TABLElA SEMIANNUAL SUMM ATION OF GASEOUS RELEASES ALL AIRBORNE EFFLUENTS QUARTERS 1 AND 2,1995 FIRST SECOND EST TOTAL TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a)

A. FISSION AND ACTIVATION GASES

1. TOTAL RELEASE CURIES 3.90E+01 2.66E+00 20
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 5.01E+00 3.39E-01
3. PERCENT OF TECH SPEC LIMIT N/A N/A B. RADIOIODINES
1. TOTAL IODINE-131 CURIES 2.05E-M 3.89E-05 23
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 2.64E-07 4.95E-06
3. PERCENT OF TECH SPEC LIMIT N/A N/A C. PARTICULATE
1. PARTICULATE (HALF-LIVES > 8 DAYS)

CURIES 1.25E-05 1.52E-03 30

2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 1.16E-06 1.93E-04
3. PERCENT OF TECH SPEC LIMIT N/A N/A
4. GROSS ALPHA RADIOACTIVITY CURIES 1.89E-07 2.25E-07 D. TRITIUM
1. TOTAL RELEASE CURIES 9.41E+00 2.74E+01 14
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 1.21E+00 3.48E+00 i
3. PERCENT OF TECH SPEC LIMIT N/A N/A 1

(a) Safety Analysis Calculation 87-063-00, January 6,1988 i

I l

l t

l 1

9905190346 990501 PDR ADOCK 05000483 R

pn

_ _ _ _ _ _ _ _ _ _ _ _ _ _ ~

TABLE I A (continued)

SEMIANNUAL SUMM ATION OF GASEOUS RELEASES ALL AIRBORNE EFFLUENTS 1

QUARTERS 3 AND 4,1995 THIRD FOURTH EST TOTAL TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a)

A. FISSION AND ACTIVATION GASES

1. TOTAL RELEASE CURIES 2.72E+00 4.93E+00 20
2. AVEP >4E RELEASE RATE FOR PERIOD uCi/SEC 3.43E-01 6.21E-01
3. PERCENT OF TECH SPEC LIMIT N/A N/A B. RADIOlODINES
1. TOTAL LODINE-131 CURIES 9.33E-07 1.69E-06 23
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 1.176-07 2.13E-07
3. PERCENT OF TECH SPEC LIMIT N/A N/A C. PARTICULATE
1. PARTICULATE (HALF-LIVES > 8 DAYS)

CURIES 8.27E-07 1.97E-07 30

2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 1.04E-07 2.47E-08
3. PERCENT OF TECH SPEC LIMIT N/A N/A
4. GROSS ALPHA RADIOACTIVITY CURIES 1.88E-07 2.32E-07 D. TRITIUM
l. TOTAL RELEASE CURIES 3.1 lE+01 3.18E+01 14
2. AVERAGE RELEASE RATE FOR PERIOD uCi/SEC 3.91E+00 4.00E+00
3. PERCENT OF TECH SPEC LIMIT N/A N/A (a) Safety Analysis Calculation 87-063-00. January 6,1988 Page 2 of 2

l-l TABLEIB SEMIANNUAL AIRBORNE CONTINUOUS AND BATCH RELEASES GROUND LEVEL RELEASES FISSION GASES. IODINES, AND PARTICULATE i

l

\\

QUARTERS I AND 2,1995 l

CONTINUOUS RELEASES BATCH RELEASES FIRST SECOND FIRST SECOND NUCLlDE UNITS QUARTER QUARTER QUARTER QUARTER

1. FISSION GASES l

AR-41 CURIES 0.00E+00 0.00E+00 6.92E-01 3.26E-02 XE-133 CURIES 7.46E+00 1.69E+00 2.34E+01 3.73E-03 XE-135 CURIES 4.12E-01 1.22E-01 4.44E+00 3.30E-05 XE-131M CURIES 0.00E+00 0.00E+00 3.64E-03 2.49E-03 KR-85 CURIES 0.00E+00 0.00E+00 1.60E+00 8.15E-01 KR-85M CURIES 0.00E+00 0.00E+00 1.75E-01 0.00E+ 00 XE-133M CURIES 0.00E+00 0.00E+00 6.36E-01 0.00E400 KR-88 CURIES 0.00E+00 0.00E+00 1.73E.01 0.00E+00 KR-87 CURIES 0.00E+00 0.00E+00 1.53E-04 0.00E+00 XE-135M CURIES 0.00E+00 0.00E+00 9.94E-05 0.00E+00 l

