ML20234D147

From kanterella
Jump to navigation Jump to search
Draft Concept of Util Offsite Planning Evaluation Criteria
ML20234D147
Person / Time
Issue date: 11/06/1987
From:
NRC
To:
Shared Package
ML20234D094 List:
References
FOIA-87-813 PROC-871106, NUDOCS 8801060469
Download: ML20234D147 (34)


Text

_ _ _ _ _ _ _. _ _ _ - --

l *;

y Draft 4

CONCEPT OF UTILITY OFFSITE PLANNING EVALUATION CRITERIA 1.

The concept of "offsite response organization" is adopted and defined as the utility offsite emergercy response organization along with other par-ticipating voluntary ud private organizations and local, State and Federal governments engaging in the development of off site emergency plans for a nuclear power plant.

Throughout the revised Evaluation l

Criteria "offsite response organization" replaces references to State and tocal governments.

2.

In addition, Evaluation Criteria were modified or added to compensate for lack of participat4cn-by State and local governments in the planning process, such as:

a.

Identification of the functior,s which require State and local authorization before implementing (A.2.a).

l b.

Provision cf additional personnel to advise and assist State and local officiah in an emergency (C.5).

l Provision for advising State and local of ficials on emergency actions c.

to be taken (0.4., E.6.a., J.10.f.).

d.

Provision for coordinating emergency messages with State and local 3

gesernments where possible (E.3.).

i Provision for communications with non participating State and local l

e.

emerger.y operations f acilities (F.1.).

1 l

f.

h ovi,sion for public information describing the role of the offsite l

response organization vs. the State and local organizations during the emergency (G.1.e.).

I 1

l g.

Establishment of an emergency operations center for use in directing j

and controlling of f site response functions (H.3.).

8901060469 071231' PDR FOIA WEIGSO7-813 PDR I

CRITERIA / UTILITY OFFSITE P dNS J2' L 11/06/87

Draft h.

Offsite response organization should have the means (even though they don't have the responsibility) for activating the alert and notification system (E.6.a. and J.9. ).

i.

Provision for encouraging participation in exercises and drills by State and local governments but not requiring it (N.6.).

j.

Provisiun of training to persons in the utility's offsite response organization who will be responders (0.4.k.).

k.

Provision for providing copies of the offsite plan to non participating State and local governments.

i l

CRITERIA / UTILITY OFFSITE PLANS

  1. F 14 11/06/87

Draft PROPOSED FOR INTERIM USE AND COMMENT Appendix 6 Evaluation Criteria for Utility Offsite Plans The following provides Criteria to be used for the development and evaluation of utility offsite emergency response plans.and preparedness.

(The Planning Standards are repeated here for convenience.)

These Evaluation Criteria modify those applicable to State and local response organizations and should be used in their place.

The following assumptions were used in developing the Evalua-tion Criteria in this appendix.

In an actual emergency, State and local officials will:

1.

exercise their best efforts to protect the health and safety of the public; 2.

cooperate with the utility and follow the utility offsite plan; and 3.

have the resources sufficient to implement those portions of the utility offsite plan where State or local response is necessary.

CRITERIA / UTILITY OFFSITE PLANS tr 11/06/87

Draft EVALVATION CRITERIA FOR UTILITY OFFSITE PLANS Planning Standards and Evaluation Criteria A.

Assignment of Responsibility (Organization Control)

Planning Standard Primary responsibilities for emergency response by the nuclear facility licensee, and by State and local organizations within the Emergency Planning Zones have been assigned, the emergency responsibilities of the various sup-porting organizations have been specifically established, and each principal response organization has staff to respond and to augment its initial response on a continuous basis.

Evaluation Criteria 1.

a.

The offsite plan shall identify the elements of the offsite response organization for Emergency Planning Zones (see Appendix 5).*

b.

The offsite response organization shall specify its concept of operations, and its relationship to the total effort.

The concept of operation will explain how the offsite response organization will function with non participating State and local governments, and will specify the various modes of operation.

  • 0ffsite response organization is defined as the utility offsite emergency response organization along with other participating voluntary and private organizations, and local, State and Federal governments engaging in the development of offsite emergency plans for a nuclear power plant.

CRITERIA / UTILITY OFFSITE PLANS 1

11/06/87

)

1 i

1 Draft j

]

L c.

The offsite plan shall illustrate these interrelationships in a block diagram.

This diagram will define the_ roles for the offsite; response organization and non participating State and local governments, and identify the lead interfaces.

d.

The offsite response organization;shall identify ~a specific individ-ual by title who shall be<in charge of'the emergency response.

q

]

The offsite' response organization-shall prov'ide for'24-hour per day e.

emergency response, including 24-hour per day manning of communica-tions links.

)

i 2.

a.

The.offsite response organization shall specify the' functions and j

responsibilities for major elements and, key individuals by title, of

')

emergency response, including th'e following:

Command and Control,.

