Paul H. Kinld Vee President I

i Consolidatea Edison Company of New Wrk. Inc.

Indian Point Station Broadway & Bleakley Avenue Buchanan, NY 10511

'j 4

Telephone (914) 734-5340 May 1,1998 Fax: (914) 734 5923 Re:

Indian Point Unit No.1

{

and No. 2 Docket No. 50-3 and No. 50-247 Document Control Desk US Nuclear Regulatory Commission Mail Station Pl 137 Washington, DC 20555

SUBJECT:

Annual Effluent and Waste Disposal Report Attached is the Annual Effluent and Waste Disposal Report for 1997.

Should you have any questions regarding this matter, please contact Mr. Charles W. Jackson, Manager, Nuclear Safety and Licensing.

Very truly yours, f~l'Ill Attachments

/

/e

,e UV

.,V g

R

cc:

Mr. liubest J. Miller Regional Administrator - Region i US Nuclear Regulatory Commission 475 Allendale Road King of Pnissia, PA 19406 Mr. Jefferey F.11arold, Project Manager Project Directorate I-l Division of Reactor Projects I/II US Nuclear Regulatory Commission Mail Stop 14B-2 Washington, DC 20555 Senior Resident Inspector US Nuclear Regulatory Commission PO Box 38 Buchanan,NY 10511 Attn. Chief, Compliance Section New York State DEC Division of Water 50 Wolf Road Albany,NY 12233 Attn. Regional Water Engineer New York State DEC 202 Mamaroneck Ave.

White Plains, NY 10601 1

ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 1991 CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.

l INDIAN POINT UNIT NOS.1 & 2 DOCKET NOS. 50-03 & 50-247 MAY,1998

May,1993 Re:

Indiaa Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 i

i ANNUAL i

EFFLUENT AND WASTE DISPOSAL REPORT J191 FACILITY: Indian Point Station (Units 1 and 21 LICENSEE: Consolidated Edison Comoany of New York. Inc.

This information is provided pursuant to 10 CFR 50.36a(a)(2) and employs certain guidance as set fonh in Regulatory Guide 1.21. Revision 1. The numbered sections of this part of the report reference corresponding sections of the subject Regulatory Guide, pages 1.21-10 through 1.21-12. This Annual Effluent and Waste Disposal Report for Indian Point Units 1 and 2 covers discharges for 1997. The New York Power Authority, licensee of Indian Point Unit 3, will issue separate repons.

A.

Sunolemental Information and Definition 1.

Regulatorv Limits Indian Point Units I and 2 are presently subject to radioactive waste release specifications that are set forth in Appendix A to Facility Operation Licenses DPR-5 and DPR-26, entitled

" Technical Specifications and Bases" (Indian Pomt Unit No. 2 Technical Specification Section 3.9 " Radioactive Effluents").

2.

Maximum Permissible Concentrations (MPC)

Gaseous Effluents Concentrations of gaseous discharges in unrestricted areas are computed by producing release rate (Q) and the annual average dispersion factor (X/Q) at the most restrictive site boundary location. The mixture percent of MPC* is obtained by adding the effects of each nuclide; the l

effect of each nuclide is, in turn, the quotient of its computed concentration and its MPC.

Liauid Effluents All liquid discharges from Indian Point are made through a common discharge canal with a minimum of 100,000 gpm dilution water. The isotopic content, excluding tritium and dissolved noble 3;as, of continuous and batch mode discharges of liquid effluent for each calendar quarter has been added and a weighted average fraction of MPC* has been calculated for this isotopic mixture. The percent of the applicable limit reported in Section C of this document is the percent of MPC concentration of the time-average diluted concentration for each quarter.

The tritium limit has been established in the same manner as the limits for other isotopes in A-1

May,1993 Re:

Indian Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 liquid effluents. A derived MPC of 2x10" uCi/ml for dissolved noble gases has been conservatively adopted for liquid effluents due to the swimming pathway.

3.

Average Energy The average energy (B)* of the radionuclide mixture in releases of fission and activation gases for the four quarters in 1997 are provided below:

1st 2nd 3rd 4th Ouarter Ouarter Quin 1n Ouarter Beta 0.203 0.193 0.181 0.120 Gamma 0.077 0.050 0.177 0.137

  • Values in Mev/ Dis.

4.

Measurements and Anoroximations of Total Radioactivity a.

Fission and Activation Gases Analysis of effluent gases was performed in compliance with the requirements of Table 4.10-3 of the Technical Specifications. In the case ofisolated tanks (batch releases), the total activity discharged was based on an isotopic analysis of each batch and the volume of gas in that batch.

Vapor Containment ventilation discharges have generally been treated as batch releases.

At least one complete isotopic concentration analysis of containment air was performed per week. This was applied to gross analysis of the ventilation air performed prior to each discharge. This information was combined with the volume of air in each discharge to calculate the radionuclide composition of these discharges.

The continuous discharges were based on the isotopic content determined from weekly samples of ventilation air. This information was combined with total air volume discharged by this route. The accumulation of batch and containment ventilation releases was then used to determine total discharges.

b.&.c lodines and Particulates lodine-131 and particulate releases are quantified by collecting a continuous sample of ventilation air on a potassium-iodide impregnated activated charcoal cartridge and a glass-fiber filter paper. These samples are obtained as required by Table 4.10-3 of the Technical Specifications. The concentration ofisotopes found by analysis of these samples was combined with the volume of air discharged during the sampling period to calculate the amount of activity discharged.

For other iodine isotopes the ratio of each isotope to lodine-131 was determined by a monthly 24-hour composite sample. This ensures the proper identification of the A-2

l May,1998 Re:

Indian Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 short-lived I-133 and I-135 isotopes.

d.

Liould Effluents A sample of each batch discharge was taken and an isotopic analysis was performed in compliance with the requirements specified in Table 4.10-1 of the Technical Specifications. This isotopic concentration data was combined with information of volume discharged to determine the amount of each isotope discharged in the period.

1

\\

l Samples of continuous discharges have been taken and analyzed in compliance with Table 4.10-1 of the Technical Specifications. This concentration data was combined with the volume discharged to calculate the amount of each isotope discharged.

The above concentrations were used in conjunction with the actual dilution flow to calculate the fraction of maximum permissible concentration.

e.

Error Estimates The total error estimate is the geometric sum of counting uncettainty and sampling uncenainty, expressed as a percent. Sampling uncertainties are considered independent of activity level and largely fixed in value. However, counting uncertainties are activity level dependent. The percent counting uncertainty is the quotient of the I sigma (Poisson) uncenainty and the activity measured. This percent uncertainty is maximized at low activity levels, specifically at the lower limit of detection (LLD). It can be shown that the percent uncertainty at LLD is no more than 35%. But as most positive samples are detected at several multiples of LLD, at least, the percent uncertainty is more likely to be in the 8% to 12% range. Adding a consideration of fixed uncertainty of sampling, the total uncertainty is estimated to be 15%.

l 1

I l

A-3 l

May,1993 Re:

Indian Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 I

l 5.

Batch Releases:

1st 2nd 3rd 4th a.

Liquid Om Qin Qg Qin Number of Batch Releases 32 61 40 5

Total Time Pesiod of Batch Releases 2172 10531 2843 344 (Minutes) l Maximum Time Period of Batch Release 129 4430 100 90 (Minutes) l Average Time Period of Batch Release 68 173 71 69 (Minutes)

Minimum Time Period of Batch Release i1 15 30 50 (Minutes)

Average Stream Flow (cfs) 1995 22400 1996 33467 36467 14293 n/a(1) 1997 n/a(1) n/a(1) n/a(1) n/a(1)

(1)

This information obtained from the US Department of the Interior, is not available at this time.

1st 2nd 3rd 4th b.

Gaseous QL QA QA QE Number of Batch Releases 219 151 269 156 Total Time Period of Batch Releases 21348 22719 23864 29287 (Minutes)

Maximum Time Period of Batch Release 1929 3215 6165 5230 (Minutes)

Average Time Period of Batch Release 97 150 89 188 (Minutes)

Minimum Time Period of Batch Release 1

1 1

1 (Minutes) 6.

Abnormal Releases a.

Liquid - None b.

Gaseous - Two (7.5E-6Ci; 5.0E-3Ci; Total: 5.007E-3 Ci. )

l A-4

k

)

l

]

ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 4

B - GASEOUS EFFLUENTS i

1222 l

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.

INDIAN POINT UNIT NOS.1 & 2 DOCKET NOS. 50-03 & 50-247 MAY,1998

Con Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL AtCIUAL REPORT 1997 CASEOUS EFFLUENTS -- SUMMATION OF ALL RELFASES UNITS QUARTER QUARTER EST.

TOTAL j

1 2

ERROR,

~

A.

FISSION AND ACTIVATION GASES

1. TOTAL RELEASE Ci 6.56E+01 4.76E+02 1.50E+01
2. AVERAGE RELEASE pCi/Sec 8.43E+00 6.06E+01

)

RATE FOR PERIOD 3.

PERCENT OF TECHNICAL 1.95E-02 1.03E-01 SPECIFICATION LIMIT I

B.

IODINES l

J

1. TOTAL IODINE-131 Ci 6.37E-05 3.25E-04 1.50E+01
2. AVERAGE RELEASE pCi/Sec 8.20E-06 4.13E-05 RATE FOR PERIOD 3.

PERCENT OF TECHNICAL 4.02E-05 2.03E-04 SPECIFICATION LIMIT C.

PARTICULATES

1. PARTICULATES WITH Ci 1.47E-04 9.68E-05 1.50E+01 RALF-LIVES >8 DAYS
2. AVERAGE RELEASE pCi/Sec 1.89E-05 1.23E-05 RATE FOR PERIOD j

l 3.

PERCENT OF TECHNICA1 2.34E-05 1.36E-05 SPECIFICATION LIMIT

4. GROSS ALPHA Ci 4.20E-07 3.46E-07 RADIOACTIVITY D. TRITIUM
1. TOTAL RELEASE C1 1.42E-01 1.62E-01 1.50E+01 j
2. AVERAGE RELEASE pCi/Sec 1.83E-02 2.07E-02 RATE FOR PERIOD
3. PERCENT OF TECHNICAL 4.49E-05 5.07E-05 SPECIFICATION LIMIT ll 1

Con Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 GASEOUS EFFLUENTS FOR ALL RELFASE POINTS CONTINUOUS MODE BATCH MODE NUCLIDES UNITS QUARTER QUARTER QUARTER QUARTER RELEASED 1

2 1

2

1. FISSION AND ACTIVATION GASES I

H3 C1 1.42E-01 1.62E-01 0.00E+00 0.00E+00 C14 Ci 9.60E-01 6.60E-01 0.00E+00 0.00E+00 Ar41 Ci 2.07E-03 2.30E-03 3.03E-01 3.01E-01 Kr85m Ci 2.70E-03 1.32E-03 4.77E-01 5.59E-01 Kr85 Ci 0.00E+00 0.00E+00 3.78E+00 1.45E+00 Kr87 Ci 2.13E-03 1.16E-03 1.20E-01 9.10E-02 Kr88 Ci 3.88E-03 3.62E-03 5.08E-01 4.81E-01 Xe131m Ci 0.00E+00 1.21E+01 1.17E+00 5.89E+00 Xe133m Ci 0.00E+00 4.45E-01 1.62E-01 4.08E+00 Xe133 C1 1.08E+01 9.88E+01 4.42E+01 3.45E+02 Xe135m Ci 1.13E-01 2.84E-03 3.74E-02 3.04E-02 Xe135 Ci 1.06E-02 6.66E-01 2.87E+00 5.69E+00 Xe138 Ci 1.17E-03 3.61E-04 1.14E-02 1.60E-02 TOTAL FOR PERIOD Ci 1.20E+01 1.13E+02 5.37E+01 3.63E+02 (ABOVE) l 11 2

Con Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 GASEOUS EFFLUENTS FOR ALL RELEASE POINTS CONTINUOUS MODE NUCLIDES UNITS QUARTER QUARTER RELEASED 1

2 2.

IODINES I131 Ci 6.37E-05 3.25E-04 I133 Ci 2.05E-05 1.34E-05 i

I132 Ci 0.00E+00 1.51E-06 TOTAL FOR PERIOD Ci 8.42E-05 3.40E-04 (ABOVE) t CONTINUOUS MODE NUCLIDES UNITS QUARTER QUARTER I

RELEASED 1

2 3.

PARTICULATES Co60 Ci 5.98E-05 2.45E-05 Cs137 Ci 8.61E-05 6.80E-05 Ni63 Ci 8.94E-07 8.62E-07 Fe55 Ci 0.00E+00 3.54E-06 TOTAL FOR PERIOD Ci 1.47E-04 9.68E-05 j

(ABOVE) i 11 3

Con Edison Indian Point Station EFFLUEN'I' AND WASTE DISPOSAL ANNUAL REPORT 1997 CASEOUS EFFLUENTS -- SUMMATION OF ALL RELEASES l

UNITS QUARTER QUARTER EST.

TOTAL 3

4

ERROR, A.

FISSION AND ACTIVATION CASES l

1. TOTAL RELEASE Ci 5.13E+00 6.15E-01 1.50E+01
2. AVERAGE RELEASE pCi/Sec 6.45E-01 7.74E-02 RATE FOR PERIOD 3.

PERCENT OF TECHNICAL 1.88E-03 2.31E-04 i

SPECIFICATION LIMIT l

l B.

IODINES

1. TOTAL IODINE-131 Ci 0.00E+00 0.00E+00 1.50E+01
2. AVERAGE RELEASE pCi/Sec 0.00E+00 0.00E+00 RATE FOR PERIOD 3.

PERCENT OF TECHNICAL 0.00E+00 0.00E+00 SPECIFICATION LIMIT C.

PARTICULATES 1.

PARTICULATES WITH Ci 5.99E-05 1.74E-04 1.50E+01 HALF-LIVES >8 DAYS

2. AVERAGE RELEASE pCi/Sec 7.54E-06 2.19E-05 RATE FOR PERIOD
3. PERCENT OF TECHNICAL 9.58E-06 2.09E-05 SPECIFICATION LIMIT
4. GROSS ALPHA Ci 3.26E-07 4.18E-07 RADIOACTIVITY D.

TR1 TIUM

1. TOTAL RELEASE Ci 8.77E-02 1.96E-01 1.50E+01
2. AVERAGE RELEASE pCi/Sec 1.10E-02 2.46E-02 RATE FOR PERIOD
3. PERCENT OF TECHNICAL 2.71E-05 6.04E-05 SPECIFICATION LIMIT 11-4

e3n Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 CASEOUS FFFLUENTS FOR ALL RELEASE POINTS CONTINUOUS MODE BATCH MODE NUCLIDES UNITS QUARTER QUARTER QUARTER QUARTER RELEASED 3

4 3

4

1. FISSION AND ACTIVATION GASES H3 Ci 8.77E-02 1.96E-01 0.00E+00 0.00E+00 C14 Ci 1.72E+00 3.70E-01 0.00E+00 0.00E+00 Ar41 Ci 0.00E+00 0.00E+00 4.21E-01 4.31E-02 Kr85m Ci 0.00E+00 0.00E+00 3.33E-02 6.93E-03 Kr85 Ci 0.00E+00 0.00E+00 9.87E-03 0.00E+00 Kr87 Ci 0.00E+00 0.00E+00 1.57E-02 5.99E-03 Kr88 Ci 0.00E+00 0.00E+00 3.56E-02 8.86E-03 Xe131m Ci 0.00E+00 0.00E+00 3.32E-03 0.00E+00 Xe133m Ci 0.00E+00 0.00E+00 2.83E-03 6.50E-04 Xe133 Ci 0.00E+00 0.00E+00 2.21E+00 8.66E-02 Xe135m Ci 0.00E+00 0.00E+00 3.50E-02 1.07E-02 Xe135 Ci 0.00E+00 0.00E+00 6.30E-01 8.07E-02 Xe138 Ci 0.00E+00 0.00E+00 9.62E-03 1.02E-03 TOTAL FOR PERIOD Ci 1.81E+00 5.66E-01 3.41E+00 2.45E-01 (ABOVE) 11-5 J

Con Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 GASEOUS EFFLUENTS FOR ALL RFEFASE POINTS CONTINUOUS MODE NUCLIDES UNITS QUARTER QUARTER RELEASED 3

4 2.

IODINES TOTAL FOR PERIOD Ci 0.00E+00 0.00E+00 (ABOVE) l CONTINUOUS MODE NUCLIDES UNITS QUARTER QUARTER RELEASED 3

4 3.

PARTICULATES j

CoS8 Ci 0.00E+00 4.04E-05 Co60 Ci 2.75E-05 4.09E-05 Cs137 Ci 3.18E-05 9.13E-05 Ni63 Ci 5.84E-07 1.22E-06 Fe55 Ci 2.78E-08 0.00E+00 TOTAL FOR PERIOD Ci 5.99E-05 1.74E-04 (ABOVE) 11 6

l ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT C - LIOUID EFFLUENTS 1991.

l 1

1-l CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.

INDIAN POINT UNIT NOS. ;'& 2 DOCKET NOS. 50-03 & 50-247 M AY,1998 j

Con Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 LIQUID EFFLUENTS -- SUMMATION OF ALL RELEASES UNITS QUARTER QUARTER EST.

TOTAL 1

2

ERROR, A. FISSION AND ACTIVATION PRODUCTS
1. TOTAL RELEASE (EXCL.

Ci 8.47E-02 1.88E-01 1.50E+01 TRIT., GASES, ALPHA)

2. AVERAGE DILUTED pCi/ml 3.72E-10 1.09E-09 CONC. DURING PERIOD 3.

PERCENT OF 4.29E-03 5.68E-03 APPLICABLE LIMIT B.

TRITIUM

1. TOTAL RELEASE Ci 2.79E+02 1.93E+02 1.50E+01
2. AVERAGE DILUTED pei/mi 1.23E-06 1.13E-06 CONC. DURING PERIOD
3. PERCENT OF 4.09E-02 3. 7.J J2 APPLICABLE LIMIT C.

DISSOLVED AND ENTRAINED GASES

1. TOTAL RELEASE Ci 6.93E-02 5.64E-01 1.50E+01
2. AVERAGE DILUTED pCi/ml 3.04E-10 3.28E-09 CONC. DURING PERIOD
3. PFRCENT OF 1.52E-04 1.64E-03 APPLICABLE LIMIT D. GROSS ALPHA RADIOACTIVITY
1. TOTAL RELEASE Ci 0.00E+00 0.00E+00 5.00E+01 E.

VOLUME WASTE RELEASED LITERS 5.63E+07 2.52E+07 1.00E+01 l

(PRIOR TO DILUTION)

F.

VOLUME DILUTION WATER LITERS 2.28E+11 1.72E+11 1.00E+01 l USED DURING PERIOD C1

Con Edison Indian Point Station EFFLUEI'T AND WASTE DISPOSAL ANNUAL REPORT 1997 LIQUID EFFLUENTS FOR ALL RELEASE POINTS CONTINUOUS MODE BATCH MODE NUCLIDES UNITS QUARTER QUARTER QUARTER QUATTFR RELEASED 1

2 1

2 H3 Ci 1.42E-01 2.77E-02 2.79E+02 1.93E+02 Cr51 Ci 0.00E+00 0.00E+00 2.27E-03 1.77E-02 Mn54 Ci 0.00E+00 0.00E+00 2.38E-04 1.28E-03 Fe55 Ci 0.00E+00 0.00E+00 7.32E-03 1.68E-02 Fe59 Ci 0.00E+00 0.00E+00 1.52E-04 1.30E-04 CoS8 Ci 0.00E+00 0.00E+00 7.90E-03 4.17E-02 Co60 Ci 0.00E+00 0.00E+00 B.56E-03 2.30E-02 Ni63 Ci 7.65E-04 5.83E-03 3.41E-03 4.53E-03 Sr90 Ci 6.08E-04 8.31E-04 0.00E+00 0.00E+00 Nb95 Ci 0.00E+00 0.00E+00 1.25E-04 9.98E-04 Ag110m Ci 0.00E+00 0.00E+00 0.00E+00 1.70E-04 I131 Ci 1.30E-03 6.82E-04 0.00E+00 0.00E+00 I132 Ci 7.92E-06 2.43E-05 0.00E+00 0.00E+00 I133 Ci 4.18E-04 2.70E-04 0.00E+00 0.00E+00 Cs134 Ci 4.70E-04 4.50E-04 7.15E-04 1.34E-03 Cs137 Ci 4.48E-02 5.05E-02 2.79E-03 1.51E-03 Sb124 Ci 0.00E+00 0.00E+00 1.33E-03 6.95E-03 Sb125 Ci 0.00E+00 0.00E+00 5.50E-03 1.21E-02 Te123m Ci 0.00E+00 0.00E+00 7.17E-06 8.12E-04 Sn113 Ci 0.00E+00 0.00E+00 0.00E+00 1.93E-04 TOTAL FOR PERIOD Ci 1.90E-01 8.63E-02 2.79E+02 1.93E+02 (ABOVE)

C-2

Con Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 LIQUID EFFLUENTS FOR ALL RELEASE POIN'I'S LIQUID EFFLUENTS (CONTD)

CONTINUOUS MODE BATCH MODE NUCLIDES UNITS QUARTER QUARTER QUARTER QUARTER RELEASED 1

2 1

2 Xe133 Ci 2.48E-04 3.45E-03 6.77E-02 5.56E-01 Xe131m Ci 0.00E+00 0.00E+00 3.70E-04 1 14E-03 Xe135 Ci 0.00E+00 6.66E-05 3 38E-04 3.43E-04 Xe133m Ci 0.00E+00 0.00E+00 6.38E-04 2.77E-03 C-3

Con Edison Indian Point Station EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 LIQUID EFFLUENTS -- SUMMATION OF ALL RELEASES UNITS QUARTER QUARTER EST.

TOTAL 3

4

ERROR, A.

FISSION AND ACTIVATION PRODUCTS

1. TOTAL RELEASE (EXCL.

Ci 1.25E-01 4.45E-02 1.50E+01 TRIT., GASES, ALPHA)

2. AVERAGE DILUTED pCi/ml 4.72E-10 1.93E-10 CONC. DURING PERIOD 3.

PERCENT OF 2.33E-03 1.94E-03 APPLICABLE LIMIT B. TRITIUM

1. TOTAL RELEASE Ci 5.46E+01 4.94E+00 1.50E+01 2.

AVERAGE DILUTED pCi/ml 2.06E-07 2.14E-08 i

CONC. DURING PERIOD 3.

PERCENT OF 6.86E-03 7.13E-04 APPLICABLE LIMIT C.

DISSOLVED AND ENTRAINED GASES

1. TOTAL RELEASE Ci 1.32E-05 0.00E+00 1.50E+01
2. AVERAGE DILUTED pCi/ml 4.96E-14 0.00E+00 CONC. DURING PERIOD 3.

PERCENT OF 2.48E-08 0.00E+00 APPLICABLE LIMIT D.

GROSS ALPHA RADIOACTIVITY

1. TOTAL RELEASE Ci 0.00E+00 0.00E+00 5.00E+01 E. VOLUME WASTE RELEASED LITERS 3.65E+07 1.72E+07 1.00E+01 l

l (PRIOR TO DILUTION) j F. VOLUME DILUTION WATER LITERS 2.65E+11 2.31E+11 1.00E+01 USED DURING PERIOD i

l C-4

l EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 1997 LIQUID EFFLUENTS FOR ALL RELEASE POINTS CONTINUOUS MODE BATCH MODE NUCLIDES UNITS QUARTER QUARTER QUARTER QUARTER RELEASED 3

4 3

4 H3 Ci 3.15E-02 2.70E-02 5.46E+01 4.91E+00 Cr51 Ci 0.00E+00 0.00E+00 7.03E-03 0.00E+00 Mn54 Ci 0.00E+00 0.00E+00 6.53E-04 0.00E+00 Fe55 Ci 0.00E+00 0.00E+00 3.66E-03 1.09E-04 CoS8 Ci 0.00E+00 0.00E+00 1.14E-02 2.63E-04 Co60 Ci 5.48E-04 0.00E+00 4.95E-03 6.79E-04 Nf63 C1 1.18E-06 8.31E-04 9.59E-03 1.58E-03 Sr90 Ci 8.54E-04 6.82E-04 0.00E+00 0.00E+00 I131 Ci 0.00E+00 0.00E+00 0.00E+00 4.72E-05 Cs134 Ci 2.51E-04 6.21E-05 0.00E+00 3.97E-06 Cs137 Ci 5.31E-02 3.84E-02 1.45E-04 3.45E-04 Sb124 Ci 0.00E+00 0.00E+00 9.78E-03 3.75E-04 Sb125 Ci 0.00E+00 0.00E+00 2.30E-02 1.09E-03 Te123m Ci 0.00E+00 0.00E+00 1.56E-04 0.00E+00

{

TOTAL FOR PERIOD Ci 8.63E-02 6.70E-02 5.46E+01 4.92E+00 i

(ABOVE) t LIQUID EFFLUEITI'S (COITI'D)

CONTINUOUS MODE BATCH MODE NUCLIDES UNITS QUARTER QUARTER QUARTER QUARTER RELEASED 3

4 3

4 l

Xe135 Ci 0.00E+00 0.00E+00 1.32E-05 0.00E+00 l

l l

C-5

i ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT D - SOI ID WASTE 1222 1

i

)

)

i CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.

