TABLE 1A SEMIANNUAL SUMMATION OF GASEOUS RELEASES ALL AIRBORNE EFFLUENTS QUARTERS l AND 2,1996 l

r FIRST SECOND ESTTOTAL TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a)

A. FISSION AND ACTIVATION GASES

1. TOTAL RELEASE CURIES 1.57E+01 2.56E+0i 20
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 2.00E+00 3.25E+00
3. PERCENT OF TECH SPEC LIMIT N/A N/A D. RADIOIODINES
1. TOTAL IODINE-131 CURIES 7.25E-05 0.00E+00 23
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 9.22E-06 0.00E+00
3. PERCENT OF TECH SPEC LIMIT N/A N/A C. PARTICULATE
1. PARTICULATE (HALF-LIVES > 8 DAYS)

CURIES 0.00E+00 1.13E-07 30

2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 0.00E+00 1.44E-08
3. PERCENT OF TECH SPEC LIMIT G

N/A N/A

4. GROSS ALPHA RADIOACTIVITY CURIES 5.92E-07 1.98E-07 D. TRITIUM
1. TOTAL RELEASE CURIES 3.34E+01 1.31 E+01 14
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 4.25E+00 1.66E+00
3. PERCENT OF TECH SPEC LIMIT N/A N/A (a) Safety Analysis Calculation 87-063-00, January 6,1988

, PageIof2 9005L90350 980501 PDR ADOCK 050004 3 R

~

TABLE 1 A (continued)

SEMIANNUAL SUMMATION OF GASEOUS RELEASES ALL AIRBORNE EFFLUENTS QUARTERS 3 AND 4,1996 THIRD FOURTH EST TOTAL TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a)

A. FISSION AND /.Ci1VATION GASES

1. TOTAL RELEASE CURIES 7.92E+00 8.99E+01 20
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 9.96E-01 1.13E+01
3. PERCENT OF TECH SPEC LIMIT N/A N/A B. RADIO!ODINES
1. TOTAL IODINE-131 CURIES 0.00E+00 7.46E-06 23
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 0.005:00 9.38E-07
3. PERCENT OF TECH SPEC LIMIT

'7e N/A N/A C. PARTICULATE

1. PARTICULATE (HALF-LIVES > 8 DAYS)

CURIES 1,71 E-07 4.88E-06 30

2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 2.15E-08 6.14E-07
3. PERCENT OF TECH SPEC LIMIT

'7c N/A N/A I

4. GROSS ALPHA RADIOACTIVITY CURIES 2.56E-07 1.07E-06 D. TRITIUM
1. TOTAL RELEASE CURIES 1.12E+0!

2.98E+01 14

2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 1.41E+00 3.75E+00
3. PERCENT OF TECH SPEC LIMIT 91 N/A N/A (a) Safety Analysis Calculation 87-063-00. January 6.1988

)

I

)

l l

Page 2 of 2 k

TABLEIB SEMIANNUAL AIRBORNE CONTINUOUS AND BATCH RELEASES GROUND LEVEL RELEASES FISSION GASES, IODINES, AND PARTICULATE QUARTERS I AND 2,1996 CONTINUOUS RELEASES BATCH RELEASES FIRST SECOND FIRST SECOND NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER

1. FISSION GASES AR-41 CURIES 0.00E+00 0.00E+00 1.49E-01 5.40E-02 XE-133 CURIES 1.47E+01 2.10E+01 6.67E-02 4.89E-02 XE-135 CURIES 5.88E-01 1.24E+00 1.08E-02 1.43E-03 XE-135M CURIES 0.00E+00 0.00E+00 5.32E-02 1.13E-04 XE-131M CURIES 0.00E+00 3.20E+00 1.15E-07 1.23E-03 KR-85 CURIES 0.00E+00 0.00E+00 1.20E-01 0.00E+00 KR-87 CURIES 0.00E+00 0.00E+00 0.00E+00 7.21E-05 XE-133M CURIES 0.00E+00 0.00E+00 0.00E+00 2.60E-04 KR-85M CURIES 0.00E+00 0.00E+00 0.00E+00 7.90E-06 KR-88 CURIES 0.00E+00 0.00E+00 0.00E+00 2.i1E-05 TOTAL FOR PERIOD CURIES 1.53E+01 2.55E+01 4.00E-01 1.06E-01
2. IODINES I-131 CURIES 0.00E+00 0.00E+00 7.25E-05 0.00E+00 1-132 CURIES 0.00E+00 0.00E+00 2.43E-07 0.00E+00 1-133 CURIES 0.00E+00 0.00E+00 1.38E-04 0.00E+00 1-134 CURIES 0.00E+00 0.00E+00 2.96E-08 0.00Et00 1-135 CURIES 0.00E+00 0.00E+00 9.56E-12 0.00E+00 TOTAL FOR PERIOD CURIES 0.00E+00 0.00E+00 2.I1E-04 0.00E+00
3. PARTICULATE CO-60 CURIES 0.00E+00 1.13E 07 0.00E+00 0.00E+00 j

