_

JMarch 4, 1987-

~

.t

. Docket No. 50-325 DISTRIBUTION

.tEiiEEE3NF NRC PDR/ Local PDR Mr. E. E.. Utley -

~

PD#2_ Plant

-Senior Executive Vice^-President RM8ernero Power Supply and Engineering & Construction OGC-Bethesda~

s Carolina Power & Light Company

~Edordan/BGrimes

' Post Office Box 1551-JPartlow/NThompson 3

Raleigh, North Carolina 27602 ESylvester/SNorris ACRS(10)

Dear Mr. Utley:

SUBJECT:

INTERGRANULAR: STRESS' CORROSION CRACKING (IGSCC) INSPECTION PROGRAM FOR RELOAD 5 0UTAGE v

Re:

Brunswick Steam Electric Plant, Unit 1-By.' letter dated October 31, 1986, you submitted your plans for the-intergranular stress corrosion cracking (IGSCC) inspection program to be performed during the Brunswick Unit 1 Reload 5 outage which began February 14, 1987. -You indicated that the IGSCC inspections will be performed by EPRI-qualified ultrasonic testing (UT) personnel using the General Electric Company automated SMART UT system where physical clearances allow. The proposed IGSCC inspection program consists of (1) inspecting all class 1 austenitic stainless steel welds susceptible to IGSCC (75 welds), (2) upgrading and inspecting a minimum of 11 overlay repaired welds, and (3)

-inspecting the Inconel butter welds in the recirculation and core spray systems in accordance with IE Notice.84-41.

We have completed our r.3 view of the proposed Reload 5 outage IGSCC inspection program as described.in your October 31, 1986 letter. Based on our review we find that your program meets the guidelines of Generic Letter 84-11, and is, therefore, acceptable.

' Sincerely, George Rivenbark for Daniel R. Muller,. Director BWR Project Directorate #2 Division of BWR Licensing cc:

See next page DBL:PD#2 DBL:PD#2 DB D#2 SNW ESylvester:cd

_DR ler 3/.4 /87 3/ t /87 3/4{/87 0FFICIAL RECORD COPY 87030

{ f50 25 gDR ppg O

Mr.'E. E. Utley Brunswick Steam Electric Plar.t

~"

Carolina Pcwer & Light Company Units 1 and 2 cc:

Mr..P. W. Howe Mr. C. R. Dietz Vice Presider.t Plant General Manager Brunswick Nuclear Project Brunswick Kuclear Project Box 10429 Box 10429 Sc.uthpert, North Carolina 28461 Southport, North Carolina 28461 Thoras A. Eaxter, Esquire Mr. H. A.. Cole

.Shaw, Pittman, Potts & Trowbridge Special Deputy Attorney Ger.eral 2300 N Street, N. W.

State of North Carolina Washington, D. C. -20037 Post Office Box 629 Raleigh, North Carolina 27602 Mr. D. E. Pcilar Associate Ger.eral Counsel Mr. Robert P. Gruber Carolina Pcwer & Light Company Executive Director Post Office-Box 1551 Public Staff - NCUC Raleigh, North Carolina 27602 Post Office Box 29b20 Raleigh, North Carolina 27626-Ob20 Mr. Christopher Chappell, Chairman Board of Commissioners Post Office Box 249 Eolivia, North Carolina 28422 Itrs. Chrys Baggett State Clearinghouse Budget and Management 116 West Jones Street Paleigh, North Carolina 27603 Resident Inspector U. S. Nuclear Regulatory Commission Star Route 1 Pest Office. Box 208 Scuthport, North Carolina 28461 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, Suite 2900 Atlanta, Georgia 30303 Mr. Dayne H. Brown, Chief Radiation Protection Branch Division of Facility Services N. C. Department of Human Resources 701 Barbour Drive Raleigh, North Carolina 27603-2008