Alerting and Notification, Communications, Public Information, Acci-dent Assessment, Public Health and Sanitation, Social Services, Fire and Rescue, Traffic Control, Emergency Medical' Services, Law Enforce-1 ment, Transportation, Protective Response (including authority to request Federal assistance.and-to initiate other protective. actions),

and Radiological Exposure Control..The. description,of these functions shall include a clear and concise summary such as a table of primary and support responsibilities using the agency as one axis, and the function as the other. This description shall specify those functions which require State and local authorization before implementing, such_

)

as:

i.

Directing traffic 11.

Blocking roadways, erecting barriers in roadways and channeling j

,. traffic; iii. Posting traffic signs on roadways; iv.

Removing obstructions from public' roadways, including towing'

{

vehicles;

.v.

Activating sirens and directing the broadcasting of EBS messages;.

l CRITERIA / UTILITY OFFSITE PLANS.

2 11/06/87

-j

.___C

d

-Draft 4

i vi.

Making decisions and recommendations to the public concerning.

protective actions for the plume exposure pathway; vii. Making decisions and recommendations to the public concerning-I protective actions for the ingestion exposure pathway; i

viii. Making decisions and recommendations ~to the public~concerning i

)

recovery and reentry, 3

ix.

Dispensing fuel from tank trucks to automobiles along roadsides; x.

Performing-access control at an EOC, relocation centers and.the-EPZ perimeters; and xi.

Agreements with other countries.

The plan shall also identify similar functions and' responsibilities'

~

and interfaces-for an anticipated State and local response to an

.i emergency.

l b.

-The offsite plan shall contain (by reference to specific acts, codes or statutes) the legal basis for such authorities.

3.

The offsite plan shall include written agreements referring to the con-cept of operations developed between Federal agencies, the offsite response organization, and other support organizations'having an emer-gency response role within the Emergency Planning Zones. The agreements-q shall identify the emergency measures-to be provided~and the mutually

{

acceptable criteria for their implementation, and.specif9 the. arrange-l ments for exchange of information. These agreements may be provided in' an appendix to the offsite plan or the offsite plan-itself may contain descriptions of these matters and a signature page in the plan may serve j

to verify the agreements.

The signature pa'ge format is appropriate for organizations where response functions are covered by' laws, regulations-

.j or executiye orders where separate written agreements are not necessary.

4.

The offsite response organization shall be capable of continuous ^(24-hour) 1 operations for a protracted period.

The individual in the offsite response organization who will be responsible for assuring continuity of' resources (technical, administrative, and material). shall 'be specified by. title'.

CRITERIA / UTILITY OFFSITE PLANS 3

11/06/87:-

1 I

L_ -

Draft i

B.

Onsite Emergency Organization (Not Applicable)

C.

Emergency Response Support and Resources i

Planning Standard l

i i

l Arrangements for requesting and effectively using assistance resources have l

been made, arrangements to accommodate State and local staff at the licensee's near-site Emergency Operations Facility have been made, and other organiza-tions capable of augmenting the planned response have been identified.

Evaluation Criteria 1.

The Federal government maintains in-depth capability to assist licensees, States and local governments through the Federal Radiological Emergenc9 Response Plan.

Each offsite response organization and licensee shall make provisions for incorporating the Federal response capability into its operation plan, including the following:

~

i a.

specific persons by title authorized to request Federal assistance; see A.1.d., A.2.a.

1 b.

specific Federal resources expected, including expected times of arrival at specific nuclear facility sites; and l

c.

specific licensee and offsite response organization resources avail-able to support the Federal response, e.g., air fields, command posts, telephone lines, radio frequencies and telecommunications centers.

7 2.

a.

The of f site response organization may dispatch representatives to the licensee's near-site Emergency Operations Facility.

(Technical analysis representatives at the near-site EOF are preferred.)

1 CRITERIA / UTILITY OFFSITE PLANS 4

11/06/87

i Draft b.

The licensee shall prepare for the dispatch of a representative to principal offsite governmental emergency operations centers.

j c.

The offsite response organization shall prepare for the dispatch ~of 3

a representative to principal of fsite governmental emergency opera-1 tions centers.

]

3.

The offsite response organization shall identify radiological labora-p tories and their general capabilities and expected availability to pro-vide radiological monitoring and analyses services which can be used in an emergency, i

4.

The offsite response organization shall identify nuclear and other facil-ities, organizations or individuals which can be relied upon in an emer-gency to provide assistance.

Such assistance shall be identified and supported by appropriate letters of agreement.

5.

The offsite response organization shall provide personnel to advise and assist State and local officials in implementing those portions of the l

I offsite plan where State or local response is identified.

9

)

r CRITERIA / UTILITY OFFSITE PLANS 5

11/06/87

Draft 1

l D.