ALPHA CURIES 5.92E-07 1.98E-07 0.00E+00 0.00E+00 I

i TOTAL FOR PERIOD CURIES 5.92E-07 3.I1E-07 0.00E+00 0.00E+00

4. TRITIUM H3 CURIES 7.82E+00 1.27E+0!

2.56E+01 3.24E-01 Page I of 2 l

]

TABLE IB (continued)

SEMIANNUAL AIRBORNE CONTINUOUS AND BATCH RELEASES GROUND LEVEL RELEASES FISSION GASES, IODINES, AND PARTICULA' ITIS QUARTERS 3 AND 4,1996 CONTINUOUS RELEASES BATCH RELEASES THIRD FOURTH THIRD FOURTH NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER

1. FISSION GASES AR-41 CURIES 1.25E+00 5.43E-01 4.71E-01 5.26E-01 XE-133 CURIES 5.15E+00 2.20E+01 2.79E-01 6.35E+0!

XE 135 CURIES 6.68E-01 2.03E+00 1.31E-02 9.47E-03 XE-135M CURIES 0.00E+00 2.63E-02 2.02E-04 0.00E+00 XE-131M CURIES 0.00E+00 0.00E+00 1.88E-03 3.48E-02 KR-85 CURIES 0.00E+00 0.00E+00 8.68E-02 6.08E-02 KR-87 CURIES 0.00E+00 2.63E-03 1.86E-05 0.00E+00 XE-133M CURIES 0.00E+00 0.00E+00 4.27E-04 6.97E-01 KR-85M CURIES 0.00E+00 3.64E-02 0.00E+00 0.00E+00 ER-88 CURIES 0.00E+00 3.50E-01 1.27E-03 0.00E+00 XE-138 CURIES 0.00E+00 0.00E+00 3.42E-04 2.96E-04 TOTAL FOR PERIOD CURIES 7.07E+00 2.50E+01 8.54E-01 6.49E+0i

2. IODINES 1 131 CURIES 0.00E+00 7.46E-06 0.00E+00 0.00E+00 1-132 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1-133 CURIES 0.00E+00 1.24E-05 0.00E+00 0 00E+00 1-134 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1-135 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD CURIES 0.00E+00 1.98E-05 0.00E+00 0.00E+(0
3. PARTICULATE CO-60 CURIES 1.71 E-07 0.00E+00 0.00E+00 0.00E+00 CE-141 CURIES 0.00E+00 7.37E-07 0.00E+00 0.00E+00 CO-58 CURIES 0.00E+00 3.19E-06 0.00E+00 0.00E+00 CR-51 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NB-95 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 CE-144 CURIES 0.00E+00 9.53E-07 0.00E+00 0.00E+00 ALPHA CURIES 2.56E-07 1.07E-06 0.00E+00 0.00E+00 TOTAL FOR PERIOD CURIES 4.27E-07 5.95E-06 0.00E+00 0.00E+00
4. TRITIUM i

H-3 CURIES 1.03E+01 2.84 E+01 9.36E 01 1.37E+00 Page 2 of 2 e

1 TABLE 2A SEMIANNUAL SUMM ATION OF LIQUID RELEASES ALL LIQUID EFFLUENTS QUARTERS I AND 2.1996 I

l FIRST SECOND EST TOTAL TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a) l 1

A. FISSION AND ACTIVATION PRODUCTS

1. TOTAL RELEASE [NOT INCLUDING TRITIUM, GASES, ALPIIA]

CURIES 7 93E-04 7.66E-04 20

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 2.07E-09 1.75E-09
3. PERCENT OF APPLICABLE LIMIT N/A N/A l

B. TRITIUM

1. TOTAL RELEASE CURIES 3.07E+02 4.05E+02 14 I
2. AVERAGE DILUTED CONCENTRATION I

DURING PERIOD uCi/ML 8.02E-04 9.26E 04 i

3. PERCENT OF APPLICABLE LIMIT N/A N/A C. DISSOLVED AND ENTRAINED GASES I
1. TOTAL RELEASE CURIES 3.88E-03 6.91 E-03 27
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.01 E-08 I58E-08 i

D. GROSS ALPHA RADIOACTIVITY

1. TOTAL RELEASE CURIES 5.71E-04 1.26E-03 29 E. WASTE VOLUME RELEASED (PRE-DILUTION)

GAL 4.96E+06 6.12E+06 10 F. VOLUME OF DILUTION WATER USED GAL 9.64E+07 1.09E+0S 10 (a) Safety Analysis Calculation 87-063-00,.lanuary 6,1988 Page1of2 L._______._________.