TOTAL FOR PERIOD CURIES 7.87E+00 1.81 E+00 3.l lE+01 8.53E-01

2. IODINES I 131 CURIES 2.05E-06 1.24E-05 1.33E-09 2.65E-05 1-132 CURIES 7.45E-05 3.56E-04 1.14E-06 1.70E-04 1133 CURIES 7.38E-07 0.00E+00 1.08E-06 2.02E-04 I-134 CURIES 0.00E+00 0.00E+00 8.81 E-07 0.00E+00 1-135 CURIES 0.00E+00 0.00E+00 1.57E-06 0.00E+00 TOTAL FOR PERIOD CURIES 7.73E-05 3.68E-04 4.67E 06 3.98E 04
3. PARTICULATE CO 57 CURIES 1.58E-07 0.00E+00 0.00E+00 4.05E-07 CE-144 CURIES 0.00E+00 0.00E+00 0.00E+00 1.79E-05 CO-58 CURIES 0.00E+00 2.74E-07 0.00E+00 4.27E-04 CO-60 CURIES 0.00E+00 1.98E-07 0.00E+00 3.44E-04 CR-51 CURIES 0.00E+00 0.00E+00 0.00E+00 2.24E-04 CS-134 CURIES 0.00E+00 0.00E+00 0.00E+00 6.51 E-05 CS-137 CURIES 0.00E+00 0.00E+00 0.00E+00 1.53E-04 MN-54 CURIES 0.00E+00 0.00E+00 0.00E+00 1.13E-04 i

NB-95 CURIES 0.00E+00 0.00E +00 0.00E+00 4.52E-05 l

PR-144 CURIES 0.00E+00 0.00E+00 0.00E+00 1.79E-05 R U.105 CURIES 0.00E+00 0.00E+00 0.00E+00 3.99E-05 RU-106 CURIES 0.00E+00 0.00E4 00 0.00E400 1.45E-05 S B-125 CURIES 0.00E+00 0.00E+00 0.00E+00 2.34E 05 TC-99M CURIES 0.00E+00 0.00E+00 0.00E+00 5.22E-07 Page 1 of 3

TABLE IB (continued)

SEMIANNUAL AIRBORNE CONTINUOUS AND BATCH RELEASES GROUND LEVEL RELEASES

MSION GASES, IODINES, AND PARTICULATE QUARTERS 1 AND 2,1995 CONTINUOUS RELEASES BATCH RELEASES FIRST SECOND FIRST SECOND NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER

3. PARTICULATE

' ZR-95 CURIES 0.00E+00 0.00E+00 0.00E+00 3.llE-05 SP,-89 CURIES 7.31E-07 0.00E+00 0.00E+00 0.00E+00 SR-90 CURIES 2.23E-07 0.00E+00 0.00E+00 0.00E+00 PU-241 CURIES 1.14E-05 0.00E+00 0.00E+00 0.00E+00 ALPHA CURIES 1.89E-07 2.25E-07 0.00E+00 0.00E+00 TOTAL FOR PERIOD CURIES 1.24E-05 4.72E-07 0.00E+00 1.52E-03

4. TRITIUM H-3 CURIES 8.06E+00 2.70E+01 l1.38E+00 3.88E-01 Page 2 of 3
c

TABLE IB (continued)

SEMIANNUAL AIRBORNE CONTINUOUS AND BATCH RELEASES GROUND LEVEL RELEASES FISSION GASES, IODINES, AND PARTICULATE QUARTERS 3 AND 4,1995 f

