~Entergx PNP 2021-003 March 25, 2021 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
2020 Steam Generator Tube Inspection Report Palisades Nuclear Plant NRC Docket 50-255 Renewed Facility Operating License No. DPR-20 Entergy Nuclear Operations, Inc.
Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, Ml 49043-9530 Tel 269-764-2000 Barbara E. Dotson Manager Regulatory Assurance 10 CFR 50.4 In accordance with Palisades Nuclear Plant (PNP) Technical Specifications Section 5.6.8, Steam Generator Tube Inspection Report, Entergy Nuclear Operations, Inc. is providing the enclosed 2020 steam generator tube inspection report. The specification requires that the report be submitted within 180 days after initial entry into mode 4 following completion of the inspection. Mode 4 was entered on October 18, 2020.
This letter contains no new commitments and no revised commitments.
Should you have any questions or require additional information, please contact Jim Miksa, regulatory assurance engineer at (269) 764-2945.
Respectfully, Barbara E. Dotson BED/jpm
Enclosure:
Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report, Framatome Inc., Engineering Information Record, Document No.:
51-9321268-000
PNP 2021-003 Page 2 of 2 cc:
NRC Region Ill Regional Administrator NRC Senior Resident Inspector - Palisades Nuclear Plant NRC Project Manager - Palisades Nuclear Plant
Enclosure to PNP 2021-003 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Framatome Inc.
Engineering Information Record Document No.: 51-9321268-000 70 pages follow
e 20004-026 (08/12/2020)
Framatome Inc.
Engineering Information Record Document No.:
51 9321268 -
000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Page 1 of 70
framatome 20004-026 (08/12/2020)
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Safety Related?
IX! YES NO Does this document establish design or technical requirements?
Does this document contain assumptions requiring verification?
Does this document contain Customer Required Format?
!XiNO Signature Block Pages/Sections Name and P/LP, R/LR, M, Prepared/Reviewed/
Title/Discipline Signature A-CRF,A Date Approved or Comments Craig Kelley CJ KELLEY p
Supervisory Engineer 2/17/2021 Chuck Martin CE MARTIN R
Advisory Engineer 2/18/2021 Wayne Belden WDBELDEN A
Technical Manager, SG Performance 2/18/2021 Engineering Note: P/LP designates Preparer (P), Lead Preparer (LP)
M designates Mentor (M)
R/LR designates Reviewer (R), Lead Reviewer (LR)
All All All A-CRF designates Project Manager Approver of Customer Required Format (A-CRF)
A designates Approver/RTM - Verification of Reviewer Independence Project Manager Approval of Customer References (N/A if not applicable)
Name Title (printed or typed)
(printed or typed)
Signature PM ULMER Paul Ulmer Project Manager 2/18/2021 Date Page2
framatome 20004-026 (08/12/2020)
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Record of Revision Revision Pages/Sections/
No.
Paragraphs Changed Brief Description / Change Authorization 000 All Original Document Page 3
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table of Contents Page SIGNATURE BLOCK................................................................................................................................ 2 RECORD OF REVISION.......................................................................................................................... 3 LIST OF TABLES..................................................................................................................................... 5 LIST OF FIGURES................................................................................................................................... 6 1.0 PURPOSE..................................................................................................................................... 7 2.0 ASSUMPTIONS............................................................................................................................ 7 3.0 INPUTS......................................................................................................................................... 7 4.0 180-DAY REPORT CONTENTS................................................................................................... 7 4.1 a) The scope of inspections performed on each SG......................................................... 9 4.2 b) Active Degradation Mechanisms Found..................................................................... 12 4.3 c) Nondestructive examination techniques utilized for each degradation....................... 12 4.4 d) Location, orientation (if linear), and measured sizes (if available) of service induced indications.......................................................................................................... 16 4.5 e) Number of tubes plugged during the inspection outage for each degradation mechanism...................................................................................................................... 21 4.6 f) The number and percentage of tubes plugged to date................................................ 23
- 4. 7 g) The results of condition monitoring, including the results of tube pulls and in-situ testing....................................................................................................................... 24 4.8 h) The effective plugging percentage for all plugging in each SG................................... 24 4.9 i) The results of monitoring for tube axial displacement (slippage)................................. 24
5.0 REFERENCES
............................................................................................................................ 25 APPENDIX A:
ACRONYMS AND ABBREVIATIONS..................................................................... A-1 APPENDIX B:
STEAM GENERATOR LAYOUT AND NOMENCLATURE..................................... 8-1 APPENDIX C: SUPPORT WEAR LISTING - SGA............................................................................. C-1 APPENDIX D : SUPPORT WEAR LISTING - SGB............................................................................. D-1 Page4
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report List of Tables Page Table 4-1: Refueling Outage (RFO) Information Since SG Replacement............................................... 8 Table 4-2: Eddy Current Tube Inspection Scope..................................................................................... 9 Table 4-3: 1 R27 Active Degradation Mechanisms................................................................................. 12 Table 4-4: ECT Technique Table........................................................................................................... 13 Table 4-5: 1 R27 Axial ODSCC Indications............................................................................................ 17 Table 4-6: 1R27 Axial PWSCC lndications............................................................................................ 18 Table 4-7: 1 R27 Circumferential ODSCC lndications............................................................................ 19 Table 4-8: Foreign Object Wear Indications (Volumetric) - No Object Present..................................... 20 Table 4-9: Diagonal Bar Wear Summary............................................................................................... 20 Table 4-10: Vertical Strap Wear Summary............................................................................................ 20 Table 4-11: Eggcrate Wear Summary................................................................................................... 20 Table 4-12: Tubes Affected by Support Wear........................................................................................ 21 Table 4-13: 1 R27 Tube Plugging........................................................................................................... 21 Table 4-14: 1R27 SGA Tubes Plugged................................................................................................. 22 Table 4-15: 1R27 SGB Tubes Plugged................................................................................................. 23 Table 4-16: Number and Percent of Tubes Plugged............................................................................. 24 Table B-1: Palisades SG Tube Support Structure Nomenclature........................................................ B-2 Page 5
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report List of Figures Page Figure 4-1: 1 R27 Inspection Summary.................................................................................................. 11 Figure 8-1: General Layout of Palisades SG Tube Support Structures............................................... 8-1 Figure 8-2: Palisades SG Tubesheet Map.......................................................................................... 8-2 Page6
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report 1.0 PURPOSE The purpose of this document is to provide the 1 R27 steam generator (SG) tube inspection report in accordance with Palisades Technical Specification 5.6.8, "Steam Generator Tube Inspection Reports" [3]. The report is provided in its entirety in Section 4.0 and the appendices of this document, from which it may be copied and modified as necessary by the Palisades Licensing Department.
2.0 ASSUMPTIONS This document contains no assumptions.
3.0 INPUTS The information summarized in this report was extracted from References [ 1 ], and [ 4].
4.0 180-DAY REPORT CONTENTS Palisades Technical Specification (TS) 5.6.8, Steam Generator Tube Inspection Reports [3], requires Entergy Nuclear Operations, Inc. (ENO), to submit a report to the Nuclear Regulatory Commission (NRC) within 180 days after initial entry into mode 4 following a steam generator inspection performed in accordance with TS 5.5.8, Steam Generator (SG) Program. The report is required to address the following items:
- a.
The scope of inspections performed on each SG.
- b. Active degradation mechanisms found.
- c.
Nondestructive examination techniques utilized for each degradation mechanism.
- d.
Location, orientation (if linear), and measured sizes (if available) of service induced indications.
- e.
Number of tubes plugged during the inspection outage for each degradation mechanism.
- f.
The total number and percentage of tubes plugged to date.
- g.
The results of condition monitoring, including the results of tube pulls and in-situ testing.
- h. The effective plugging percentage for all plugging in each SG.
- 1.
The results of monitoring for tube axial displacement (slippage).
If slippage is discovered, the implications of the discovery and corrective action shall be provided.
Entergy and Framatome performed a SG inspection in accordance with TS 5.5.8 during the Palisades Fall 2020 refueling outage (I R27). The Palisades SGs had accrued 24.21 effective full power years (EFPY) of operation through the end of cycle 27 (i.e., 1R27) per latest cycle lengths [l] with a nominal hot leg temperature of 583°F.
This inspection was the 19th in-service inspection following SG replacement and the 3rd and final scheduled inspection in the fifth sequential inspection period (Table 4-1 ). Initial entry into mode 4 occurred on October 18, 2020; therefore, this report is required to be submitted by April 16, 2021.
The following section ("Background") briefly describes the Palisades SG design characteristics and operating history, while the subsequent Section 4.1 through Section 4.9 provides responses to each of the TS 5.6.8 questions. Appendix A provides definitions for the acronyms and abbreviations used in this report.
Background
Palisades is a Combustion Engineering (CE) PWR equipped with two CE Model 2530 replacement steam generators. These steam generators were installed in the early l 990's as replacements for the original steam generators. Each steam generator contains 8219 Inconel 600 tubes with an outer diameter of 0. 75 inches and Page 7
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report nominal wall thickness of 0.042 inches. The tubes are arranged in a I-inch triangular-pitch pattern comprised of 138 rows and 165 columns. The tubes in rows 1 through 18 are ofu-bend design with a minimum bend radius of 2.5 inches (row 1) and maximum radius of 11 inches (row 18). The tubes in Rows 19 through 138 are of"square-bend" design consisting of two 90 degree bends of constant radius with a straight horizontal section of tubing of varying length between the two bends. The tubes were explosively expanded throughout the full tubesheet depth and are supported by several structures which include horizontal eggcrate supports, diagonal bars, and vertical strap supports. All of the support structures were fabricated with stainless steel. The general layout of the steam generator internals and associated nomenclature are provided in Appendix B.
Table 4-1: Refueling Outage (RFO) Information Since SG Replacement First Second Third Fourth Fifth Outage Cycle Cumulative Inspection Inspection Inspection Inspection Inspection Outage Period Period Period Period Period Year EFPD EFPY (EFPMs)
(EFPMs)
(EFPMs)
(EFPMs)
(EFPMs) 1R9 1992 298.5 0.82 9.81 1R10 1993 356.8 1.79 11.72 1 R11 1995 430.4 2.97 25.86 1R12 1996 407.8 4.09 39.26 1R13 1998 424.2 5.25 53.2 1R14 1999 449.6 6.48 7.97 1R15 2001 402 7.58 21.18 1R16 2003 444.5 8.80 35.78 1R17 2004 493.1 10.15 51.98 1R18 2006 472 11.44 7.49 1R19 2007 459.2 12.70 22.57 1R20 2009 499.8 14.07 39.00 1R21 2010 507.7 15.46 55.68 1R22 2012 495.3 16.81 11.95 1R23 2014 513.3 18.22 28.81 1R24 2015 539.4 19.70 46.53 1R25 2017 533.1 21.15 4.05 1R26 2018 503.0 22.53 21.03 1R27 2020 596.7 24.16 40.64 1R28(1)(2l 2022(2) 610.0(2) 25.834(2) 60.68(2)
Notes:
- 1.
Estimate
- 2.
Permanent shutdown and decommissioning is planned after the completion of the fuel cycle 28. No inspections are planned or required after 1 R27. The cycle length and a 1 R28 outage are shown only to illustrate regulatory compliance for operating duration.
EFPD = effective full power days EFPM = effective full power months EFPY = effective full power years Page 8
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report 4.1 a) The scope of inspections performed on each SG The IR27 work scope in both SGs (SGA and SGB) included eddy current (ECT) inspections, primary side visual inspections, and secondary side visual inspections. Figure 4-1 details all ECT and plug visual inspections performed.
ECT Inspection A summary of the ECT inspections performed is provided in Table 4-2.
Table 4-2: Eddy Current Tube Inspection Scope Scope Probe Type SGA 5GB Full Length (Note 1)
Bobbin 100%
100%
Row 1 through 3 U-bends MRPC 100%
100%
Hot Leg Tubesheets TTS+4"/-13.5" MRPC 100%
100%
Cold Leg Outer Three Periphery Tubes TTS+4"/-2" for detection of possible loose MRPC 12.2%
12.7%
parts or wear signals (Note 2)
Freespan Dings >5.0 Volts between TSH MRPC 100%
100%
and TSC Dents >2.0 Volts at Vertical Straps, Diagonal MRPC 100%
100%
Bars & Eggcrates between TSH and TSC Wear at Eggcrates (Current and Historical)
MRPC 100%
100%
Historical Wear at Diagonal Bars and MRPC 25%
25%
Vertical Straps Supplemental (Note 3)
MRPC 100%
100%
Notes:
- 1.
Except for the bend portion of rows I through 3.
- 2.
The values shown are percentages of the installed tube population.
- 3.
All DDI, DSI, NQI, PLP (Bound MRPC PLPs), PVN and new wear indications.
Primary Side Visual Inspections The primary side work activities include visual examination of the primary channel head and all installed tube plugs. The purpose of the as-found and as-left visual examination of the primary channel heads (both H/L and C/L) is to assess general material condition, to identify and remove foreign objects, if any and to complete the cladding inspection in accordance with the Framatome procedure for bowl inspections to address Nuclear Safety Advisory Letter NSAL-12-1. Additional detail is available in Reference [ 1]. No anomalous conditions were identified during these inspections. All plugs were present in the proper location and no degradation was observed.
Page 9
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Secondary Side Scope The secondary side work activities performed during the 1 R27 outage included a visual inspection and foreign object search and retrieval (FOSAR) at the top-of-tubesheet (TTS) in the tube-to-shell annulus and divider lane.
All visually-accessible passages between tubes were viewed from the tube bundle periphery on each leg. All findings were documented in the Framatome foreign object tracking system (FOTS).
Additional detail is available in Reference [ 1]
Page 10
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Figure 4-1: 1 R27 Inspection Summary 9/14/2020 7:39 AM
~::-;::-Entergy Palisades Unit 1 RF027 ECT Final Status Report framatome Exams Exams Exams S/G Exam Type Planned Acquired Evaluated Complete A
Bobbin - Full Length 7247 7247 7247 10000%
A Bobbin - H/L Straights Rows 1-6 342 342 342 100.00%
A Bobbin - C/L Straights Rows 1-3 171 171 171 100.00%
A Bobbin - C/L CandyCane Rows 4-6 171 171 171 100.00%
A RPG H/L Top ofTubesheet 7589 7589 7589 100.00%
A RPG C/L Top of Tubesheet 956 956 956 100.00%
A RPG Row 1-3 U-Bend 171 171 171 100.00%
A RPC SI H/L DNG/DNT/TRA 21 21 21 100.00%
A RPG SI C/L ONG/ONT/TRA 48 48 48 100.007~
A RPG SIU-Bend ONG/DNT/TRA 966 966 966 100.00%
A RPG SI U-Bend 25% Wear Sample 187 187 187 100.00%
Total Tests All Programs 17869 17869 17869 100.00%
B Bobbin - Full Length 7402 7402 7402 100.GD'}O B
Bobbin - H/L Straights Rows 1-6 351 351 351 100.00%
B Bobbin - C/L Straights Rows 1-3 172 172 172 10000%
B Bobbin - C/L CandyCane Rows 4-6 179 179 179 100.00%,
B RPG H/L Top of Tubesheet 7753 7753 7753 10000%
B RPG C/L Top of Tubesheet 987 987 987 100.00°;0 B
RPC Row 1-3 U-Bend 172 172 172 100.G0%
B RPG H/L Square Bend Bound 99-140 (07H-VS2) 3 3
3 100.00%
B RPC Restricted tube 62-139 (06C-06H) 1 1
1 100.t:)070 B
RPG SI H/L DNG/ONT/TRA 33 33 33 100.00S--o B
RPG SI C/L DNG/ONT/TRA 35 35 35 100 00%
B RPG SI U-Bend DNG/DNT/TRA 532 532 532 100.DO~lo B
RPG SIU-Bend 25% Wear Sample 199 199 199 100.00%
Total Tests All Programs 17819 17819 17819 100.00%
Seecial Interest +Point Diagnostic Exams Exams Exams Exams Planned Acquired Evaluated Complete A
RPG H/L I-Codes/TSP% TW/New ONT-ONG 484 484 484
'l00.00%
A RPC C/L I-Codes/TSP% TW/New ONT-ONG 510 510 510 100.00%
A RPG U-Bend I-Codes/New DNT,DNG,%TW 45 45 45 10000%
A Total Tests All SI Programs 1039 1039 1039 100 OOo/v B
RPC H/L I-Codes/TSP% TW/New ONT-ONG 366 366 366 10000%
B RPG C/L I-Codes/TSP% TW/New ONT-ONG 532 532 532 100 00°;;,
B RPC U-Bend I-Codes/New ONT.ONG,% TW 19 19 19 100.00%
Total Tests All SI Programs 917 917 917 100 00%,
ADDITIONAL INFORMATION Plugs Plugs Planned Inspected Complete A
H/L Plugs Visual Exam 630 630 100.00%
A C/L Plugs Visual Exam 630 630 100.uoc/o B
H/L Plugs Visual Exam 466 466 100.00%
B C/L Plugs Visual Exam 466 466 100.00%
Reeair Candidates S/GA S/GB Total Bobbin >= 40%
1 1
+Point I-Codes 31 23 54 Preventative Tube Plut:J 4
4 8
Total New Tubes to Plug 36 27 63 Prior Pluqqed Tubes 630 466 1096 Total Committed Pfu<1<1ed Tubes 666 493 1159 Page 11
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report 4.2 b) Active Degradation Mechanisms Found Degradation identified in 1R27 included corrosion-related cracking coincident with structures and in the freespan, and mechanical wear. Degradation identified was predicted and addressed in the Degradation Assessment [4].
Table 4-3 lists the degradation identified at 1R27.
Table 4-3: 1R27 Active Degradation Mechanisms SG Location Damage Mechanism Both Diagonal Bar (DB) Support Wear Both Vertical Strap (VS) Support Wear Both Eggcrate (EC) Support Wear Both Foreign Object (FO) on TTS (Note 1)
Wear Both Hot Leg EC Supports Axial ODSCC SGA Dented VS Support Axial ODSCC Both Hot Leg Top-of-Tubesheet (TTS)
Axial ODSCC Both Hot Leg Top-of-Tubesheet (TTS)
Circumferential ODSCC SGB Hot Leg Tubesheet Expansion Axial PWSCC Notes:
- 1.
All Foreign Object Wear identified in 1 R27 was historical with the object having been removed in a prior inspection.
4.3 c) Nondestructive examination techniques utilized for each degradation Nondestructive examination utilized during the 1 R27 inspection and their corresponding intended degradation mechanisms are given in Table 4-4.
Page 12
fram~atome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-4: ECT Technique Table Degradation Probe EPRI Demonstrated Applicability Extended Detection?
Sizing?
Mechanism Type ETSS Aoolicability BOBBIN PROBE Tube to Tube Bobbin 13091.1 Freespan tube-to-tube wear U-bends Yes Yes Wear Rev. O 128413 Freespan (excluding u-bend),
Axial ODSCC Bobbin Rev. 5 eggcrate, sludge pile, & broached None Yes No TSPs with or without dents :.2Voo Axial ODSCC Bobbin 24013.1 Freespan including dings :.5V None Yes No Rev. 2 Foreign 27091.2 Foreign object wear Extended for Bobbin 1-600 tubing with Yes Yes (Note 1)
Object Wear Rev. 2 (part not present); 1-690 tubing oart oresent Support Wear Bobbin 96004.1 AVBs, TSPs, Dents <5V Yes Yes Rev. 13 vertical straps, and diagonal bars Pitting Bobbin 96005.2 Freespan in the Sludge Pile Yes Yes Rev. 9 oresence of coooer AXIALODSCC 128424 Rev.4 Depth: Yes (detect);
TSP (with or without dents Axial ODSCC
+Point' None Yes BED: Yes 128431
<=2vpp) and sludge pile Rev. 3 BEL: Yes (sizini:i) 128425 Rev. 4 Depth: Yes (detect)
Freespan (excluding u-bend),
Axial ODSCC
+Point' eggcrate, & broached TSPs with or None Yes BED: Yes 128432 without dents :.2Vpp Rev.2 BEL: Yes (sizini:i)
Axial ODSCC
+Point' 10411.1 Low Row U-bends Higher Row Yes Yes Rev. 0 U-bends 21409.1 Support structures, freespan, PDA: Info Axial ODSCC
+Point' U-bends Yes Rev. 7 sludge pile, & tubesheet crevice Leni:ith: Info PLP-RPT-20-00010 Rev. 0 Page 13
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Degradation Probe EPRI Demonstrated Applicability Extended Detection?
Sizing?
Mechanism Tvoe ETSS Anolicabilitv Freespan dings &
Depth: Info Axial ODSCC
+Point' 22401.1 Dented TSPs dented eggcrates, Yes Rev.4 diagonal bars and Length: Yes vertical straps AXIALPWSCC Depth: Yes Axial PWSCC
+Point' 20511.1 Expansion Transitions Tubesheet Yes PDA: Info Rev. 8 Lenqth: Yes 96703.1 Dents/Dings including Dented Depth: Yes Axial PWSCC
+Point' Tubesheet Yes Rev. 17 Supports Lenqth: Yes Axial PWSCC
+Point' 96511.2 Low Row U-bends Higher Row Yes Yes Rev. 16 U-bends CIRCUMFERENTIAL ODSCC 21410.1 U-bends, Depth: Info CircODSCC
+Point' Rev. 6 Expansion Transitions freespan dings, Yes Note 2 dented supports PDA: Yes CircODSCC
+Point' 22842.1 Dented Supports Freespan dings, Yes Length: Yes Rev.4 u-bends CIRCUMFERENTIAL PWSCC 111524 U-bends, CircPWSCC
+Point' Rev. O Expansion Transitions Dents/Dings, Yes No Tubesheet Depth: Yes Circ PWSCC
+Point' 20510.1 Expansion Transitions U-bends No (see PDA: Yes Rev. 7 111524)
Lenqth: Yes CircPWSCC
+Point' 96511.2 See "Axial PWSCC" section of this table Rev. 16 Depth: Yes CircPWSCC
+Point' 96701.1 Expansion Transitions Dents/Dings and No (see PDA: Yes Rev. 12 tubesheet 111524)
Lenqth: Yes WEAR Tube to Tube
+Point' 13901.1 Freespan tube-to-tube wear U-bends Yes Depth: Yes Wear Rev. 1 PLP-RPT-20-00010 Rev. 0 Page 14
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Degradation Probe EPRI Demonstrated Applicability Extended Detection?
Sizing?
Mechanism Type ETSS Aoolicabilitv Dented/non-10908.5 dented Supports, Wear
+Point' Rev. O AVBs Foreign object Yes Depth: Yes (App. I) wear (part present)
Foreign 27901 Foreign object wear Volumetric Object Wear
+Point' through Freespan Wear Yes Yes (Note 1) 27907 (part not present)
(part present)
PITTING Pitting
+Point' 21998.1 Volumetric in freespan Sludge Pile Yes Yes Rev.4 NOTES:
- 1.
Multiple ETSSs were available for depth sizing of foreign object wear, each depending on the shape of the wear scar and the coil being used.
- 2.
The sizing performance of ETSS H-21410.1 with respect to circumferential depth profiling of ODSCC is described by EPRI TR-107197-P1, which utilized the same sizing methodology as ETSS H-21410.1. The performance parameters are as follows: Depth
= 1.0*NDE, Sv,x = 13.8; PDA = 1.05*NDE - 0.011, Sv,x = 13.43.
PLP-RPT-20-00010 Rev. 0 Page 15
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report 4.4 d) Location, orientation (if linear), and measured sizes (if available) of service induced indications The location, orientation, and measured size of axial ODSCC, axial PWSCC, circumferential ODSCC, and foreign object wear indications identified during the 1 R27 outage are provided in Table 4-5, Table 4-6, Table 4-7, and Table 4-8 respectively. Due to the large number support wear indications, the required data is provided in Appendix C and Appendix D.