)

l l

TABLE 2A (continued)

SEM! ANNUAL SUMMATION OF 1.lQUID RELEASES ALL LIQUID EFFLUENTS QUARTERS 3 AND 4,1996 THIRD FOURTH EST TOTAL TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a)

A. FISSION AND ACTIVATION PRODUCTS

1. TOTAL RELEASE [NOT INCLUDING TRITIUM, GASES, ALPHA]

CURIES 3.65E-02 7.58E-01 20

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML

' 97E-08 1.87E 06

3. PERCENT OF APPLICABLE LIMIT N/A B. TRITIUM
1. TOTAL RELEASE CURIES 3.42E+02 1.15E+02 14
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 6.53E-04 2.84E-04
3. PERCENT OF APPLICABLE LIMIT N/A N/A C. DISSOLVED AND ENTRAINED GASES
1. TOTAL RELEASE CURIES 1.2 ] E-02 1.33E-02 27
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 2.32E-08 3.27E-08 D. GROSS ALPHA RADIOACTIVITY
1. TOTAL RELEASE CURIES 8.51E-03 1.4 l E-02 29 E. WASTE VOLUME RELEASED (PRE-DILUTION)

GAL 6.30E+06 4.93E+06 10 F. VOLUME OF DILUTION WATER USED GAL 1.32E+08 1.02E+08 10 (a) Safety Analysis Calculation 87-063-00, January 6,1988 Page 2 of 2

TABLE 2B SEMIANNUAL LIQUID CONTINUOUS AND BATCH RELEASES TOTALS FOR EACH NUCLIDE RELEASED QUARTERS 1 AND 2,1996 CONTINUOUS RELEASES -

B ATCH RELEASES FIRST SECOND FIRST SECOND NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER

1. ALL NUCLIDES ALPHA CURIES 0.00E+00 0.00E+00 5.7 ] E-04 1.26E-03 CO-60 CURIES 0.00E+00 0.00E+00 3.99E.04 6.77E-04 H-3 CURIES 0.00E+00 0.00E+00 3.07E+02 4.05E+02 CE-144 CURIES 0.00E+00 0.00E+00 3.81E-05 0.00E+00 PR-144 CURIES 0.00E+00 0.00E+00 3.81E-05 0.00E+00 CO-58 CURIES 0.00E+00 0.00E+00 2.64E-04 4.46E-05 CS-137 CURIES 0.00E+00 0.00E+00 4.09E-05 2.52E-06 MN-54 CURIES 0.00E+00 0.00E+00 5.82E-06 1.40E-05 XE-133 CURIES 0.00E+00 0.00E+00 3.75E-03 6.55E-03 XE-133M CURIES 0.00E+00 0.00E+00 4.38E-05 0.00E+00 XE-135 CURIES 0.00E+00 0.00E+00 8.03E-05 5.83E-05 HF-181 CURIES 0.00E+00 0.00E+00 9.12E-07 0.00E+00 SB-125 CURIES 0.00E+00 0.00E+00 5.94E-06 7.37E-06 XE-13 ]M CURIES 0.00E+00 0.00E+00 0.00E+00 2.93E-04 CE-141 CURIES 0.00E+00 0.00E+00 0.00E+00 4.40E-06 CO-57 CURIES 0.00E+00 0.00E+00 0.00E+00 1.73E-06 KR-85M CURIES 0.00E+00 0.00E+00 0.00E+00 4.43E-06 CR-51 CURIES 0.00E+00 0.00E+00 0.00E+00 1.39E-05 l

TOTALS FOR PERIOD CURIES 0.00E+00 0.00E+00 3.07E+02 4.05E+02 i

i l

1 i

i i

i Page 1 of 2

__-__a

TABLE 2B (continued)

SEMIANNUAL LIQUID CONTINUOUS AND B ATCH RELEASES TOTALS FOR EACH NUCLIDE RELEASED QUARTERS 3 AND 4.1996 CONTINUOUS RELEASES BATCH RELEASES THIRD FOURTH THIRD FOURTH NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER

