5 to Updated Final Safety Analysis Report, Chapter 7, Drawing 102792, Rev. 5, Sheet 1, Electrical Logic Diagram Component Cooling Water Pumps
ML20268A810
Person / Time
Site: Diablo Canyon  
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268A810 (1)


Text

CX) 0 N

E D

C

~ B I

C W

Q) 0 u

00 0 C Q) 0 Q)+-

1 u o

.o lo NI s::;r en -

Vl r--

I z NNN Oo, oo r-- L II N Q) 0:::: 0 U) w -

=:J I-II VlZO

<( C) <(

o::::ou A

REF 5, 6 & 7 HOR A HOR B 2

D TRANSFER TO DIESEL BLOCK AUTO START COMP COOL WTR LOW PRESS SIS 3

ACS/START A43/MAN 4

REF 5, A >-S_I_S_A_U_TO ____.,..

6 & 7 START SIGNAL REF 5, B 4KV AUTO TRANSFER 6 & 7 SIGNAL (NO SISl 43/TS/CONTROL ROOM REF 5, F >-S_I_S_A_U_TO ____ _

6 & 7 START SIGNAL REF 5, G 4KV AUTO TRANSFER 6 & 7 SIGNAL (NO S!Sl START C.C.W. PP CS/ON C.C.W. PP RUNNING CS/AUTO 5

6 7

CS/CLOSE (SWGR)

BREAKER IN TEST POSITION LUBE OIL PRESS 6CS/START ALARM 6CS/NEUT 414f-----------'

'-----t----+-------.1--....:...J 643/AUTO ALARM 6CS/S TOP 212 t------------~

OVERCURRENT A43/MAN ACS/STOP 3;3 f------------------.i/

REF 5, c TRANSFER TO DIESEL 6 & 7 LOAD SHED CS/TRIP CSWGRl NO. 21 52-2F-44 NO. 22 52-2G-41 NO. 23 52-2H-35 8

9 10 NOTES 43/TS - TRANSFER SWITCH TRANSFERS CONTROL FROM MAIN CONTROL BOARD TO HOT SHUTDOWN PANEL

<LOCATED AT SWITCHGEAR).

43 - MODE SELECTOR SWITCH FOR SELECTING II AUTO" OR II MANUAL II MODE ( LOCATED AT HOT SHUTDOWN PANEL & MAIN CONTROL ROOM).

6 -

REMOTE CONTROL SWITCH LOCATED AT HOT SHUTDOWN PANEL.

A - REMOTE CONTROL SWITCH LOCATED IN MAIN CONTROL ROOM.

LOW PRESSURE SETPOINT ONLY REACHED WITH LOSS OF ALL RUNNING PUMPS.

CLOSE 52 TRIP a 0 52HFl2 NO. 21 52HGl2 NO. 22 b

52HHl2 NO. 23 REFERENCES DWG NO.

I. LOGIC DIAG SYMBOLS _________ 19425

2. SCHEMATIC DIAG COMP CLG WTR _____ 44131 I
3. SLM&R DIAG 4KV BUS F ________ 44 I 229
4. SLM&R DIAG 4KV BUS G & H ______ 44 I 230
5. LOGIC DIAG 4KV BUS F AUTO TRANSFER __ 441286
6. LOGIC DIAG 4KV BUS G AUTO TRANSFER __ 441297
7. LOGIC DIAG 4KV BUSH AUTO TRANSFER __ 441337 L.O. LOW PRESS (3 MIN)

COMPONENT COOLING PUMP AUXILIARY LUBE OIL PUMP OVERCURRENT 2;2,______ __

1--------l~....!:::...J ON

--0 DATE REVISION DESCRIPTION 06-18-2018 Revised Pe, DDN-2*1867 D. D.

ZNS4 R. E.

FXC2 I. V.

NIA P. E.

NIA INPG I Size OFF NUCLEAR SAFETY RELATED UNIT 2 ELECTRICAL LOGIC DIAGRAM COMPONENT COOLING WATER PUMPS DIABLO CANYON POWER PLANT PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORNIA KEY DWG. SECTION 3

DWG SCALE:

B I L L OF MAT L :

SUPSDS:

SUPSD BY:

DRAWING SHEET PAGE REV 102792 0