ML20217B658

From kanterella
Jump to navigation Jump to search
Rev 28 to AR-403, PSA H Annunciator Response
ML20217B658
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 09/23/1997
From:
FLORIDA POWER CORP.
To:
Shared Package
ML20217B638 List:
References
AR-403, NUDOCS 9709300107
Download: ML20217B658 (194)


Text

'

Effective Date W g l

l INFOR V A~~ O N ON_Y >

ANNUNCIATOR RESPONSE AR-403 FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3

~

PSA H ANNUNCIATOR RESPONSE

(NV; APPROVED BY: Interpretation lCgntact t< ko fL tu)YSA/

~"~ ' '

n (51GNATURE'0

N FILE)

@l/25[Oh x_/ DATE:

INTERPRETATION CONTACT: Manager Nuclear Plant Operations support 9709300107 970924 PDR ADOCK 05000302 p PDR a

TABLE OF C04 TENTS SECTION E6Qg 1.0 PURP0ig................................................................. 1 1 Q_ REFERENCES..............................................................

2.1 IMELEMEMTING 1 REFERENCES....................... ..................... 1 2.2 DEVELOPMENTAL REFERENCES...................... ..................... 1 3 . 0 PE RSONNE L INDOCTRINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.0 1 INSTRUCTIONS............................................................ 2 12 0 FOL LOW- UP ACTI ONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ENCLOSURE 1

An n u n c i a t o r R e s po n s e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

\

\

AR-403 Rev. 28 Page i

m 1.0 PURPASI i

1.1 Establish a reference vocument for each Annunciator Window on the PSA-Z Lamp box.

1.2 Establish operator actions for valid Annunciator alarms on the PSA-Z Lamp box.

1.3 Establish a reference to other procedures which address operator actions for valid Annunciator alarms on the PSA-Z Lamp box.

LO REFERENCFJi 2.1 IMPl@ENTING REFEREEES 2.1.1 E0P, Emergency Operating Procedure 2.1.2 AP-250, Radiation Monitor Actuation 2.1.3 AP-1050, Flooding 2.1.4 CP-338, Secondary Water Chemistry Guidelines m

d 2.1.5 OP-103B, lleat-Up Cooldown Curves 2.1.6 SP-146. EFIC Monthly Functional Test 2.1.7 OP-302, RC Pump Operation 2.1.8 OP-301, Operation Of The Reactor Coolant System 2.1.9 AP-470, Loss of Instrument Air 2.1.10 OP-408, Nuclear Services Cooling System 2.1.11 OP-505, Radiation Monitoring System 2.1.12 CP-152. Primary to Secondary Leakage Operating Guideline 2.2 DEVELOPMENTAL REFERENCES 2.2.1 INPO 90-021, Good Practice OP-217, Alarm Response Procedures 2.2.2 Annunciator Window Engraving Drawing E-224-048 k

l AR-403 Rev. 28 Page 1

___ _ ._.-_ _ .-. _ ..._ _ _y _ ___.._._ . . . _ . _ . _ . _ - _ _ _ _ _ . .

i i

l  !

j 3.O PER10NNEL INDOCTRINATION j

3.1 The Annunciator System is powered from V8DP-$ Breaker 28.

i 4 4.0 INSIRUCHQNS

}

l 4.1 Respond to alarms on the PSA-Z Lamp box as indicated on Enclosure 1 Annunciator Response.

l 1 30 FOLLOW-UP ACTIONS I

j None i

1.,

a i

4 k

4

  • (

4 \

l i

1 s

I t

i i

i

,i l

a d

(

AR-403 Rev. 28 Page 2 e

?>

1

- - - - . - - - - . , - , . , _ . , , . , , .- . , , - . . - . . . . . , .. - . , , ,...,n., . - -.n -._, . . , . . , .-,--,,,,n-,..-,..,----c,,n -,,,,...-n ,- ,.,.

fRCLQiUM_.1 (Page 1 of 190)

PSA-2 ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 I

l  ; GAMMA RADIATION l l HIGH I I I I EVENT POINT 1748 INDICATED CONDITION:

o RM-C1 RADIATION LEVEL EXCEEDS HIGH SC' POINT, REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G1 INDICATION AT RADIATION MONITORING PANEL.

o RM-G1 INDICATION AT DETECTOR.

o RM-G1 RED ALARM LIGHT.

o RM-C1 HORN.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARMt o

INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-C1 MONITORS THE CONTROL ROOM. THE DETECTOR IS ON THE BACK WALL NEXT TO THE ES RELAY ACTUATION CABINETS. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-22 SENSING ELEMENT: RADIATION HONITORING PANEL AR-403 Rev. 28 Page 3

A ENCLOSRL1

() (Page 2 of 100)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H 01-01 GAMMA RADIATION HIGH EVENT POINT 1750 INDICATED CONDITION:

o RM-G2 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

(3 /

i s REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G2 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAVSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G2 MONITORS THE CHEriICAL LABORATORY THE DETECTOR IS LOCATED ON THE EAST WALL INSIDE THE CHEMICAL LABORATORY. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-23 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 4

IELO11LBE 1 (Page 3 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 l

l

! I I I I OAMMA RADIATION l HlOH I

I EVENT POINT 1752 INDICATED CONDITION:

o RM-G3 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G3 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

  • DISCUSSION:

RM-C3 MONITORS THE PRIMARY SAMPLE ROOM. THE DETECTOR IS LOCATED ON THE SOUTH WALL INSIDE THE PRIMARY SAMPLE ROOM. THE REDAS SYSTEM MAY ALSO BE

-USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-23 SENSING ELEMENT: RADIATION MONITORING PANEL.

AR-403 Rev. 28 Page 5

ENCLOSURE 1 (Page 4 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01

%ZZZZZZ l l OAMMA l l RADIATION 1 l HIGH I I I I EVENT POINT 1754 INDICATED CONDITION:

o RM-G4 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G4 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALIO ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AITA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OF-505, RADIATION MONITORING SYSTEM. '

DISCUSSION:

RM-G4 MONITORS THE AUXILIARY BUILDING ENTRANCE HALLWAY. THE DETECTOR IS LOCATED ON THE WALL OPPOSITE THE PAX PHONE NEAR THE ENTRANCE TO THE INTERMEDIATE BUILDING. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TRE INFORMATION.

REFERENCES:

DRAWING 208-049-RM-24

, SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 6

ENCLOSURt*. 1 (Page 5 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 I I l l GAMMA g l RADIATION

[

l HIGH I I I I EVENT POINT 1756 '

INDICATED CONDITION:

o RM-GS RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G5 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HICH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP 505, RADIATION MONITORING SYSTEM. '

DISCUSSION:

RM-GS MONITORS THE WASTE CAS TANK VALVE ALLEY. THE DETECTOR IS LOCATE THE 9$' AB. ON THE WALL IN THE WASTE CAS VALVE ALLEY, AD3ACENT TO T;1E DETECTOR. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFOR

REFERENCES:

DRAWING 208-049-RM-24 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 2B Page 7

, ENCLOSURE 1 (Page 6 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 l l GAMMA g  ;

RADIATION g l HIGH I I I I EVENT POINT 1758 INDICATED CONDITION:

o RM-G6 RADIATION LEVEL EXCEEDS HIGH SETPOINT. '

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G6 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o N011FY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G6 MONITORS THE MAKEUP TANK VALVE ALLEY. THE DETECTOR IS LOCATED ON THE WALL NEAR THE ENTRANCE LOCKED GATE. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-25 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 3

O ENCLOSURE _1 (Page 7 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2.01 01 H-01-01  !

WZZZZZZ l l I GAMMA l ,

RADIATION y  ;

HIGH I I I i EVENT POINT 1760 INDICATED CONDITION:

o RM-G7 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM o RM G7 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

REFER TO OP-505, RADIATION MONITORING SYSTEM.

  • DISCUSSION:

RM-G7 MONITORS THE RC BLEED TANK AREA. THE DETECTOR IS LOCATED ON THE WA NEAR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 95' ELEVATION. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-25 SENSING ELEMENT: RADIATION MONITORING PANEL AR-103 Rev. 28 Page 9

i O ENCLOSURE 1 (Page 8 of 190)

PSA-Z ANNbNCIATOR RESPONSE PSA-Z-01-01 l H-01-01 1

l I y  ;

OAMMA g l RADIATION l l HIGH I I I I EVENT POINT 1762 INDICATED CONDITION:

o RM-C8 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G8 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH PADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-C8 MONITORS THE RC BLEED TANK AREA. THE DETECTOR IS LOCATED ON TH NEAR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 119' ELEVATION. THE RE SYSTEM MAY ALSO BE USED TO 0BSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-26 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Revi 28 Page 10

ENCLOSURE 1 (Page 9 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H 01-01 I I GAMMA l l RADIATION g l HIGH I I I I EVENT POINT 1764 INDICATED CONDITION:

o RM-G9 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G9 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION. '

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

  • DISCUSSION:

1 RM-G9 MONITORS THE AREA OUTSIDE THE PERSONNEL HATCH. THE DETECTOR IS LOCATED ON THE WALL NEAR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 119' ELEVATION. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-26 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 11 I

  • ,y -

'+-y-'-

ENCLOSURE 1

} (Page 10 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 i

g  ;

GAMMA l  ; RADIATION

[ l HIGH I

I

EVENT POINT 1766 j INDICATED CONDITION:

o RM-CID RADIATION LEVEL EXCEEDS HIGH SETPOINT.

I REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

. o RM-G10 INDICATION AT RADIATION MONITORING PANEL.

i I

3 -

OPERATOR ACTIONS FOR A VALID ALARM:

i o INVEiTIGATE CAUSE OF HIGH RADIATION.

4 o NOT' FY HEALTH PHYSICS TO MONITOR AFFECT 5.D AkEA(S).

o OB56RVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-CIO MONITORS THE MAKE-UP PUMP AREA. THE DETECTOR IS LOCATED ON THE WALL NEAR THE ENTRANCE TO THE 'C' MAKE-UP PUMP (SOUTH TNTRANCE). Tl!E REDAS ,

SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-27 A

Q SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 12

'O .

EMCLQSURE.1 (Page 11 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 puprrrrxx l l GAMMA RADIATION g l HIGH I I I I EVENT POINT 1768 INDICATED CONDITION:

o RM-Gil RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-C11 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-Gil MONITORS THE DEBORATING DEMIN ROOM. THE DETECTOR IS LOCATED WALL ALSO BE INSIDE THE DEMIN USED TO OBSERVE TREND ROOM ON THE 119' ELEVATION. THE REDAS SYSTEM MAY INFORMATION,

REFERENCES:

DRAWING 208-049-RM-27 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 13

I I

l O ENCLOSURE 1 '

(Page 12 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 l l GAMMA g l RADIATION g l HIGH I I I I EVENT POINT 1770 INDICATED CONDITION:

o l'.M-G12 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G12 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o IN'IESTICATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G12 MONITORS THE SPENT RESIN STORAGE TANK ROOM. THE DETECTOR IS LOCATED IN THE DECANT AND SLURRY PUMP ROOM JUST INSIDE THE LOCKED CATE ON THE WALL. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-28 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 14

i 1-ENCLOSURE 1 (Page 13 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H 01-01 l l

I I

,I GAMMA l MADIATION g l HIGH I I I I ,

EVENT POINT 1772 INDICATED CONDITION:

o RM-G13 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G13 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G13 MONITORS THE DECONTAMINATION PIT AREA. THE DETECTOR IS LOCATED O THE 143' ELEVATION, CLOSE TO THE STAIRWELL BY THE ECSTs. THE RED %S SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-28 SENSING ELEMENT:= RADIATION MONITORING PANEL AR-403 Rev. 28 Page 15

ENCLQSURE 1 (Page 14 of 190) i FSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 pr rrrx--

l GAMMA y

RADIATION y

HIGH ,

I I

J EVPNT POINT 1774 INDICATED CONDITION:

o RM-G14 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G14 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS UR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G14 MONITORS THE SPENT FUEL STORACE AREA. THE DETECTOR IS LOCATED ON THE 143' AB, ON THE WALL OF THE REACTOR BUILDING IN THE PASSAGEWAY TO THE SPENT FUEL SYSTEM FILTERS. THIS DETECTOR IS THE ONLY S.T.S. AREA MONITOR AND IS COMMONLY REFERRED TO AS THE " SPENT FUEL CRITICALITY MONITOR". THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

O

REFERENCES:

DRAWING 208-049-RM-29 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 16 e

,(

l ENCLOSURE 1 (Page 15 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 l %ZZZZZZ I l  ; GAMMA g  ; RADIATION g l HIGH I I I I EVENT POINT 1776 INDICATED CONDITION:

o RM-G15 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

O h REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G15 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGtTE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o IF FUEL MOVEMENT IS IN PROGRESS. ENSURE FUEL IS PLACED IN A SAFE CONDITION PRIOR TO PERSONNEL EXIT.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G15 MONITORS THE SPENT FUEL AREA. THE DETECTOR IS LOCATED ON THE SPENT FUEL BRIDGE AND MOVES WITH THE BRIDGE. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION,

REFERENCES:

DRAWING 208-049-RM-29 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 17

I O . ENCLOSURE 1 (Page 16 of 190)

_ PSA-Z AN'"NCIATOR RESPONSE PSA-Z-01-01 H-01-01 6

I g GAMMA l RADIATION

[ HIGH l

I J EVENT POINT 1778 INDICATED CONDITION:

o RM-G16 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G16 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR AGIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFEGED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o IF FUEL MOVEMENT IS IN PROGRESS, ENSURE FUEL IS PLACED IN A SAFE CONDITION PRIOR TO PERSONNEL EXIT.

o REFER TO OP-505. RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G16 MONITORS THE FUEL TRANSFER AREA. THE DETECTOR IS LOCATED ON THE ,

MAIN FUEL BRIDGE AND MOVES WITH THE BRIDGE. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-30 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 18

I l

p

- ENCLOSURE 1 (Page 17 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 l l OAMMA y  ; RADIATION l

)

l HIGH  !

I I I I EVENT POINT 1780 INDICATED CONDITION:

o RM-G17 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G17 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G17 MONITORS THE 119' ELEVATION OF THE REACTOR BUILDING. THE DETECTOR IS LOCATED ON THE STANCHION HEAR THE PERSONNEL HATCH. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-30 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page _9

ENCLOSURE 1 Os (Page 18 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-01 H-01-01 i l

W '

GAMMA

g. l RADIATION l l HIGH i I I I I h

EVENT POINT 1782 INDICATED CONDITION:

o RM-G18 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDAf'T INDICATION WHICH WILL VERIFY ALARM:

j o RM-G18 IhDICATION AT RADIATION MONITORING PANEL.

l OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS /RECORDEP,5 FOR TREND INFORMATION.

o VERIFY FRANSFER CANAL LEVEL AT DESIRED HEIGHT.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G18 MONITORS THE INCORE PIT AREA THE DETECTOR IS LOCATED IN THE PIT ON THE 164' ELEVATION NEAR THE TRANSFER CANAL. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 205-049-RM-31 SENSING ELEMENT: RADIATION MONITORING PANEL 4

AR-403 Rev. 28 Page 20

_ _ _ = _ _ _ _ _ _ _ _ . . . . _ . . - . . _ . _. _. ._. .

d

, {s ENCLOSURE 1 (Pt.ge 19 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-01 H-01-01 l l GAMMA g l RADIATION  !

g l HIGH I I I I EVENT POINT 1784 INDICATED CONDITION

o RM-G29/30 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

r REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G29/30 INDICATION ON HVAC SECTION OF MAIN CONTROL BOARD.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

  • DISCUSSION:

RM-G29/30 ARE THE REACTOR BUILDING HIGH RANGE POST ACCIDENT MONITORS.

THE DETECTORS ARE LOCATED ON THE TOP OF EACH 'D' RING AT THE 180' ELEVATION. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-32

-[

SENSING ELEMENT- RADIATION MONITORING PANEL AR-403 Rev. 28 Page 21

ENCLOSURE 1 lO (Page 20 of 190) t PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 t

1 GAMMA MONITOR WARNING EVENT POINT 1749 l INDICATED CONDITION:

o RM-G1 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR i

o RM-G1 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

4 o RM-G1 INDICATION AT RADIATION MONITORING PANEL.

o RM-G1 INDICATION AT DETECTOR.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

, o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

d DISCUSSION:

RM-G1 MONITORS THE CONTROL ROOM. THE DETECTOR IS ON THE BACK WALL NEXT i' TO THE ES RELAY ACTUATION CABINETS. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION,

REFERENCES:

DRAWING 208-049-RM-22 SENSING ELEMENT: RADIATION MONITORING PANEL j AR-403 Rev. 28 Page 22

~

ENCLOSURE 1 (Page 21 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1751 INDICATED CONDITION:

o RM-G2 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR, RM-G2 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G2 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:-

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

.o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-C2 MONITORS THE CHEMICil LABORATORY. THE DETECTOR IS LOCATED ON THE EAST WALL INSIDE THE CHEMICAL LABORATORY. EITHE't WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-23

( SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 23

O ENCLOSURE 1 (Page 22 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1753 INDICATED CONDITION:

o RM-G3 RADIATION LEVEL EXCEEDS WARNING SETPOIKT OR, o RM-G3 RADIATION MONITOR FAILED LOW.

O) y REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G3 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G3 MONITORS THE PRIMARY SAMPLE ROOM. THE DETECTOR IS LOCATED ON THE WALL INSIDE THE PRIMARY SAMPLE ROOM. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEA MAY ALSO BE USED TO OBSERVE TPEND INFORMATION.

')

REFERENCES:

DRAWING 208-049-RM-23 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 24

ENCLOSURE 1 g (Page 23 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1755 INDICATED CONDITION:

o RM-G4 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR, o RM-G4 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G4 -INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G4 MONITORS THE AUXILIARY BUILDING ENTRANCE HALLWAY. THE DETECTOR IS LOCATED ON THF WALL OPPOSITE THE PAX PHONE NEAR THE ENTRANCE TO THE INTERMEDIATE d'JILDING. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO-OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-24 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 25

g ENCLOSURE 1 (Page 24 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1757 INDICATED CONDITION:

o RM-G5 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR, o RM-GS RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-GS INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G5 MONITORS THE WASTE GAS TANK VALVE ALLEY. THE DETECTOR IS LOCATED ON THE WALL OPPOSITE THE WASTE GAS COMPRESSOR ROOM. EITHER WARNING SETPOINT EXCEEDED OR A DETECTCA FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-24 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 26

ENCLOSURE 1 (Page 25 of 190)-

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR V!ARNING EVENT POINT 1759 INDICATED CONDITION:

o RM-G6 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G6 RADIATION MONITOR FAILED LOW.

