Text
_ - -
/,r.
d II IN November 22, 1974 i
Harold D. Thornburg. Chief. Field support and Enforcement Branch Directorate of ReEulatory Operations, tiendquarters KT.RR-;!cGEE UUCLEA", C0!;po' 104 temAnnott FACILITY)
DOCKET No.70-925 A:
. o.1193 IIGPECTIO11 VIOLATION N t
In respouse to a telephona requast on Bovenber 21, 1974, by 5.am Bryan,
~
the attaejusant represents a chronology of violation h!.ntory resulting fro::t criticality, health physics, material control, and physical security inspections of Kerr-HcGee's uranium and plutonium facilities.
The Kerr-HeGoa physical security plan has been effectively implemented.
Initini inspection of the new plan in May,1974 identified several violations, but a subs'equent followup inspection in Septostor,1974 indicated reopensive corrective action. In general, Korr-HeGee has been recponsive to correcting violations associated with untorial control requirencats. Ou occasion, the Kerr-}!cGeo impiccentation of the ncv,
(
changing material control requirements, particularly the ones pertaining I
to the statistical and measurenant prograe.s, have been less ehty.
During recent nonths, Korr-;teGee's major portion of safeguards effort in this area has been directed to the Pu facility as cargared to the low enriched uraniun facility.
There have been ntsuerous criticality safety violations in the past two years, indicative of a lack of effectivo manst.e:nant control.
There has been an inprovemont in this area in the past year, but the inattention of Kerr-P.ccoe canager.:nt to so:::c license' coac:itments and theso violations have reduced to some degree the esfety factor of the criticality safety program.
Kerr-!!cCoe has, in general, been respcasive to correcting items of noncoepliance identified as a result of routine and special besith l
physics inspections. The Plutonissa aca Urantun Plant health physica l
staffs have been found to be capabla and staffed with qualified l
supervisory parsonnel. Corporate management safety personnal on occanions have been slas in responding to natters neoding prompt attention. A neating with Kerr-ticGee corporate management was held 8610290254 861023 gj ff /(ly.,
- 2.<p.f[
$iR
-281 PDR RO:III RO:III RO:III RO:II::
' F F 6C. >
a.
' ~ ~ -
R ay/dec_..W
< Alla Kep W 11/22/74 11/22//74 11/2M74 11/22/74
- v. 61.
wn.
,n -.m hp pyera.,dereh.s~/;,, MJ -
+
R. D. Thornburs
. November 22, 1974 l
.I on November 2.1973, by the P.egicnal Director and staff to discuss this and other matters of concern. A recent example of slow response occurred when the medical consultant did not arrive in Oklahoms City until November 9, two days after T.aren silkwood's fecal and urine sarples i
were found to be highly cont efanted. Plant health physics procedures, 3
equipment, and facilitias have been found to be satisfactory.
i 7-i Jack A. Hind, chief Hsterials and Plant' Protection Branch
~
Attschnent:
- 2/ 8' As stated ect Sam Bryan, R0tP.Q
~~
DR Central Files RO Filce g
l I
e
()n N $h$$
~
\\
)
h un>
Fes.n E518 (Rev.9 55) AECM 0340 gg,,,..,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
I.
I I
1
Material Control and Physical Protection (Pu)_
1/17-21/72 Dates of Icspection:
50-11-87 (Material Control and Security - Pu and U Plants)
Report No.
m Description of Violations:
~
No independent internal review. (U and Pu) (L.C.8.1).
1.
LE's not included on shipping documents ( and Pu) (70.54).
.r-2.
Receiptforms not comple*ted 'and distributed within required 3.
time (U' an4. Pu) (70.54).
4.
Enriched U'(grea r than 10% U-235) noti in separate fenced
.> s 1
krea outside (U (73.32(c)).
C
' 5.-
Security test of equipnient recoids not maintained (U and Pu)
C (73.41(b)).
Dates of Inspection:
1/14-16/73 2
Report No.: 070-1193/73-01 (Physical Protection)
Violations:
~
Permanent structure within 20 ft. of inside of fence (L.C.9.4.1).
1.
Perimeter fence not inspected during work hours (L.C.9.4.3).
2.
3.