Statistical summaries of throughwall depth, growth rates of support wear populations (i.e., diagonal bar, vertical strap, and eggcrate wear), and the number of tubes affected by support wear are provided in Table 4-9, Table 4-10, Table 4-11, and Table 4-12. In these tables, "New" refers to support wear indications that were newly reported during the 1 R27 outage, and "Repeat" refers to support wear indications reported during previous outage inspection(s) and again measured during 1 R27.
Axial outside diameter stress corrosion cracking (ODSCC) trends were evaluated over the last six inspections.
The maximum detected depth was bounded by predictions of the previous operational assessment. The max depth and average depths continued to follow the same trend of the previous inspections and the number of indications is the most seen since 1R22. This is not unexpected and addressed in the multi-cycle probabilistic model used in section 9.2 of [I]. A comparison of 1R23, 1R24, 1R25, 1R26, and 1R27 eddy current results revealed no transients in signal amplitudes which would suggest a degradation of data quality, and innocuous indications which were not removed from service produced similar responses from outage to outage. In addition, measurements of signal noise in regions of interest within the SGs confirm that data quality has not deteriorated with time as discussed in detail in section 9.1 of [ 1].
Page 16
fram:atome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-5: 1 R27 Axial ODSCC Indications NOE Maximum Structural
+Point 300 kHz Depth (%TW)
NOE Axial Structural Depth (%TW)
SG Row Col.
Location Amplitude (Vpp)
(Note 1)
Length (in.)
Length (in.)
(Note 1)
A 6
149 TSH -0.27 0.98 66.6 0.27 0.19 58.05 A
19 102 TSH -0.16 0.31 47.5 0.16 A
87 56 TSH-0.08 0.54 56.7 0.22 A
100 61 TSH -0.16 1.30 71.2 0.16 0.10 63.65 A
100 77 TSH -0.08 0.90 65.2 0.13 0.10 52.65 A
8 111 03H +0.51 0.40 48.8 0.69 0.28 42.04 A
16 43 0IH +l.00 0.41 49.3 1.71 0.33 48.23 A
16 127 03H +0.76 0.36 46.6 0.51 0.33 39.92 A
17 52 VS4 -0.02 0.44 50.8 0.17 0.15 51.90 A
27 106 02H-0.36 0.35 46.0 0.64 0.41 39.67 A
31 112 02H +0.18 0.39 48.3 0.56 0.23 41.37 A
32 123 04H -0.61 0.35 46.0 0.74 0.33 37.27 A
32 123 04H +0.69 0.32 44.2 0.56 0.33 39.05 A
50 95 0IH +0.56 0.63 58.3 0.59 0.38 54.20 A
63 72 0JH -0.59 0.34 45.4 0.64 A
93 92 0IH -0.25 0.34 45.4 0.89 0.66 37.84 A
111 I 12 0IH -0.43 0.26 39.8 0.79 0.38 36.61 A
133 94 0IH -0.38 0.44 50.8 0.71 0.46 42.40 B
23 48 TSH +0.48 0.51 55.8 0.46 0.28 41.29 B
29 32 TSH -0.22 0.41
- 52. l 0.16 B
29 50 TSH +0.89 0.76 62.4 0.30 0.28 49.38 B
21 112 0IH -0.58 0.33 44.8 0.53 B
29 108 0IH-0.20 0.53 54.7 0.41 B
29 116 0IH +0.48 0.52 54.3 0.41 PLP-RPT-20-00010 Rev. 0 Page 17
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report NOE Maximum Structural
+Point 300 kHz Depth (%TW)
NOE Axial Structural Depth (%TW)
SG Row Col.
Location Amplitude (Vpp)
(Note 1)
Length (in.)
Length (in.)
(Note 1)
B 31 106 05H -0.36 0.42 49.8 0.18 B
31 150 02H +0.18 0.49 53.1 0.80 0.28 46.34 B
32 155 02H -0.51 0.40 48.8 0.51 B
34 109 02H +0.71 0.40 48.8 0.30 B
34 115 0lH-0.05 0.35 46.0 1.32 B
41 148 02H +0.58 0.47 52.2 0.64 B
78 61 06C -0.54 0.39 48.3 0.99 B
79 46 07C -0.81 0.50 53.5 0.13 B
79 74 06H +0.80 0.29 42.1 0.49 B
79 96 0lH -0.61 0.48 52.6 0.81 0.38 47.51 B
80 41 05H -0.15 0.38 47.8 1.26 0.91 35.44 B
98 79 0lH -0.70 0.29 42.1 0.67 0.31 41.81 B
105 102 02H +0.64 0.22 36.3 0.28 Notes:
- 1.
The NDE maximum depth values were calculated using the Appendix I regression techniques (3/4TW as function ofNDE voltage) and then reduced by 11 3/4TW in accordance with Reference [2]. Both the NDE maximum depth and structural depth values, shown in this table, reflect the 11 % TW reduction.
Table 4-6: 1 R27 Axial PWSCC Indications
+Point 300 kHz NOE Maximum NOE Axial Structural Structural SG Row Col.
Location Amplitude (Vpp)
Depth (%TW)
Length (in.)
Length (in.)
Depth (%TW)
B 97 74 TSH-0.19 0.52 72.0 0.14 0.10 43.I Notes:
I.
All flaws were fully contained within the tubesheet expansion; therefore satisfying all performance criteria.
PLP-RPT-20-00010 Rev. 0 Page 18
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-7: 1 R27 Circumferential ODSCC Indications NDE Percent Degraded Area
+Point 300 kHz (PDA)
Circumferential SG Row Col Location Amplitude (Vpp)
(Note 1)
Length (in.)
A 27 52 TSH-0.08 0.65 2.93 0.34 A
32 53 TSH -0.08 0.32 2.97 0.47 A
35 54 TSH +0.05 0.59 3.87 0.25 A
36 53 TSH -0.08 0.66 2.24 0.59 A
40 55 TSH -0.05 0.50 3.72 0.27 A
48 51 TSH -0.03 0.60 2.22 0.42 A
55 60 TSH-0.08 0.81 5.33 0.56 A
56 109 TSH-0.08 0.57 0.93 0.54 A
61 62 TSH-0.08 0.29 2.11 0.17 A
82 83 TSH -0.21 0.70 7.38 0.47 A
94 69 TSH-0.11 0.60 3.72 0.25 A
95 62 TSH-0.05 0.40 2.32 0.25 A
97 60 TSH +0.05 0.64 7.44 0.71 A
106 71 TSH -0.11 0.37 1.68 0.22 B
97 70 TSH -0.08 0.81 6.73 0.52 B
97 72 TSH -0.05 0.55 5.28 0.79 B
98 73 TSH -0.05 0.84 1.18 0.20 B
98 73 TSH +0.03 0.53 1.68 0.20 Notes:
- 1.
The percent degraded area (PDA) of the circumferential indications was determined using the EPR1 Draw Program based on measurements from EPR1 ETSS H-21410.1.
PLP-RPT-20-00010 Rev. 0 Page 19
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-8: Foreign Object Wear Indications (Volumetric) - No Object Present Maximum Circumferential Axial SG Row Col.
Location Sizing ETSS Depth (3/4TW)
Extent (0 )
Extent (in.)
A 130 63 TSH +l.49 21998. l 19 44.3 0.29 B
137 92 TSH +10.14 21998.l 23 44.3 0.29 B
137 92 TSH +11.15 21998.I 23 44.3 0.29 Table 4-9: Diagonal Bar Wear Summary Number of New and Repeat Depths Growth Rate of Repeats Indications (3/4TW)
(3/4TW/EFPY)
SG New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A
3 118 15.4 30.0 39.0 0.4 3.1 5.5 B
0 100 15.7 26.1 30.0
-0.7 1.8 3.1 Both 3
218 15.5 28.0 39.0
-0. l 2.4 5.5 SGs Table 4-1 O: Vertical Strap Wear Summary Number of New and Repeat Depths Growth Rate of Repeats Indications (3/4TW)
(3/4TW/EFPY)
SG New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A
3 618 17.2 31.0 41.0
-0.2 1.8 4.3 B
6 690 19.2 31.0 39.0
-0.3 1.8 4.3 Both 9
1308 18.3 31.0 41.0
-0.3 1.8 4.3 SGs Table 4-11: Eggcrate Wear Summary Number of New and Repeat Depths Growth Rate of Repeats Indications (3/4TW)
(3/4TW/EFPY)
SG New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A
32 834 14.9 22.8 36.0
-0.3 1.8 3.7 B
9 826 15.5 23.0 37.0
-0.2 1.8 3.7 Both 41 1660 15.2 23.0 37.0
-0.3 1.8 3.7 SGs Page 20
e Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-12: Tubes Affected by Support Wear SG Diagonal Bar Wear Vertical Strap Wear Eggcrate Wear A
116 377 678 B
96 436 693 4.5 e) Number of tubes plugged during the inspection outage for each degradation mechanism Sixty-three (63) tubes were plugged during 1R27. Counts and degradation mechanisms are given in Table 4-13 below.
Note that Table 4-13 counts the number of tubes plugged per degradation mechanism. Table 4-14 and Table 4-15 list every flaw that exceeded plugging criteria.
Because some tubes contained more than one pluggable indication, the number of flaws on Table 4-14 and Table 4-15 is larger than the number of tubes plugged in Table 4-13 Table 4-13: 1R27 Tube Plugging SGA SGB Total Location Tubes Tubes Tubes Tubes Tubes Tubes Plugged Stabilized Plugged Stabilized Plugged Stabilized OD Axial at Support 11 0
16 0
27 0
OD Axial at Dented Support (Note 1) 1 0
0 0
1 0
OD Axial at TSH Transition / Sludge Pile 5
0 3
0 8
0 OD Circ in TSH Expansion Transition 14 14 3
3 17 17 ID Axial in TSH Expansion 0
0 1
0 1
0 Foreign Object (Note 2) 4 3
4 8
6
.)
Foreign Object Wear 0
0 0
0 0
0 Wear at Supports 1
0 0
0 1
0 Other 0
0 0
0 0
0 Total 36 17 27 6
63 23 Notes:
- 1.
In tube 17-52 in SGA an Axial ODSCC indication was identified at VS4 at the same location as a Dent which had a bobbin voltage of 1.81 volts and qualified for use (since< 2.0 volts).
- 2.
Four (4) tubes in SGA and four (4) tubes in SGB were preventatively plugged per request of Entergy to bound foreign objects [ 1, Appendix A and Appendix B]. Of those tubes, only three (3) were stabilized in each SG.
Page 21
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-14: 1R27 SGA Tubes Plugged Count 5/G Row Col Hot Leg Cold Leg Reason for Tube Repair 1
A 6
149 Rolled Plug Rolled Plug SAi @ TSH-0.27 2
A 8
111 Rolled Plug Rolled Plug SAi @ 03H+0.51 3
A 16 43 Rolled Plug Rolled Plug SAi@ 0lH+l.00 4
A 16 127 Rolled Plug Rolled Plug SAi@ 03H+0.76 5
A 17 52 Rolled Plug Rolled Plug SAi@ VS4-0.02 6
A 19 102 Rolled Plug Rolled Plug SAi @ TSH-0.16 7
A 27 52 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 8
A 27 106 Rolled Plug Rolled Plug SAi @ 02H-0.36 9
A 31 112 Rolled Plug Rolled Plug SAi @ 02H+0.18 10 A
32 53 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 11 A
32 123 Rolled Plug Rolled Plug SAi @ 04H-0.61 SAi @ 04H+0.69 12 A
35 54 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH+0.05 13 A
36 53 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 14 A
40 55 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.05 15 A
46 65 Rolled Plug Rolled Plug TWO @ VS4+0. 77 16 A
48 51 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.03 17 A
50 95 Rolled Plug Rolled Plug SAi @ 0lH+0.56 18 A
55 60 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 19 A
56 109 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 20 A
61 62 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 21 A
63 72 Rolled Plug Rolled Plug SAi @ 0lH-0.59 22 A
82 83 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.21 23 A
87 56 Rolled Plug Rolled Plug SAi @ TSH-0.08 24 A
93 92 Rolled Plug Rolled Plug SAi @ 0lH-0.25 25 A
94 69 Rolled Plug+ Stabilizer Rolled Plug SCI@ TSH-0.11 26 A
95 62 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.05 27 A
97 60 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH+0.05 28 A
100 61 Rolled Plug Rolled Plug SAi@ TSH-0.16 29 A
100 77 Rolled Plug Rolled Plug SAi @ TSH-0.08 30 A
106 71 Rolled Plug+ Stabilizer Rolled Plug SCI@ TSH-0.11 31 A
111 112 Rolled Plug Rolled Plug SAi @ 0lH-0.43 32 A
133 94 Rolled Plug Rolled Plug SAi @ 0lH-0.38 33 A
108 121 Rolled Plug Rolled Plug PTP for Foreign Object @ TSH 34 A
109 122 Rolled Plug+ Stabilizer Rolled Plug PTP for Foreign Object @ TSH 35 A
110 121 Rolled Plug+ Stabilizer Rolled Plug PTP for Foreign Object @ TSH 36 A
111 122 Rolled Plug+ Stabilizer Rolled Plug PTP for Foreign Object @ TSH Page 22
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-15: 1 R27 5GB Tubes Plugged Count S/G Row Col Hot Leg Cold Leg Reason for Tube Repair 1
B 21 112 Rolled Plug Rolled Plug SAi @ 0lH-0.41 2
B 23 48 Rolled Plug Rolled Plug SAi@ TSH+0.52 3
B 29 32 Rolled Plug Rolled Plug SAi @ TSH-0.20 4
B 29 50 Rolled Plug Rolled Plug SAi@ TSH+0.99 5
B 29 108 Rolled Plug Rolled Plug SAi @ 0lH-0.24 6
B 29 116 Rolled Plug Rolled Plug SAi @ 0lH+0.41 7
B 31 106 Rolled Plug Rolled Plug SAi @ 05H-0.36 8
B 31 150 Rolled Plug Rolled Plug SAi@ 02H+0.18 9
B 32 155 Rolled Plug Rolled Plug SAi @ 02H-0.52 10 B
34 109 Rolled Plug Rolled Plug SAi@ 02H+0.76 11 B
34 115 Rolled Plug Rolled Plug SAi@ 0lH+0.10 12 B
41 148 Rolled Plug Rolled Plug SAi @ 02H+0.55 13 B
78 61 Rolled Plug Rolled Plug SAi@ 06C-0.57 14 B
79 46 Rolled Plug Rolled Plug SAi @ 07C-0.94 15 B
79 74 Rolled Plug Rolled Plug SAi @ 06H+0.83 16 B
79 96 Rolled Plug Rolled Plug SAi @ 0lH-0.69 17 B
80 41 Rolled Plug Rolled Plug SAi@ 05H-0.18 18 B
97 70 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 19 B
97 72 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH+0.01 20 B
97 74 Rolled Plug Rolled Plug SAi @ TSH-0.20 21 B
98 73 Rolled Plug+ Stabilizer Rolled Plug SCI @ TSH-0.08 SCI@ TSH+0.00 22 B
98 79 Rolled Plug Rolled Plug SAi @ 0lH-0.58 23 B
105 102 Rolled Plug Rolled Plug SAi @ 02H+0.64 24 B
79 36 Rolled Plug Rolled Plug PTP for Foreign Object @ TSH 25 B
80 37 Rolled Plug+ Stabilizer Rolled Plug PTP for Foreign Object @ TSH 26 B
81 36 Rolled Plug+ Stabilizer Rolled Plug PTP for Foreign Object @ TSH 27 B
82 37 Rolled Plug+ Stabilizer Rolled Plug PTP for Foreign Object @ TSH 4.6 f) The number and percentage of tubes plugged to date The number of tubes plugged prior to 1R27, the number of tubes plugged in IR27 and the current total of tubes plugged, along with the corresponding percentages is given below in Table 4-16.
Page 23
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Table 4-16: Number and Percent of Tubes Plugged SGA SGB Total Total Tubes Installed 8219 8219 16438 Tubes Plugged Pre-Service 308 309 617 Tubes Plugged During Service through 1 R26 322 157 479 Tubes Plugged in 1R27 36 27 63 Total Tubes Plugged to Date 666 493 1159 Effective Tubes Plugged to Date 666 493 1159 Effective Plugging Percentage 8.1 6.0 7.1 4.7 g) The results of condition monitoring, including the results of tube pulls and in-situ testing Through a combination of eddy current inspection, analytical evaluation, and operational leakage monitoring, it has been determined that the three performance criteria (i.e., structural integrity, accident induced leakage integrity, and operational leakage integrity) were satisfied during the operating period prior to the I R27 outage.
All tubes satisfied performance criteria analytically.
No tube pulls were planned and none were performed.
The condition monitoring assessment concluded that the structural integrity criteria (TS 5.5.8b. l) and accident induced leakage performance criteria (TS 5.5.8b.2) were satisfied during the operating interval preceding 1R27.
Operational leakage monitoring during cycle 27 indicated stable, low level primary to secondary leakage. The indicated leakage was just above detectability with a maximum of 1.5 GPO during the cycle based on Xe-135 activity [I]. Consequently, the plant specific operational leakage performance criterion (150 GPO, TS 5.5.8b.3, LCO 3.4.13d) was also satisfied throughout the cycle.
4.8 h) The effective plugging percentage for all plugging in each SG Since no sleeving has been performed in the Palisades steam generators, the effective plugging percentage is the same as the actual plugging percentage (see Section 4.6).
4.9 i) The results of monitoring for tube axial displacement (slippage)
Potential tube axial displacement in the tubesheet (slippage or "pullout") was monitored. Algorithms were implemented in the ECT data analysis software to detect this condition. None was identified.
Page 24
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report
5.0 REFERENCES
References identified with an (*) are maintained within Entergy / Palisades Records System and are not retrievable from Framatome Records Management. These are acceptable references per Framatome Administrative Procedure 0402-01, Attachment 7. See page [2] for Project Manager Approval of customer references.
- 1.
Framatome Document 51-9321652-000 "Palisades Steam Generator Condition Monitoring for 1 R27 and Final Operational Assessment for Cycle 28"
- 2.
PNP 2012-021, April 5, 2012
- 3.
- Palisades Technical Specification (Administrative Controls), 5.5.8, "Steam Generator (SG) Program" (Includes Amendment No 225 and 261 to Renewed Facility Operating License No. DPR-20)
- 4.
Framatome Document 51-9311865-000, "Steam Generator Degradation Assessment for Palisades 1 R27 Inspection, Fall 2020" Page 25
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report APPENDIX A:
ACRONYMS AND ABBREVIATIONS Acronym Definition 0"x"H or 0"x"C Hot (H) or Cold (C) Leg Support Plate #x AVB Anti-Vibration Bar BED Burst Equivalent Depth BEL Burst Equivalent Length CMOA Condition Monitoring and Operational Assessment DOI Dent or Ding with Indication OSI Distorted Support Indication ETSS Examination Technique Specification Sheet FDMS AREVA Data Management System IGA lntergranular Attack LP Loose Part MRPC Motorized Rotating Pancake Coil (+Pt.')
MBM Manufacturing Burnish Mark NOD No Degradation Detected NOE Non Destructive Examination NQI Non-Quantifiable Indication NTE No Tube Expansion ODSCC Outside Diameter Stress Corrosion Cracking PDA Percent Degraded Area PLG Tube Is Plugged PLP Possible Loose Part PTE Partial Tube Expansion PTP Preventative Tube Plug PVN Permeability Variation PWR Pressurized Water Reactor PWSCC Primary Water Stress Corrosion Cracking SAi Single Axial Indication SCI Single Circumferential Indication SGA Steam Generator E-50A SGS Steam Generator E-508 SVI Single Volumetric Indication TSP To Be Plugged TSP Tube Support Plate TTS Top of Tubesheet TSC Tubesheet Cold (Leg)
TSH Tubesheet Hot (Leg)
TWO Through Wall Degradation
%TW Percent throughwall
<TS Less Than Techni~_".I Specification Plugging Limit VS"x" Vertical Strap #x WAR Wear Indication Page A-1
e Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report APPENDIX B:
STEAM GENERATOR LAYOUT AND NOMENCLATURE Figure B-1: General Layout of Palisades SG Tube Support Structures DBH OSH l 28.50
07H s+l*
06H 28.50" 28.50" 05H 39.75" 04H I 38.75" 03H 39.75" 02H*
I
/4 38.75" 01H !