RED'JNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G6 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEAL 1H PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G6 MONITORS THE MAKEUP TANK VALVE ALLEY. THE DETECTOR IS LOCATED ON THE WALL NEAR THE ENTRANCE LOCKED GATE. EITHER WARNING SETPOINT EXCEEDED OR 4 DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-25 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 27

i O ENCLOSURE 1 V (Page 26 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 l

GAMMA MONITOR WARNING EVENT POINT 1761 INDICATED CONDITION:

o RM-G7 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G7 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G7 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G7 MONITORS THE RC BLEED TANK AREA. THE DETECTOR IS LOCATED ON T NEAR THE ENTPANCE INSIDE THE LOCKED CATE ON THE 95' ELEVATION. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS A THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-25 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 28

l i

ENCLOSURE 1

\

(Page 27 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 i

t GAMMA MONITOR WARNING r

EVENT POINT 1763 i

INDICATED CONDITION:

o RM-G8 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G8 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G8 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR' ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G8 MONITORS THE RC BLEED TANK AREA. THE DETECTOR IS LOCATED ON THE WALL NEAR THE ENTRANCE INSIDE THE LOCKED GATE ON THE 119' ELEVATION. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM.

THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-26

( SENSING ELEMENT: RADIATION MONITORING PANEL t

AR-403 Rev. 28 Page 29

/'

ENCLOSURE 1 (Page 28 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING l

EVENT POINT 1765 INDICATED CONDITION:

o RM-G9 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G9 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G9 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G9 MONITORS THE PERSONNEL HATCH. THE DETECTOR IS LOCATED ON THE WALL NEAR THE ENTRANCE INSIDE THE LOCKED CATE ON THE 119' ELEVATION. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM.

THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-26 A SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 30

ENCLOSURE 1

.O')

.LJ (Page 29 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 l

i GAMMA

-- MONITOR WARNING i

l EVENT POINT 1767 INDICATED CONDITION:

o RM-G10 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G10 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G10 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S) o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G10 MONITORS NEAR THE ENTRANCE THE TO THE 'C'MAKE-UP PUMP AREA. THE DETECTOR IS LOCATED ON THE W MAKE-UP PUMP (SOUTH ENTRANCE). EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE RE SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION,

REFERENCES:

DRAWING 208-049-RM-27 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 31

ENCLOSURE 1 (Page 30 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 I

GAMMA MONITOR WARNING l __

EVENT POINT 1769 l

INDICATED CONDITION:

o RM-Gil RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-Gil RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-Gil INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIG'l RADIATION OR,-

MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITCRING SYSTEM.

DISCUSSION:

RM-Gli MONITORS THE DEB 0 RATING DEMIN ROOM. THE DETECTOR IS LOCATED ON THE WALL INSIDE THE DEMIN ROOM ON THE 119' ELEVATION. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-27 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 32

p ENCLOSUR(_1 i

g (Page 31 of 190)

, PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 l j I a

i I

GAMMA MONITOR WAe4NING 1 EVENT POINT 1771 1

INDICATED CONDITION:

o RM-G12 RADIATION LEVEL EXCEEDS WARNING SETPOIlfT OR o RM-G12 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G12 INDICATION AT RADIATION MONITORING PANEL.

i 4

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR.

MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFEGED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND IUORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G12 MONITORS THE SPENT RESIH STORAGE TANK ROOM. THE DETECTOR IS LOCATED IN THE DECANT AND SLURRY PUMP ROOM JUST INSIDE THE LOCKED CATE. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM.

THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-28 e i Q SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 33

_ _ _ _ . .. - _ _ . _ . - - _ _ _ _ _ _ _ _ _ _ _ _ _ . _ . _ ~ _ _ _ . _ _ _ _ _ _

-~

+ ENCLOSURE 1 (Page 32 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1773 INDICATED CONDITION:

o RM-G13 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G13 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G13 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFEGED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEP.

DISCUSSION:

RM-G13 MONITORS THE DECONTAMINATION PIT AREA. THE DETEGOR IS LOCATED ON

~ THE 143' ELEVATION, CLOSE TO THE STAIRWELL BY THE ECSTs. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-28 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 34

ENCLOSURE 1 (Page 33 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 l

GAMMA MONITOR WARNING EVENT POINT 1775 INDICATED CONDITION:

o RM-G14 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G14 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G14 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARF:

o INVESTICATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G14 MONITORS THE SPENT FUEL STORAGE AREA. THE DETECTOR IS LOCATED ON THE 143' AB, ON THE WALL OF THE REACTOR BUILDING IN THE PASSAGEWAY TO THE SPENT FUEL SYSTEM FILTERS. THIS DETECTOR IS COMMONLY REFERRED TO AS THE

" SPENT FUEL CRITICALITY MONITOR". THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-29 O

V SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 35 i

1 I

l l

l O EMCLOSURE 1 (Page 34 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING EVENT POINT 1777 INDICATED CONDITION:

o RM-G15 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G15 RADIATION MONITOR FAILED LOW.

REDUNDANT I NICATION WHICH WILL VERIFY ALARM:

o RM-G15 IbOICATION AT RADIATION MONITORING PANEL.

OPERATOR AGIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G15 MONITORS THE SPENT FUEL AREA THE DETEGOR IS LOCATED ON THE SPENT FUEL BRIDGE AND MOVES WITH THE BRIDGE. EITHER WARNING SETPOINT EXCEEDED OR A DETEGOR FAILED LOW WILL GIVE THIS ALARM. THE REUAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-29 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 36

ENCLOSURE 1 O- (Page 35 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 I

(

GAMMA MONITOR WARNING EVENT POINT 1779 INDICATED CONDITION:

o RM-G16 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G16 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G16 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFEGED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G16 MONITORS THE FUEL TRANSFER AREA. THE DETECTOR IS LOCATED ON THE MAIN FUEL BRIDGE AND MOVES WITH THE BRIDGE. EITHER WARNING SETPOINT EXCEEDED OR A DETEGOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYS MAY ALSO BE USED TO OBSERVE TRENL' INFORMATION.

REFERENCES:

DRAWING 208-049-RM-30 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 37

C)

'(,/

ENCLOSURE 1 (Page 36 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02

'i GAMMA MONITOR WARNING EVENT POINT 1781 INDICATED CONDITION:

o RM-G17 RADIATION LEVEL EXCEEDS WARNING SETPOINT OR o RM-G17 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G17 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAPSE OF HIGH RADIATION OR, MONITOR LOW READING.

c NOTIFY HEALTH PHYSICS TO ONITOR AFFECTED AREACS).

o OBSERVE AREA MONITORS / REC 0ADERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G17 MONITORS THE 119' ELEVATION OF THE REACTOR BUILDING. THE DETECTOR IS LOCATED ON THE STANCHION NEAR THE PERSONNEL HATCH. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION,

REFERENCES:

DRAWING 208-049-RM-30

( SENSING ELEMENT: RADIATION MONITORING . '.EL AR-403 Rev. 28 Page 38

- ~. _

i EliCLOSURE 1 U (Page 37 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-02 H-01-02 GAMMA MONITOR WARNING I

EVENT POINT 1783 I

INDICATED CONDITION:

o RM-G18 RADIATION LEVEL EXCEEDS WARNING SETPOINT CR o RM-G18 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G18 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR, MONITOR LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S).

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o VERIFY TRANSFER CANAL LEVEL AT DESIRED HEIGHT.

o REFER ~ TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G18 MONITORS THE INCORE PIT AREA. THE DETECTOR IS LOCATED IN THE PIT ON THE 164' ELEVATION NEAR THE TRANSFER CANAL. EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-31

[ SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 39

r

/ ENCLOSURE 1 (Page 3F of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-02 H-01-02 i

GAMMA MONITOR WARNING l

EVENT POINT 1785 INDICATED CONDITION:

o RM-G29/30 RADIATION LEVEL EXCEEDS WARNING SETPOINT(S) OR o RM-G29/30 RADIATION MONITOR (S) FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G29/30 INDICATION ON HVAC SECTION OF MAIN CONTROL BOARD.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID A!. ARM:

o INVESTIGATE CAUSE OF HIGH RADIATION OR MONITOR (S) LOW READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (S),

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o VERIFY TRANSFER CANAL LEVEL AT DESIRED HEIGHT, o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G29/30 ARE THE REACTOR BUILDING HIGH RANGE POST ACCIDENT MONITORS.

THE DETECTORS ARE LOCATED ON THE TOP OF EACH 'D' RING AT THE 180' ELEVATION EITHER WARNING SETPOINT(S) EXCEEDED OR A DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREN INFORMATION.

REFERENCES:

DRAWING 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 40

1 i

p ENCLOSURE 1 l Q (Page 39 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-01-05 H-01-05 MN STM LINE A/B HIGH RAD MONITOR Fall EVENT POINT 1977 INDICATED CONDITION:

o RM-G25/26/27/28 RADIATION LEVEL EXCEEDS ALARM SETPOINT, OR o RM-G25/26/27/28 RADIATION MONITOR FAILED LOW.

(

Q REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-G25/26/27/28 INDICATION ON HVAC SECTION OF MAIN CONTROL BOARD.

o AUDIBLE INDICATION ON RADIATION MONITOR (S) o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION OR LOW MONITOR READING.

o NOTIFY HEALTH PHYSICS TO MONITOR AFFECTED AREA (5),

o REFER TO E0P-06, STEAM GENERATOR TUBE RUPTURE.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-G25/28 MONITOR THE ATMOSPHERIC DUMP LINES MSV-25/A1 AND MSV-26/B2.

RM-G26/27 MONITOR THE MAIN STEAM LINES B1 AND A2 RESPECTIVELY. THE DETECTORS ARE ALL LOCATED ON THE 119' ELEVATION OF THE INTERMEDIATE BUILDING ON THEIR RESPECTIVE STEAM LINE. EITHER RADIATION SETPOINT EXCEEDED OR A DETECTOR FAILED LOW CAN GIVE THIS ALARM.

[ REFERENCES- DRAWING 208-049-RM-47 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 41

( ENCLOSURE 1 (Page 40 of 190)

PSA-Z ANNUNCIA10R RESPONSE PSA-2-01-07 H-01-07 i

DO STOR TANK LEVEL HIGH/ LOW l o.-

EVENT POINT 1512 INDICATED CONDITION:

o DO STORACE TANK LEVEL >97* H,0 AS SENSED BY D0-4-LS O.

Q REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH LEVEL.

o NOTIFY SECONDARY PLANT OPERATOR TO OBSERVE LOCAL LEVEL INDICATOR.

DISCUSSION:

TH6 00 STORAGE TANK HAS AN AUTO FILL FEATURE. IF THE LEVEL IS HIGH AND RISING THE FILL VALVE MAY BE STUCK OPEN.

REFERENCES:

DRAWING 208-022-D0-07 SENSING ELEMENT: DO-4-LS AR-403 Rev. 28 Page 42

1

.p) i V

ENCLOSURE 1 (Page 41 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-01-07 H-01-07 DO STOR TANK LEVEL HIGH/ LOW l EVENT POINT 1520 1

INDICATED CONDITION:

o DO STORAGE TANK LEVEL <33" H,0 AS SENSED BY 00-3-LS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

+

OPERATOR ACTIONS FOR A VALID ALARM:

, o INVESTIGATE CAUSE OF LOW LEVEL.

o NOTIFY SECONDARY PLANT OPERATOR TO OBSERVE LOCAL LEVEL INDICATOR.

1 DISCUSSION:

THE DO STORAGE TANK HAS AN AUTO FILL FEATURE. IF THE LEVEL IS LOW AND NOT RISING THE FILL VALVE MAY BE STUCK CLOSED, OR DO WATER FROM UNITS 1/2 WATER TREATMENT BUILDING IS NOT AVAILABLE. CONTACT UNITS 1/2 TO INVESTIGATE.

REFERENCES:

DRAWING 208-022-00-07 SENSING ELEMENT: DO-3-LS AR-403 Rev. 28 Page 43

, . _ _ _ .. _ _ . ____. _ ~ ._ _ ...~. _ _ _ _ _ _ . _ _ _. . _ . _ _ . _-. ___ _ _ ___ _ _ _ . .__ ___.._._ _ .

i-a ENCLOSURE 1 (Page 42 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 s

l ATMOSPHERIC l l RADIATION -

l l HIGH l l I I EVENT POINT 1712 INDICATED CONDITION:

o RM-Al RADIATION LEVEL EXCEEDS HIGH SETPOINT.

A V REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-Al INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-250, o INVESTIGATE CAUSE OF HIGH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-Al MONITORS THE REAGOR BUILDING PURGE EXHAUST DUCT. THREE DIFFERENT DETEGORS ARE USED, PARTICULATE, IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSEkVE TREND INFORMATION,

REFERENCES:

DRAWING 208-049-RM-16 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 44 5

p

+

ENCLOSURE 1 (Page 43 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-01 H-02-01 I

l l ATMOSPHERIC l l RADIATION l l HIGil l I I I EVENT POINT 1715 INDICATED CONDITION:

o RM-A2 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VhRIFY ALARM:

o RM-A2 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PACE.

OPERATORAbTIONSFORAVALIDALARM:

o REFER TO AP-250.

o INVESTIGATE CAUSE OF HIGH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A2 MONITORS THE AUXILIARY BUILDING PURGE EXHAUST DUCT. THREE DIFF DETECTORS ARE US D, PARTICULATE, IODINE AND GAS. ANY ONE OF THESE CHANNELS CAM GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TRE INFORMATION.

REFERENCES:

DRAWING 208-049-RM-16

(,/

SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 45

.. ~ - - - _ _ .- .. . - __

q ENCLOSURE 1 (Page 44 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 l ATMOSPHERIC l l RADIATION l l HIGH I I l l EVENT POINT 1718 INDICATED CONDITION:

o RM-A3 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

(O y REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A3 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-250, o INVESTIGATE CAUSE OF HIGH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A3 MONITORS AUXILIARY BUILDING EXHAUST FROM SAMPLE AREA 'D', THE WASTE GAS COMPRESSOR ROOM, THE WASTE GAS VALVE ALLEY, AND ADJOINING AREAS. TH15 DETECTOR ONLY HAS A CAS CHANNEL. THE REDAS SYSTEM t'AY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-17

.O y' SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 46

-- - . . . . . - .-. .. . . -- _ . - _- . - .~ - - -

ENCLOSURE 1 (Page 45 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 4

a l

I

, ATMOSPHERIC l RADIATION l HIGH l

I 1

EVENT POINT 1721 i

IN ICATED CONDITION:

o RM-A4 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

O ty REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A4 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-250.

o INVESTIGATE CAUSE OF HIGH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A4 MONITORS THE SPENT FUEL AREA EXHAUST. THIS DETECTOR ONLY HAS A GAS CHANNEL. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-17 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 47

i lt l

ENCLOSURE 1 (Page 46 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-01 H-02-01 4

l l ' )

l l

, ATMOSPHERIC l -* ,l RADIATION

~

l l HIGH l I

,_ _ l I EVENT POINT 1724 INDICATED CONDITION:

o RM-A5 RADIATION LEVEL EXCEEDS HICH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A5 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PACE.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-250.

o INVESTICATE CAUSE OF HICH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A5 MONITORS THE CONTROL COMPLEX RETURN DUCT. THREE DIFFERENT DETECT ARE USED. PARTICULATE. IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN CIV THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCESI DRAWING 208-049-RM-18 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 48

ENCLO10RE 1 (Page 47 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01

, H-02 01 i I -

I

~ ATMOSPHERIC l l RADIATION l  ;

HIGH i I l I I I EVENT POINT 1727 INDICATED CONDITION:

o RM-A6 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM o - RM-A6 INDICATION AT RADIATION MONITORING PANEL, o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM; o INVESTICATE CAUSE OF HICH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE. SAMPLE POINTS ARE EITHER AHF-38 DUCT, OR THE RB ATMOSPHERE DIRECTLY.

THE DUCT OF AHF-38. IT IS NORMALLY LINED UP TO IT CAN ALTERNATELY BE LINED UP TO SAMPLE THE RB ATMOSPHERE DIRECTLY PER OP-417. TWO DIFFERENT DETECTORS ARE USED, PARTICULATE ALARM. / IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN CIVE THIS THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-18 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 49

O ENCLOSURE 1 (Page 48 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 l l ATMOSPHERIC

l RADIATION l l HIOH I i l I EVENT POINT 1730 INDICATED CONDITIONt o RM-A7 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM o RM-A7 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A7 MONITORS THE AHF-44A/B DISCHARGE AIR, THEREFORE THE ATMOSPHERES OF THE PRIMARY SAMPLE ROOM, PRIMARY SAMPLE ROOM SAMPLE HOOD, RADIO CHEMISTRY LAB SAMPLE HOODS, AND/OR PASS SYSTEM VALVE ALLEY MAY HAVE HIGH CASE 0VS ACTIVITY THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMA

REFERENCES:

DRAWING 208-049-RM-19 O SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 50

t 1

O ENCLOSURE 1 (Page 49 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-01 H-02-01 l l ATMOSPHERIC l l RADIATION l l HIGH l

~

l l l l EVENT POINT 1733 INDICATED CONDITION:

o RM-A8 RADIATION LEVEL EXCEEDS HICH SETPOINT, hDUNDANT INDICATION WHICH WILL VERIFY ALARMt o RM-A8 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HICH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505. RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A8 MONITORS THE AUXILIARY BUILDING EXHAUST UPSTREAM OF ThE PENETRAT FOR THE OBSERVE FUEL TREND HANDLING FLOOR EXHAUST THE REDAS SYSTEM MAY ALSO BE U INFORMATION.

REFERENCES:

DRAWING 208-049-RM-19 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 51

O ENCLOSURE 1 (Page 50 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-01 H-02-01 l l ATMOSPHERIC RADIATION l

] l HIGH I I I I EVENT POINT 1736 INDICATED CONDITION:

o RM-All RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-All INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o IF WASTE CAS RELEASE IN PROGRESS, NOTIFY PRIMARY PLANT OPERATOR TO ENSURE WGDT RECYCLE VALVES AND RELEASE VALVE ARE CLOSED.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-All MONITORS THE AUXILIARY BUILDING EXHAUST PENETRATION FOR THE WAS CAS RELEASE PATH. THE WCDT RECYCLE VALVES ARE WDV AND THE 393/394/395 RELEASE TREND VALVE INFORMATION, IS WDV-439. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE

REFERENCES:

DRAWING 208-049-RM-20 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 52

ENCLOSL'RE 1 (Page 51 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-01 H-02-01 1

per r r r - -

l l ATMOSPHERIC RADIATION

__- I I $$g .x. . -- HIGH I I ..,. u. _ _ -

1 I L

EVENT POINT 1738 INDICATED CONDITION:

o RM-A12 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A12 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE.

o MAIN STEAM LINE RAD MONITORS RMC-25, RMG-?G, RMG-27, AND /OR RMC-28 READ HIGHER THAN NORMAL.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-06 STEAM GENERATOR TUBE RUPTURE.

o INVESTIGATE CAUSE OF HIGH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A12 MONITORS THE AUXILIARY BUILDING EXHAUST PENETRATION FOR SECON PLANT TREND CONDENSER OFF CAS. THE REDAS SYSTEM MAY ALSO BE L' SED TO OBSERV INFORMATION.