Fu storage vault not protected by steel door or intrusion alarm (L.C.9.4.5 and 73.3(k)).
4.
' Intrusion alarms not being tested as required (L.C.9.4.8).
h.
Dates of Inspection: 2/21-23 and 3/12-16/73 lleport No.: 070-1193/73-03 (Material control)
Violations:
l 1.
Heasurement review not complete (L.C.3.4).
l 2.
Not closed a 30-day material balance (L.C.6.5).
3.
MBA and plant records not reconciled (L.C.7.1).
4.
Not in full compliance with independent audit requirements (L.C.8.1).
Dates of Inspection: 12/3-7/73 Report No.: 070-1193/73-08 (Material Control)
Violations:
,' i.
LDtUF for five material balance periods exceed speci'fication of 1.5 Kgs. Pu (L.C.3.2).
Dates of Inspection: 2/26-37/74 Report No.: 070-1193/74-03 (Material Control)
Violations: None t
$6
.J n -...
d Material Control and Physical Protection (Pu)
Dates of Inspection:
3/11-13/74 Report No.: 070-1193/74-02 (Physical Protection)
. Violations:
Combination lock on vault broken (73.3(j) and 73.3(e)).
1.
Visitors log information* not' complete (L.C.9.3.7 and 9.3.8).
2.
1
- 5~
Program Weakness:
Spurious Pu monitor alarms at dock area.
.e y
i Dates of Inspection:
5/6-9/74 Report No.: 070-1193/74-04 (Physical Protection)
Violations:
Failed to relocate TV camera at dock area (73.60(a)(7)).
1.
2.
Not conducting communications check with LLEA; should be each shif t rather than daily (Plan 10.4).
3.
Levels of illumination not as required on all sections of physical
-l barrier (Plan 2.1.2.2).
4.
Sample window not alarm'ed (L.C.9.3.2).
5.
Metal detector for exit search not installed (L.C.9.3.4).
8 6.
Installation of motion detector in vault not complete (L.C.9.3.5).
Protective personnel were not armed or uniformed (73.50(a)(1)).
7.
Door between(exhaut air fan room and supply air fan room}not 8.
alarmed (L.C.9.5).
j All required porta:4 not install d vit magnetic switch intrusion 9.
~
. g alarus rather than1 plunger typea (L.C.9. ).
Metal detector at entrance search installed but not operable d,
and electric door lock not installed (L.C.9.16.1 and 9.16.2 and
-12.
Intrusion alarms not installed n[ storage)areasinhabricatio)'
9.18.2).
area and in the asdembly jates (L.C.9.17.2).
Onlyonearmedg(inspection}an I
uard assighed each shift rather than the 13.
required two and an armed shift supervisor (L.C.9.18.3).
- 14. All existing intrusion alarms did not meet Federal specifications (L.C.9.18.4).
- 15. Log of individuals granted access to a normally unoccupied vital areas not being maintained (73.70(d)).
Dates of Inspection:
7/23-25/74 Report No.: 070-1193/74-06 (Material control)
Violations:
On three occasions. hen delayed measurements were made, the 741
[
w was not completed within 30-day period (70.54).
1
\\..
& COM be TGfe& m fo&
}-
Material Control and Physical Proteerion (Pu)
Dates of I'nspection: 8/21-23/74 Report No.:
070-1193/74-07 (Haterial Control)
Violations:
.=
1.
Accounting data for biases which exceed 10% of their standard deviations (L.C.3.5).
2.
Tamper-safing seals not being used (L.C.6.3).
3.
All SKM on. inventory not based on measurements (L.C.6.4.2).
. g-4.
Frequency of measurement of standards not being adhered to (L.C.3.3.2).
Date of Inspection: 9/11/74 Report No.:
070-1193/74-08 (Physical Security)
Violations:
Explosive detector not completely operable because ofsgur ousd 1.
alarms due to other types of material, i.e., perfume, smoke d
. (73.50(f)(1)).
~
Ofthe12intrbsionalarmstob'econvertedfrom[ plunge type)-
2.
tofmagnetic switch types, all had been converte& except one (L'.t. 9. 7).