i CONTINUOUS RELEASES B ATCH RELEASES

\\

THIRD FOURTH THIRD FOURTH j

NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER

1. FISSION GASES AR-41 CURIES 0.00E+00 0.00E+00 1.05E-01 4.33E-01 XE-133 CURIES 7.42E-01 3.47E+00 L57E-02 4.83E-01 XE-135 CURIES 2.93E-02 0.00E+00 1.07E-04 2.35E-01 XE-131M CURIES 8.65E-01 0.00E+00 2.52E-04 0.00E+00 KR-85 CURIES 0.00E+00 0.00E+00 9.65E-01 0.00E+00 KR-85M CURIES 0.00E+00 0.00E+00 0.00E+00 2.35E-02 XE-133M CURIES 0.00E+00 1.57E-01 0.00E+00 0.00E+00 KR-88 CURIES 0.00E+00 0.00E+00 1.12E-04 4.18E-02 KR-87 CURIES 0.00E+00 0.00E+00 0.00E+00 2.88E-02 XE-135M CURIES 0.00E+00 0.00E+00 0.00E+00 1.3 t E-02 XE-138 CURIES 0.00E+00 0.00E+00 0.00E+00 4.79E-02

~

TOTAL FOR PERIOD CURIES 1.64E+00 3.63E+00 1.09E+00 1.31E+00 i

2. IODINES I 131 CURIES 9.33E-07 1.69E-06 0.00E+00 0.00E+00 1-132 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1-133 CURIES 3.77E-06 4.78E-06 0.00E+00 0.00E+00 l-134 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1135 CURIES 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD CURIES 4.70E-06 6.48E 06 0.00E+00 0.00E+00
3. PARTICULATE CO 58 CURIES 0.00E+00 1.97E-07 0.00E+00 0.00E+00 SR-89 CURIES 6.28E 07 0.00E+00 0.00E+00 0.00E+00 SR-90 CURIES 1.99E-07 0.00E+00 0.00E+00 0.00E+00 ALPHA CURIES 1.88E-07 2.32E-07 0.00E+00 0.00E+00 TOTAL FOR PERIOD CURIES 1.02E-06 4.28E-07 0.00E+00 0.00E+00 l
4. TRITIUM l

H-3 CURIES 3.04E+01 2.40E+01 7.29E 01 7.81E+00 Page 3 of 3 1

TABLE 2A SEMIANNUAL SUMM ATION OF LIQUID RELEASES ALL LIQUID EFFLUENTS QUARTERS 1 AND 2,1995 FIRST SECOND EST TOTAL TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a)

A. FISSION AND ACTIVATION PRODUCTS

1. TOTAL RELEASE (NOTINCLUDING TRITIUM, GASES ALPHA)

CURIES 7.92E-04 5.34E-03 20

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 1.68E-09 1.24E-08
3. PERCENT OF APPLICABLE LIMIT N/A N/A B. TRITIUM
l. TOTAL RELEASE CURIES 3.1 IE+02 8.68E+0!

14

2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 6.61 E-04 2.02E-04
3. PERCENT OF APPLICABLE LIMIT N/A N/A C. DISSOLVED AND ENTRAINED GASES
1. TOTAL RELEASE CURIES 3.77E-02 1.15E-03 27
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 8.01E-08 2.68E-09 D. GROSS ALPHA RADIOACTIVITY
1. TOTAL RELEASE CURIES 1.97E-03 1.99E-04 29 E. WASTE VOLUME RELEASED (PRE-DILUTION)

GAL 4.94E+06 5.6SE+06 10 F. VOLUME OF DILUTION WATER USED GAL 1.19E+08 1.08E+08 10 (a) Safety Analysis Calculation 87-063-00. January 6,1988 Page I of 2

I I

TABLE 2A (continued)

SEMIANNUAL SUMMATION OF LIQUID RELEASES i

ALL LIQUID EFFLUENTS I

l QUARTERS 3 AND 4,1995 i

Tli!RD FOURTli ESTTOTAL i

TYPE OF EFFLUENT UNITS QUARTER QUARTER ERROR % (a) l l

A. FISSION AND ACTIVATION PRODUCTS

1. TOTAL RELEASE [NOT INCLUDING TRITIUM, GASES, ALPliA]

CURIES 3.04E-03 1.04E-03 20

2. AVERAGE DILUTED CONCENTRATION l

DURING PERIOD uCi/ML 9.54E-09 2.54E-09

3. PERCENT OF APPLICABLE LIMIT N/A N/A 1

B. TRITIUM i

1. TOTAL RELEASE CURIES 1.50E+02 2.44E+02 14 l
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 4.70E-04 5.97E-01 l
3. PERCENT OF APPLICABLE LIMIT N/A N/A C. DISSOLVED AND ENTRAINED GASES
1. TOTAL RELEASE CURIES 1.06E 03 2.42E-03 27
2. AVERAGE DILUTED CONCENTRATION DURING PERIOD uCi/ML 3.34E-09 5.90E-09 D. GROSS ALPliA RADIOACTIVITY l
1. TOTAL RELEASE CURIES 1.43E-03 9.71 E-03 29 E. WASTE VOLUME RELEASED (PRE-DILUTION)

