Confirms 860417 Telcon Agreements Re SER (NUREG-1057) Open Item 4 Concerning Preservice Insp Program,Including Exam of Component Supports & Break Exclusion Zone (Augmented Inservice Insp) Exam of 2-inch Welds & Smaller
ML18041A132
Person / Time
Site: Beaver Valley
Issue date: 05/13/1986
From: Carey J
DUQUESNE LIGHT CO.
To: Harold Denton, Tam P
Office of Nuclear Reactor Regulation
References
RTR-NUREG-1057 2NRC-6-047, 2NRC-6-47, TAC-62873, NUDOCS 8605190099
Download: ML18041A132 (8)


Text

~I cfi ACCESSION NBR:

FAC IL: 50-412 AUTH. NAME CAREY'S J. J.

REC IP. NAME DENTONp H, R.

TAMiP.

REQUL Y INFORMATION DISTRIBUTI SYSTEM (R IDS) 8b0519009'9 DOC. DATE: 8b/05/13 NOTARIZED: YES DOCKET I Beaver Valleg Power Station.

Unit 2>

Duquesne Light C 05000412 AUTHOR AFFILIATION Duquesne Light Co.

RECIPIENT AFFILIATION Off'ice of Nuclear Reactor Regulationi Director (past 851125 Divisian of Pressurized Water Reactor Licensing A (post 8

SUBJECT:

Confirms Sb0417 telcon agreements BER (NUREC-1057)

Open Item 4 cancerning preservice insp programs including (augmented inservice insp) exam of 2-inch toelds Sc smaller.

DISTRIBUTION CODE:

B001D COPIES RECEIVED: LTR ENCL SIZE:

TITLE: Licensing Submittal:

PBAR/FSAR Amdts 5 Related Correspondence NOTES:LPDR 2cgs Transcripts.

LPDR 2cgs PDR Documents.

Application for permit renetual filed.

05000412 RECIPIENT ID CODE/NAME PMR-A ADTS PMR-A EICBB PMR-A PD2 LA TAMiP PWR-A RBB 01 INTERNAL: ACRS 41 ELD/HDBS IE/DEPER/EPB Sb NRR BWR ADTS NRR PWR-B ADTB HFIB EQ FIL 04

/D I/MIB NOTES:

EXTERNAL: 24X DMB/DBS (AMDTS)

NRC PDR 02 PNL GRUEL. R CL 6

1 1

1 1

1 1

1 1

1 1

1 1

COPIES LTTR EN 1

2 1

2 1

RECIPIENT ID CODE/NAME PWR-A EB PWR-A FOB PMR-A PD2 PD PWR-A PSB ADM/LFMB IE FILE IE/DGAVT/GAB 21 NRR PWR-A ADTS NRR ROEi M. L NRR/DHFT/MTB RQN1 BNL(AMDTB ONLY)

LPDR 03 NSIC 05 COPIES LTTR ENCL 1

1 1

1 1

1 3

'OTAL NUMBER OF COPIEB REGUIRED:

LTTR 42 ENCL

<BGIR) V~STBYB,ITUGIRTBra NQITAIIRQ-Il~ir YS.

~JUa"=R TB]IOQG 8 JY

".G~~Z IRATQN CEXCOXaB:STAG.3QG V'POOCkG068:RGN NQIB8333A gk&000dO 3 ditpi J err~>>evpua iQ dirtU irioidsdB veiiia9 Mef fcV vovseG Gkk-OU:JI3A'9 YQITAKJIB'9A RQHTUA JI'tAYi.HTUA

.oD dilgiJ eriaeupua

.L iYBAAD YiQITAIJI=I9A TN~~IRI33R-

'9I'IAN.9 I33R QCk kBU dao q) mad sepia

.rioi$s EugeR mod sreR use Eauh

%o a> i%%0

,R.H,NQl NHG 8 daoq)

A prrioire~i I vodvceR vedeM bezivuaaev9

%a rroiaivia I it'IAT naqQ (WCOk-Q. RUN)