%;s pfe cu Le rehsel in % fat
~
l 3
.i c
s
l and Physical Protection (U)[
Material Contro Dates of Inspection:
4/21-23 and 4/28-5/2/69 Report No.: S0-11-18 (Material Control)
Violations: Nona Dates of Inspection: 1/7-15/70 Report No.: S0-II-33 (Material Control)
Violations:
[6s on measurement system and on receipts, shipments, discards and
~
- HUF have not been established (not 3.0 and subparts).
Dates of Inspection: 10/5-9/70 l Report'No.: 50-II-56 (Material Control and Physical Protection)
Violations:
No manual continuing current procedures (L.C.1.2).
1.
No LE program on measurement system and on receipts, shipments, 2.
dis, cards and MUF (L.C.3.0).
Not accounted for all internal transfer documents nor documented 3.
all internal transfers (L.C.S.2).
Stored material outside in an area not separately fenced (73.32(c 4.
No records designating' authorized individuals (73.41(a)).
5.
o e
8 T
m 4
8 e
e ce bi%.b o
eis u m u s u m u u u s e i
I
.i
........y
_ Material Control and Physical Protection (U)_
Dates of Inspection: 1/16-18/73 070-925/73-01 (Physical Protection)
Report Fo.:
Violations: None Dates of Inspection:
2/21-23 and 3/12-16/73 070-925/73-03 (Haterial Control)
Report No.:
Violations:
7.
No independent percent element measurement of UF-6 receipts 1.
e (L.C.3.1).
~
Measurement review not complete (L.C.3.3).
2.
Not all 741's on receipts being dispatched on time (70.54).
~
3.
' Dates of Inspection:
11/13-16/73
~
070-925/73-07 (Material Control)
Report No.:
Violations:
No independent percent element measurement of UF-6 receipts 1.
(L.C.3.1).
I Not all 741's on receipts dispatched on time (70.54).
2.
Dates of Inspection:
11/25-27/74 i
Report No.:
070-925/74-02 (material Control)
. Violations:
t No material control plan submitted to Licensing (70.51(g)).
1.
Measurement review not complete (L.C.3.3).
2.
Dates of Inspection: 9/22-26/74 Report No.:
070-925/74-04 (Material Control)
Violations:
Standards data not being accumulated (L.C.3.2.3).
1.
Frequency of replicate sampling of process materials not 2.
complete (L.C.3.2.2).
All biases not being determined (L.C.3.3) 3.
Material accounting 0.ata not adjusted for biases (L.C.3.4).
4.
LE's do not include systematic errors (L.C.3.8).
5.
e be releas-d a loki TMi pye on
~2-i w-e e
J' i
l l
t
CRITICALITY AND BEALTH PHYSICS URANIUM INSPECTION AT KERR-McCEE f
Dates of Inspection Report No.
Description of Violations J
12/14-15/65 Memo,12/21/65 Pre-License, no violations.
5/10-12/66 Memo,5/19/66
.No violations.
9/13-14/66g-Ler,9/30/66 1.
Ref: 10 CFR 20.201(b).
Inadequate to K-M surveys to determitte compliance with
~
10 CFR 20.106(a), " Concentrations in
~
affluents to unrestricted areas."
2.
Ref: 10 CFR 20.201(b). Evaluations C
.~
of concentrations of licensed materia in restricted areas are inadequate ti show compliance vi~th 10 CFR 20.103(a'.
" Exposure of individuals to concentra of radioactive material in restricte.
... ~
areas."
.2/1-2/67 Memo,2/10/67 No violations.
7/5-6/67 Memo,6/11/67 No violations.
11/2-3/67 Memo,11/30/67 No violations.
2/6-8/68 Ltr. 2/19/68 1.
Ref: License Condition No. 12. Fai to K-M to require employees handling materi to shower at the end of a work shift i
2.
Reft License Condition No.'12.
Smoking in the plant is not restrict to approved areas, nor, are approved areas delineated.
5/22-23/68 Memo,6/5/68 No violations.
~
9/4-5/68 Ltr,11/6/68 Ref: License Conditio'n No. 8.
Sixteen to K-M eleven-liter bottles containing solutions of enriched uranium stored in a free stan condition in a scrap recovery area aisle.
l
~
I I
- - - - - - - ~ -
.-. m.
.e...
-a.--...
6 Dates of Description of Violations.
I inspection _
Report No.-
1/22-23/69.