INDIAN POINT UNIT NOS.1 & 2 DOCKET NOS. 50-03 & 50-247 MAY,1998

May,1998 Re:

Indian Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 Solid Radwaste Disposal Repon 1997. Solid Radwaste Shipped Offsite for Burial, Reprocessing, or Disposal (No irradiated fuel).

12 MONTH PERIOD 1.

Tyne of Waste IJmis Class A Class B Class C Error. %

3

a. Spent Resins, m

20.89 9.24 0

-50/+100 sludges, etc.

Ci 86.49 364.86 0

25 m'

18.21 0

0 N/A

b. DAW Ci 23.62 0

0 25

c. Irradiated m'

O O

O N/A components Ci 0

0 0

N/A control rods, etc.

2.

Estimate of major nuclide composition in percent (by type of waste) a.

H-3 1

Ni-63 15 Cs-137 39 Ce-144 1

Co-60 21 Sb-125 3

Fe-55 11 Other 9

b.

Nb-95 2

Sb-125 3

Zr-95 2

Sb-124 5

Mn-54 2

Fe-55 24 Co-60 33 Cs-137 8

Co-58 4

Ni-63 17 This is the total of DAW both buried and awaiting processing at a volume reeduction facility.

D-1

May,1993 Re:

Indian Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 Solid Radwaste Disposal Report 1997. Solid Radwaste Shipped Offsite for Burial, Reprocessing, or Disposal (No irradiated fuel).

12 MONTH PERIOD 1.

Tvoc of Waste Umts Class A Class B Class C Error. %

2

a. Spent Resins, m

20.89 9.24 0

-50/+100 sludges, etc.

Ci 86.49 364.86 0

25 m'

18.21 0

0 N/A

b. DAW Ci 23.62 0

0 25

c. Irradiated m'

0 0

0 N/A components Ci 0

0 0

N/A control rods, etc.

2.

Estimate of major nuclide composition in percent (by type of waste) a.

H-3 1

Ni-63 15 Cs-137 39 Ce-144 1

Co-60 21 Sb-125 3

Fe-55 1I Other 9

b.

Nb-95 2

Sb-125 3

Zr-95 2

Sb-124 5

Mn-54 2

Fe-55 24 Co-60 33 Cs-137 8

Co-58 4

Ni-63 17 o

This is the total of DAW both buried and awaiting processing at a volume reeduction facility.

D-1

May,1998 Re:

Indian Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 3.

Solid Waste Disposition Number of Shioments Mode of Transnortation Destination 7

Cask Truck Barnwell, SC 10 Flat Bed Truck Oak Ridge, TN 3

Flat Bed Truck Wampum, PA 4.

Solid Waste Containers a.

7 High Integrity Containers b.

13 Cargo Container 5.

Waste Class Container Gass.A Class B Class C High Integrity Containers 4

3 0

Cargo Containers 13 0

0 Note:

Item 4b is the number of containers shipped offsite for volume reduction not the total number of containers buried.

Note:

Curies in item 1 are measured using the Radman (Waste Management Group) software program.

D-2 l

I l

i l

ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT E - RADIOLOGICAL IMPACT ON MAN

)

1221 1

\\

l l

1 l

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.

INDIAN POINT UNIT NOS.1 & 2 DOCKET NOS. 50-03 & 50-247 MAY,1998

l May,1998 Re:

Indian Point Unit Nos.1 & 2 Docket Nos. 50-03 & 50-247 RADIOLOGICAL IMPACT EVALUATION Doses from gaseous immersion, inhalation, ground deposition, and vegetation ingestion were evaluated for the nearest residence likely to be occupied in the critical sector for each pathway and were combined to provide a I

conservative determination of the nwnum individual offsite radiation dose from these pathways. Calculations were performed for members of the public on site for this reporting period. To this end, it is assumed that memben; of the public on-site are exposed 2 hocrs per year. Based on an assumed on-site location most likely to be occupied, a gaseous effluent dispersion factor is obtained. The dose is then computed with consideration for the total effluents released, the on-site dispersion factor and the exposure time. Doses to such individuals were found to be sigaificantly less than one percent of the maximum individual offsite dose. Doses were also evaluated for all sectors assuming an individual ingesting milk and meat from a cow located at a 5.0 mile distance. In all cases these evaluations were performed using the models presented in Regulatory Guide 1.109.

All releases were evaluated using actual meteosological conditions existing during the release period.

Integrated dose from the population within 50 miles of Indian Point from gaseous effluents were computed based on ths.,ost current population data.*

Dose calculations for liquid pathways to individuals and populations are computed for a year. The LADTAP 11 computer program that is utilized for these calculations incorpotated the calculation model and parameters that are presented in Regulatory Guide 1.109.

The fish, invertebrate, algae, drinking, shoreline, swimming and boating pathways are calculated for the adult, teenager, child and infant. These calculations are performed for reasons such as estimating the population water consumption dose, the population recreation dose, and cost-benefit analysis.

NUREG-0017. " Calculation of Release of Radioactive Materials in Gaseous and Liquid Effluents from Pressurized Water Reactors", assumes an annual release of 8.0 Ci/yr of Carbon-14. Therefore, to be consistent with NUREG-0017, a release of 3.7 Curies of Carbon-14 was assumed for t' e year,(adjusted for actual power operating capacity) in addition to the radioactive materials measured in Indian Point's gaseous effluents.

This impact c =.Naticn demonstiates that the dose commitment to man from the operation of Indian Point Unit Nos. I and 2 is negligible, and is well below the levels set forth in 10 CFR 20,10 CFR 50, and the Indian Point Unit Nos. I and 2 Technical Specifications.

o Population data was based on the 1990 census.

l E-1

2 7

1 4

.2 s -

o0 N5 i&

t n3 U0 t

0 n

i5 o

P s 8

o n

9 aN 9

i t 1

d e nk

,y I

c a

o e

M RD 2

2 3

1 1

m E

E E

E E

e e

A 3

1 2

8 9

n R

/

0 8

8 9

6 oBM N

1 1

1 2

6

.c i

l bu

)2 p

d 3

3 2

3 1

1 e

N i

m E

E E

E E

h e

o t

2 A

g r

e R

A 3

0 8

9 6

o a

v D

M P

h 8

5 4

9 3

/

t N

T m

N 2

4 5

1 e

1 N

s A

o 1

O 2

d 1

T d

1 S

T C

e e

d i

n A

i I

u b

N P

7 G

m 9

U M

2 I

y o

9 r

c E

TN L

o 2

3 a

1 t

A a

m E

E e

I O

C u

n e

3 A

3 A

A A

a l

t R

3 P

I g

i l

9 k

/

/

/

/

u G

e N

O R

S m

3 N

2 N

N N

c l

A L

e ca I

D O

cn o

I t

N D

e r

3 t

I e

A f

u R

e o

o

(

i N

R n

t y

P it r

n d

U o

P 2

3 3

2 3

1 t

B A

T in l

m E

E E

E E

E o

a e

2 7

0 8

6 4

o R 2

9 5

8 9

3 D

P t

Tm A

n 2

3 5

1 1

1 a

L i

dn d

I e

r h

o c

f n

a t

t o

t r

s i

n n

A o

e

)

r o

o p

s e

e o

u m

i it e

r s

s e

t s

is n

n e

S t

D o

n e

m o

o e

l s

I p

i io gn u

t t

a a

e s

s I

s l

u G

a n

D e

e e

f f

o g

g d

(

l G

i d

n n

b

)

E i

t v

s a

n I

I a

d i

y A

l t

d a

e i

e e

l t

n w

m b

a u

k a

u P

o h

o iM M

V L

lA i

N e

g q

l l

l b

Y r

e i

I n

h e

G a

R N

m I

c t

(

a

)

)

)

)

)

)

u P

m a

b c

d e

f s

a s

)

l m

y p

u a

p o

i w

A g

x o

a h

t P

N n

M a

l t

o a

a A

)

=

)

e 1

2 A

e

(

(

/

S N

7 2

4

&2 -0 1

5 so&

N30 t

in0 U5 t

s 8

n o i

9 oN 9

P t

1 e

n a

iak

,y c

d o M

nD I

eR

=

)

  • m d

e r

io O

O 1

1 r

n 7

y a

E E

E E

d i

9 h M 2

5 3

7 o

3-9 T

r 4

y E

(

1 1

1 1

h t

dn a

y do b

t l

u a

o to tn m

m t

i f

r e

e o

p r

r m

i i

l l

l l

y

)

P s

A m

i i

u m

d m

o a

T 5

4 e

B r

O 1

1 O

f D

E E

-n la a

E E

E E

o A

9 0

t t

o M 2

9 3

7 i

L 6

1 s

T(

2 3

1 1

s 1

1 n

d o

e c

h s

c e

a t

u ta l

n a

o v

e y

h is n

d t

d y

o

)

r o

io e

d s

e t

r

)

e o

B i

u m

i y

d e

m o

h i

S s

B o

s la l

t u

a l

t s

i p

G a

n D

h iq u

a o

a e

e s

d o

T-t L

i T

o T

(

v s

G i

d

(

i u

t s

l a

n s

s d

s d

o y

y n

y e

l l

b a

u a

a I

a i

e a

u s

w o

h or o

w l

o w

iq a

t l

n h

N h

L G

G T

h A

t t

I t

t

)

)

)

)

a e

a a

)

s

)

)

P a

b c

d P

a o

P a

b n

D o

e it g

a a

l r

u e

o v

o

)

A

)

)

P 2

3 1

B.

(

(

(

.C

5

-E E

0 8

D 0

11, O

+

1 1.0 C E 7.0 =

0 I

0 0=I I

=II 1

III P

=

A R YYY T E RRR D

I OOO A L GGG L

P EEE I

TTT C T AAA R

L CCC N U S

H U

M -

R ET N O t

I C T R C U A O

R S F n

7 o

9 i

9 t

1 a

7 t

T 0

S R

+

O E

t P

S n E S S.

i R F o

C 1

T

=

P l

3 N

l n E 0

O a U

+

I i

L E T E

d F 0

A T

n F 0,

L I

I E

U S

1 P

n L

=

O R

o A E E

s U

G T

I i

R E A

d RI H

I H

A L W

E A C

M S

n 2

S E

o P

I 0

R C

I D

5 F

N000000000000000000 N

O000000000000000000 O

C++++++

++++++++++++

C EEEEEEEEEEEEEEEEEEE E

R000000000000000000 R

000000000000000000

)

111111111111111111

)

2Y 2Y

  • D009099800989898989
  • D
  • O010000000000000000
  • O MB+-

- + - - - ++ - - - - - - - - -

HB E/

EEEEEEEEEEEEEEEEEE E/

NIL 000000000000000000 NIL ICA028000700088072231 ICA LPT LPT E(O025078100612231413 E(O R/T R/T O) 009099800989898989 O)

HR 010000000000000000 HR SHN+- - + - - - ++- - - - - - - - -

SHH

/IEEEEEEEEEEEEEEEEEE

/I NK000000000000000000 MK ES068024000114754955 ES R

R H

M

(

026089200523141413 f

775655564556766655 775655564556766655 I000000000000000000 I000000000000000000 L-L - - - - - - - - - - - - - - - - - -

LEEEEEEEEEEEEEnEEEE LEEEEEEEEEEEEEEEEEE 5909102B9047229157 651644693552885203 I064054081105025199 I002132693946154189 G

G 161113412261122271 161113312151322271 6

790606000000005566 790606000000005566 E

000000000000000000 000000000000000000 G-

- +- + - +++++++*- - - -

G-

- + - +- ++++++++ - - - -

NEEEEEEEEEEEEEEEEEE NEEEEEEEEEEEEEEEEEE U530605000000009388 U640002000000009788 L050008000000005213 L010703000000003931 130102000000001121 150104000000002132 706000000975765500 S

706000000975665500 Y010000000000000000 R

Y010000000000000000 S

E-

- - ++++++ - - - - - - - ++

O S E-

- - + +++++ - - - - - - - ++

R NEEEEEEEEEEEEEEEEEE T R ) NEEEEEEEEEEEEEEEEEE S

O)D566000000212519000 C

D696000000201586700 EEI087000000474192000 R

TEI083000000490637700 A

CKK F

CKK W AA 151000000321844300 AA 171000000431156500 C FT E FT A

ND790000000003540099 S

ND790000000S03540099 F

EII000000000000000000 O

EII000000000G00000000 S

O - - +++++++++ - - - ++ - -

D S

O-

- + ++++++++- - - *+ - -

E OIREEEEEEEEEEEEEEEEEE OIREEEEEEEEEEEEEEEEEE S

DCY590000000005030092 I

DCY600000000009660087 O

PH050000000009960078 I

PH000000000003470073 D

N/1 N/T OM 110000000001130061 Y OM 120000000002240082 I

IE R

IE TRY797766663986774567 O

TRY796766663976765567 Y

SMD000000000000000000 G

SHD000000000000000000 R

E(O-E E(O - - - - - - - - - - - - - - - - - -

O G BEEEEEEEEEEEEEEEEEE T G

BEEEEEEEEEEEEEEEEEE G N 562371263691031416 A N 607549300180244910 D E I

L067469730874952112 C

I L061222302514601158 E T A

A Y

A T128413441183171714 T131625661214219515 O C O

O L

T706675660976764488 T706675650976764488 P

000000000000000000 000000000000000000 M *

- +- - - - - - + - - - - - - - - -

- + - - - - - - +- - - - - - - - -

E REEEEEEEEEEEEEEEEEE REEEEEEEEEEEEEEEEEE E507052410685378990 E600827150649017931 L

  • V005940100449444020 V009673820591349417 E

I I

D L104171290315521152 L105291210418731172 O

  • M 000606043976765566 000606043976765466 000000000000000000 000000000000000000 N

+ ++ - +- +- - - - - - - - - - -

+ + + - +- +- - - - - - - - - - -

O EEEEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEEEEEE I

N0005040042b6322709 N000807078255917278 T

O000703038261042987 O000708074208703184 443134A B

B 000000k 000204013614216721 000305014825228132 T

SEEEEEEN 223224223343543122 223224223343543122 W851711E 000000000000000000 000000000000000000 C

R+-

R+-

O975246.N AEEEEEEEEEEEEEEEEEE AEEEEEEEEEEEEEEEEEE LL191637O E20793275B2032B9247 E207932758203289247 O

C Y371778769170282981 Y371778769170282981 F

E

/

/

R E522252322112363114 E522252322112363114 H MH M

I I

R331335L R

R E123333A U

M U

M T111111N C314589030501234745 C314589030501234745 NEEEEER 55555669913333322 55555669913333322 ESTXXXXE 11111111 11111111 C

T E

E RFFFFFFN D RNEOEOIRBG SSBB D

Rl EOEOIRBG SSBB UEEEEEEI IHCMFCFCN5NAI11CCSS IHCmFCFCH5HAIIICCSS OIIIIII L14567E788173335511 L145676788173335511 SRRRRRRO C

22222223445555555 C

22222223445555555 GGGGGGN U

U N

H

N N

O O

C C

E E

R R

)

)

2Y 2Y

  • D
  • D
  • O
  • O HB HB E/

E/

NIL NIL ICA ICA LPT LPT E(O E(

R/T R/%

O)

O)

HR HR SHN SHN

/I

/I MK MK ES ES R

R M

(

M(

776655564556666655 776665564556666655 I000000000000000000 I000000000000000000 L-L - - - - - - - - - - - - - - - - - -

EEEEEEEEEEEEEE LEEEE,58349234357641 LEEEEEEEEEEEEEEEEEE 371 811477751671381104 G

07992635790997 I013195593475709966 I0 G

248112212141122161 347182212131231161 7

790606000000005566 780605000000005556 E

000000000000000000 000000000000000000 G-

- + - + - + + + + ++++ - - - -

G - - + - +- ++++++++- - - -

NEEEEEEEEEEEEEEEEEE NEEEEEEEEEEEEEEEEEE U320504000000007769 U890909000000002442 L000407000000002619 L070305000000004631 290307000000004363 310401000000007617.

S 2

R 796000000975654400 S

796000000865654400 0

O Y000000000000000000 R

Y000000000000000000

+

T S E - - - ++++++ - - - - - - - + +

O S

E-

- - ++++ +- - - - - - - ++

E C

R NEEEEEEEEEEEEEEEEEE T R NEEEEEEEEEEEEEEEEEE 4

A OlD350000000384529200 C

O)D811000000444641400 4

F TEI030000000279221000 A

TEI004000000209718600 2

CKK F

CKK 3

E AA 213000000862211100 AA 324000000114321100 S

FT E

FT 5

O ND790000000003530089 S

ND790000000002430088 D

EII000000000000000000 O

EII000000000000000000 S

S O-

- +++++++++- - - ++- -

D S

O-

- +++++++++ - - - ++- -

I I

OIREEEEEEEEEEEEEEEEEE OIREEEEEEEEEEEEEEEEEE I

DCY340000000002260053 V

DCY800000000009810084 E

I PH090000000007830046 I

PH020000000003530065 S

N/T H/T A

Y OH 240000000005610026 Y

CM 390000000001130051 E

R IE R

IE L

O TRY796665553976765566 O

TRY786665553875665566 E

G SMD000000000000000000 G

SMD000000000000000000 R

E E(O - - - - - - - - - - - - - - - - - -

E E(O - - - - - - - - - - - - - - - - - -

T G

BEEEEEEEEEEEEEEEEEE T G

BEEEEEEEEEEEEEEEEEE L A N 305913633613670290 A N 811082507016030333 A

C I

L098853580298771686 C

I L045491523088231365 T

A A.

T2821611136296284 s1 T314282223141157462 W705665650975664#78 O

T705665550875654477 000000000000000000 000000000000000000

- +- - - - - - + - - - - - - - - -

- +- - - - - - +- - - - - - - - -

REEEEEEEEEEEEEEEEEE REEEEEEEEEEEEEEEEEE E307007980643724342 E809808820373723159 8

V000186280767438145 V009963090722380111 1

I I

L201612520831173315 L301835130174317631 000505042875764456 000505042875654455 S

000000000000000000 000000000000000000 I

+ ++- + - + - - - - - - - - - - -

+ ++- +- + - - - - - - - - - - -

EEEEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEEEEEE M N000505083592024716 N000908045069657243 R

O000106031237093211 O000300032295627212 E

B B

T 000101051251852317 000103061493113521 E

223224223343543122 223224223343543122 C

000000000000000000 000000000000000000 R

R+-

R+-

U AEEEEEEEEEEEEEEEEEE AEEEEEEEEEEEEEEEEEE O E207932758203289247 E207932758203289247 S

Y371778769170282981 Y3717./8769170282981

/

m

/

N E522252322112363114 E522252322112363114 I

I I

R R

R U

H U

H E

C314589030501234745 C314589030501234745 B

55555669913333322 55555669913333322 M

11111111 11111111 U

E E

N D RNE0EOIRBG SSBB D

RNEOEOIRBG SSBB IHCMF0FCN5NAIIICCSS IHCKFCFCH5NAIIICCSS L

L145676788173335511 L145676788173335511 A

C 22222223445555555 C

22222223445555555 T

U U

O N

H T

ll.

I33824663 I33823563 L00010000 L00010000 L-L-

EEEEEEEE

- EEEEEEEE I83975337 I51683132 G60034555 G37031352 44118669 32111167 G34924663 G34923563 N00010000 N00010000 U - - - - - - - -

U-LEEEEEEEE LEEEEEEEE 91005332 03453136 77234554 31031353 27318664 39511165 Y33924662 Y33823562 E00010000 E00010000 3

N-t DEEEEEEEE DEEEEEEEE I07815339 I73383136 K91244550 K12141351 72818661 82111161 2

2 0

0

)

=

E R

)

R E

K O

K O

A T

A T

T D45024663 C

T D45023563 C

l I00110000 A

I00110000 A

l I

O - - - - - - - -

F I

O-F REEEEEEEE REEEEEEEE R

Y79605333 HI R

Y65333134 H

'T A

H22231356 T

A H96434554 E T I

E T

D Y

47418661 I

Y 46511161 I

E W

W L

R E

R E

B E

R E

R 8

A P

O P

O V

H H

E E

M S

M S

I E

E H

R Y23824662 R

Y33823562 M

D00010000 C

H D00010000

(.

(

O - - - - - - - -

O - - - - - - - -

A Y

. BEEEEEEEE

. BEEEEEEEE 42083137 75645338 L

E.

L52964550 E

L96651352 B

S A

S A

A O

T14118662 O

T82111161 N

D O

D O

O T

)

T

)

S R

R A

H H

E (0000000 (0000000 R

E0000000 E0000000 M

M S

R23824662 I5552111 R23823562 I5552111 A

E00010000 T2221 U00010000 T2221 V-1 1

W IEEEEEEEE IEEEEEEEE O

L08435335 S

L96323139 L

36474550 38391351 S

E S

26218663 26311163 A E N

S N

O O

S I0000000 0

I0000000 T

T 0

U5550555 D

U5550555 L

0 L

0 D

I 5

I 5

E23834662 D

E23833562 D

N00010000 I

N00010000 O - - - - - - - -

O-I BEEEEEEEE I

BEEEEEEEE 63025333 67543138 98184556 09091357 Y

15368662 Y

25481162 R

R O

)

O

)

R R

G Y

G Y

/

/

E N

4004 R0000000 E

N 3003 R0800000 H.6 3 0 0 7 0 0 I

0000 H,1 5 0 0 0 0 0 T

K

- ++-

I 0000 T

K

- ++-

S EEEE R2 550 S

EEEE R1 600 A

7007 Y

1 A

2002 Y

11 8008

/

3003

/

C G

C G

K 1001 K

9009

(

(

E E

G G

A A

S S

U U

E E

E E

T T

T T

A A

A A

R E

R E

R E

R E

B GNG B GNG B

GNG B GNG Y

E NING E

NI t G Y

E NING E NING I

A T ILIN T

ILIN A T ILIN T

ILIN W

REKEMIL REKEMI W

REKEMIL REKEMI HHEANRMTA HEANRMT HHEANRMTA HEANRMT TSNGIOIAT SVGIOIA

' SNGIOIAT SV4IOIA I

AI LRHWOO INLRHWO AI ILRHWOO IN1RHWO 1

PF1ADSSBT FIADSSB PFIADSSBT FIADSSB

I34694663 I55925284 L00000000 L00010100 L-L-

- EEEEEEEE EEEEEEEE I07417631 I10557162 G35453255 G29070329 19922362 94935131 G34694663 G45825284 3t00000000 N00010100 U-U-

LEEEEEEEE LEEEEEEEE 50887638 47967162 67353256 47690327 27922363 37135134 Y33594663 Y44825283 E00000000 E00010100 N-N-

DEEEEEEEE DEEEEEEEE I76657630 I23377166 K09283253 K28630320 71222369 81345131 2

2

)

0 E

R E) 0

=

=R K

O K

]

A T

A P

T D45694664 C

T D56925284 C

N I00000000 A

N I00010100 A

I O-F I

O-F REEEEEEEE REEEEEEEE R

Y48087639 H

R Y39377168 H

A H07253250 T

A H12700321 f

f E T D

E T

I Y

45122367 I

Y 66245131 I

W W

R E

R E

E R

E R

F O

P O

9.