Emergency Classification System 1

Planning Standard l

l A standard emergency classification and action level scheme, the bases of which-include facility system and effluent parameters, is in use by the nuclear facil-ity licensee, and State and local response plans call for reliance on informa-tion provided by facility licensees for determinations of minimum initial off-site response measures.

Evaluation Criteria l

l 3.

The offsite response organization shall establish an emergency classifi-cation and emergency action level scheme consistent with that established by the facility licensee.

4.

The offsite response organization should have procedures in place that provide for implementing emergency actions and that' provide for advising State and local officials on emergency actions to be taken which are con-sistent with the emergency actions recommended by the nuclear facility licensee, tak<ng into account local offsite conditions that exist at the t'.,e of the energency.

r CRITERIA / UTILITY OFFSITE PLANS 6

11/06/37

J Draft j

l E.

Notification Methods and Procedures i

l 1

Planning Standard I

l Procedures have been established for notification by the licensee of State and j

local response organizations and for notification of emergency personnel by 1

1 all response organizations; the content of initial and followup messages to j

response organizations and the public has been established; and means to pro-vide early notification and clecr instruction to the populace within the plume exposure pathway Emergency Planning Zone have been established.

)

Evaluation Criteria 1.

The offsite response organization shall establish procedures which describe the bases for notification of all response organizations consistent with the emergency classification and action level scheme set forth in Appen-

)

i dix 1 of NUREG-0654/ FEMA-REP-1, Rev. 1.

These procedures shall include i

1 means for verification of messages.

The specific details of verification j

need not Le included in the offsite plan.

2.

The offsite response organization shall establish procedures for alert-

)

ing, notifying, and mobilizing emergency response personnel.

i l

l 3.

The licensee in conjunction with the offsite response organization l

shall establish the content of the initial emergency messages to be sent I

from the plant.

These measures shall contain information about the class of emergency, whether a release is taking place, potentially affected population and areas, and whether protective measures may be necessary.

There shall be provisions for coordinating these messages with State and loca'l governments where possible.

l 4.

Each licensee shall make provisions for followup messages from the facil-ity to the offsite response organization (and to offsite authorities where possible) which shall contain the following information if it is known and appropriate:

l CRITERIA / UTILITY OFFSITE PLANS 7

11/06/87

Draft a.

location of incident and name and telephone number (or communications channel identification) of caller; b.

date/ time of incident; c.

class of emergency; d.

type of actual or projected release (airborne, waterborne, surface spill), and estimated duration / impact times; e.

estimate of quantity of radioactive material released or being re-1 leased and the points and height of releases; f.

chemical and physical form of released material, including estimates of the relative quantities and concentration of noble gases, iodines and particulate; l

g.

meteorological conditions at appropriate levers (wind speed, direc-tion (to and from), indicator of stability, precipitation,'if any);

h.

actual or projected dose rates at the boundary; projected integrated l

dose at site boundary; i.

projected dose rates and integrated dose at the projected peak'and at 2, 5 and 10 miles, including sector (s) affected; j.

estimate of any surface radioactive contamination inplant, onsite or offsite;

)

k.

licensee emergency response actions underway; 1.

recommended emergency actions, including protective measures; m.

request for any needed onsite support by offsite organizations; and l

l l

CRITERIA / UTILITY OFFSITE PLANS 8

3.1/06/87

Draft-n.

prognosis for worsening or termination of event based on plant information.

~

5.

The offsite response organization shall establish a system for disseminat-ing to the public appropriate information contained in initial. and -followup-messages received from the licensee including the. appropriate notification to appropriate broadcast media; e.g.,

the Emergency Broadcast Sy' stem (EBS).

6.

a.

The offsite response organization shall establish administrative and physical means, and the time required for notifying -and providing-prompt instructions to the public within.the plume' exposure pathway Emergency Planning Zone (see Appendix 3 of NUREG-0654/ FEMA-REP-l',

Rev. 1).

It shall be the licensee's responsibility to. demonstrate that such means exist', regardless of who implements this requirement.

The offsite response organization should have t.he means to activate the system.

7.

The of f site response organization-shall provide written messages intended for the public, consistent with the licensee's classification scheme. :In l-particular, draft messages to the public giving instructions with regard to specific protective actions to be taken by-occupants of affected areas shall be prepared and included as part of the offsite. plans.

Such mes-sages should include the appropriate aspects of sheltering,-e'.g., hand-kerchief over mouth, thyroid blocking or evacuation. The. role of the-licensee is to provide supporting information for the messages.

For ad

~

hoc respiratory protection see " Respiratory Protective Devices Manual" American Industrial Hygiene Association,1963 pp.123-126. '

O M

kThe prescripted messages should address the various conditions such as the dele-gation of authority by the State and local governments to the offsite response organization to issue prompt instructions.

CRITERIA / UTILITY OFFSITE PLANS 9

11/06/87.

Oraft F.

Emergency Communications Planning Standard Provisions exist for prompt communications among principal response organiza-tions to emergency personnel and to the public.

