M 2NRC-7-076 (412)393 7546 Beaver Valley No. 2 Unit Project organization Telecopy(412)393 7889 S E.G. Building April 13, 1987 P.O. Box 328 Shippingport, PA 15077 United States Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, DC 20555

SUBJECT:

Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 PSI Progran, Safety Class 3 Support Welded Attachment Visual Exams.

REFERENCE:

BVPS-2 PSI Program Submittal Letter 2NRC-5-154, dated December 26, 1986 Gentlemen:

This letter is to document the telecon that occurred on March 26, 1987 between Messrs. Peter Tam and George Johnson (USNRC), and Messrs. R. M. Reba and L.

M.

Rabenau (DLC), (other participants identified on Attachment 1) regarding the subject examinations.

The topic discussed was the application of construction visual exanination results for Safety Class 3 support integral ly welded attachnents to satisfy ASME Section XI preservice examination require-ments for the same. During the discussion it was pointed out that ASME Section XI (80W80) IWB-1220 (Safety Class 1) and IWC-1220 (Safety Class 2) permit shop and field examinations to serve in lieu of on-site preservice exaninations provided applicable criteria are met.

IWD-2100 (Safety Class 3) does not pro-vide similar guidance.

Additionally, acceptance standards for Class 3 visual VT-3 examinations, LWD-3000 are in the course of preparation and guidance is not provided else-where in ASME Section XI.

In such cases, IWA-3100(b) directs us back to the construction code for applicable acceptance standards.

A review of Attachment 2, construction visual inspection attribute list indicates that a very strin-gent visual examination was implemented.

8704200331 870413 PDR ADOCK 05000412 A

PDR l

United States Nuclear Regulatory Commission PSI Progran, Safety Class 3 Support Welded Attachment Visual Exans Page 2 DLC and NRR mutually agreed that use of construction visual examination results in this application is an acceptable alternative for the IWD examina-tion in the ASME XI PSI Progran for BVPS-2.

DUQUESNE LIGHT COMPANY By Vd.y.Carey/ 1 Senior Vice President RMR/LMR/ijr NR/REBA/LMR/LTR Attachments AR/NAR cc:

Mr. P. Tam, Project Manager

- w/ attachments Mr. G. Johnson, NRR

- w/ attachments Mr. J. Beall, NRC Sr. Resident Inspector

- w/ attachments Mr. L. Prividy, NRC Resident inspector

- w/ attachments INPO Records Center

- w/ attachments i

l I

1

,, _. -. - ~., _. -. _.

j l

ATTACHMENT 1 PSI Program, Safety Class 3 Support Welded Attachment Visual Exams Telecon: March 26,1987; 3:40 PM

Participants:

USNRC:

Messrs Peter Tam, G. Johnson (NRR)

DLC:

Messrs. L. M. Rabenau (Licensing); R. M. Reba, P. A. Caaena (BV-2 Engineering); C. E. Ewing (QA Manager); W. H. Sikorski, D. P. Weakland, R. A. Perry (ISI Dept.)

ATTACHMENT 2 DUQUESNE LIGHT COMPANY Nuclear Group Quality Assurance Unit Inservice Inspection Department March 27, 1987 ND2ISI:0470 Class III Supports Mr. R. Reba:

The following information is being provided for your use or reference in the letter of notification to the USNRC for the utilization of construction visual examinations in lieu of the IWD PSI visual examinations of ASME Class III Supports.

I have reviewed IP-7.2 "ASME Section III & VIII Velding" and integral attachments were visually examined for the following attributes:

Coarse or irregular veld ripple which interferes with inspection a.

j b.

Unblended start or stops c.

Overlap d.

Porosity e.

Slag f.

Veld spatter g.

Arc strikes h.

Grooves 1.

Abrupt ridges and valleys

j. Excessive and non-uniform grinding k.

Excessive reinforcement 1.

Lack of sufficient reinforcement m.

Paint n.

Oil o.

Grease p.

Concrete spatter q.

Rust r.

Free of cracks, slag, slag inclusions The visual examination attributes noted above for IP-7.2 exceed the requirements of ASME Section XI for a VT-3 type visual examination that would be performed under PSI conditions.

l I

l

R. R;ba March 27,1987 ND2ISI 0470 Page 2 If any further questions arise, please call me at PAX 5850.

s9a.

Ronald A. Perry Supervisor, NDE Services RAP /jak cc:

C. E. Ewing M. J. O'Neil V. H. Sikorski D. P. Weakland ISI File Central File (2) i F