H H

E M

S M

S E

E R

Y33594663 R

Y44825284 M

D00000000 M

D00010100 O-O-

(.

BEEEEEEEE

(.. BEEEEEEEE 92657638 11927163 E

L85183256 E

L80210323 S

A S A O

T31222365 O

T21245134 D V

)

D O

T

)

I R

R H

H (0000000 (0000000 E0000000 E0000000 M

M R23594662 I5552111 R34725283 I5552111 E00000000 T2221 E00010100 T2221 S

V-1 V-1 IEEEEEEEE IEEEEEEEE E

L63807632 S

L44667160 13983258 01330328 S

E 26632362 37165133 O

N S

N O

O D

I0000000 O

I0000000 T

T U5550555 D

U5550555 L

0 L

0 I

I 5

I 5

E23494662 D

E34725283 D

I N00000000 V

N00010100 O-O - - - - - - - -

I BEEEEEEEE I

BEEEEEEEE 84207638 68007167 56153253 85650325 Y

27122363 Y

26135133 R

R O

)

O R

R G

Y G

Y

/

/

E N

4004 R9700000 E

N 5005 R5100005 H.6 1 0 0 4 5 0 T

K

- ++-

I 0000 I

0000 H,0 0 0 0 3 0 0 T

K

- ++-

S EEEE R 120 S

EEEE R A

6006 Y

1 A

2002 Y

7007

/

9009

/

C G

C G

K K

2002

(

5005

(

E E

G G

A A

S S

U U

E E

E E

T T

T T

A A

A A

R E

R E

R E

R E

B Gl G B GNG B GNG B GNG l

Y E NING E NING Y E NING E

NING A T ILIN T

ILIN A T ILIN T

ILIN W

REKEMIL REKEMI W

REKEMIL REKEMI HHEANRMTA HEANRMT HHEANRMTA HEANRMT TSNGIOIAT SNGIOIA TSNGIOIAT SVGIOIA AI LRHWOO I

LRHWO AI LRHWOO INLRHWO I

I PFIADSSBT FIADSSB PFIADSSBT FIADSSB

I33914663 I33914663 L00010000 L00010000 L-L-

EEEEEEEE EEEEEEEE I37843662 I94688164 G3,8780668 G39580361 32796446 21798945 G34914663 G34914663 N00010000 N00010000 U-U-

LEEEEEEEE LEEEEEEEE 01803666 62038163 05230661 25296443.

35660368 26398943 Y3390e663 Y33904663 E0001O000 E00010000 N-N - - - - - - - -

DEEEEEEEE DEEEEEEEE I45113660 I49668165 K65900668 K85000362 51516447 51818948 2

2 0

)

R E) 0

=

=

E R

K O

K O

A T

A T

T D45014663 C

T D45014663 C

H I00110000 A

N I00110000 A

F I

O - - - - - - - -

F M EEEEEEE I

E REEEEEEEE l

R Y06213662 H

R Y03638167 H

A H54150660 T

A H04670361 T

E T D

E T D

Y 35396441 I

Y 34398941 I

W W

R E

R E

E R

E R

0 P

O P

O 1

H H

M S

M S

E E

E R

Y23304662 R

Y33804663 M

D00010000

(_

BEEEEEEEE M

D00010000 O - - - - - - - -

O - - - - - - - -

(

E_

BEEEEEEEE 24073668 8743B168 L10410664 E

L38110360 S

A.

S A

N O

T13116441 O

T61118949 I

T

)

D O O

D O T

)

T R

R A

H H

C (0000000 (0000000 O

E0000000 E0000000 L

M M

R23804662 I1119777 R23804662 I1119777 w

E00010000 T3331 E00010000 T3331 V-V-

IEEEEEEEE IEEEEEEEE u

L47443668 S

L00878168 E

67720661 79330362 L

S E

E 14116442 14218942 S

E N

S N

O O

S I0000000 0

I0000000 T

T O

U7777777 D

U7777777 L

L D

I I

E23814662 D

E23814662 D

N00010000 I

N00010000 O - - - - - - - -

O - - - - - - - -

I B E E E E E 's E E I

BEEEEEEEE 06283668 77998168 41280668 42830369 Y

14246441 Y

14268941 R

R O

)

O

)

R R

G Y

G Y

/

/

E N

4004 R0000000 E

N 4004 R0800000 H,1 5 0 0 0 0 0 T

K

- ++-

I 0000 I

0000 H,6 3 0 0 7 0 0 T

K

- ++-

S EEEE R2 550 S

EEEE R1 600 A

5005 Y

1 A

4004 Y

11 M

0000

/

M 4004

/

A C G

A c G

E 7007 K

E 9009 K

R R

T

(

T

(

S E

S E

N G

N G

W A

W A

O S

O S

D U

D U

E E

E E

S T

T S

T T

I A

A I

A A

R E

R E

R E

R E

N B

GNG B GNG N

B GNG B GNG O

Y E NING E

NING O

Y E NING E

NING I

A T ILIN T

ILIN I

A T ILIN T

ILIN T

W REKEMIL REKEMI T

W REKEMIL REKEMI A

HHEANRMTA HEANRMT A HHEANRMTA HEANRMT C

TSNGIOIAT SVGIOIA C

TSNGIOIAT SVGIOIA O

AI LRHWOO INLRHWO O

AI ILRHWOO INLRHWO L

PFIADSSBT FIADSSB L

PFIADSSBT FIADSSB

I44674663 I55905384 L00000000 L00010100 L-L-

- EEEEEEEE

- EEEEEEEE I43309369 I60582137 G28786367 G55466333 96611241 63623921 G45805384 G34674663 t00010100 1

N00000000 U-U-

LEEEEEEEE LEEEEEEEE 00049363 65132137 45286333 35786366.

15611242 25123923 Y33574663 Y44805384 E00010100 E00000000 1

N-DEEEEEEEE DEEEEEEEE 1

I50249365 I71922134 K04606366 K83516335 51121246 51233927 2

2 0

0

)

=

l R

E R

E E

O K

A T

AT D45774664 C

T D56905385 C

H I00000000 A

N I00010100 A

I O-F I

O-F REEEEEEEE REEEEEEEE R

Y49109361 H

R Y93052135 H

A H80496360 T

A H24906333 T

E T D

E T D

Y 24811245 I

Y 44133928 I

W W

R E

R E

1 E

R E

R 1

F O

P O

H H

E M

S M

S E

ER Y33574663 R

Y45805384 M

D00010100 M

D00000000

(

O-O - - - - - - - -

(_

BEEEEEEEE

. BEEEEEEEE 89549366 03442139 E.

L70506360 E

L02696330 S

A S

A O

T21121244 O

T27123923 D V D O

)

)

T W

R H

H( 0000000 (0000000 E0000000 E0000000 M

M R23574662 I1119777 R34805383 I1119777 E00000000 T3331 E00010100 T3331 V-S V-IEEEEEEEE IEEEEEEEE E

L42829362 S

L70952132 11656337 55976360 E

S 25943922 14421242 O

t S

N t

O O

D I0000000 0

I0000000 T

T U7777777 D

U7777777 L

L I

I I

E34705383 D

E23574662 D

! 00000000 V

N00010100 I

!O-O-

I BEEEEEEEE I

BEEEEEEEE 40502135 45399361 07156335 84076364 Y

15811242 Y

24123922 R

R O

)

O

)

P R

G Y

G Y

/

/

i 5005 R5100005 E

N 4004 R9700000 E

t H,0 0 0 0 3 0 0 I

0000 I

0000 H,6 1 0 0 4 5 0 T

K

- ++-

T K

- ++ -

S EEEE R 120 S

EEEE R A

7007 Y

1 A

3003 Y

M 9009

/

M 2002

/

A C G

A C GK E

1001 K

E 4004

(

R R

(

T T

E S

S E

G G

i 11W A

N A

O S

O S

D U

D U

E E

E E

S T

T S

T T

I A

A I

A A

R E

R E

R E

R E

! 1 B GNG H

B Gt G B

G! G G

3 1

a B

G1 O

Y E NI ! G E

NI3 G C Y E NING E

NING t

I A T ILI !

T ILIN 3

I A T ILIN T

ILI1t T

W REKEMIL REKEMI T

W REKEMIL REKEMI P

1 A

HHEAIt RMTA HEANRMT A HHEANRMTA HEANRMT C

TSVGIOIAT SVCIOIA C

TS/GIOIAT SVGIOIA O

AINLRHWOO INLRHWO O AI LRHWOO I! LRHWO L

PFIADaSBT FIADSSB L PFIADSSBT FIADSSB

4 7

0 0+

+

E E

5 5

5 5

1 1

=

=

N N

O 0

O 0

I 0

I 0

T

+

T

+

A E

A E

2342 L

0 2332 L

0 2332 I0000 I0000 U

2 I0000 U

2 L-L-

P L - - - -

P LEEEE O 2

LEEEE O

2 LEEEE

- 9029 P

=

0656 P

m 8790 I0252 V

I7053 V

I8194 G

I G

I

- G 1171 3424 2313 Y

Y R

R 3332 R

O 2332 R

O 2332 G0000 H

G G0000 H

G G0000 N-E 1

E N-1 UEEEE 2

T UEEEE 2

T UEEEE L9860 0

A L0233 0

A L2781 0260

+

C 5585

+

C 9447 E

E 7111 8

2453 0

1342 6

4 2332 1

2222 2

2322 Y0000 0

Y0000 0

Y0000 E - - - -

F 0

E - - - -

F 0

E-I EEEE O

+

NEEEE O

+

NEEEE t

D0826 E

D6253 E

D2997 I0147 E

0 I0157 E

0 I4514 K

K M

2 2

K M

2 5817 S

7119 I

S 2342 I

E

)

T 5

E

)

T 5

)

1 S

M m

S M

=

M E

O E

D4443 G

I O

E D3443 G

I E

D3443 D

R I0000 N

I D

R I0000 N

I R

I0000 O-I O - - - -

I O-N i REEEE S

Y N

N REEEE S Y

N REEEE O

A Y4650 S

R O

A Y5883 S

R A

Y1859 l

I M

H8283 E

O I

M H1971 E

O M

H5162 T

(

T C

G T

(

T C

G

(

T A

9111 O

E A

3354 O

E 2343 L

E R

T L

E R

T E

U S

Y P

A U

S Y P

A S Y P

O D2332 C

P O

D1231 C

O D1331 O

D O0000 D

O D

O0000 D

D O0000 P

B-O P

B-O B-EEEE O EEEE O EEEE NM L8837 F

NM L.0241 F

L7063 OE A9445 OE I4256 A0452 IR T

S 0

IR

- T S

0

- T T-O3324 E

0 T-O1181 E

0 O1961 PN

- T D

+

PN

- T D

+

- T MA U

E MA U

E UM 2322 L

0 UM 1221 L

0 1221 0000 S

0000 C

9 S

0000 C

9 R-N R-N N

R-N O

EEEEE I

6 O

EEEEE I

6 EEEEE 2

=

C V5746 2

=

V8149 C

V4951

)0 I

I0278

)0 I

I5561 I8231 H

L R+

H L

R+

L I

(8 R

I (HE Y

1232 S

5918 HE Y

S 2342 0

R F

E6 O

F E4 O

2322 M

G 1221 M

G 1221 0000 I1 E

0000 I2 E

0000 E-

- - - T T

E-T T

H E-NEEEE NEEEE A

NEEEE A

T O5760 O8319 4

C O5370 5

C B7866 0

A B3130 B9063 0

)

1252 C

+

+

)

H R

1242 C 5" 4817 HE R Y

T -

C0 Y

T1

/

T5 /

R 4334 A

G 7667 A

G O

5445 E0000 C9 K(

G++++

(

P E0000 E0000 C1 K

S G++++

G+++

+

AEEEE AEEEE AEEEE S0740 0

N S9749 0

N S

S5066 U6811 N0 O

U5810 N0 O

E U0464 O+

I T

O+

I D

7869 IE T

S 7869 IE T

U 2212 T0 P

E T0 P

L U0 M

V U0 M

C I

L U

R I

L U

N I

T P

II I7 S

A P

II I7 S

I P

II H

UIII D

N UIII S

UIII D

1!

E O

O O

O E

O V

RYYY C

L RYYY C S S

RYYY R

GRRR A

GRRR E O GRRR A

OOO L

I OOO L

S D

OOO H

EGGGL A

C EGGGL A

O EGGGL GEEEA U

R GEEEA U D A GEEEA T

ATTTT D

E ATTTT D

P AT.TTT R

AAAO I

M AAAO I

A E tAAO O

CCCT V

M CCCT V

P N

CCCT P

N I

O N

I E

S O

D C

O D N L I

N A

I N

T I

T T

I A

A O

Y C

E Y

C E

T Y

A O

G A

O G

A W

L A

W L

A W

HHHHH R

HHHHH R

E HHHHH SSSS E

TSSSS E

T TSSSS

'AIIII V

AIIII V

O AIIII I

PFFFF PFFFF A

PFFFF A

31 w

I lj, 4

7 0

0

+

+

E E

5 7

1 5

1 1

=

=

N rs O

1 O

1 I

0 I

0 T

T A

E A

E 3443 L

0 3443 L

0 34m u I00uO I0000 U

3 I0000 U

3 L-L-

P L-P LEEEE O 3

LEEEE O 3

LEEEE

- - 4829 P

m 4257 P

=

- - 05e3 I6773 V

I6750 V

I 1 2. w.9 G

- G I

G I

4425 2213 5525 Y

Y R

R 4443 R

O 4544 R

O 4443 G0000 H

G G0000 H

G G0000 N-E tI - - - -

E N-UEEEE 2

T UEEEE 2

T UEEEE L1329 0

A L7678 0

A L2941 1323

+

C 9744 0622

+

C E

E 9121 8

5917 0

9121 4

6 S

S E

3443 1

E 3443 2

3443 S

Y0000 1

S Y0000 1

Y0000 O

E-F 0

O E-F 0

E-D NEEEE O D

! EEEE O NEEEE t

D4840 E

D6841 E

D9815 I5965 E

0 N

I4220 E

0 I7328 i

K O

K M

5 O

K M

5 l

I 1232 I

2463 3

I 2353 I

T

)

T 7

T

)

T 7

)

1 A

M

=

A M

=

M L

E D5654 G

I L

E D5665 G

I E

D5554 E

I U

R I0000 N

I R

I0000 U

R I0000 3f P

O-I P

O-I O - - - -

O N REEEE S Y

O N REEEE S Y

N REEEE P

A Y8214 S

R P

A Y9139 S

R A

Y4643 M

H9740 E

O M

H3366 E

O M

H7051 T

(

I' C

C

(

T C

G

(

O 7911 O

E O

4575 O

E 8111 I

E R

T I

E R

T.

E T

S Y

P A

T S Y P

S Y e

P O

D3443 C

P O

D3443 O

D3443 O0000 D

M D

O0000 D

D O0000 r

M D_

B-O U

B-O B-U S

EEEE O EEEE S

EEEE O 3t M L5917 F

L6516 l M L7987 F

oE A9638 OE A8653 A4184 l

CR

_ T S

0 CR T

S 0

- T O4445 E

0 O2223 E

0 O5546 EN

_ T D

+

EH

- T D

+

- T TA U

E TA U

E AH 3332 L

0 AM 3433 L

0 3332 0000 R

0000 C

R 0000 C

0 B

R-l 0

B R-N R-E EEEEE I

1 E

EEEEE I

1 EEEEE l

T V9328 2

s T

V7241

- 2

=

V7509 R

I7280 0

I R

I4002 0

I I5301 E

L

)R+

E L

)R+

L l3 (HE Y

N 4716 (HE Y

8121 V

7111 8

R 0

R I

E6 O

I E4 O

3332 M

G 3433 M

G 3332 0000 I1 E

0000 I2 E

0000 E EEE T T

E-

- - - T T

H E-a EEEE A

C NEEEE NE A

t O2701 4

C o1369 3

C T

O0821 B9127 0

A B5141 B8020 0

)

3635 HE R 7121

+

+ '

C 6121 HE R C0 Y

T0 Y T -

I

/

R T0

/

' 0 3224 A

G 7657 A

G O

3324 G++++

(

G++++

(

P E0000 E0000 C1 E

E0000 C1 K

S G++++

S3870 0

t AEEEE AEEEE AEEEE S0812 0

N S

S7770 U3690 N0 O

U1223 N0 O

E U1061 r

O+

I T

O+

I D

8961 IE T

S 1191 IE T

U 9171 T0 P

E T0 P

U0 M

V U0 M

C I

L U

R I

L U

N I

T P

II I7 1

A P

1I I7 S

I P

II S

S UIII D

H UI1I D

N UIII t

E O

o O

O E

O V

RYYY C

L RYYY C S S

RYYY R

GRRR A

GRRR E

O GRRR A

OOO L

I OOO L S D

OOO H

EGGGL A

C EGGGL A

O EGGGL CEEEA U

R GEEEA U

D A GEEEA T

ATTTT D

E ATTTT D

P ATTTT R

AAAO I

M AAAO I

A E

AAAO O

CCCT V

M CCCT V

P N

CCCT P

N I

O N

I E

S O

D C

O D N L I

N I

N A

T I

T I

T A

A D

Y C

E Y

C E

1 Y

A O

G A

O G

A WRRRR L A

WRRRR L A

WRRRR HEEEE R

HEEEE R

E HEEEE TVNNV E

TNVNN E

T TNVNN 3

N V

A!NI V

0 AtN!

A1 f!

r PIIII A

PIIII A

41 PIIII 1

)

2 YT 0

I

+

L E

I 0

C 6

0100 A

0 3

I1111 F

2 I1 I0 L-

=

L-L -

LEEEE T I

LE LE

- 9210 N

I 0

6 I3044 E

I I4 I3 G

M G

G 5617 T Y 7

4 A R E

O 0009 R

G 9

3 G1110 T E G0 G0 3f - - - -

T f

N-3 UEEEE R A UE UE L179S O C L5 L6 7152 F

2 3

7131 R

1 4

H 9009 4

2 9

3 Y0110 2

0 Y0 Y0 E-

+

E-E-

NEEEE G E NE NE D8547 N

0 D7 D6 6

I7538 I

I8 I3 S

K D

K K

E 1282 U

2 2

4 4

SO M)

L

=

1 C

I D

E D0110 N

I D0 D3 E

R I1111 I

I1 I0 N

O-Y O-O-

O 3

REEEE

(

R RE RE J

I Y0692 R O Y2 Y6 T

M H7929 H G H9 H3 P

(

T E

T T

M 2293 6

T 3

4 U

E 0

A S

S Y

+

C Y

Y N

O D9009 E

D9 D3 O

D O0110 0

O0 O0 C

B-B-

B-0 E

E EEEE R

L9338 1

L8 L6 E

A8530

=

2 A0 A3 T

- T.

E 0

T T

A O3385 M

+

O5 O4 W

T I

E T

T T

0 N

9099 9

3 7

O 0100 T

0 0

I R-I 3

R-R-

T EEEEE S

=

EE EE A

V2740 N

V0 VE L

I0353 A

I I3 I3 U

L R

L L

P 5728 T Y 8

4 O

R P

O 9998 G

8 3

0000 E

0 0

E-T E-E-

NEEEE 2

A NE NE O6239 0

C O9 O6 B7477

+

B7 B3 E

9161 0

)

1 4

R 0

Y 2112 1

/

2 E

0 L

E0 S

E0 E0000

=

(

AE D AE G++++

N G+

O G+

AEEEE O S3688 I

N S8 S0 U6863 I

O U3 M U2 T

I U

t 2243 L T 3

I 2

I P

T D

M I

I U

R P

II S

PL T P

UIII N

UA U

O O

L OT E O RYYY C

A RO R R GRRR 0

T GT E

G OOO 0

L O

H EGGGL

+ A T EL P

EL CEEEA E U

GU S

GA ATTTT 0

D E AM O

AT I

V U

R O

AAAO 0

V I

C D T

CCCT 1

I T

Y

=

D A

H N N L

O I

U R

GGGG I

M G

E YNNNN T E U YN Y

I AIIII A

G C

AI A

L WKKKK L

A WK WR P

HNNNN U R

HN HE P

TIIII P

E TI TT U

ARRRR O V AR AA S

PDDDD P A PD PW

D D

D I

I I

O O

O R1 R3 R4 Y0 Y0 Y0 H -

H-H -

TE TE TE 0

5 3

0 5

7 5

)

1

)

7

)

2 1

M M

M E

E E

E S

P R

P E

Y N Y S

N Y

3t D

A D O

A D A

M O

M O M

O D

(

B1 i

B3

(

B4 E

0 E

0 E

0 N

2 S

L-S L-S L-O I

0 O

AE O AE O

AE T

=

D T0 D T5 D

T3 A

P D0 O5 O7 T

T L

W 1

U S

2 1

7 POP tto IT 1

0 0

A N0 N0 N0 E

I -

I +

I +

R R

KE R

KE R

KE C

H S4 H

S0 H

S0 E

3 0

0 1

1 R

1 0

2 0

0 0

0

+

+

+

E E

E 0

0 0

4 4

4 0

0 0

=

=

=

E E7 E

E7 E

E7 M

G0 M

G0 M

G0 I

A+

I A+

I A+

T SE T

SE T

SE U6 U6 U6 T

6 T

6 T

6 I

I I

S 1

S 1

S!

1 N

IM A

A R

R R

T T

T P

P P

U U

U OL OL OL RU O

RU O

RU GP D

GP D

GP O

2 O

M O

2 EP EP A

EP E

G 0

G 0

G R

1 AL 1

AL 1

AL T

0 A

0 A

0 A

S

+

T

+

T

+

T E

O E

O E

O W

0 T

0 T

0 T

t O

7 7

7 D

0 0

0

- =

1

=

E 1

N 3

II 1

=

G N

F O O YI O O Yt O

C YG I

I AL I

I AI I

I AN T

F WE T T WM T T WI J

HR A U HM A

U HT AC L

TO C L TI C

L TA t

A W' O

I AH O

I AW O

I L D PS L D PS L D P

6 R

1 H

E 0

0

+

E 0

0 4

=E M

I T

T 1010100 I

L0000000 A- + - + - + +

S TEEEEEEE

!A O8412264 R

T7167457 T

5112412 L1041111 A0000000 0

N- +- - - - -

0 REEEEEEE

+

E9663439 E

T2015652 0

X 0

E5183235 RA 7

EY

=

R 3

l E

O P

I L2210100 A

T A0000000 T S U i- - - +- e +

O D L REEEEEEE I

A I

E530'7701 B R D

T8963722 I

M I

O I4712112 T

ES OD E

TARBE T1!

T AO 3

REROr HEAKCCK SVGSCRC It LUAEU I

~

FIAMRHD l

1 1 1 ! ! ! tt t t ! 1 ! t t ! 1 1 ?

7 D642722006211531121 1

I000000000000000000

-E O-

- - - - - + + - - - - - - - - - -

EREEEEEEEEEEEEEEEEEE IY280953703974942321 RH778604404049987006 UT C

649132101129224751 P

i1 1 1 1 t 1 t 1 t 1 ! t 1 t t 1 1 REt Y

MD641322020213530021 EO000000000000000000 RB- - - - - - + - + - - - - - + + - -

EEEEEEEEEEEEEEEEEE HL271830957582979231 AA795973465449931706 MT O643738132124222151 T

t t t t I 1 t 1 1 t t t ! t ! t 1 t !