GAL 5.79E+06 5.4]E+06 10 1

F. VOLUME OF DILUTION WATER USED GAL 7.84E+07 1.03E+08 10 (a) Safety Analysis Calculation 87-063-00, January 6.1988 Parc 2 of 2 1

1

l TABLE 2B SEMIANNUAL LIQUID CONTINUCUS AND B ATCH RELEASES TOTALS FOR EACH NUCLIDE RELEASED QUARTERS 1 AND 2,1995 CONTINUOUS RELEASES B ATCH RELEASES FIRST SECOND FIRST SECOND NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER

1. ALL NUCLIDES ALPHA CURIES 0.00E+00 0.00E+00 1.97E-03 1.99E-04 H-3 CURIES 0.00E+00 0.00E+00
3. I IE+02 8.68E+01 SR-90 CURIES 0.00E400 0.00E+00 2.49E-04 0.00E+00 XE-133 CURIES 0.00E+00 0.00E+00 3.56E-02 1.23E-04 XE-135 CURIES 0.00E+00 0.00E+00 1.11E-03 7.94E-06 CO-60 CURIES 0.00E+00 0.00E+00 3.07E-04 2.72E-03 XE-133M CURIES 0.00E+00 0.00E+00 6.88E-04 0.00E+00 CS-137 CURIES 0.00E+00 0.00E+00 4.66E-05 1.35E-04 I-131 CURIES 0.00E+00 0.00E+00 2.20E-06 9.95E-06 XE 131M CURIES 0.00E+00 0.00E+00 2.57E-04 0.00E+00 CS-134 CURIES 0.00E+00 0.00E+00 1.27E-05 8.30E-06 CE-144 CURIES 0.00E+00 0.00E+00 7.17E-05 9.4 ] E-05 M N-54 CURIES 0.00E+00 0.00E+00 7.98E-06 1.20E-04 PR-144 CURIES 0.00E+00 0.00E+00 7.17E-05 9.41 E-05 TE-129 CURIES 0.00E+00 0.00E+00 2.37E-05 0.00E+00 1-133 CURIES 0.00E+00 0.00E+00 0.00E+00 8.37E-06 CO-58 CURIES 0.00E+00 0.00E+00 0.00E+00 1.01E-03 NB-95 CURIES 0.00E+00 0.00E+00 0.00E+00 1.87E-04 CR-51 CURIES 0.00E+00 0.00E+00 0.00E+00 6.20E-04 FE-59 CURIES 0.00E+00 0.00E+00 0.00E+00 2.03E-05 ZR-95 CURIES 0.00E+00 0.00E+00 0.00E+00 1.20E-04 AG-110M CURIES 0.00E+03 0.00E+00 0.00E+00 1.11 E-05 CE-141 CURIES 0.00E+00 0.00E+00 0.00E400 4.44E-05 LA 140 CURIES 0.00E+00 0.00E+00 0.00E+00 1.30E-05 RU-106 CURIES 0.00E+00 0.00E+00 0.00E+00 9.32E-05 SN-ll3 CURIES 0.00E+00 0.00E+00 0.00E+00 1.43E-05 2U-103 CURIES 0.00E+00 0.00E+00 0.00E+03 1.66E-08 SB-125 CURIES 0.00E+00 0.00E+00 0.00E+00 3.21 E-08 SB-124 CURIES 0.00E+00 0.00E+00 0.00E+00 4.06E-06 ZR-97 CURIES 0.00E+00 0.00E+00 0.00E+00 2.81 E-06 RU-105 CURIES 0.00E+00 0.00E+00 0.00E+00 1.3 ] E-05 KR 85 CURIES 0.00E+00 0.00E+00 0.00E+00 1.02E-03 TC-99M CURIES 0.00E+00 0.00E+00 0.00E+00 2.81 E-06 TOTALS FOR PERIOD CURIES 0.00E+00 0.00E+00 3.11 E+02 8 68E+01 l

l l

l Page 1 of 2

l TABLE 2B(continued)