1 28.00' TSH TEH 20.75"
.i
_ ___J i
DBC 08C 07C 06C 05C 04C 03C Page B-1
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Figure B-2: Palisades SG Tubesheet Map Table B-1: Palisades SG Tube Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top of Tubesheet - Hot Side VS5 Fifth Vertical Strap 01H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS7 Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side 08C Eighth Eggcrate - Cold Side 05H Fifth Eggcrate - Hot Side 07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side 05C Fifth Eggcrate - Cold Side 08H Eighth Eggcrate - Hot Side 04C Fourth Eggcrate - Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2 Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side Page B-2
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report APPENDIX C: SUPPORT WEAR LISTING - SGA Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1
A 1
128 02C 0.69 14 39 A
13 36 04H
-0.87 14 2
A 1
136 02H
-1.02 14 40 A
13 146 DBC
-1.17 14 3
A 1
150 01C
-0.16 13 41 A
14 3
02C 0.86 24 4
A 1
150 02C 0.76 22 42 A
14 117 01H 0.89 22 5
A 1
162 01C 0.83 11 43 A
15 116 03H 0.81 18 6
A 2
127 05C 0.7 22 44 A
15 154 DBC 1.69 15 7
A 2
159 03C
-0.21 14 45 A
16 113 02H
-0.46 14 8
A 3
128 02C 0.71 12 46 A
16 115 01H
-0.18 16 9
A 3
164 02C 0.76 10 47 A
18 51 VS4
-1.19 12 10 A
3 164 03H
-0.98 13 48 A
19 56 DBC 0.64 17 11 A
4 55 01H 0.8 13 49 A
19 64 DBC
-1.55 21 12 A
4 55 DBC 0.16 16 so A
19 64 DBH
-1.73 22 13 A
4 115 04C 0.85 13 51 A
22 3
02C
-0.94 12 14 A
4 137 02C 0.76 13 52 A
22 9
02C
-0.97 10 15 A
4 157 02C
-0.16 9
53 A
22 159 02H 1.01 14 16 A
4 157 02C 0.81 12 54 A
22 163 02H
-0.82 12 17 A
5 130 02C 0.73 10 55 A
24 33 01H 0.92 13 18 A
9 2
02C 0.14 16 56 A
24 159 02H 0.87 20 19 A
9 32 DBC 1.19 13 57 A
24 161 02C
-0.9 14 20 A
10 117 01H 0.84 17 58 A
24 161 02C 0.82 16 21 A
10 165 DBH 1.85 12 59 A
24 163 02C 0.87 20 22 A
11 114 01H 0.77 20 60 A
25 110 04C 0.76 14 23 A
11 114 02H 0.77 13 61 A
26 3
02C
-0.92 16 24 A
11 114 03H 0.9 15 62 A
26 51 02H 0.98 14 25 A
11 114 05H 0.78 19 63 A
26 117 01H 0.91 19 26 A
11 116 01H 0.89 20 64 A
26 161 03H 0.94 12 27 A
11 146 03C 0.81 13 65 A
26 163 01H 0.99 13 28 A
12 3
02C 0.74 18 66 A
27 6
02H
-0.8 10 29 A
12 19 03H
-0.25 17 67 A
27 8
02C
-0.92 10 30 A
12 113 01H 0.8 18 68 A
27 10 05H
-0.05 8
31 A
12 113 02H
-0.3 16 69 A
27 10 05H 0.92 8
32 A
12 131 03H 0.87 25 70 A
28 3
02C
-0.93 16 33 A
12 131 05H 0.86 23 71 A
28 19 VS4
-0.88 23 34 A
12 139 01H
-0.78 14 72 A
28 31 VS4
-0.84 26 35 A
12 139 03H 0.96 26 73 A
28 63 VS4
-0.79 14 36 A
13 2
02H
-0.82 10 74 A
29 162 01H
-0.84 12 37 A
13 2
02H 0.85 17 75 A
31 44 02C 0.83 10 38 A
13 34 03C
-1 18 76 A
31 126 VS4
-0.75 17 Page C-1
fram Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 77 A
31 126 VS4 0.32 10 117 A
38 35 03H 0.89 19 78 A
31 128 VS4
-0.82 17 118 A
38 35 04H 0.92 24 79 A
31 128 VS4 1.02 23 119 A
38 35 05H 0.91 17 80 A
32 7
02C
-0.95 22 120 A
38 51 04C 0.86 29 81 A
32 37 03H 0.99 17 121 A
38 127 03H 0.89 13 82 A
32 59 DSH 0.12 20 122 A
39 10 DBH 1.88 14 83 A
32 109 VS4
-0.24 11 123 A
39 14 05H
-0.09 11 84 A
32 145 VS4
-0.98 19 124 A
39 40 02H 0.91 9
85 A
33 22 DSH 1.95 15 125 A
39 112 02C 0.74 18 86 A
33 46 02H 0.89 14 126 A
39 120 04H 0.94 19 87 A
33 48 02H 1
11 127 A
39 126 03C 0.76 16 88 A
33 56 01H
-0.79 19 128 A
40 5
01C
-0.95 11 89 A
33 56 01H 0.93 17 129 A
40 59 05H 0.98 18 90 A
33 56 05H 0.84 16 130 A
40 125 02C 0.88 13 91 A
33 124 03C 0.89 17 131 A
40 147 VS4
-0.76 31 92 A
34 15 VS4
-0.92 11 132 A
40 147 VS4
-0.19 24 93 A
34 23 02H
-0.78 16 133 A
41 6
02C
-0.23 12 94 A
34 39 02H 0.89 8
134 A
41 8
02C
-0.21 12 95 A
34 63 DSC 1.59 12 135 A
41 16 05H
-0.78 15 96 A
34 109 04H 0.94 19 136 A
41 20 05H 0.9 12 97 A
34 117 03C
-0.93 15 137 A
41 22 05H
-0.78 9
98 A
34 119 03H 1
12 138 A
41 34 03H
-0.82 17 99 A
35 114 DSC 1.6 14 139 A
41 52 VS4
-0.85 27 100 A
36 153 VS4 0.81 11 140 A
41 60 05H 0.93 25 101 A
37 24 05C 0.85 16 141 A
41 108 03C 0.76 11 102 A
37 30 05H 0.85 11 142 A
41 126 02C
-0.98 15 103 A
37 34 04H 0.94 12 143 A
41 160 01H 0.95 15 104 A
37 34 DSC 1.64 17 144 A
41 160 03C
-0.12 10 105 A
37 36 04H
-0.11 13 145 A
42 5
VS4
-0.84 9
106 A
37 38 03C 0.81 18 146 A
42 5
VS4 0.1 12 107 A
37 56 04H 0.96 21 147 A
42 7
02C 0.84 18 108 A
37 62 04H 0.98 17 148 A
42 35 05C 0.88 13 109 A
37 62 05H
-0.74 15 149 A
42 41 VS4
-0.94 31 110 A
37 106 03C
-0.86 15 150 A
42 41 VS4 0.89 25 111 A
37 116 03C 0.83 13 151 A
42 43 04H 0.9 21 112 A
37 128 VS4
-0.9 16 152 A
42 59 04H 0.84 15 113 A
37 128 VS4 0.98 23 153 A
42 117 02C 0.79 17 114 A
37 134 03H 0.93 13 154 A
43 46 03H
-0.05 11 115 A
38 11 05H 0.89 11 155 A
43 46 VS4
-0.73 32 116 A
38 17 05H
-0.02 17 156 A
43 46 VS4 1.11 18 Page C-2
fram ome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 157 A
43 106 03C 0.79 14 197 A
47 112 02C 0.81 18 158 A
43 126 VS4 0.93 30 198 A
47 122 VS4 0.1 25 159 A
44 15 DSH
-1.1 18 199 A
47 122 VS4 0.93 30 160 A
44 21 VS4
-0.81 30 200 A
47 124 VS4 0.1 21 161 A
44 21 VS4
-0.19 20 201 A
47 124 VS4 0.93 23 162 A
44 21 VS4 0.76 26 202 A
47 126 VS4
-0.74 25 163 A
44 47 VS4
-0.63 15 203 A
47 126 VS4 0.07 25 164 A
44 49 04H 0.87 17 204 A
48 7
01C 0.79 25 165 A
44 49 05C
-0.88 19 205 A
48 19 VS4
-1.08 39 166 A
44 49 VS4
-0.73 29 206 A
48 19 VS4 0.55 30 167 A
44 49 VS4
-0.07 26 207 A
48 21 VS4
-0.88 27 168 A
44 109 03C 0.18 13 208 A
48 29 03C 0.76 17 169 A
44 123 06H
-0.32 20 209 A
48 29 04H 0.87 13 170 A
44 123 VS4
-0.52 22 210 A
48 41 VS4
-0.97 39 171 A
44 123 VS4 0.05 23 211 A
48 41 VS4 1.08 19 172 A
45 12 DSH 2.13 13 212 A
48 43 VS4
-0.94 35 173 A
45 30 04H
-0.84 15 213 A
48 43 VS4 0.25 7
174 A
45 42 VS4 0.64 13 214 A
48 43 VS4 0.91 18 175 A
45 52 03H 0.93 16 215 A
48 45 06H 0.91 11 176 A
45 60 04H 0.98 11 216 A
48 69 VS4
-0.85 11 177 A
45 108 03C 0.78 17 217 A
48 69 VS4 0.97 31 178 A
45 122 03C
-0.95 21 218 A
48 97 VS4 0.94 29 179 A
45 124 VS4 0.96 24 219 A
48 125 02C 0.14 14 180 A
45 134 03C 0.84 18 220 A
48 125 02C 0.7 16 181 A
46 37 03H 0.99 10 221 A
49 10 VS4 0.91 19 182 A
46 41 04H 0.96 9
222 A
49 20 VS4
-0.81 30 183 A
46 51 03H 1
14 223 A
49 20 VS4 1.06 24 184 A
46 53 VS4
-0.82 28 224 A
49 24 VS4
-0.88 16 185 A
46 53 VS4 0.97 23 225 A
49 28 03C 0.76 14 186 A
46 55 VS4
-0.93 17 226 A
49 28 DSC 1.32 12 187 A
46 55 VS4 1.01 23 227 A
49 36 03C 0.98 17 188 A
46 65 VS4 0.77 41 228 A
49 66 VS4 0.02 22 189 A
46 125 VS4 0.02 22 229 A
49 66 VS4 0.92 17 190 A
46 125 VS4 0.84 13 230 A
49 70 VS4 0.98 20 191 A
46 141 04C 0.79 18 231 A
49 74 DSC 1.49 17 192 A
47 8
01H
-0.84 17 232 A
49 74 VS4
-0.8 18 193 A
47 12 DBC 1.4 10 233 A
49 92 03C
-0.97 16 194 A
47 24 04H
-0.8 10 234 A
49 112 VS4
-0.68 12 195 A
47 50 VS4 1
14 235 A
49 112 VS4
-0.02 20 196 A
47 70 04H 0.96 20 236 A
50 21 DSC 1.34 11 Page C-3
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 237 A
50 45 VS5
-0.93 16 277 A
55 122 02C
-0.19 12 238 A
50 51 03H 0.93 13 278 A
55 140 06C
-0.21 18 239 A
50 91 VS4 0.94 17 279 A
56 39 04H 0
13 240 A
50 123 04C 0.05 16 280 A
56 41 02H
-0.09 12 241 A
50 127 03C
-0.88 11 281 A
56 81 DSH 1.85 20 242 A
50 143 VS3 0.86 12 282 A
56 115 02C 0.74 15 243 A
50 157 VS3
-0.73 37 283 A
56 137 03C 0.12 17 244 A
50 157 VS3 0.83 24 284 A
57 18 VS3
-0.57 15 245 A
51 16 VS4
-0.83 15 285 A
57 32 06H 0.06 11 246 A
51 20 VS3
-0.79 29 286 A
57 142 03C 0.84 18 247 A
51 70 05H 0.95 14 287 A
58 33 04H
-0.91 11 248 A
51 90 04C
-0.53 18 288 A
58 33 DSH 2.14 20 249 A
51 108 03C
-0.93 14 289 A
58 57 03H 0.95 10 250 A
51 118 02C
-0.9 18 290 A
58 85 03H 1
16 251 A
51 122 02C
-0.23 13 291 A
58 121 02C 0.81 13 252 A
51 124 04C
-0.9 9
292 A
58 127 04C 0.79 20 253 A
51 126 02C 0
15 293 A
59 30 03C 0.79 14 254 A
51 126 02C 0.74 10 294 A
59 38 03H 0.86 11 255 A
51 126 03C
-0.95 11 295 A
59 56 DSH
-0.75 13 256 A
51 134 VS3
-0.85 14 296 A
59 106 02C 0.83 15 257 A
52 9
01C
-0.95 11 297 A
60 25 04H 0.94 15 258 A
52 31 03C 0.84 16 298 A
60 29 04H 0.91 18 259 A
52 111 02C 0.77 17 299 A
60 33 DSC 1.32 14 260 A
52 117 02C 0.76 19 300 A
60 39 04H 1.01 11 261 A
52 149 VS3 1.15 17 301 A
60 119 02C 0.9 21 262 A
53 10 01C
-0.95 16 302 A
60 121 02C 0.88 20 263 A
53 56 03H 1.02 15 303 A
61 20 DSC 1.1 8
264 A
53 92 03C 0.79 17 304 A
61 34 03H 0.94 11 265 A
53 118 02C 0.7 12 305 A
61 44 04H
-0.07 12 266 A
53 122 02C
-0.28 22 306 A
61 48 06H 1
11 267 A
54 29 02C 0.74 17 307 A
61 112 04C
-1.02 14 268 A
54 33 03H 0.98 12 308 A
61 138 DSC 1.56 14 269 A
54 39 03H 0.89 11 309 A
61 150 DSC 1.35 11 270 A
54 81 DSH 1.71 23 310 A
62 11 01C
-0.93 16 271 A
54 83 03H 0.96 17 311 A
62 15 06C 0.89 13 272 A
54 83 DSH
-0.07 39 312 A
62 19 06H 0.94 13 273 A
54 119 02C 0.77 14 313 A
62 33 03H
-0.82 10 274 A
55 8
01C
-0.23 13 314 A
62 33 03H 0.89 18 275 A
55 88 02C
-1 12 315 A
62 35 03H 0.98 12 276 A
55 120 02C
-0.23 15 316 A
62 49 05H 0.94 15 Page C-4
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 317 A
62 59 04H 0.95 12 357 A
65 108 03H
-0.91 18 318 A
63 12 01C
-1.02 14 358 A
65 116 VS3 0.94 10 319 A
63 40 DBC
-1.39 7
359 A
65 126 06C
-0.96 16 320 A
63 44 06C
-0.92 12 360 A
65 138 04C
-0.16 25 321 A
63 52 06C 0.81 16 361 A
65 152 VS3 1.14 19 322 A
63 82 03H 0.91 18 362 A
66 13 01C
-1.04 11 323 A
63 104 03C 0.79 15 363 A
66 13 VS4
-0.74 12 324 A
63 106 03H 1.02 12 364 A
66 25 04H 0.92 12 325 A
63 118 03C 0.81 15 365 A
66 27 06C 0.84 15 326 A
63 122 03C 0.79 18 366 A
66 31 04H 0.92 20 327 A
63 124 04C
-0.28 8
367 A
66 31 05H
-0.9 11 328 A
63 124 04C 0.88 15 368 A
66 35 03H 0.91 13 329 A
63 126 04C 0.83 13 369 A
66 35 04H 0.92 15 330 A
63 134 03C 0.71 11 370 A
66 37 06H
-0.09 13 331 A
63 140 DBC 1.26 17 371 A
66 45 05H 0.94 11 332 A
63 142 04C 0.81 11 372 A
66 55 02H 0.9 11 333 A
64 11 VS4
-0.95 28 373 A
66 59 06C 0.91 16 334 A
64 11 VS5 0.76 12 374 A
66 61 04H 0.98 17 335 A
64 13 04H 1.01 17 375 A
66 89 04C
-0.88 14 336 A
64 13 VS4
-0.9 16 376 A
66 107 02C
-1.02 16 337 A
64 25 06C 0.81 10 377 A
66 107 03H 0.14 17 338 A
64 29 DBC 1.57 14 378 A
66 109 02C 0.83 22 339 A
64 37 VS3 0.21 12 379 A
66 109 03H
-0.82 18 340 A
64 37 VS5 0.91 15 380 A
66 109 04C 0.09 18 341 A
64 71 VS5
-0.92 10 381 A
66 109 04C 0.81 18 342 A
64 71 VS5 0.93 10 382 A
66 113 02C 0.76 9
343 A
64 123 04C 0.9 13 383 A
66 113 03H 0.91 13 344 A
64 139 03C 0.85 9
384 A
66 137 06C
-0.94 11 345 A
65 12 01C
-0.28 11 385 A
67 12 03H 0.96 9
346 A
65 12 06H 0.86 21 386 A
67 14 05H 0.9 26 347 A
65 14 06H 0.86 11 387 A
67 20 VS5 0.67 16 348 A
65 16 05H 1.09 14 388 A
67 24 06H 0.26 7
349 A
65 24 VS5
-0.8 13 389 A
67 24 06H 0.92 22 350 A
65 24 VS5 0.67 13 390 A
67 32 06H 1.01 10 351 A
65 32 04H 0.87 8
391 A
67 34 06C 0.96 13 352 A
65 32 DBC
-1.22 7
392 A
67 38 06H
-0.05 6
353 A
65 32 DBC 1.35 8
393 A
67 38 06H 0.91 10 354 A
65 40 03H 0.96 13 394 A
67 56 VS3 0.95 9
355 A
65 90 02C 0.81 16 395 A
67 106 02H 1.09 11 356 A
65 106 04C 0.79 18 396 A
67 106 03H 1
13 Page C-5
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 397 A
67 112 VS3 0.98 12 437 A
69 40 DSH 1.83 14 398 A
67 114 02C 0.9 22 438 A
69 54 03C
-0.97 16 399 A
67 118 03C 0.86 13 439 A
69 60 06H 1
11 400 A
67 120 06H
-0.05 11 440 A
69 86 06C 0.74 19 401 A
67 120 VS5 0.93 16 441 A
69 108 04H 1.03 18 402 A
67 130 DSH 1.69 19 442 A
69 126 DSC 1.53 13 403 A
67 136 VS3 0.74 21 443 A
69 134 06C
-0.98 21 404 A
67 138 03C 0.76 15 444 A
69 136 VS3
-0.73 13 405 A
67 154 01C
-0.6 14 445 A
69 136 VS5 0.78 16 406 A
67 154 02C 0.74 17 446 A
69 152 VS3
-0.75 24 407 A
67 154 04C 0.74 14 447 A
69 152 VS3 1.11 21 408 A
68 15 05H
-0.02 7
448 A
70 15 VS4
-0.91 14 409 A
68 17 VS3
-0.56 13 449 A
70 19 05H 0.9 11 410 A
68 17 VS4
-0.98 5
450 A
70 29 DSC 1.18 7
411 A
68 17 VS4 1.05 9
451 A
70 53 03C 0
21 412 A
68 21 VS3
-0.8 11 452 A
70 55 03C
-0.89 21 413 A
68 21 VS4
-0.89 19 453 A
70 69 05H 0.02 15 414 A
68 21 VS4 0.93 21 454 A
70 81 DSC 1.52 13 415 A
68 21 VS5 0.15 15 455 A
70 85 03H 0.99 15 416 A
68 21 VS5 0.81 13 456 A
70 107 04C
-0.97 22 417 A
68 27 VS3
-0.74 9
457 A
70 107 04H 0.18 11 418 A
68 41 04H 0.92 12 458 A
70 115 DSH 1.87 15 419 A
68 45 06H 1.01 15 459 A
70 129 DSC 1.68 7
420 A
68 53 04H
-0.12 12 460 A
70 137 06H 0.98 14 421 A
68 81 03H 0.96 20 461 A
70 143 DSH 1.86 23 422 A
68 107 03H
-0.05 9
462 A
70 145 DSC
-1.38 12 423 A
68 139 VS3
-0.69 30 463 A
70 153 02C
-0.9 9
424 A
68 139 VS4 0.05 13 464 A
70 153 DSH
-1.58 13 425 A
68 139 VS5
-0.94 13 465 A
70 153 VS3
-0.79 22 426 A
68 139 VS5 0.9 34 466 A
70 153 VS3 0.99 11 427 A
68 141 DSH 1.89 19 467 A
71 34 03H
-0.8 9
428 A
69 22 VS3 0.96 20 468 A
71 54 04H 1.02 15 429 A
69 22 VS4
-0.91 26 469 A
71 78 06C
-0.95 16 430 A
69 22 VS4
-0.02 19 470 A
71 108 02C
-0.21 15 431 A
69 22 VS4 0.98 29 471 A
71 108 05C 0.81 13 432 A
69 22 VS5 0.89 25 472 A
71 110 04H 0.96 12 433 A
69 30 DSC 1.36 12 473 A
71 126 05C 0.09 7
434 A
69 34 06C 0.83 10 474 A
71 126 05C 0.83 17 435 A
69 34 DSH 1.73 14 475 A
71 134 VS3
-0.66 15 436 A
69 40 04H 0.98 12 476 A
71 150 06H 0.87 11 Page C-6
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 477 A
72 29 DBC 1.46 8
517 A
76 15 01C 0
13 478 A
72 53 02C 0.77 13 518 A
76 15 03H
-0.11 10 479 A
72 55 03C
-0.93 15 519 A
76 15 04H
-0.84 11 480 A
72 55 04C
-0.26 12 520 A
76 15 06C 0.76 10 481 A
72 85 05C
-0.09 11 521 A
76 15 DBC
-1.49 32 482 A
72 127 04C 0.81 16 522 A
76 15 DBC 1.41 10 483 A
72 127 VS4 0
13 523 A
76 17 DBC 1.57 15 484 A
72 143 DBC 1.46 19 524 A
76 19 DBC 1.42 9
485 A
72 145 DBH 1.83 16 525 A
76 21 03H 0.84 11 486 A
72 149 DBH 1.77 19 526 A