S D354936209553063143 1

I I000000000000100000 0

S O-

- - - - - - + - - - - - - - - - -

Y REEEEEEEEEEEEEEEEEE E L

Y793255506312165532 7

A H521778502220695327 N ET 0

A S

312416504142911196 2

O T D I

F M t1 ! 1 ! ! t t ! 1 t ! 1 t t ! 1 1 1 E EY J

RD354435243556063143 1

E O000000000000100000 0

B NB- - - - - - - - - - - - - - - - - -

)

A EEEEEEEEEEEEEEEEEE E R

T ML741344387319132152 7

E))

S A536213666629662327 1

DDD LLL O

T OOO)

C O317222597149917396 4

T D

RSSL

!1 1 t ? t 1 ? t t t I 1 ! ! 1 1 ! 1 ORRO AA DEER 223224223343543122 LYYA E

000000000000000000 O

E SR+-

71Y AYEEEEEEEEEEEEEEEEEE S11 E/207932758203289247 R

1 LI371778769170282981 AOO EC

ETTO R

522252322112363114 P

Y T

U 11 O

71(O t5 1 t tI 1 t ! 1 t t 11 1 1 t! t R

1(

(

G

(

I M

E IIV 314589030501234745 G

IIII E

55555669913333322 A

D 11111111 YYYY I

L N

RRRR L

RNEOEOIPBG SSBB A O

OOOO C

HCHFCFCNSNAIIICCSS T

GGGG U

145676788173335S11 O

E EEEE N

22222223445555S55 T

T TTTT O AAAA N CCCC

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

A i

l i

1 VD SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

l FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL 1

l N

.0

.0 6.0 1.0

.0

.0

.0 7.0 1

NNE

.0

.0

.0

.0

.0

.0

.0

. 0, NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 5.0 5.0

.0

.0

.0 10.0 S

.0

.0 1.0 4.0

.0

.0

.0 5.0 SSW

.0

.0 2.0 2.0

.0

.0

.0 4.0 SW

.0

.0 1.0

.0

.0

.0

.0 1.0 WSW

.0

.0 2.0 2.0

.0

.0

.0 4.0 W

.0

.0 4.0 3.0

.0

.0

.0 7.0 vani

.0

.0 12.0 14.0 1.0

.0

.0 27.0

{

NW

.0

.0 10.0 26.0

.0

.0

.0 36.0

)

NNW

.0

.0 11.0 2.0

.0

.0

.0 13.0 TOTAL

.0

.0 54.0 59.0 1.0

.0

.0 114.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 l

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l l

E-18

i l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 l

BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

I (1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

1 l

PASQUILL STAB'ILITY :

B j

l WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL s

N

.0

.0 6.0 4.0

.0

.0

.0 10.0 NNE

.0

.0

.0

.0

.0

.0

.0

,.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 l

i i

E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0 1.0

.0

.0

.0

.0 1.0 SSE

.0

.0 3.0

.0

.0

.0

.0 3.0 S

.0

.0 2.0 4.0 0

.0

.0 6.0

}

SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0 1.0

.0

.0

.0

.0 1.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0 4.0 2.0

.0

.0

.0 6.0 WNW

.0

.0 2.0 8.0 2.0

.0

.0 12.0 NW

.0

.0 12.0 12.0

.0

.0

.0 24.0 NNW

.0

.0 9.0 1.0

.0

.0

.0 10.0 1

TOTAL

.0

.0 40.0 31.0 2.0

.0

.0 73.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 7

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 l

l 1

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l f

E-19

l

)

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 i

i BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23) 1

{

PASQUILL STABILITY:

C j

l WIND SPEED (MPH)

)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 10.0 2.0

.0

.0

.0 12.0 J

NNE

.0

.0 3.0 1.0

.0

.0

.0 4.0 j

NE

.0

.0

.0

.0

.0

.0

.0

.0 J

ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 6.0 1.0

.0

.0

.0 7.0 S

.0

.0 10.0 6.0

.0

.0

.0 16.0 SSW

.0

.0 2.0

.0 1.0

.0

.0 3.0 SW

.0

.0 2.0 1.0

.0

.0

.0 3.0 WSW

.0

.0 4.0

.0

.0

.0

.0 4.0 W

.0

.0 3.0 3.0

.0

.0

.0 6.0 WNW

.0

.0 5.0 9.0 2.0

.0

.0 16.0 NW 0

.0 11.0 9.0

.0

.0

.0 20.0 i

NNW

.0

.0 5.0

.0

.0

.0

.0 5.0 s

TOTAL

.0

.0 61.0 32.0 3.0

.0

.C 96.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-20

3 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

[1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.7 11.0 72.0 52.0 9.0

.0

.0 144.7 NNE

.8 12.0 92.0 21.0 1.0

.0

.0 126.8 NE

.8 12.0 12.0

.0

.0

.0

.0 24.8 ENE

.5 8.0

.0

.0

.0

.0

.0 8.5 E

.6 9.0 3.0

.0

.0

.0

.0 12.6 ESE

.4 6.0 1.0

.0

.0

.0

.0 7.4 SE

.6 9.0 7.0

.0

.0

.0

.0 16.6 SSE

.6 9.0 43.0 11.0

.0

.0

.0 63.6 S

1.9 30.0 57.0 28.0 1.0

.0

.0 117.9 SSW 1.0 15.0 25.0 7.0 2.0

.0

.0 50.0 SW

.4 6.0 12.0 1.0 1.0

.0

.0 20.4 WSW

.7 11.0 20.0 7.0

.0

.0

.0 38.7 W

.5 8.0 36.0 13.0 1.0

.0

.0 58.5 WNW

.6 10.0 79.0 47.0 5.0

.0

.0 141.6 NW

.5 7.0 107.0 95.0 6.0

.0

.0 21E.5 NNW

.5 8.0 79.0 45.0

.0

.0

.0 132.5 TOTAL 11.0 171.0 645.0 327.0 26.0

.0

.0 1180.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 1

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 j

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-21

INDIAN POINT (UNITS 2 & 3). JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 l

l BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

[1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

{

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.3 25.0 20.0

.0

.0

.0

.0 45.3 NNE

.3 25.0 30.0 1.0

.0

.0

.0 56.3 NE

.2 17.0 9.0

.0

.0

.0

.0 26.2 ENE

.1 10.0 1.0

.0

.0

.0

.0 11.1 E

.2 12.0

.0

.0

.0

.0

.0 l' '

ESE

.1 8.0

.0

.0

.0

.0

.0 8.1 SE

.1 11.0 2.0

.0

.0

.0

.0 13.1 SSE

.5 37.0 35.0

.0

.0

.0

.0 72.5 S

.6 49.0 69.0 21.0

.0

.0

.0 139.6 SSW

.4 31.0 12.0 6.0

.0

.0

.0 49.4 SW

.3 27.0 6.0

.0

.0

.0

.0 33.3 WSW

.2 17.0 4.0 1.0

.0

.0

.0 22.2 W

.2 13.0 12.0 7.0 2.0

.0

.0 34.2 WNW

.1 7.0 14.0 6.0 1.0

.0

.0 28.1 NW

.1 8.0 5.0 3.0

.0

.0

.0 16.1 NNW

.2 16.0 5.0

.0

.0

.0

.0 21.2 TOTAL 4.0 313.0 224.0 45.0 3.0

.0

.0 589.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E 22

I INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day /Hourl (1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 4.0

.0

.0

.0

.0

.0 4.0 l

NNE

.0 10.0 9.0

.0

.0

.0

.0 19.0 NE

.0 7.0 6.0

.0

.0

.0

.0 13.0 ENE

.0 5.0

.0

.0

.0

.0

.0 5.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0 3.0

.0

.0

.0

.0

.0 3.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 5.0 1.0

.0

.0

.0

.0 6.0 S

.0 7.0 3.0

.0

.0

.0

.0 10.0 SSW

.0 5.0 1.0

.0

.0

.0

.0 6.0 SW

.0 2.0 1.0

.0

.0

.0

.0 3.0 WSW

.0 3.0 1.0

.0

.0

.0

.0 4.0 W

.0 3.0

.0

.0

.0

.0

.0 3.0 WNW

.0 3.0

.0

.0

.0

.0

.0 3.0 NW

.0 1.0

.0

.0

.0

.0

.0 1.0 NNW

.0 1.0

.0

.0

.0

.0

.0 1.0 TOTAL

.0 59.0 22.0

.0

.0

.0

.0 81.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-23 i

t i

l 1

I l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (lM)

FOR PERIOD (Year / Month / Day / Hour]

[1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 4.0 2.0

.0

.0

.0

.0 6.0 NNE

.0 6.0 1.0

.0

.0

.0

.0 7.0

'E

.0 1.0 2.0

.0

.0

.0

.0 3.0 N

ENE

.0

.0

.0

.0

.0

.0

.0

.0 1

E

.0 1.0

.0

.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 1.0

.0

.0

.0

.0

.0 1.0 S

.0 1.0

.0

.0

.0

.0

.0 1.0 SSW

.0 2.0

.0

.0

.0

.0

.0 2.0 SW 0

2.0

.0

.0

.0

.0

.0 2.0 WSW

.0 1.0

.0

.0

.0

.0

.0 1.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0 1.0

.0

.0

.0

.0

.0 1.0 NNW

.0 1.0 1.0

.0

.0

.0

.0 2.0 TOTAL

.0 21.0 6.0

.0

.0

.0

.0 27.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY, l

E-24

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

1.0 44.0 116.0 59.0 9.0

.0

.0 229.0 NNE 1.1 53.0 135.0 23.0 1.0

.0

.0 213.1 NE 1.0 37.0 29.0

.0

.0

.0

.0 67.0 ENE

.6 23.0 1.0

.C

.0

.0

.0 24.6 E

.7 22.0 3.0

.0

.0

.0

.0 25.7 ESE

.5 17.0 1.0

.0

.0

.0

.0 18.5 SE 7

20.0 10.0

.0

.0

.0

.0 30.7 SSE 1.1 52.0 93.0 17.0

.0

.0

.0 163.1 S

2.6 87.0 142.0 63.0 1.0

.0

.0 295.6 SSW 1.4 53.0 42,0 15.0 3.0

.0

.0 114.4 SW

.7 37.0 23.0 2.0 1.0

.0

.0 63.7 WSW

.9 32.0 31.0 10.0

.0

.0

.0 73.9 W

.7 24.0 59.0 28.0 3.0

.0

.0 114.7 WNW

.7 20.0 112.0 84.0 11.0

.0

.0 227.7 NW

.6 17.0 145.0 145.0 6.0

.0

.0 313.6 NNW

.7 26.0 110.0 48.0

.0

.0

.0 184.7 TOTAL 15.0 564.0 1052.0 494.0 35.0

.0

.0 2160.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-25

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0}

TO (1997/ 3/?l/23]

PASQUILL STABILITY:

A WIND SPEED (MPH) j WIND

.60 -

3.50.

7.50 -

12.50 -

18.50 -

24.00 -

f 4

i FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 1.0 5.0 2.0

.0

.0 8.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0 5.0 3.0

.0

.0 8.0 S

.0

.0

.0 4.0 2.0

.0

.0 6.0 SSW

.0

.0

.0 2.0 3.0

.0

.0 5.0 SW

.0

.0 1.0

.0

.0

.0

.0 1.0 WSW

.0

.0 1.0 1.0 2.0

.0

.0 4.0 W

.0

.0

.0 4.0 3.0

.0

.0 7.0 WNW

.0

.0 1.0 4.0 6.0 5.0 1.0 17.0 NW

.0

.0 1.0 8.0 16.0 15.0 3.0 43.0 NNW

.0

.0 1.0 7.0 4.0 2.0 1.0 15.0 TOTAL

.0

.0 6.0 40.0 41.0 22.0 5.0 114.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-26

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0 7.0 1.0 2.0

.0 10.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0 1.0

.0

.0

.0 1.0 SSE

.0

.0 2.0 2.0

.0

.0

.0 4.0 S

.0

.0

.0

.0 3.0

.0

.0 3.0 SSW

.0

.0

.0 1.0 1.0

.0

.0 2.0 SW

.0

.0 1.0

.0

.0

.0

.0 1.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0 2.0 1.0 3.0

.0

.0 6.0 WNW

.0

.0

.0 1.0 6.0 2.0 2.0 11.0 NW

.0

.0

.0 6.0 14.0 4.0 4.0 28.0 NNW

.0

.0 2.0 4.0 1.0

.0

.0 7.0 TOTAL

.0

.0 7.0 23.0 29.0 8.0 6.0 73.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E 27

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

[1997/ 1/ 1/ 0]

TO

[1997/ 3/31/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 4.0 8.0 1.0 1.0

.0 14.0 NNE

.0

.0

.0 2.0

.0

.0

.0 2.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 4.0 2.0 1.0

.0

.0 7.0 S

.0

.0 7.0 5.0 1.0

.0

.0 13.0 SSW

.0

.0 2.0 1.0 1.C 1.0 1.0 6.0 SW

.0

.0

.0 1.0 2.0

.0

.0 3.0 WSW

.0

.0

.0 2.0 2.0

.0

.0 4.0 W

.0

.0

.0 1.0 3.0 1.0

.0 5.0 WNW

.0

.0 2.0 2.0 8.0 4.0 2.0 18.0 NW

.0

.0

.0 5.0 6.0 5.0 2.0 18.0 NNW

.0

.0 2.0 2.0 2.0

.0

.0 6.0 TOTAL

.0

.0 21.0 31.0 27.0 12.0 5.0 96.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160

)

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E.28

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

{

f FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 4.0 23.0 46.0 57.0 15.0 11.0 156.0 NNE

.0 3.0 51.0 48.0 4.0 1.0

.0 107.0 NE

.0 3.0 17.0 4.0

.0

.0

.0 24.0 ENE

.0 7.0 5.0

.0

.0

.0

.0 12.0 E

.0 3.0 9.0 1.0

.o

.0

.0 13.0 ESE

.0 1.0 12.9 3.0

.0

.0

.0 16.0 SE

.0 1.0 8.o 7.0

.0

.0

.0 16.0 SSE

.0 5.0 24.0 29.0 8.0

.0

.0 66.0 S

.0 13.0 30.0 33.0 11.0 1.0

.0 88.0 SSW

.0 6.0 23.0 12.0 12.0 4.0

.0 57.0 SW

.0 5.0 7.0 13.0 2.0 3.0 2.0 32.0 WSW

.0 3.0 5.0 12.0 16.0 4.0 2.0 42.0 I

W

.0 2.0 10.0 12.0 23.0 7.0 2.0 56.0 I

f WNW

.0 1.0 13.0 36.0 65.0 12.0 5.0 132.0 NW

.0 1.0 9.0 53.0 109.0 49.0 13.0 234.0 j

NNW

.0 3.0 10.0 46.0 47.0 20.0 3.0 129.0 TOTAL

.0 61.0 256.0 355.0 334.0 116.0 38.0 1180.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 1

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PFP.IOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E.29

I INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTI'NS - JAN/FEB/ MAR 1997 i

BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M) l FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

l PASQUILL STABILITY:

E WIND SPEED (MPH) j j

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 8.0 19.0 10.0 3.0

.0

.0 40.0 NNE

.0 13.0 29.0 15.0

.0

.0

.0 57.0 NE

.0 3.0 7.0 1.0

.0

.0

.0 11.0 ENE

.0 1.0 4.0

.0

.0

.0

.0 5.0 E

.0 4.0 3.0

.0

.0

.0

.0 7.0 ESE

.0 4.0 5.0 1.0

.0

.0

.0 10.0 SE

.0 7.0 8.0 1.0

.0

.0

.0 16.0 SSE

.0 10.0 26.0 21.0 1.0

.0

.0 58.0 S

.0 12.0 59.0 49.0 25.0

.0

.0 145.0 SSW

.0 13.0 27.0 25.0 12.0

.0

.0 77.0 SW

.0 4.0 18.0 6.0 7.0 3.0

.0 38.0 WSW

.0 7.0 7.0 6.0 4.0

.0 1.0 25.0 W

.0 5.0 5.0 3.0 6.0 2.0 4.0 25.0 WNW

.0 1.0 11.0 13.0 1.0 3.0 4.0 33.0 NW

.0 5.0 7.0 11.0 2.0 1.0 1.0 27.0 NNW

.0 2.0 7.0 4.0 2.0

.0

.0 15.0 TOTAL

.0 99.0 242.0 166.0 63.0 9.0 10.0 589.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SE:!SOR SEPARATION (METERS) 50.90 MISSINC OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTIC i TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GkOUP WIT 9 NON-ZERO ENTRIES IN EACH STABILITY.

F-30

I INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M) i l

FOR PERIOD [ Year / Month / Day / Hour)

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

i PASQUILL STABILITY:

F i

WIND SPEED (MPH) f WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 6.0 5.0

.0

.0

.0

.0 11.0 NNE

.0

.0 10.0 7.0

.0

.0

.0 17.0 NE

.0 1.0 1.0

.0

.0

.0

.0 2.0 ENE

.0

.0 1.0

.0

.0

.0

.0 1.0 E

.0 1.0

.0

.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0 2.0

.0

.0

.0

.0 2.0 SSE

.0 1.0 5.0

.0

.0

.0

.0 6.0 S

.0 1.0 8.0 3.0 1.0

.0

.0 13.0 SSW

.0

.0 5.0 7.0

.0

.0

.0 12.0 SW

.0 1.0 3.0 1.0

.0

.0

.0 5.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0 1.0

.0 1.0

.0

.0

.0 2.0 WNW

.0 1.0 1.0 1.0

.0

.0

.0 3.0 NW

.0 4.0

.0 1.0

.0

.0

.0 5.0 i

NNW

.0

.0 1.0

.0

.0

.0

.0 1.0 f

TOTAL

.0 17.0 42.0 21.0 1.0

.0

.0 81.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-31

1 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 1

BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 4.0 1.0

.0

.0

.0

.0 5.0 NNE

.0

.0 2.0 1.0

.0

.0

.0 3.0 NE

.0 1.0

.0

.0

.0

.0

.0 1.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0

.0

.0

.0

.0

.0 S

.0

.0 2.0 3.0

.0

.0

.0 5.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0 1.0

.0

.0

.0 1.0 WSW

.0

.0 3.0

.0

.0

.0

.0 3.0 W

.0

.0 1.0

.0

.0

.0

.0 1.0 WNW

.0 1.0 1.0

.0

.0

.0

.0 2.0 NW

.0

.0 1.0

.0

.0

.0

.0 1.0 NNW

.0

.0 1.0 3.0

.0

.0

.0 4.0 l

TOTAL

.0 7.0 12.0 8.0

.0

.0

.0 27.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEFARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZJ O ENTRIES IN EACH STABILITY.

E 32

INDIAN POINT (UNITS 2 & 3). JOINT FREQUENCY DISTRIBUTIONS - JAN/FES/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 22.0 53.0 76.0 64.0 18.0 11.0 244.0 NNE

.0 16.0 92.0 73.0 4.0 1.0

.0 186.0, NE

.0 8.0 25.0 5.0

.0

.0

.0 38.0 ENE

.0 9.0 10.0

.0

.0

.0

.0 19.0 E

.0 8.0 12.0 1.0

.0

.0

.0 21.0 ESE

.0 5.0 17.0 4.0

.0

.0

.0 26.0 SE

.0 8.0 18.0 9.0

.0

.0

.0 35.0 SSE

.0 16.0 61.0 59.0 13.0

.0

.0 149.0 S

.0 26.0 106.0 97.0 43.0 1.0

.0 273.0 SSW

.0 19.0 57.0 48.0 29.0 5.0 1.0 159.0 SW

.0 10.0 30.0 22.0 11.0 6.0 2.0 81.0 WSW

.0 10.0 16.0 21.0 24.0 4.0 3.0 78.0 W

.0 8.0 18.0 22.0 38,0 10.0 6.0 102.0 WNW

.0 4.0 29.0 57.0 86.0 26.0 14.0 216.0 NW

.0 10.0 18.0 84.0 147.0 74.0 23.0 356.0 NNW

.0 5.0 24.0 66.0 56.0 22.0 4.0 177.0 TOTAL

.0 184.0 586.0 644.0 515.0 167.0 64.0 2160.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOUEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-33 1

I INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 l

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M) l FOR PERIOD [ Year / Month / Day / Hour]

[1997/ 1/ 1/ 0]

TO

[1997/ 3/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0

.0

.0

.0

.0

.0 NNE

.0

.0 2.0 1.0

.0

.0

.0 3.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 J

SSE

.0

.0

.0

.0

.0

.0

.0

.0 S

.0

.0 1.0

.0

.0

.0

.0 1.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0

.0

.0

.0

.0 1.0

.0 1.0 NNW

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0

.0 3.0 1.0

.0 1.0

.0 5.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

i l

E-34

i INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 I

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M) l FOR PERIOD { Year / Month / Day / Hour) l (1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH) i

{

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0 1.0

.0

.0 3.0 4.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0 1.0 3.0

.0

.0 4.0 S

.0

.0 3.0 2.0

.0

.0

.0 5.0 SSW

.0

.0

.0 1.0 1.0 1.0

.0 3.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0 0

.0

.0

.0 W

.0 1.0

.0

.0

.0

.0

.0 1.0 WNW

.0

.0

.0 1.0 1.0 1.0

.0 3.0 NW

.0

.0

.0 2.0 3.0 3.0 2.0 10.0 NNW

.0

.0

.0 1.0 3

.0

.0 1.0 TOTAL

.0 1.0 3.0 9.0 8.0 5.0 5.0 31.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-35

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 1.0 6.0 2.0

.0 2.0 11.0 NNE

.0 1.0

.0

.0

.0

.0

.0 1.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0 3.0

.0

.0

.0

.0 3.0 SE

.0

.0 2.0

.0

.0

.0

.0 2.0 SSE

.0

.0 2.0 1.0

.0

.0

.0 3.0 S

.0 1.0 2.0 2.0 1.0

.0

.0 6.0 SSW

.0

.0 1.0 6.0 1.0

.0

.0 8.0 SW

.0

.0 1.0

.0

.0

.0

.0 1.0 WSW

.0

.0 1.0

.0 2.0

.0

.0 3.0 W

.0

.0

.0 4.0 2.0 1.0

.0 7.0 WNW

.0

.0 1.0 3.0 5.0 4.0 4.0 17.0 NW

.0

.0 1.0 3.0 9.0 8.0 2.0 23.0 tiNW

.0

.0 1.0 5.0 4.0 2.0 1.0 13.0 TOTAL

.0 2.0 16.0 30.0 26.0 15.0 9.0 98.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILIT11S) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l E-36

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour)

(1997/ 1/ 1/ 0]

TO

[1997/ 3/31/22]

)

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 4.0 15.0 53.0 56.0 25.0 14.0 167.0 NNE

.0 5.0 36.0 56.0 8.0 3.0

.0 108.0 NE

.0 2.0 14.0 20.0

.0

.0

.0 36.0 ENE

.0 3.0 10.0 3.0

.0

.0

.0 16.0 E

.0 3.0 8.0 3.0

.0

.0

.0 14.0 1

ESE

.0 1.0 11.0 13.0 2.0

.0

.0 27.0 SE

.0 6.0 9.0 18.0 2.0

.0

.0 35.0 SSE

.0 6.0 18.0 29.0 16.0 3.0

.0 72.0 1

S

.0 3.0 39.0 54.0 25.0 4.0

.0 125.0 SSW

.0 4.0 16.0 17.0 28.0 8.0 4.0 77.0 SW

.0 4.0 7.0 13.0 6.0 6.0 3.0 39.0 WSW

.0 5.0 6.0 9.0 28.0 7.0 2.0 57.0 W

.0 2.0 8.0 18.0 33.0 15.0 10.0 86.0 WNW

.0

.0 10.0 47.0 77.0 45.0 21.0 200.0 NW

.0

.0 16.0 55.0 132.0 85.0 41.0 329.0 NNW

.0 3.0 10.0 37.0 45.0 21.0 7.0 123.0 TOTAL

.0 51.0 233.0 445.0 458.0 222.0 102.0 1511.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 i

l NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E.37

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M) l FOR PERIOD [ Year / Month / Day / Hour]

l (1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH) l WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 18.0 10.0 1.0

.0

.0 29.0 NNE

.0 3.0

.3.0 11.0 2.0

.0

.0 19.0 NE

.0 2.0 10.0 3.0

.0

.0

.0 15.0 ENE

.0 2.0 2.0

.0

.0

.0

.0 4.0 E

.0 1.0 7.0 2.0

.0

.0

.0 10.0 ESE

.0 5.0 5.0 1.0

.0

.0

.0 11.0 SE

.0 3.0 6.0 2.0

.0

.0

.0 11.0 SSE

.0 5.0 18.0 9.0 5.0

.0

.0 37.0 S

.0 6.0 35.0 52.0 39.0 8.0

.0 140.0 SSW

.0 4.0 17.0 24.0 15.0 3.0

.0 63.0 SW

.0 5.0 9.0 13.0 3.0 6.0

.0 36.0 WSW

.0 4.0 15.0 6.0 2.0 1.0 1.0 29.0 W

.0

.0 7.0 7.0 1.0 3.0 3.0 21.0 WNW 0

1.0 4.0 2.0

.0 1.0

.0 8.0 NW

.0 1.0 3.0 5.0 2.0

.0

.0 11.0 NNW

.0 3.0 7.0 3.0

.0

.0

.0 13.0 TOTAL

.0 45.0 166.0 150.0 70.0 22.0 4.0 457.0 1

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-38

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day /Hourl (1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 2.0 3.0 1.0