R38 adrremee~ps rioofed Vk40c38 emvi%rio3:T3BLGUB grribuf arri ims~povq qarii evivee ezq prrirrve~rio~ I'ed I

. ieEEcm=

iS zbfovs rlvrri-9 %o mixe (qarri eaivvoorri bedriemnus)

a~f8 J3Na ~ RTJ:Gzvla3aR Bal903 GkOOG
aa03 NQITUGIRTBla evriebrraqr gzvo3 bedsf eR P

adbmA RAB'9XRAB I:EcddimduB gnienesi J:3 ITIT

~~k4 COOP,O

.adrremuvaa RG I apv9 RG'IJ

.adqivaeoovT agvG RG9J:83TQN

.befi%

Esizerree dimveq vo'I rraidi vifqqA 83I IQ3 JDNB AT I J I

I 0

k k

k 0

k TN3I'II33R BICANXBGQ3 a I G3 A-RM9 GQR A-RM9 G I RG9 A-RM9 689 A-RM'9 Gt'I'9JX NGA BJI'9 3I GASXTVAGGX3I BTGA A-RM I RRYi I.N i30R RRN G Tweak'SHGX RRN kNQR (Y ]NQ BTGNA)JNG CO RG IJ GO 3IBN 6

I k

k k

'k BZI903 JDN"=I RTT.l k

cJ Il:

k I.

!i

,Q lO

0 Q

TN3I9I3~R HIIAViXBGQ3 Gl BTaA A-RM9 G83I3 A-RM9 AJ QG I A-RM9 I iNAT GBR A-RM9 kO kb BROA

!JANRHTNI CBGHXGJ:I aC GWXR39sasaf BTGA RMG RRN BTGA G-RW I ARIA GIIHXTRI]GXRRN

<0 HJI9 SBP GItliIt'IAGGitIR XIig:JANR3TXB (BTGNA) BBGXGNG

~0 RG9 3RN R,JOUR!) JYiq 83TQN JDNB RA FTTJ

'GDRIUGRR BDI903 10 A3GICUN JATQT

~A@

Duqumne Ut Nuclear Construction DivisIon Robinson Plaza, Building 2, Suite 210 Pittsburgh, PA 15205 2NRC-6-047 t412) 787-5141 (412) 923-1950 Telecopy (412) 787-2829 May 13,,

1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Mr. Peter Tam, Project Manager Division of PWR Licensing - A Office of Nuclear Reactor Regulation

SUBJECT:

Beaver Valley Power Station - Unit No.

2 Docket No. 50-412 SER Open Item (4)

REFERENCE:

1)

BVPS-2 Safety Evaluation Report, NUREG-1057, October 1985 2)

DLC Letter 2NRC-5-154, dated December 26, 1985 3)

NRC Letter to DLC, dated January 24, 1986 4)

DLC Letter 2NRC-6-034, dated April 9, 1986 GENTLEMEN:

As a

follow-on to submittal of the BVPS-2 Preservice Inspection Program (reference 2),

Duquesne Light Company (DLC) held a telecon with your staff (Messrs.

P.

Tam, G.

Johnson and S.

Lee) on April 17, 1986 relative to PSI examination of component supports and Break Exclusion Zone (Augmented ISI) examination of welds 2 inch and smaller size.

Agreements reached on the examinations relative to the above are as follows:

1.

Preservice Inspection of Com onent Su orts ica e to Wl- -

00 The ASME Section XI Code, 1980 Edition through Winter 1980 Addenda (BVPS-2 PSI Program Baseline) states in IWF-2200(b): nAll examinations shall be performed following the initiation of hot functional tests."

In the DLC submittal PSI Program Document No.

NCDP 2. 13, paragraph 6.7.3, the following was stated as a clarification:

nDLC applies the IWF-2200(b) criteria to nHotn ()200'F) systems."