76 21 04H 0.96 13 487 A
72 151 01H 0
11 527 A
76 37 06H 0
10 488 A
73 14 03H 0.86 9
528 A
76 51 VS3
-0.69 10 489 A
73 14 05H
-0.94 13 529 A
76 51 VS3 1
9 490 A
73 14 VS4
-1.01 16 530 A
76 51 VS4 1.07 13 491 A
73 14 VS4 0.98 13 531 A
76 53 03C 0.79 12 492 A
73 44 06C
-1.05 20 532 A
76 55 03C 0.79 21 493 A
73 66 04C 0.75 17 533 A
76 91 02C 0.79 17 494 A
74 15 01C
-0.95 11 534 A
76 97 04C
-0.97 8
495 A
74 15 VS4 0.84 21 535 A
76 97 04C 0.81 11 496 A
74 19 DBC 1.07 14 536 A
76 101 02H
-0.87 15 497 A
74 33 DBC 1.19 12 537 A
76 101 03H 0.91 12 498 A
74 145 DBC 1.3 17 538 A
76 103 03H
-0.05 12 499 A
74 149 DBC 1.31 16 539 A
76 111 04C 0.79 14 500 A
75 16 03H 0.86 6
540 A
77 16 DBC 1.63 17 501 A
75 16 06C
-0.05 17 541 A
77 16 VS4
-0.83 32 502 A
75 16 VS5
-1 25 542 A
77 18 05H
-0.85 18 503 A
75 20 03H 0.9 13 543 A
77 18 06H
-0.76 14 504 A
75 20 04H
-0.81 11 544 A
77 18 07C
-0.42 9
505 A
75 28 DBH 1.89 15 545 A
77 20 06H
-0.14 11 506 A
75 32 DBH 1.68 16 546 A
77 22 03H 0.91 12 507 A
75 44 VS3
-0.93 39 547 A
77 22 06H 0.96 16 508 A
75 44 VS3 1.14 23 548 A
77 24 03H 0.91 13 509 A
75 50 VS3
-0.84 21 549 A
77 24 04H
-0.07 12 510 A
75 50 VS3 1.03 16 550 A
77 24 06H 1.05 16 511 A
75 58 VS3 1.06 14 551 A
77 28 06H 0.99 10 512 A
75 68 02C 0.85 15 552 A
77 44 VS3 0.99 15 513 A
75 92 06H
-0.75 13 553 A
77 44 VS4 0.08 17 514 A
75 120 03C 0.81 16 554 A
77 44 VS5 0.92 23 515 A
75 148 06C 0.7 9
555 A
77 52 02C 0.74 10 516 A
75 150 02C 0.76 16 556 A
77 52 03C
-0.97 9
Page C-7
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 557 A
77 52 06C
-0.98 9
597 A
80 17 VS4 0.62 8
558 A
77 62 03C 0.86 16 598 A
80 27 VS3 1.06 13 559 A
77 76 VS5 0.99 13 599 A
80 57 04H 0.16 12 560 A
77 102 03H 0.93 15 600 A
80 57 04H 0.98 16 561 A
77 122 06C 0.67 19 601 A
80 77 02H
-0.89 10 562 A
77 124 03C
-0.92 10 602 A
80 77 04H 0.94 18 563 A
77 124 03C 0.88 15 603 A
80 107 DSH 1.83 24 564 A
77 132 07C 0.96 18 604 A
80 119 03C 0.79 9
565 A
77 144 04C 0.83 15 605 A
80 143 05C 0.87 11 566 A
77 148 03C 0.77 24 606 A
80 145 02C
-0.23 10 567 A
77 148 07H
-1.09 15 607 A
80 147 07H 0.86 14 568 A
77 150 02C 0.81 16 608 A
80 149 VS4
-0.81 17 569 A
78 17 DSH
-1.33 21 609 A
81 18 01H 0.98 12 570 A
78 19 DSC
-2.01 14 610 A
81 18 DSC
-1.63 10 571 A
78 25 05C
-0.95 14 611 A
81 18 VS4
-0.68 14 572 A
78 25 DSC
-1.99 13 612 A
81 20 04H
-0.16 10 573 A
78 113 02C 0.72 16 613 A
81 20 04H 1.06 11 574 A
78 147 02C
-0.23 16 614 A
81 24 DSC
-1.44 13 575 A
78 149 DSC
-1.69 14 615 A
81 46 VS3 0
17 576 A
79 16 DSH
-1.3 9
616 A
81 46 VS3 0.86 18 577 A
79 18 DSC 1.2 9
617 A
81 46 VS5 0.86 21 578 A
79 18 VS4
-0.84 15 618 A
81 54 05C
-1.02 15 579 A
79 18 VS4 1.05 8
619 A
81 84 07C
-0.11 20 580 A
79 20 05H 0.99 11 620 A
81 84 VS4 1.06 29 581 A
79 22 07C 1.16 10 621 A
81 94 02C
-0.99 14 582 A
79 68 07H 1.07 13 622 A
81 94 02C
-0.23 10 583 A
79 72 04H 0.94 16 623 A
81 94 DSH 1.88 14 584 A
79 72 VS3 0.12 18 624 A
81 102 07C
-0.79 15 585 A
79 82 03H 0.91 18 625 A
81 118 VS3
-0.78 11 586 A
79 90 04C
-0.26 19 626 A
81 130 VS3
-0.76 18 587 A
79 94 03C
-1.04 9
627 A
81 130 VS3
-0.13 17 588 A
79 104 05H 0.98 13 628 A
81 148 02C 0.81 21 589 A
79 116 03C
-0.95 11 629 A
81 148 05C 0.05 23 590 A
79 128 04C 0.81 20 630 A
82 19 DSC
-1.07 14 591 A
79 144 VS5
-0.75 12 631 A
82 19 VS4
-0.92 6
592 A
79 144 VS5 0.9 22 632 A
82 19 VS4 0.71 14 593 A
79 148 02C 0.79 10 633 A
82 33 VS3 1.01 13 594 A
79 150 02C 0.02 15 634 A
82 61 VS3
-0.75 15 595 A
79 150 02C 0.84 13 635 A
82 71 VS3 0.99 11 596 A
79 150 VS4 1.05 20 636 A
82 89 05C 0.76 17 Page C-8
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 637 A
82 121 05H 1.03 10 677 A
84 99 VS2
-0.75 17 638 A
82 135 VS3
-0.82 14 678 A
84 125 04C
-1.04 11 639 A
82 141 VS3
-0.84 23 679 A
84 141 04C 0.82 19 640 A
83 76 02H 0.93 14 680 A
84 143 03C 0.79 9
641 A
83 84 02C 0.83 14 681 A
84 147 VS3 0.94 20 642 A
83 100 04H 0.91 22 682 A
84 147 VS5 0.75 9
643 A
83 102 05C
-0.19 15 683 A
85 20 VS4
-0.93 26 644 A
83 114 VS2
-0.77 8
684 A
85 20 VS4 0.84 22 645 A
83 116 VS2
-0.2 13 685 A
85 26 03H 0.86 17 646 A
83 122 VS2 0.77 13 686 A
85 28 VS3
-0.73 10 647 A
83 130 VS2 0.81 9
687 A
85 30 VS3
-0.77 14 648 A
83 136 DBH 1.67 12 688 A
85 62 04C 0.39 18 649 A
83 146 04C
-0.86 14 689 A
85 84 05H 1
14 650 A
83 148 03C
-0.97 16 690 A
85 92 02C 0.74 16 651 A
83 148 07C 0.95 9
691 A
85 104 03C 0.76 17 652 A
83 148 VS4
-0.78 14 692 A
85 146 02C 0.77 17 653 A
83 148 VS4
-1.16 14 693 A
85 146 03C
-0.98 26 654 A
84 19 01H
-0.82 12 694 A
86 21 VS4
-0.83 13 655 A
84 19 01H
-0.05 12 695 A
86 35 VS6
-0.74 16 656 A
84 19 VS2 0.59 14 696 A
86 55 06C 0.83 15 657 A
84 19 VS3 0.28 10 697 A
86 97 03H 0.93 19 658 A
84 19 VS4
-1.19 21 698 A
86 101 04H
-0.84 15 659 A
84 19 VS4 0.96 20 699 A
86 111 05C 0.79 14 660 A
84 19 VS5 0.96 17 700 A
86 143 03C
-0.93 17 661 A
84 25 VS2 0.68 10 701 A
86 145 02C 0.76 11 662 A
84 29 VS2 0.76 16 702 A
86 145 03C
-0.9 12 663 A
84 33 VS2
-0.75 19 703 A
86 145 03C 0.78 7
664 A
84 37 VS2
-0.79 15 704 A
86 145 04C 0.77 17 665 A
84 39 VS3
-0.93 18 705 A
87 20 VS4
-0.83 11 666 A
84 41 07H 0.89 11 706 A
87 20 VS4
-0.26 15 667 A
84 45 VS6
-0.77 11 707 A
87 20 VS4 0.6 24 668 A
84 47 06H 1.05 11 708 A
87 22 01H 0.96 10 669 A
84 51 DBH 1.65 12 709 A
87 22 04H 0.9 10 670 A
84 51 VS2 0.67 11 710 A
87 22 VS4
-0.99 15 671 A
84 53 VS2
-0.75 23 711 A
87 36 DBH 1.88 16 672 A
84 61 03C 0.8 27 712 A
87 40 07C 0.72 18 673 A
84 73 05C 0.84 13 713 A
87 40 07H
-0.71 15 674 A
84 85 04H 0.93 16 714 A
87 40 VS2
-0.73 9
675 A
84 93 05C
-0.98 10 715 A
87 58 VS2
-0.78 13 676 A
84 93 05C
-0.23 9
716 A
87 60 VS2
-0.7 14 Page C-9
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 717 A
87 82 05H 0.91 14 757 A
88 145 VS4 0.81 22 718 A
87 88 04H 0.27 9
758 A
89 26 VS6 0.91 15 719 A
87 90 04H
-0.11 7
759 A
89 28 VS6 0.96 6
720 A
87 90 04H 0.95 10 760 A
89 32 03C
-0.99 14 721 A
87 92 04C 0.72 17 761 A
89 34 04H
-0.89 13 722 A
87 92 04H
-0.77 11 762 A
89 42 07H 0.91 12 723 A
87 92 04H 0.95 7
763 A
89 70 06C 0.81 15 724 A
87 92 05C 0.79 13 764 A
89 72 01C 0.76 15 725 A
87 100 04H 1.02 16 765 A
89 78 07H
-0.75 10 726 A
87 102 05H 0.91 18 766 A
89 78 07H 1.04 18 727 A
87 106 06H 0.41 12 767 A
89 84 04H
-0.8 11 728 A
87 110 03H 0.84 11 768 A
89 108 04H 0.93 17 729 A
87 112 04H 0.91 11 769 A
89 108 05H 0.95 20 730 A
87 116 03C
-0.16 12 770 A
89 108 06H 0.95 29 731 A
87 116 04C 0.79 17 771 A
89 112 05H
-0.75 12 732 A
87 120 VS2 0.28 12 772 A
89 112 05H 0.2 14 733 A
87 120 VS2 0.83 16 773 A
89 112 05H 0.93 13 734 A
87 124 04C
-1.07 12 774 A
89 128 03H 0.84 14 735 A
87 142 03C
-1.04 8
775 A
89 136 03H 0.92 17 736 A
87 144 03C
-0.92 16 776 A
90 23 VS4
-0.87 14 737 A
87 144 04C 0.79 12 777 A
90 25 VS4 0.96 12 738 A
87 146 02C 0.79 11 778 A
90 31 04H 0.89 10 739 A
87 146 VS4
-0.99 15 779 A
90 35 05H 0.99 8
740 A
87 146 VS4 0.56 21 780 A
90 59 01H
-0.68 15 741 A
88 21 VS4
-0.88 25 781 A
90 59 04H
-0.21 10 742 A
88 21 VS4 0.25 10 782 A
90 59 04H 0.87 11 743 A
88 53 07C 0.85 20 783 A
90 87 02C 0.83 14 744 A
88 53 VS4 0.99 16 784 A
90 87 03H 0.9 19 745 A
88 57 06H 0.97 13 785 A
90 87 04C 0.35 11 746 A
88 57 07C 0.85 22 786 A
90 87 06H 0.63 15 747 A
88 57 VS6 0.98 11 787 A
90 93 03C 0.76 22 748 A
88 59 05C 0.02 15 788 A
90 93 04C 0.77 14 749 A
88 59 05C 0.74 19 789 A
90 95 04C 0.74 19 750 A
88 61 02C 0.84 20 790 A
90 95 06C 0.76 17 751 A
88 61 03C 0.42 21 791 A
90 95 07C 0.07 13 752 A
88 73 02H
-0.07 18 792 A
90 101 02C 0
14 753 A
88 91 04H 1
13 793 A
90 105 05C 0.86 19 754 A
88 99 06H
-0.81 11 794 A
90 107 04H 0.93 18 755 A
88 145 02C 0.05 27 795 A
90 107 05C 0.79 16 756 A
88 145 04C
-1.02 22 796 A
90 115 VS2
-0.67 14 Page C-10
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 797 A
90 115 VS6
-0.71 15 837 A
92 133 05C
-0.76 12 798 A
90 135 04C 0.79 14 838 A
92 133 07H 0.89 13 799 A
90 135 04H 0.91 11 839 A
92 135 04C 0.77 18 800 A
90 137 06C 0.82 13 840 A
92 137 04C 0.74 12 801 A
90 143 02C
-0.93 28 841 A
92 141 02C
-0.3 13 802 A
90 143 02C 0.21 21 842 A
92 141 04C 0.79 11 803 A
90 143 03C
-0.93 18 843 A
93 26 DBC 0.74 6
804 A
91 22 VS4 0.53 33 844 A
93 26 VS4
-0.84 15 805 A
91 22 VS6
-0.81 8
845 A
93 26 VS4 0.94 12 806 A
91 26 03H 0.91 8
846 A
93 60 VS2
-0.66 19 807 A
91 66 05C 0.75 15 847 A
93 60 VS2 1.07 22 808 A
91 70 VS6 1.14 14 848 A
93 60 VS6
-0.98 17 809 A
91 90 03C 0.76 17 849 A
93 60 VS6 1.11 13 810 A
91 90 05H 0.98 7
850 A
93 76 VS4 0.09 17 811 A
91 114 VS2
-0.76 12 851 A
93 76 VS4 0.87 18 812 A
91 116 VS2
-0.74 27 852 A
93 94 04C 0.77 13 813 A
91 144 03C
-0.95 10 853 A
93 100 VS2
-0.68 12 814 A
91 144 VS4 0.74 14 854 A
93 104 DBH 1.91 14 815 A
92 23 VS2 0.65 21 855 A
93 104 VS4
-0.6 33 816 A
92 23 VS2 1
16 856 A
93 104 VS6
-0.9 11 817 A
92 23 VS6 0.61 7
857 A
93 104 VS6 1.02 26 818 A
92 23 VS6 1.02 24 858 A
93 106 VS2
-0.63 20 819 A
92 25 VS4
-0.85 8
859 A
93 130 03H
-0.78 13 820 A
92 25 VS4 0.88 12 860 A
93 130 04H
-0.82 8
821 A
92 29 03H 0.93 12 861 A
93 130 VS2
-0.62 21 822 A
92 35 06H 1.07 14 862 A
93 130 VS2 1.04 13 823 A
92 37 04H 0.92 8
863 A
93 130 VS4
-0.85 16 824 A
92 59 VS4
-0.89 15 864 A
93 130 VS4 1.01 36 825 A
92 59 VS4 0.14 10 865 A
93 136 03C
-0.97 20 826 A
92 59 VS4 0.86 17 866 A
93 136 03C 0.81 16 827 A
92 59 VS6 1.09 14 867 A
93 138 osc 0.77 13 828 A
92 69 05C 0.05 13 868 A
94 25 03H
-0.84 10 829 A
92 85 VS6 1.01 17 869 A
94 25 VS4
-0.95 15 830 A
92 89 04C 0.79 18 870 A
94 25 VS4
-0.12 8
831 A
92 101 VS2
-0.76 15 871 A
94 27 03H 0.88 14 832 A
92 101 VS2 0.9 16 872 A
94 31 VS4
-1 23 833 A
92 117 VS4
-0.62 10 873 A
94 51 04C 0.79 15 834 A
92 117 VS4 0.89 10 874 A
94 61 04H 1.02 13 835 A
92 125 03H 0.93 10 875 A
94 67 VS6
-0.89 19 836 A
92 133 04C 0.83 15 876 A
94 67 VS6 0.85 10 Page C-11
e Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 877 A
94 69 05H
-0.71 11 917 A
96 27 VS4 1.09 10 878 A
94 77 VS2
-0.71 15 918 A
96 31 VS4 0.91 9
879 A
94 77 VS2 1.15 29 919 A
96 31 VS6
-0.7 13 880 A
94 77 VS6
-0.87 10 920 A
96 33 VS4
-0.89 9
881 A
94 93 06C 0.84 16 921 A
96 37 VS6
-0.8 13 882 A
94 95 07C
-0.95 19 922 A
96 39 VS6 0.07 14 883 A
94 101 04C
-1 22 923 A
96 41 VS6
-0.26 10 884 A
94 135 04C 0.79 11 924 A
96 41 VS6 1.08 14 885 A
94 139 03C
-0.88 17 925 A
96 55 06C
-0.97 9
886 A
94 141 03C 0.79 18 926 A
96 59 04C
-0.95 19 887 A
95 24 VS4
-1.06 27 927 A
96 61 04H 0.18 10 888 A
95 24 VS4 0.23 19 928 A
96 61 06C 0.05 19 889 A
95 26 VS4 0.9 9
929 A
96 61 06H 0.96 15 890 A
95 30 VS4
-0.9 38 930 A
96 63 04C 0.72 24 891 A
95 30 VS4 0.92 31 931 A
96 65 05H
-0.89 10 892 A
95 30 VS6 0
14 932 A
96 87 05C 0.81 20 893 A
95 32 04H
-0.21 10 933 A
96 87 05H 0.98 15 894 A
95 48 06C 0.82 20 934 A
96 103 05C 0.79 13 895 A
95 58 04H 1.03 10 935 A
96 105 07H 1.03 11 896 A
95 58 VS2
-0.71 9
936 A
96 105 VS6
-0.78 15 897 A
95 60 06H 0.96 11 937 A
96 109 04C 0.86 14 898 A
95 72 07C 0.83 12 938 A
96 111 04C 0.72 16 899 A
95 84 05C 0.74 18 939 A
96 111 05C 0.74 16 900 A
95 118 VS2 0.18 13 940 A
96 117 VS6
-0.8 12 901 A
95 124 VS2
-0.69 16 941 A
96 121 VS6 1.02 16 902 A
95 124 VS2 1.1 18 942 A
96 131 04C
-0.97 21 903 A
95 126 VS2 1.17 15 943 A
96 141 VS4
-0.97 14 904 A
95 130 04H 0.91 10 944 A
96 141 VS4 0.97 12 905 A
95 130 VS2 0.23 9
945 A
97 26 VS4
-0.83 16 906 A
95 130 VS2 1.06 18 946 A
97 26 VS4 0.56 19 907 A
95 132 VS2 1.02 21 947 A
97 28 VS4
-0.64 7
908 A
95 132 VS4 1.04 14 948 A
97 28 VS4 0.9 12 909 A
95 134 04C
-1 24 949 A
97 46 VS4 0.91 9
910 A
95 136 VS2
-0.78 15 950 A
97 46 VS6
-0.72 13 911 A
95 136 VS2 0.98 22 951 A
97 46 VS6
-0.12 13 912 A
95 140 04C 0.72 19 952 A
97 48 DSC 1.55 9
913 A
95 142 02C 0.02 14 953 A
97 48 VS4
-0.89 14 914 A
95 142 02C 0.76 11 954 A
97 48 VS4 0.96 15 915 A
96 25 02H 0.89 16 955 A
97 48 VS6
-0.84 15 916 A
96 25 VS4 0.83 35 956 A
97 48 VS6 1.03 15 Page C-12
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 957 A
97 50 VS2
-0.76 31 997 A
98 27 VS6
-0.77 9
958 A
97 50 VS2 0.94 15 998 A
98 27 VS6 0.88 16 959 A
97 50 VS4
-0.71 21 999 A
98 35 05H 0.92 12 960 A
97 50 VS4 0.99 19 1000 A
98 39 05H 1.01 13 961 A
97 50 VS6 0.81 21 1001 A
98 55 05H 1.02 15 962 A
97 52 VS2 0.9 22 1002 A
98 55 DBC
-1.66 14 963 A
97 52 VS4
-0.66 31 1003 A
98 59 05C
-1.02 18 964 A
97 52 VS6 0.82 26 1004 A
98 63 05C
-0.86 13 965 A
97 54 05C
-0.23 14 1005 A
98 65 VS2
-0.53 25 966 A
97 58 07C 0.76 18 1006 A
98 75 06C 0.79 18 967 A
97 62 05C
-1.04 17 1007 A
98 85 06C 0.77 16 968 A
97 62 06C 0.79 18 1008 A
98 85 DBC 1.7 11 969 A
97 64 06C
-0.91 18 1009 A
98 85 VS6
-0.83 12 970 A
97 90 05C 0.74 16 1010 A
98 87 06C 0.79 26 971 A
97 90 VS6
-0.66 24 1011 A
98 105 04C 0.81 24 972 A
97 96 04C
-1 11 1012 A
98 105 05C
-1.02 21 973 A
97 96 VS2 0.16 14 1013 A
98 109 05C 0.79 22 974 A
97 96 VS2 0.74 14 1014 A
98 109 05H
-0.75 15 975 A
97 100 VS2 0.18 15 1015 A
98 111 VS2
-0.11 10 976 A
97 106 VS4
-0.84 25 1016 A
98 111 VS2 0.71 16 977 A
97 106 VS4 0.92 16 1017 A
98 113 VS2 0.62 13 978 A
97 112 VS4
-0.85 11 1018 A
98 119 VS6 0.78 15 979 A
97 114 VS4
-0.92 9
1019 A
98 127 07H 0.93 15 980 A
97 116 05C 0.49 20 1020 A
98 133 04C 0.76 14 981 A
97 116 VS4
-0.8 13 1021 A
98 139 02C
-0.23 17 982 A
97 118 VS4 0.78 26 1022 A
99 26 VS4
-0.85 17 983 A
97 120 VS2
-0.82 12 1023 A
99 26 VS4
-0.43 18 984 A
97 120 VS2 1.08 26 1024 A
99 28 VS4
-0.54 11 985 A
97 120 VS4 0.69 13 1025 A
99 28 VS4 0.98 14 986 A
97 124 VS2
-0.77 9
1026 A
99 30 VS4
-0.83 13 987 A
97 124 VS2 1.03 10 1027 A
99 30 VS4 0.79 12 988 A
97 126 VS4
-0.05 15 1028 A
99 36 VS4 0.91 12 989 A
97 132 04C