.0

.0

.0 6.0 4.0

.0

.0

.0

.0 4.0 NNE

.0

.0 NE

.0 2.0 2.0 2.0

.0

.0

.0 6.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0 1.0 1.0

.0

.0

.0

.0 2.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 i

SE

.0

.0

.0

.0

.0

.0

.0

.0 f

SSE

.0

.0

.0 2.0

.0

.0

.0 2.0 I

i S

.0

.0

.0 3.0 5.0

.0

.0 8.0 SSW

.0 1.0

.0 1.0 5.0

.0

.0 7.0 SW

.0 1.0 1.0

.0

.0

.0

.0 2.0 WSW

.0

.0

.0 1.0

.0

.0

.0 1.0 W

.0 1.0 1.0 1.0

.0

.0

.0 3.0 WNW

.0 1.0 2.0 1.0

.0

.0

.0 4.0 NW

.0 2.0 1.0 3.0 1.0

.0

.0 7.0 NNW

.0

.0 1.0 1.0 1.0

.0

.0 3.0 TOTAL

.0 11.0 16.0 16.0 12.0

.0

.0 55.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-39

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS. JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 1/ 1/ 0]

TO (1997/ 3/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FRCM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0

.0

.0

.0

.0

.0 NNE

.0

.0 1.0

.0

.0

.0

.0 1.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

,0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0

.0

.0

.0

.0

.0 S

.0

.0

.0

.0 1.0

.0

.0 1.0 SSW 0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0 1.0

.0

.0

.0

.0 1.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0

.0

.0

.0

.0

.0

.0

.0 NNW

.0

.0

.0

.0

.0

.0

.0

.0 l

TOTAL

.0

.0 2.0

.0 1.0

.0

.0 3.0 DATA MEASUREMENT HFIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. D'JRING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-40

l l

i INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JAN/FEB/ MAR 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M) l FOR PERIOD [ Year / Month / Day / Hour)

)

(1997/ 1/ 1/ 0)

TO (1997/ 3/31/23]

I PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL 4

N

.0 6.0 37.0 71.0 59.0 25.0 19.0 217.0 NNE

.0 9.0 46,0 68.0 10.0 3.0

.0 136.0

)

NE

.0 6.0 26.0 25.0

.0

.0

.0 57.0 ENE

.0 5.0 12.0 3.0

.0

.0

.0 20.0 E

.0 5.0 16.0 5.0

.0

.0

.0 26.0 ESE

.0 6.0 19.0 14.0 2.0

.0

.0 41.0 SE

.0 9.0 17.0 20.0 2.0

.0

.0 48.0 SSE

.0 11.0 38.0 42.0 24.0 3.0

.0 118.0 S

.0 10.9 80.0 113.0 71.0 12.0

.0 286.0 SSW

.0 9.0 34.0 49.0 50.0 12.0 4.0 158.0 SW

.0 10.0 18.0 26.0 9.0 12.0 3.0 78.0 WSW

.0 9.0 22.0 16.0 32.0 8.0 3.0 90.0 i

1 W

.0 4.0 17.0 30.0 36.0 19.0 13.0 119.0 WNW

.0 2.0 17.0 54.0 83.0 51.0 25.0 232.0 NW

.0 3.0 21.0 68.0 147.0 97.0 45.0 381.0 1RD4

.0 6.0 19.0 47.0 50.0 23.0 8.0 153.0 TOTAL

.0 110.0 439.0 651.0 575.0 265.0 120.0 2160.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 0 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2160 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-41

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

l PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 31.0 12.0

.0

.0

.0 43.0 NME

.0

.0

.0 2.0

.0

.0

.0 2.0 NE

.0

.0 2.0

.0

.0

.0

.0 2.0 ENE

.0

.0 2.0

.0

.0

.0

.0 2.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 1

SSE

.0

.0 28.0 13.0

.0

.0

.0 41.0 S

.0

.0 32.0 13.0 3.0

.0

.0 48.0 SSW

.0

.0 3.0 7.0 1.0

.0

.0 11.0 SW

.0

.0 5,0 1.0

.0

.C

.0 6.0 WSW

.0

.0 11.0 1.0

.0

.0

.0 12.0 W

.0

.0 9.0 6.0

.0

.0

.0 15.0 WNW

.0

.0 22.0 19.0

.0

.0

.0 41.0 NW

.0

.0 15.0 41.0

.0

.0

.0 56.0 NNW

.0

.0 21.0 24.0

.0

.0

.0 45.0 TOTAL

.0

.0 181.0 139.0 4.0

.0

.0 324.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E42

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour}

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL 4

N

.0 1.0 10.0 7.0

.0

.0

.0 18.0 10.0 4.0

.0

.0

.0 14.0 NNE

.0

.0 NE

.0

.0 1.0 1.0

.0

.0

.0 2.0 ENE

.0

.0 4.0

.0

.0

.0

.0 4.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0 1.0

.0

.0

.0

.0

.0 1.0 SSE

.0 2.0 9.0 1.0

.0

.0

.0 12.0 S

.0 2.0 22.0 3.0

.0

.0

.0 27.0 SSW

.0 1.0 3.0 1.0

.0

.0

.0 5.0 SW

.0

.0 5.0

.0

.0

.0

.0 5.0 WSW

.0 0

3.0 1.0

.0

.0

.0 4.0 W

.0

.0 4.0 2.0

.0

.0

.0 6.0 WNW

.0

.0 7.0 5.0

.0

.0

.0 12.0 NW

.0

.0 7.0 7.0

.0

.0

.0 14.0 NNW

.0

.0 5.0 2.0 1.0

.0

.0 8.0

(

1 TOTAL

.0 7.0 90.0 34.0 1.0

.0

.0 132.0 DATA MEASUREMENT HEIGHT (M ABOVE GR\\DE) 10.00 l

f TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-43 l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL

)

N

.0 1.0 16.0 2.0 4.0

.0

.0 23.0 NNE

.0

.0 12.0 9.0

.0

.0

.0 21.0 NE

.0 1.0 2.0 1.0

.0

.0

.0 4.0 ENE

.0 1.0 1.0

.0

.0

.0

.0 2.0 E

.0 1.0

.0

.0

.0

.0

.0 1.0 ESE

.0

.0 1.0

.0

.0

.0

.0 1.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 1.0 5.0 3.0

.0

.0

.0 9.0 S

.0 2.0 20.0 4.0

.0

.0

.0 26.0 SSW

.0 1.0 9.0 3.0 1.0

.0

.0 14.0 SW

.0 2.0 6.0 1.0

.0

.0

.0 9.0 WSW

.0 4.0

.0

.0

.0

.0

.0 4.0 W

.0

.0 3.0 1.0

.0

.0

.0 4.0 WNW

.0 1.0 7.0 3.0 1.0

.0

.0 12.0 NW

.0

.0 4.0 7.0

.0

.0

.0 11.0 NNW

.0 2.0 4.0 6.0

.0

.0

.0 12.0 TOTAL

.0 17.0 90.0 40.0 6.0

.0

.0 153.0 DATA MEASUREMENT HEIGHT (M sOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-44

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

l l

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 14.0 48.0 11.0 3.0 2.0

.0 78.0

'NNE

.0 20.0 55.0 24.0

.0

.0

.0 99.0 NE

.0 7.0 14.0 2.0

.0

.0

.0 23.0 ENE

.0 5.0

.0

.0

.0

.0

.0 5.0 E

.0 7.0 1.0

.0

.0

.0

.0 8.0 ESE

.0 9.0 1.0

.0

.0

.0

.0 10.0 SE

.0 11.0 1.0

.0

.0

.0

.0 12.0 SSE

.0 25.0 80.0 8.0

.0

.0

.0 113.0 S

.0 21.0 76.0 12.0

.0

.0

.0 109.0 SSW

.0 8.0 19.0 9.0

.0

.0

.0 36.0 l

SW

.0 9.0 12.0

.0

.0

.0

.0 21.0 WSW

.0 8.0 6.0

.0

.0

.0

.0 14.0 W

.0 9.0 23.0 4.0

.0

.0

.0 36.0 WNW

.0 6.0 48.0 17.0

.0

.0

.0 71.0 NW

.0 7.0 61.0 25.0

.0

.0

.0 93.0 NNW

.0 12.0 41.0 44.0 3.0

.0

.0 100.0 l

TOTAL

.0 178.0 486.0 156.0 6.0 2.0

.0 828.0 i

)

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180

)

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l E-45

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO

[1997/ 6/30/23]

PASQUILL STABILITY:

E 1

l WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18J50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL i

N

.0 22.0 14.0 3.0 5.0

.0

.0 44.0 NNE

.0 38.0 44.0

.0

.0

.0

.0 82.0 NE

.0 24.0 13.0

.0

.0

.0

.0 37.0 ENE

.0 17.0

.0

.0

.0

.0

.0 17.0 l

E

.0 14.0 1.0

.0

.0

.0

.0 15.0 ESE

.0 10.0

.0

.0

.0

.0

.0 10.0 SE

.0 15.0 1.0

.0

.0

.0

.0 16.0 SSE

.0 47.0 26.0 3.0

.0

.0

.0 76.0 S

.0 46.0 31.0 3.0

.0

.0

.0 80.0 SSW

.0 26.0 15.0 3.0

.0

.0

.0 44.0 SW

.0 12.0 3.0

.0

.0

.0

.0 15.0 WSW

.0 10.0 2.0

.0

.0

.0

.0 12.0 W

.0 14.0 9.0 1.0

.0

.0

.0 24.0 l

WNW

.0 5.0 11.0 1.0

.0

.0

.0 17.0 NW

.0 9.0 7.0

.0

.0

.0

.0 16.0 NNW

.0 2.0 14.0

.0

.0

.0

.0 16.0 TOTAL

.0 311.0 191.0 14.0 5.0

.0

.0 521.0 P

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 l

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-46

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00

  • 0TAL N

.0 25.0 3.0

.0

.0

.0

.0 28.0 NNE

.0 28.0 18.0

.0

.0

.0

.0 46.0 NE

.0 19.0 8.0

.0

.0

.0

.0 27.0 ENE

.0 5.0

.0

.0

.0

.0

.0 5.0 E

.0 6.0

.0

.0

.0

.0

.0 6.0 ESE

.0 5.0

.0

.0

.0

.0

.0 5.0 SE

.0 3.0

.0

.0

.0

.0

.0 3.0 SSE

.0 8.0 3.0

.0

.0

.0

.0 11.0 i

S

.0 11.0

.0

.0

.0

.0

.0 11.0 SSW

.0 5.0

.0

.0

.0

.0

.0 5.0 SW

.0 6.0

.0

.0

.0

.0

.0 6.0 WSW

.0 4.0

.0

.0

.0

.0

.0 4.0 W

.0 5.0

.0

.0

.0

.0

.0 5.0 WNW

.0 2.0

.0

.0

.0

.0

.0 2.0 NW

.0 5.0

.0

.0

.0

.0

.0 5.0 NNW

.0 10.0 1.0

.0

.0

.0

.0 11.0 l

TOTAL

.0 147.0 33.0

.0

.0

.0

.0 180.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TJ THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-47

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUEMCY DISTRIBUTIONS - APR/MAY/JUN 1997 1

BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 4/ 1/ 0)

TO (1997/ 6/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

]

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 10.0

.0

.0

.0

.0

.0 10.0 NNE

.0 5.0 7.0

.0

.0

.0

.0 12.0 NE

.0 2.0 3.0

.0

.0

.0

.0 5.0 ENE

.0 4.0 1.0

.0

.0

.0

.0 5.0 E

.0 1.0 1.0

.0

.0

.0

.0 2.0 ESE

.0 1.0

.0

.0

.0

.0

.0 1.0 SE

.0 2.0

.0

.0

.0

.0

.0 2.0 SSE

.0

.0

.0

.0

.0

.0

.0

.0

{

S

.0 2.0

.0

.0

.0

.0

.0 2.0 SSW

.0

.0 1.0

.0

.0

.0

.0 1.0 SW

.0 2.0

.0

.0

.0

.0

.0 2.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0

.0

.0

.0

.0

.0

.0

.0 NNW

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0 29.0 13.0

.0

.0

.0

.0 42.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E.48

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour)

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 73.0 122.0 35.0 12.0 2.0

.0 244.0 NNE

.0 91.0 146.0 39.0

.0

.0

.0 276.0 NE

.0 53.0 43.0 4.0

.0

.0

.0 100.0 ENE

.0 32.0 8.0

.0

.0

.0

.0 40.0 E

.0 29.0 3.0

.0

.0

.0

.0 32.0 ESE

.0 25.0 2.0

.0

.0

.0

.0 27.0 SE

.0 32.0 2.0

.0

.0

.0

.0 34.0 SSE

.0 83.0 151.0 28.0

.0

.0

.0 262.0 S

.0 84.0 181.0 35.0 3.0

.0

.0 303.0 SSW

.0 41.0 50.0 23.0 2.0

.0

.0 116.0 SW

.0 31.0 31.0 2.0

.0

.0

.0 64.0 WSW

.0 26.0 22.0 2.0

.0

.0

.0 50.0 l

W

.0 28.0 48.0 14.0

.0

.0

.0 90.0 WNW

.0 14.0 95.0 45.0 1.0

.0

.0 155.0 NW

.0 21.0 94.0 80.0

.0

.0

.0 195.0 NNW

.0 26.0 86.0 76.0 4.0

.0

.0 192.0 TOTAL

.0 689.0 1084.0 383.0 22.0 2.0

.0 2180.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OSS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-49

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTICNS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 2.0 20.0 8.0 4.0

.0 34.0 NNE

.0

.0

.0

.0 1.0

.0

.0 1.0 NE

.0

.0 1.0 1.0

.0

.0

.0 2.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0 2.0

.0

.0

.0 2.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0 3.0

.0

.0

.0 3.0 SSE

.0

.0 17.0 28.0 12.0 1.0

.0 58.0 S

.0

.0 7.0 15.0 3.0

.0

.0 25.0 SSW

.0

.0

.0 1.0 3.0 3.0 2.0 9.0 SW

.0

.0 1.0 2.0

.0 3.0

.0 6.0 WSW

.0

.0 2.0 6.0

.0 1.0 1.0 10.0 W

.0

.0

.0 10.0 6.0 3.0

.0 19.0 WNW

.0

.0 1.0 14.0 9.0 10.0 4.0 38.0 NW

.0

.0 5.0 4.0 25.0 25.0 11.0 70.0 bnN

.0

.0

.0 11.0 24.0 10.0 2.0 47.0 TOTAL

.0

.0 36.0 117.0 91.0 60.0 20.0 324.0 i

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 i

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

1

}

I E 50 I

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

[1997/-4/ 1/ 0]

TO

[1997/ 6/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 1.0 9.0 2.0 2.0 2.0 16.0 NNE

.0

.0 3.0 3.0

.0

.0

.0 6.0 NE

.0

.0 2.0 4.0

.0

.0

.0 6.0 ENE

.0

.0

.0 1.0

.0

.0

.0 1.0 E

.0

.0 1.0 2.0

.0

.0

.0 3.0 ESE

.0

.0 1.0

,0

.0

.0

.0 1.0 SE

.0

.0 1.0

.0

.0

.0

.0 1.0 SSE

.0

.0 11.0 10.0 1.0

.0

.0 22.0 S

.0

.0 12.0 2.0

.0

.0

.0 14.0 SSW

.0

.0 1.0 2.0 2.0

.0

.0 5.0 SW

.0

.0 4.0

.0

.0

.0

.0 4.0 WSW

.0

.0 3.0 1.0 2.0 2.0

.0 8.0 W

.0

.0

.0 3,0 1.0

.0

.0 4.0 WNW

.0

.0

.0 4.0 3.0 4.0 2.0 13.0 NW

.0

.0 4.0 2.0 4.0 5.0

.0 15.0 NNW

.0

.0 3.0 1.0 6.0

.0 3.0 13.0 TOTAL

.0

.0 47.0 44.0 21.0 13.0 7.0 132.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-51

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

[1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 4.0 8.0 2.0 1.0 5.0 20.0 NNE

.0

.0 6.0 4.0 4.0

.0

.0 14.0 NE

.0

.0 1.0 5.0

.0

.0

.0 6.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 E

.0

.0

.0 1.0

.0

.0

.0 1.0 ESE

.0

.0 1,0

.0

.0

.0

.0 1.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 7.0 4.0 3.0

.0

.0 14.0 S

.0

.0 9.0 5.0 1.0

.0

.0 15.0 SSW

.0

.0 10.0 2.0 4.0 1.0

.0 17.0 SW

.0

.0 7.0 1.0 2.0

.0

.0 10.0 WSW

.0 1.0 2.0 1.0

.0

.0

.0 4.0 W

.0

.0 4.0 2.0 1.0

.0

.0 7.0 WNW

.0

.0 3.0

.0 5.0 4.0 1.0 13.0 NW

.0

.0 2.0 2.0 5.0 4.0 2.0 15.0 NNW

.0

.0 5.0 3.0 4.0 1.0 2.0 15.0 TOTAL

.0 2.0 61.0 38.0 31.0 11.0 10.0 153.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E.52 i

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUEN(Y DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 5.0 22.0 16.0 20.0 11.0 7.0 81.0 NNE

.0 13.0 17.0 32.0 10.0

.0

.0 72.0 NE

.0 8.0 10.0 15.0 2.0

.0

.0 35.0 ENE

.0 8.0

.0

.0

.0

.0

.0 8.0 E

.0 1.0 5.0

.0

.0

.0

.0 6.0 ESE

.0 5.0 9.0 1.0

.0

.0

.0 15.0 SE

.0 4.0 8.0 3.0

.0

.0

.0 15.0

)

SSE

.0 15.0 45.0 64.0 13.0

.0

.0 137.0 S

.0 11.0 39.0 30.0 7.0 1.0

.0 88.0 SSW

.0 6.0 7.0 5.0 9.0 1.0

.0 28.0 SW

.0 3.0 5.0 6.0 5.0

.0

.0 19.0 WSW

.0 3.0 3.0 7.0 2.0

.0

.0 15.0 W

.0 1.0 5.0 10.0 4.0 2.0 1.0 23.0 WNW

.0 1.0 4.0 20.0 32.0 16.0

.0 73.0 NW

.0 5.0 4.0 28.0 60.0 21.0 2.0 120.0 NNW

.0 3.0 3.0 18.0 34.0 28.0 7.0 93.0 TOTAL

.0 92.0 186.0 255.0 198.0 80.0 17.0 828.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO l

ENTRIES IN EACH STABILITY.

t I

E-53 l

1 i

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 I

BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL j

j N

.0 4.0 21.0 10.0 2.0 3.0 3.0 43.0 NNE

.0 10.0 56.0 20.0

.0

.0

.0 86.0 NE

.0 4.0 12.0 3.0

.0

.0

.0 19.0

{

ENE

.0 6.0 2.0

.0

.0

.0 0

8.0 E

.0 4.0 2.0

.0

.0

.0

.0 6.0 ESE

.0 7.0

.0

.0

.0

.0

.0 7.0 SE

.0 7.0 12.0 1.0

.0

.0

.0 20.0 SSE

.0 9.0 46.0 28.0 3.0

.0

.0 86.0 S

.0 9.0 34.0 20.0 5.0

.0

.0 68,0 SSW

.0 9.0 12.0 20.0 4.0 1.0

.0 46.0 SW

.0 6.0 7.0 9.0 1.0 1.0

.0 24.0 WSW

.0 4.0 5.0 3.0

.0

.0

.0 12.0 W

.0 1.0 5.0 7.0 4.0

.0

.0 17.0 RNW

.0 1.0 6.0 9.0 10.0

.0

.0 26.0 NW

.0

.0 6.0 19.0 8.0

.0

.0 33.0 NNW

.0 3.0 6.0 8.0 3.0

.0

.0 20.0 TOTAL

.0 84.0 232.0 157.0 40.0 5.0 3.0 521.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

j E-54

)

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

l

[1997/ 4/ 1/ 0]

TO

[1997/ C/30/23]

i PASQUILL STABILITY:

F l

WIND SPEED (MPH)

)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

)

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 8.0 18.0 2.0

.0

.0

.0 28.0 NNE

.0 7.0 21.0 6.0

.0

.0

.0 34.0 NE

.0 5.0 3.0

.0

.0

.0

.0 8.0 ENE

.0 5.0 1.0

.0

.0

.0

.0 6.0 E

.0 2.0

.0

.0

.0

.0

.0 2.0 ESE

.0 2.0 1.0

.0

.0

.0

.0 3.0 SE

.0 1.0

.0

.0

.0

.0

.0 1.0 SSE

.0 4.0 3.0

.0

.0

.0

.0 7.0 S

.0 3.0 6.0 7.0

.0

.0

.0 16.0 SSW

.0 3.0 10.0 3.0

.0

.0

.0 16.0 SW

.0 10.0 7.0 1.0

.0

.0

.0 18.0 WSW

.0 4.0 1.0

.0

.0

.0

.0 5.0 W

.0 4.0 2.0

.0

.0

.0

.0 6.0 WNW

.0 5.0

.0 2.0 1.0

.0

.0 8.0 NW

.0 3.0 1.0 7,0

.0

.0

.0 11.0 NNW

.0 4.0 4.0 3;0

.0

.0

.0 11.0

{

i l

TOTAL

.0 70.0 78.0 31.0 1.0

.0

.0 180.0 l

i DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-55 l

I l

t

(

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 1.0 5.0 1.0

.0

.0

.0 7.0 NME

.0 3.0 4.0 1.0

.0

.0

.0 8.0 NE

.0 3.0

.0

.0

.0

.0

.0 3.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0 1.0

.0

.0

.0

.0

.0 1.0 l

SSE

.0

.0

.0

.0

.0

.0

.0

.0 I

i l

S

.0 2.0 2.0 2.0 1.0

.0

.0 7.0 SSW

.0 2.0 1.0

.0

.0

.0

.0 3.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0 1.0

.0

.0

.0

.0

.0 1.0 W

.0 2.0 2.0

.0

.0

.0

.0 4.0 WNW

.0

.0 1.0

.0

.0

.0

.0 1.0 NW

.0 1.0

.0

.0

.0

.0

.0 1.0 1RGi

.0 1.0 3.0 1.0

.0

.0

.0 5.0 l

TOTAL

.0 18.0 18.0 5.0 1.0

.0

.0 42.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 k

i NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY

]

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO I

ENTRIES IN EACH STABILITY.

l E-5'6 i

)

I INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 j

BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 18.0 73.0 66.0 34.0 21.0 17.0 229.0 NNE

.0 33.0 107.0 66.0 15.0

.0

.0 221.0 NE

.0 20.0 29.0 28.0 2.0

.0

.0 79.0 ENE

.0 21.0 3.0 1.0

.0

.0

.0 25.0 E

.0 7.0 8.0 5.0

.0

.0

.0 20.0 ESE

.0 14.0 12.0 1.0

.0

.0

.0 27.0 SE

.0 13.0 21.0 7.0

.0

,0

.0 41.0 SSE

.0 28.0 129.0 134.0 32.0 1.0

.0 324.0 S

.0 25.0 109.0 81.0 17.0 1.0

.0 233.0 SSW

.0 20.0 41.0 33.0 22.0 6.0 2.0 124.0 SW

.0 19.0 31.0 19.0 8.0 4.0

.0 81.0 WSW

.0 13.0 16.0 18 J 4.0 3.0 1.0 55.0 W

.0 8.0 18.0 32.0 16.0 5.0 1.0 80.0 WNW

.0 7.0 15.0 49.0 60.0 34.0 7.0 172.0 NW

.0 9.0 22.0 62.0 102.0 55.0 15.0 265.0 1RN

.0 11.0 24.0 45.0 71.0 39.0 14.0 204.0 TOTAL

.0 266.0 658.0 647.0 383.0 169.0 57.0 2180.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER, DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l E-57

INDIAN POINT (UNITS 2 t, 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 199">

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

[1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12. 5

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 1r. 50 24.00 80.00 TOTAL N

.0

.0

.0 1.0

.0

.0 6.0 7.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.C

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.c

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0 1.0

.0

.0

.0 1.0 SSE

.0

.0

.0 4.0 4.0

.0

.0 8.0 S

.0

.0

.0

.0

.0

.0

.0

.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0

)

'dSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0

.0 1.0

.0

.0 1.0 WNW

.0

.0

.0 2.0 1.0 2.0

.0 5.0 NW

.0

.0

.0

.0 1.0 2.0 2.0 5.0 NNW

.0

.0

.0

.0

.0 1.0

.0 1.0 i

TOTAL

.0

.0

.0 8.0 7.0 5.0 8.0 28.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALTr OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 i

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY f

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO I

ENTRIES IN EACH STABILITY.