REFERENCES:

DRAWINC 208-049-Rf4-20 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 53

ENCLOSURE 1 (Page $2 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-01 H-02-01 l

l l ATMOSPHERIC l l RADIATION l l HIGH I I I I EVENT POINT 1742 INDICATED CONDITION:

o RM-A14 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A14 INDICAT7.ON AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o OESERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505. RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A14 IS A PORTABLE MONITOR, NORMALLY LOCATED NEAR THE PRIMARY SAMPLE LABORATORY. THIS MONITOR IS NOT NORMALLY ENERGIZED. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-21 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 54

i B CLOSURE 1 v (Page 53 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-01 H-02-01 l l -

ATMOSPHERIC l l RADIATION l [ HIGH I I I I EVENT POINT 1745 INDICATED CONDITION:

o RM-A15 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A15 INDICATION AT RADIATION MON.*E' RING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A15 IS A PORTABLE MONITOR, NORMALLY LOCATED NEAR THE DECONTAMINATION PIT ON THE SPENT FUEL FLOOR. THIS MONITOR IS NOT NORMALLY ENERGIZED. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-22 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 55

l l

l ENCLOSURE 1 (Page 54 of 190)

PSA Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 ATMOSPHERIC l MONITOR WARNING EVENT POINT 1713 INDICATED CONDITION:

o RM-Al RADIATION LEVEL EXCEEDS WARNING SETPOINT. OR o RM-Al RADIATION MONITOR FAILED LOW REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-Al INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-Al MONITORS THE REACTOR BUILDING PURGE EXHAUST DUCT. THREE DIFFEREN DETECTORS ARE USED, PARTICULATE, IODINE AND CAS ANY ONE OF THESE CHANNELS CAN GIVE THIS ALARM, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-16 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 56

ENCLOSURE 1 (Page 55 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 ATMOSPH.itlC MONITCR WARNING EVENT POINT 1714 INDICATED CONDITION:

o RM-Al RADIATION MONITOR PUMP FLOW ABOVE NORMAL DE LESS THAN 5 SCFM.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-Al FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505. RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-Al MONITORS THE REACTOR BUILDING PURGE EXHAUST DUCT. THREE DIFFERE DETECTORS ARE USED, PARTICULATE, IODINE AND CAS. EITHER A HIGH OR LOW FLOW CAN GIVE THIS ALARM.

REFERENCES:

DRAWING 208-049-RM-01 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 57

_____---.---------------r -

1 1

ENCLOSURE 1 (Page 56 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1716 INDICATED CONDITION:

o RM-A2 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A2 RADIATION MONITOR FAILED LOW

/~'

\

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A2 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505 RADIATION MONITORING SYSTEM. '

DISCUSSION:

RM-A2 MONITORS THE AUXILIARY BUILDING PURGE EXHAUST DUCT. THREE DIFFER DETECTORS ARE USED, PARTICULATE, IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN GIVE THIS ALARM, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION

REFERENCES:

DRAWINC 208-049-RM-16 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 58

ENCLOSURE 1 (Page 57 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1717 INDICATED CONDITION:

o RM-A2 RADIATION MONITOR PUMP FLOW ABOVE NORMAL OR LESS THAN 5 SCFM.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A2 FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RAD. ATION MONITORING SYSTEM.

DISCUSSION:

RM A2 MONITORS.THE AUXILIARY BUILDING PURCE EXHAUST DUCT. THREE DIFFERENT DEiECTORS ARE USED, PARTICULATE. IODINE AND CAS. EITHER A HIGH OR LOW FLOW CAN GIVE THIS ALARM.

REFERENCES:

DRAWING 208-049-RM-02 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 59

i

! ENCLOSHRE_1 (Page 58 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1719 '

INDICATED CONDITION:

o RM-A3 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A3 RADIATION MONITOR FAILED LOW REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A3 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

  • DISCUSSION:

RM-A3 MONITORS AUXILIARY BUILDING EXHAUST FROM SAMPLE AREA

'D', THE WASTE CAS COMPRESSOR ROOM, THE WASTE CAS VALVE ALLEY, AND ADJOINING AREAS. THIS DETECTOR ONLY HAS A CAS CHANNEL AND EITHER WARNING SETPOINT EXCEEDED OR DETECTOR FAILED LOW WILL CIVE THIS ALARM. THE F.EDTS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-16 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 6s L

Ig INCLQSURE 1 (Page 59 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 l H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1720 INDICATED CONDITION:

t o RM-A3 RADIATION MONITOR PUMP FLOW ABOVE NORMAL QB LESS THAN 5 SCFM.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A3 FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A3 MONI')R.C AUXILIARY BUILDING EXHAUST FROM SAMPLE AREA'D', THE WASTE GAS COMP"; .SOR POOM THE WASTE GAS VALVE ALLEY, AND ADJOINING AREAS. THIS DETECT THIS ALARM.0k ( XLY HAS A GAS CHANNEL AND EITHER A HIGH OR LOW FLOW CAN GIVE

REFERENCES:

DRAWING 208-049-RM-03 SENSING ELEMENT: RADIATION MONITORING PANEL AR-dO3 Rev. 28 Page 61 L

l ENCLOSURE 1 (Page 60 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 l

_,~

ATMOSPHERIC MONITOR WARNING EVENT POINT 1722 INDICATED CONDITION:

o RM-A4 RADIAT40N LEVEL EXCEEDS WARNING SETPOINT, OR o RM A4 RADIATION MONITOR FAILED LOW REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A4 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505. RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A4 MONITORS THE SPENT FUEL AREA EXHAUST. THIS DETECTOR ONLY HAS A GA CHANNEL AND EITHER WARNING SETPOINT EXCEEDED OR A DETECTOR FAILED LO GIVE INFORMATION.

THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND

REFERENCES:

DRAWING 208-049-RM-17 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 2B Page 62

ENCLOSURE 1 (Page 61 of 190)

PEA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 l

l ATMOSPHERIC MONITOR WARNING l

(

EVENT POINT 1723 INDICATED CONDITION:

o RM-A4 RADIATION MONITOR PUMP FLOW ABOVE WRML QB LESS THAN 5 SCFM.

REDUNDt.NT INDICATION WHICH WILL VERIFY ALARM:

o RM-A4 FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A4 MONITORS THE SPENT FUEL AREA EXHAUST. THIS DETECTOR ONLY HA CHANNEL AND EITHER A HIGH OR LOW FLOW CAN GIVE THIS ALARM.

REFERENCES:

DRAWING 208-049-RM-04 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 63 L

l l

!(

l ENCLOSURE 1 (Page 62 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1725 INDICATED CONDITION:

o RM-A5 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A5 RADIATION MONITOR FAILED LOW REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A5 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A5 MONITORS THE CONTROL COMPLEX RETURN DUCT. THREE DIFFERENT DETEC ARE USED, PARTICULATE. IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN GIVE THIS ALARM, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-18 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 64

ENCLOSURE 1 (Page 65 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-01-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1726 INDICATED CONDITION:

o RM-AS RADIATION MONITOR PUMP FLOW A30VE NORMAL QB LESS THAN 5 SCFM.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A5 FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-/3 MONITORS THE CONTROL COMPLEX RETURN DUCT. THREE DIFFERENT DETECTOR ARE U55.0, PARTICULATE, IODINE AND CAS. EITHER A HICH OR LOW FLOW CAN GIVE THIS A'_ ARM.

REFERENCES:

DRAWING 208-049-RM-05 SENSING ELEMENT; RADIATION MONITORING PANEL l

AR-403 Rev. 28 Page 65

ENCLOSURE 1 (Page 64 of 190)

PSA-Z ANNUNCIATOR RESPONSE pSA.Z-02-02 H-02-02 EE ATMOSPHERIC MONITOR WARNING l

EVENT POINT 1728 INDICATED CONDITION:

o RM-A6 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A6 RADIATION MONITOR FAILED LOW O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A6 INDICATION AT RADIATION MONITORING PANEL.

9 SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM. -

DISCUSSION:

RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE. SAMPLE POINTS ARE EITHER AHF-3B DUCT, OR THE RB ATMOSPHERE DIRECTLY.

DUCT OF AHF-38. IT IS NORMALLY LINED UP TO THE IT CAN ALTERNATELY BE LINED UP TO SAMPLE THE Rb DIRECTLY PER OP-417. ATMOSPHERE TWO DIFFERENT DETECTORS ARE USED, PARTICULATE / IODINE AND CAS. ANY ONE OF THESE CHANNELS CAN GIVE THIS ALARM.

THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION,

REFERENCES:

DRAWING 208-049-RM-18 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 66

ENCLOSURE 1 (Page 65 of 190)

~

PSA-Z ANNUNCIATOR RESPONSE PSA-ZII02 0 H-02-02 ATMOSPHERIC MONITOR  !

WARNING EVENT POINT 1729 INDICATED CONDITION:

o RM-A6 RADIATION MONITOR PUMP FLOW ABOVE NORMAL LESS THAN 5 SCFM, OR RMA-6 BACKUP SAMPLE PUMP IS RUNNING.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A6 FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

EITHER A HIGH OR LOW FLOW CAN CIVE THIS ALARM.

RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE. SAMPLE POINTS ARE EITHER AHF-3B DUCT, OR THE RB ATMOSPHERE DIRECTLY, THE DUCT OF AHF-3B. IT IS NORMALLY LINED UP TO IT CAN ALTERNATELY BE LINED UP TO SAMPLE THE RB ATMOSPHERE DIREGLY PER OP-417.

TWO DIFFERENT DETECTORS ARE USED, PARTICULATE / IODINE AND CAS. ant' ONE OF THESE CHANNELS CAN CIVE THIS ALARM.

O THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-66 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 67

ENCLOSURE 1

(

(Page 66 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1731 INDICATED CONDITION:

o RM-A7 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A7 RADIATION MONITOR FAILED LOW REDUNDANT INDICATION WHICH WILL VERIFY ALARM o RM-A7 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM o INVESTIGATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORAATION.

REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A7 MONITORS THE AHF-44A/B DISCHARGE AIR, THEREFORE THE ATMOSPHERES OF THE PRIMARY SAMPLE ROOM, PRIMARY SAMPLE ROOM SAMPLE HOOD, RADIO CHEMISTRY LAB SAMPLE HOODS, AND/0R PA3S SYSTEM VALVE ALLEY MAY HAVE HIGH GASEOUS ACTIVITY, THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-19 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403- Rev. 28 Page 68

(~ ENCLOSURE 1 (Page 67 of 190)

_ PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1732 INDICATED CONDITION:

o RM-A7 RADIATION MONITOR PUMP FLOW ABOVE NORMAL QB LESS THAN 5 SCFM, REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM A7 FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

EITHER A HIGH OR LOW FLOW CAN CIVE THIS ALARM. RM-A7 MONITORS THE AHF-44A/B DISCHARGE AIR, THEREFORE THE ATMOSPHERES OF THE PRIMARY SAMPLE ROOM, PRIMARY SAMPLE ROOM SAMPLE HOOD, RADIO CHEMISTRY LAB SAMPLE HOODS, AND/OR PASS SYSTEM VALVE ALLEY MAY HAVE HIGH GASEOUS ACTIVITY. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-07 SENSING ELEilENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 69

ENCLOSURE 1 (Page 68 of 190) i PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1734 INDICATED CONDITION:

o RM-A8 RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A8 RADIATION MONITOR FAILED LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A8 INDICATION AT RADIATION MNITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

  • DISCUSSION:

RM-A8 MONITORS THE AUXILIARY BUILDING EXHAUST UPSTREAM OF THE PENETRATIO FOR THE FUEL HANDLING FLOOR EXHAUST. THIS DETECTOR ONLY HAS A GAS CHANNE AND, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW WILL GIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-16 D

\j SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 70

{NCLOSURE 1 (Page 69 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 ATMOSPHERIC MONITOR WARNING EVENT POINT 1735 INDICATED CONDITION:

o RM-A8 RADIATION MONITOR PUMP FLOW ABOVE N00tAL QB LESS THAN 5 SCFM.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A8 FLOW INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF RADIATION PUMP FLOW PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-A8 MONITORS THE AUXILIARY BUILDING EXHAUST UPSTREAM OF THE PENETRATION FOR THE FUEL HANDLING FLOOR EXHAUST. THIS DETECTORS ONLY HAS A GAS CHANN AND, EITHER A HIGH OR LOW FLOW CAN GIVE THIS ALARM.

REFERENCES:

DRAWING 208-049-RM-08 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 71

![ ENCLOSURE 1 (Page 70 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 1

I ATMOSPHERIC MONITOR WARNING EVENT POINT 1737 INDICATED CONDITION:

o RM-All RADIATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-All RADIATION MONITOR FAILED LOW REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-All INDICATION AT RADIITION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION, OR LOW MONITOR READING.

o OBSERVE AREA MONITORS / RECORDERS FOR TREND INFORMATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

RM-All MONITORS THE AUXILIARY BUILDING EXHAUST PENETRATION FOR THE WASTE GAS RELEASE PATH. THIS DETECTOR ONLY HAS A GAS CHANNEL AND, EITHER WARNING SETPOINT EXCEEDED, OR DETECTOR FAILED LOW CAN CIVE THIS ALARM. THE REDAS SYSTEM MAY ALSO BE USED TO OBSERVE TREND INFORMATION.

REFERENCES:

DRAWING 208-049-RM-20 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 72

ENCLOSURE 1 (Page 71 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-02 H-02-02 l  :

l ATMOSPHERIC MONITOR WARNING EVENT POINT 1739 INDICATED CONDITION:

o RM-A12 RAD? ATION LEVEL EXCEEDS WARNING SETPOINT, OR o RM-A12 RADIATION MONITOR FAILED LOW REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-A12 INDICATION AT RADIATION MONITORING PANEL.

o MAIN STEAM LINE RAD MONITORS RMG-2!.. RMG-26, RMG-27, AND/OR RMG-28 READ HIGHER THAN NORMAL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF RADIATION MONITOR PROBLEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

o o CHECK ARV-26/27 FOR PROPER POSITION (ARP-1A/18 3-WAY VALVES)

REFER TO CP-152. PRIMARY TO SECONDARY LEAKAGE OPERATING GUIDELINE DISCUSSION:

RM-A12 MONITORS THE AUXILIARY BUILDING EXHAUST PENETRATION FOR SECONDA PLANT CONDENSER OFF GAS. THIS DETECTOR ONLY HAS A CAS CHANhEL AND, EITHER WARNING SETPOINT EXCEEDED OR DETECTOR FAILED LOW CAN GIVE THIS ALARM.

CHECK FOR SUPPORTING INDICATIONS OF OTSC TUBE LEAKAGE.

REFERENCES:

DRAWING 208-049-RM-20 p SENSING ELEMENT: RADIATION MONITORING PANEL U

AR-403 Rev. 28 Page 73

l ENCLOSURE 1 (Page 72 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-04 H-02-04 EDAS l SYSTEM

_ TROUBLE EVENT POINT 2045 INDICATED CONDITION:

o LOSS OF MULTIPLEXER POWER.

o PRIMARY METEOROLOGICAL TOWER ON BACKUP POWER.

o PRIMARY METEOROLOGICAL TOWER BACKUP POWER OUT OF SYNCHRONIZATION.

O o PRIMARY METEOROLOGICAL TOWER SIGNAL FAILURE.

o PRIMARY METEOROLOGICAL TOWER BUILDING TEMPERATURE HIGH/ LOW.

REDUNDANT INDICATION WHICH WILL VERIFY ALAR 4:

o PRIMARY METEOROLOGICAL ALARM PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

REFERENCES:

DRAWING 208-070-MM-01 SENSING ELEMENT: MMP-3 METEOROLOGICAL ALARM PANEL AR-403 Rev. 28 Page 74

I ENCLOSURE 1 l

(Page 73 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-05 H-02-05 1

COND PUMP PIT SUMP LEVEL Hl0H I

EVENT POINT 1329 INDICATED CONDITION:

o CONDENSATE PUMP PIT SUMP A LEVEL >88.6' ELEVATION AS SENSED BY SD-31-LS.

l lO l

REDUNDANT INDICATION WHICH WILL VERIFY ALARM

l OPERATOR ACTIONS FOR A VALID ALARM:

l o REFER TO AP-1050.

o NOTIFY SECONDARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION.

/

DISCUSSION:

1 i

i

REFERENCES:

DRAWING 208-072-50-07 SENSING ELEMENT: SD-31-LS O

AR-403 Rev. 28 Page 75

t ENCLOSURE 1 ,

(Page 74 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-05 H-02-05 l

l l

l COND PUMP PIT l -

SUMP LEVEL HIGH i

l EVENT POINT 1317 INDICATED CONDITION:

o CONDENSATE PUMP PIT SUMP B LEVEL >88.6' ELEVATION AS SENSED BY SD-32-LS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TL AP-1050, o NOTIFY SECONDARY PLANT OPERATOR TO INVESTIGATE CAUSE OF ALARM CONDIT DISCUSSION:

REFERENCES:

DRAWING 208-072-SD-08 SENSING ELEMENT: SD-32-LS O

AR-403 Rev. 28 Paoa 76

5 ENCLOSURE 1 (Page 75 of 190)

PSA-Z ANNUNCIATOR RESPONSE I PSA-2-02-06 H-02-06

_ ew .4 l

I AUX BLDG SUMP LEVEL HIGH EVENT POINT 1292 INDICATED CONDITION:

o DECAY HEAT PIT SUMP A LEVEL >74' ELEVATION AS SENSED BY WD-133-LS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM: .

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

REFERE.4CES: DRAWING 208-060-WD-09 SENSING ELEMENT: WD-133-LS AR-403 Rev. 28 Page 77

ENCLOSURE 1 (Page 76 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-06 H-02-06 l

AllX BLDG SUMP LEVEL

HIGH l

EVENT POINT 1305 INDICATED CONDITION:

o DECAY HEAT PIT SUMP B LEVEL >74' ELEVATION AS SENSED BY WD-134-LS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION.

DISCUSSION:

REFERENCES:

DRAWING 208-060-WD-10 SENSING ELEMENT: WD-134-LS AR-403 Rev. 28 Page 78

(~ ENCLOSUREJ

( (Page 77 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-06 H-02-06 AUX BLDG SUMP LEVEL HIGH EVENT POINT 1300 INDICATED CONDITION:

o AUXILIARY BUILDING SUMP LEVEL >92.5' ELEVATION AS SENSED BY WD-132-LS.

i O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION.

DISCUSSION:

REFERENCES:

DRAWING 208-060-WD-12 l SENSING ELEMENT: WD-132-LS

,O v

AR-403 Rev. 28 Page 79 L.

[ ENCLOSURE 1 (Page 78 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-06 H-02-06 i

AUX BLDG SUMP LEVEL HIGH EVENT POINT 1809 INDICATED CONDITION:

o NUCLEAR SERVICE COOLER AREA SUMP >93'1" ELEVATION AS SENSED BY SD-5-LS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o THIS LEVEL SWITCH IS A MECHANICAL ALTERNATOR WHICH OPERATES BOTH SDP-2A AND 2B.

SWITCH #1 STARTS THE LEAD PUMP AT 93'0" AND SWITCH #2 STARTS THE LAG PUMP AT 93'1" AND INITIATES THE HIGH LEVEL ALARM.