Evaluation Criteria 1.

The communication plans for emergencies shall include organizational titles and alternates for both ends of the communication links. Reliable l

primary and backup means of communication for the utility and the offsite response organization shall be established.

The utility and the offsite response organization shall establish the capability to communicate with

,u c ann t non participating State and local governments via car,ual-emergency telephone number (s) (e.g., 911) and via one other backup mode such as the ability to transmit via existing emergency radio frequencies.

Each plan shall include:

a.

provision for 24-hour per day notification to and activation of the offsite response organization's emergency response network; and at a minimum, a telephone link and alternate, including 24-hour per day manning of communication links that initiate emergency response actions.

b.

provision for communications with contiguous States and local govern-ments within the Emergency Planning Zones; l

c.

provision for communications as needed with Federal emergency response organizations; d.

provision for communications between the nuclear facility and the licensee's near-site Emergency Operations Facility, offsite response organization's emergency operations centers, and radiological monitor-ing teams; 1

l CRITERIA / UTILITY OFFSITE PLANS 10 11/06/87 l

7 Draft e.

provision for alerting or activating emergency personnel in each response organization; 2.

The offsite response organization shall ensure that a coordinated communication link for fixed and mobile medical support facilities exists.

3.

The offsite response organization shall conduct periodic testing of the entire emergency communications system (see evaluation criteria H.10, N.2.a and Appendix 3 of NUREG-0654/ FEMA-REP-1, Rev. 1).

k o

CRITERIA / UTILITY OFFSITE PLANS 11 11/06/87

Draft G.

Public Education and Information Planning Standard Information is made available to the public on a periodic basis on how they will be notified and what their initial actions shall be in an emergency (e.g., listening to a local broadcast station and remaining indoors), the principal points of contact with the news media for dissemination of informa-tion during an emergency (including the physical location or locations) are established in advance, and procedures for coordinated dissemination of infor-mation to the public are established.

Evaluation Criteria 1.

The offsite response organization shall provide a coordinated periodic (at least annu* ally) dissemination of information to the public regarding how they will be notified and what their actions should be in an emer-gency. This information shall include, but not net'essarily be limited to:

a.

educational information on radiation; b.

contact for additional information; c.

protective measures, e.g., evacuation routes and relocation centers, sheltering, respiratory protection, radioprotective drugs; d.

special needs of the handicapped; and e.

speri,al steps to be taken to describe the role of the offsite re-sponse organization vs. the State and local organizations during the emergency.

)

Means for accomplishing this dissemination may include, but are not necessarily l'imited to:

information in the telephone book; posting in public areas; and publications distributed on an annual basis.

j CRITERIA / UTILITY OFFSITE PLANS 12 11/06/87

Draft 2.

The public information program shall provide the permanent and transient adult population within the plume exposure EPZ an adequate opportunity to become aware of the information annually.

The programs should include provision for written material that is likely to be available in a resi-dence during an emergency.

Updated information shall be disseminated at least annually.

Signs or other measures (e.g., decals, posted notices, or other means, placed in hotels, motels, gasoline stations and phone booths) shall also be used to disseminate to any transient population within the plume exposure pathway EPZ appropriate information that will be helpful if an emergency or accident occurs.

Such notices should refer the transient to the telephone directory or other source of local emergency informatier, and guide the visitor to appropriate radio and television frequencies.

3.

The offsite response organization shall designate the points of contact and physical locations for use by news media during an emergency. This should include provisions for accommodating State and local government public information personnel assigned a role under'the offsite plan.

4.

a.

The offsite response organization shall designate a spokesperson who shall have access to all necessary information.

b.

The offsite response organization shall establish arrangements for timely exchange of information among designated spokespersons.

c.

The offsite response organization shall establish coordinated arrangements for dealing with rumors.

5.

The offsite response organization shall conduct coordinated programs at least annyally to acquaint news media with the offsite emergency plans, information concerning radiation, and points of contact (see G.1.e) for release of public information in an emergency.

CRITERIA / UTILITY OFFSITE PLANS 13 11/06/87 l

J

t Draft H.

Emergency Facilities and Equipment Planning Standard Adequate emergency facilities and equipment to support the emergency response are provided and maintained.

i Evaluation Criteria 3.

The offsite response organization shall establish an emergency opera-I tions center for use in directing and controlling offsite response functions.

4.

The offsite response ciganization shall provide for timely activation l

and staffing of the facilities and centers described in the offsite plan.

7.

The offsite response organization, vbere appropriate, shall provide for-l offsite radiological monitoring equipment in the vicinity of the nuclear l

facility.

l l

l

10. The offsite response organization shall make provisions to inspect, inventory and operationally check emergency equipment / instruments at least once each calendar quarter and after each use.

There shall be sufficient reserves of instruments / equipment to replace those which are i

removed from emergency kits for calibration or repair.- Calibration of eqeipment shall be at intervals recommended by the supplier of the equipment.

