Low
- 3.
Hydrogen Supply Pressure - Low
- 4.
Water Detection - High
- 5.
Hydrogen Temperature High / Generator Condition Monitor
- 6.
Defoaming Tank Level - High
- 7.
Seal Oil System Trouble
- 8.
Loss of Alarm DC Power
- 9.
Air Side Seal Oil Backup Pump Running
- 10.
+24 VDC Power - Off (Alarm Panel)
- 11.
Main Seal Oil Pump - Off
- 12.
Seal Oil Drain Tank Level - Error
- 13. Seal Oil Drain Tank Level - High
- 14.
Seal Oil Drain Tank Level - Low
- 15.
Seal Oil Drain Tank Level - Very Low
- 16.
Seal Oil Pressure - Low
- 17.
Seal Oil Turbine Backup Supply Pressure - Low
- 18.
TE or EE Seal Oil Pressure - Low
- 19.
Seal Oil Filter Differential - High
- 20.
PLC Failure
- 21.
Recirc Sol Valve Backup Mode - On
- 22.
Both Recirc Sol Valves - Closed
- 23.
125 VDC Power Supply Failure
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM TABLE 10-4 Revision 34 Page 1 of 2 COOLING TOWER DESIGN
SUMMARY
(SPX MARLEY TOWER E-30A)
Number of Towers 1
Number of Cells 16/Tower Type Induced/Cross Flow Performance at Design Point Hot Water Flow, gpm 185,000 Approach Temperature, °F 112.77 Range, °F 32 Cold Water Temperature, °F 80.77 Fan Brake Horsepower, bhp 166 Pumping Head Above Sill, ft 90 Fans and Fan Motors Number of Fans 16 Number of Blades 9
Blade Diameter, ft 28 Blade Material Fiberglass Reinforced Vinyl Ester Tip Speed, ft/s 196 Fan Speed, r/min 134 Rated hp/Voltage 200/460V
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM TABLE 10-4 Revision 34 Page 2 of 2 COOLING TOWER DESIGN
SUMMARY
(SPX MARLEY TOWER E-30B)
Number of Towers 1
Number of Cells 18/Tower Type Induced/Cross Flow Performance at Design Point Hot Water Flow, gpm 185,000 Approach Temperature, °F 110.9 Range, °F 32 Cold Water Temperature, °F 78.9 Fan Brake Horsepower, bhp 166 Pumping Head Above Sill, ft 90 Fans and Fan Motors Number of Fans 18 Number of Blades 9
Blade Diameter, ft 28 Blade Material Fiberglass Reinforced Vinyl Ester Tip Speed, ft/s 196 Fan Speed, r/min 134 Rated hp/Voltage 200/460V
FSAR CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM TABLE 10-5 Revision 23 Page 1 of 1 COOLING TOWER PUMPS Number of Pumps 2
Type Vertical, Wet Pit Design Flow, gpm 164,000 Design Head, ft 87 Design NPSH, ft 29 Pump Speed, r/min 253 Motor Type Induction Horsepower, hp 7,000 Voltage 4,160