REFERENCES:

DRAWING 208-072-5D-03 7 SENSING ELEMENT: SD-5-LS

)

AR-403 Rev. 28 Page 80

n ENCLOSURE 1

( (Page 79 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-06 H-02-06 l AUX BLDG SUMP LEVEL HIGH l EVENT POINT 1810 INDICATED CONDITION:

o TENDON ACCESS GALLERY SUMP >71'1" ELEVATION AS SENSED BY SD-6-LS.

i O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o THIS LEVEL SWITCH IS A MECHANICAL ALTERNATOR WHICH OPERATES BOTH SDP-3A AND 38.

SWITCH #1 STARTS-THE LEAD PUMP AT 71'0" AND SWITCH #2 STARTS THE LAG PUMP AT 71'1" AND INITIATES THE HIGH LEVEL ALARM.

REFERENCES:

DRAWING 208-072-50-05 O SENSING ELEMENT: SD-6-LS AR-403 Rev. 28 Page 81

ENCLOSURE 1 (Page 80 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 I

BLDG SUMPS SUMP PUMP TROUBLE l

EVENT POINT 1198 INDICATED CONDITION:

o DIESEL GENERATOR SUMP A/B LEVEL HIGH AS SENSED BY EG-027-LS, O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDI DISCUSSION:

REFERENCES:

DRAWING 208-027-EG-17 SENSING ELEMENT: EG-027-LS.

O AR-403 Rev. 28 Page 82

O fELOSURE __1 (Page 81 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 l

BLDG SUMPS SUMP PUMP TROUBLE EVENT POINT 1586 INDICATED CONDITION:

o DECAY HEAT PIT SUMP PUMP AUTO START.

o DECAY HEAT PIT SUMP PUMP TRIP, O

v REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF ALARM CONDITION.

DISCUSSION:

THIS ALARM MAY INDICATE AN AUTO SHUT DOWN IF THE PRIMARY PLANT OPERATOR MANUALLY STARTED THE DECAY HEAT PIT SUMP PUMP. THE ALARM IS BASED ON THE PUMP CONTROL SWITCH CONTACTS (NORMAL AFTER START OR NORMAL AFTER STOP)

IN SERIES WITH THE SUMP LEVEL SWITCH.

REFERENCES:

DRAWING 208-060-WD-09, WD-10 WD-134 SENSING ELEMENT: WD-133-LS, WD-134-LS, WDP-3A/3B CONTROL SWITCH CONTACTS.

AR-403 Rev. 28 Page 83

m ENCLOSURE 1 (Page 82 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 i

BLDG SUMPS SUMP PUMP TROUBLE EVENT POINT 1587 INDICATED CONDITION:

o AUXILIARY BUILDING SUMP PUMP AUTO START.

o AUXILIARY BUILDING SUMP PUMP TRIP.

o $'ASTE CAS COMPRESSOR SEAL LEAKAGE DRAIN TANK LOW LEVEL.

O U

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o DURING NORMAL OPERATING CONDITIONS, THIS IS AN EXPECTED ALARM WHENEVER THE AUX. BLDG. SUMP PUMP AUTO STARTS; IF ALARM DOES NOT CLEAR WITHIN 3-5 MINUTES, THEN NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE CAUSE OF ALARM CONDITION.

o ENSURE WDV-1030-SV HAS CLOSED (SEAL TANK DRAIN POT DRAIN VALVE).

DISCUSSION:

THIS ALARM MAY INDICATE AN AUTO SHUT DOWN IF THE PRIMARY PLANT OPERATOR MANUALLY STARTED THE AUXILIARY BUILDING SUMP PUMP (S). THE ALARM IS BASED ON THE PUMP CONTROL SWITCH CONTACTS (NORMAL AFTER START /STOP) IN SERIES WITH THE SUMP LEVEL SWITCH. THE WASTE CAS COMPRESSOR SEAL LEAKAGE DRAIN TANK CAN GIVE THIS ALARM BY OPERATING WDV-1030-SV TO LOWER THE DRAIN TANK LEVEL UNTIL THE LOW LEVEL SWITCH CONTACT OPENS. (SEE DRAWING WD-175) t

REFERENCES:

DRAWINC 208-060-WD-11, WD-12, WD-135, WD-175 k

SENSING ELEMENT: WD-132-LS, WD-357-LS2, WDP-4A/4B CONTROL SWITCH CONTACTS.

AR-403 Rev. 28 Page 84

.t ENCLOSURE 1 (Page 83 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 BLDG SUMPS SUMP PUMP TROUBLE EVENT POINT 1589 INDICATED CONDITION:

o LAUNDRY AND SHOWER SUMP PUMP AUTO START.

o LAUNDRY AND SHOWER SUMP PUMP TRIP, I

O Q ,/

REDUNDANT INDICATION WHI!H WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A V/t.ID ALARM:

DISCUSSION:

REFERENCES:

SENSING ELEMENT:

O AR-403 Rev. 28 Page 85 T _____

h

' O

' ENCLOSURE 1 V (Page 84 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 BLDG SUMPS SUMP PUMP TROUBLE I

EVENT POINT 1806 INDICATED CONDITION:

o DIESEL GENERATOR ROOM 'A' SUMP LEVEL HIGH AS SENSED BY SD-19-LS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTICATE CAUSE OF HIGH LEVEL.

DISCUSSION:

REFERENCES:

DRAWING 208-072-5D-15.

SENSING ELEMENT: SD-19-LS AR-403 Rev. 28 Page 86

ENCLOSURE 1 (Page 85 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 BLDG SUMPS SUMP PUMP l

- TROUBLE EVENT POINT 1807 INDICATED CONDITION:

o DIESEL GENERATOR ROOM 'B' SUMP LEVEL HIGH AS SENSED BY SD-20-LS.

bG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO INVESTIGATE CAUSE OF HIGH LEVEL.

DISCUSSION:

REFERENCES:

DRAWING 208-072-5D-16.

SENSING ELEMENT: SD-20-LS AR-403 Rev. 28 Page 87

.p. ENCLOSURE 1 (y (Page 86 of 190)

(

I PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-07 H-02-07 BLDG SUMPS SUMP PUMP TROUBLE l

EVENT POINT 1811 INDICATED CONDITION:

o INTAKE ELECTRIC VAULT SUMP LEVEL HICH AS SENSED BY SD-14-LS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY SECONDARY PLANT OPERATOR TO INVESTICATE CAUSE OF HICH LEVEL.

DISCUSSION:

REFERENCES:

ORAWING 208-072-SD-09.

SENSING ELEMENT: S D-14-LS O

AR-403 Rev. 28 Page 88

ENCLOSURE 1 ,

(Page 87 of 190) {

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 BLDG SUMPS SUMP PUMP TROUBLE I

EVENT POINT 1880 INDICATED CONDITION:

o TURBINE ROOM SUMP LEVEL HIGH AS SENSED BY SD-24-LS QB o OILY WATER SEPARATOR TROUBLE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY SECONDARY PLANT OPERATOR TO INVESTIGATE CAUSE OF HIGH LEVEL AND/OR OILY WATER SEPARATOR PROBLEM DISCUSSION:

OILY WATER SEPARATOR TROUPLE MAY BE CAUSED BY ANY OF THE FOLLOWING:

HIGH/ LOW VACUUM PRE-FILTER HIGH AP OIL DISCHARGE EMERGENCY STOP WHEN IN AUTO THE ALARM WINDOW DOES NOT TYPE "0ILY WATER SEPARATOR TROUBLE" BUT IN FACT IS LABELED " TURBINE BUILDING SUMP LEVEL HIGH".

REFERENCES:

DRAWING 208-072 SD-01, SD-17.

SENSING ELEMENT: SD-24-LS, SD-24-DPIS, SD-26-PIS AR-403 Rev. 28 Page 89

i ENCLOSURE 1 (Page 88 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-02-07 H-02-07 BLDG SUMPS l

SUMP PUMP 1

TROUBLE 1

EVENT POINT 1913 INDICATED CONDITION:

o SEWAGE PUMP SUMP LEVEL HIGH AS SENSED BY LOCAL CIRCUIT.

%J REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o SEP-1A AND/OR SEP-1B RUNNING.

OPERATOR ACTIONS FOR A VALID A'LARM:

o NOTIFY TURBINE BUILDING OPERATOR TO ENSURE LEVEL DOES NOT OVERFLOW ONT TURBINE BUILDING FLOOR AND THAT SEP-1A AND OR SEP-1B ARE RUNNING TO LOWER LEVEL.

DISCUSSION:

REFERENCES:

DRAWING 208-064 ME-10 SENSING ELEMENT: R1.

AR-403 Rev. 28 Page 90

~

ENCLOSURE 1

( (Page 89 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-08 H-02-08 l

SEC SAMPLE l SYSTEM ALARM EVENT POINT 0798 l

INDICATED CONDITION:

o HOTWELL/ CONDENSATE CONDUCTIVITY HIGH, O

V REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o SS-141-CIR, CONDUCTIVITY RECORDER ON HVAC SECTION OF MCB.

o COMPUTER POINTS A-100 TO A-104.

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY o REFER TOSECONDARY CP-138 CHEMISTRY TO INVESTIGATE CAUSE OF HIGH CONDUCTIVITY.

DISCUSSION:

REFERENCES:

DRAWING 208-054-55-10 SENSir4G ELEMENT: SS-141-CIR O

AR-403 Rev. 28 Page 91

~

ENCLOSURE 1 (Page 90 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-02-08 H-02-08 SEC SAMPLE SYSTEM ALARM EVENT POINT 0887 INDICATED CONDITION:

o SECONDARY CYCLE SAMPLE ANALYSIS ALARM.

10 V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY SECONDARY CHEMISTRY TO INVESTICATE CAUSE OF SAMPLE ALARM.

DISCUSSION:

THIS ALARM INDICATES AN ALARM HAS NOT BEEN ACKNOWLEDGED IN THE SECONDA CHEMISTRY LABORATORY WITHIN AN ADJUSTABLE TIMER SETTING.

REFERENCES:

DRAWING 208-054-55-11 SENSING ELEMENT: SSCP-1 (SECONDARY CYCLE SAMPLE ANALYZER PANEL)

AR-403 Rev. 28 Page 92

ENCLOSURE 1 (Page 91 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-03-01 H-03-01 I I LIQUID l l RADIATION l [ HIGH l l l l l 1

EVENT POINT 1786 INDICATED CONDITION:

o RM-L1 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

O rO REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L1 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

s

REFERENCES:

DRAWING 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 93

ENCLOSURE 1 (Page 92 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-01 H-03-01 l

,I LIQUID g l RADIATION l l HIGH l I I I EVENT POINT 1788

(

INDICATED CONDITION:

o RM-L2 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

O V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L2 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o o NOTIFY PRIMARY PLANT OPERATOR TO ENSURE WDV-891 AND WDV-892 CLOSED.

REFER TO OP-505, RADIATION MONITORING SYSTEM.

o CONTACT CHEMISTRY FOR EVALUATION OF MONITOR PRIOR TO MONITOR FLUSH.

DISCUSSION:

WDV-891 AND WDV-892 ARE PRIMARY LIQUID RELEASE VALVES.

REFERENCES:

DRAWING 208-049-RM-31 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 94

ENCLOSURE 1 y (Page 93 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-03-01 H-03-01 ,

w i

r xrrr i I LIQUID l l RADIATION

, l HIGH I I l l EVENT POINT 1792' l INDICATED CONDITION:

i o

RM-L3 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

O REDUNDANT INDICATION W'ICH WILL VERIFY ALARM:

o RM-L3 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM.

o REFER TO OP-408, NUCLEAR SERVICES COOLING SYSTEM TO CONNECT SW SURCE TANK TO WASTE GAS HDR o REFER -T0 OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-32 i

SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 95

ENCLOSURE 1

( (Page 94 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-03-01 H-03-01 Z P'F====

I I

! LIQUID l l RADIATION l l HIGH I l l I EVENT POINT 1794 INDICATED CONDITION:

o RM-L5 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

O O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L5 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 96

[- ENCLOSURE 1 (Page 95 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-03-01 H-03-01 r w l l xrrr LIQUID l l RADIATION

' l l HIGH I I I I EVENT POINT 1796 INDICATED CONDITION:

o RM-L6 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L6 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

O

\. d SENSING ELEMENT:

DRAWING 208-049-RM-32 RADIATION MONITORING PANEL AR-403 Rev. 28 Page 97

ENCLOSURE 1 (Page 96 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-01 H-03-01 r perrrrr I I

' LIQUID l  ; RADIATION l l HIGH I I I I EVENT POINT 1798 INDICATED CONDITION:

o RM-L7 RADIATION LEVEL EXCEEDS HIGH SETPOINT.

A U

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L7 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PACE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o NOTIFY PRIMARY PLANT OPERATOR TO ENSURE SDV-90 CLOSED.

o CONTACT CHEMISTRY FOR EVALUATION OF MONITOR PRIOR TO MONITOR FLUSH.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

SDV-90 IS THE SECONDARY LIQUID RELEASE VALVE.

REFERENCES:

DRAWING 208-049-RM-31 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 98

O ENCLOSURE 1 (U (Page 97 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-02 H-03-02

! LIQUID MONITOR WARNING l

EVENT POINT 1787 INDICATED CONDITION:

o RM-L1 RADIATION LEVEL EXCEEDS WARNING SETPOINT.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM; o RM-L1 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-32 t%

Q SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 99

l

( ENCLOSURE 1 (Page 98 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-03-02 H-03-02 LIQUID MONITOR WARNING I

EVENT POINT 1789 I

INDICATED CONDITION:

o RM-L2 RADIATION LEVEL EXCEEDS WARNING SETPOINT.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L2 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HIGH RADIATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-31 10

\.) SEN5ING ELEMENT: RADIATION MONITORING PANEL AR-40's Rev. 28 Page 100

('] ENCLOSURE 1

() (Page 99 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-02 H-03-02 LIQUID MONITOR WARNING g

EVENT POINT 1791 INDICATED CONDITION:

o RM-L3 RADIATION LEVEL EXCEEDS WARNING SETPOINT.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L3 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REAGOR COOLANT SYSTEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 101

i ENCLOSURE 1 (Page 100 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-02 H-03-02 LIQUID MONITOR WARNING 1

EVENT POINT 1795 i

t INDICATED CONDITION:

o RM-L5 RADIATION LEVEL EXCEEDS WARNING SETPOINT.

O V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L5 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 102

O V

ENCLOSURE 1 (Page 101 of 190)

PSA-Z ANNUNCIATOR RESPONSE DSA-Z-03-02 H-03-02 l

LIQUID MONITOR i WARNING EVENT POINT 1797 l

l l INDICATED CONDITION:

o RM-L6 RADIATION LEVEL EXCEEDS WARNING SETPOINT.

fk REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L6 INDICATION AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-301, OPERATION OF THE REACTOR COOLANT SYSTEM.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-32 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 103

l ENCLOSURE 1

.. (Page 102 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-03-02 H-03-02 i

LlOUlD MONITOR WARNING EVENT POINT 1799 INDICATED CONDITION:

o RM-L7 RA01ATION LEVEL EXCEEDS WARNING SETPOINT.

O O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RM-L7 INDICATION AT RADIATION MONITORING PANEL.

o SPDS ALPHA PAGE.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH RADIATION.

o REFER TO OP-505, RADIATION MONITORING SYSTEM.

DISCUSSION:

REFERENCES:

DRAWING 208-049-RM-31 SENSING ELEMENT: RADIATION MONITORING PANEL AR-403 Rev. 28 Page 104

O ENCLOSAlfLL1 (Page 103 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-03-03 H-03-03 1

P i

RM L2/7 INTERLOCK BYPASSED EVENT POINT 2044 INDICATED CONDITION:

o INTERLOCK BETWEEN SDV-90 AND RWP-3A/3B DEFEATED.

o INTERLOCK BETWEEN WDV-892 AND RWP-1, RWP-2A/2B DEFEATED.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM o RM-L2/7 BYPASS KEY INSTALLED AT RADIATION MONITORING PANEL.

OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

BYPASSING THE RM-L2/7 INTERLOCK ALLOWS OPENING OF SDV-90 WITH EITHER RWP-1, RWP-2A OR RWP-28 RUNNING INSTEAD OF RWP-3A OR RWP-38. ALSO WDV-892 MAY BE OPENED WITH RWP-3A OR RWP-3B RUNNING INSTEAD OF RWP-1, RWP-2A OR RWP-28.

REFERENCES:

DRAWING 208-060-WD-60 SENSING ELEMENT: RADIATION MONITORING PANEL BYPASS INTERLOCK KEY SWITCH AR-403 Rev. 28 Page 105 s- - m

O ENCLOSURE 1 (Page 104 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-01 H-04-01 l l MAKEUP TANK

; LEVEL l l l LOW LOW I I I I EVENT POINT 0792 I

INDICATED CONDITION:

o MAKEUP TANK LEVEL <18' AS SENSED BY MU14-LYI-4, MU14-LY2-4.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MU 014-LIR1, MUT LEVEL / PRESSURE RECORDER.

o MU-14-LI1, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL).

o MU-14-LI2, MUT LEVEL INDICATION (REDUNDART INSTRUMENT PANEL).

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE MUV-58, AND MUV-73 OPEN.

o RESTORE MAKEUP TANK LEVEL TO NORMAL BAND.

DISCUSSION:

REFERENCES:

DRAWING 208-041-MU-17,MU-18 SENSING ELEMENT: MU14-LY1-4,MU14-LY2-4.

AR-403 Rev. 28 Page 106

i ENCLOSURE 1 (Page 105 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-02 H-04-02

- MAKEUP TANK LEVEL HIGHILOW EVENT POINT 1064 INDICATED CONDITION:

o MAKEUP TANK LEVEL >100" AS SENSED BY MU-14-LY3. '

O V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM o MU-014-LIR1, MUT LEVEL / PRESSURE RECORDER, o MU-14-LII, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL).

o MU-14-LI2, MUT LEVEL IWDICATION (REDUNDANT INSTRUMENT PANEL).

o COMPUTER POINT X359 OPERATOR ACTIONS FOR A VALID ALARM:

o RESTORE MAKEUP TANK LEVEL TO NORMAL BAND.

DISCUSSION:

IF MVP(S) ARE ALIGNED TO BWST & RECIRC FLOW TO MUT IS CAUSING HICH LEVEL IN MUT, THEN CONSIDER ALIGNING MVP SUCTION FROM MUT ONLY.

REFERENCES:

DRAWING 208-041-MU-47.

SENSING ELEMENT: MU-14-LY3.

AR-403 Rev. 28 Page 107

O ENCLOSURE 1 (Page 106 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-02 H-04-02 0

MAKEUP TANK LEVEL Hl0HILOW EVENT POINT 1065 INDICATED CONDITION:

o MAKEUP TANK LEVEL <55' AS SENSED BY MU-14-LY3.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MU-014-LIR1, MUT LEVEL / PRESSURE RECORDER.

o MU-14-LI1, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL).

o MU-14-LI2, MUT LEVEL INDICATION (REDUNDANT INSTRUMENT PANEL).

o COMPUTER POINT X359.