Memo,2/7/69 No violations.
5/13-14/69 Ltr. 6/24/69 1.
Ref: 10 CFR 20.201(b). Inadequate
, evaluation of liquid effluents released
~
to K-M
~
to an. unrestricted a'res.
2.
Ref: 10 CFR 20.201(b). No surveys of contaminated laundry. area to determine if individuals veier ex36 sed to airborne radioactive material.'
e.
9/9-11/69 Ler,9/25/69 No violations.
~
to K-M 12/2-4/69 Ler,2/13/70 Ref: 10 CFR 20.201(b). Inadequate surveys to evaluate concentrations of radioactive to K-M material released in liquid effluents to the Cimarron River.
3/19-20/70 f.tr.4/9/70 1.
Ref: 10 CFR 20.201(b). Inadequate surveys to determine the presence and to K-M extent of radioactive contamination on surfaces throughout the production
~. r
~'
,..,.' }. ~ ~..-
areas.
2.
Ref: 10 CFR 20.201(b). No, surveys of airborne concentrations of radioact material to which employees were expos while working in the solvent extractic building. Also, radioactive. material released from that building.
j
~
3.
Ref: 10 CFR 20.201(b). No surveys of
~
airborne concentrations of radioactive l
material to which employees were exposed duriqs and subsequent to blender cleanout operations.
4.
Refa License Condition No. 8.
Eight
~
11 liter 5 inch diame bottles con-taining solutions of enriched uranium were stored a free standin condition.-
I 2
. D&.
f C!PM
/e, khf
}
l p
Dates of Inspection Report No.
Description of violations 5.
Ref: License Condition No. 8.
Nuclear safety aspects relative to the handling and storage of SNM were not
,, evaluated.
-6.
'Ref: License Amendment No.18.
Respirators were not satisfactorily fitted on personnel,nor always surveye "c-prior to re-use to assure decontaminat 5/15/70 Ler, 6/29/70 Noviol$tions.
to K-M 9/29-10/2/70 Ltr 10/19/70 Ref: License Condition No. 8.
Practice to K-M criticality evaluations were not peiformed at 90-day intervals.
1/19-21/71 Ltr 2/8/.71 No violations.
to K-M 4/21-23/71 Memo,5/10/71 No violations.
kO/18-20/71 070-925/71-03
' No violations.
2/14-18/72 070-925/72-01 No violations.
~
6/12-13/72 070-925/72-02 No violations.
~
2/12-16/73 070-925/73-03 No violations.
6/18-22/73 070-925/73-04 1.
Ref: Li
.SNM-928., Amendment 23.
linders containing heel Sev o
e swsea n the cylinder storage area without valve protectors.
2.
Raf: License SNH-928, Para. II
.3.c 10-gallon containers of de ' vere within 12 of ender ow nerete donut storage arra h has less than eigh inches of concrete around the periphy of the array. Also, a bucket containi uranium floor washings was stored
_ 3 _-
7% pp w be pelead in hG l
i
= - -
Dates of Inspection Report No.
Description of Violations against the blended ouder oncrete
~
donut storage array.
License SNM-928, License Appl.
3.
Ref:
S' EMG-SNM-1, I.6 Conformance to L d 10-gallon container 0-2 was stored in a non-desi ge area. Also, several pellet b$_ats in the storage rack exceeded th
. safe slab configuration.
- 4., Ref: License SNM-928, License Appl.
EMG-SNM-1, Para III.A.b.3.
Packages of vastes, greater,t Car Q O vai p per 235-u, stored in the high enu ched ar was not marked as to the quantity of 235-u present. Net weight in the packages exceeded 350 gram.
9/17-21 &
070-925/73-05 No violations.
26/73 10/19,25,26 070-925/73-06 No violations.
and 11/2/73 2/11-15/74 070-925/74-01 No violations.
5/20-24/74
. 070-925/74-03 No violations.
g*
. sb g
g 4-I i
}
q
f CRITICALITY AND, HEALTH PHYSICS PLUTO,NIUM INSPECTION AT KERR-McGEE Date of Report or Inspections Applicable No.
- Descriptions of Violation
?
5/13-14/70 Memo Report dated 6/12/70 (Compliance)
No violations.