11. The offsite plan shall, in an appendix, include identification of emer-gency kits by general category (protective equipment, communications equipment,, radiological monitoring equipment and emergency supplies).
12. The offsite response organization shall establish a central point (pref-erably associated with the licensee's near-site Emergency Operations Facility), for the receipt and analysis of all field monitoring data and coordination of sample media.

CRITERIA / UTILITY OFFSITE PLANS 14 11/06/87

e Draft I.

Accident Assessment I

Planning Standard Adequate methods, systems and equipment for assessing and monitoring actual or l

potential offsite consequences of a radiological emergency condition are in use.

l l

Evaluation Criteria l

7.

The offsite response organization shall describe the capability and re-sources for field monitoring within the plume exposure Emergency Planning

)

l Zone which are an intrinsic part of the concept of operations for the facility.

8.

The offsite response organization, where appropriate, shall provide methods, equipment and expertise to make rapid assessments of the actual or potential magnitude and locations of any radiological hazards through liquid or gaseous release pathways.

This shall include activation, noti-fication means, field team composition, transportation, communication, monitoring equipment and estimated deployment times.

l 1

9.

The offsite response organization shall have a capability to detect and measure radiciodine concentrations in air in the plume exposure EPZ as low as 10 7 pCi/cc (microcuries per cubic centimeter) under field condi-tions.

Interference from the presence of noble gas and background radia-tion shall not decrease the stated minimum detectable activity.

10. The offsite response organization shall establish means for relating the various measured parameters (e.g., contamination levels, water and air activity levels) to dose rates for key isotopes (i.e., those given in Table 3, page 18 of NUREG-0654/ FEMA-REP-1, Rev. 1) and gross radioactivity measurements.

Provisions shall be made for estimating. integrated dose from the projected and actual dose rates and for comparing these estimates with the protective action guides.

The detailed provisions shall be described in separate procedures.

CRITERIA / UTILITY OFFSITE PLANS 15 11/06/87

1 1

Draft

11. Arrangements to locate and track the airborne radioactive plume shall be made, using either or both Federal and offsite response organization i

resources.

1 i

1 1

l i

1 i

t

?

e CRITERIA / UTILITY OFFSITE PLANS 16 11/06/87

Draft J.

Protective Response Planning Standard A range of protective actions have been developed for the plume exposure path-a way EPZ for emergency workers and the public. Guidelines for the choice of protective actions during an emergency, consistent with Federal guidance, are developed and in place, and protective actions for the ingestion exposure path-way EPZ appropriate to the locale have been developed.

Evaluation Criteria 2.

Each licensee and offsite response organization shall make provisions for evacuation routes and transportation for onsite individuals to some suit-able of fsite location, including alternative-s for inclement weather, high traffic density and specific radiological conditions.

9.

The of fsite response organization shall establish a' capability for imple-menting protective measures based upon PAGs and other criteria. The off-site response organization shall describe the means for recommending pro-tective actions to the public, for activating the alert and notification system, and for notifying the public of protective action recommendations.

This shall be consistent with the recommendations of EPA regarding exposure resulting from passage of radioactive airborne plumes (EPA-520/1-75-001),

and with those of DHHS/FDA regarding radioactive contamination of human food and animal feeds as published in the Federal Register on October 22, 1982 (47 FR 47073).

10.

The offsite response organization's plans to implement protective measures for the pipme exposure pathway shall include:

a.

Maps showing evacuation routes, evacuation areas, preselected radio-logical sampling and monitoring points, relocation centers in host areas, and shelter areas (identification of radiological sampling and monitoring points shall include'the designations in Table J-1 of CRITERIA / UTILITY OFFSITE PLANS 17 11/06/E7

Draft 1

NUREG-0654/ FEMA-REP-1, Rev. 1 or an equivalent uniform system described.

in the plan);

b.

Maps showing population distribution around the nuclear facility.

This shall be by evacuation areas (licensees shall also present the information in a sector format);

c.

Means for notifying all segments of the transient and resident population; d.

Means for protecting those persons whose mobility may be impaired due to such factors as institutional or other confinement. These means shall include notification, support and assistance in implement-ing protective measures where appropriate; i

1 e.

Provisions for the use of radioprotective drugs, particularly for emergency workers and institutional:ed persons within the plume exposure EPZ whose immediate evacuation may be' infeasible or very difficult, including quantities, storage, and means of distribution.

f.

The offsite response organization's plans should include the method by which decisions by the State Health Department for administering radioprotective drugs to the general population are made during an emergency and provide for advising State Health Departments regard-ing such decisions; and the predetermined condition under which such drugs may be used by offsite emergency workers; g.

Means of relocation; h.

Relpc,ation centers in host areas which are at least 5 miles, and preferably 10 miles, beyond the boundaries of the plume exposure emergency planning zone (see J.12.);

i.