1. ALL NUCt UES ALPHA CURIES 0.00E+00 0.00E+00 8.51E-03 1.41 E-02 CO-60 CURIES 0.00E+00 0.00E+00 1.56E-02 2.29E-02 H-3 CURIES 0.00E+00 0.00E+00 3.42E+02 1.15E+02 CE-144 CURIES 0.00E+00 0.00E+00 1.05E-04 0.00E+00 PR-144 CURIES 0.00E+00 0.00E+00 1.05E-04 0.00E+00 CO-58 CURIES 0.00E+00 0.00E+00 5.18E-03 6.00E-01 CS-137 CURIES 0.00E+00 0.00E+00 4.86E-04 4.03E-04 M N-54 CURIES

'0.00E+00 0.00E+00 2.09E-03 6.56E-03 XE-133 CURIES 0.00E+00 0.00E+00 1.09E-02 1.19E-02 XE-133M CURIES 0.00E+00 0.00E+00 4.55E 05 4.65E-05 XE-135 CURIES 0.00E+00 0.00E+00 2.22E-04 1.49E-05 SB-125 CURIES 0.00E+00 0.00E+00 7.64E-03 1.85E-02 XE-131M CURIES 0.00E+00 0.00E+00 1.56E-04 1.28E-03 CO-57 CURIES 0.00E+00 0.00E+00 1.17E-04 1.19E-03 KR-85M CURIES 0.00E+00 0.00E+00 0.00E+00 9.43E< 06 CR-51 CURIES 0.00E+00 0.00E+00 1.45E-04 4.40E-02 SR-90 CURIES 0.00E+00 0.00E+00 4.05E-04 9.88E-04 CS-134 CURIES 0.00E+00 0.00E+00 4.98E-05 2.71E-05 NB-95 CURIES 0.00E4)0 0.00E+00 2.86E-06 8.03E-03 RU-106 CURIES 0.00E+00 0.00E+00 4.72E-04 9.96E-05 I-131 CURIES 0.00E+00 0.00E+00 3.59E-03 1.79E-02 I-133 CUR 1ES 0.00E+00 0.00E+00 3.99E-04 1.01E-03 TC-99M CURIES 0.00E+00 0.00E+00 5.66E-05 4.36E-04 AG-110M CURIES 0.00E+00 0.00E+00 1.79E-05 7.77E-05 BE-7 CURIES 0.00E+00 0.00E+00 3.79E-07 0.00E+00 ZR-95 CURIES 0.00E+00 0.00E+00 3.10E-05 6.26E-03 AM 241 CURIES 0.00E+00 0.00E+00 2.03E-06 0.00E+00 CM-243 CURIES 0.00E+00 0.00E+00 2.38E-06 0.00E+00 PU-241 CURIES 0.00E+00 0.00E+00 7.87E-04 6.71 E-04 FE 55 CURIES 0.00E+00 0.00E+00 0.00E+00 2.56E-02 NP-237 CURIES 0.00E+00 0.00E+00 0.00E+00 5.03E-06 PU-238 CURIES 0.00E+00 0.00E+00 0.00E+00 5.03E-06 LA-140 CURIES 0.00E+00 0.00E+00 0.00E+00 3.30E-04 M O-99 CURIES 0.00E+00 0.00E+ 00 0.00E+00 1.52E-04 SB-124 CURIES 0.00E+00 0.00E+00 0.00E+00 5.57E-04 I-132 CURIES 0.00E+00 0.00E+00 0.00E+00 1.2 ] E-04 FE-59 CURIES 0.00E+00 0.00E+00 0.00E+00 1.38E-03 EU-154 CURIES 0.00E+00 0.00E+00 0.00E4X) 1.75E-04 RU-103 CURIES 0.00E+00 0.00E+00 0.00E+00 2.09E-04 SN413 CURIES 0.00Ed)0 0.00E400 0.00E+00 2.44E-04 AR-41 CURIES 0.00E+00 0.00E+00 0.00E+00 3.35E-05 TOTALS FOR PERIOD CURIES 0.00E+00 0.00E+00 3.42E+02 1.16E+02 Page 2 of 2

1 TABLE 5 DOSE AT THE SITE BOUNDARY AND TO THE NEAREST RESIDENT FROM GASEOUS EFFLUENTS SITE BOUNDARY NEAREST RESIDENT LOCATION: 1.40 km SSW LOCATION: 1.90 km WSW AGE GROUP: CHILD AGE GROUP: CHILD ORGAN UNITS DOSE

% LIMIT (a)

DOSE

% LIMIT (b)

1. GAMMA AIR DOSE
  • MRAD 2.34E-03 0.02 1.38E-03 N/A
2. BETA AIR DOSE
  • MRAD 4.28E-03 0.02 2.52E-03 N/A
3. WHOLE BODY "*