~
8/3-f/70 Memo Report dated Form,AEC-592-(Two violations):
" 8/24/79 (Compliance) 1/ License Condition #24-Drums
'of pu waste stored in semi-trailer outside.
2.
License Condition #25-Bottles of low level pu nitrate solutions not continuously vented.
12/8-10/70 Memo Report dated Form AEC-592 (Three violations):
12/29/70(Compliance) 1.
Drums of pu waste. stored in semi-trailer outside. Contrary to License Condition #24.
Bottles of low level pu nitrate 2.
solutions not continuously vented.
Contrary to License Condition #25.
3.
Inventory of natural or depleted uranium in excess of authorized limit. Contrary to License Item 1
- 7.C.
License Amendment No. 4 issued 12/11/7C ccrrected these apparent deficiencies.
4/19-21/71
. M'emo Report dated 5/5/71 (Compliance)
No violations.
~
10/21-22/71 Memo Report #070-1193
/71-02 dated 11/15/71 No violat ons.
[
2/17-18/72 Memo Report #070-1193/
72-01 dated 3/3/72 No violations.
6/14-16/72 Memo Report #070-1193/
72-02 dated 7/17/72 No violations.
~
10/19-20/72 Rpt Ltr dated
- 11/10/72 Rpt Nos. 070-925/72-03 and 070-1193/72-03 No violations.
ha pje cDe n/c.-se a ua
^
^
I
s.
CRITICALITY AND REALTH PHYSICS PLUTONIUM INSPECTION AT KERR-McGEE (Continued)
Date of Repor.t or Inspections Applicable No.
Descriptions of Violation 2/12-16/73 Rpt Letter dated ~
Two violations-plutonium facility:
3/26/73. Rpt Nos.
1.
Nuclear criticality Safety Off '
070-925/73-02 &
and Licensing and Regulation O h 70-1193/73-02 did not audit monthly for com-
~
pliance with license requireme
~
and Nuclear Criticality Safety Contrary to SNM-ll74 Appendix 2.
Glove Box 23 in pu waste recov
~
not posted with hood inventory record. Contrary to SNM-1174,
]
Appendix A.
2/7, 8, 9, Rpt letter dated No items of noncott.pliance, but 13, 14, 28, 29/73 5/21/73 Rpt No.
Atems requiring immediate attentio 070-1193/73-04 1.
Delay in collecting bioassay samples and additional delay between time samples submitted-I and analytical results receive 2.
Medical consultant not notifie until day following the occurr 8
~
(fire).
j Prior to the fire, procedures 3.
not require respiratory protec during bag-out operations. Tt l
precaution would have reduced
~
intake of radioactive materia]
l personnel involved.
4.
Room Air Monitor Chart allovec run out the day before the fii Information to help evaluate concentraticas of radioactivit :
room air at time of fire was -
available. "
6/18-22/73 Rpt Letter dated Two violations-plutonium facility 8/17/73 Rpt No.
SNM-1174:
070-1193/73-05 1.
Glove Box 1A, Waste Processin:
Area, had no " Glove Box Statu.
Sheet" indicating fissile con Contrary to Appendix A of Lic SNM-1174.
~
I 8
k'sPJece\\be. rom)m Gk/.
~
1 l
t
... i..
i i
i
=
CRITICALITY AND HEA1.TH P.'iYSICS PLUTONIUM l
1 INSPECTION AT KERR-McCEE (Continued) 1 Date of Report or
' Inspections Applicable No.
Descriptions of Violation 2.
Glove Box 40 containsd thgee one liter centainers, two of which v
'less then 12" apart-violations o g,
postad Safe Operation limit whic limits glove box storage,to two one-liter containers and require 12" spacing between containers.
Contrary to Appendix A, of SNM-
~
1174, Operating Procedures and' Operating Responsibilities.
I 9/17,21,26/73 Rpt letter dated Seven violations-plutonium facility 11/7/73, Rpt No.
SNM-1174:
070-1193/73-06 1.
During the week of July 8-14, 19 employee exposed to airborne con I
centrations cf plutonium, when j
' averaged over 40, hours were 1.3
.~
e i
times the specified limits. Con
)
trary to 10 CFR 20.103'and limit in Appendix B. Table 1 of this part.
