Letter Sequence Other |
|---|
|
|
MONTHYEARML20344A3862020-12-0707 December 2020 Westinghouse, Submittal of WCAP-18124-NP-A Revision 0 Supplement 1-P and WCAP-18124-NP-A Revision 0 Supplement 1-NP, Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Materials, Revision 0 Project stage: Request ML20344A3882020-12-31031 December 2020 WCAP-18124-NP-A, Revision 0, Supplement 1-NP, Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Materials Project stage: Request ML21015A4212021-01-21021 January 2021 Prop Withholding Determination Form Westinghouse Topical Report WCAP-18124-NP-A, Revision 0, Supplement 1-P and WCAP-18124-NP-A, Revision 0, Supplement 1-NP Project stage: Other ML21015A4232021-01-21021 January 2021 Completeness Determination Form Westinghouse Topical Report WCAP-18124-NP-A, Revision 0, Supplement 1-P and WCAP-18124-NP-A, Revision 0, Supplement 1-NP Project stage: Other ML21165A1792021-06-21021 June 2021 Email Request for Additional Information Westinghouse Topical Report WCAP-18124-NP-A, Rev 0, Suppl 1-P and WCAP-18124-NP-A, Rev 0, Suppl 1-NP, Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Project stage: RAI ML21228A0772021-08-11011 August 2021 Enclosure 3: Westinghouse Responses to NRC Request for Additional Information on WCAP-18124-NP-A, Revision 0, Supplement 1-P/NP, Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Materials (Non-Proprietary) Project stage: Supplement ML21228A0762021-08-11011 August 2021 Submittal of Westinghouse Responses to NRC Request for Additional Information on WCAP-18124-NP-A, Revision 0, Supplement 1-P/NP, Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Materials, EPID: L-2020-TOP Project stage: Supplement ML22014A1052022-02-15015 February 2022 Transmittal Email for Draft SE for Westinghouse Topical Report WCAP-18124-NP-A, Rev. 0, Supplement 1 P and WCAP-18124-NP-A, Rev. 0, Suppl. 1-NP, Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Materials Project stage: Draft Approval ML22091A2312022-04-13013 April 2022 NRC 897 Form Prop Withholding Determination Form Westinghouse Topical Report WCAP-18124-NP-A, Rev. 0, Suppl. 1-P and WCAP-18124-NP-A, Revision 0, Suppl. 1-NP, Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltli Project stage: Other ML22200A0292022-07-21021 July 2022 NRC 896 Form for the U.S. Nuclear Regulatory Commission Staff -A Verification of the Topical Report WCAP-18124-NP-A, Revision 0, Supplement 1-P/NP-A Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Materia Project stage: Other ML22203A0242022-07-25025 July 2022 Withholding Determination NRC 897 Form Westinghouse Electric Company Topical Report WCAP-18124-NP-A, Revision 0, Supplement 1-P/NP-A Fluence Determination with RAPTOR-M3G and Ferret - Supplement for Extended Beltline Materials Project stage: Other 2021-08-11
[Table View] |
Completeness Determination Form Westinghouse Topical Report WCAP-18124-NP-A, Revision 0, Supplement 1-P and WCAP-18124-NP-A, Revision 0, Supplement 1-NP| ML21015A423 |
| Person / Time |
|---|
| Site: |
Westinghouse |
|---|
| Issue date: |
01/21/2021 |
|---|
| From: |
Kevin Heller, Benjamin Parks, Benjamin Wise Licensing Processes Branch, NRC/NRR/DSS/SFNB |
|---|
| To: |
|
|---|
| Lenning K -NRR/DORL 301-415-3151 |
| Shared Package |
|---|
| ML21015A323 |
List: |
|---|
| References |
|---|
| EPID L-2020-TOP-0063, WCAP-18124-NP-A, Rev 0, Supp 1-P |
| Download: ML21015A423 (1) |
|
Text
NRC FORM 898 (11-2020)
Topical Report Completeness Determination U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 898 (11-2020)
Page 1 of 1 Topical Report Information Report Number:
WCAP-18124-NP-A Rev. 0 Supplement 1-P
Title:
Fluence Determination with RAPTOR-M3G and FERRET - Supplement for Extended Beltline Materials ADAMS Accession Number:
ML20344A386 EPID:
L-2020-TOP-0063 Docket Number:
99902038 Review Information Office/Division/
Branch:
NRR/DORL/LLPB, NRR/DSS/SFNB Project Manager:
Ekaterina Lenning, NRR/DORL/LLPB Reviewers:
Benjamin Parks, NRR/DSS/SFNB Brandon Wise, NRR/DSS/SFNB Kevin Heller, NRR/DSS/SFNB Review Type:
Standard
Compressed ADAMS Accession Numbers (Top row is for transmittal of this form)
Package: ML21015A323 E-mail: ML21015A369 This Form: ML21015A423 Withholding Determination: ML21015A421 Fee Waiver: ML Topical Reports Accepted for Review
The NRC staff has performed an acceptance review of the subject topical report. We have found that the material presented is sufficient to begin our review. The dates below are based on current resources, if they change the NRC staff will contact you.
Information for Topical Reports That Are Found Acceptable for Review Issue Dates For Requests for Additional Information: 06/25/2021 Issue Dates For Draft Safety Evaluation: 01/10/2022 Review hours total includes project management and contractor time:
580 Topical Reports Not Acceptable for Review Based on its review of the information provided, the NRC staff cannot find sufficient details in the submittal to allow the staff to evaluate the proposed topical report.
[Only for Use with Topical Reports in Standard Review Process] Although the NRC staff has found the current topical report is not sufficiently detailed to begin our review, the sponsor can supplement the submittal with additional information. The additional information should be submitted within 60 days the date of this form.
Basis for Nonacceptance:
Additional Information Needed:
Approvals Technical Branch Chief Projects Branch Chief Robert Lukes Digitally signed by Robert Lukes Date: 2021.01.21 12:08:50 -05'00' Dennis C. Morey Digitally signed by Dennis C. Morey Date: 2021.01.21 17:43:00 -05'00'