E-58 l

IL

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour}

[1997/ 4/ 1/ 0)

TO (1997/ 6/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0 3.0 8.0 5.0 2.0 18.0 NNE

.0

.0

.0

.0

,0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0 1.0

.0

.0

.0 1.0 SSF

.0

.0 2.0 11.0 6.0 1.0

.0 20.0 l

S

.0

.0

.0 3.0 2.0

.0

.0 5.0 SSW

.0

.0

.0

.0 1.0

.0 2.0 3.0 SW

.0

.0

.0 2.0

.0

.0

.0 2.0 WSW

.0

.0

.0 1.0 2.0

.0

.0 3.0 W

.0

.0

.0 2.0 4.0

.0

.0 6.0 WNW

.0

.0

.0 3.0 7.0 3.0 4.0 17.0 NW

.0

.0 1.0 2.0 6.0 13.0 5.0 27.0 FR&.'

.0

.0

.0 2.0 14.0 4.0 1.0 21.0 TOTAL

.0

.0 3.0 30.0 50.0 26.0 14.0 123.0 DATA MEASUREMEN'I' HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSCR SEPARATION (METERS) 112.00 l

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

I l

E-59 1

I l

INDIAN POINT (UNITS 2 r. 3 ) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

' 19 PERIOD (Year / Month / Day / Hour)

F (1997/ 4/ 1/ 0]

TO

[1997/ 6/30/231 1

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL 1

I N

.0

.0

.0 17.0 7.0 3.0

.0 27.0 l

NUE

.0

.0 2.0 4.0

.0 1.0

.0 7.0 NE

.0

.0 3.0 3.0

.0

.0

.0 6.0 ENE

.0

.0

.0 2.0 1.0

.0

.0 3.0 E

.0

.0 1.0 2.0

.0

.0

.0 3.0 j

ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0 1.0

.0

.0

.0 1.0 SSE

.0

.0 13.0 16.0 5.0 1.0

.0 35.0 S

.0

.0 3.0 5.0 2.0

.0

.0 10.0 SSW

.0

.0

.0

.0 1,0 1.0 3.0 5.0 SW

.0

.0 1.0 1.0

.0 3.0

.0 5.0 WSW

.0

.0 1.0 3.0 1.0

.0 2.0 7.0 W

.0

.0 1.C 6.0 1.0 3.0 2.0 13.0 WNW

.0

.0 1.0 5.0 3.0 7.0 6.0 22.0 NW

.0

.0 5.0 5.0 7.0 15.0 11.0 43.0 NNW

.0

.0 4.0 2.0 8.0 4.0 1.0 19.0 TOTAL

.0

.0 35.0 72.0 36.0 38.0 25.0 206.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-60

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 3.0 21.0 35.0 29.0 12.0 20.0 120.0 NNE

.0 4.0 19.0 22.0 23.0

.0

.0 68.0 NE

.0 8.0 11.0 20.0 12.0

.0

.0 51.0 ENE

.0 6.0 6.0

.0

.0 1.0

.0 13.0 E

.0 6.0 2.0 3.0

.0

.0

.0 11.0 ESE

.0 3.0 11.0 1.0

.0

.0

.0 15.0 SE

.0 8.0 13.0 8.0 3.0

.0

.0 32.0 SSE

.0 12.0 63.0 65.0 48.0 5.0

.0 193.0 S

.0 6.0 44.0 51.0 15.0 3.0

.0 119.0 SSW

.0 5.0 16.0 15.0 15.0 7.0 1.0 59.0 SW

.0 2.0 8.0 6.0 6.0 5.0

.0 27.0 WSW

.0 3.0 5.0 6.0 5.0 1.0 1.0 21.0 W

.0 1.0 4.0 12.0 16.0 9.0 2.0 44.0 WNW

.0 2.0 11.0 18.0 43.0 37.0 6.0 117.0 NW

.0 3.0 8.0 16.0 83.0 42.0 13.0 165.0 NNW

.0 3.0 9.0 21.0 35.0 35.0 22.0 125.0 TOTAL

.0 75.0 251.0 299.0 333.0 157.0 65.0 1180.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-61

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO

{1997/ 6/30/23]

PASQUILL STABILITY:

E j

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 - 24 00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 4.0 18.0 15.0 3.0

.0

.0 40.0 NNE

.0 3.0 19.0 12.0 3.0

.0

.0 37.0 NE

.0 6.0 6.0 4.0

.0

.0

.0 16.0 ENE

.0 6.0 4.0

.0

.0

.0

.0 10.0 E

.0 8.0 2.0 1.0

.0

.0

.0 11.0 ESE

.0 7,0 2.0

.0

.0

.0

.0 9.0 SE

.0 7.0 4.0

.0

.0

.0

.0 11.0 SSE

.0 9.0 26.0 27.0 2.0 2.0

.0 66.0 S

.0 9.0 40.0 28.0 7.0 2.0

.0 86.0 SSW

.0 15.0 18.0 32.0 8.0 1.0

.0 74.0 SW

.0 4.0 15.0 8.0 3.0 1.0 1.0 32.0 WSW

.0 5.0 7.0 4.0 1.0

.0

.0 17.0 W

.0 3.0 7.0 7.0 2.0

.0

.0 19.0 WNW

.0

.0 2.0 4.0 6.0

.0

.0 12.0 NW

.0 3.0 9.0 17.0 7.0 1.0

.0 37.0 1RDi

.0 5.0 11.0 9.0 5.0

.0

.0 30.0 TOTAL

.0 94.0 190.0 168.0 47.0 7.0 1.0 507.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY, E.62

INMLN POINT ', UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIOUS - APR/MAY/JUN 1997 l

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.1 4.0 13.0 7.0

.0

.0

.0 24.1 NNE

.0

.0 2.0 2.0

.0

.0

.0 4.0 NE

.0 1.0

.0

.0

.0

.0

.0 1.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 E

.0 1.0 1.0

.0

.0

.0

.0 2.0 ESE

.0 1.0 2.0

.0

.0

.0

.0 3.0 1

SE

.1 6.0 1.0

.0

.0

.0

.0 7.1 SSE

.1 5.0

.0

.0

.0

.0

.0 5.1 S

.1 6.0 7.0

.0 1.0

.0

.0 14.1 SSW

.1 6.0 3.0 2.0 3.0

.0

.0 14.1 SW

.2 8.0 4.0

.0

.0

.0

.0 12.2 WSW

.1 4.0 1.0 2.0

.0

.0

.0 7.1 W

.0 1.0

.0 1.0

.0

.0

.0 2.0 WNW

.0 1.0 2.0 1.0

.0 1.0

.0 5.0 1

NW

.1 3.0 3.0 2.0 2.0

.0

.0 10.1

!aN

.1 4.0 12.0 4.0 1.0

.0

.0 21.1 TOTAL 1.0 52.0 51.0 21.0 7.0 1.0

.0 133.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 1

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-63

i l

l l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 I

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO

[1997/ 6/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 - 12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0

.0

.0

.0

.0

.0 NNE.

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.G

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 S

.0

.0

.0

.0

.0

.0

.0

.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0 1.0 2.0

.0

.0

.0 3.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0

.0

.0

.0

.0

.0

.0

.0 NNW

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0

.0 1.0 2.0

.0

.0

.0 3.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E.64

t INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - APR/MAY/JUN 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 4/ 1/ 0]

TO (1997/ 6/30/23]

i PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.1 11.0 52.0 78.0 47.0 20.0 28.0 236.1 NNE

.0 7.0 42,0 40.0 26.0 1.0

.0 116.0 NE

.0 15.0 20.0 27.0 12.0

.0

.0 74.0 ENE

.0 13.0 10.0 2.0 1.0 1.0

.0 27.0 E

.0 15.0 6.0 6.0

.0

.0

.0 27.0 ESE

.0 11.0 15.0 1.0

.0

.0

.0 27.0 SE

.1 21.0 18.0 11.0 3.0

.0

.0 53.1 SSE

.1 26.0 104.0 123.0 65.0 9.0

.0 327.1 S

.1 21.0 94.0 87.0 27.0 5.0

.0 234.1 SSW

.1 26.0 37.0 49.0 28.0 9.0 6.0 155.1 SW

.2 14.0 28.0 17.0 9.0 9.0 1.0 78.2 WSW

.1 12.0 14.0 16.0 9.0 1.0 3.0 55.1 W

.0 5.0 13.0 30.0 24.0 12.0 4.0 88.0 WNW

.0 3.0 16.0 33.0 60.0 50.0 16.0 178.0 NW

.1 9.0 26.0 42.0 106.0 73.0 31.0 287.1 NNW

.1 12.0 36.0 38.0 63.0 44.0 24.0 217.1 TOTAL 1.0 221.0 531.0 600.0 480.0 234.0 113.0 2180.0 l

l l

l l

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 I

TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 4 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2180 l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO l

ENTRIES IN EACH STABILITY, I

i 1

E-65 i

1 l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 l

l BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour)

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

A i

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50.

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 52.0 13.0

.0

.0

.0 65.0 NNE

.0

.0 3.0 3.0

.0

.0

.0 6.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENS

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 19.0

.0

.0

.0

.0 19.0 S

.0

.0 44.0 12.0

.0

.0

.0 56.0 SSW

.0

.0 9.0 2.0

.0

.0

.0 11.0 SW

.0

.0 15.0

.0

.0

.0

.0 15.0 WSW

.0 1.0 9.0

.0

.0

.0

.0 10.0 W

.0

.0 15.0

.0

.0

.0

.0 15.0 WNW

.0 1.0 11.0 1.0

.0

.0

.0 13.0 NW

.0

.0 7.0 2.0

.0

.0

.0 9.0 NNW

.0

.0 21.0 2.0

.0

.0

.0 23.0 TOTAL

.0 2.0 205.0 35.0

.0

.0

.0 242.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-66

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/A*IG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH) 18.50 -

24.00 -

WIND

.60 -

3.50 -

7.50 -

12.50 FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 30.0 6.0

.0

.0

.0 36.0 NNE

.0

.0 7.0 3.0

.0

.0

.0 10.0 WE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 1.0 8.0 1.0

.0

.0

.0 10.0 S

.0 3.0 30.0 6.0

.0

.0

.0 39.0 SSW

.0 1.0 9.0 2.0

.0

.0

.0 12.0 SW

.0

.0 12.0 1.0

.0

.0

.0 13.0 WSW

.0

.0 7.0

.0

.0

.0

.0 7.0 W

.0 2.0 8.0

.0

.0

.0

.0 10.0 l

WNW

.0 1.0 1.0

.0

.0

.0

.G 2.0 NW

.0 2.0

.0

.0

.0

.0

.3 2.0 NNW

.0

.0 3.0

.0

.0

.0

.0 3.0 TOTAL

.0 10.0 115.0 19.0

.0

.0

.0 144.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-67

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS. JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/./ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH) j WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL

{

N

.0 2.0 37.0 2.0

.0

.0

.0 41.0 NNE

.0 2.0 15.0 1.0

.0

.0

.0 18.0 NE

.0 0

3.0

.0

.0

.0

.0 3.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0 1.0

.0

.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0 1.0

.0

.0

.0

.0 1.0 SSE

.0 4.0 5.0

.0

.0

.0

.0 9.0 S

.0 9.0 17.0 1.0

.0

.0

.0 27.0 SSW

.0 3.0 8.0 1.0

.0

.0

.0 12.0 SW

.0

.0 9.0 1.0

.0

.0

.0 10.0 WSW

.0 1.0 8.0

.0

.0

.0

.0 9.0 W

.0 2.0 2.0 1.0

.0

.0

.0 5.0 WNW

.0 3.0 1.0

.0

.0

.0

.0 4.0 NW

.0 1.0 2.0

.0

.0

.0

.0 3.0 NNW

.0 1.0 4.0

.0

.0

.0

.0 5.0 TOTAL

.0 29.0 112.0 7.0

.0

.0

.0 148.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (NLL STABILITIES) 80

)

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 l

)

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY i

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

1 E 68

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 16.0 92.C 8.0

.0

.0

.0 116.0

.0 170.0 NNE

.0 21.0 110.0 39.0

.0

.0 NE

.0 19.0 33.0

.0

.0

.0

.0 52.0 ENE

.0 24.0 13.0

.0

.0

.0

.0 37.0 f

E

.0 14.0 8.0

.0

.0

.0

.0 22,0 ESE

.0 15.0 2.0

.0

.0

.0

.0 17.0 SE

.0 12.0

.0

.0

.0

.0

.0 12.0 SSE

.0 17.0 36.0

.0

.0

.0

.0 53.0 3

.0 32.0 71.0 13.0

.0

.0

.0 116.0 bSW

.0 18.0 21.0 4.0

.0

.0

.0 43.0 SW

.0 14.0 10.0

.0

.0

.0

.0 24.0 WSW

.0 12.0 11.0 3.0

.0

.0

.0 26.0 W

.0 4.0 10.0

.0

.0

.0

.0 14.0 WNW

.0 8.0 4.0

.0

.0

.0

.0 12.0 NW

.0 2.0 2.0 1.0

.0

.0

.0 5.0 NNW

.0 6.0 11.0 1.0

.0

.0

.0 18.0 TOTAL

.0 234.0 434.0 69.0

.0

.0

.0 737.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-69

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS. JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

l (1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

I WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00.

FROM CALMS 3.50 7,50 12.50 18.50 24.00 80.00 TOTAL N

.1 23.0 3.0 1.0

.0

.0

.0 27.1 NNE

.1 58.0 89.0 1.0

.0

.0

.0 148.1 NE

.1 44.0 48.0

.0

.0

.0

.0 92.1 ENE

.1 21.0 6.0

.0

.0

.0

.0 27.1 E

.1 25.0

.0

.0

.0

.0

.0 25.1 ESE

.0 17.0 1.0

.0

.0

.0

.0 18.0 SE

.0 17.0

.0

.0

.0

.0

.0 17.0 SSE

.1 23.0 10.0

.0

.0

.0

.0 33.1 S

.1 56.0 47.0 6.0

.0

.0

.0 109.1 SSW

.1 45.0 22.0

.0

.0

.0

.0 67.1 SW

.0 18.0 2.0 1.0

.0

.0

.0 21.0 WSW

.0 18.0 4.0 1.0

.0

.0

.0 23.0 W

.0 6.0 5.0

.0

.0

.0

.0 11.0 WNW

.0 4.0 3.0

.0

.0

.0

.0 7.0 NW

.0 7.0 2.0

.0

.0

.0

.0 9.0 NNW

.0 18.0 2.0

.0

.0

.0

.0 20.0 D

TOTAL 1.0 400.0 244,0 10.0

.0

.0

.0 655.0

)

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 j

TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 l

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY l

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO I

ENTRIES IN EACH STABILITY.

t l

l E-70

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour)

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

l l

l PASQUILL STABILITY:

F WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 20.0

.0

.0

.0

.0

.0 20.0 NNE

.0 26.0 20.0

.0

.0

.0

.0 46.0 NE

.0 22.0 11.0

.0

.0

.0

.0 33.0 ENE

.0 13.0 2.0

.0

.0

.0

.0 15.0 E

.0 15.0 1.0

.0

.0

.0

.0 16.0 ESE

.0 11.0

.0

.0

.0

.0

.0 11.0 SE

.0 11.0

.0

.0

.0

.0

.0 11.0 SSE

.0 8.0

.0

.0

.0

.0

.0 8.0 S

.0 11.0

.0

.0

.0

.0

.0 11.0 SSW

.0 7.0

.0

.0

.0

.0

.0 7.0 SW

.0 5.0

.0

.0

.0

.0

.0 5.0 WSW

.0 1.0

.0

.0

.0

.0

.0 1.0 W

.0 4.0

.0

.0

.0

.0

.0 4.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0 3.0

.0

.0

.0

.0

.0 3.0 NNW

.0 4.0

.0

.0

.0

.0 0

4.0 TOTAL

.0 161.0 34.0

.0

.0

.0

.0 195.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 1

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 i

i VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LCWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

i 1

i l

l l

E-71 l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

[1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0

.0

.0

.0

.0

.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0 2.0

.0

.0

.0

.0

.0 2.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 E

.0 2.0

.0

.0

.0

.0

.0 2.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0

.0

.0

.0

.0

.0 S

.0

.0

.0

.0

.0

.0

.0

.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0 1.0

.0

.0

.0

.0

.0 1.0 NNW

.0 1.0

.0

.0

.0

.0

.0 1.0 TOTAL

.0 7.0

.0

.0

.0

.0

.0 7.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-72 l'

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.1 61.0 214.0 30.0

.0

.0

.0 305.1 NNE

.1 107.0 244.0 47.0

.0

.0

.0 398.1 NE

.1 87.0 95.0

.0

.0

.0

.0 182.1 ENE

.1 59.0 21 0

.0

.0

.0

.0 80.1 E

.1 57.0 9.0

.0

.0

.0

.0 66.1 ESE

.0 43.0 3.0

.0

.0

.0

.0 46.0 i

SE

.0 40.0 1.0

.0

.0

.0

.0 41.0 SSE

.1 53.0 78.0 1.0

.0

.0

.0 132.1 S

.1 111.0 209.0 38.0

.0

.0

.0 358.1 i

SSW

.1 74.0 69.0 9.0

.0

.0

.0 152.1 SW

.0 37.0 48.0 3.0

.0

.0

.0 88.0 WSW

.0 33.0 39.0 4.0

.0

.0

.0 76.0 W

.0 18.0 40.0 1.0

.0

.0

.0 59.0 WNW

.0 17.0 20.0 1.0

.0

.0

.0 38.0 NW

.0 16.0 13.0 3.0

.0

.0

.0 32.0 NNW

.0 30.0 41.0 3.0

.0

.0

.0 74.0 TOTAL 1.0 843.0 1144.0 140.0

.0

.0

.0 2128.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON.ZERO ENTRIES IN EACH STABILITY.

E.73

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (lM)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 7.0 23.0 11.0 2.0

.0 43.0 NNE

.0

.0 1.0

'. 0 1.0

.0

.0 2.0 f

NE

.0

.0

.0

.0

.0

.0

.0

.0 i

ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 l

ESE

.0 0

.0

.0

.0

.0

.0

.0 l

i SE

.0

.0

.0

.0

.0

.0

.0

.0 f

SSE

.0

.0 23.0 28.0 2.0

.0

.0 53.0 1

S

.0

.0 10.0 5.0 4.0

.0

.0 19.0 SSW

.0

.0 1.0 5.0 4.0

.0

.0 10.0 SW

.0

.0 3.0 5.0 1.0

.0

.0 9.0 WSW

.0

.0 3.0 6.0 1.0

.0

.0 10.0 i

W

.0

.0 5.0 6.0 2.0

.0

.0 13.0 WNW

.0

.0 5.0 13.0 2.0 3.0 1.0 24.0 NW

.0

.0 4.0 5.0 16.0 5.0 1.0 31.0 NNW

.0

.0 8.0 6.0 12.0 2.0

.0 28.0 TOTAL

.0

.0 70.0 102.0 56.0 12.0 2.0 242.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-74

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0)

TO (1997/ 9/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 18.0 10.0 8.0

.0

.0 36.0 NNE

.0

.0 1.0

.0

.0

.0

.0 1.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

'.0

.0

.0

.0

.0 1.0 SSE

.0

.0 11.0 7.0 2.0

.0

.0 20.0 S

.0

.0 13.0 6.0 3.0

.0

.0 22.0 SSW

.0

.0 7.0 1.0 5.0

.0

.0 13.0

{

l SW

.0

.0 F.0 2.0 3.0

.0

.0 10.0 WSW

.0

.0 4.0 3.0

.0 1.0

.0 8.0 i

W

.0

.0 2.0 3.0 3.0

.0

.0 8.0 WNW

.0

.0 4.0 3.0 3.0

.0

.0 10.0 NW

.0

.0 3.0 1.0 1.0

.0

.0 5.0 NNW

.0

.0 6.0 1.0 3.0

.0

.0 10.0 TOTAL

.0

.0 75.0 37.0 31.0 1.0

.0 144.0 4

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-75

f l

l l

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTICNS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

)

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TCTAL N

.0

.0 19.0 10.0 2.0

.0

.0 31.0 l

NNE

.0

.0 7.0 3.0

.0

.0

.0 10.0 NE

.0

.0 1.0

.0

.0

.0

.0 1.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 l

E

.0 1.0

.0

.0

.0

.0

.0 1.0 1

ESE

.0

.0

.0 1.0

.0

.0

.0 1.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 4.0 10.0 4.0

.0

.0

.0 18.0 1

l l

S

.0 1.0 12.0 2.0 1.0

.0

.0 16.0 l

SSW

.0

.0 7.0 2.0

.0

.0

.0 9.0 SW

.0

.0 6.0

.0 1.0

.0

.0 7.0 WSW

.0 1.0 3.0 3.0 2.0 1.0

.0 10.0 l

W

.0 2.0 1.0 3.0 2.0 1.0

.0 9.0 WNW

.0

.0 3.0 2.0

.0

.0 1.0 6.0 l

NW

.0 1.0 5.0 5.0 1.0

.0

.0 12.0 NNW

.0

.0 13.0 3.0

.0 1.0

.0 17.0 TOTAL

.0 10.0 87.0 38.0 9.0 3.0 1.0 148.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED CROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E 76

/

INDIAN POINT (UNITS 2 & 3) - JOIITI' FREQUENCY *1ISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

10.50 -

24.00 -

l FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL l

N

.0 2.0 24.0 53.0 35.0 6.0

.0 120.0 NNE

.0 4.0 35.0 36.0 4.0

.0

.0 79.0 NE

.0 11.0 28.0 15.0

.0

.0

.0 54.0 ENE

.0 8.0 13.0 3.0

.0

.0

.0 24.0 E

.0 7.0 14.0 8.0 1.0

.0

.0 30.0 ESE

.0 3.0 15.0 9.0 1.0

.0

.0 28.0 SE

.0 3.0 4.0 5.0 4.0

.0

.0 16.0 SSE

.0 12.0 12.0 36.0 10.0

.0

.0 70.0 i

S

.0 17.0 20.0 35.0 8.0

.0

.0 80.0 SSW

.0 5.0 15.0 9.0 3.0

.0

.0 32.0 SW

.0 4.0 7.0 6.0 9.0

.0

.0 26.0 WSW

.0 2.0 1.0 7.0 4.0 1.0

.0 15.0 W

.0 1.0 9.0 14.0 4.0 2.0

.0 30.0 WNW

.0 2.0 6.0 8.0 3.0 2.0

.0 21.0 NW

.0 1.0 3.0 12.0 12.0 7.0 3.0 38.0 NNW

.0 2.0 9.0 24.0 32.0 7.0

.0 74.0 TOTAL

.0 84.0 215.0 280.0 130.0 25.0 3.0 737.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-77