Projected traffic capacities of evacuation routes under emergency conditions; CRITERIA / UTILITY OFFSITE PLANS 18 11/06/87

Draft j

j.

Control of access to evacuated areas and organization responsibili-ties for such control; k.

Identification of and means for dealing with potential impediments j

(e.g., seasonal impassability of roads) to use of evacuation routes, and contingency measures; 1.

Time estimates for evacuation of various sectors and distances based j

on a dynamic analysis (time-motion study under various conditions).

i for the plume exposure pathway emergency planning zone (see Appen-dix 4, NUREG-0654/ FEMA-REP-1, Rev. 1); and m.

The bases for the choice of recommended protective actions from the plume exposure pathway during emergency conditions.

This shall in-clude expected local protection afforded in residential units or other shelter for direct and inhalation exposurb, as well as evacua-I

)

tion time estimates.

11.

The offsite response organization shall specify the protective measures to be used for the ingestion pathway, including the methods for' protect--

ing the public from consumption of contaminated foodstuffs. This shall

-)

include criteria for deciding whether dairy animals shall be put on stored feed.

The offsite plan shall identify procedures for detecting contamination, for estimating the dose commitment consequences of uncon-trolled ingestion, and for imposing protection procedures such as impound-ment, decontamination, processing, decay, product diversion, and preserva-tion. Maps for recording survey and monitoring data, key land use data (e.g., farming), dairies, food processing plants, water sheds, water supply intake and treatment plants and reservoirs shall be maintained.

Provisions for maps s,howing detailed crop information may be by including reference to their availability and location and a plan for their use.

The maps shall start at the facility and include all of the 50-mile ingestion pathway EPZ.

Up-to-date lists of the name and location of all facilities which regularly process milk products and other large amounts of food or agricultural products originating in the ingestion pathway Emergency Planning Zone, but located elsewhere, shall be maintained.

CRITERIA / UTILITY OFFSITE PLANS 19 11/06/87

Draft 12.

The offsite response organization shall describe the means for register-ing and monitoring of evacuees at relocation centers in host areas.

The personnel and equipment available shall be capable of monitoring within about a 12-hour period all residents and transients in the plume exposure EPZ arriving at relocation centers.

6 O

1 l

CRITERIA / UTILITY OFFSITE PLANS 20 11/06/87

Draft K.

Radiological Exposure Control Planning Standard Means for controlling radiological exposures, in an emergency, are established for emergency workers.

The means for controlling radiological exposures shall include exposure guidelines consistent with EPA Emergency Worker and Lifesaving Activity Protective Action Guides.

Evaluation Criteria 3.

a.

The offsite response organization shall make provision for 24-hour-per-day capability to determine the doses received by emergency personnel involved in any nuclear accident, including volunteers.

They shall also make provisions for distribution of dosimeters, both self-reading and permanent record devices.

b.

The offsite response organization shall ensure' that dosimeters are read at appropriate frequencies and provide for maintaining dose records for emergency workers involved in any nuclear accident.

4.

The offsite response organization shall establish the decision chain for authorizing emergency workers to incur exposures in excess of the EPA General Public Protective Action Guides (i.e. EPA PAGs for emergency workers and lifesaving activities).

5.

a.

The offsite response organization, as appropriate, shall specify action levels for determining the need for decontamination, b.

The offsite response organization, as appropriate, shall establish the means for radiological decontamination of emergency personnel wounds, supplies, instruments and equipment, and for waste disposal.

CRITERIA / UTILITY OFFSITE PLANS 21 11/06/87

Draft i

L.

Medical and Public Health Support Planning Standard Arrangements are inade for medical services for contaminated injured individuals.2 Evaluation Criteria j

1.

The offsite response organization shall arrange for local and backup hospital and medical services having the capability for evaluation of radiation exposure and uptake, including assurance that persons providing these services are adequately prepared to handle contaminated individuals.

3.

The offsite response organization shall develop lists indicating the location of public, private and military hospitals and other emergency medical services facilities within the State or contiguous States con-sidered capable of providing medical support for any contaminated injured individual.

The listing shall include the name, lcrcation, type of facility and 2:bulatry/ncrN=bulat:,rgcapacities and any special radio-g logical capabilities.

These emergency medical services should be able to radiolo0ically monitor contamination personnel, and have facilities and trained personnel able to care for contaminated injured persons.

4.

The offsite response organization shall arrange for transporting victims of radiological accidents to medical support facilities.

2The availability of an integrated emergency medical services system and a public health emergency plan serving the area in which the facility is located and, as a migimum, equivalent to the Public Health Service Guide for Developing Health Disaster Plans, 1974, and to the requirements of an emergency medical services system as outlined in the Emergency Medical Services System Act of 1973 (PL 93-154 and amendments in 1979 PL 96-142), should be a part of and con-sistent with overall State or local disaster control plans and should be com-patible with the specific overall emergency response plans for the facility.

CRITERIA / UTILITY DFFSITE PLANS 22 11/06/37 L___________

e Draft b

)

id l

M.

