"FApT Telephone (412) 393-6000
.O. Box 4 Shippingport, PA 15077M4 June 1, 1988 U.
S. Nuclear Regulatory Commission Attn:
Document Control Desk Washington, DC 20555
Reference:
Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 Inservice Inspection Program (TAC 62873)
Gentlemen:
Enclosed is the 10 year plan for Inservice Inspection at BVPS-2.
Since the program incorporates various features which will require relief from specific portions of the code, the supporting relief requests are enclosed as part of this submittal.
In addition to the
- plan, a
piping weld examination summary is also included for your information.
This should fully satisfy paragraph 2.c(5) of the license.
i Sincerely 4 46 1
D. Sieber Vice President Nuclear Group Attachment cc:
Mr. J. Beall, Sr. Resident Inspector, w/ attachment Mr. W. T. Russell, NRC Region I Administrator, w/ attachment Mr. P. Tam, Project Manager, w/ attachment s
b O
1 k
8806060216 880601
~
PDR ADOCK 05000412 V
O DCD
UNIT II PIPING WELD EXAM
SUMMARY
CATEGORY B-J ITEM NO.
TOTAL WELDS REQUIRED EXAMS SCHEDULED EYAMS B9.11 458 115 120 B9.21 850 223 227 B9.31 13 4
4 B9.32 48 12 13 B9.40 225 57 59 CATEGORY C-F-1 SYSTEM TOTAL WELDS REQUIRED EXAMS SCHEDULED EXAMS ITEM NO C5.11 QSS 180 14 15 RHS 281 22 22 RSS 186 14 14 SIS 464 35 36 ITEM NO C5.21 CHS 578 44 45 SIS 369 28 28 ITEM NO C5.30 CHS 551 42 42 SIS 191 15 15 d
ITEM NO C5.41 CHS 6
1 1
SIS 9
1 1
QSS 2
0 N/A RHS 2
0 N/A CATEGORY C-F-2 ITEM NO C5.51 FWS 56 5
7 MSS 74 6
8 SVS 64 5
7 ITEM NO C5.52 MSS 48 4
5 ITEM NO C5.81 MSS 3
1 1
-