OPERATOR ACTIONS FOR A VALID Al ARM:

o RESTORE MAKEUP TANK LEVEL TO NORMAL BAND.

DISCUSSION:

REFERENCES:

DRAWING 208-041-MU-47.

SENSING ELEMENT: MD-14-LY3.

AR-403 Rev. 28 Page 108

ENCLOSURE 1 (Page 107 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-03 H-04-03 MAKEUP j FLOW HIGH EVENT POINT 1066 INDICATED CONDITION:

o MAKEUP FLOW >160 GPM THROUGH MUV-31 AS SENSED BY MU-24-FS.

O .

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MU-24-FI OPERATOR ACTIONS FOR A VALID ALARM:

o DETERMINE CAUSE OF HIGH FLOW ALARM.

o OBSERVE LTOP CONCERNS o REFER TO OP-301 DISCUSSION:

THE HIGH FLOW ALARM WAS ESTABLISHED FOR LTOP CONDITIONS TO PROVIDE INDICATION SHOULD MUV-31 FAIL WIDE OPEN. THE INTENT WAS TO PROVIDE AT LEAST 10 MINUTES FOR OPERATOR CORRECTIVE ACTION FOR THIS TRANSIENT.

REFERENCES:

DRAWING 208-041-MU-47.

SENSING ELEMENT: MU-24-FS.

AR-403 Rev. 28 Page 109

t

[ELOSURE 1 (Page 108 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-04 H-04-04 LETDOWN TEMP H10H EVENT POINT 1027 INDICATED CONDITION o LETDOWN TEMPERATURE TO PRE-FILT5RS >130*F AS SENSED BY MU-5-TS.

O V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MU-$-TI OPERATOR ACTIONS FOR A VALID ALARM:

o REDUCE LETDOWN FLOW WITH MUV-51 FLOW CONTROL VALVE.

o NOTIFY COOLERS PRIMARY

' SEALED'. PLANT OPERATOR TO VERIFY SW THROTTLE VALVES TO LETDOWN DISCUSSION:

IF LETDOWN HAS ISOLATED VIA MVV-49 REFER TO OP-402 FOR LETDOWN RECOVERY IF HIGH LETDOWN FLOW IS DESIRED THEN CONSIDER STARTING SWP-1A OR SWP-1 PROVIDE ADDITIONAL COOLING WATER TO THE LETDOWN COOLERS.

REFERENCES:

DRAWING 208-041-MU-33.

SENSING ELEMENT: MU-5-TS.

AR-403 Rev. 28 Page 110

ENCLOSURE 1 (Page 109 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-05 H 04-05 RC PUMP SEAL BLEED OFF HIGH I

EVENT POINT 1075 INDICATED CONDITION:

o RC PUMP 1A CONTROL BLEEDOFF >1.75 GPM AS CALCULATED BY PLANT COMPUTER.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o COMPUTER POINT X-922.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-302 'RC PUMP OPERATION'.

DISCUSSION:

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

COMPUTER GROUP 78 CONTAINS ADDITIONAL DATA FOR RCP-1A.

REFERENCES:

DRAWING 208-047 RC-05.

SENSING ELEMENT: RX00/RC-19A-PT1 AR-403 Rev. 28 Page 111

O ENCLOSURE 1 (Page 110 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-05 H-04-05 RC PUMP SEAL BLEED OFF HIGH EVENT POINT 1076 INDICATED CONDITION:

o RC PUMP 1B CONTROL BLEED 0FF >1.75 GPM AS CALCULATED BY PLANT COMPUTER.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o COMPUTER POINT X-923.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-302 'RC PUMP OPERATION'.

DISCUSSION:

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

COMPUTER GROUP 79 CONTAINS ADDITIONAL DATA FOR RCP-18.

REFERENCES:

DRAWING 208-047 RC 06.

SENSING ELEMENT: RX01/RC-19A-PT2 AR-403 Rev. 28 Page 112

l l

O -

ERCLOSUPl._1 (Page 111 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-05 H-04-05 RC PUMP l SEAL 8LEED OFF HIGH I

EVENT POINT 1077 INDICATED CONDITION:

o RC PUMP 1C CONTROL BLEEDOFF >1.75 GPM AS CALCULATED BY PLANT COMPUTER.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o COMPUTER POINT X-924.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-302 'RC PUMP OPcRATION'.

DISCUSSION:

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

COMPUTER GROUP 80 CONTAINS ADDITIONAL DATA FOR RCP-1C.

-'N

REFERENCES:

DRAWINC 208-047 RC-07.

(V SENSING ELEMENT: RX02/RC-19B-PT1.

AR-403 Rev. 28 Page 113

O ENCLOSURE 1 (Page 112 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-05 H-04-05 RC PUMP SEAL BLEED OFF HIGH EVENT POINT 1078  !

l INDICATED CONDITION:

o RC PUMP 10 CONTROL 3LEEDOFF >1.75 GPM AS CALCULATED BY PLANT COMPUTER.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o COMPUTER POINT X-925.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-302 'RC PUMP OPERATION'.

DISCUSSION:

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

COMPUTER CROUP 81 CONTAINS ADDITIONAL DATA FOR RCP-10.

REFERENCES:

DRAWING 208-047 RC-08.

SENSING ELEMENT: RX-08/RC-19B-PT1.

AR-403 Rev. 28 Page 114

ENCLOSURE 1 (Page 113 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-7. 04-06 H-04-06 i

\ MAKEUP TANK PRESS Hl0HILOW EVENT POINT 1062 INDICATED CONDITION:

I o COMPUTER.

MAKEUP TANK PRESSURE A THE OVERPRESSURE VALUE CALCULATED BY THE PLANT O

REDUNDANT INDICATION WHICH WILL ucRIFY ALARM:

o MU 014-LIR1, MUT LEVEL / PRES un % CORDER.

o COMPUTER POINTS X359 AND X401.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE MUV-141. MUV-143 CLOSED o

IMMEDIATELY REDUCE PRESSURE WITHIN THE LIMITS OF MAKEUP TANK PRESSURE / LEVEL OF CURVE 8 0F OP-1038.

DISCUSSION:

THE VALUES OF THE COMPUTER POINTS ARE INPUT TO A CALCULATION WHICH ACTUATES THIS EVENT POINT WHEN MUT LfVEL/ PRESSURE COMBINATION ARE BEING OPERATED IN THE RESTRIGED REGION OF CURVE 8 OP-103B,

REFERENCES:

DRAWING 208-041-MU-47.

SENSING ELEMENT: CX82 AR-403 Rev. 28 Page 115 r

l O ENCLOSURE 1 (Page 114 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-06 H-04-06 MAKEUP TANK PRESS HIGHILOW EVENT POINT 1063 INDICATED CONDITION:

o MAKEUP TANK PRESSURE <3 PSIG AS SENSED BY MU-17-PS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MU-014-LIR1, MUT LEVEL / PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE MUV-134 CLOSED o INCREASE OF OP-103B. PRESSURE WITHIN LIMITS OF MAKEUP TANK PRESSURE / LEVEL CURVE DISCUSSION:

MUT PRESSURE MAY BE TEMPORARILY REDUCED BELOW 3 PSIG DURING VENTING EVOLUTIONS, BUT SHOULD BE MAINTAINED AB0VE O PSIC.

REFERENCES:

DRAWING 208-041-MU-47.

SENSING ELEMENT: MU-17-PS.

AR-403 Rev. 28 Page 116

O [RCLOSURE 1 (Page 115 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-07 H-04-07 RC PUMP SEAL RTN (MUV 253)

NOT FULL OPEN EVENT POINT 1036 INDICATED CONDITION:

o MUV-253 NOT FULL OPEN.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MUV-253 VALVE INDICATION ON PSA SECTION AND E.S. LIGHT MATRIX.

o COMPUTER POINT P064.

OPERATOR ACTIONS FOR A VALID ALARM:

o REOPEN MVV-253.

o MONITOR RCP SEALS TEMPERATURE / PRESSURE DISCUSSION:

IF MUV-253 CANNOT BE REOPENED THEN REFER TO OP-302.

RCP DATA CAN BE OBSERVED ON COMPUTER GROUPS 78,79,80 AND 81.

REFERENCES:

DRAWING 208-041-MU-44 SENSING ELEMENT: RELAY 3MUV-2530.

AR-403 Rev. 28 Page 117

O EELMf!L.1 (Page 116 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-08 H-04-08 MAKEUP VALVES I AIR i FAILURE l EVENT POINT 1094 INDICATED CONDITION:

l o LETDOWN FLOW CONTROL VALVE MUV-51 LOCKED.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM o MOV-51 AIR FAILURE PUSH-BUTTON ILLUMINATED.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-470 o INVESTICATE LOSS OF INSTRUMENT AIR PRESSURE TO MUV-51.

DISCUSSION:

WO PRESSURE SWITCHES SUPPLY PRESSURE INFORMATION TO THE CONTROL CIRCUITS FOR MUV-51. MU-3-PS1 SET FOR 32 PSIG AND MU-3-PS2 SET FOR 28 PSIC. IF EITHER MU-3-PS1 OR MU-3-PS2 IS ACTUATED. THE VALVE POSITION WILL BE LOCKED "AS IS" BY THE ISOLATION OF THE AIR LINE FROM THE POSITIONER TO THE VALVE DIAPHRAGM. OPERATION OF THE VALVE BY DEPRESSING THE AIR FAILURE RESET 95H-BUTTON IS NOT CERTAIN AT THIS LOW AIR PRESSURE.

REFERENCES:

DRAWING 208-041-MU-54.

SENSING ELEMENT: MU-3-PSI. MU-3-PS2.

AR-403 Rev. 28 Page 118

I ENCLOSURE 1 (Page 117 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-04-08 H-04-08 l

MAKEUP VALVES AIR FAILURE EVENT POINT 1095 INDICATED CONDITION:

o MAKEUP CONTROL VALVE MUV-31 LOCKED.

REDUNDANT IPDICATION WHICH WILL VERIFY ALARM:

o MUV-31 AIR FAILURE PUSH-BUTTON ILLUMINATED.

o MUV-31 CONTROL STATION IN ' HAND'.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-470 o INVESTICATE LOSS OF INSTRUMENT AIR PRESSURE TO MUV-31.

DISCUSSION:

TWO PRESSURE SWITCHES SUPPLY PRESSURE INFORMATION TO THE CONTROL CIRCUITS FOR MUV-31. MU-25-PS1 SET FOR 32 PSIG AND MU-25-PS2 SET FOR 28 PSIC. IF EITHER MU-25-PS1 OR MU-25-PS2 IS ACTUATED, THE VALVE POSITION WILL BE LOCKED "AS IS" BY THE ISOLATION OF THE AIR LINE FROM THE POSITIONER TO THE VALVE DIAPHRAGM. OPERATION OF THE VALVE BY DEPRESSING THE AIR FAILURE RESET PUSH-BUTTON IS NOT CERTAIN AT THIS LOW AIR PRESSURE.

REFERENCES:

DRAWING 208-041-MU-54.

SENSING ELEMENT: M0-25-PS1,MU-25-PS2.

AR-403 Rev. 28 Page 119

O EELQ!iUfLLI (Page 118 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-04-08 H-04-08  ;

MAKEUP VALVES AIR FAILURE EVENT POINT 1096 INDICATED CONDITION:

o MAKEUP CONTROL VALVE MUV-16 LOCKED.

O V REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MVV-16 AIR FAILURE PUSH-BUTTON ILLUMINATED.

o MUV-16 CONTROL STATION IN ' HAND' .

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-470 o

INVESTIGATE LOSS OF INSTRUMENT AIR PRESSURE TO MUV-16.

DISCUSSION:

Two PRESSURE SWITCHES SUPPLY PRESSURE INFORMATION TO THE CONTROL CIRCUI FOR MUV-16. MU-15-PS1 SET FOR 32 PSIG AND MU-15-PS2 SET FOR 28 PSIG. IF EITHER MU-15-PS1 OR MU-15-PS2 IS ACTUATED, THE VALVE POSITION WIi.L BE LOCKED "AS IS" BY THE ISOLATION OF-THE AIR LINE FROM THE POSITIONER TO THE VALVE DIAPHRAGM. OPERATION OF THE VALVE BY DEPRESSING THE AIR FAILURE RESET PUSH-BUTTON IS NOT CERTAIN AT THIS LOW AIR PRESSURE.

REFERENCES:

DRAWING 208-041-MU-54.

SENSING ELEMENT: MV-15-PS1, MU-15-PS2, AR-403 Rev. 28 Page 120

ENCLOSURE 1 (Page 119 of 190)

PSA-Z ANNUNCI/. TOR RESPONSE PSA-2-04-08 H 04-08 I I I I l l MAKEUP VALVES l l AIR l l FAILURE 2

EVENT POINT 1102 INDICATED CONDITION:

o RC PUMP SEAL BLEEDOFF VALVE MUV-253 AIR SUPPLY PRESSURE <80 PSIG AS SENSED BY MU-253-PS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTION! FOR A VALID ALARM:

o REFER TO AP-470 o INVESTICATE LOSS OF INSTRUMENT AIR PRESSURE TO MUV-253.

DISCUSSION:

OPERATION OF THE VALVE IS NOT CERTAIN AT THIS LOW AIR PRESSURE. MUV-253 FAILS CLOSED IF THE AIR PRESSURE IS INSUFFICIENT AGAINST THE CLOSURE SPRING OF THE VALVE OPERATOR.

REFERENCES:

DRAWING 208-041-MU-54.

SENSING ELEMENT: MU-15-PSI, MU-15-PS2.

AR-403 Rev. 28 Page 121

l l

I ENCLOSilAE_1 (Page 120 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-01 H-05-01 xxr pg---

l l STM GEN A

, l MAIN STEAM ISO l ACTUATED I I I I EVENT POINT 2007 INDICATED CONDITION:

o EFIC CHANNEL "A",

BUS 2 TRIPPED. STEAM GENERATOR "A" MAIN STEAM LINE ISOLATION BUS 1 OR O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP ON FFIC CHANNEL "A" MAIN STEAM LINE ISOLATION.

o MS-106-PI, CHANNEL "A",

OTSG A PRESSURE INDICATION.

o MS-106-PIR.-CHANNEL "A", OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER.

o INVESTIGATE CAUSE OF TRIP CONDITION.

DISCUSSION:

MSLI ACTUATION SETPOINT IS OTSG PRESSURE <600 PSIC. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28 Page 122

\

l l

ENCLOSURE 1 (Page 121 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-01 H-05-01 rrr r l l rr STM GEN A l j MAIN STEAM ISO  ;

l ACTUATED i l

l I

EVENT POINT 2015 INDICATED CONDITION:

o EFIC CHANNEL "B", STEAM GENERATOR BUS 2 TRIPPED. "A" MAIN STEAM LINE ISOLATION BUS 1 OR O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP DN EFIC CHANNEL "B" MAIN STEAM LINE ISOLATION.

o MS-107-PI, CHANNEL "B",

OTSG A PRESSURE INDICATION.

o MS-107-PIR, CHANNEL "B",

OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER.

o INVESTICATE CAUSE OF TRIP CONDITION.

DISCUSSION:

MSLI ACTUATION SETPOINT IS OTSG PRESSURE <600 PSIG. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 2 SENSING ELEMENT:

AR-403 Rev. 28 Page 123 t '

O [NCLOSURE_1 (Page 122 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-02 H-05-02 STM GEN A FEEDWATER 150 ACTUATED L

EVENT POINT 2009 INDICATED CONDITION:

o EFIC CHANNEL "A", STEAM CENERATOR BUS 2 TRIPPED. "A" MAIN FEEDWATER ISOLATION BUS 1 OR O REDUNDANT INDICATION WHICH WILL VERIFY ALARM o HALF OR FULi. TRIP ON EFIC CHANNEL "A" KAIN FEEDWATER ISOLATION.

o MS-106-PI, CHANNEL "A",

OTSC A PRESSURE INDICATION.

o MS-106-PIR, CHANNEL "A",

OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER.

o INVESTICATE CAUSE OF 1 RIP CONDITION.

DISCUSSION:

MFWI ACTUATION SETPOINT IS OTSG PRESSURE <600 PSIC. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS.

REFEkcNCES: VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28- Page 124

l l

O ENCLOSURE 1 (Page 123 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-02 H-05-02 STM GEN A FEEDWATER ISO ACTUATED e EVENT POINT 2017 7 INDICATED CONDITION:

o EFIC CHANNEL "B", STEAM GENERATOR 'A' BUS 2 TRIPPED. MAIN FEEDWATER ISOLATION BUS 1 OR 4,.

O '

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

y o HALF OR FULL TRIP ON EFIC CHANNEL "B" MAIN FEEDWATER ISOLATION.

o MS-107-PI, CHANNEL "B", OTSG A PRESSURE INDICATION, s MS-107-PIR, CHANNEL "B",

OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05 EXCESSIVE HEAT TRANSFER.

o INVESTICATE CAUSE OF TRIP CONDITION.

DISCUSSION:

MFWI ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIC. WITH THIS EVENT POINT

-IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BE1VEEN FULL AND HALF TRIPS.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 2 SENSING ELEMENT:

AR-403 Rev. 28 Page 125

ENCLOSURE 1 (Page 124 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-03 H-05-03 MAIN STEAM ISO VALVE AIR FAILURE

.1 EVENT POINT 0956 INDICATED CONDITION:

o MSV-413 AND MSV-414 AIR SUPPLY PRESSURE <80 PSIG AS SENSED BY MS-99-PS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-470 o INVESTICATE LOSS OF INSTRUMENT AIR Fid53URE TO MSIVs.

DISCUSSION:

ON A LOSS OF INSTRUMENT AIR, THE ACCUMULATORS SHOULD MAINTAIN THE MSIVs OPEN FOR AT LEAST 1 HOUR DEPENDENT ON ACTUATORDECRADATION LEAKAGE. OF THE ACCUMULATOR PRESSURE WILL BE INDICATED BY THE ILLUMINATION OF THE SV-1/SV-2 WHITE TEST LIGHT ON THE PSA PANEL.

REFERENCES:

DRAWING 208-039 MS-14 SENSING ELEMENT: MS-99-PS AR-403 Rev. 28 Page 126

i ENCLOSURE 1 (Page 125 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-03 H-05-03 MAIN STEAM 180 VALVE AIR FAILURE EVENT POINT 0959 INDICATED CONDITION:

o MSV-411 AND MSV-412 t.IR SUPPLY PRESSURE <40 PSIG AS SENSED BY MS 98-PS.

REDUNDANT INDICATION WHI'T WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-470 o

INVESTICATE LOSS OF INSTRUMENT AIR PRESSURE TO MSIVs.

DISCUSSION:

ON A LOSS OF INSTRUMENT AIR, THE ACCUMULATORS SHOULD MAINTAIN THE MSIVs OPEN FOR AT LEAST 1 HOUR DEPENDENT ON ACTUATOR DEGRADATION LEAKACE. OF THE ACCUMULATOR PRESSUP,E WILL BE INDICATED SY THE ILLUMINATION OF THE SV-1/SV-2 WHITE TEST LIGHT ON THE PSA PANEL.