-0.97 13 1029 A
99 84 VS6
-0.85 18 990 A
97 132 DBH 1.88 10 1030 A
99 84 VS6 0.98 12 991 A
97 132 VS4 0.87 14 1031 A
99 104 02C
-1.03 17 992 A
97 134 VS4 0.95 21 1032 A
99 104 02C 0.12 12 993 A
97 136 04C
-1 12 1033 A
99 112 04C 0.74 16 994 A
97 138 02C 0.76 13 1034 A
99 116 VS4
-0.9 8
995 A
97 140 03C
-0.95 16 1035 A
99 136 VS4
-0.91 13 996 A
98 27 VS2 0.57 19 1036 A
99 136 VS4 0.52 8
Page C-13
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1037 A
99 138 02C
-1.09 19 1077 A
100 119 VS6 1.05 15 1038 A
99 138 02C 0
16 1078 A
100 131 05C 0.79 9
1039 A
99 138 03C
-0.4 19 1079 A
100 137 03C
-0.56 36 1040 A
99 138 03H 0.87 14 1080 A
100 137 05C
-0.93 17 1041 A
99 138 VS4 0.09 19 1081 A
100 139 03C
-0.16 14 1042 A
99 138 VS4 0.79 19 1082 A
100 139 VS4
-0.79 18 1043 A
99 140 03C
-0.99 16 1083 A
101 28 03H 0.95 10 1044 A
99 140 03C
-0.23 17 1084 A
101 28 VS4
-0.82 17 1045 A
99 140 VS4
-0.74 24 1085 A
101 28 VS4 0.6 16 1046 A
100 27 VS4
-0.8 27 1086 A
101 30 04H
-0.09 18 1047 A
100 27 VS4
-0.12 13 1087 A
101 30 VS4
-0.92 14 1048 A
100 27 VS4 1.1 13 1088 A
101 30 VS4 0.6 8
1049 A
100 29 04H 0.84 14 1089 A
101 36 03H 0.95 9
1050 A
100 29 05H 0.94 15 1090 A
101 48 DBC 1.6 12 1051 A
100 29 06H 0.93 17 1091 A
101 56 06C
-0.98 11 1052 A
100 29 VS2
-0.86 13 1092 A
101 70 05H 0.99 14 1053 A
100 29 VS2 0.99 20 1093 A
101 110 VS2 0.23 12 1054 A
100 29 VS4 0.18 9
1094 A
101 110 VS2 0.87 13 1055 A
100 29 VS4 0.97 14 1095 A
101 118 DBH 1.87 15 1056 A
100 31 04H 0.87 9
1096 A
101 124 07C 0.69 12 1057 A
100 31 06H
-0.85 9
1097 A
101 128 04H
-0.82 10 1058 A
100 31 06H 0
13 1098 A
101 136 02C 0.07 12 1059 A
100 31 VS2
-0.86 11 1099 A
101 136 03C
-1 10 1060 A
100 33 03H 0.89 10 1100 A
101 138 07C 0.8 9
1061 A
100 33 VS2
-0.88 9
1101 A
101 138 VS4 0.72 19 1062 A
100 35 03H
-0.75 14 1102 A
102 29 04C
-1.02 16 1063 A
100 49 05C 0.79 14 1103 A
102 29 VS4
-0.9 24 1064 A
100 61 03H
-0.84 9
1104 A
102 29 VS4
-0.09 11 1065 A
100 67 VS6
-0.84 29 1105 A
102 67 07H 1.02 14 1066 A
100 89 VS2
-0.68 18 1106 A
102 73 07C
-0.9 17 1067 A
100 103 02C 0.76 21 1107 A
102 75 VS2
-0.67 15 1068 A
100 103 05C
-0.96 17 1108 A
102 89 04C 0.76 20 1069 A
100 107 04C 0.74 12 1109 A
102 95 05C
-0.21 15 1070 A
100 107 VS4
-0.86 16 1110 A
102 105 03C
-1.04 11 1071 A
100 113 DBH 1.88 13 1111 A
102 105 05C 0.75 16 1072 A
100 115 05H
-0.86 12 1112 A
102 115 VS2
-0.64 13 1073 A
100 119 VS2
-0.63 21 1113 A
102 115 VS2 0.16 18 1074 A
100 119 VS2 0.16 25 1114 A
102 117 03H 0.86 20 1075 A
100 119 VS2 0.81 10 1115 A
102 121 VS4
-0.88 20 1076 A
100 119 VS4
-0.74 14 1116 A
102 135 03C
-0.3 17 Page C-14
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1117 A
102 135 04C 0.78 13 1157 A
104 123 04C 0.79 14 1118 A
102 137 04C
-1.02 14 1158 A
104 135 03C 0.84 28 1119 A
103 30 05H
-0.87 16 1159 A
105 30 VS4
-0.65 25 1120 A
103 30 07H
-0.89 14 1160 A
105 32 01C 0
15 1121 A
103 30 VS4
-0.07 12 1161 A
105 32 04H
-0.89 12 1122 A
103 30 VS4 0.7 19 1162 A
105 90 osc 0.79 17 1123 A
103 32 02C
-0.21 11 1163 A
105 112 05H 1.05 15 1124 A
103 32 03C 0.02 8
1164 A
105 132 03C 0.79 17 1125 A
103 32 VS4
-0.98 16 1165 A
105 136 VS4
-0.72 17 1126 A
103 32 VS4 0.56 9
1166 A
105 136 VS4 1
15 1127 A
103 36 DSC
-1.02 11 1167 A
106 31 01C
-1.02 12 1128 A
103 36 VS2
-0.81 9
1168 A
106 31 03C 0.8 11 1129 A
103 36 VS2 0.98 10 1169 A
106 31 04C 0.75 19 1130 A
103 38 05H 0.23 14 1170 A
106 31 VS2 0.05 12 1131 A
103 54 05H 0.99 12 1171 A
106 31 VS4 0.98 14 1132 A
103 82 05H
-0.05 18 1172 A
106 31 VS6
-0.85 32 1133 A
103 82 06H 1.01 15 1173 A
106 31 VS6 0.35 18 1134 A
103 86 VS2 0.25 15 1174 A
106 31 VS6 0.94 27 1135 A
103 86 VS2 0.68 16 1175 A
106 33 04C
-1 11 1136 A
103 96 osc 0.81 15 1176 A
106 33 VS4
-0.74 18 1137 A
103 108 07C
-0.23 12 1177 A
106 35 03C
-0.14 18 1138 A
103 122 DBC 1.69 20 1178 A
106 35 03C 0.67 21 1139 A
103 134 04C 0.02 12 1179 A
106 45 05H
-0.07 10 1140 A
103 134 04C 0.83 12 1180 A
106 47 04C
-0.02 12 1141 A
103 136 DBH
-1.54 14 1181 A
106 47 04C 0.77 13 1142 A
104 31 VS4
-0.9 21 1182 A
106 57 07H 0.99 22 1143 A
104 31 VS4 0.92 19 1183 A
106 59 VS2
-0.79 13 1144 A
104 33 03C
-1.02 12 1184 A
106 59 VS4
-1.04 27 1145 A
104 33 04C
-1 9
1185 A
106 59 VS4 0.98 38 1146 A
104 61 06C 0.79 14 1186 A
106 59 VS6
-0.81 24 1147 A
104 71 DBH 1.86 21 1187 A
106 63 VS4
-1.05 15 1148 A
104 85 VS2
-0.63 12 1188 A
106 63 VS4 0.3 17 1149 A
104 87 04C
-0.97 24 1189 A
106 67 VS6 0.36 19 1150 A
104 95 VS2
-0.59 21 1190 A
106 69 VS2 0.84 13 1151 A
104 97 03C
-0.3 8
1191 A
106 69 VS4
-1.16 16 1152 A
104 97 03C 0.72 11 1192 A
106 69 VS6 0.9 12 1153 A
104 97 04C
-0.97 22 1193 A
106 107 05C
-0.93 17 1154 A
104 99 06C 0.76 15 1194 A
106 117 06C
-1.05 16 1155 A
104 103 DSC 0.81 12 1195 A
106 117 VS2 0
12 1156 A
104 109 VS6
-0.61 15 1196 A
106 119 VS4
-1.11 11 Page C-15
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1197 A
106 119 VS4 1.07 12 1237 A
108 41 VS4 0.97 16 1198 A
106 121 04C 0
9 1238 A
108 63 VS2 0.07 15 1199 A
106 121 04C 0.77 17 1239 A
108 63 VS2 0.88 16 1200 A
106 121 05C 0.42 17 1240 A
108 95 03C 0.76 14 1201 A
106 131 03C
-0.53 15 1241 A
108 99 DBH 1.97 15 1202 A
106 133 03C 0.83 14 1242 A
108 115 05H 1.02 11 1203 A
106 133 DBC 1.62 22 1243 A
108 123 VS2
-0.71 16 1204 A
106 135 01H 0.07 9
1244 A
108 133 04C
-0.92 13 1205 A
106 135 VS4
-0.75 22 1245 A
108 133 04C 0.71 11 1206 A
107 32 03C 0.83 14 1246 A
109 34 01C 0.76 7
1207 A
107 32 04C
-1.09 7
1247 A
109 34 01H 1.03 10 1208 A
107 32 04C
-0.28 14 1248 A
109 34 04H
-0.84 12 1209 A
107 32 VS4
-0.78 33 1249 A
109 34 05H
-0.75 14 1210 A
107 32 VS4
-0.26 12 1250 A
109 34 VS4
-0.84 11 1211 A
107 34 VS4 0.92 10 1251 A
109 34 VS4 0.67 32 1212 A
107 36 03C 0.7 9
1252 A
109 98 VS2
-0.79 30 1213 A
107 40 VS2
-0.83 11 1253 A
109 114 06C 0.7 15 1214 A
107 44 05H
-0.87 14 1254 A
109 118 04C
-0.97 15 1215 A
107 44 05H
-0.14 16 1255 A
109 120 03C
-0.21 16 1216 A
107 44 VS2 0.8 15 1256 A
109 132 04C 0.76 16 1217 A
107 44 VS4 0.98 10 1257 A
110 35 01H 0.9 14 1218 A
107 120 DBH 2.07 19 1258 A
110 35 VS4 0.94 11 1219 A
107 124 VS2
-0.76 9
1259 A
110 39 VS2 0.94 15 1220 A
107 124 VS2
-0.07 15 1260 A
110 115 08H 0.92 9
1221 A
107 124 VS2 0.72 9
1261 A
110 123 08H
-0.81 29 1222 A
107 128 04C
-1.09 14 1262 A
110 131 01H 0.18 18 1223 A
107 130 03C
-0.88 11 1263 A
110 131 03C 0.76 15 1224 A
107 130 VS2
-0.78 20 1264 A
110 131 DBH
-1.71 34 1225 A
107 130 VS2 0.68 8
1265 A
111 44 06C
-0.21 17 1226 A
107 134 02C
-1.02 22 1266 A
111 62 VS2
-0.66 19 1227 A
107 134 03H 0.87 13 1267 A
111 110 VS4
-0.94 13 1228 A
107 134 VS4
-0.93 18 1268 A
111 116 03H 0.96 11 1229 A
107 134 VS4 0.84 14 1269 A
111 126 04C 0.65 13 1230 A
108 33 VS4
-0.87 32 1270 A
111 128 03C
-0.98 18 1231 A
108 33 VS4 0.99 24 1271 A
111 128 03C 0.81 10 1232 A
108 35 01C 0
27 1272 A
111 128 VS4 0.96 11 1233 A
108 35 01C 0.79 19 1273 A
111 130 04C
-0.26 21 1234 A
108 35 VS4
-0.96 12 1274 A
112 37 02C
-0.97 19 1235 A
108 35 VS4 0.97 9
1275 A
112 37 DBH
-1.55 17 1236 A
108 39 04H 0.8 12 1276 A
112 39 VS6 0.89 12 Page C-16
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1277 A
112 41 VS4
-0.89 20 1317 A
115 46 VS4
-0.85 14 1278 A
112 41 VS6
-0.81 12 1318 A
115 50 VS4
-0.75 13 1279 A
112 59 VS4
-0.75 19 1319 A
115 78 06H
-0.73 19 1280 A
112 59 VS4 0.02 22 1320 A
115 90 VS2
-0.9 12 1281 A
112 59 VS6 1
31 1321 A
115 90 VS4
-0.88 35 1282 A
112 65 VS4
-0.74 12 1322 A
115 92 VS1 0.86 28 1283 A
112 65 VS4 0.72 13 1323 A
115 124 04C
-1.09 13 1284 A
112 89 VS4
-0.85 14 1324 A
115 128 05H 0.89 11 1285 A
112 103 04H 0.96 14 1325 A
116 39 01C
-0.19 11 1286 A
112 125 04C 0.76 10 1326 A
116 39 02C
-1 32 1287 A
112 125 DSC
-0.93 11 1327 A
116 39 VS6
-0.59 14 1288 A
112 127 DSC
-1.11 17 1328 A
116 45 02H 0.89 12 1289 A
112 129 04C 0.79 11 1329 A
116 45 VS7 0.79 12 1290 A
113 36 01H
-0.07 10 1330 A
116 51 07H 0.92 14 1291 A
113 36 01H 0.94 12 1331 A
116 61 VS4 1.06 11 1292 A
113 36 VS4
-0.5 16 1332 A
116 71 VS4 1.02 10 1293 A
113 38 01C
-1.06 11 1333 A
116 81 VS6
-0.75 14 1294 A
113 38 02C 0.79 13 1334 A
116 95 06C 0.76 11 1295 A
113 42 VS4
-0.88 14 1335 A
116 95 07C
-0.94 17 1296 A
113 42 VS4 1.01 15 1336 A
116 105 VS4
-1.02 24 1297 A
113 66 01H
-0.21 20 1337 A
116 111 osc
-0.12 13 1298 A
113 68 VS2
-0.59 18 1338 A
116 119 03C 0.74 19 1299 A
113 68 VS4
-0.86 12 1339 A
116 121 04C 0.81 22 1300 A
113 68 VS6 1.08 16 1340 A
116 121 VS7 1.04 15 1301 A
113 76 VS6 0.95 16 1341 A
116 123 06C
-0.14 13 1302 A
113 90 VS4
-0.57 11 1342 A
117 40 02C
-0.25 9
1303 A
113 98 05H 0.8 14 1343 A
117 40 02C 0.81 25 1304 A
113 118 04C 0.05 13 1344 A
117 40 VS4
-0.78 21 1305 A
113 128 03H 0.89 11 1345 A
117 42 01C
-0.96 35 1306 A
113 128 04H
-0.89 15 1346 A
117 58 06C 0.77 15 1307 A
113 130 VS4
-0.77 19 1347 A
117 90 VS2 0.92 10 1308 A
113 130 VS4
-0.4 22 1348 A
117 120 03H 0.82 12 1309 A
114 123 03C
-1.04 19 1349 A
117 122 VS4 0.05 14 1310 A
114 129 08H
-0.81 15 1350 A
118 41 01H 0.99 11 1311 A
114 129 VS4
-0.91 22 1351 A
118 41 02C 0
26 1312 A
114 129 VS4 0.97 12 1352 A
118 41 VS4
-0.87 20 1313 A
115 38 02C
-0.97 14 1353 A
118 43 01C
-0.98 34 1314 A
115 38 02C 0
15 1354 A
118 43 06H
-0.85 10 1315 A
115 38 VS4 0.46 12 1355 A
118 47 02H 0.87 12 1316 A
115 38 VS4 0.87 11 1356 A
118 51 06C 0.79 16 Page C-17
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1357 A
118 53 VS6
-0.72 12 1397 A
121 118 VS4
-0.07 17 1358 A
118 63 VS4
-0.91 16 1398 A
121 118 VS4 0.81 16 1359 A
118 63 VS4 0.88 12 1399 A
121 120 06H 0.93 12 1360 A
118 97 VS2
-0.99 11 1400 A
122 53 06H 0.95 13 1361 A
118 99 VS2 0.83 17 1401 A
122 63 05H 0.14 15 1362 A
118 101 04H
-0.09 12 1402 A
122 81 VS4 1.12 20 1363 A
118 101 VS4 0.91 14 1403 A
122 111 05C
-0.88 16 1364 A
118 105 04C 0.77 17 1404 A
122 117 VS1 0.86 12 1365 A
118 125 VS?
-0.75 16 1405 A
122 117 VS2
-0.75 12 1366 A
119 42 VS4
-0.89 13 1406 A
122 117 VS2 0.29 9
1367 A
119 44 02H 0.93 10 1407 A
123 102 VS4 0.98 12 1368 A
119 52 06C 0.77 23 1408 A
123 110 VS2 0.88 11 1369 A
119 60 VS4
-0.87 12 1409 A
123 120 02H 0.88 11 1370 A
119 60 VS4 0.92 13 1410 A
123 120 VS4
-0.75 12 1371 A
119 82 VS4 0.14 14 1411 A
124 49 01H 0.94 11 1372 A
119 110 04C
-1 17 1412 A
124 51 03H 0.89 13 1373 A
119 110 VS1 0.64 11 1413 A
124 117 03C 0
12 1374 A
119 122 06H 0.89 14 1414 A
124 119 VS4
-0.87 10 1375 A
119 124 VS4
-0.74 12 1415 A
125 48 VS4
-0.85 20 1376 A
120 81 07C 0
18 1416 A
125 110 03C 0.74 19 1377 A
120 81 07C 0.76 18 1417 A
125 112 03C
-0.02 15 1378 A
120 81 VS4 0.98 12 1418 A
125 112 04C
-1 13 1379 A
120 89 06C
-0.97 17 1419 A
125 112 07H
-0.14 17 1380 A
120 93 06C 0.81 17 1420 A
125 112 VS6
-0.83 13 1381 A
120 111 03C
-1.11 10 1421 A
126 51 01H 0.09 10 1382 A
120 111 04C 0
14 1422 A
126 51 03H 0.89 18 1383 A
120 115 05C
-1.07 15 1423 A
126 63 07H 0.91 8
1384 A
120 119 03C 0.81 21 1424 A
126 69 VS4
-0.85 16 1385 A
120 121 05C 0.79 21 1425 A
126 69 VS4 0.89 35 1386 A
120 123 01H 0
14 1426 A
126 77 VS1
-0.82 11 1387 A
121 44 01C
-1.1 16 1427 A
126 77 VS1 0.97 16 1388 A
121 44 VS4 0.05 21 1428 A
126 103 VS1 1
11 1389 A
121 44 VS4 0.76 9
1429 A
126 103 VS4
-1.01 32 1390 A
121 44 VS?
0.99 11 1430 A
126 111 VS?
1.04 17 1391 A
121 102 02H 0.84 18 1431 A
126 115 02C
-0.95 14 1392 A
121 104 VS4 0.77 13 1432 A
126 115 04C 0.76 14 1393 A
121 116 03C 0.88 16 1433 A
126 115 05H 0.96 9
1394 A
121 116 04C
-0.91 10 1434 A
126 115 VS6
-0.96 11 1395 A
121 118 03C 0.79 24 1435 A
127 52 03C
-0.32 9
1396 A
121 118 VS4
-0.76 30 1436 A
127 72 VS6
-0.21 22 Page C-18
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1437 A
127 76 VS1
-0.91 10 1477 A
131 94 08H
-0.75 14 1438 A
127 76 VS4 0.95 10 1478 A
131 94 08H 0.92 19 1439 A
127 80 06C 0.76 17 1479 A
131 94 VS1 0.9 16 1440 A
127 80 VS?
0.79 13 1480 A
131 96 06C 0.74 20 1441 A
127 106 VS4
-0.62 14 1481 A
132 67 VS2
-0.93 18 1442 A
127 108 05C
-1.02 21 1482 A
132 67 VS2 0.92 13 1443 A
127 112 03C
-0.95 26 1483 A
132 81 DBC 1.76 15 1444 A
127 114 VS4
-0.12 16 1484 A
132 87 DBH 1.78 17 1445 A
128 53 02H
-0.9 20 1485 A
132 91 DBC
-1.68 18 1446 A
128 69 08H 1.01 14 1486 A
132 93 VS2 0.71 30 1447 A
128 71 VS1
-0.83 21 1487 A
132 95 VS?
0.94 26 1448 A
128 71 VS1 0.88 33 1488 A
132 97 08C
-0.05 8
1449 A
128 71 VS2
-0.02 18 1489 A
132 97 VS?
-0.64 17 1450 A
128 77 07C 0.85 18 1490 A
132 99 DBC 1.67 15 1451 A
128 85 DBH 1.91 15 1491 A
133 64 05H
-0.09 16 1452 A
128 101 VS2
-0.71 12 1492 A
133 64 VS1 0.99 12 1453 A
128 103 VS2 1.01 10 1493 A
133 66 VS4
-0.83 15 1454 A
128 111 05C 0.79 14 1494 A
133 86 DBC
-1.53 14 1455 A
128 113 05C
-0.97 14 1495 A
133 88 DBC 1.69 16 1456 A
129 54 02C
-0.97 27 1496 A
133 92 VS6 0.94 25 1457 A
129 58 02H 0.8 31 1497 A
133 92 VS?
0.09 17 1458 A
129 58 VS2
-0.8 15 1498 A
133 94 DBC
-1.94 13 1459 A
129 74 VS1
-0.84 16 1499 A
133 94 DBC 0.97 8
1460 A
129 86 DBH 1.9 9
1500 A
133 94 VS2 0.8 15 1461 A
129 92 VS4
-0.8 13 1501 A
133 94 VS4
-0.71 19 1462 A
129 94 VS4 0
12 1502 A
133 94 VS6
-0.83 31 1463 A
129 94 VS4 0.63 13 1503 A
133 94 VS6 0.98 19 1464 A
129 112 VS2
-0.78 11 1504 A
134 65 04H
-0.84 13 1465 A
130 57 08H 0.94 20 1505 A
134 65 05H
-0.02 22 1466 A
130 71 VS4
-0.97 22 1506 A
134 65 07H
-0.14 24 1467 A
130 73 VS6 0.96 14 1507 A
134 65 08H 0.75 14 1468 A
130 73 VS?
0.85 19 1508 A
134 65 DBH
-1.8 14 1469 A
130 89 DBC
-1.79 8
1509 A
134 65 VS1 0.93 12 1470 A
130 93 DBH 2.06 13 1510 A
134 69 VS6 1.07 11 1471 A
130 95 01H 0.9 18 1511 A
134 69 VS?
0.28 21 1472 A
130 95 VS4
-0.97 22 1512 A
134 69 VS?