Recovery and Reentry Planning and Postaccident Operations Planning Standard General plans for recovery and reentry are developed.

Evaluation Criteria l

1.

The offsite response organization, as appropriate, shall develop general f plans and procedures for reentry and recovery and describe the means by l

which decisions to relax protective measures (e.g., allow reentry into an evacuated area) are reeched.

This process should consider both existing sa and potential conditions, i

s.

3.

The offsite plan shall specify means for.j, forming members of the offsite g response organization that a recovery operation is to be initiated, and of any changes in the organizational structure that may occur.

4 The of f site plan shall establish alinethod for p' periodically fstimating total population exposure.

J l

l l

O kk

+

I t

e

,t CRITERIA / UTILITY OFFSITE PLANS 23 11/06/87 l

,t Draft a

J

-N.

Exercises and Drills planning Standard Periodic exercises are (will be) condudMJ to evaluate major portions of emer-t' gency response capabilities, periodic dri H s are (will be) conducted to develop and maintain key skills, and deficiencies identified as a result of exercises or drills are (will be) corrected.

Evaluation Criteria 1.

a.

An exercise is an event that tests the integrated capability and a major portion of the basic elements existing within emergency pre-paredness plans and organizations.

The emergency preparedness exercise shall simulate an emergency that results in offsite radio-logical releases which will require response by offsite response organizations.

Exercises sha h'be conducted as set forth in NRC and FEMA rules.

~

b.

An exercise shall incYude mobilization of offsite response organi-zation resources adequate to verify the capability to respond to an accident scenario requiring response.

This includes the demonstration ct4k AW capabilities to interface with non participating State and l

cc 4 n. wk wc wa.

local government, but does not,the use of standins for the antic-x ipated State and local response.

The offsite response organization shall provide for a critique of the biennial exercise by Federal and offsite response organization obserp rs/ evaluators.

The scenario shall be varied from exercise to exercise such that all major elements of the plans and preparednet.s organizations are tested within a six-year period.

Each organization shall make provisions to start an exercise between 6:00 p.m. Jod 4:00 a.m.

Exercises shall be conducted during different seasons of the year. At least one exercise shall be unannounced.

?

(

2.

A drill is a supervised instruction period aimed at testing, developing and maintaining skills in a particul"ar operation.

A drill is often a CRITERIA / UTILITY OFFSITE PLANS 24 11/06/87

s Draft l'

t component of an exercise. A-drill shall be supervised and evaluated by a l

qualified drill instructor. The offsite response organization shall j~

l conduct drills, in addition to the biennial en rcise'at the frequencies indicated below:

J l

a.

Communication Drills j

Communicatierts between the licensee up the offsite response organiza-tion within the plume exposure pathway Emergency Planning Zone shall be tested monthly.

Communications with Federal emergency responte organizations ^ and of f site response organizations within the ingestion pathway shall be tested quarterly. Communications between the nuclear facility, offsite resporise organization's operations entters, and field e sment teams shall be tested annually. Commi c.s tion drills shall'also include the aspect of understanding the content of messages.

If practicable, attempts should be wie to includs non-participating organizations in the monthly communications drilt s.

I l

\\

s J

l c.

Medical Emerg,ency Drills i

l A medical emert,ency drill involving a simulated contaminated individ-l j

ual which'contains provisions for participation by the local support services tgencies (i.e., ambulance and of fsite medical treatment facility) shall be conducted annually.

The offsite portions cf the medical drill may be performed as part of the required biennial i

exercise.

l d.

Radiological, Monitoring Drills I

Plapt, environs and radiological monitoring drills (onsite and of f-j site) shall be ccoducted annually.

These drO h shall include collection and ailalysis of all sample media (e.g., water, vegetation, soil and air), and provisions for communications and record keeping.

Where appropriate, local organizar.lons shall participate.

i CRITERIA /UTIUTY OFFSITC CLANS 25 11/06/li7 A -

h, I

Draft e.

Health Pigsics Drill i

Health Physics drills shall be conducted semiannually which involve l

response to, and analysis of, simulated elevated airborne and liquid samples and direct radiation measurements in the environment.

3.

' The offsite response organization shall describe how exercises and l

l drills are to be carried out to allow free play for decisionmaking and to meet the following objectives.

Pending the development of exercise j

scenarios and exercise evaluation guidance by NRC and FEMA the scenarios for use in exercises and drills shall include but not be limited to the-

)

l following:

l l

a.

The basic objective (s) of each drill and exercise and appropriate evaluation criteria; b.

The date(s), time period, place (s) and participating organizations; I

c.

Tha simulated events:

d.

A time schedule of real and simulated initiating events; e.

A narrative summary describing the conduct of the exercises or drills to include such things as simulated casualties, offsite fire department assistance, rescue of personnel, use of protective cloth-ing, deployment of radiological monitoring teams, and public infor-mation activities; and I

f.

