ML20214K170

From kanterella
Jump to navigation Jump to search
Proposed Changes to Tech Specs,Deleting Tech Spec 5.3.1.6 Re Amount of Enriched Fissionable Matl Allowed Onsite for Neutron Flux Monitoring Purposes
ML20214K170
Person / Time
Site: Robinson 
Issue date: 08/13/1986
From:
CAROLINA POWER & LIGHT CO.
To:
Shared Package
ML14190A945 List:
References
(HBR-35), NUDOCS 8608180196
Download: ML20214K170 (1)


Text

. _

l i

(HBR-35)

,. 1 9

5.3 REACTOR 5.3.1 Reactor Core 5.3.1.1 The reactor core contains approximately 68 metric tons of uranium in the form.of natural or slightly enriched uranium dioxide pellets. The pellets are encapsulated in Zircaloy-4 tubing to form fuel rods which are all pre pressurized. The reactor core is made up of 157 fuel assemblies. Each fuel assembly contains 204 fuel rod locations occupied by rods consisting of natural or slightly enriched uranium pellets, solid inert materials, or a combination of the aforementioned.II) 5.3.1.2 Deleted.

5.3.1.3 Reload fuel will be similar in design to the initial core. The enrichment of reload fuel will be no more than 3.5 weight percent of U-235.

5.3.1.4 Deleted.

5.3.1.5 There are 45 full-length RCC assemblies in the reactor core. The full-length RCC assemblies contain 144 inch segments of silver-indium-cadmium alloy clad with the stainless steel.(2) 5.3.1.6 Deleted.

l 5.3.2 Reaccor Coolant System 5.3.2.1 The design of fb.c Reactor Coolant System complies with the Code requirements.(3) 1 8609180196 h h 61 ADOCK PDR PDR P

5.3-1 Amendment No.

l

_