1 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

[1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 10.0 21.0 5.0 1.0

.0

.0 37.0 NNE

.0 20.0 131.0 45.0

.0

.0

.0 196.0 NE

.0 10.0 11.0 3.0

.0

.0

.0 24.0 ENE

.0 2.0 4.0

.0

.0

.0

.0 6.0 E

.0 4.0 1.0 2.0

.0

.0

.0 7.0 ESE

.0 2.0 3.0 3.0 1.0

.0

.0 9.0 SE

.0 7.0 6.0 2.0

.0

.0

.0 15.0 SSE

.0 3.0 19.0 15.0

.0

.0

.0 37.0 S

.0 5.0 23.0 32.0 6.0

.0

.0 66.0 SSW

.0 6.0 38.0 27.0 5.0

.0

.0 76.0 SW

.0 9.0 19.0 20.0 1.0

.0

.0 49.0 WSW

.0 9.0 9.0 11.0 1.0 1.0

.0 31.0 W

.0 6.0 12.0 13.0 5.0 1.0

.0 37.0 WNW

.0 2.0 6.0 3.0 3.0

.0

.0 14.0 NW

.0 6.0 7.0 13.0 1.0 2.0

.0 29.0 NNW

.0 7.0 5.0 9.0 1.0

.0

.0 22.0 TOTAL

.0 108.0 315.0 203.0 25.0 4.0

.0 655.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E 78

1 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

l 1

I PASQUILL STABILITY:

F l

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 10.0 15.0 6.0

.0

.0

.0 31.0 NNE 0

8.0 34.0 7.0

.0

.0

.0 49.0 NE

.0 10.0 3.0

.0

.0

.0

.0 13.0 ENE

.0 1.0 1.0

.0

.0

.0

.0 2.0 E

.0 2.0

.0

.0

.0

.0

.0 2.0 ESE

.0 2.0 1.0

.0

.0

.0

.0 3.0

)

SE

.0 2.0 2.0

.0

.0

.0

.0 3.0

.0

.0

.0

.0 3.0 SSE

.0 3.0 s

S

.0 5.0 7.0 2.0

.0

.0

.0 14.0 SSW

.0 6.0 22.0 4.0

.0

.0

.0 32.0 SW

.0 1.0 6.0 1.0

.0

.0

.0 8.0 WSW

.0 4.0

.0

.0

.0

.0

.0 4.0 W

.0 2.0 3.0 2.0

.0

.0

.0 7.0 WNW

.0 2.0 4.0

.0

.0

.0

.0 6.0 NW

.0 5.0 3.0

.0

.0

.0

.0 8.0 NNW

.0 8.0 2.0

.0

.0

.0

.0 10.0 TOTAL

.0 71.0 102.0 22.0

.0

.0

.0 195.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-79

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day /Hourl

[1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0

.0

.0

.0

.0

.0 NNE

.0 2.0

.0

.0

.0

.0

.0 2.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 1.0

.0

.0

,0

.0

.0 1.0 S

.0 1.0

.0

.0

.0

.0

.0 1.0 j

SSW

.0 1.0

.0

.0

.0

.0

.0 1.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0 1.0

.0

.0

.0

.0

.0 1.0 NW

.0

.0

.0

.0

.0

.0

.0

.0 NNW

.0 1.0

.0

.0

.0

.0

.0 1.0 TOTAL

.0 7.0

.0

.0

.0

.0

.0 7.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-80

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS. JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 22.0 104.0 107.0 57.0 8.0

.0 298.0 NNE

.0 34.0 209.0 91.0 5.0

.0

.0 339.0 NE

.0 31.0 43.0 18.0

.0

.0

.0 92.0 ENE

.0 11.0 18.0 3.0

.0

.0

.0 32.0 E

.0 14.0 15.0 10.0 1.0

.0

.0 40.0 ESE

.0 7.0 19.0 13.0 2.0

.0

.0 41.0 SE

.0 12.0 12.0 7.0 4.0

.0

.0 35.0 SSE

.0 23.0 75.0 90.0 14.0

.0

.0 202.0 S

.0 29.0 85.0 82.0 22.0

.0

.0 218.0 SSW

.0 18.0 90.0 48.0 17.0

.0

.0 173.0 SW

.0 14.0 46.0 34.0 15.0

.0

.0 109.0 WSW

.0 16.0 20.0 30.0 8.0 4.0

.0 78.0 W

.0 11.0 32.0 41.0 16.0 4.0

.0 104.0 l

kRN

.0 7.0 28.0 29.0 11.0 5.0 2.0 82.0 f

NW

.0 13.0 25.0 36.0 31.0 14.0 4.0 123.0 NNW

.0 18.0 43.0 43.0 48.0 10.0

.0 162.0 TOTAL

.0 280.0 864.0 682.0 251.0 45.0 6.0 2128.0 f

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

1 E-81

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBlTTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7,50 -

12.50.

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0

.0 1.0

.0

.0 1.0 i

NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 1

E

.0

,0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0 3.0 5.0

.0

.0 8.0 J

l S

.0

.0

.0 1.0

.0

.0

.0 1.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 i

WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0 2.0 1.0

.0

.0 3.0 j

WNW

.0

.0

.0 5.0

.0 2.0

.0 7.0 NW

.0

.0

.0

.0

.0 3.0 1.0 4.0 NNW

.0

.0

.0

.0 4.0

.0

.0 4.0 l

TOTAL

.0

.0

.0 11.0 11.0 5.0 1.0 28.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 i

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-82

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS'AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0 11.0 9.0

.0

.0 20.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0 0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 6.0 6.0 1.0

.0 0

13.0 S

.0

.0

.0

.0 2.0

.0

.0 2.0 j

SSW 0

.0

.0

.0 2.0

.0

.0 2.0 j

SW

.0

.0

.0 3.0 1.0

.0

.0 4.0 WSW

.0

.0 1.0 3.0

.0

.0

.0 4.0 i

W

.0

.0 1.0 3.0

.0

.0

.0 4.0 WNW

.0

.0

.0 6.0 1.0 1.0

.0 8.0 j

NW

.0

.0 1.0 4.0 5.0

.0

.0 10.0 l

NNW

.0

.0 1.0

.0 6.0 4.0 1.0 12.0 TOTAL

.0

.0 10.0 36.0 27.0 5.0 1.0 79.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 i

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-83

i INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 I

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

IOh PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO

[1997/ 9/30/23]

j PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 15.0 20.0 9.0 4.0

.0 48.0 NNE

.0

.0 2.0 4.0 2.0

,0

.0 8.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 I

E

.0

.0 1.0

.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0 1.0

.0

.0

.0

.0 1.0 j

SSE

.0

.0 8.0 6.0 4.0

.0

.0 18.0 S

.0

.0 16.0 5.0 1.0

.0

.0 22.0 SSW

.0

.0 5.0 3.0 5.0

.0

.0 13.0 SW

.0

.0 3.0 3.0 1.0

.0

.0 7.0 WSW

.0

.0 2.0 4.0 3.0

.0

.0 9.0 W

.0

.0 1.0 6.0 1.0

.0

.0 8.0 WNW

.0

.0 4.0 6.0 1.0 1.0

.0 12.0 NW

.0

.0 3.0 4.0 4.0 2.0 1.0 14.0 NNW

.0

.0 9.0 6.0 3.0 4.0

.0 22.0 TOTAL

.0

.0 70.0 67.0 34.0 11.0 1.0 183.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-84

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BACIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/ 7/ 1/ 0]

TO (1997/ 9/30/23]

PASQUILL STABILITY:

D l

l l

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 5.0 45.0 51.0 77.0 7.0 3.0 188.0

.0

.0 86.0 NNE

.0 1.0 26.0 38.0 21.0 NE

.0 8.0 14.0 14.0 2.0

.0

.0 38.0 ENE

.0 12.0 8.0 10.0 1.0

.0

.0 31.0 E

.0 10.0 8.0 13.0 4.0 1.0

.0 36.0 ESE

.0 6.0 10.0 16.0 7.0

.0

.0 39.0 SE

.0 5.0 4.0 8.0

.0

.0

.0 17.0 I

SSE

.0 14.0 21.0 33.0 42.0

.0

.0 110.0 j

l S

.0 16.0 50.0 36.0 33.0 2.0

.0 137.0 l

SSW

.0 5.0 31.0 26.0 12.0

.0

.0 74.0 SW

.0 6.0 15.0 12.0 16.0 2.0

.0 51.0 i

l WSW

.0 1.0 6.0 15.0 9.0 4.0

.0 35.0 l

W

.0 1.0 10.0 21.0 9.0 7.0 2.0 50.0 l

l

~

WNW

.0 1.0 11.0 14.0 10.0 2.0 2.0 40.0 f

NW

.0 4.0 9.0 13.0 18.0 11.0 5.0 60.0 j

NNW

.0 1.0 21.0 26.0 26.0 11.0 2.0 87.0 1

l i

TOTAL

.0 96.0 289.0 346.0 287.0 47.0 14.0 1079.0 j

f t

l DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 j

TEMPERATURE SENSOR SEPARATION (METERS) 112.00 l

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 l

i VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 I

I 1

l l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

i E-85

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

[1997/ 7/ 1/ 0]

TO

[1997/ 9/30/23]

PASQUILL STABILITY:

E l

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL 1

N

.0 7.0 28.0 20.0 1.0 1.0

.0 57.0 NNE

.0 4.0 13.0 13.0,

.0

.0

.0 30.0 NE

.0 7.0 11.0 6.0

.0

.0

.0 24.0 ENE

.0 4.0 7.0

.0 1.0

.0

.0 12.0 E

.0 10.0 2.0 2.0

.0

.0

.0 14.0 ESE

.0 4.0 6.0

.0 1.0 1.0

.0 12.0 SE

.0 5.0 2.0 2.0 1.0

.0

.0 10.0 SSE

.0 6.0 14.0 11.0 1.0

.0

.0 32.0 S

.0 13.0 27.0 26.0 4.0

.0

.0 70 0 SSW

.0 13.0 29.0 37.0 10.0

.0

.0 89.0 SW

.0 22.0 26.0 23.0 6.0 2.0

.0 79.0 WSW

.0 9.0 20.0 11.0 5.0

.0

.0 45.0 W

.0 5.0 9.0 9.0 5.0 3.0 1.0 32.0 WNW

.0 10.0 8.0 11.0 4.0

.0

.0 33.0 NW

.0 3.0 16.0 8.0 7.0

.0 1.0 35.0 NNW

.0 8.0 12.0 9.0 2.0

.0

.0 31.0 TOTAL

.0 130.0 230.0 188.0 48.0 7.0 2.0 605.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD LALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-86

INDIAN POINT (UNITS 2 & 3)

JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 l

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

[1997/ 7/ 1/ 0]

TO

[1997/ 9/30/23]

l l

PASQUILL STABILITY:

F l

l WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL

\\

N

.0 9.0 12.0

.0

.0

.0

.0 21.0 NNE

.0 2.0 S.O 1.0

.0

.0

.Q 8.0 NE

.0

.0 3.0

.0

.0

.0

.0 3.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 j

E

.0 2.0

.0

.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0 2.0

.0

.0

.0

.0

.0 2.0 SSE

.0 1.0 1.0

.0

.0

.0

.0 2.0 S

.0 3.0 1.0

.0

.0

.0

.0 4.0 SSW

.0 6.0 11.0 2.0

.0

.0

.0 19.0 SW

.0 7.0 5.0

.0

.0

.0

.0 12.0 WSW

.0 7.0

.0 1.0

.0

.0

.0 8.0 W

.0 3.0 5.0

.0 1.0

.0

.0 9.0 K'NW

.0 6.0 5.0 1.0 1.0

.0

.0 13.0 NW

.0 9.0 10.0 1.0 1.0

.0

.0 21.0 NNW

.0 5.0 17.0 3.0 1.0

.0

.0 26.0 TOTAL

.0 63.0 75.0 9.0 4.0

.0

.0 151.0 l

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 l

l VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 l

l NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO j

ENTRIES IN EACH STABILITY.

1 i

E 8'7 l

t i

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

[1997/ 7/ 1/ 0]

TO

[1997/ 9/30/23]

l i

PASQUILL STABILITY:

G i

I i

WIND SPEED (MPH) i WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

1 FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL i

N

.0

.0

.0

.0

.0

.0

.0

.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0

.0

.0

.O

.0

.0 l

S

.0

.0

.0

.0

.0

.0

.0

.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0 1.0

.0

.0

.0

.0

.0 1.0 WNW

.0 1.0

.0

.0

.0

.0

.0 1.0 NW

.0

.0

.0

.0

.0

.0

.0

.0 j

NNW

.0 1.0

.0

.0

.0

.0

.0 1.0

{

TOTAL

.0 3.0

.0

.0

.0

.0

.0 3.0 l

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OSS. DURING THIS PERIOD (ALL STABILITIES) 80 VALIO OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-88

I l

I l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - JUL/AUG/SEP 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

[1997/ 7/ 1/ 0}

TO

[1997/ 9/30/23]

J l

I PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.53 18.50 24.00 80.00 TOTAL N

.0 21.0 100.0 102.0 97.0 12.0 3.0 335.0 I

i NNE

.0 7.0 46,0 56.0 23.0

.0

.0 132.0 NE

.0 15.0 28.0 20.0 2.0

.0

.0 65.0 ENE

.0 17.0 15.0 10.0 2.0

.0

.0 44.0 E

.0 22.0 11.0 15.0 4.0 1.0

.0 53.0 ESE

.0 10.0 16.0 16.0 8.0 1.0

.0 51.0 SE

.0 12.0 7.0 10.0 1.0

.0

.0 30.0 SSE

.0 21.0 50.0 59.0 53.0

.0

.0 183.0 S

.0 32.0 94.0 68.0 40.0 2.0

.0 236.0 SSW

.0 24.0 76.0 68.0 29.0

.0

.0 197.0 SW

.0 35.0 49.0 41.0 24.0 4.0

.0 153.0 WSW

.0 17.0 29.0 34.0 17.0 4.0

.0 101.0 W

.0 10.0 26.0 41.0 17.0 10.0 3.0 107.0 WNW

.0 18.0 28.0 43.0 17.0 6.0 2.0 114.0 NW

.0 16.0 39.0 30.0 35.0 16.0 8.0 144.0 NNW

.0 15.0 60.0 44,0 42.0 19.0 3.0 183.0 TOTAL

.0 292.0 674.0 657.0 411.0 75.0 19.0 2128.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 80 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2128 l

l l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

[

l E-89

1 l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

A WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 11.0

.0

.0

.0

.0 11.0 NNE

.S

.0 1.0

.0

.0

.0

.0 1.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 FE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 6.0

.0

.0

.0

.0 6.0 S

.0

.0 1.0

.0

.0

.0

.0 1.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0 3.0

.0

.0

.0

.0 3.0 W

.0

.0 2.0

.0

.0

.0

.0 2.0 WNW

.0

.0 7.0 1.0

.0

.0

.0 8.0 NW

.0

.0 10.0

.0

.0

.0 0

10.0 NNW

.0

.0 3.0

.0

.0

.0

.0 3.0 TOTAL

.0

.0 44.0 1.0

.0

.0

.0 45.0 4

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEFTRATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 I

l l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO EN'I' RIES IN EACH STABILITY.

l I

E-90

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 15'97 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (;M)

FOR PERIOD [ Year / Month / Day / Hour]

[1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.90 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50

'.50 12.50 18.50 24.00 80.00 TOTAL l

N

.0

.0 8.0 1.0

.0

.0

.0 9.0 NNE

.0

.0 3.0

1. 0.

.0

.0

.0 4.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0 1.0

.0

.0

.0

.0 1.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 3.0

.0

.0

.0

.0 3.0 S

.0

.0 5.0

.0

.0

,0

.0 5.0 SSW

.0

.0 2.0

.0

.0

.0

.0 2.0 SW

.0

.0 3.0

.0

.0

.0

.0 3.0 WSW

.0

.0 1.0

.0

.0

.0

.0 1.0 W

.0

.0 2.0

.0

.0

.0

.0 2.0 WNW

.0

.0 2.0 4.0

.0

.0

.0 6.0 l

NW

.0

.0 6.0 4.0

.0

.0

.0 10.0 l

bRGi

.0

.0 2.0

.0

.0

.0

.0 2.0 TOTAL

.0

.0 38.0 10.0

.0

.0

.0 48.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-91 l

t

INDIAN POINT (UNITS 2 & 3) - JOINT FREC'JENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO

[1997/12/31/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 16.0 2.0

.0

.0

.0 18.0 NNE

.0

.0 1.0 1.0

.0

.0

.0 2.0 NE

.0

.0

.0 3.0

.0

.0

.0 3.0 ENE

.0

.0 1.0

.0

.0

.0

.0 1.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 4.0 2.0

.0

.0

.0

.0 6.0 S

.0 2.C 6.0 1.0

.0

.0

.0 9.0 SSW

.0

.0 6.0

.0

.0

.0

.0 6.0 SW

.0

.0 2.0 1.0

.0

.0

.0 3.0 WSW

.0 1.0 3.0

.0

.0

.0

.0 4.0 W

.0 1.0 3.0

.0

.0

.0

.0 4.0 WNW

.0

.0 7.0 3.0

.0

.0

.0 10.0 NW

.0

.0 7.0 9.0 1.0

.0

.0 17.0 NNW

.0

.0 8.0 2.0 1.0

.0

.0 11.0 TOTAL

.0 8.0 62.0 22.0 2.0

.0

.0 94.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN t'.CH STABILITY.

E 92

l l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 l

BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23}

I PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

2.0 17.0 107.0 21.0

.0

.0

.0 147.0 NNE 2.8 24.0 124.0 116.0 2.0

.0

.0 268.8 NE 3.7 32.0 30.0 8.0

.0

.0

.0 73.7 ENE

.3 3.0 6.0 3.0

.0

.0

.0 12.3 E

.9 8.0 5.0

.0

.0

.0

.0 13.9 ESE 1.0 9.0

.0

.0

.0

.0

.0 10.0 SE

.9 8.0

.0

.0

.0

.0

.0 8.9 SSE 2.3 20.0 13.0 2.0

.0

.0

.0 37.3 S

3.1 27.0 41.0 11,0

.0

.0

.0 82.1 SSW 1.5 13.0 19.0 4.0

.0

.0

.0 37.5 SW 1.4 12.0 6.0 1.0

.0

.0

.0 20.4 WSW 1.0 9.0 22.0

.0

.0

.0

.0 32.0 W

1.3 11.0 49.0 13.0

.0

.0

.0 74.3 WNW

.5 4.0 55.0 17.0

.0

.0

.0 76.5 NW

.6 5.0 76.0 51.0 16.0

.0

.0 148.6 NNW

.8 7.0 58.0 21.0

.0

.0

.0 86.8 l

l l

TOTAL 24.0 209.0 611.0 268.0 18.0

.0

.0 1130,0 l

l l

l l

l DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 l

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-93

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 l

BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M) i FOR PERIOD [ Year / Month / Day / Hour]

I (1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12 50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.1 21.0 14.0

.0

.0

.0

.0 35.1 NNE

.1 55.0 58.0 4.0

.0

.0

.0 117.1 NE

.1 40.0 38.0

.0

.0

.0

.0 78.1 ENE

.1 22.0 2.0

.0

.0

.0

.0 24.1 E

.1 23.0

.0

.0

.0

.0

.0 23.1 ECE

.0 11.0

.0

.0

.0

.0

.0 11.0 SE

.1 25.0 1.0

.0

.0

.0

.0 26.1 SSE

.1 52.0 13.0

.0

.0

.0

.0 65.1 S

.1 47.0 33.0 10.0

.0

.0

.0 90.1 SSW

.1 32.0 10.0 1.0

.0

.0

.0 43.1 SW

.1 23.0 4.0

.0

.0

.0

.0 27.1 WSW

.1 25.0 7.0

.0

.0

.0

.0 32.1 W

.0 9.0 9.0

.0

.0

.0

.0 18.0 WNW

.0 8.0 11.0 1.0

.0

.C

.0 20.0 NW

.0 13.0 7.0

.0

.0 0

.0 20.0 NNW

.0 9.0 7.0

.0

.0

.0

.0 16.0 TOTAL 1.0 415.0 214.0 16.0

.0

.0

.0 646.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E 94 I

i

f i

{

l i

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M) l FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

1 PASQUILL STABILITY:

F I

l WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL l

t N

.0 21.0

.0

.0

.0

.0

.0 21.0 NNE

.0 60.0 35.0

.0

.0

.0

.0 95.0 l

NE

.0 24.0 20.0

.0

.0

.0

.0 44.0 i

i ENE

.0 9.0 1.0

.0

.0

.0

.0 10.0 E

.0 3.0 1.0

.0

.0

.0

.0 4.0 ESE

.0 1.0

.0

.0

.0

.0

.0 1.0 SE

.0 3.0

.0

.0

.0

.0

.0 3.0 SSE

.0 7.0

.0

.0

.0

.0

.0 7.0 S

.0 7.0 2.0

.0

.0

.0

.0 9.0 SSW

.0 4.0

.0

.0

.0

.0

.0 4.0 SW

.0 2.0

.0

.0

.0 0

.0 2.0 WSW

.0 4.0

.0

.0

.0

.0

.0 4.0 W

.0 1.0

.0

.0

.0

.0

.0 1.0 WNW

.0 1.0

.0

.0

.0

.0

.0 1.0 NW

.0 5.0

.0

.0

.0

.0

.0 5.0 NNW

.0 5.0

.0

.0

.0

.0

.0 5.0 TOTAL

.0 157.0 59.0

.0

.0

.0

.0 216.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 l

TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY, 1

l 1

l l

E-95 l

INDIAN POINT (UNITS 2 & 3) - JOINi FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD (Year / Month / Day / Hour)

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 7.0

.0

.0

.0

.0

.0 7.0 NNE

.0 7.0 2.0

.0

.0

.0

.0 9.0 NE

.0 1.0 1.0

.0

.0

.0

.0 2.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 E

.0 1.0

.0

.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0 1.0

.0

.0

.0

.0

.0 1.0 SSE

.0 1.0

.0

.0

.0

.0

.0 1.0 S

.0 1.0

.0

.0

.0

.0

.0 1.0 SSW

.0 1.0

.0

.0

.0

.0

.0 1.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.r 6

.0

.0

.0

.0

.0

.0 WNW

.D 1.0

.0

.0

.0

.0

.0 1.0 NW

.0 1.0

.0

.0

.0

.0

.0 1.0 NNW

.0 1.0

.0

.0

.0

.0

.0 1.0 TOTAL

.0 24.0 3.0

.0

.0

.0

.0 27.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l l

l E-96 1

i INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 10.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

I'597/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

]

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

2.0 66.0 156.0 24.0

.0

.0

.0 248.0 NNE 2.9 146.0 224.0 122.0 2.0

.0

.0 496.9 NE 3.8 97.0 89.0 11.0

.0

.0 0

200.8 ENE

.4 35.0 11.0 3.0

.0

.0

.0 49.4 E

1.0 35.0 6.0

.0

.0

.0

.0 42.0 ESE 1.1 21.0

.0

.0

.0

.0

.0 22.1 SE 1.0 37.0 1.0

.0

.0

.0

.0 39.0 S2E 2.4 84.0 37.0 2.0

.0

.0

.0 125.4 S

3.2 84.0 88.0 22.0

.0

.0

.0 197.2 SSW 1.6 50.0 37.0 5.0

.0

.0

.0 93.6 SW 1.4 37.0 15.0 2.0

.0

.0

.0 55.4 WSW 1.1 39.0 36.0

.0

.0

.0

.0 76.1 W

1.3 22.0 65.0 13.0

.0

.0

.0 101.3 WNW

.5 14.0 82.0 26.0

.0

.0

.0 122.5 NW

.6 24.0 106.0 64.0 17.0

.0

.0 211.6 bR54

.8 22.0 78.0 23.0 1.0

.0

.0 124.8 TOTAL 25.0 813.0 1031.0 317.0 20.0

.0

.0 2206.0 l

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 10.00 l

TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 l

l VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 l

l l

l NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-97

(

]

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour) i (1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

A i

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 1.0 7.0 2.0

.0

.0 10.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 l

ENE

.0

.0

.0

.0

.0

.0

.0

.0 l

l E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 1.0 6.0

.0

.0

.0 7.0 S

.0

.0

.0

.0

.0

.0

.0

.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 l

SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0 1.0

.0

.0

.0 1.0 W

.0

.0 1.0 1.0

.0

.0

.0 2.0 WNW

.0

.0

.0 5.0 3.0 1.0

.0 9.0 NW

.0

.0

.0 3.0 10.0 1.0

.0 14.0 l

NNW

.0

.0

.0 1.0 1.0

.0

.0 2.0 TOTAL

.0

.0 3.0 24.0 16.0 2.0

.0 45.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 i

MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 l

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l E-98 l

l

INDIAN POINT (UNITS 2 & 3). JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 4.0 2.0 2.0