SEMIANNUAL LIQUID CONTINUOUS AND BATCH RELEASES l

TOTALS FOR EACH NUCLIDE RELEASED QUARTERS 3 AND 4,1995 CONTINUOUS RELEASES BATCH RELEASES THIRD FOURTH THIRD FOURTH NUCLIDE UNITS QUARTER QUARTER QUARTER QUARTER I. ALL NUCLIDES ALPHA CURIES 0.00E+00 0.00E+00 1.43E-03 9.71E-03 H-3 CURIES 0.00E+00 0.00E+00 1.50E+02 2.44E+02 XE-133 CURIES 0.00E+00 0.00E+00 8.74E-04 2.25E-03 XE-135 CURIES 0.00E+00 0.00E+00 2.08E-05 1.62E-04 CO-60 CU"!ES 0.00E+00 0.00E+00 2.52E-04 2.30E-04 CS-137 CURIES 0.00E+00 0.00E+00 1.45E-04 1.21E-05 XE-131M CURIES 0.00E+00 0.00E+00 1.69E-04 0.00E+00 i

CS-134 CURIES 0.00E+00 0.00E+00 9.02E-06 8.84E-06 i

CE-144 CURIES 0.00E+00 0.00E+00 3.04E-05 0.00E+00 J

MN-54 CURIES 0.00E+00 0.00E+00 3.28E-05 1.65E-05 PR-144 CURIES 0.00E+00 0.00E+00 3.04E-05 0.00E+00 CO-58 CURIES 0.00E+00 0.00E+00 1.56E-04 7.64E-04 NB-95 CURIES 0.00E+00 0.00E+00 2.39E-05 0.00E+00 ZR-95 CURIES 0.00E+00 0.00E+00 6.16E-06 0.00E+00 RU-106 CURIES 0.00E+00 0.00E+00 2.24E-05 0.00E+00 SN 113 CURIES 0.00E+00 0.00E+00 0.00E+00 2.50E-06 RU 103 CURIES 0.00E+00 0.00E+00 0.00E+00 2.76E-06 SB 125 CURIES 0.00E+00 0.00E+00 7.39E 06 0.00E+00 PU-241 CURIES 0.00E+00 0.00E+00 2.17E-03 0.00E+00 CM 243 CURIES 0.00E+00 0.00E+00 6,79E-06 0.00E+00 TC-99M CURIES 0.00E+00 0.00E+00 0.00E+00 2.17E-06 TC-101 CURIES 0.00E+00 0.00E+00 1.46E-04 0.00E+00 HF-181 CURIES 0.00E+00 0.00E+00 2.23E-06 0.00E+00 CO-57 CURIES 0.00E+00 0.00E+00 0.00E+00 3.33E-06 TOTALS FOR PERIOD l CURIES 0.00E+00 0.00E+00 1.50E+02 2.44E+02 l-

)

Page 2 of 2

L i

I-e a

a 4

. t!.

h 4

TABLE 5 DOSE AT THE SITE BOUNDARY AND TO THE NEAREST RESIDENT FROM GASEOUS EFFLUENTS SITE DOUNDARY NEAREST RESIDENT j

l LOCATION: 1.40 km SSE LOCATION: 1900.00 km WSW AGE GROUP: CHILD AGE GROUP: CHILD ORGAN UNITS DOSE

% LIMIT (a)

DOSE

% LIMIT (b)

1. GAMMA AIR DOSE
  • MRAD 1.06E-03 0.01 7.65E-04 N/A
2. BETA AIR DOSE
  • MRAD 1.78E-03 0.01 1.2EE-03 N/A
3. WHOLE BODY "*

MREM 2.5 ) E-03 N/A 1.31E-03 N/A

4. SKIN "*

MREM 3.56E-03 N/A 2.07E-03 N/A

5. BONE "

MREM l.55E-03 N/A 2.58E-03 0.02 1

6. LIVER "

MREM 4.1 SE-03 N/A 1.96E-02 0.13 i

7. TOTAL BODY "

MREM 4.18E-03 N/A 1.79E-02 0.12 l

8. THYROID **

MREM 4.22E-03 N/A 2.04E-02 0.14 i

9. KIDNEY "

MRD1 4.18E-03 N/A 1.82E-02 0.12

10. LUNG **

MREM 4.26E-03 N/A 1.78E-02 0.12

11. GI LLI **

MREM 4.1SE-03 N/A 1.77E-02 0.12

  • Dose from Noble Gases only

" Dose from Tritium, Radiciodines, and Particulate only

  • " Dose from Noble Gases plus Grcund Planc dose (a) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-01003) of 10 mrad gamma air dose and 20 mrad beta air dose.