REFERENCES:

DRAWING 208-039 MS-14 SENSING ELEMENT: MS-98-PS AR-403 Rev. 28 Page 127

i i ENCLOSURE 1 (Page 126 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-04 H-05-04 LETDOWN PRESSURE HIGH EVENT POINT 1060 INDICATED CONDITION:

o LETDOWN PRESSURE AFTER BLOCK ORIFICE >145 PSIG AS SENSED BY MU-6-PS.

)

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o COMPUTER POINT X002.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF HICH PRESSURE CONDITION.

o REDUCE LETDOWN FLOW.

DISCUSSION:

A POSSIBLE CAUSE OF HICH PRESSURE AT THIS POINT IN THE SYSTEM IS ISOLATION OF DOWNSTREAM COMPONENTS OR ANY FLOW RESTRICTIONS IN THE PRE-FILTERS, POST-FILTERS OR MAKEUP DEMINS. IF THE HIGH PRESSURE CONDITION EXISTS AND ITS CAUSE CANNOT BE DETERMINED THEN CLOSURE OF MUV-49 MAY BE REQUIRED PREVENT POSSIBLE RELIEF VALVE OPERATION TO THE A.B. SUMP.

REFERENCES:

DRAWING 208-041 MS-47 SENSING ELEMENT: MS-6-PS AR 403 Rev. 2B Page 128

ENCLOSURE 1 (Page 127 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-05 H-05-05 MAKEUP FILTERS APRESS HIGH I

EVENT POINT 1061 INDICATED CONDITION:

o MAKEUP POSTFILTER DIFFERENTIAL PRESSURE >25 PSIG AS SEP SED BY MU-18-DPS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MAKEUP POSTFILTER DIFFERENTIAL PRESSURE MU-18-DPI.

OPERATOR ACTIONS FOR A VALID ALARM:

o PLACE "A" AND "B" POST-FILTERS IN SERVICE.

o REDUCE LETDCMN FLOW.

DISCUSSION:

REFERENCES:

DRAWING 208-041 MU-47 SENSING ELEMENT: MU-18-DPS AR-403 Rev. 28 Page 129

s ENCLOSURE 1

=

(Page 128 of 190) 1 PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-05 H-05-05 MAKEUP FILTERS A PRESS HIGH EVENT POINT 1082 INDICATED CONDITION:

o MAKEUP PRE-FILTER DIFFERENTIAL PRESSURE >12 PSIG AS SENSED BY MU-81-DPS.

i REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o PAKEUP PRE-FILTER DIFFERENTIAL PRESSURE INDICATION MU-81-DPI.

OPERATOR ACTIONS FOR A VALID ALARM:

o PLACE "A" AND "B" PRE-FILTERS IN SERVICE, o REDUCE LETDOWN FLOd.

DISCUSSION:

REFERENCES:

DRAWING 208-041 MU-47 SENSING ELEMENT: MU-81-DPS AR-403 Rev. 28 Page 130

l l

l l ENCLOSURE 1 (Page 129 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-0$-06 H-05-06 1

i MAKEUP DEMIN ,

A PRESS HIGH EVENT POINT 1083 INDICATED CONDITION:

o MAKEUP DEMIN DIFFERENTIAL PRESSURE >14 PSIG AS SENSED BY MU-75-DPS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MAKEUP DEMIN DIFFERENTIAL PRESSURE INDICATION MU-75-DPI.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-402 o

BYPASS DEMINERALIZERS OR PLACE ALTERNATE DEMIN IN SERVICE o REDUCE LETDOWN FLOW DISCUSSION:

CONSIDERATION SHOULO BE GIVEN TO THE AFFECT ON THE RCS OF PLACING THE ALTERNATE DEMIN IN SERVICE. IF IT IS NOT SATURATED AT THE SAME LEVEL AS THE RCS IS AT THE TIME THE ALTERNATE DEMIN IS PLACED IN SERVICE THERE WILL BE A SIGNIFICANT CHANGE IN CORE REACTIVITY THAT MAY CAUSE A SIGNIFICANT OPERATIONAL EXCURSION OR REDUCTION OF THE SHUTDOWN MARGIN.

REFERENCED: DRAWING 208-041 MU-47 O, SENSING ELEMENT: MU-75-DPS

.~

AR-403 Rev. 28 Page 131

4

(-

w ENCLOSURE 1 (Paga 130 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-07 H-05-07 I

RC PUMP SEAL FLOWS HIGHILOW a

EVENT POINT 1079 INDICATED CONDITION:

o REACTOR COOLANT PUMP TOTAL SEAL FLOW >42 GPM AS SENSED BY MU-27-FS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RCACTOR COOLANT PUMP TOTAL SEAL FLOW INDICATION MU-27-FI.

OPERATOR ACTIONS FOR A VALID ALARM:

o - REFER TO OP-302.

o REESTABLISH NORMAL SEAi. FLOW.

DISCUSSION:

REFERENCES:

DRAWING 208-043 MU-47 b

Q SENSING ELEMENT: MU-27-FS AR-403 Rev. 28 Page 132

ENCLOSURE 1 (Page 131 of 190)

PSA-Z ANNUNCIATOR RESr'ONSE PSA-2-05-07 H-05-07 l j RC PUMP SEAL FLOWS HIGH/ LOW .

l 1

l l EVENT POINT 1080 INDICATED CONDITION:

o REACTOR COOLANT PUMP TOTAL SEAL FLOW <22 GPM AS SENSED BY MU-27-FS.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o REACTOR COOLANT PUMP TOTAL SEAL FLOW INDICATION MU-27-FI.

OPERATOR ACTIONS FOR A valid ALARM:

o REFER TO OP-302.

o REESTABLISH NORMAL SEAL FLOW.

DISCUSSION:

REFERENCES:

DRAWING 208-041 MU-47 SENSING ELEMENT: MU-27-FS

.AR-403 Rev. 28 Page 133

ENCLOSURE 1 (Page 132 of 190) j PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-07 H-05 RC PUMP SEAL FLOWS HIGH/ LOW EVENT POINT 1084 INDICATED CONDITION:

o REACTOR COOLANT PUMP 1A SEAL FLOW <3 GPM AS SENSED BY MU-7-FS1.

REDUNDANT INDICATION HICH WILL VERIFY ALARM:

o REACTOR COOLANT PUMP 1A SEAL FLOW INDICATION MU-7-FIl.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-302.

o REESTABLISH NORMAL SEAL FLOW.

DISCUSSION:

REFERENCES:

DRAWING 208-041 MU-47 C# SENSING ELEMENT: MU-7-FS1 AR-403 Rev. 28 Page 134

/']

-(g ENCLOSURE 1 (Page 133 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-07 H-05-07 RC PUMP SEAL FLOWS HIGHILOW EVENT POINT 1085 INDICATED CONDITION:

l o REACTOR COOLANT PUMP 1B SEAL FLOW <3 GPM AS SENSED BY MU-7-FS2.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

I o REACTOR COOLANT PUMP 1B SEAL FLOW INDICATION MU-7-FI2.

OPERATOR ACTIONS FOR A VALID ALARM:

. o REFER TO OP-302, o REESTABLISH NORMAL SEAL FLOW.

DISCUSSION

REFERENCES:

DRAWING 208-041 MU-47 (O) SENSING ELEMENT: MU-7-FS2 AR-403 Rev. 28 Page 135

ENCLOSURE 1 (Page 134 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-07 H-05-07 RC PUMP SEAL FLOWS HIGH/ LOW i

EVENT POINT 1086 INDICATED CONDITION:

o REACTOR COOLANT PUMP 1C SEAL FLOW <3 GPM AS SENSED BY MU-7-FS3.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o REACTOR COOLANT PUMP 1C SEAL FLOW INDICATION MU-7-FI3.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-302.

o REESTABLISH NORMAL SEAL FLOW.

DISCUSSION:

REFERENCES:

DRAWING 208-041 MU-47 SENSING ELEMENT: MU FS3 AR-403 Rev. 28 Page 136

ENCLOSURE 1 (Page 135 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-05-07 H-05-07 l

RC PUMP SEAL FLOWS HIGH/ LOW EVENT POINT 1087 INDICATED CONDITION:

o REACTOR COOLANT PUMP 10 SEAL FLOW <3 CPM AS SENSED BY MU-7-FS4.

1i l

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o REACTOR COOLANT PUMP 1D SEAL FLOW INDICATION MU-7-FI4.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO OP-302.

o REESTABLISH NORMAL SEAL FLOW.

DISCUSSION:

REFERENCES:

DRAWING 208-041 MU-47 SENSING ELEMENT: MU-7-FS4 AR-403 Rev. 28 Page 137

ENCLOSURE 1 (Page 136 of 190) i PSA-Z ANNUNCIATOR RESPONSE PSA-Z-05-08 H-05-08 l

BWST VLV INTERLOCK BYPASSED i EVENT POINT 2048 INDICATED CONDITION:

o MAKEUP TANK LCM-LOW LEVEL INTERLOCK DEFEATED FOR MUV-58 AND/OR MUV-73 O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

SWITCH POSITIONS IN "A" AND "B" REMOTE SHUTDOWN AUXILIARY CABINETS.

OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

THE SWITCH FOR MUV-73 INTERLOCK IS LOCATED IN "A" THE REMOTE SHUTDOWN AUXILIARY CABINET IN THE "A" ES 4160V SWITCHCEAR ROOM. THE SWITCH FOR MUV-58 INTERLOCK IS LOCATED IN THE "B" IN THE "B" REMOTE SHUTDOWN AUXILIARY CABINET ES 4160V AUXILIARY CABINETS.

SWITCHCEAR ROOM. USE S500 KEY 47 TO ACCESS THE

REFERENCES:

DRAWING 205-041 MU-07 SENSING ELEMENT: ZZ SS/BYP, RS-AUX A/B AR-403 Rev. 28 Page 138

ENCLOSURE 1 (Page 137 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-01 H-06-01 I I

,  ; STM GEN B l l MAIN STEAM ISO l l ACTUATED l l I l l

EVENT POINT 2008 l

INDICATED CONDITION:

o EFIC CHANNEL "A", STEAM GENERATOR BUS 2 TRIPPED. "B" MAIN STEAM LINE ISOLATION BUS 1 OR I

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP ON EFIC CHANNEL o MS-110-PI, CHANNEL "A", "A" MAIN STEAM LINE ISOLATION.

OTSG B PRESSURE INDICATION.

o MS-106-PIR, CHANNEL "A",

OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER.

o INVESTIGATE CAUSE OF TRIP CONDITION.

DISCUSSION:

MSLI ACTUATION SETPOINT IS OTSC PRESSURE <600 PSIG. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28 Page 139

q Q ENCLOSURE _1 (Page 138 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-01 H-06-01 l

ZZZZ Z I I STM GEN B l l MAIN STEAM ISO l l ACTUATED l l l l EVENT POINT 2016 INDICATED CONDITION:

o EFIC CHANNEL "B", STEAM CENERATOR BUS 2 TRIPPED. "B" MAIN STEAM LINE ISOLATION BUS 1 OR REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP ON EFIC CHANNEL "B" MAIN STEAM LINE ISOLATION.

o MS-111-PI, CHANNEL "B",

OTSG A PRESSURE INDICATION.

o MS-107-PIR, CHANNEL "B",

OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER.

o INVESTICATE CAUSE OF TRIP CONDITION.

DISCUSSION:

MSLI ACTUATION SETPOINT IS OTSG PRESSURE <600 PSIG. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 2 SENSING ELEMENT:

AR-403 Rev. 28 Page 140

ERCLO1UBL.1

,] (Page 139 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-02 H-06-02 STM GEN B FEEDWATER ISO ACTUATED l

l EVENT POINT 2010 i

INDICATED CONDITION:

o EFIC CHANNEL "A", STEAM CENERATOR BUS 2 TRIPPED. "B" MAIN FEEDWATER ISOLATION BUS 1 OR REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP ON EFIC CHANNEL "A" MAIN FLdDWATER ISOLATION.

o MS-110-PI, CHANNEL "A",

OTSG B PRESSURE INDICATION.

o MS-106-PIR, CHANNEL "A",

OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER.

o INVESTICATE CAUSE OF TRIP CONDITION.

DISCUSSION:

MFWI ACTUATION SETPOINT IS OTSG PRESSURE <600 PSIG. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS.

(J

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28 Page 141

ENCLOSURE 1 (Page 140 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-02 H-06-02 STM GEN B FEEDWATER ISO ACTUATED EVENT POINT 2018 i

INDICATED CONDITION:

o EFIC CHANNEL "B", STEAM GENERATOR BUS 2 TRIPPED. "B" MAIN FEEDWATER ISOLATION BUS 1 OR O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP ON EFIC CHANNEL o MS-111-PI, CHANNEL "B", "B" MAIN FEEDWATER ISOLATION.

OTSG B PRESSURE INDICATION.

o MS-107-PIR, CHANNEL "B",

OTSG A/B PRESSURE RECORDER.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P-05, EXCESSIVE HEAT TRANSFER.

o INVESTIGATE CAUSE OF TRIP CONDITION.

DISCUSSION:

MFWI ACTUATION SETPOINT IS OTSG PRESSURE <600 PSIG. WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS. THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS.

NO ADDITIONAL ALARMS DIFFERENTIATE BETWEEN FULL AND HALF TRIPS.

REFERENCES:

VITRO ORAWING 3801-3005 SHEET 2 SENSING ELEMENT:

AR-403 Rev. 28 Page 142

/~T ENCLOSURE 1 Q (Page 141 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-03 H-06-03 EMERG FW ACTUATION EVENT POINT 2006 INDICATED CONDITION:

o EFIC CHANNEL "A",

EMERGENCY FEEDWATER BUS 1 OR BUS 2 TRIPPED.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP ON EFIC CHANNEL "A" EMERGENCY FEEDWATER ACTUATION.

OPERATOR ACTIONS FOR A VALID- ALARM:

o REFER TO E0P.

o INVESTIGATE CAUSE OF TRIP CONDITION.

DISCUSSION:

WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS.

THE OPERATOR MUST OBSERVE THE EFIC PUSH-BUTTONS TO DETERMINE EFIC ACTUATION STATUS. EFIC ACTUATES BY ANY OF THE FOLLOWING CONDITIONS:

EITHER OTSG <600 PSIG OF ALL RCPs EITHER OTSG APPROACHING 0" MANUAL ACTUATION LOSS NI POWER >45% W/FW <17% HPI A AND B ACTUATION LOSS OF BOTH MFPs W/RPS NOT IN S/D BYPASS

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28 Page 143

ENCLOSURE 1 Os (Page 142 of 190)

PS,\-Z ANNUNCIATOR RESPONSE PSA-2-06-03 H-06-03 EMERG FW ACTUATION l

EVENT POINT 2014 l

INDICATED CONDITION:

o EFIC CHANNEL "B", EMERGENCY FEEDWATER BUS 1 OR BUS 2 TRIPPED.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HALF OR FULL TRIP ON EFIC CHANNEL "B" EMERGENCY FEEDWATER ACTUATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

o INVESTIGATE CAUSE OF TRIP CONDITION.

DISCUSSION:

WITH THIS EVENT POINT IN ALARM, A HALF TRIP OR FULL TRIP CONDITION EXISTS.

THE OPERATOR MUST OBSERVE THE EFIC PUSHBUTTONS TO DETERMINE EFIC ACTUATION STATUS. EFIC ACTUATES BY ANY OF THE FOLLOWING CONDITIONS:

EITHER OTSG <600 PSIG EITHER OTSG APPROACHING 0" MANUAL ACTUATIM LOSS OF ALL RCPs NI POWER >45% W/FW <17% HPI A AND B ACTUATION LOSS OF BOTH MVPs W/RPS NOT IN S/D BYPASS

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28 Page 144

l ENCLOSURE 1 (Page 143 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-04 H-06-04 EF PUMP 1 TRIP DEFEATED i

EVENT POINT 1179 INDICATED CONDITION:

EFP-1 TRIP DEFEAT CONTROL SWITCH IS IN " DEFEAT" POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

VISUAL OBSERVATION OF ONE, TWO, OR THREE EFP-1 TRIP DEFEAT CONTROL SWITCHES IN DEFEAT POSITION. ES ACTUATION TEST CABINETS 1, 2 AND 3 EACH CONTAIN ONE CONTROL SWITCH.

OPERATOR ACTIONS FOR A VALID ALARM:

VERIFY THE REQUIREMENTS FOR PLACING CONTROL SWITCH TO " DEFEAT" ARE MET:

EFP-2 NOT AVAILABLE, FEEDWATER IS REQUIRED, A LOSS OF OFFSITE POWER EVENT IS IN PROGRESS AND LPI INITIATION IS IMMINENT OR HAS OCCURED DISCUSSION:

ESAS CENERATES A TRIP SIGNAL TO-EFP-1 WHEN AS RCS LOW LOW ESAS INITIATION SIGNAL COINCIDENT WITH A LOOP IS PRESENT. THIS IS PART OF THE LOAD MANAGEMENT SCHEME FOR EDC-1A. THE TRIP CAN BE DEFEATED IF EFP-2 IS UNAVAILABLE AND FEEDWATER IS REQUIRED. DEFEATING THE TRIP IS ACCOMPLISHED BY

3. PLACING THE CONTROL SWITCH TO DEFEAT IN ES ACTUATION CABINETS 1, 2, AND OPERATION OF ANY ONE SWITCH CAUSES ANNUNCIATION OF THIS ALARM.

OPERATION OF THE REMAINING SWITCHES CAUSE THIS ALARM REFLASH.

REFERENCES:

DRAWING 211-028 ES-A35 SENSING ELEMENT:

AR-403 Rev. 28 Page 145 V

l ENCLOSURE 1 (Page 144 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-04 H-06-04 EF PUMP 1 TRIP DEFEATED EVENT POINT 1181 INDICATED CONDITION:

EFP-1 TRIP DEFEAT CONTROL SWITCH IS IN " DEFEAT" POSITION i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

VISUAL OBSERVATION OF ONE TWO, OR THREE EFP-1 TRIP DEFEAT CONTROL SWITCHES IN DEFEAT POSITION. ES ACTUATION TEST CABINETS 1, 2, AND 3 EACH CONTAIN ONE CONTROL SWITCH.

OPERATOR ACTIONS FOR A VALID ALARM:

VERIFY THE REQUIREMENTS FOR PLACING CONTROL SWITCH TO " DEFEAT" ARE MET:

EFP-2 NOT AVAILABLE, FEEDWATER IS REQUIRED, A LOSS OF OFFSITE POWER EVENT IS IN PROGRESS AND LPI INITIATION IS IMMINENT OR HAS OCCURRED DISCUSSION:

ESAS GENERATES A TRIP SIGNAL TO EFP-1 WHEN AS RCS LOW LOW ESAS INITIATION SIGNAL COINCIDENT WITH A LOOP IS PRESENT. THIS IS PART OF THE LOAD MANAGEMENT SCHEME FOR EDC-1A. THE TRIP CAN BE DEFEATED IF EFP-2 IS UNAVAILABLE AND FEEDWATER IS REQUIRED. DEFEATING THE TRIP IS ACCOMPLISHED BY PLACING THE CONTROL SWITCH TO DEFEAT IN ES ACTUATION CASINETS 1, 2, AND 3.