.", ~
2.
Required inspection.of Raschig rings not performed. Contrary t proposed ANSI Standard November 1965, and approved' ANSI Standard N16.4-1971 required inspections.
l 3.
On one occasion vaste shipment received on July 11, 1973, in a
" Poly Pagther" DOT SP 6272 packa j
Contrary to Sections 71-10 and 71-12 of 10 CFR 71. Another cas Waste shipment received June 5, 1973 in a " Super Tiger" DOT SP
~
f' 6400 package containing 3 drums I
of liquids. Contrary to License SNM-338 and Section 71-12(b) 10 CFR 71 and did not g
seet droo test requirements of g
Paragraph 173.393(g) DOT Regula-tions (Paragraph 20).
h{$
Q '( t)n N
- 3 ~
??
l i
- 5
=
. N l
=
)
CRITICALITY AND HEALTH PHYSICS PLUTONIUM
.e INSPECTION AT KERR-McGEE (Continued) e
.Date of Report or Descriptions of Violation Inspections Applicable No.
4.
Licensee changed organizational 3
structure combining responsibil-
~
ities of health and safety tech-nical posit; ions eliminating pos.$ti and filled' position of License and Safety Officer with an inexperienc employee. Not reported to AEC-Contrary to Appendix A, Licensee SNM-1174.
~
5.
No offsite survey performed on April 17, 1972 to evaluate con-sequences of two departing contam-insted employees.. Contrary to 1G CFR 20.201(b).
6.
On May 24 and June 4,1973 one hour tornado alerts received by licensee with the required Manage-ment appraisals not documented.
Contrary to Condition 18, License SNM-1174.
I Records were not maintained of th 7.
I Results of surveys f'or contamina-tion on the solid waste storage trailer prior to painting. Contr to 10 CFR 20.401(b) and 10 CFR 20.201(b).
10/19, 25, 26/73 Rpt Letter dated and 11/2/73 12/4/73 Rpt No.
070-1193/73-07 No violations.
2/11-15/74 Rpt letter dated SNM-1174. Tliree violations:
~
4/8/74, Rpt No.
1.
October 28 to Novenber 3, 1973, 070-1193/74-01 seven employees exposed to air-borne concentrations when average over 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> were in excess by 1.2 to 1.6 times the specified limits. Contrary to 10 CFR 20.1 ff (M
E VflCHe) ph hob l I
\\.
1
. -. ~ - - -
r-
.g CRITICALITY AND HEALTH PHYSICS PLUT0 nit M INSPECTION AT KERR-McGEE (Continued)
Date of
, Report or inspections Applicable No.
Descriptiens of Violation 2.
November 25-December 1,1973, one employaa engose,d to airborne concentrations, for 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> average of 1.5 times the specified limits. Contrary to 10 CFR 20.103. '
3.
Week of February 10-16, 1974, two employees exposed to airborne concentrations for 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> average
.of 1.4 times the specified limits.
Cont.rary to 10 CFR 20.103.
5/20-24/74 Rpt Letter dated SNM-1174-plutonium facility, five 6/20/74, Rpt No.
violations.
070-1193/74-05 1.
In-place DOP Testing of final high efficiency filters not perforr i
annually.
Contrary to License Condition No. 21.
2.
Licensee enrough its contracted nuclear safety consultant (Battelle Northwest) utilized Monte Carlo computer Code, KZNO, in criticalit.
safety analysis for vault storage.
Contrary to Item 8, License SNM-13 and Page 26, Appendix As 3.
Nuclear safety analyses made prior to 1973 not verified by the Licensing and Regulations Officer (1 of 8 only had been initiated b3 L&RO). Contrary to page 19.1, Appendix A, SNM-1174.
4.
No evidence that the physeial ins'pection of several equipment and facility changes had been made prior to usage. Contrary to Page 4, Appendix A, SNM-1174.
5.
Licensee using sub-floor storage wells in the Inspection and Asser bly Room (121) and Glove Box Stor:
i Wells in the Fabrication Room (12' Licensee requested an Amendment.
Contrary to Page 17.4 Appendix A, SNM-1174.
0 Dn U M th 15l f t i i i
{
j i.
i-
.