(b) Annual dose limits of Offsite Dose Cr.iculation Manual (APA ZZ-01003) of 15 mrem to any organ from I-131.1-133, H-3 and particulate radionuclides with ha10ives prcater than 8 days.

PageIofI l

l l

a

TABLE 6 DOSE TO THE MEMDER OF THE PUBLIC FROM ACTIVITIES WITHIN TiiE SITE DOUNDARY EFFLUENT DIRECT DIRECT TOTAL DOSE WITHIN RADIATION RADIATION DOSE THE SITE FROM THE PROM OUTSIDI FOR THE ORGAN UNITS BOUNDARY UNIT TANKS YEAR

1. SKIN MREM 5.00E-04 N/A N/A 5.00E-04
2. BONE MREM 3.45E-04 8.79E-03 2.85E-04 9.42E-03
3. LIVER MREM 1.18E-03 8.79E-03 2.85E-04 1.03E-02
4. TOTAL BODY MREM 1.42E-03 8.79E-03 2.85E-04 1.05E-02
5. THYROID MREM 1.19E-03 8.79E-03 2.85E-04 1.03E-02
6. KIDNEY MREM 1.18E-03 8.79E-03 2.85E-04 1.03E-02
7. LUNG MREM 1.20E-03 8.79E-03 2.85E-04 1.03E-02
8. GI-LLI MREM 1.18E-03 8.79E-03 2.85E-04 1.03E-02 4

PageIof1

TABLE 7 TOTAL DOSE DUE TO THE URANIUM FUEL CYCLE -

(MEMBER OF THE l'UBLIC)-

DOSE FROM '

TOTAL DOSE DOSE ATTHE ACTIVITIES TO THE RESIDENCE WITHIN SITE MEMBER OF ORGAN UNITS LOCATION BOUNDARY THE PUBLIC

% LIMITS *

1. SKIN MREM 6.36E-04 5.00E-04 1.14E-03 0.00
2. BONE MREM 7.88E-04 9.42E-03 1.02E-02 0.04
3. LIVER MREM 5.22E-03 1.03E-02 1.55E-02

- 0.06 -

4. TOTAL BODY MREM 5.38E-03 1.05E-02 1.59E-02 0.06 -
5. THYROID -

MREM 5.39E-03 1.03E-0?.

1.56E-02 0.02

6. KIDNEY MREM 4.86E 1.03E-02 1.51 E 0.06
7. LUNG MREM 4.75E-03 1.03E 02.

1.50E-02 0.06

8. GI LLI MREM 4.95E-03 1.03E-02 1.52E-02 0.06 i
  • Annual dose limits from 40CFR190.10(a) of 25 mrem whole body,75 mrem to the thyroid, and 25 mrem to any other organ.

t-l t

i Page1ofI

.n

TABLE 3 DOSE DUE TO LIQUID EFFLUENTS (MEMBER OF TiiE PUBLIC) 1995 ORGAN UNITS DOSE LIMIT *

% LIMIT

1. BONE MREM 7.96E-03 10.00 7.96E-02
2. LIVER MREM 2.00E-02 10.00 2.00E-01
3. TOTAL BODY MREM 1.74E-02 3.00 530E-01
4. THYROID MREM 1.09E-02 10.00 1.09E-01
5. KIDNEY MREM 1.40E-02 10.00 1.40E-01
6. LUNG MREM 1.19E-02 10.00 1.19E-01
7. GI-LLI MREM 1.98E-02 10.00 1.98E-01
  • Annual dose limits of APA-ZZ-01003, Section 9.4.1.1.

" Reported dose includes the dose from the Logan Creek event.