MREM 2.08E-03 N/A 1.22E-03 N/A

4. SKIN "*

MREM 4.15E-03 N/A 2.44E-03 N/A

5. BONE "

MREM 1.17E-06 N/A 1.68E-05 0.00

6. LIVER **

MREM 2.30E-03 N/A 1.20E-02 0.03

7. TOTAL BODY "

MREM 2.30E-03 N/A 1.20E-02 0.08

8. THYROID "

MREM 2.35E-03 N/A 1.73E-02 0.12

9. KI D N E Y "

MREM 2.30E-03 N/A 1.20E-02 0.08

10. LUNG "

MREM 2.30E-03 N/A 1.20E-02 0.08

11. GI-LLI "

MREM 2.30E-03 N/A 1.20E-02 0.08

  • Dose from Noble Gases only

" Dose from Tritium, Radiciodines, and Particulate only

"* Dose from Noble Gases plus Ground Plane dose (a) Annual dose limits of Offsite Dose Calculation Manual ( APA-ZZ-01003) of 10 mrad gamma air dose and 20 mrad beta air dose.

(b) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-01003) of 15 mrem to any organ from I-131,1-133. H-3 and particulate radionuclides with halDives greater than 8 days.

i I

PageIofI

TABLE 6 DOSE TO THE MEMBER OF THE PUDLIC FROM ACTIVITIES WITillN TIIE SITE BOUNDARY EFFLUENT DIRECT DIRECT TOTAL DOSE WITHIN RADIATION RADIATION DOSE THE SITE FROM THE FROM OUTSIDI FOR THE ORGAN UNITS BOUNDARY UNIT TANKS YEAR

1. SKIN MREM 1.04E-03 N/A N/A 1.04E-03
2. BONE MREM 3.63E-07 8.79E-03 2.10E-03 1.09E-02
3. LIVER MREM 7.34E-04 8.79E-03 2.10E-03 1.16E-02
4. TOTAL BODY MREM 1.25E-03 8.79E-03 2.10E-03 1.21E-02
5. THYROID MREM 7.43E-04 8.79E-03 2.10E-03 1.16E-02
6. KIDNEY MREM 7.34E-04 8.79E-03 2.10E-03 1.16E-02
7. LUNG MREM 7.34E-04 8.79E-03 2.10E-03 1.16E-02
8. GI-LLI MREM 7.34E-04 8.79E-03 2.10E-03 1.16E-02 Page1 ofI

l TABLE 7 TOTAL DOSE DUE TO THE URANIUM FUEL CYCLE (MEMBER OF THE PUBLIC)

DOSE FROM TOTAL DOSE DOSE ATTHE ACTIVITIES TO THE RESIDENCE WITHIN SITE MEMBER OF 1

ORGAN UNITS LOCATION BOUNDARY THE PUBLIC 7r LIMITS *

1. SKIN MREM 1.22E-03 1.04E-03 2 25E-03 0.01

~

2. BONE MREM 3.07E-06 1.09E-02 1.09E-02 0.04 i
3. LIVER MREM 3.44E-03 1.16E-02 1.51 E-02 0.06
4. TOTAL BODY MREM 4.05E-03 1.21 E-02 1.62E-02 0.06
5. THYROID MREM 4.67E-03 1.16E-02 1.63E-02 0.02
6. KIDNEY MREM 3.45E-03 1.16E-02 1.5 IE-02 0.06
7. LUNG MREM 3.44E-03 1.16E-02 1.5]E-02 0.06
8. GI.LLI MREM 3.44E-03 1.16E-02 1.5 ] E-02 0 06
  • Annual dose limits from 40CFR19010(a) of 25 mrem whole body 75 mrem to the thyroid and 25 mrem to any other organ.

l Page 1 of1 I

l a

TABLE 8 i

DOSE DUE TO LIQUID EFFLUENTS (MEMBER OF THE PUBLIC) 1996 ORGAN UNITS DOSE LIMIT

  • 7c LIMIT
1. BONE MREM 1.41 E-02 10.00 1.41E-01
2. LIVER MREM 1.11E-02 10.00 1.11 E-01
3. TOTAL BODY MREM 1.17E-02 3.00 3.89E-01
4. THYRO!D MREM 2.14E-02 10.00 2.14E-01
5. KIDNEY MREM 5.61E-03 10.00 5.61 E. 02
6. LUNG MREM 3.98E-03 10.00 3.98E-02
7. GI-LLI MREM 1.67E-01 10.00 1.67E+00
  • Annual dose limits of APA-ZZ-01003, Section 9.4.1.1.

PageI of1