.0

.0 8.0 NNE

.0

.0 1.0 1.0

.0

.0

.0 2.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0 1.0

.0

.0

.0 1.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 3.0 4.0

.0

.0

.0 7.0 S

.0

.0 1.0

.0

.0

.0

.0 1.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0 2.0

.0

.0

.0 2.0 WSW

.0

.0 2.0 1.0

.0

.0

.0 3.0 W

.0

.0 1.0 2.0

.0

.0

.0 3.0 WNW

.0

.0

.0 1.0 3.0 3.0

.0 7.0 NW

.0

.0

.0 2.0 5.0 3.0

.0 10.0 NNW

.0

.0 1.0 3.0

.0

.0

.0 4.0 TOTAL

.0

.0 13.0 19.0 10.0 6.0

.0 48.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-99

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 6.0 9.v 2.0

.0

.0 17.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0 3.0

.0

.0 3.0 ENE

.0

.0

.0 1.0

.0

.0

.0 1.0 E

.0

.0

.0 1.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0 1.0

.0

.0

.0

.0 1.0 SSE

.0

.0 8.0 1.0

.0

.0

.0 9.0 S

.0

.0 6.0 1.0 1.0

.0

.0 8.0 SSW

.0

.0

.0 1.0

.0

.0

.0 1.0 SW

.0

.0 2.0

.0

.0

.0

.0 2.0 WSW

.0 1.0 2.0 2.0 3.0

.0

.0 8.0 W

.0

.0 1.0

.0

.0

.0

.0 1.0 WNW

.0

.0 1.0 4.0 4.0 2.0

.0 11.0 NW

.0 1.0 1.0 4.0 7.0 3.0 4.0 20.0 NNW

.0

.0 3.0 2.0 4.0 1.0 1.0 11.0 TOTAL

.0 2.0 31.0 26.0 24.0 6.0 5.0 94.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-100

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 9.0 55.0 93.0 83.0 12.0

.0 252.0 NNE

.0 10.0 58.0 53.0 25.0 1.0

.0 147.0 NE

.0 6.0 34.0 15.0 9.0

.0

.0 64.0 ENE

.0 5.0 5.0 5.0 1.0

.0

.0 16.0 E

.0 2.0 5.0 4.0 2.0 2.0

.0 15.0 ESE

.0 5.0 1.0 1.0 1.0

.0

.0 8.0

)

SE

.0 9.0 3.0

.0

.0

.0

.0 12.0 SSE

.0 12.0

.8.0 13.0

.0

.0

.0 43.0 S

.0 15.0 23.0 18.0 4.0

.0

.0 60.0 SSW

.0 13.C 14.0 6.0 6.0

.0

.0 39.0 SW

.0 5.0 8.0 8.0 3.0

.0

.0 24.0 WSW

.0 5.0 6.0 10.0 5.0

.0

.0 26.0 W

.0 6.0 12.0 28.0 19.0 3.0

.0 68.0 WNW

.0 4.0 7.0 30.0 41.0 5.0

.0 87.0 NW

.0 4.0 6.0 41.0 83.0 28.0 26.0 188.0 NNW

.0 5.0 8.0 29.0 22.0 15.0 2.0 81.0 TOTAL

.0 115.0 263.0 354.0 304.0 66.0 28.0 1130.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

l 1

1 E.101 l

l

I 1

I INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 1

i BASIC METEOROLOGICAL OBSERVATICNS AT 60.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0)

TO (1997/12/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 6.0 19.0 9.0 1.0

.0

.0 35.0 NNE

.0 19.0 90.0 29.0 2.0

.0

.0 140.0 NE

.0 13.0 14.0 3.0 2.0

.0

.0 32.0 ENE

.0 6.0 9.0

.0

.0

.0

.0 15.0 E

.0 11.0 4.0

.0

.0

.0

.0 15.0 ESE

.0 6.0 6.0

.0

.0

.0

.0 12.0 SE

.0 3.0 8.0 1.0

.0

.0

.0 12.0 SSE

.0 10.0 19.0 13.0

.0

.0

.0 42,0 i

S

.0 9.0 28.0 16.0 3.0

.0

.0 56.0 SSW

.0 12.0 37.0 21.0 8.0

.0

.0 78.0 SW

.0 12.0 36.0 12.0

.0

.0

.0 60.0 WSW

.0 8.0 19.0 6.0 2.0

.0

.0 35.0 W

.0 3.0 14.0 4.0 1.0

.0

.0 22.0 WNW

.0 2.0 16.0 11.0 6.0

.0

.0 35.0 NW

.0 1.0 10.0 10.0 8.0

.0

.0 29.0 NNW

.0 9.0 11.0 6.0 2.0

.0

.0 28.0 TOTAL

.0 130.0 340.0 141.0 35.0

.0

.0 646.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E 102

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 i

BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M) l FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

F l

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL

\\

l N

.0 15.0 12.0 2.0

.0

.0

.0 29.0 NNE

.0 12.0 40.0 15.0

.0

.0

.0 67.0 i

NE

.0 6,0 6.0

.0

.0

.0

.0 12.0 ENE

.0 6.0 3.0

.0

.0

.0

.0 9.0 E

.0 3.0 1.0

.0

.0

.0

.0 4.0 ESE

.0 2.0

.0

.0

.0

.0

.0 2.0 SE

.0 3.0

.0

.0

.0

.0

.0 3.0 SSE

.0 6.0 2.0 1.0

.0

.0

.0 9.0 S

.0 8.0 3.0 1.0

.0

.0

.0 12.0 SSW

.0 11.0 5.0 2.0

.0

.0

.0 18.0 SW

.0 6.0 7.0 4.0

.0

.0

.0 17.0 WSW

.0 6.0 2.0 1.0

.0

.0

.0 9.0 W

.0 8.0

.0

.0

.0

.0

.0 8.0 WNW

.0 4.0

.0

.0

.0

.0

.0 4.0 NW

.0 5.0

.0

.0

.0

.0

.0 5.0 NNW

.0 5.0 2.0 1.0

.0

.0

.0 8.0 TOTAL

.0 106.0 83.0 27.0

.0

.0

.0 216.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILIT'ES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206

)

l l

l NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY I

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO l

ENTRIES IN EACH STABILITY.

E-103

i l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

G WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 3.0 1.0 1.0

.0

.0

.0 5.0 NNE

.0 4.0

.0 1.0

.0

.0

.0 5.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0 1.0

.0

.0

.0

.0

.0 1.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0 3.0

.0

.0

.0

.0

.0 3.0 I

S

.0

.0 1.0

.0

.0

.0

.0 1.0 SSW

.0 2.0 2.0

.0

.0

.0

.0 4.0 SW

.0 1.0 1.0

.0

.0

.0

.0 2.0 WSW

.0 2.0 2.0

.0

.0

.0

.0 4.0 W

.0 1.0 1.0

.0

.0

.0

.0 2.0 WNW

.0

.0

.0

.0

.0

.0

.0.

.0 l

NW

.0

.0

.0

.0

.0

.0

.0

.0 ban

.0

.0

.0

.0

.0

.0

.0

.0 j

TOTAL

.0 17.0 8.0 2.0

.0

.0

.0 27.0 l

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 l

l l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY l

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E 104 l

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 60.0

(; )

M FOR PERIOD (Year / Month / Day / Hour)

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY: ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 33.0 98.0 123.0 90.0 12.0

.0 356.0 NNE

.0 45.0 189.0.

99.0 27.0 1.0

.0 361.0 NE

.0 25.0 54.0 18.0 14.0

.0

.0 111.0 ENE

.0 17.0 17.0 7.0 1.0

.0

.0 42.0 E

.0 17.0 10.0 5.0 2.0 2.0

.0 36.0 ESE

.0 13.0 7.0 1.0 1.0

.0

.0 22.0 SE

.0 15.0 12.0 1.0

.0

.0

.0 28.0 SSE

.0 31.0 51.0 38.0

.0

.0

.0 120.0 S

.0 32.0 62.0 36.0 8.0

.0

.0 138.0 SSW

.0 38.0 58.0 30.0 14.0

.0

.0 140.0 SW

.0 24.0 54.0 26.0 3.0

.0

.0 107.0 WSW

.0 22.0 33.0 21.0 10.0

.0

.0 86.0 W

.0 18.0 30.0 35.0 20.0 3.0

.0 106.0 WNW

.0 10.0 24.0 51.0 57.0 11.0

.0 153.0 NW

.0 11.0 17.0 60.0 113.0 35.0 30.0 266.0 NNW

.0 19.0 25.0 42.0 29.0 16.0 3.0 134.0 TOTAL

.0 370.0 741.0 593.0 389.0 80.0 33.0 2206.0 i

DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 60.00 TEMPERATURE SENSOR SEPARATION (METERS) 50.90 l

l MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO i

ENTRIES IN EACH STABILITY.

E 105 1

[

j INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 l

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1597/12/31/23]

I l

PASQUILL STABILITY:

A

)

WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0

.0

.0

.0

.0

.0 NNE

.0

.0

.0

.0

.0

.0

.0

.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 l

ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 2

SE

.0

.0

.0

.0

.0

.0

.0

.0 i

SSE

.0

.0

.0

.0

.0

.0

.0

.0 S

.0

.0

.0

.0

.0

.0

.0

.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0

.0

.0

.0 1.0

.0

.0 1.0 NNW

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0

.0

.0

.0 1.0

.0

.0 1.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 l

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY l

OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

1 E-106

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

B WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0

.0 2.0 1.0

.0

.0 3.0 NNE

.0

.0

.0 1.0

.0

.0

.0 1.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 i

)

SSE

.0

.0

.0 4.0

.0

.0

.0 4.0 S

.0

.0 1.0

.0

.0

.0

.0 1.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW

.0

.0

.0 1.0

.0

.0

.0 1.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0

.0

.0 3.0

.0 1.0

.0 4.0 NW

.0

.0

.0

.0 1.0 1.0

.0 2.0 NNW

.0

.0

.0

.0

.0

.0

.0

.0 TOTAL

.0

.0 1.0 11.0 2.0 2.0

.0 16.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 i

NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-107

l INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 1

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0

(. )

M FOR PERIOD [ Year / Month / Day / Hour)

[1997/10/ 1/ 0]

TO

[1997/12/31/23}

PASQUILL STABILITY:

C WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL l

l N

.0

.0 1.0 4.0 5.0

.0

.0 10.0

.0

.0

.0

.0

.0

.0

.0

.0 NNE NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0

.0

.0

.0

.0

.0

.0

.0 i

E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE

.0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0 1.0 2.0

.0

.0

.0 3.0 S

.0

.0 2.0

.0

.0

.0

.0 2.0 SSW

.0

.0

.0

.0

.0

.0

.0

.0 SW

.0

.0

.0

.0 1.0

.0

.0 1.0 WSW

.0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0 1.0 1.0 1.0

.0

.0 3.0 WNW

.0

.0 2.0 2.0 6.0

.0 2.0 12.0 NW

.0

.0

.0 2.0 5.0 3.0

.0 10.0 NNW

.0

.0

.0

.0

.0 2.0

.0 2.0 TOTAL

.0

.0 7.0 11.0 18.0 5.0 2.0 43.0 DATA MEASUREMENT HEIGHT (M AEOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-108

1 INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

D WIND SPEED (MPH) j l

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 8.0 38.0 99.0 93.0 52.0 7.0 297.0 NNE

.0 6.0 41.0 50.0 17.0 15.0 1.0 130.0 NE

.0 6.0 23.0 14.0 13.0 9.0

.0 65.0 ENE

.0 4.0 10.0 9.0 3.0

.0

.0 26.0 E

.0 3.0 11.0 1.0 3.0 2.0 3.0 23.0 ESE

.0 4.0

.0

.0 3.0

.0

.0 7.0 SE

.0 12.0 5.0 2.0

.0

.0

.0 19.0 SSE

.0 11.0 24.0 18.0 9.0

.0

.0 62.0 S

.0 7.0 31.0 19.0 10.0 1.0

.0 68.0 SSW

.0 6.0 17.0 7.0 17.0 3.0

.0 50.0 SW

.0 5.0 9.0 12.0 5.0 2.0

.0 33.0 WSW

.0 9.0 7.0 11.0 17.0

.0

.0 44.0 W

.0 6.0 9.0 30.0 31.0 11.0 2.0 89.0 WNW

.0 5.0 8.0 43.0 56.0 19.0 7.0 138.0 NW

.0 1.0 8.0 42.0 83.0 52.0 52.0 238.0 NNW

.0 9.0 10.0 14.0 33.0 12.0 9.0 87.0 TOTAL

.0 102.0 251.0 371.0 393.0 178.0 81.0 1376.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E.109

l J

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M) l FOR PERIOD [ Year / Month / Day /Hourl (1997/10/ 1/ 0]

TO

[1997/12/31/23]

PASQUILL STABILITY:

E WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 12.0 22.0 24.0 7.0

.0

.0 65.0 NNE

.0 10.0 15.0 9.0 1.0

.0

.0 35.0 i

NE

.0 14.0 14.0 4.0 1.0

.0

.0 33.0 ENE

.0 11.0 5.0 2.0

.0

.0

.0 18.0 E

.0 9.0 12.0 3.0

.0

.0

.0 24.0 ESE

.0 12.0 4.0 3.0

.0

.0

.0 19.0 SE

.0 3.0 4.0 4.0

.0

.0

.0 11.0 SSE

.0 8.0 10.0 10.0 3.0

.0

.0 31.0 S

.0 9.0 49.0 18.0 4.0

.0

.0 80.0 SSW

.0 10.0 25.0 25.0 9.0 2.0

.0 71.0 SW

.0 13.0 21.0 28.0 2.0

.0

.0 64.0 WSW

.0 6.0 28.0 11.0 4.0

.0

.0 49.0 W

.0 3.0 7.0 5.0 1.0 1.0

.0 17.0 WNW

.0 5.0 12.0 7.0 7.0

.0

.0 31.0 NW

.0 9.0 8.0 5.0 2.0

.0

.0 24.0 NNW

.0 11.0 11.0 9.0 4.0

.0

.0 35.0 TOTAL

.0 145.0 247.0 167.0 45.0 3.0

.0 607.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-110

i INDIAN POINT (UF ITS 2 & 3)

JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

FOR PERIOD [ Year / Month / Day / Hour)

(1997/10/ 1/ 0}

TO (1997/12/31/23]

PASQUILL STABILITY:

F l

l WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 2.0 6.0 0.0

.0

.0

.0 16.0 NNE

.0 2.0 8.0 5.0

.0

.0

.0 15.0 NE

.0 5.0 3.0 1.0

.0

.0

.0 9.0 ENE

.0 3.0 3.0

.0

.0

.0

.0 6.0 E

.0 1.0 1.0

.0

.0

.0

.0 2.0 ESE

.0 3.0

.0

.0

.0

.0

.0 3.0 SE

.0 4.0

.0

.0

.0

.0

.0 4.0 i

SSE

.0 10.0 5.0

.0

.0

.0

.0 15.0 S

.0 15.0 9.0

.0

.0

.0

.0 24.0 SSW

.0 8.0 15.0 1.0

.0

.0

.0 24.0 SW

.0 5.0 6.0 2.0

.0

.0

.0 13.0 WSW

.0

.0 4.0 1.0

.0

.0

.0 5.0 W

.0 3.0

.0 2.0 1.0

.0

.0 6.0 WNW

.0 2.0

.0

.0

.0

.0

.0 2.0 NW

.0 1.0 2.0

.0

.0

.0

.0 3.0 NNW

.0 3.0 4.0 2.0

.0

.0

.0 9.0 TOTAL

.0 67.0 66.0 22.0 1.0

.0

.0 156.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 l

VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY.

E-111

1 1

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 l

l l

BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (M)

I FOR PERIOD [ Year / Month / Day / Hour]

l (1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

G i

I WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0

.0 1.0

.0

.0

.0

.0 1.0 NNE

.0 1.0

.0

.0

.0

.0

.0 1.0 NE

.0

.0

.0

.0

.0

.0

.0

.0 ENE

.0 1.0

.0

.0

.0

.0

.0 1.0 E

.0

.0

.0

.0

.0

.0

.0

.0 ESE

.0

.0

.0

.0

.0

.0

.0

.0 SE 0

.0

.0

.0

.0

.0

.0

.0 SSE

.0

.0

.0

.0

.0

.0

.0

.0 S

,0

.0

.0

.0

.0

.0

.0

.0 SSW

.0

.0 2.0

.0

.0

.0

.0 2.0 SW

.0

.0

.0

.0

.0

.0

.0

.0 WSW 0

.0

.0

.0

.0

.0

.0

.0 W

.0

.0

.0

.0

.0

.0

.0

.0 WNW

.0

.0

.0

.0

.0

.0

.0

.0 NW

.0

.0

.0

.0

.0

.0

.0

.0 NNW

.0

.0 2.0

.0

.0

.0

.0 2.0 TOTAL

.0 2.0 5.0

.0

.0

.0

.0 7.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURING THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO

. ENTRIES IN EACH STABILITY.

l E-112

INDIAN POINT (UNITS 2 & 3) - JOINT FREQUENCY DISTRIBUTIONS - OCT/NOV/DEC 1997 BASIC METEOROLOGICAL OBSERVATIONS AT 122.0 (!O FOR PERIOD (Year / Month / Day / Hour]

(1997/10/ 1/ 0]

TO (1997/12/31/23]

PASQUILL STABILITY:

ALL WIND SPEED (MPH)

WIND

.60 -

3.50 -

7.50 -

12.50 -

18.50 -

24.00 -

FROM CALMS 3.50 7.50 12.50 18.50 24.00 80.00 TOTAL N

.0 22.0 68.0 137.0 106.0 52.0 7.0 392.0 NNE

.0 19.0 64.0 65.0 18.0 15.0 1.0 182.0 NE

.0 25.0 40.0 19.0 14.0 9.0

.0 107.0 ENE

.0 19.0 18.0 11.0 3.0

.0

.0 51.0 E

.0 13.0 24.0 4.0 3.0 2.0 3.0 49.0 ESE

.0 19.0 4,0 3.0 3.0

.0

.0 29.0 SE

.0 19.0 9.0 6.0

.0

.0

.0 34.0 SSE

.0 29.0 40.0 34.0 12.0

.0

.0 115.0 S

.0 31.0 92.0 37.0 14.0 1.0

.0 175.0 SSW

.0 24.0 59.0 33.0 26.0 5.0

.0 147,0 SW

.0 23.0 36.0 42.0 8.0 2.0

.0 111.0 WSW

.0 15.0 39.0 24.0 21.0

.0

.0 99.0 W

.0 12.0 17.0 38.0 34.0 12.0 2.0 115.0 WNW

.0 12,0 22.0 55.0 69.0 20.0 9.0 187.0 NW

.0 11.0 18.0 49.0 92.0 56.0 52.0 278.0 NNW

.0 23.0 27.0 25.0 37.0 14.0 9.0 135.0 TOTAL

.0 316.0 577.0 582.0 460.0 188.0 83.0 2206.0 DATA MEASUREMENT HEIGHT (M ABOVE GRADE) 122.00 TEMPERATURE SENSOR SEPARATION (METERS) 112.00 MISSING OBS. DURING THIS PERIOD (ALL STABILITIES) 2 VALID OBSER. DURI'1G THIS PERIOD (ALL STABILITIES) 2206 NOTE: CALMS WERE DISTRIBUTED IN PROPORTION TO THE FREQUENCY OF WINDS IN THE LOWEST WIND SPEED GROUP WITH NON-ZERO ENTRIES IN EACH STABILITY, E-113

ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT F - REPORTABLE CHANGES TO THE PROCESS CONTROL PROGRAM (PCP)

.OFFSITE DOSE CALCULATION MANUAL (ODCMJ AND RADIOACTIVE WASTE SYSTEMS G - REPORTABLE ITEMS THE RADIOACTIVE LIOUID EFFLUENT MONITORING INSTRUMENTATIQN RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION H - UNPLANNED RELEASES 1222 CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.

INDIAN POINT UNIT NOS.1 & 2 DOCKET NOS. 50-03 & 50-247 MAY,1998

/

SECTION F Reportable Chances A.

Process Control Procram (PCP)

Section 6.14.1 of the Indian Point Unit No. 2 Technical Specifications requires that licensee initiated changes to PCP be reported to the Commission in the Annual Radioactive Etfluent Release Report. During the 1997 reporting period there were no changes made.

B.

Offsite Dose Calculation Manual (ODCM)

Section 6.15.2 of the Indian Point Unit No. 2 Technical Specifications requires that changes to ODCM be reported to the Commission in the Annual Radioactive Effluent Release Report. During the 1997 reporting period there were no changes made.

C.

Radioactive Waste Systems (RWS)

Section 6.16.1 of the Indian Point Unit No. 2 Technical Specifications requires that major changes to RWS be reported to the Commission in the Annual Radioactive Effluent Release Report. During the 1997 reporting period there were no major changes made to the RWS.

4 F-1

i l

SECTION G Renortable Items A.

Radioactive Liould Effluent Monitorine Instrumentation I

l During the 1997 refueling outage, R-46 and R-53 Fan Cooler Units Service Water Outlet Monitors, were out-of-service for greater than 30 days contrary to the requirements of Technical Specification 3.9.A.2.c.

The monitors were out of service while maintenance activities were performed which isolated the monitors from the Service Water flow stream. During the out-of-service period for these monitors compensatory monitoring was performed by the chemistry section as required by the above Technical Specification.

During three separate 1997 outage periods, R-49, the Steam Generator Blowdown Monitor, was out of service for greater than 30 days contrary to the requirements of Technical Specification 3.9.A.2.c. The monitor was out of service since the monitor cannot pass sufficient flow to meet the monitor flow requirements with steam generators at atmospheric pressure. During releases with R-49 out-of-service compensatory monitoring was performed by the chemistry sect.bn as required by Technical Specifications.

B.

Radioactive Gaseous Effluent Monitorine Instrumentation During the period from January 1,1997 until April 16,1997, the Unit 1 Stack Vent Flow Rate Monitor was out-of-service for repair work on the monitor. The extended period was the result of the need to prepare a modification and obtain parts for the transmitter that the vendor had redesigned. The actions of Technical Specification 3.9.B.2.c requirements were complied with by performing compensatory action 4.

During the period from September 8,1997 until December 31,1997, the Unit 2 Plant Vent Flow Rate Monitor was out-of-service for repair work on the monitor. The extended time was based on delays in performing a root cause analysis for the transmitter failure and the unavailibility of replacement parts The actions of Technical Specification 3.9.B.2.c requirements were complied with by performing compensatory action 4.

During the period from January 1,1997 through July 24,1997 the Waste Gas Holdup System Explosive Monitoring System Hydrogen and Oxygen monitors reported in the 1996 Radiological Effluent Monitoring Report remained inoperable due to the monitor alarms. The modification previously reported, MOD FIX-93-56782-M and Post Modification Testing were completed on July 24,1997. Subsquently the monitor was returned to operable status and Technical Specification Table 3.9-2 Action 4 was exited. The actions of Technical Specification 3.9.B.2.c requirements were complied with by performing compensatory action 4.

G-1

a SECTION H Unolanned Releases A.

Unolanned Liauid Releass,s There were no unplanned liquid releases during the reporting period.

B.

Unolanned Gaseous Releases The following unplanned gaseous releases occurred during the reporting period:

On April 1,1997 while obtaining a Vapor Containment (VC) air sample, the sample container failed. The i

failure resulted in releasing 0.6 SCFM of atmospheric VC sample for a period of 20 minutes to the Primary

)

Auxiliary Building which resulted in an estimated release of 7.5E-6 Ci through the Plant Vent. This release i

is estimated to be less than 0.001% of Technical Specification limits.

Between August 16,1997 and August 18,1997 radiogas was released from the Refueling Water Storage Tank (RWST) when valve 4055 was closed stopping flow from the RWST to the Reactor Coolant System.

Since the RWST is vented to atmosphere the radiogas that was contained in the RWST was assumed to have been released resulting in an estimated unmonitored release of 5.05-3 Ci through the tank vent. This release is estimated to be less than 0.04% of Technical Specification limits.

3 Each of these events involved low gas voluma of high activity. The activity released from each event was properly quantified and accounted for. Appropriate corrective actions were identified and implemented.

H-1