0.81 29 1473 A
130 99 03C
-0.21 26 1513 A
134 71 VS1
-0.79 9
1474 A
130 107 02C 0.88 20 1514 A
134 71 VS1 0.05 21 1475 A
131 70 DBC 1.66 12 1515 A
134 71 VS1 0.79 21 1476 A
131 76 06C 0.74 13 1516 A
134 89 DBC
-1.71 13 Page C-19
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1517 A
134 91 DSC 1.77 33 1557 A
136 91 07C
-1.02 18 1518 A
134 91 VS6
-0.65 21 1558 A
136 91 08C
-1.09 22 1519 A
134 91 VS6 0.96 14 1559 A
136 91 08C 0.76 28 1520 A
134 91 VS7
-0.82 30 1560 A
136 93 VS6 0.83 12 1521 A
134 99 04C
-0.91 18 1561 A
137 76 VS2
-0.74 11 1522 A
134 103 02C
-0.9 17 1562 A
137 76 VS2 0
16 1523 A
134 103 DSC
-1.51 14 1563 A
137 76 VS4
-0.67 28 1524 A
135 72 VS1
-0.83 27 1564 A
137 76 VS4
-0.07 27 1525 A
135 72 VS1 0.93 15 1565 A
137 76 VS6 0.02 15 1526 A
135 72 VS7 0.85 13 1566 A
137 78 VS4
-0.67 17 1527 A
135 76 DSC 1.73 20 1567 A
137 78 VS4 1.01 22 1528 A
135 78 08C
-1.11 25 1568 A
137 78 VS7 0.74 15 1529 A
135 78 VS1 0.95 16 1569 A
137 80 VS6
-0.87 18 1530 A
135 78 VS4 0.14 11 1570 A
137 80 VS7 0.14 17 1531 A
135 78 VS4 0.99 12 1571 A
137 80 VS7 0.84 27 1532 A
135 78 VS6 0.77 36 1572 A
137 88 VS4
-0.58 16 1533 A
135 82 08H 0.89 15 1573 A
137 88 VS6
-0.71 14 1534 A
135 82 VS4
-0.82 14 1574 A
137 88 VS6
-0.09 19 1535 A
135 86 DSC
-1.64 13 1575 A
137 90 05H
-0.82 18 1536 A
135 86 VS4 1.01 16 1576 A
137 90 DSC 0.78 13 1537 A
135 90 08C 0.68 21 1577 A
137 92 02C 0.83 16 1538 A
135 94 DSC
-1.84 30 1578 A
137 92 04C 0.9 16 1539 A
135 94 DSC 1.86 13 1579 A
137 92 05C
-0.07 32 1540 A
135 94 VS4 0.92 14 1580 A
137 92 07C
-0.83 23 1541 A
135 94 VS6
-0.71 16 1581 A
137 92 08C
-1.06 20 1542 A
135 94 VS6 0.9 25 1582 A
137 92 08C 0.85 29 1543 A
135 94 VS7
-0.6 28 1583 A
137 92 VS6
-0.84 38 1544 A
135 100 02C 0.76 20 1584 A
137 92 VS6
-0.07 28 1545 A
135 100 04C
-0.9 17 1585 A
137 92 VS6 0.95 17 1546 A
135 100 DSC 1.78 19 1586 A
138 75 07H 0.89 12 1547 A
135 100 VS6
-0.76 20 1587 A
138 75 08C 0
18 1548 A
135 100 VS7
-0.55 38 1588 A
138 75 DSH 1.99 30 1549 A
136 69 DSC
-1.63 13 1589 A
138 81 08C
-1.06 17 1550 A
136 69 VS7
-0.82 18 1590 A
138 81 08H 0.93 13 1551 A
136 69 VS7 0.92 11 1591 A
138 81 DSH 2.15 32 1552 A
136 79 07C
-0.23 32 1592 A
138 81 VS1
-0.82 11 1553 A
136 79 VS7
-0.71 13 1593 A
138 81 VS1 0.9 9
1554 A
136 79 VS7 1.02 12 1594 A
138 81 VS2
-0.07 11 1555 A
136 85 08H
-0.97 15 1595 A
138 81 VS4
-1.04 17 1556 A
136 91 06C
-0.94 21 1596 A
138 81 VS4 1.05 20 Page C-20
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1597 A
138 81 VS6
-0.85 34 1603 A
138 83 VS1
-0.65 16 1598 A
138 81 VS6 0.89 29 1604 A
138 85 08H
-0.97 15 1599 A
138 81 VS7 0.23 19 1605 A
138 85 DBC
-1.66 16 1600 A
138 81 VS7 0.9 22 1606 A
138 85 VS6 0.87 15 1601 A
138 83 08H
-1.09 15 1607 A
138 85 VS7 0.86 29 1602 A
138 83 DBH 2.19 23 1608 A
138 89 VS1 0.89 17 Page C-21
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report APPENDIX D: SUPPORT WEAR LISTING - SGB Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1
B 1
10 03C
-0.16 15 39 B
17 2
03C 0.79 11 2
B 1
36 03C 0.8 16 40 B
17 36 04H
-0.88 13 3
B 1
150 01C
-0.56 23 41 B
17 120 DBC
-1.12 18 4
B 1
158 02C 0.67 17 42 B
18 5
03C
-0.19 14 5
B 1
160 04H
-0.18 13 43 B
19 60 03H
-0.78 13 6
B 1
160 04H 0.76 17 44 B
19 138 03C
-0.88 11 7
B 2
141 03H
-0.81 19 45 B
19 164 02C 0.89 26 8
B 2
143 02C 0.76 13 46 B
21 4
03C 0.75 14 9
B 2
165 01C 0.74 20 47 B
21 8
03C
-0.97 14 10 B
3 6
02C
-0.95 13 48 B
21 58 02C 0.81 15 11 B
3 6
02C 0.81 14 49 B
21 64 DBC
-1.72 14 12 B
3 36 03C 0.79 17 so B
22 11 02C 0.79 13 13 B
3 42 03C 0.78 20 51 B
22 133 VS4 1.06 20 14 B
4 153 01H 0.77 16 52 B
22 163 02C 0.93 21 15 B
5 138 02H
-0.98 17 53 B
23 50 01H 0.82 26 16 B
6 165 02C
-1.02 21 54 B
23 106 VS4
-0.88 10 17 B
7 2
05H 0.88 12 55 B
24 7
DBH 1.75 17 18 B
7 140 04C 0.74 16 56 B
24 53 02C 0.77 13 19 B
8 3
03C
-0.18 18 57 B
25 6
02C
-0.93 11 20 B
9 140 03C 0.76 12 58 B
25 36 04H
-0.81 9
21 B
10 133 02C 0.83 12 59 B
25 40 04H
-0.87 12 22 B
11 2
02H 0.87 15 60 B
27 64 05H
-0.05 14 23 B
11 164 02C
-0.93 24 61 B
27 64 DBH
-1.71 14 24 B
11 164 04C 0.81 24 62 B
27 64 VS4
-0.23 12 25 B
12 3
03C
-0.93 15 63 B
28 39 VS4 1.02 20 26 B
13 2
04C
-0.19 11 64 B
29 120 03H 0.89 21 27 B
13 4
02H
-0.74 16 65 B
30 5
02H
-0.16 7
28 B
13 6
03C 0.77 13 66 B
30 7
03C 0.02 7
29 B
13 8
03C
-0.97 13 67 B
30 7
03C 0.72 10 30 B
13 62 05C
-0.93 18 68 B
30 9
02C 0.84 14 31 B
13 140 02H 0.89 15 69 B
30 45 VS4 1.2 18 32 B
14 37 DBH 2.19 10 70 B
30 51 02H 0.89 10 33 B
14 57 DBC
-0.75 17 71 B
30 53 02C 0.77 10 34 B
14 159 02H
-0.79 15 72 B
30 57 03C
-0.91 11 35 B
15 130 05C
-1.19 28 73 B
30 115 02H 0.87 13 36 B
15 154 04H 0.96 20 74 B
31 4
02C
-0.95 14 37 B
15 164 02H 0.82 18 75 B
31 4
03C
-0.85 14 38 B
16 155 03H
-0.12 22 76 B
31 4
03C 0.07 9
Page D-1
fram Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 77 B
31 14 05H
-0.83 14 117 B
35 46 03H
-0.83 11 78 B
31 46 01H 0.87 13 118 B
35 46 03H 0.88 13 79 B
31 50 03C 0.77 13 119 B
35 52 05C 0.91 17 80 B
31 112 01H 0.9 24 120 B
35 52 DBC 1.31 10 81 B
32 5
02C 0.77 19 121 B
35 56 03H
-0.82 15 82 B
32 5
04H 1.02 12 122 B
35 64 05H 0.95 15 83 B
32 13 03C 0.82 19 123 B
36 5
03C
-0.02 11 84 B
32 45 02H 0.92 15 124 B
36 5
03C 0.77 20 85 B
32 45 03H 0.9 13 125 B
36 41 03H
-0.87 14 86 B
32 109 04C 0.74 14 126 B
36 45 VS4
-0.72 19 87 B
32 151 VS4 1.04 19 127 B
36 49 04H 0.9 9
88 B
32 157 DBH 1.97 16 128 B
36 51 VS4
-0.74 9
89 B
33 4
01C
-0.95 12 129 B
36 51 VS4 0.88 13 90 B
33 12 VS4 0.83 16 130 B
36 109 04C 0.79 13 91 B
33 32 04H 0.97 17 131 B
36 113 03C 0.75 17 92 B
33 52 03C 0.82 12 132 B
36 119 03C
-1 11 93 B
33 54 03C
-0.95 13 133 B
36 149 VS4
-0.79 17 94 B
33 158 02C 0.76 21 134 B
36 149 VS4 0.13 16 95 B
33 162 02C
-0.94 17 135 8
36 157 02C
-0.88 21 96 B
33 162 03C 0.83 15 136 B
36 161 02H 1
16 97 B
34 11 DBC
-1.23 15 137 B
36 161 04C
-0.21 13 98 B
34 11 VS4 0.94 15 138 B
37 6
01H
-0.85 12 99 B
34 31 VS4 0.3 20 139 B
37 6
02C
-0.98 14 100 B
34 31 VS4 0.75 20 140 B
37 6
02C
-0.19 14 101 B
34 43 03H 0.94 11 141 B
37 6
03H 0.94 16 102 B
34 47 03H
-0.82 10 142 B
37 10 03C
-0.98 20 103 B
34 59 03H
-0.85 10 143 B
37 12 VS4
-0.61 15 104 B
34 103 04H
-0.71 11 144 B
37 32 03H 0.9 11 105 B
34 113 01C 0.75 12 145 B
37 36 03H
-0.92 9
106 B
34 117 04C 0.75 12 146 B
37 48 02H
-0.8 13 107 B
34 133 03C 0.77 16 147 B
37 50 02H
-0.82 11 108 B
34 161 02C 0.76 16 148 B
37 54 02H 0.93 13 109 B
35 4
01C
-0.95 15 149 B
37 54 04C 0.83 12 110 B
35 4
DBC
-0.28 14 150 B
37 122 VS4
-0.78 25 111 B
35 4
DBC 2.09 24 151 B
37 124 VS4
-0.67 16 112 B
35 6
05C
-0.28 12 152 B
37 124 VS4 0.8 22 113 B
35 36 03H 0.94 11 153 B
37 128 VS4
-0.72 19 114 B
35 36 VS4 0.81 19 154 B
37 128 VS4 0.81 20 115 B
35 42 05H 0.95 16 155 B
37 148 VS4
-0.66 25 116 B
35 46 03C 0.79 10 156 B
37 150 05H 0.89 12 Page D-2
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 157 B
37 156 VS4
-0.82 21 197 B
39 12 VS4
-0.65 19 158 B
37 156 VS4 0.87 26 198 B
39 12 VS4 0.05 21 159 B
37 160 02H 0.95 20 199 B
39 22 DBC 1.48 14 160 B
37 160 VS4
-0.34 18 200 B
39 50 VS4
-0.58 14 161 B
37 160 VS4 1.01 26 201 B
39 52 03H
-0.8 13 162 B
38 5
02C
-0.99 12 202 B
39 102 VS4
-0.69 20 163 B
38 9
03C
-1.07 14 203 B
39 102 VS4 1.03 27 164 B
38 13 VS4 0.77 16 204 B
39 108 DBH
-1.58 13 165 B
38 39 02H 0.94 14 205 B
39 116 VS4
-0.73 19 166 B
38 45 02C 0.07 20 206 B
39 116 VS4 0.8 35 167 B
38 49 02H
-0.89 11 207 B
39 120 VS4 0.96 22 168 B
38 49 VS4 0.23 12 208 B
39 122 02C
-0.91 14 169 B
38 49 VS4 0.77 18 209 B
39 122 VS4 0.84 15 170 B
38 51 02C 0.83 8
210 B
39 134 VS4
-0.87 26 171 B
38 51 VS4
-0.73 14 211 B
39 146 DBC 1.5 10 172 B
38 53 03H
-0.89 12 212 B
39 160 02H 0.87 17 173 B
38 53 VS4 0.06 18 213 B
40 5
02C
-0.93 14 174 B
38 53 VS4 1.05 12 214 B
40 17 VS4 1.07 21 175 B
38 107 02C 0.72 16 215 B
40 31 03H 0.94 15 176 B
38 115 04C 0.8 9
216 B
40 31 VS4 0.84 10 177 B
38 125 VS4
-0.78 14 217 B
40 33 VS4 0.08 13 178 B
38 125 VS4 0.02 12 218 B
40 39 04H
-0.87 10 179 B
38 125 VS4 0.88 35 219 B
40 51 01H 0.89 12 180 B
38 127 02C
-0.95 14 220 B
40 55 03H
-0.82 10 181 B
38 127 04C 0.07 11 221 B
40 115 03C 0.75 13 182 B
38 127 VS4 0.94 27 222 B
40 115 04C 0.77 14 183 B
38 131 VS4
-0.87 13 223 B
40 117 03C 0.79 21 184 B
38 131 VS4 1.01 21 224 B
40 121 VS4
-0.72 23 185 B
38 133 VS4
-0.8 14 225 B
40 121 VS4 1.01 27 186 B
38 145 VS4
-0.73 16 226 B
40 123 03C
-0.97 11 187 B
38 145 VS4 1.06 21 227 B
40 123 VS4 0.94 20 188 B
38 147 VS4
-0.68 31 228 B
40 125 02C
-0.9 18 189 B
38 147 VS4 1.09 12 229 B
40 129 04C
-0.88 16 190 B
38 161 02H 0.93 26 230 B
40 143 05H 1.02 16 191 B
39 6
02C
-0.21 10 231 B
41 6
01C
-0.97 11 192 B
39 6
02C 0.74 12 232 B
41 6
01C 0.81 10 193 B
39 8
03C
-0.98 15 233 B
41 8
04C 0.74 23 194 B
39 8
03C 0.72 11 234 B
41 12 05C 0
20 195 B
39 10 03C
-1 13 235 B
41 12 VS4
-0.75 10 196 B
39 10 03C 0.77 16 236 B
41 12 VS4 0.03 24 Page D-3
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 237 B
41 12 VS4 0.74 26 277 B
43 132 VS4 1.07 21 238 B
41 14 VS4 0.05 28 278 B
43 134 03C
-0.97 13 239 B
41 14 VS4 0.76 17 279 B
44 19 VS4 0.2 14 240 B
41 28 05H 0.99 12 280 B
44 21 VS4
-0.83 27 241 B
41 32 VS4 0.03 15 281 B
44 21 VS4 0.93 31 242 B
41 32 VS4 0.74 7
282 B
44 23 DBH
-1.62 23 243 B
41 36 03H
-0.09 10 283 B
44 23 VS4 0.98 17 244 B
41 40 02C
-0.24 9
284 B
44 27 DBC
-1.16 10 245 B
41 48 03H 0.87 13 285 B
44 27 VS4
-0.67 22 246 B
41 48 VS4
-0.76 8
286 B
44 27 VS4 0.99 24 247 B
41 54 VS4
-0.85 15 287 B
44 29 VS4
-0.77 14 248 B
41 54 VS4 0.84 28 288 B
44 29 VS4 0.03 31 249 B
41 56 02H 0.9 14 289 B
44 29 VS4 0.8 12 250 B
41 120 05C 0.82 8
290 B
44 31 02C 0.72 15 251 B
41 122 VS4
-0.84 18 291 B
44 31 DBC 1.42 22 252 B
41 128 04C
-1.03 15 292 B
44 31 VS4
-0.63 34 253 B
41 132 04C 0.12 15 293 B
44 31 VS4 0.33 19 254 B
41 132 VS4 0.84 18 294 B
44 33 VS4 0.2 10 255 B
41 134 03C 0.82 14 295 B
44 33 VS4 0.97 9
256 B
42 27 VS4
-0.69 17 296 B
44 37 VS4 0.08 28 257 B
42 37 VS4 0.03 15 297 B
44 37 VS4 0.85 12 258 B
42 39 VS4 0.08 17 298 B
44 41 02C
-0.26 18 259 B
42 41 VS4 0.21 28 299 B
44 45 03C 0.86 14 260 B
42 41 VS4 0.82 34 300 B
44 45 04C 0.89 16 261 B
42 47 03H
-0.8 12 301 B
44 45 VS4 0.93 22 262 B
42 51 VS4
-0.65 32 302 B
44 47 VS4
-0.47 19 263 B
42 51 VS4 0.31 10 303 B
44 47 VS4 0.1 22 264 B
42 51 VS4 1.2 14 304 B
44 53 VS4
-0.02 18 265 B
42 57 VS4 0.2 20 305 B
44 57 VS4
-0.75 18 266 B
42 57 VS4 0.79 37 306 B
44 57 VS4 0.1 14 267 B
42 119 VS4 1.03 18 307 B
44 59 VS4 0.08 26 268 B
42 123 VS4 0.85 32 308 B
44 59 VS4 0.92 15 269 B
42 133 02H
-0.8 12 309 B
44 63 VS4 1.02 24 270 B
43 6
02C
-0.98 14 310 B
44 65 VS4 0
23 271 B
43 6
02C
-0.19 20 311 B
44 65 VS4 0.88 21 272 B
43 6
05H
-0.21 12 312 B
44 99 DBH 1.87 14 273 B
43 8
03C 0.79 13 313 B
44 101 04C 0.81 12 274 B
43 42 05C 0.8 13 314 B
44 103 VS4 0.9 36 275 B
43 48 05C 0.81 19 315 B
44 107 VS4
-0.69 22 276 B
43 126 04C
-0.84 18 316 B
44 107 VS4 0.95 26 Page D-4
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 317 B
44 121 03C 0.77 10 357 B
45 140 VS4 0.94 29 318 B
44 127 02C 0.82 21 358 B
45 148 06C
-0.65 19 319 B
44 131 03C 0.75 18 359 B
45 148 VS4 1.07 14 320 B
44 131 VS4 0.93 12 360 B
46 7
01C
-0.28 19 321 B
44 159 01H
-0.91 16 361 B
46 7
01C 0.79 7
322 B
45 6
02C
-0.99 24 362 B
46 7
06C 1.08 15 323 B
45 6
02C
-0.21 21 363 B
46 21 VS4 0.94 11 324 B
45 16 DBH
-1.48 14 364 B
46 23 VS4
-0.85 18 325 B
45 32 VS4
-0.72 24 365 B
46 23 VS4 0.9 22 326 B
45 32 VS4 0.33 18 366 B
46 25 VS4
-0.69 12 327 B
45 32 VS4 1.14 20 367 B
46 33 DBC
-1.46 11 328 B
45 34 VS4
-0.79 15 368 B
46 33 VS4
-0.66 25 329 B
45 34 VS4 0
27 369 B
46 33 VS4 0.15 12 330 B
45 34 VS4 0.87 10 370 B
46 35 VS4
-0.69 20 331 B
45 36 VS4 0.08 22 371 B
46 37 DBC
-1.6 12 332 B
45 36 VS4 1.06 13 372 B
46 37 VS4
-0.89 14 333 B
45 38 VS4
-0.72 11 373 B
46 37 VS4 0.98 18 334 B
45 38 VS4 0.16 9
374 B
46 39 VS4 0.05 24 335 B
45 42 VS4
-0.86 27 375 B
46 39 VS4 0.85 25 336 B
45 42 VS4 1.02 22 376 B
46 41 04H 0.83 14 337 B
45 48 VS4
-0.76 13 377 B
46 47 02H
-0.14 9
338 B
45 48 VS4 0.13 17 378 B
46 59 03C 0.86 12 339 B
45 48 VS4 0.82 15 379 B
46 69 DBH
-1.61 13 340 B
45 56 03H 0.83 17 380 B
46 103 04C 0.77 14 341 B
45 64 DBC
-1.69 16 381 B
46 125 02C
-1.02 13 342 B
45 66 VS4 0.05 14 382 B
46 129 VS4 0.83 20 343 B
45 66 VS4 0.85 14 383 B
46 131 VS4
-0.95 17 344 B
45 114 03C 0.84 14 384 B
46 131 VS4 0.3 9
345 B
45 118 06H 0.21 20 385 B
46 143 DBC 1.6 11 346 B
45 120 VS4
-0.78 19 386 B
46 151 VS4 0.97 38 347 B
45 120 VS4 1.06 22 387 B
47 8
01H 0.92 8
348 B
45 122 VS4
-0.91 26 388 B
47 12 VS4
-0.7 15 349 B
45 122 VS4 1.02 31 389 B
47 12 VS4 1
22 350 B
45 126 02C 0.75 16 390 B
47 12 VS4
-0.07 12 351 B
45 128 03H
-0.82 12 391 B
47 14 VS4 0.05 23 352 B
45 130 VS4 1.19 16 392 B
47 14 VS4 0.85 24 353 B
45 132 VS4 0.95 15 393 B
47 20 VS4
-0.85 26 354 B
45 140 06C
-0.53 16 394 B
47 20 VS4 0.97 30 355 B
45 140 DBH
-1.21 18 395 B
47 22 VS4
-0.72 17 356 B
45 140 VS4
-1.03 16 396 B
47 22 VS4 1.11 16 Page D-5
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 397 B
47 34 VS4 1.01 12 437 B
48 125 03C 0.81 15 398 B
47 46 VS4
-0.71 20 438 B
48 129 03C
-0.23 11 399 B
47 46 VS4 0.02 20 439 B
48 139 03H 0.89 16 400 B
47 46 VS4 1.05 13 440 B
48 159 01H
-0.89 14 401 B
47 56 VS4
-0.75 19 441 B
49 8
VS4 1.02 25 402 B
47 56 VS4 1.02 31 442 B
49 10 01C 0.82 24 403 B
47 58 VS4 1
17 443 B
49 26 03H 0.9 13 404 B
47 70 VS4
-0.71 19 444 B
49 46 VS4
-0.72 16 405 B
47 96 VS4
-0.83 17 445 B
49 46 VS4 1.07 20 406 B
47 96 VS4 0.88 25 446 B
49 56 03H
-0.71 14 407 B
47 98 VS4 0.98 21 447 B
49 74 DBH
-1.53 30 408 B
47 102 VS4
-0.89 16 448 B
49 106 VS4 0
18 409 B
47 108 06H 0.95 23 449 B
49 122 04C 0.82 11 410 B
47 108 VS4
-0.87 20 450 B
49 124 VS4
-0.81 26 411 B
47 108 VS4 0
16 451 B
49 132 03C
-0.93 17 412 B
47 108 VS4 0.95 23 452 B
49 144 02H 0.87 10 413 B
47 114 06C 0.72 11 453 B
49 158 01C 0.02 18 414 B
47 116 04C
-0.98 13 454 B
50 7
DBH 1.68 9
415 B
47 126 VS4
-0.86 31 455 B
50 9
01C
-0.95 12 416 B
47 126 VS4 1.15 31 456 B
50 63 DBH
-1.39 15 417 B
47 128 VS4
-0.79 27 457 B
50 127 03C
-0.92 14 418 B
47 132 VS4
-0.84 13 458 B
50 157 01H
-0.89 22 419 B
47 132 VS4 0.95 13 459 B
51 36 03C
-0.95 13 420 B
47 140 VS4 1.03 15 460 B
51 36 03C 0.65 9
421 B
47 148 04C 0.79 13 461 B
51 58 01H 0.92 11 422 B
48 7
01H 0.9 11 462 B
51 58 03H 0.83 12 423 B
48 9
VS4
-0.74 32 463 B
51 64 02C 1
16 424 B
48 9
VS4 0
37 464 B
51 72 VS3
-0.8 14 425 B
48 9
VS4 0.8 18 465 B
51 134 03C
-0.95 14 426 B
48 13 VS4
-0.58 25 466 B
51 156 VS5
-0.89 25 427 B
48 13 VS4
-0.07 19 467 B
52 25 02H 0.9 14 428 B
48 13 VS4 0.33 34 468 B
52 65 03C 0.79 13 429 B
48 13 VS4 0.89 23 469 B
52 107 02C 0.76 17 430 B
48 65 VS4
-0.75 27 470 B
53 8
01C 0.7 17 431 B
48 67 VS4 0.1 23 471 B
53 60 04H 1.02 15 432 B
48 67 VS4 0.99 15 472 B
53 80 03C 0.72 20 433 B
48 99 03C 0.79 16 473 B
53 118 02C
-0.19 17 434 B
48 107 04C 0.74 18 474 B
53 120 04C 0.77 16 435 B
48 111 04C 0.75 13 475 B
53 128 03C 0.68 17 436 B
48 123 VS4 0.94 13 476 B
53 132 02C 0.82 18 Page D-6
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 477 B
54 17 VS3
-0.76 14 517 B
58 117 06C 0.79 11 478 B
54 17 VS3 1
12 518 B
59 28 DBH 1.74 9
479 B
54 71 02H 0.89 16 519 B
59 48 03C 0.79 21 480 B
54 117 02C 0.81 12 520 B
59 48 06H 1.02 15 481 B
54 143 VS3
-0.77 13 521 B
59 66 02H
-0.81 14 482 B
55 54 VS3
-0.67 14 522 B