The discussion with your staff estabished and clarified that the concern for application of IWF-2200(b) was for component supports subject to thermal stresses and/or movements, and was therefor e Sb051't)00's)ts)

Sb05i3 PDR ADOCK 050004i2

'E PDR

I*,

VHP, P t

" li'

~ h' 1

'f I

V'

',I f

H II P

H I

IHP t

h tH I

~

~

Vf

United States Nuclea egul atory Commission Beaver. Valley Power ation-Unit 2 SER Open Item (4)

Page 2

applicable to those systems which are subjected to "Hot" temperatures.

The establishment of a system operating temperature of ")200'F" as being "Hot" was agreed upon.

Therfore no change to NCDP 2.13 is necessary.

2.

3.

Preservice Ins ection Examination Re uirements of Com onent u

orts a p scab e to IWF-2200 a

vs.

IWF-25 0 a

and b

The ASME Section XI

Code, 1980 Edition through Winter 1980 Addenda (BVPS-2 PSI Baseline) states in IWF-2200(a): "All examinations listed in IWF-2500-2 shall be performed completely,
once, as preservice examination."

In the DLC PSI Program procedures for component supports (not includ-ing snubbers, which are examined 100K in PSI) and in DLC Program Pro-cedure NCDP 2.13. 6, paragraph

6. 1. 2 (submitted with BVPS-2 PSI
Program, reference 2),

selection of component supports utilizes IWF-2510(a) and IWF-2510(b).

The di scussi on with your staff establ i shed and cl arified that the selection of components supports for PSI utilizing IWF-2510(a) and (b) will meet the intent of providing an examination baseline for In-service Inspection.

DLC also indicated that in addition to utilizing multiple stream (train) and multiple components criteria for establishment of "all in one train" of component

supports, all Class 1

component (piping) supports applicable to Class 1 i ntegraT (piping) attachments, which were selected from any of the multiple

trains, would also be included in the examination requirements.

Pro-cedure 2.13.7 will be changed to reflect the above.

Preservice Ins ection of 2 inch and Smaller Welds in Brea xc usion one u mente Ins ection The BVPS-2 FSAR (section 6.6.8) and DLC submitted PSI Procedure NCDP

2. 13, paragraph 6.5.5 identified Break Exclusion Zone (Augmented ISI) and extent of examinations.

DLC submitted PSI Procedure NCDP 2. 13.5, step 6.2.2.5, "Limitations/Clarifications", further indicated that:

"Miscellaneous branch connections and socket welds (1 1/2 inch.

and 2

inch. sizes) are not included in the PSI examination."

The agreement reached is based on the folowing:

(a)

The specific requirements for Break Exclusion Zone piping welds is for a

"volumetric only" examination (ultrasonic methods at BVPS-2).

(b)

Obtaining meaningful results by ultrasonic methods for miscel-laneous branch connections and socket welds (1

1/2 inch and 2

inch sizes) is highly improbable.

(c)

The intent of PSI examination as a baseline for ISI is to provide for trending service-induced degradation.

~

4

~

~

uaited States Nuclea gul atory Commission Beaver Valley Power ation-'Unit 2 SER Open Item (4)

Page 3

The agreement reached is to perform surface examinati'on with sampling criteria compatible with Class 2 weld selection criteria for PSI (i.e.

1 0 X sampling, prorated).

An FSAR Amendment to paragraph 6.6.8 and revision to NCDP 2.13.5 will be forthcoming to incorporate the above clarifications.

In-process examination of Break Exclusion Zone piping welds will also incorporate this criteria.

The above items should be considered part of the PSI Program submittal which is presently under staff review and for which a confirmatory status of the part of SER Open Item (4) concerning PSI has been requested by July 1, 1986 (reference 4).

DUQUESNE LIGHT COMPANY

/jdw AR NAR By J.

J.

Ca y

Vice President cc:

Mr. P.

Tam, Project Manager Mr. J.

M. Taylor, Director (3)

Mr. M. Troskoski, Sr. Resident Inspector Mr. L. Prividy NRC Resident Inspector INPO Records Center NRC Document Control Desk CRIBED AN ORN TO BEFORE ME THIS DAY OF