OPERATION OF ANY ONE SWITCH CAUSES ANNUNCIATION OF THIS ALARM.

OPERATION OF THE REMAINING SWITCHES CAUSE THIS ALARM REFLASH.

f

REFERENCES:

DRAWING 211-028 ES-A36

{

SENSING ELEMENT:

AR-403 Rev. 28 Page 146 I

j ENCLOSURE 1 (Page 145 of 190)

-- =. _ ,..., --

PSA-Z ANWNCIATOR. RESPONSE PSA-Z-06-04 H-06-04 i

EF PUMP 1 TRIP DEFEATED 1

EVENT POINT 1301 INDICATED CONDITION:

l EFP-1 TRIP DEFEAT CONTROL SWITCH IS IN " DEFEAT" POSITION O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

VISUAL OBSERVATION OF ONE, h 0. OR THREE EFP-1 TRIP DEFEAT CONTROL SWITCHES IN DEFEAT POSITION. ES ACTUATION TEST CABINETS 1 2, AND 3 EACH CONTAIN ONE CONTROL SWITCH.

OPERATOR ACTIONS FOR A VALID ALARM:

VERIFY THE REQUIREMENTS FOR PLACING CONTROL SWITCH TO " DEFEAT" ARE MET:

EFP-2 NOT AVAILABLE, FEEDWATER IS REQUIRED, A LOSS OF OFFSITE POWER EVENT IS IN PROGRESS AND LPI INITIATION IS IMMINENT OR HAS OCCURED DISCUSSION:

ESAS GENERATES A TRIP SIGNAL TO EFP-1 WHEN AS RCS LOW LOW ESAS INITIATION SIGNAL COINCIDENT WITH A LOOP IS PRESENT. THIS IS PART OF THE LOAD MANAGEMENT SCHEME FOR EDG-1A. THE TRIP CAN BE DEFEATED IF EFP-2 IS UNAVAILABLE AND FEEDWATER IS REQUIRED. DEFEATING THE TRIP IS ACCOMPLISHED BY

3. PLACING THE CONTROL SWITCH TO DEFEAT IN ES ACTUATION CABINETS 1, 2. AND OPERATION OF ANY ONE WHICH CAUSES ANNUNCIATION OF THIS ALARM.

OPERATION OF THE REMAINING SWITCHES CAUSE THIS ALARM REFLASH.

REFERENCES:

DRAWING 211-028 ES-A37 SENSING ELEMENT:

AR-403 Rev. 28 Page 147

ENCLOSURE 1 (Page 146 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-06 H-06-06 I i

EFIC BYPASS EVENT POINT 2012 l INDICATED CONDITION:

o EFIC CHANNEL A IN MAINTENANCE BYPASS, o ANY EFIC CHANNEL A TEST SWITCH NOT IN NORMAL.

o ANY EFIC CHANNEL A CIRCUIT BREAKER OPEN,

'+ ' o ANY EFIC CHANNEL A MODULE WITHDRAWN.

o

EFIC CHANNEL A CABINET POWER SUPPLY FAILURE.

o EFIC CHANNEL A MAINTENANCE BYPASS ISOLATOR FAILURE.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE IS INDICATED BY MAINTENANC BYPASS ALARM WITHOUT THE LOCAL CHANNEL MAINTENANCE BYPASS LED FLASH

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28 Page 148

0 ENCLOSURE 1 (Page 147 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06-06 EFIC BYPASS EVENT POINT 2020 INDICATED CONDITION:

o EFIC CHANNEL B IN MINTENANCE BYPASS.

l o ANY EFIC CHANNEL B TEST SWITCH NOT IN NORMAL.

o ANY EFIC CHANNEL B CIRCUIT BREAKER OPEN.

o ANY EFIC CHANNEL B MODULE WITHDRAWN.

C*, o EFIC CHANNEL B CABINET POWER SUPPLY FAILURE.

o EFIC CHANNEL B MAINTENANCE BYPASS ISOLATOR FAILURE.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE IS INDICATED BY MAINTENANCE BYPASS ALARM WITHOUT THE LOCAL CHANNEL MAINTENANCE BYPASS LED FLASH

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 2 SENSING ELEMENT:

AR-403 Rev. 28 Page 149

ENCLOSURE 1 (Page 148 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-06 H-06-06 i

EFIC BYPASS EVENT POINT 2025 INDICATED CONDITION:

o EFIC CHANNEL C IN MAINTENANCE BYPASS.

o ANY EFIC CHANNEL C TEST SWITCH NOT IN NORMAL.

o ANY EFIC CHANNEL C CIRCUIT BREAKER OPEN.

O o ANY EFIC CHANNEL C MODULE WITHDRAWN.

o o

EFIC CHANNEL C CABINET POWER SUPPLY FAILURE.

EFIC CHANNEL C MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID AL %dM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE IS INDICATED BY MAINTENANC BYPASS ALARM WITHOUT THE LOCAL CHANNEL MAINTENANCE BYPASS LED FLASH O

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 3 SENSING ELEMENT:

AR-403 Rev. 28 Page 150 u.

[

ENCLOSURE-1 (Page 149 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06-06 EFIC BYPASS EVENT POINT 2029 INDICATED CONDITION:

o EFIC CHANNEL D IN MAINTENANCE BYPASS.

o ANY EFIC CHANNEL D TEST SWITCH NOT IN NORMAL.

o ANY EFIC CHANNEL D CIRCUIT BREAKER OPEN.

O o ANY EFIC CHANNEL D MODULE WITHDRAWN.

o EFIC CHANNEL D CABINET POWER SUPPLY FAILURE.

o EFIC CHANNEL D MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o MAINTENANCE BYPASS DIGITAL ISOLATOR FAILURE IS INDICATED BY MAINTENA BYPASS ALARM WITHOUT THE LOCAL CHANNEL MAINTENANCE BYPASS LED FLAS

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 4 SENSING ELEMENT:

AR-403 Rev. 28 Page 151

ENCLOSURE 1 (Page 150 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06-06 l

EFIC BYPASS EVENT POINT 2030 l

INDICATED CONDITION:

l o o EFIC "M.S. CHANNEL A EFW TEST SWITCH IN " TEST" POSITION.

ISOLATION VALVES AIR SUPPLY TEST A" SWITCH SELEGED TO NUMBER 2, "MSI SV-2 EFIC HALF / TRIP" OR NUMBER 1, "MS l. FW ISOLATION".

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o KEY OPERATED POSITION. TEST SWITCH IN RELAY RACK RR3A IS SELECTED TO THE " TEST" (CRD ROOM)

OPERATOR AGIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

o NOTIFY 5500 0F KEY SWITCH POSITION.

DISCUSSION:

o SELECTING THE " TEST" POSITION BLOCKS THE OUTPUT OF BUS 1 AND "A" EFW BUS 2.

REFERENCES:

DRAWING 208-032-FW-47, 208-026-EF-15 SENSING ELEMENT:

AR-403 Rev. 28 Page 152

ENCLOSUEE_1 (Page 151 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-06 H-06-06 l

EFIC BYPASS EVENT POINT 2031 INDICATED CONDITION:

o EFIC CHANNEL 8 EFW TEST SWITCH IN TEST POSITION.

o "M.S.

ISOLATION VALVES AIR SUPPLY TEST B" SWITCH SELECTED TO NUMBER 2, lO I

V "MSI SV-1 EFIC HALF TRIP" OR NUMBER 1, "MS & FW ISOLATION".

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o KEY OPERATED TEST SWITCH IN RELAY RACK RR581 IS SELECTED TO THE " TEST" POSITION. (EFIC ROOM B)

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

o NOTIFY 5500 0F KEY SWITCH POSITION.

DISCUSSION:

o SELECTING THE " TEST" POSITION BLOCKS THE MTPUT OF "B" EFW BUS 1 AND BUS 2.

[

REFERENCES:

DRAWING 208-032-FW-48, 208-026-EF-16 SENSING ELEMENT:

AR-403 Rev. 28 Page 153

ENCLOSURE 1 (Page 152 of 190) l PSA-Z-ANNUNCIATOR RESPONSE PSA-2 06-06 H-06-06 EFIC BYPASS EVENT POINT 2032 INDICATED CONDITION:

o EFIC AUXILIARY RELAY BOX 1C TEST SWITCH IN TEST, l'h b

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o AUTOMATIC REPOSITIONING OF EFV-11 AND EFV-32 BY EFIC IS BLOCKED WHEN IN TEST.

REFERENCES:

DRAWING 208-026-EF-21

'~

SENSING ELEMENT:

AR-403 Rev. 28 Page 154

t ENCLOSURE 1 (Page 153 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-06 H-06-06 EFIC BYPASS EVENT POINT 2033 INDICATED CONDITION:

o EFIC AUXILIARY RELAY BOX 1D TESY SWITCH IN TEST.

bJ l

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF ALARM CONDITION.

DISCUSSION:

o AUTOMATIC TEST. REPOSITIONING OF EFV-14 AND EFV-33 BY EFIC IS BLOCKED WHEN IN I

REFERENCES:

DRAWING 208-026-EF-22 SENSING ELEMENT:

AR-403 Rev. 28 Page 155

~

ENCLOSURE 1 (Page 154 of-190)

PSA-Z ANNUNCIATOR RESPONSE lPSA-Z-06-06 H-06-06 4

EFIC BYPASS EVENT POINT 2034 INDICATED CONDITION:

o EFIC ES-A BYPASS / TESTING.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

THIS EVENT POINT IS RECEIVED DURING EFIC TESTING BY PLACING THE SPRING RE10RN TO NORMAL SWITCH TO EITHER TEST 1 OR TEST 2 POSITION IN THE ES-A MANUAL ACTUATION CABINET 40.

THESE TEST POSITIONS SIMULATE AN ES "A" SIGNAL TO EFIC CHANNELS "A" OR "B". THIS SWITCH DOES NOT EYPASS ANY ACTUATION SIGNAL FROM ENGINEERED SAFEGUARDS.

REFERENCES:

DRAWING 208-028-ES-A65 SENSING ELEMENT:

AR-403 Rev. 28 Page 156

ENCLOSUAL1 (Page 155 of 190)

PSA-Z ANNUNCIATOR RESPONSE , PSA-2-06-06 H-06-06 EFIC BYPASS l

EVENT POINT 2035 INDICATED CONDITION:

o EFIC ES-B BYPASS / TESTING.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR - A VALID ALARM:

o INVESTIGATE CAUSE OF ALARM CONDITION.

DISCUSSION:

THIS EVENT POINT IS. RECEIVED DURING EFIC TESTING BY PLACING THE SPRING RETURN TO NORMAL SWITCH TO EITHER TEST 1 OR TEST 2 POSITION IN THE ES-B MANUAL ACTUATION CABINET 50. THESE TEST POSITIONS SIMULATE SIGNAL TO EFIC CHANNELS "A" OR "B".

"B" AN ES THIS SWITCH DOES NOT BYPASS ANY ACTUATION SIGNAL FROM ENGINEERED SAFEGUARDS.

REFERENCES:

DRAWING 208-028-ES-B65

\ SENSING ELEMENT:

AR-403 Rev. 28 Page 157

p

( ENCLOSURE 1 (Page 156 of 190)  ;

. PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-07 H-06-07 i

EFIC SHUTDOWN BYPASS EVENT POINT 2013 INDICATED CONDITION:

I o EFIC CHANNEL "A" MAIN STEAM ISOLATION ACTUATION BYPASSED.

/

v REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CHANNEL "A" ILLUMINATED. <725 PSI STM GEN PRESS EFIC ACT BYPASS' PUSH-BUTTON OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

THIS EVENT POINT IS RECEIVED WHEN PLANT CONDITIONS ALLOW THE BYPASSING OF MSLI/MWFI ACTUATION, AND THE BYPASS PUSH-BUTTON HAS BEEN DEPRESSED. THE AGUATION SETPOINT IS <600 PSIG AND THE BYPASS IS ALLOWED WHEN OTSG PRESSURES ARE APPROXIMATELY <725 PSIG.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 1 SENSING ELEMENT:

AR-403 Rev. 28 Page 158

ENCLOSURE 1 (Page 157 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-07 H-06-07

-=

EFIC SHUTDOWN BYPASS EVENT POINT 2021 INDICATED CONDITION:

o EFIC CHANNEL "B" MAIN STEAM ISOLATION ACTUATION BYPASSED.

1 (O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CHANNEL "B" ILLUMINATED.

<725 PSI STM CEN PRESS EFIC ACT BYPASS' PUSH-BUTTON OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

THIS EVENT POINT IS RECEIVED WHEN PLANT CONDITIONS ALLOW THE BYPASSING O MSLI/MWFI ACTUATION, AND Tile BYPASS PUSH-BUTTON HAS BEEN DEPRESSED. THE ACTUATION SETPOINT IS <600 PSIG AND THE BYPASS IS ALLOWED WHEN OTSG PRESSURES ARE APPROXIMATELY <725 PSIG.

[O <

Y

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 2

_ SENSING ELEMENT:

AR-403 Rev. 28 Page 159

MCLQ1EL.1 (Page 158 of 190)

PSA-Z ANNUNCIATOR RESMWSE PSA-2-06-07 H-06-07 EFIC SHUTDOWN i

BYPASS '

i EVENT POINT 2024 INDICATED CONDITION:

o EFIC CHANNEL "C" MAIN STEAM ISOLATION ACTUATION BYPASSED.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CHANNEL "C" <725 PSI STM GEN PRESS EFIC ACT BYPASS' PUSH-BUTTON ILLUMINATED.

OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

THIS EVENT POINT IS RECEIVED WHEN PLANT CONDITIONS ALLOW THE BYPASSI MSLI/MWFI ACTUATION AND THE BYPASS PUSH-BUTTON HAS BEEN DEPRESSED. T ACTUATION SETPOINT IS <600 PSIG AND THE BYPASS IS ALLOWED WHEN OTSG PRESSURES ARE APPROXIMATELY <725 PSIG.

REFERENCES:

VITRO DRAWING 3801-3005 SHEET 3 SENSING ELEMENT:

AR-403 Rev. 28 Page 160 l\ '

2 ENCLOSURE 1 (Page 159 of 190) i PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-07 H-06-07 EFlO

, SHUTDOWN BYPASS EVENT POINT 2028 INDICATED CONDITION:

o EFIC CHANNEL "D" MAIN STEAM ISOLATION ACTUATION BYPASSED.

O REDUNDANT INDICATION WHICH WILL VERI W ALARM:

o CHANNEL "D"

<725 PSI STM GEN PRESS EFIC ACT BYPASS' PUSH-801 TON ILLUMINATED.

OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

THIS EVENT POINT IS RECEIVED WHEN PLANT CONDITIONS ALLOW THE BYPASSING OF MSLI/MWFI ACTUATION, AND THE BYPASS PUSH-BUTTON HAS BEEN DEPRESSED. THE ,

ACTUATION SETPOINT IS <600 PSIG AND THE BYPASS IS ALLOWED WHEN OTSG PRESSURES ARE APPROXIMATELY <725 PSIG.

REFERENCES:

VITRO ORAWING 3801-3005 SHEET 4 SENSING ELEMENT:

AR-403 Rev. 28 Page 161

l l

O ENCLOSURE 1 (Page 160 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-08 H-06-08 EFIC AH SYSTEM TROUBLE EVENT POINT 0767 INDICATED CONDITION:

o AHF-54A/AHF-548 DUCT, SMOKE DETECTED, OR TROUBLE AS SENSED BY PYROTRONIC SMOKE DETECTION MODULES AH-934-CE1 OR AH-934-CE2.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF SMOKE DETECTED OR TROUBLE ALARM.

DISCUSSION:

REFERENCES:

DRAWING 208-005-AH-185 SENSING ELEMENT: AH-934-CE1, AH-934-CE2 AR-403 Re,*. 28 Page 162

ENCLOSURE 1 (Page 161 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z 06-08 H-06-08 EFlO AH SYSTEM TROUBLE EVENT POINT 0768 INDICATED CONDITION:

o AHF-51A/AHF-54B DUCT TEMPERATURE >85* AS SENSED BY AH-932-TS1/TS2.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM OPERATOR ACTIONS i:0R A VALID ALARM:

o INVESTICATE CAUSE OF DUCT llIGH TEMPERATURE ALARM.

DISCUSSION:

REFERENCES:

DRAWING 208-005-AH-185 SENSING ELEMENT: AH-932-TS1, AH-932-TS2 AR-403 Rev. 28 Page 163

ENCLOSURE 1 (Page 162 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-06-08 H-06-08 EFic AH SYSTEM TROUBLE EVENT POINT 0774 INDICATED CONDITION:

o AHF-$4A/AHF-54B DUCT, FLOW LOW AS SENSED BY AM-933-FS1/FS2.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF LOW AIRFLOW ALARM.

DISCUSSION:

THIS ALARM POINT IS ACTUATED WHEN EFIC DUCT AIRFLOW IS LESS THAN 70%

OF DESIGN AIRFLOW.

REFERENCES:

DRAWING 208-005-AH-185 SENSING ELEMENT: AH-933-FS1, AH-933-FS2 AR-403 Rev. 28 Page 164 -

riribsi;;tt 1 '

(? age 163 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-06-08 H-06-08 EFIC AH SYSTEM TROUBLE EVENT POINT 0775 INDICATED CONDITION:

o EFIC ROOM (S) TEMPERATURE HIGH/ LOW AS SENSED BY AH-944-TS1/TS2/TS3/TS4.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF EFIC ROOM TEMPERATURE ALARM.

DISCUSSION:

THIS ALARM POINT IS ACTUATED WHEN ANY EFIC ROOM TEMPERATURE IS LESS THAN 60*F OR CREATER THAN 85'F. ONE DETECTOR IS LOCATED IN EACH EFIC ROOM MOUNTED ON THE WALL APPROXIMATELY 4' FROM THE FLOOR. IF ALARM IS IN FOR NO APPARENT REASON ENGINEERING CAN ADJUST DAMPER AND/OR DUCT REGISTER POSITIONS TO BETTER DISTRIBUTE AIR FLOW THROUGHOUT THE ROOMS.

REFERENCES:

DRAWING 208-005-AH-185 SENSING ELEMENT: AH-944-TS1, AH-944-TS2, AH-944-TS3, AH-944-TS4 AR-403 Rev. 28 Page 165

O ENCLOSURE 1 (Page 164 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-01 H-07-01 l l EF TANK l l LEVEL l l LOW LOW I I I I EVENT POINT 0815 INDICATED CONDITION:

o EFT-2 LEVEL <8'O' AS SENSED BY EF-98-LT.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EF-98-LII, EMERCENCY FEED TANK LEVEL INDICATION.

o EF-99-LI1, EMERGENCY FEED TANK LEVEL INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

DISCUSSION:

THE LOW-LOW LEVEL ALARM SETPOINT IS EQUIVALEffi TO 30.600 CALLONS.