59 70 03H
-0.72 12 483 B
55 56 03H 0.91 14 523 B
59 88 03C 0.79 12 484 B
55 60 04H 0.92 14 524 B
59 116 03C 0.84 9
485 B
55 64 02C 0.86 18 525 B
59 118 03C
-0.93 13 486 B
55 78 01C 0.84 12 526 B
59 120 03C
-0.88 12 487 B
55 96 01C 0.77 10 527 B
59 120 04H
-0.83 11 488 B
55 114 03C 0.79 14 528 B
59 122 03C
-0.23 13 489 B
55 120 04H
-0.92 12 529 B
60 29 04C
-0.3 12 490 B
55 126 03C 0.07 10 530 B
60 41 02H
-0.05 22 491 B
56 55 VS4
-0.85 13 531 B
60 81 02H 0.92 13 492 B
56 59 04H 0.99 11 532 B
60 119 03C 0.81 17 493 B
56 85 02C
-1 13 533 B
60 133 03C
-0.83 16 494 B
56 85 03C 0.81 20 534 B
61 12 06H
-0.11 15 495 B
56 97 04C 0.84 13 535 B
61 28 DBC 1.22 17 496 B
56 129 03C
-0.94 11 536 B
61 42 VS3 0.73 15 497 B
56 129 03C 0.81 19 537 B
61 48 VS3
-0.89 12 498 B
56 129 VS3 0.83 15 538 B
61 62 03H
-0.82 12 499 B
56 145 04C
-0.93 17 539 B
61 68 02H
-0.77 14 500 B
57 16 06H
-0.09 16 540 B
61 102 05C
-0.32 18 501 B
57 26 06H 1.02 17 541 B
61 120 02C
-0.96 14 502 B
57 62 04H 0.88 16 542 B
61 124 02C 0.76 15 503 B
57 80 03C 0.74 16 543 B
61 142 03C 0.84 14 504 B
57 90 03C
-1 15 544 B
62 17 VS4
-0.73 16 505 B
57 90 03C 0.78 18 545 B
62 17 VS5 0.89 14 506 B
57 120 04C
-0.16 15 546 B
62 23 VS5 0.92 14 507 B
57 142 04C 0.79 12 547 B
62 39 04H
-0.02 11 508 B
57 142 VS3 0.73 13 548 B
62 47 03C 0.72 12 509 B
57 144 04C 0.77 13 549 B
62 47 DBC
-1.35 12 510 B
57 146 DBH 1.75 10 550 B
62 53 06H 1.02 13 511 B
57 148 04C 0.75 12 551 B
62 85 DBC
-1.41 13 512 B
58 27 05H 0.99 13 552 B
62 107 02C
-0.86 13 513 B
58 47 03C
-0.93 14 553 B
62 111 03H 0.18 14 514 B
58 57 06C 0.72 13 554 B
62 155 01H
-0.83 12 515 B
58 59 02H
-0.14 12 555 B
62 155 01H
-0.09 13 516 B
58 63 04H 0.85 11 556 B
62 155 01H 0.87 15 Page D-7
Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 557 s
63 70 04H 0.94 17 597 s
66 107 02C
-1 14 558 s
63 82 VS4 1.02 26 598 s
66 107 02H
-0.82 14 559 s
63 82 VS5 1.09 23 599 s
66 125 02C 0.74 16 560 s
63 110 03H
-0.11 15 600 s
66 143 VS5 0.89 16 561 s
63 126 VS3 1.01 12 601 s
66 149 06H 0.94 16 562 s
63 128 06C 0.78 12 602 s
66 153 VS3 0.69 18 563 s
63 136 03C 0.79 16 603 s
67 36 06H 1
12 564 s
63 136 VS5 1.04 16 604 s
67 46 DSC 1.83 13 565 s
63 138 03C 0.84 14 605 s
67 56 02C 0.79 13 566 s
63 138 DSH 1.75 13 606 s
67 56 02H 0.97 12 567 s
63 140 03C 0.81 16 607 s
67 56 03C 0.75 15 568 s
64 37 06H
-0.14 14 608 s
67 56 04H
-0.79 14 569 s
64 51 VS5 0
18 609 s
67 58 03C 0.77 18 570 s
64 51 VS5 0.85 14 610 s
67 62 02C
-0.21 11 571 s
64 103 04C 0.81 12 611 s
67 62 03C 0.77 19 572 s
64 147 DSH 1.85 12 612 s
67 76 02H
-0.79 13 573 s
65 16 06H
-0.14 15 613 s
67 104 03H 1.09 14 574 s
65 16 VS3
-0.6 16 614 s
67 104 06C
-0.19 24 575 s
65 32 VS3
-0.63 11 615 s
67 108 03H 0.95 13 576 s
65 62 04H
-1.17 21 616 s
67 128 06H 0.29 13 577 s
65 110 03H 0.9 18 617 s
67 128 VS3 1.03 29 578 s
65 118 02C 0.81 13 618 s
67 134 03C 0.79 16 579 s
65 122 02C 0.82 11 619 s
67 134 06C
-1.05 27 580 s
65 122 06C 0.83 13 620 s
67 136 DSH
-1.63 19 581 s
66 17 06H 0.92 19 621 s
67 138 03C 0.35 28 582 s
66 21 06H 0.58 24 622 s
67 138 VS3 0.28 22 583 s
66 29 06C
-1.03 11 623 s
67 148 DSH 1.84 19 584 s
66 31 06C 0.85 11 624 s
67 148 VS3 1.01 15 585 s
66 35 06C 0.83 15 625 s
67 150 VS3
-0.5 18 586 s
66 39 VS5
-1 15 626 s
67 150 VS3 1.08 21 587 s
66 41 DSC
-1.82 9
627 s
68 17 04H 0.97 13 588 s
66 41 VS3
-0.67 14 628 s
68 21 VS5
-0.95 13 589 s
66 41 VS3
-0.09 10 629 s
68 41 04H 0.96 19 590 s
66 41 VS4
-0.79 13 630 s
68 45 DSC
-1.26 12 591 s
66 45 06C 0.84 11 631 s
68 85 02C
-0.92 17 592 s
66 47 06C
-0.14 10 632 s
68 93 04C
-0.93 20 593 s
66 51 04C
-0.37 14 633 s
68 93 04C
-0.19 15 594 s
66 51 06C 0.75 11 634 s
68 109 02H 0.87 15 595 s
66 51 06H 0.94 15 635 s
68 113 03H 0.9 12 596 s
66 97 01C 0.77 14 636 s
68 113 04H
-0.76 10 Page D-8
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 637 B
68 113 04H 1.01 20 677 B
70 51 03C 0.81 15 638 B
68 143 06H 0.86 16 678 B
70 75 03H
-0.02 17 639 B
68 151 VS3
-0.53 24 679 B
70 107 02H
-0.85 13 640 B
69 16 VS3
-0.64 17 680 B
70 109 VS4
-1.2 17 641 B
69 28 06C 0.89 17 681 B
70 129 06C
-0.9 20 642 B
69 28 06H
-0.78 16 682 B
70 141 VS3
-0.8 20 643 B
69 28 06H 0
15 683 B
70 143 DBC 1.2 9
644 B
69 34 DBC 1.22 20 684 B
70 147 VS3
-0.66 16 645 B
69 36 04C 0.74 13 685 B
70 153 03C 0
21 646 B
69 36 DBC 1.24 11 686 B
70 153 VS4
-0.78 19 647 B
69 48 04C 0.05 11 687 B
70 153 VS4 1.14 20 648 B
69 52 VS3 0.02 24 688 B
71 14 02H
-0.88 14 649 B
69 52 VS4
-0.8 23 689 B
71 14 VS4 1.11 20 650 B
69 52 VS4 0.05 22 690 B
71 20 DBC 1.36 15 651 B
69 52 VS5
-0.95 16 691 B
71 20 DBH
-1.42 18 652 B
69 52 VS5 1
16 692 B
71 20 VS5 0.96 17 653 B
69 72 06C
-0.94 18 693 B
71 36 DBC
-1.7 9
654 B
69 102 03H 1
11 694 B
71 36 DBC 1.43 9
655 B
69 106 06H
-0.65 11 695 B
71 36 VS3 0.12 16 656 B
69 120 03C 0.02 13 696 B
71 36 VS3 0.94 18 657 B
69 120 03C 0.79 18 697 B
71 36 VS4 1.03 19 658 B
69 124 03C
-0.95 16 698 B
71 36 VS5
-0.73 13 659 B
69 128 03C 0.79 18 699 B
71 36 VS5 0.07 25 660 B
69 132 04H 0.92 17 700 B
71 38 05H 0.96 16 661 B
69 134 VS3
-0.66 22 701 B
71 42 04H
-0.8 11 662 B
69 134 VS4
-0.83 36 702 B
71 46 04H
-0.82 10 663 B
69 134 VS4 1.09 26 703 B
71 52 03C 0.79 16 664 B
69 136 VS5
-0.88 23 704 B
71 86 02C
-0.92 18 665 B
69 136 VS5 0.89 17 705 B
71 86 02C
-0.18 11 666 B
69 140 VS3 1.08 18 706 B
71 86 VS5
-0.86 18 667 B
69 140 VS4 1.04 12 707 B
71 102 05C 0.76 15 668 B
69 140 VS5
-0.86 22 708 B
71 132 VS5 0.99 16 669 B
69 144 VS3
-0.74 20 709 B
71 136 06C
-1 22 670 B
69 144 VS5
-0.89 27 710 B
71 136 06C
-0.26 13 671 B
69 150 VS3
-0.67 29 711 B
71 138 VS3
-0.68 13 672 B
69 150 VS3 1.06 22 712 B
71 142 DBC 1.15 9
673 B
69 150 VS5 0.88 21 713 B
71 144 DBC 1.45 16 674 B
70 31 06C 0.8 11 714 B
71 144 VS3
-0.74 30 675 B
70 45 03H 0.84 11 715 B
71 144 VS3 1.04 18 676 B
70 47 04C
-0.23 9
716 B
71 146 06H 0.66 16 Page D-9
e Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 717 B
71 146 VS4 1.09 15 757 B
74 19 DBC
-1.25 15 718 B
71 146 VS5
-0.88 33 758 B
74 19 VS4
-0.8 12 719 B
72 17 DBH 1.52 17 759 B
74 21 VS3 1.2 13 720 B
72 19 VS3 0.14 16 760 B
74 23 DBC 1.12 14 721 B
72 23 VS3 0.87 16 761 B
74 23 VS3
-0.86 19 722 B
72 25 DBC 1.3 12 762 B
74 23 VS4
-0.81 17 723 B
72 25 VS3
-0.51 24 763 B
74 37 04C
-0.97 12 724 B
72 41 06C 0.82 24 764 B
74 37 06H 1
13 725 B
72 47 03C
-1 14 765 B
74 37 DBC 1.59 10 726 B
72 49 03C 0.86 31 766 B
74 43 VS3
-0.82 13 727 B
72 55 VS3
-0.79 16 767 B
74 43 VS4
-0.77 19 728 B
72 57 03C
-1 11 768 B
74 45 VS5
-1.06 15 729 B
72 59 04C 0.77 14 769 B
74 47 06C 0.05 10 730 B
72 61 02C 0.81 15 770 B
74 51 03C
-0.91 14 731 B
72 63 02C 0.88 12 771 B
74 53 VS3
-0.77 12 732 B
72 85 05C 0.75 16 772 B
74 55 04C 0.79 19 733 B
72 113 02H
-0.8 12 773 B
74 107 04H
-0.84 12 734 B
72 113 02H 0.94 9
774 B
74 117 VS3
-1.01 16 735 B
72 113 04C 0.82 12 775 B
74 119 03H 0.85 18 736 B
72 113 04H 0.9 11 776 B
74 119 04H 1.01 19 737 B
72 125 06C 0.83 23 777 B
74 127 DBH
-1.55 19 738 B
72 131 DBH 1.53 12 778 B
74 141 VS5
-0.83 18 739 B
72 133 01H 0.97 18 779 B
75 16 02H 0.9 15 740 B
72 133 VS5
-0.73 13 780 B
75 16 06H 0.98 14 741 B
72 149 DBH 1.85 28 781 B
75 24 DBC
-1.3 13 742 B
72 149 VS3 1.03 22 782 B
75 24 VS3 0.12 14 743 B
73 14 VS4
-0.91 10 783 B
75 36 VS3 0.81 17 744 B
73 14 VS4 0.46 9
784 B
75 42 04C 0.77 17 745 B
73 20 VS5 0.76 15 785 B
75 58 02H
-0.79 18 746 B
73 40 05H 1.05 12 786 B
75 60 03C 0.77 18 747 B
73 58 06C
-0.35 17 787 B
75 82 01H 0.88 19 748 B
73 80 01H 0.71 19 788 B
75 102 04H 0.9 17 749 B
73 86 02C
-1 12 789 B
75 104 03H 0.97 24 750 B
73 104 06C
-0.95 16 790 B
75 106 02H
-0.78 13 751 B
73 106 03H 0.94 12 791 B
75 110 04C
-1 15 752 B
73 122 01H 0.89 14 792 B
75 134 VS4
-0.81 10 753 B
73 132 06H 1.03 14 793 B
76 15 DBH 1.64 19 754 B
74 17 VS3
-0.72 26 794 B
76 21 VS3 0.99 12 755 B
74 17 VS3 1.05 15 795 B
76 21 VS4
-0.87 14 756 B
74 17 VS4
-0.93 25 796 B
76 21 VS4 1.04 25 Page D-10
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 797 B
76 25 06H 1.07 17 837 B
78 109 03H 0.96 15 798 B
76 29 VS3
-0.89 14 838 B
79 24 VS3
-0.63 13 799 B
76 29 VS3 0.07 22 839 B
79 24 VS3 1.04 11 800 B
76 29 VS3 0.74 19 840 B
79 24 VS4 0.14 26 801 B
76 29 VS4 0.08 22 841 B
79 24 VS4 0.92 26 802 B
76 33 DBH 1.94 16 842 B
79 44 03C 0.82 13 803 B
76 35 DBH 1.6 22 843 B
79 52 02C
-0.28 15 804 B
76 51 VS3 0.87 20 844 B
79 54 03C 0.74 11 805 B
76 59 05H 1
13 845 B
79 86 03H 0.9 19 806 B
76 59 VS3
-0.75 14 846 B
79 92 01H
-0.74 19 807 B
76 65 VS4
-0.07 8
847 B
79 98 06H 1.04 25 808 B
76 117 DBC
-0.82 10 848 B
79 128 03C 0.72 13 809 B
76 121 04C 0.7 16 849 B
80 17 DBH 1.56 28 810 B
76 127 DBH
-1.53 12 850 B
80 49 VS3
-0.82 14 811 B
76 141 DBH 1.88 21 851 B
80 49 VS4
-0.93 15 812 B
76 151 04C 0.86 16 852 B
80 95 02H 0.9 12 813 B
77 34 VS3 0.14 13 853 B
80 95 03H 1.06 13 814 B
77 34 VS3 0.88 24 854 B
80 95 04H 0.95 17 815 B
77 48 VS4 1.11 19 855 B
80 97 VS3 0
15 816 B
77 50 05H
-0.71 10 856 B
80 115 VS4
-0.91 18 817 B
77 86 02C
-1 10 857 B
80 145 VS4
-0.69 31 818 B
77 86 02C 0.77 13 858 B
80 145 VS5
-1.01 11 819 B
77 104 05C 0.72 17 859 B
80 145 VS5 0.79 20 820 B
77 104 05H 1
16 860 B
80 149 01H
-0.78 14 821 B
77 116 04H
-0.87 14 861 B
81 22 VS3 0.82 28 822 B
77 150 DBH 1.85 18 862 B
81 22 VS4 1.2 26 823 B
77 150 VS4
-0.87 19 863 B
81 24 VS3
-0.75 16 824 B
77 150 VS4 1.09 24 864 B
81 24 VS3 0.87 12 825 B
78 23 DBH
-1.42 19 865 B
81 52 VS3 0.96 26 826 B
78 23 VS5 1.13 11 866 B
81 60 03C 0.77 13 827 B
78 35 DBH
-1.35 14 867 B
81 92 02C
-0.9 17 828 B
78 47 02C 0.79 18 868 B
81 112 02H 0.91 14 829 B
78 57 03C 0.79 23 869 B
81 126 07C 0.67 19 830 B
78 61 VS3
-0.84 24 870 B
81 148 03C 0.79 10 831 B
78 79 VS4 1.03 12 871 B
81 148 04C 0.74 17 832 B
78 81 03H 1.02 12 872 B
81 148 VS4
-0.89 13 833 B
78 87 03C
-0.91 19 873 B
81 148 VS4 1.04 17 834 B
78 105 02H
-0.83 15 874 B
82 19 VS4 0.96 13 835 B
78 109 02H
-0.8 10 875 B
82 21 VS5
-0.92 13 836 B
78 109 03H 0.18 10 876 B
82 41 VS3 1.03 19 Page D-11
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 877 B
82 43 VS3
-0.73 11 917 B
85 36 VS6
-0.9 19 878 B
82 43 VS3 0.05 27 918 B
85 78 05H 0.95 18 879 B
82 43 VS3 0.82 22 919 B
85 110 04C 0.79 15 880 B
82 43 VS4
-0.77 11 920 B
85 140 04C 0.79 11 881 B
82 43 VS4
-0.02 14 921 B
85 142 03C
-0.9 18 882 B
82 43 VS4 0.85 24 922 B
85 144 03C
-0.92 15 883 B
82 43 VS5
-0.82 26 923 B
86 51 03C 0.81 19 884 B
82 43 VS5
-0.14 19 924 B
86 79 04H 0.85 14 885 B
82 43 VS5 0.24 23 925 B
86 89 03C 0.77 18 886 B
82 43 VS5 0.81 15 926 B
86 91 03C
-0.96 13 887 B
82 91 04C
-0.91 17 927 B
86 111 04C
-0.98 13 888 B
82 129 DBH 2.06 18 928 B
87 20 VS4
-0.9 16 889 B
82 137 DBH 1.77 12 929 B
87 38 VS6
-0.82 13 890 B
82 143 VS3
-0.9 28 930 B
87 62 04C
-0.97 13 891 B
82 143 VS4
-0.85 18 931 B
87 82 03H 0.9 17 892 B
82 145 VS3
-0.88 21 932 B
87 84 02C 0.44 20 893 B
82 145 VS3 0.94 18 933 B
87 88 04C
-0.93 17 894 B
82 145 VS4
-0.96 14 934 B
87 146 03C 0.77 29 895 B
82 145 VS4 1.04 27 935 B
87 146 VS4
-0.83 18 896 B
83 20 DBH 1.91 8
936 B
87 146 VS4 1.05 17 897 B
83 28 VS6
-0.82 21 937 B
88 27 DBH 2.08 18 898 B
83 28 VS6 0.81 14 938 B
88 29 06H 1.03 14 899 B
83 54 04H 0.97 15 939 B
88 87 05C 0.73 13 900 B
83 64 03C 0.83 15 940 B
88 95 03C 0.79 18 901 B
83 106 03H 0.89 16 941 B
88 107 04C
-1 14 902 B
83 148 VS4
-0.97 29 942 B
89 38 05H
-0.79 9
903 B
84 19 07H
-0.96 18 943 B
89 38 VS2
-0.76 14 904 B
84 77 05C
-0.95 16 944 B
89 42 VS6 1.12 14 905 B
84 79 03H 0.99 14 945 B
89 44 VS6
-0.9 13 906 B
84 81 02C 0.84 16 946 B
89 60 04C
-0.98 14 907 B
84 81 VS5
-1.01 17 947 B
89 78 07C 0.97 15 908 B
84 87 03H 1.02 14 948 B
89 82 07C 0.73 15 909 B
84 93 02C
-0.95 15 949 B
89 84 03H 0.95 16 910 B
84 107 02H
-0.78 12 950 B
89 92 04C 0.42 20 911 B
84 125 04H
-0.81 12 951 B
89 100 03H 0.85 16 912 B
84 145 03C
-0.88 16 952 B
89 104 04C
-1.04 12 913 B
84 147 DBH 1.89 29 953 B
89 104 04H 1
11 914 B
85 20 VS4
-0.78 11 954 B
89 104 05C
-1.03 11 915 B
85 20 VS4 1.01 15 955 B
90 23 VS4
-0.74 15 916 B
85 36 04H
-0.85 15 956 B
90 55 VS2 1.04 16 Page D-12
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 957 B
90 65 02H 0.8 17 997 B
93 62 02C 0.81 11 958 B
90 65 03C 0.74 15 998 B
93 62 03C 0.81 12 959 B
90 87 02C
-1.04 13 999 B
93 98 04C
-0.95 10 960 B
90 87 02C
-0.23 12 1000 B
93 104 04H
-0.69 11 961 B
90 95 04C 0.84 18 1001 B
93 112 VS6 0.82 14 962 B
90 97 04C 0.81 17 1002 B
93 132 04H 0.91 15 963 B
90 99 02H 0.91 23 1003 B
94 37 VS2
-0.77 14 964 B
90 103 03H 0.14 23 1004 B
94 93 04C
-0.97 14 965 B
90 115 03H
-0.82 13 1005 B
94 93 04C
-0.23 17 966 B
90 127 04H
-0.75 16 1006 B
94 101 06H
-0.71 17 967 B
91 22 VS6 1
28 1007 B
94 111 VS6
-0.69 16 968 B
91 32 02C
-0.93 17 1008 B
94 115 04C
-0.97 15 969 B
91 38 03H
-0.8 11 1009 B
94 129 04H 0.9 18 970 B
91 54 02C 0.86 14 1010 B
95 24 VS4
-0.05 13 971 B
91 58 03C 0.81 17 1011 B
95 24 VS4 0.86 11 972 B
91 64 03C
-0.93 19 1012 B
95 36 VS4
-0.76 15 973 B
91 86 VS6 0.89 20 1013 B
95 36 VS4 1.01 17 974 B
91 88 04H
-0.62 13 1014 B
95 42 DBC
-0.48 17 975 B
91 94 06C
-0.9 14 1015 B
95 70 VS6
-0.82 17 976 B
91 124 04C 0.8 17 1016 B
95 84 07C 0.7 21 977 B
91 144 VS4
-0.89 16 1017 B
95 102 05H 0.96 19 978 B
91 144 VS4 0.91 17 1018 B
95 106 04C
-1.01 20 979 B
92 23 03H
-0.75 9
1019 B
95 116 VS2
-1 16 980 B
92 23 VS4
-0.9 9
1020 B
95 126 04H 0.92 12 981 B
92 23 VS4 0.72 10 1021 B
95 134 VS2 0.09 14 982 B
92 31 VS2
-0.76 17 1022 B
95 134 VS2 0.88 17 983 B
92 31 VS2 0.82 11 1023 B
95 136 03C
-0.41 16 984 B
92 49 05H 0.85 16 1024 B
95 138 VS4 0.96 39 985 B
92 55 03C 0.72 14 1025 B
95 140 03C
-0.96 17 986 B
92 57 04H 0.94 15 1026 B
95 142 01H 0.95 14 987 B
92 69 04C 0.83 14 1027 B
95 142 VS4 1.01 20 988 B
92 73 VS2 0.95 12 1028 B
96 25 02H
-0.83 12 989 B
92 75 05H 1.06 10 1029 B
96 29 VS4 0.83 16 990 B
92 83 05H 0.97 22 1030 B
96 57 02H 0.9 14 991 B
92 95 05C 0.81 12 1031 B
96 79 VS2 0.81 14 992 B
92 97 04C 0
8 1032 B
96 95 VS2
-0.71 20 993 B
92 97 04C 0.74 15 1033 B
96 95 VS2 0.25 12 994 B
92 105 04C
-0.95 11 1034 B
96 95 VS2 0.96 20 995 B
93 30 VS4
-0.89 19 1035 B
96 117 VS2 0.88 16 996 B
93 42 VS2 0.9 18 1036 B
96 137 03C 0.76 14 Page 0-13
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1037 B
96 137 04C
-0.21 16 1077 B
99 50 05H 0.62 19 1038 B
96 137 VS4
-0.23 16 1078 B
99 52 03C 0.79 12 1039 B
96 137 VS4 0.93 24 1079 B
99 132 VS2
-0.7 24 1040 B
96 139 03C
-0.99 20 1080 B
99 132 VS2
-0.14 13 1041 B
96 141 VS4 0.98 23 1081 B
99 132 VS2 0.72 29 1042 B
97 26 VS4
-0.66 16 1082 B
99 132 VS4 1.07 21 1043 B
97 28 03C 0.7 23 1083 B
99 136 04C 0.77 18 1044 B
97 38 05H 1.12 12 1084 B
100 27 VS4
-0.85 20 1045 B
97 40 VS2
-0.82 14 1085 B
100 27 VS4 0.8 12 1046 B
97 42 VS2
-0.81 15 1086 B
100 29 03C 0.7 18 1047 B
97 60 06C 0.69 16 1087 B
100 29 VS6
-0.85 16 1048 B
97 60 VS2 0.91 17 1088 B
100 109 VS2
-0.56 21 1049 B
97 72 04H 0.99 15 1089 B
100 121 06C 0.86 13 1050 B
97 84 07C
-0.89 17 1090 B
100 125 VS2
-0.67 34 1051 B
97 130 04H 0.86 14 1091 B
100 125 VS2 0.11 39 1052 B
97 140 VS4
-0.83 12 1092 B
100 125 VS2 0.87 17 1053 B
98 27 04C
-0.98 23 1093 B
100 125 VS4 1.07 27 1054 B
98 27 VS4
-0.83 16 1094 B
100 125 VS6 1
22 1055 B
98 27 VS4 1
16 1095 B
100 133 VS4
-0.8 16 1056 B
98 39 VS4 0.7 13 1096 B
101 28 VS4
-0.69 15 1057 B
98 41 VS2
-0.78 12 1097 B
101 28 VS4
-0.02 12 1058 B
98 41 VS2 1.04 20 1098 B
