r a

..e..,

.^

ConSum8f5 POW 8r e

Company w m:

b$U c.-..' o " c.. 2i2 weit v. cms n A.aw., secssoa. ui 49201. (sivi 7ss osso July 10, 1986 Mr Fred Morley District Supervisor Michigan Department of Natural Resources Plainwell District Office Building 621 North Kent Street PO Box 355 Plainwell, MI ~49080 FILE NO:

P10.2.1 LTI 950/72*40*05/3 Years INCIDENT NO: PAL-86-06-NC126 This is in regard to NPDES Permit No MI 0001457 for the Company's Palisades Plant.

In accordance with Part II, A4, the attached " NPDES Notification,"

Incident No PAL-86-06-NC126 is submitted as a report of an apparent difference from the monthly average effluent limitations for this facility.

If you have any questions regarding the attached report, please contact this office.

~[Lc

[b O R L Fobes Senior Environmental Advisor BCC KF l

SFPierce, Palisades i

ATUdrys, M-1023 l

pea 21ggggggggggp l

S l

OC0786-25RLF-ENO3 i

r 8

File No P10.2.1 Incident No: PAL-86-06-NC126 NPDES NOTIFICATION Apparent Difference From Monthly Average Limitation Plant: Palisades Permit No: MI 0001457 Outfall

Description:

Neutralizer Tank Outfall Codh No: 800213 Discharge (00E)

Parameter: Total Suspended Solids Parameter Code No: 00530 1.

Date of Incident: June 30, 1986 2.

Identification of specific effluent limitation or monitoring requirement affected:

Monthly average limit of 30 mg/L total suspended solids 3.

Description of Incident:

The June monthly average total suspended solids concentration for the neutralizer tank was 36.2 mg/L.

4.

Apparent Cause:

The neutralizer tank was released on June 3, 1986 with a suspended solids content of 72.2 mg/L (the tank contained a high level of rusty. water). The two remaining tanks reIcased on June 28 and June 30 contained 9.7 and 26.6 mg/L suspended solids, respectively.

5.

If not immediately corrected, the anticipated time the condition is expected to continue:

N/A 6.

Corrective Action - The following corrective action was take,n or will be taken to reduce, eliminate and prevent recurrence:

Oniv in an emergency situation will the neutralizer tank be released with suspended solids greater than 30 mg/L.

7.

Additional Comments:

N/A 8.

Signed:

Ronald L Fobes RP0786-25RLF-ENO3