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

REFERENCES:

DRAWING 205-026-EF-05 SENSING ELEMENT: EF-98-LT AR-403 Rev. 28 Page 166

ENCLDIURE_1

) (Page 165 of 190) l PSA-Z ANNUNCIATOR RESPONSE PSA-2-07-02 H-07-02 l

)

EF PUMP 1 AUTO STAMT EVENT POINT 1681 INDICATED CONDITION:

o EFP-1 MOTOR ENERGIZED WITH CONIROL Sh!TCH IN NORMAL AFTER STOP POSITION. 1 O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT ON WITH A CREEN FLAG ON EFP-1 CONTROL STATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

DISCUSSION:

REFERENCES:

DRAWING 208-026-EF-01B SENSING ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/ST, CS/0 AR-403 Rev. 28 Page 167

l ENCLOSURE 1 (Page 166 of 190)

P3A-Z ANNUNCIATOR RESPONSE PSA-Z-07-03 H-07-03 EF PUMP 1 START FAILURE EVENT POINT 1680 INDICATED CONDITION:

o EFP-1 MOTOR NOT ENERGIZED WITH CONTROL SWITCH IN NORMAL AFTER STOP POSITION. AND 50 SECONDS HAVE ELAPSED WITH AN ACTUATION SIGNAL PRESENT.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

o MANUALLY START EFP-1 DISCUSSION:

IF EFP-1 FAILED TO START FROM A VALID AGUATION SIGNAL BUT WAS MANUALLY STARTED THEN THIS ALARM WILL NOT ACTUATE DUE TO THE 50 SECOND TIME DELAY RELAY CIRCUIT. THE CONTROL SWITtH MUST BE IN THE NORMAL AFTER STOP POSITION TO ACTUATE THIS ALARM.

REFERENCES:

DRAWING 208-026-EF-01B SENSING ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/ST, CS/0 AR-403 Rev. 28 Page 168

ENCLOSURE 1 (Page 167 of 190)

PSA-Z ANNUNCIATOR RESPONSE H-07-03

PSA-2-.07-03 EF PUMP 1 START FAILURE I EVENT POINT 1682 INDICATED CONDITION

o EFP-1 DISCHARGE PRESSURE <1100 PSIC AS SENSED BY EF-17-PS WITH CONTROL SWITCH IN NORMAL AFTER START POSITION.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO EOP.

o INVESTIGATE CAUSE OF LOW DISCIIARGE PRESSURE.

DISCUSSION:

THEEVENT THIS CONTROL POINT. SWITCH MUST BE IN THE NORMAL AFTEr START POSITION TO ACTUATE

REFERENCES:

DRAWING 208-026-EF-01B SENSING ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/SC, CS/0, EF-17-PS AR-403 Rev. 28 Page 169

4 4

O LNCLOSURE 1 (Page 168 of 190) ,

i PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-04 H-07-04 ll e

EF PUMP 1 TRIP 4

1 EVENT POINT 1261

INDICATED CONDITION

o EFP-1 MOTOR NOT ENERGIZED WITH CONTROL SWITCH IN NORMAL AFTER START POSITION.

O

{ REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON W::TH A RED FLAG ON EFP-1 CONTROL STATION.

l i

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

o INVESTICATE CAUSE OF BREAKER TRIP.

DISCUSSION:

THE CONTROL SWITCH MUST BE IN THE NORMAL AFTER START POSITION TO ACTUATE THIS EVENT POINT.

1

REFERENCES:

DRAWING 208-026-EF-01 SENSING ELEMENT: EFP-1 CONTROL SWITCH CONTACTS CS/SC, CS/0 AR-403 Rev. 28 Page 170 l

l l

l ENCLOSURE 1 (Page 169 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-07-05 H-07-05 EF PUMP 1 OUT OF SERVICE EVENT POINT 1191 INDICATED CONDITION:

I o EFP-1 CONTROL SWITCH IN PULL TO LOCK POSITION O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN AND RED LIGHTS EXTINGUISHED ON CONTROL STATION.

OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

REFERENCES:

DRAWING 208-026-EF-01 SENSING ELEMENT:

EFP-1 CONTROL SWITCH CONTACTS CS/PTL AR-403 Rev. 28 Page 171

ENCLOSURE 1 (Page 170 of 190)

PSA-Z AisNUNCIATOR RESPONSE PSA-Z-07-05 H-07-05 l

EF PUMP 1 OUT OF SERVICE i

EVENT POINT 1257 INDICATED Gr4DITION:

o EFP-1 CIRCUIT BREAKER NOT RACKED IN.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN AND RED LIGHTS EXTINGUISHED ON CONTROL STATION.

OPERATOR AGIONS FOR A VALID ALARM:

DISCUSSION:

REFERENCES:

DRAWING 208-026-EF-01 SENSING ELEMENT: EFP-1 BREAKER 52H/B CONTAGS

-AR-403 Rev. 28 Page 172

l ENCLOSURE 1 (Page 171 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-05 H-07-05 1

EF PUMP 1 OUT OF SERVICE EVENT POINT 1259 INDICATED CONDITION:

o EFP-1 CIRCUIT BREAKER LOSS OF DC CONTROL POWER.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM o CREEN AND RED LIGHTS EXTINGUISHED ON CONTROL STATION.

OPERATOR ACTIONS FOR A VALID ALARM:

DISCUSSION:

REFERENCES:

-DRAWING 208-026-EF-01 SENSING ELEMENT:

EFP-1 BREAKER CONTROL CIRCUIT 27 RELAY AR-403 Rev. 28 Page 173

_ _ _ _ _ _ . . . . _ m. _. -_ _ _ _ _ _ _ . _ _ _ . _ _ . _ _ _ _ _ . _ . _ _ _ _ _ _ -

O ENCLOSURE 1 (Page 172 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-07-06 H-07-06 i

EF PUMP 1 MOTOR OVERLOAD 4

EVENT POINT 1260 INDICAYED CONDITION:

o EFP-1 MOTOR AMPS >115% RATED LOAD.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH MOTOR AMPS.

o EFP-1 BREAKER TRIP.

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

o START EFP-2.

o REDUCE EMERCENCY FEEDWATER FLOW FROM EFP-1 IF STILL RUNNING.

DISCUSSION:

THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.

IT IS PO5SIBLE TO HAVE THIS ALARM PRIOR TO THE BREAKER TRIP.

REFERENCES:

DRAWING 208-026-EF-01 SENSING ELEMENT: EFP-1 BREAKER 51 RELAY (INSIDE 4160 BREAKER CUBICLE)

AR-403 Rev. 28 Page 174

ENCLOSURE 1 (Page 173 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-07 H-07-07 l

FWP7 TRIP EVENT POINT 0819 INDICATED CONDITION:

o FWP-7 MOTOR POSITION. NOT ENERGIZED WITH CONTROL STATION IN NORMAL AFTER START O

REDUNDANT INDICATION h...CH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON FWP-7 CONTROL STATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF BREAKER TRIP.

DISCUSSION:

REFERENCES:

DRAWING 208-032 FW-55 SENSING ELEMENT: CS/SC. CS/0 AR-4(3 Rev. 28 Page 175

t i

ENCLOSURE 1 (Page 174 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-07-08 H-07-08 l

l FWP7 OVERCURRENT l ______ -

EVENT POINT 0780 INDICATEDCONDT5[0N:

o FWP-7 MOTOR AMPS >115% RATED LOAD v

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH MOTOR AMPS o FWP-7 BREAKER TRIP OPERATOR ACTIONS FOR A VALID ALARM:

o REDUCE FEEDWATER FLOW FROM FWP-7 IF STILL RUNNING DISCUSSION:

THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.

IT IS POSSIBLE TO HAVE THIS ALARM PRIOR TO THE BREAKER TRIP.

REFERENCES:

DRAWING 208-032 FW-55 SENSING ELEMENT:

O FWP-7 BREAKER 51 RELAY (INSIDE 4160 BREAKER CUBICLE)

AR-403 Rev. 28 Page 176

!i ENCLOSURE _1

} (Page 175 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-01 H-08-01 i

j l l EF TANK l g LEVEL l l HIGH/ LOW 2

I P

, l i

~

EVENT POINT 0816 INDICATED CONDITION:

I o EFT-2 LEVEL >37'0' AS 1ENSED BY EF-98-LT.

3 i

!O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EF-98-LIl EMERCENCY FEED TANK LEVEL INDICATION.

o EF-99-LIl EMERGENCY FEED TANK LEVEL INDICATION.

i OPERATOR ACTIONS FOR A VALID ALARM:

L o RESTORE TANK LEVEL TO NORMAL OPERATING BAND.

4

DISCUSSION

THE HIGH LEVEL ALARM SETPOINT IS EQUIVALENT TO 163,900 CALLONS.

M

REFERENCES:

DRAWING 205-026 EF-05 SENSING ELEMENT: EF-98-LT AR-403 Rev. 28 Page 177

ENCLOSURE 1 (Page 176 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-01 H-08-01 )

l l l EF TANK LEVEL l HIGH/ LOW I I I I EVENT POINT 0817 INDICATED CONDITION:

o EFT-2 LEVEL <34'6' AS SENSED BY EF-99-LT.

,O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EF-98-LIl EMERGENCY FEED TANK LEVEL INDICATION.

o EF-99-LII EMERGENCY FEED TANK LEVEL INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o RESTORE TANK LEVEL TO NORMAL OPERATING BAND.

DISCUSSION:

THE LOW LEVEL ALARM SETPOINT IS EQUIVALENT TO 152.500 GALLONS.

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

REFERENCES:

DRAWING 205-026 EF-05 SENSING ELEMENT: EF-99-LT AR-403 Rev. 28 Page 178 i

' ENCLOSURE 1 (Page 177 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-02 H-08-02

, I 1

EF PUMP 2

__ -- AUTO START EVENT POINT 1707 INDICATED CONDITION:

o EFP-2 DISCHARGE PRESSURE >IIDO PSIG AS SENSED BY EF-18-PS. AND 50 SECONDS HAVE ELAPSED WITH AN ACTUATION SIGNAL PRESENT.

O V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

DISCJLSION;

REFERENCES:

DRAWING 208-008 AS-01 SENSING ELEMENT: EF-18-PS AR-403 Rev. 28 Page 179 i

m

ENCLOSURE 1 (Page 178 of 190)

PSA-Z ANNUNCIATC cPONSE PSA-Z-08-03 H-08-03 EF PUMP 2 START FAILURE EVENT POINT 1706 INDICATED CONDITION:

o EFP-2 DISCHARGE PRESSURE <1100 PSIG AS SENSED BY EF-18-PS, CD 50 SECONDS HAVE ELAPSED WITH AN ACTUATION SIGNAL PRESENT.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO E0P.

DISCUSSION:

t O

,V

REFERENCES:

DRAWING 208-008 AS-01 SENSING ELEMENT: EF-18-PS AR-403 Rev. 28 Page 180

ENCLOSEE_1 (Page 179 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-04 H-08-04 i

l EF PUMP 2 TRIP 1

EVENT POINT 0326 l

INDICATED CONDITION:

o TURBINE OPEN. DRIVEN EMERCENCY FEEDWATER PUMP STEAM SUPPLY VALVE ASV-50 NOT REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY PRIMARY PLANT OPERATOR TO RESET ASV-50 DISCUSSION:

REFERENCES:

DRAWING 208-008 AS-01 SENSING ELEMENT: 33C/ASV-50 AR-403 Rev. 28 Page 181

ENCLOSURE 1 (Page 180 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-05 H-08-05 EF PUMP 2 OUT OF SERVICE I

a EVENT POINT 0100 INDICATED CONDITION:

o ASV-5 CLOSED, WITH DC CONTROL POWER NOT AVAILABLE FOR >5 SECONDS.

o MSV-55 CLOSED.

o MSV-56 CLOSED.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o ASV-5 POSITION INDICATION.

o MSV-55 POSITION INDICATION.

o MSV-56 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE LOSS OF CONTROL POWER TO ASV-5.

o INVESTICATE CLOSURE OF MSV-55 OR MSV-56.

DISCUSSION:

IF THIS ALARM IS DUE TO THE ASV-5 CIRCUITRY THEN IT MEANS ASV-5 IS CLOSED WITH NO CONTROL POWER AVAILABLE TO ALLOW AN AUTO OPEN DURING AN EFW ACTUATION.

THE MSV-55 AND MSV-56 ALARMS ARE DUE TO FULLY CLOSED LIMIT SWITCHES.

CONTROL POWER FOR ASV-5 IS SUPPLIED FROM DPDP-88 FUSE #6.

O

REFERENCES:

DRAWING 208-008 AS-01 SENSING ELEMENT: ASV-5 LS(13), 2ASV-5 RELAY, MSV-55 LS(5), MSV-56 LS(14)

AR-403 Rev. 28 Page 182

'O ENCLOSURE 1 (Page 181 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-05 H-08-05 l

l l

EF PUMP 2 OUT OF SERVICE EVENT POINT 1521 INDICATED CONDITION:

o ASV-204 CLOSED. WITH DC CONTROL POWER NOT AVAILABLE.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o ASV-204 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE LOSS OF CONTROL POWER TO ASV-204.

DISCUSSION:

THIS ALARM MEANS ASV-204 IS CLOSED WITH NO CONTROL POWER AVAILABLE TO ALLOW AN AUTO OPEN DURING AN ACTUATION. CONTROL POWER FOR ASV-204 IS SUPPLIED FROM DPDP-8A FUSE #15.

REFERENCES:

DRAWING 208-0CS AS-07 SENSING ELEMENT: ASV-204 LS(13), 27ASV-204 RELAY AR-403 Rev. 28 Page 183

i O ENCLOSURE 1 (Page 182 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-06 H-08-06 EMERG FW VALVE NOT FULL OPEN EVENT POINT 1192 INDICATED CONDITION:

o EFV-32 NOT FULL OPEN.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-32 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CLOSURE OF EFV-32.

DISCUSSION:

REFERENCES:

DRAWING 208-026 EF-10 SENSING ELEMENT: EFV-32 FULL OPEN LIMIT SWITCH

~AR-403 Rev. 28 Page 184

EfiCLOSURE 1

\ (Page 183 of 190)

PSA-Z ANNUNCIATOR RESPONSE psA.Z-08-06 H-08-06 l

EMERG FW VALVE NOT FULL OPEN l ,

EVENT POINT 1193 INDICATED CONDITION:

o EFV-11 NOT FULL OPEN.

i O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-11 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CLOSURE OF EFV-11.

DISCUSSION:

REFERENCES:

DRAWING 208-026 EF-08 SENSING ELEMENT: EFV-11 FULL OPEN LIMIT SWITCH AR-403 Rev. 28 Page 185

l ENCLOSURE 1 (Page 184 of 190)

PSA-Z ANNUNCIATOR RESPONSE P ,-08-06 H-08-06 EMERG FW VALVE NOT FULL OPEN EVENT POINT 1194 INDICATED CONDITIOd:

o EFV-14 NOT FULL OPEN.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-14 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CLOSURE OF EFV-14.

DISCUSSION:

.fERENCES: DRAWING 208-026 EF-9 SENSING ELEMENT: EFV-14 FULL OPEN LIMIT-SWITCH AR-403 Rev. 28 Page 186

l

,O ENCLOSURE 1 (Page 185 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-06 H-08-06 EMERG FW VALVE

NOT FULL OPEN

~

a EVENT POINT 1196 l INDICATED CONDITION:

o EFV-33 NOT FULL OPEN.

O i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-33 POSITION INDICATION.

OPERATOR ACTIONS COR A 'iALID ALARM:

o INVESTICATE CLOSURE OF EFV-33.

DISCUSSION:

i' O

o

REFERENCES:

DRAWING 208-026 EF-11 SENSING ELEMENT: EFV-33 FULL OPEN LIMIT SWITCH

,.u-40s Rev. 28 Page 187

ENCLOSURE 1 (Page 186 of_190)

PSA-Z ANNUNCIATOR RESPONSE PSA-2-08-06 H-08-06

.~

l l

FMERG FW l

VALVE NOT FULL OPEN EVENT POINT 1255 INDICATED CONDITION:

l o EFV-3 NOT FULL OPEN.

O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-3 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CLOSURE OF EFV-3.

DISCUSSION:

REFERENCES:

DRAWING 208-026 EF-02 SENSING ELEMENT: EFV-3 FULL OPEN LIMIT SWITCH AR-403 Rev. 28 Page 188 d

[ ENCLOSURE 1 (Page 187 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08-06 I

EMERG FW VALVE NOT FULL OPEN i

EVENT POINT 1256 INDICATED CONDITION:

o EFV-4 NOT FULL OPEN.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-4 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CLOSURE OF EFV-4.

REFERENCES:

(

DRAWING 208-026 EF-03 SENSING ELEMENT: EFV-4 FULL OPEN LIMIT SWITCH AR-403 Rev. 28 Page 189

ENCLOSURE 1

( (Page 188 of 190)

PSA-Z ANNUNCIATOR RESPONSE

, PSA-2-08-06 H-08-06 EMERG FW

! VALVE NOT FULL OPEN l

EVENT POINT 1262 INDICATED CONDITION:

o EFV-7 NOT FULL OPEN.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-7 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CLOSURE OF EFV-7.

DISCUSSION:

REFERENCES:

DRAWING 208-026 EF-04 SENSING ELEMENT: EFV-7 FULL OPEN LIMIT SWITCH AR-403 Rev. 28 Page 190

\- -

?

O

,%J ENCLOSURE 1 (Page 189 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-06 H-08-06 EMERG FW VALVE NO T FULL OPEN EVENT POINT 1263 INDICATED CONDITION:

o EFV-8 NOT FULL OPEN.

O V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EFV-8 POSITION INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATC CLOSURE OF EFV-8.

DISCUSSION:

REFERENCES:

DRAWING 208-026 EF-05 SENSING ELEMENT: EFV-8 FULL OFEN LIMIT SWITCH AR-403 Rev. 28 Page 191 l

J

ENCLOSURE 1 (Page 190 of 190)

PSA-Z ANNUNCIATOR RESPONSE PSA-Z-08-07 H-08-07 EFV 12 EF CROSS-TIE OPEN l EVENT POINT 1266 INDICATED CONDITION:

l o EFV-12 OPEN.

O (V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT LIT ON EFV-12 CONTROL STATION, EFV-12-MST IN "A" ES 480v SWITCHGEAR ROOM, 124" ELEV CC.

o FLOW INDICATED ON EF-62-FI, LOCATED ON PSA SECTION OF MCB (TO BE INSTALLED BY MAR 97-01-04-01 OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY CROSS-FLOW VIA "A" SIDE EFIC FLOW INDICATORS.

DISCUSSION:

EFV-12 POWERED FROM DPDP-8C, BKRS 5 (POWER) & 6 (CONTROL)

REFERENCES:

DRAWING 208-026 EF-24 i SENSING ELEMENT: LIMIT SWITCH CONTACT #9 AR-403 Rev. 28 Page 192 (LAST PAGE) h o