101 30 03C
-0.93 21 1059 B
98 41 VS4 0.82 25 1099 B
101 30 03C 0.72 14 1060 B
98 49 VS2
-0.5 19 1100 B
101 30 03H
-0.77 12 1061 B
98 55 VS2
-0.75 29 1101 B
101 30 04C 0.75 20 1062 B
98 61 02H 0.37 18 1102 B
101 32 VS2 0.72 22 1063 B
98 71 VS2 0.98 18 1103 B
101 36 05H 0.99 12 1064 B
98 79 03C 0.79 12 1104 B
101 38 DBC 1.34 9
1065 B
98 81 VS4
-0.76 24 1105 B
101 54 02C 0.72 17 1066 B
98 93 03C 0.69 20 1106 B
101 98 04C
-1.09 16 1067 B
98 117 VS2 0.83 18 1107 B
101 104 DBH 1.95 15 1068 B
98 133 02C 0.78 15 1108 B
101 124 VS4
-0.65 12 1069 B
98 135 VS2 0.07 19 1109 B
101 136 03H 0.87 14 1070 B
98 135 VS4
-0.75 23 1110 B
102 31 02C
-0.99 18 1071 B
98 135 VS4 0.98 24 1111 B
102 33 03C
-0.89 21 1072 B
98 139 03C
-0.71 17 1112 B
102 35 03C 0.77 20 1073 B
98 139 04H
-0.11 11 1113 B
102 41 06H 0.98 15 1074 B
98 139 VS4 0.17 24 1114 B
102 49 VS2 0.97 12 1075 B
98 139 VS4 0.88 17 1115 B
102 51 07C 1.01 19 1076 B
99 32 02C 0.86 12 1116 B
102 85 VS6
-0.75 26 Page D-14
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1117 B
102 99 07C 0.07 11 1157 B
105 34 02C 0.09 22 1118 B
102 99 07C 1
18
- 1158 B
105 36 04H
-0.11 11 1119 B
102 113 DBH 2.14 12 1159 B
105 38 03C 0.74 20 1120 B
102 127 VS4 0.83 11 1160 B
105 42 07C 0.78 13 1121 B
102 137 VS4
-0.82 14 1161 B
105 54 VS6
-0.79 24 1122 B
102 137 VS4 1.02 18 1162 B
105 58 VS2
-0.8 22 1123 B
103 36 07H 1.06 11 1163 B
105 58 VS4
-0.61 18 1124 B
103 48 07C 0.14 12 1164 B
105 58 VS4 0.12 16 1125 B
103 48 DBC
-1.52 11 1165 B
105 58 VS6 0.73 19 1126 B
103 48 VS4
-0.77 16 1166 B
105 76 VS2 1.1 20 1127 B
103 62 03C 0.77 16 1167 B
105 78 VS2
-0.27 13 1128 B
103 64 VS2 0.96 27 1168 B
105 78 VS2 1.02 14 1129 B
103 94 VS2
-0.74 18 1169 B
105 78 VS6
-0,81 24 1130 B
103 100 07C 0.84 12 1170 B
105 78 VS6 0.93 27 1131 B
103 108 VS6
-0.7 20 1171 B
105 80 VS2
-0.25 21 1132 B
103 122 03H 0.84 17 1172 B
105 88 07C
-0.56 16 1133 B
103 126 VS2 0.18 31 1173 B
105 88 VS2
-0.91 12 1134 B
103 126 VS4
-0.57 20 1174 B
105 90 03C 0.46 15 1135 B
103 126 VS6 0.88 32 1175 B
105 90 07C 0.9 15 1136 B
103 128 04C 0.79 12 1176 B
105 90 VS2 0.88 17 1137 B
103 130 VS2
-0.02 20 1177 B
105 90 VS4 1.05 18 1138 B
103 132 VS2
-0.05 21 1178 B
105 96 04C
-1 13 1139 B
103 136 VS4
-0.79 20 1179 B
105 110 DBH 0.93 22 1140 B
103 136 VS4 1.02 23 1180 B
105 116 03H 0.88 15 1141 B
104 31 02C
-0.23 21 1181 B
105 118 DBH 1.99 14 1142 B
104 31 VS4 0.76 24 1182 B
105 130 03C 0.82 19 1143 B
104 33 03H 0.18 12 1183 B
105 130 VS2
-0.73 14 1144 B
104 59 VS4 1.01 13 1184 B
105 130 VS2 0
17 1145 B
104 59 VS6
-0.77 12 1185 B
105 134 02C 0.76 21 1146 B
104 79 VS6
-0.81 17 1186 B
105 134 VS4 1.11 18 1147 B
104 95 VS2
-0.58 15 1187 B
106 31 03C 0.8 18 1148 B
104 95 VS2 0.2 16 1188 B
106 31 VS4 0.29 16 1149 B
104 95 VS2 0.86 18 1189 B
106 31 VS4 0.91 25 1150 B
104 133 VS2
-0.74 10 1190 B
106 33 03C 0.02 17 1151 B
105 30 02C 0.79 17 1191 B
106 35 02C
-0.16 13 1152 B
105 30 VS4 0.26 13 1192 B
106 35 03C 0.7 14 1153 B
105 30 VS4 0.87 29 1193 B
106 35 03H 0.95 13 1154 B
105 32 01H 0.96 12 1194 B
106 35 04H 0.98 17 1155 B
105 32 VS4
-1.11 10 1195 B
106 37 VS2
-0.58 18 1156 B
105 32 VS4 1.19 13 1196 B
106 39 03C 0.76 24 Page D-15
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1197 B
106 39 VS2
-0.65 23 1237 B
107 130 02H 0.95 15 1198 B
106 49 04H
-0.07 11 1238 B
107 130 03H 0.89 18 1199 B
106 51 07C 0.86 17 1239 B
107 132 03C 0.79 33 1200 B
106 51 VS2 1.03 13 1240 B
108 33 08H 0.95 24 1201 B
106 57 VS2 1.08 23 1241 B
108 33 DBH
-1.26 15 1202 B
106 63 VS2 0.09 29 1242 B
108 33 VS4 0.93 32 1203 B
106 63 VS4
-0.76 17 1243 B
108 37 03C
-0.36 26 1204 B
106 75 VS2 0.98 18 1244 B
108 37 04C
-0.96 14 1205 B
106 77 VS2 1.06 21 1245 B
108 43 VS4
-0.81 18 1206 B
106 101 VS2
-0.68 13 1246 B
108 45 07C 0.78 18 1207 B
106 101 VS2
-0.23 10 1247 B
108 47 VS2
-0.6 26 1208 B
106 113 VS2 0
23 1248 B
108 49 05H 0.99 15 1209 B
106 129 04C 0.79 15 1249 B
108 51 VS2
-0.66 26 1210 B
107 32 VS4
-0.71 15 1250 B
108 51 VS2 1.01 14 1211 B
107 34 VS6
-0.77 12 1251 B
108 59 VS2
-0.85 20 1212 B
107 36 VS2 0.9 22 1252 B
108 59 VS2 0.97 20 1213 B
107 40 VS2 0.9 18 1253 B
108 113 VS4
-0.84 23 1214 B
107 42 VS2
-0.8 33 1254 B
108 113 VS4 0.99 22 1215 B
107 42 VS2 0.92 35 1255 B
108 115 07C 0.78 17 1216 B
107 42 VS4 0.17 25 1256 B
108 131 02C 0.76 20 1217 B
107 42 VS4 0.94 32 1257 B
108 131 03C 0.02 13 1218 B
107 42 VS6
-0.84 18 1258 B
108 133 02C 0.07 18 1219 B
107 42 VS6 0.93 12 1259 B
108 133 VS2 0.76 12 1220 B
107 44 06C
-0.32 17 1260 B
109 34 04C 0
20 1221 B
107 46 VS2 0.99 16 1261 B
109 34 VS4
-0.69 20 1222 B
107 46 VS6
-0.74 21 1262 B
109 40 VS2
-0.9 19 1223 B
107 46 VS6 1
11 1263 B
109 40 VS2 0.76 18 1224 B
107 52 07C 0.82 12 1264 B
109 40 VS4 0.22 18 1225 B
107 52 VS6
-0.6 16 1265 B
109 48 VS4
-0.7 14 1226 B
107 58 DBH 1.88 15 1266 B
109 52 VS2
-0.86 20 1227 B
107 78 VS2
-0.93 16 1267 B
109 52 VS2 0.93 38 1228 B
107 78 VS2 0.9 23 1268 B
109 52 VS6 1.09 13 1229 B
107 82 VS2
-0.9 33 1269 B
109 62 07C 0.71 25 1230 B
107 82 VS2 0.91 29 1270 B
109 64 08C
-0.44 11 1231 B
107 82 VS4 0.12 14 1271 B
109 78 04C
-0.95 17 1232 B
107 96 VS2 0.77 30 1272 B
109 84 04H
-0.09 10 1233 B
107 116 VS2
-0.68 29 1273 B
109 96 VS2
-1.15 11 1234 B
107 116 VS2 0.02 29 1274 B
109 104 VS2 1
24 1235 B
107 116 VS2 0.81 31 1275 B
109 112 07C 0.78 16 1236 B
107 120 DBC 1.32 16 1276 B
109 112 07H 0.99 20 Page D-16
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1277 B
109 112 VS2
-0.95 15 1317 B
112 53 VS2
-0.84 17 1278 B
109 114 VS2
-0.88 14 1318 B
112 53 VS2 0.9 15 1279 B
109 114 VS2 0.09 33 1319 B
112 59 VS2 0.16 13 1280 B
109 114 VS4
-0.84 37 1320 B
112 59 VS2 0.86 14 1281 B
109 114 VS6
-0.83 29 1321 B
112 71 VS2
-0.76 12 1282 B
109 126 04H 0.94 20 1322 B
112 79 VS2 0.7 22 1283 B
109 130 02C 0.76 25 1323 B
112 127 03C 0.09 26 1284 B
109 130 03C 0.81 13 1324 B
113 36 02C 0.74 15 1285 B
109 130 04C 0.7 10 1325 B
113 36 VS2
-0.51 12 1286 B
109 130 VS2
-0.83 15 1326 B
113 36 VS2 0.85 14 1287 B
109 132 04C
-0.07 21 1327 B
113 36 VS6
-0.8 18 1288 B
109 132 05C 0.79 19 1328 B
113 38 VS4
-0.86 12 1289 B
110 37 03C
-0.99 11 1329 B
113 40 03C
-0.56 21 1290 B
110 37 04C
-1.03 16 1330 B
113 40 04H
-0.07 14 1291 B
110 51 05H 0.93 14 1331 B
113 40 VS4
-0.83 15 1292 B
110 55 VS2
-0.82 31 1332 B
113 42 05H
-0.02 14 1293 B
110 55 VS2 0.88 13 1333 B
113 42 VS4 0.95 18 1294 B
110 79 VS2
-0.02 25 1334 B
113 44 01H 0.9 15 1295 B
110 97 08H 1.67 19 1335 B
113 70 07C 0.02 19 1296 B
110 97 VS2
-0.67 15 1336 B
113 70 07C 0.77 19 1297 B
110 131 03C
-0.83 15 1337 B
113 84 02H
-0.78 18 1298 B
110 131 03C 0.79 25 1338 B
113 84 04H
-0.65 10 1299 B
111 40 DBC
-1.85 10 1339 B
113 110 04C 0.8 16 1300 B
111 50 VS2 0.82 20 1340 B
113 122 03C
-1.05 16 1301 B
111 56 08H 0.12 14 1341 B
113 130 VS4
-0.83 19 1302 B
111 66 07H 1.01 14 1342 B
114 37 04C 0.81 13 1303 B
111 84 04H
-0.78 11 1343 B
114 37 DBH 1.5 26 1304 B
111 128 03H
-0.83 11 1344 B
114 37 VS2
-0.59 23 1305 B
111 130 02H 0.2 17 1345 B
114 37 VS2 0.13 29 1306 B
111 130 VS4 0.94 24 1346 B
114 37 VS4
-0.66 23 1307 B
112 37 04C
-1.03 34 1347 B
114 37 VS4 1
28 1308 B
112 39 02H 0.94 12 1348 B
114 39 VS2
-0.78 27 1309 B
112 43 VS2
-0.81 20 1349 B
114 39 VS4 0.87 36 1310 B
112 43 VS2 0.9 18 1350 B
114 127 03C 0.81 23 1311 B
112 43 VS4
-0.72 17 1351 B
114 127 05C 0.81 15 1312 B
112 45 03H 0.83 13 1352 B
114 129 VS4
-0.78 10 1313 B
112 45 VS2
-0.78 12 1353 B
115 38 01C 0.33 37 1314 B
112 47 VS2
-0.8 28 1354 B
115 38 02C 0.81 13 1315 B
112 47 VS2 0.88 18 1355 B
115 38 VS4
-0.59 15 1316 B
112 47 VS4 1.05 25 1356 B
115 84 03H
-0.83 14 Page D-17
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1357 B
115 86 03H 0.85 16 1397 B
118 43 VS4 0.95 17 1358 B
115 102 08H 0.81 12 1398 B
118 43 VS6 0
17 1359 B
115 124 05C
-0.91 17 1399 B
118 73 VS6
-0.85 15 1360 B
115 126 03C
-0.92 17 1400 B
118 73 VS7
-0.77 15 1361 B
115 126 03C 0.81 19 1401 B
118 87 VS2 0.99 19 1362 B
116 39 03H 0.93 13 1402 B
118 89 VS2 1.04 27 1363 B
116 43 VS4 0.88 20 1403 B
118 89 VS4 0.77 15 1364 B
116 45 06H 0.97 15 1404 B
118 97 VS2
-0.85 13 1365 B
116 45 VS2 0
16 1405 B
118 101 08C 0.91 11 1366 B
116 45 VS4 0.92 20 1406 B
118 105 VS4
-0.68 15 1367 B
116 47 VS4 0.9 17 1407 B
118 117 04C
-0.19 18 1368 B
116 55 04C 0.81 14 1408 B
118 123 02C 0.74 14 1369 B
116 55 VS2
-0.86 12 1409 B
118 123 04C
-0.95 23 1370 B
116 55 VS4 1
19 1410 B
119 42 02H 0.99 14 1371 B
116 77 VS2 0.73 14 1411 B
119 42 03C 0.4 19 1372 B
116 81 07C
-1 14 1412 B
119 42 04C
-0.28 18 1373 B
116 81 07C
-0.23 11 1413 B
119 42 VS7
-0.74 18 1374 B
116 81 VS7
-0.85 18 1414 B
119 44 01C 0.65 17 1375 B
116 97 04C
-0.3 12 1415 B
119 44 02H 0.85 18 1376 B
116 103 05C 0.91 19 1416 B
119 46 02C 0.81 21 1377 B
116 111 04C
-1.02 19 1417 B
119 72 DBC 0.88 17 1378 B
116 111 05H
-0.78 13 1418 B
119 88 08C
-0.36 10 1379 B
116 115 VS4 0.93 21 1419 B
119 88 08C 0.76 23 1380 B
116 117 03C
-1 12 1420 B
119 104 VS1
-0.65 13 1381 B
116 117 03C
-0.23 16 1421 B
119 112 03C
-0.94 12 1382 B
116 125 03C 0.81 36 1422 B
119 112 03C 0.84 16 1383 B
116 125 04C
-0.07 16 1423 B
119 112 04C 0.84 16 1384 B
116 125 04C 0.74 17 1424 B
120 43 01C
-1.03 19 1385 B
117 40 01C
-0.93 11 1425 B
120 45 02C 0.74 15 1386 B
117 40 02C
-1.05 21 1426 B
120 47 03C
-1.03 10 1387 B
117 40 02C
-0.26 12 1427 B
120 47 03C 0.77 24 1388 B
117 40 02C 0.88 15 1428 B
120 49 03C
-0.95 13 1389 B
117 40 03C
-0.93 20 1429 B
120 49 VS2 0.09 21 1390 B
117 40 04C
-0.21 18 1430 B
120 61 08C 0.73 15 1391 B
117 40 05C 0.7 11 1431 B
120 103 07H 0.85 21 1392 B
117 68 05H 1.01 14 1432 B
120 105 VS2
-0.79 23 1393 B
i 17 90 08C 0.92 19 1433 B
120 113 VS2
-0.94 19 1394 B
117 112 04H 1.06 19 1434 B
120 113 VS2 0.82 17 1395 B
118 41 02H 0.95 13 1435 B
120 115 03C 0.79 22 1396 B
118 41 03C
-0.32 12 1436 B
121 44 01H 0.95 17 Page D-18
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1437 B
121 114 VS4
-0.77 15 1477 B
125 104 07C
-0.23 24 1438 B
121 118 02C 0.74 18 1478 B
125 104 07H 0.92 23 1439 B
122 71 05H 0.92 14 1479 B
125 112 02C 0.85 24 1440 B
122 71 VS2
-0.74 15 1480 B
125 114 03C 0.74 19 1441 B
123 52 02C 0.75 18 1481 B
125 116 02H 0.93 23 1442 B
123 72 VS4
-0.79 15 1482 B
125 116 03H 0.89 18 1443 B
123 72 VS7 1
15 1483 B
125 116 VS4
-0.79 21 1444 B
123 116 03C 0.77 12 1484 B
126 55 02C 0.77 15 1445 B
123 116 04C 0.74 13 1485 B
126 55 06H 0.87 13 1446 B
123 116 05C
-1.02 18 1486 B
126 61 VS1 0.93 15 1447 B
123 116 VS6
-0.66 37 1487 B
126 81 VS4
-0.7 14 1448 B
123 118 VS6
-0.83 32 1488 B
126 83 VS1
-0.23 19 1449 B
123 118 VS7
-0.98 19 1489 B
126 91 VS2 0
23 1450 B
124 47 01C
-0.16 13 1490 B
126 95 VS4
-0.77 25 1451 B
124 47 03C 0.75 11 1491 B
126 95 VS6 1.1 19 1452 B
124 49 02C
-0.98 18 1492 B
126 99 08C 0.75 16 1453 B
124 51 VS4 0.68 15 1493 B
126 103 VS4 0.9 15 1454 B
124 55 05H 0
13 1494 B
126 109 04H 1.03 16 1455 B
124 57 VS?
-0.8 16 1495 B
126 115 02C 0.02 14 1456 B
124 73 VS2 0.81 11 1496 B
126 115 02C 0.95 24 1457 B
124 85 VS2 0.2 16 1497 B
127 52 01H
-0.02 12 1458 B
124 85 VS2 0.74 13 1498 B
127 54 01H
-0.84 20 1459 B
124 85 VS4
-0.67 20 1499 B
127 92 08C
-0.25 18 1460 B
124 87 VS4 0.8 17 1500 B
127 92 VS6
-0.87 13 1461 B
124 93 VS2
-0.73 21 1501 B
127 102 07C
-0.26 13 1462 B
124 93 VS2 0.02 33 1502 B
127 104 06C 0.79 12 1463 B
124 93 VS4
-0.94 14 1503 B
127 106 07C
-0.26 22 1464 B
124 95 VS2 0
17 1504 B
127 112 02C 0.71 21 1465 B
124 95 VS4
-0.96 18 1505 B
127 114 01H
-0.84 20 1466 B
124 95 VS4 0.85 23 1506 B
127 114 02C 0.85 17 1467 B
124 97 06C 0.84 19 1507 B
128 53 01H
-0.16 18 1468 B
124 105 06C 0.82 16 1508 B
128 55 01C
-0.26 18 1469 B
124 117 04C 0.75 22 1509 B
128 73 VS1 0.11 24 1470 B
124 117 VS7
-0.14 23 1510 B
128 73 VS4 1.01 15 1471 B
125 48 VS4 0.9 16 1511 B
128 99 07C 0.77 12 1472 B
125 48 VS6 0.91 16 1512 B
128 101 05C 0.71 23 1473 B
125 78 03H
-0.78 12 1513 B
128 113 02C
-0.88 30 1474 B
125 94 VS2
-0.63 24 1514 B
129 56 01C 0.77 19 1475 B
125 94 VS2 0
21 1515 B
129 56 01H 0.94 21 1476 B
125 100 08C 0.65 15 1516 B
129 64 VS7
-0.6 16 Page D-19
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1517 s
129 84 06H 0.88 23 1557 s
133 76 07C 0.81 13 1518 s
129 102 08C
-0.87 24 1558 s
133 100 VS7 0
21 1519 s
129 102 08C 0.1 13 1559 s
133 102 07C
-1 23 1520 s
129 104 07C
-0.26 18 1560 s
133 102 VS7
-0.81 18 1521 s
129 106 08C 0.93 26 1561 s
133 104 DSC 1.4 15 1522 s
129 110 02C 0.76 20 1562 s
133 104 VS7 0.92 24 1523 s
130 55 01H 0.99 17 1563 s
134 63 07C 0.69 19 1524 s
130 55 02C 0.86 15 1564 B
134 63 DSH
-1.51 14 1525 s
130 65 VS4 0.7 14 1565 s
134 65 02H 0.91 21 1526 s
130 65 VS7 1.1 25 1566 B
134 69 04H 0.92 18 1527 s
130 67 05H 0.95 14 1567 B
134 69 VS7 0.99 27 1528 s
130 79 VS2
-0.86 12 1568 s
134 95 DBC 1.52 18 1529 s
130 91 DSC 1.35 25 1569 s
134 97 VS6
-0.8 11 1530 s
131 58 01C 0.73 31 1570 B
134 97 VS6 0.9 15 1531 s
131 64 VS7 1.14 26 1571 B
134 99 VS6
-0.75 17 1532 s
131 70 03C 0.86 15 1572 s
134 99 VS6 0.97 27 1533 s
131 78 VS6
-0.8 15 1573 B
134 101 VS7 0.99 26 1534 s
131 82 08H
-0.87 17 1574 B
135 68 VS7 1.1 20 1535 s
131 96 04C 0.79 20 1575 s
135 72 VS7
-0.84 19 1536 s
131 98 DSC 1.59 15 1576 s
135 76 06H 0.9 12 1537 s
131 98 VS6 1
31 1577 s
135 76 08C
-1.07 23 1538 s
131 98 VS7 0.83 26 1578 s
135 76 08C 0.74 16 1539 s
131 102 04C 0.82 13 1579 s
135 76 VS7
-0.82 19 1540 s
131 102 05C 0.77 15 1580 s
135 80 07H
-0.76 13 1541 s
131 102 06C
-1.04 20 1581 s
135 82 VS7
-0.84 20 1542 s
131 104 DSC 1.69 16 1582 s
135 82 VS7 0.95 26 1543 s
131 104 VS7 0.96 27 1583 s
135 90 VS7 0.73 27 1544 s
131 108 07H
-0.93 17 1584 s
135 94 DSC 1.53 24 1545 s
132 61 01H 0.89 16 1585 s
135 96 04C 0.77 13 1546 s
132 61 02H
-0.84 20 1586 s
135 98 VS6
-0.65 17 1547 s
132 81 05H 0.94 16 1587 B
136 69 DBC 1.57 19 1548 s
132 91 DSC 1.51 11 1588 B
136 77 03H 0.81 14 1549 s
132 97 VS1 0.93 11 1589 B
136 87 08C
-1.12 15 1550 s
132 97 VS2
-0.66 18 1590 s
136 91 DSC 1.68 21 1551 s
132 97 VS4
-0.83 16 1591 B
136 95 03C 0.74 19 1552 s
132 97 VS7 0.99 28 1592 B
136 97 03C 0.81 17 1553 B
132 101 06C
-0.23 15 1593 B
136 97 07C 0.6 17 1554 s
132 101 06C 0.79 18 1594 s
136 97 08C
-1.18 19 1555 s
132 107 02C
-0.9 30 1595 s
136 97 08C 0
16 1556 s
133 74 03H 0.83 15 1596 s
136 97 VS7
-0.74 31 Page D-20
framatome Document No.: 51-9321268-000 Palisades 1 R27 2020 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1597 B
136 97 VS?
0.96 18 1615 B
138 79 VS2 0.77 25 1598 B
137 74 06H 0.85 16 1616 B
138 79 VS4 0.84 23 1599 B
137 80 08H 0.84 19 1617 B
138 79 VS6
-0.84 22 1600 B
137 90 DSC 1.48 16 1618 B
138 79 VS6 0.95 22 1601 B
137 90 DBH 2.04 24 1619 B
138 81 08C
-1.17 16 1602 B
137 90 VS4 0.23 16 1620 B
138 81 VS4
-0.84 23 1603 B
137 90 VS4 0.82 14 1621 B
138 85 08H 0.85 15 1604 B
137 90 VS6
-0.56 19 1622 B
138 85 DBH 2.04 28 1605 B
137 90 VS?
-0.88 20 1623 B
138 87 VS1
-0.84 20 1606 B
137 90 VS?
0.91 21 1624 B
138 87 VS1 0.97 14 1607 B
137 92 07C 0.07 15 1625 B
138 87 VS4
-0.64 19 1608 B
137 92 08C
-1 23 1626 B
138 89 0?C 0.75 16 1609 B
137 92 VS6
-0.74 18 1627 B
138 89 VS4
-0.64 21 1610 B
137 92 VS?
-0.58 24 1628 B
138 89 VS6 0.93 16 1611 B
138 77 02H 0.94 21 1629 B
138 89 VS?
-0.84 18 1612 B
138 77 VS4 0.86 22 1630 B
138 89 VS?
0.96 35 1613 B
138 79 03H 0.92 16 1631 B
138 91 DBH 1.93 21 1614 B
138 79 VS1
-0.7 30 Page D-21