A description of the arrangements for and advance materials to-be l;

proyiped to official observers.

.s l

4.

Official observers from Federal government and the offsite response l

organization shall observe, evaluate, and critique the required exer-cises. A I.ritique hil, be scheduled at the conclusion of the exercise CRITERIA / UTILITY OFFSITE PLANS 26 11/06/87 1.

l

Draft to evaluate the ability of organizations to respond as called for in the offsite plan.

The critique shall be conducted as soon as practicable after the exercise, and a formal evaluation shall result from the critique.

5.

The offsite response organization shall establish means for evaluating observer and participant comments on areas needing improvement, including emergency plan procedural changes, and for assigning responsibility for implementing corrective actions.

The offsite response organization shall establish management control used to ensure that corrective actions are implemented.

6, The offsite response organization shall attempt to involve the non participating X

State and local government in the exercises and drills, but their participation is not required.

CRITERIA / UTILITY OFFSITE PLANS 27 11/06/87

Draft O.

Radiological Emergency Response Training Planning Standard Radiological emergency response training is provided to those who may be called on to assist in an emergency.

j l

Evaluation Criteria 1.

The offsite response organization shall assure the training of appropri-ate individuals. The offsite response organization shall participate'in and receive training. Where mutual aid agreements exist between local agencies such as fire, police and ambulance / rescue, the training shall also be offered to the other departments who are members of the mutual aid district.2 4.

The offsite response organization shall establish a training program for instructing and qualifying personnel who will 'impleinent radiological emer-gency response plans.2 The specialized initial training and periodic retraining programs (including the scope, nature and frequency) shall be provided in the following categories:

a.

Directors or coordinators of the response organizations; l

b.

Personnel responsible for accident assessment; c.

Radiological monitoring teams and radiological analysis personnel; i

' Training'for hospital personnel, ambulance / rescue, police and fire department shall includir the procedures for notification, basic radiation protection, and their expected roles.

For those local services support organizations who will enter the site., training shall also include site access procedures and the identity (by position and title) of the individual in the onsite emergency organization who will control the organizations support activities.

Offsite l

emergency response support personnel should be provided with appropriate identi-fication cards where required.

21f the offsite response organization lacks the capability and resources to accomplish this training, they may look to the licensee and the Federal govern-ment (FEMA) for assistance in this training.

CRITERIA / UTILITY OFFSITE PLANS 28 11/06/87

Draft d.

Police, security and fire fighting personnel; f.

First aid and rescue personnel; g.

Local support services personnel including Civil Defense / Emergency Service personnel; h.

Medical support personnel; j.

Personnel responsible for transmission of emergency information and instructions; k.

Personnel responsible for interfacing with State and local responders.

5.

The offsite response organization shall provide for the initial and annual retraining of personnel with emergency response responsibilities.

6.

The offsite response organization shall offer training to non participating State and local governments and other organizations.

r CRITERIA / UTILITY OFFSITE PLANS 29 11/06/87

4 Draft j

l P.

Responsibility for the Planning Effort:

Development, Periodic Review and i

Distribution of Emergency Plans l

i i

Planning Standard j

i l

Responsibilities for plan development and review and for distribution of emer-gency plans are established, and planners are properly trained.

Evaluation Criteria

)

l 1.

The offsite response organization shall provide for the training of indi-I viduals responsible for the offsite planning effort.

l 2.

The offsite response organization shall identify by title the individual l

with the overall authority and responsibility for radiological emergency response planning.

l 3.

The offsite response organization shall designate a'n Emergency Planning Coordinator with responsibility for the development and updating of emer-gency plans and coordination of these offsite plans with other response organizations.

4.

The offsite response organization shall update its plan and agreements as needed, review and certify it to be current on an annual basis.

The update shall take into account changes identified by drills and l

exercises.

5.

The offsite emergency response plans and approved changes to the plans shall be forwarded to all participating organizations and appropriate individual.s with responsibility for implementation of the plans.

Revised pages shall be dated and marked to show where changes have been made.

6.

The offsite plan shall contain a detailed listing of supporting plans and their source.

CRITERIA / UTILITY OFFSITE PLANS 30 11/06/87 m_________

o

4 1

Draft 7.

The offsite plan shall contain as an appendix listing, by title, pro-cedures required to implement the offsite plan.

The listing shall include i

the section(s) of the offsite plan to be implemented by each procedure.

t 8.

The offsite plan shall contain a specific table of contents. Plans sub-1

)

mitted for review should be cross-referenced to these criteria.

l

10. The offsite response organization shall provide for updating telephone numbers in emergency procedures at least quarterly.

j

11. The offsite response organization shall provide copies of the offsite plan J

to non participating State and local government entities where interfaces are identified in Planning Standard A.

1 1

I a

1 l

l 1

l i

T a

l CRITERIA / UTILITY OFFSITE PLANS 31 11/06/87