M AINE Y ANKEE OTOMIC POWER COMPAP$Y ATTACHMENT B The Annual Radiological Environmental Operating Reports shall include summaries, interpretations, and an analysis of trends of the results of the radiological environmental surveillance activities for the report period, and an assessment of the environmental impact of plant operation, if any.
The reports shall also include the results of the land use censuses required by Specification 4.8.B.
The Annual Radiological Environmental Operating Reports shall include summarized and tabulated results of radiological environmental samples taken during the report period pursuant to the tables and figures in the ODCM.
In the event that some results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted as soon as possible in a supplementary report.
The reports shall also include the following:
a summary description of the radiological environmental monitoring program including a map of all sampling locations keyed to a table giving distance.s and directions from the reactor; and a discussion of all analyses in which the LLD required by Table 4.8-2 was not achievable.
5.9.1.6 Radioactive Effluent Reoorts
]
5.9.1.6.1 Semiannual Radioactive Effluent Release Reoort
]
Routine Radioactive Effluent Release Reports covering the operating of the unit during the previous 6 months of operation shall be submitted within 60 days after January 1 and July 1 of each year.
The Radioactive Effluent Release Reports shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit with data summarized on a quarterly basis.
3 The Radioactive Effluent Release Reports shall include the following information for each class of solid waste (as defined by 10 CFR Part 61) shipped off-site during the j
report period:
a.
Container volume.
b.
Total curie quantity (specify whether determined by measurement or estimate).
c.
Principal radionuclides (specify whether determined by measurement or estimate).
d.
Source waste and processing employed (e.g., dewatered spent resin, compacted dry waste, evaporator bottoms).
1 5.9-3 02/19/87 P
8226L-LHO
MAINE YANKEE ATOMIC POWER COMPANY e.
Type of container (e.g., LSA, Type A, Type B, Large
. Quantity).
f.
Solidification agent or absorbent (e.g., cement, asphalt.
"Dow").
The Radioactive Effluent-Release Reports shall include a list and description of unplanned releases from the site-to-site boundary of radioactive materials in gaseous and liquid-effluents made during the reporting period.
The Radioactive Effluent Release Reports shall include a listing of new locations for dose calculations and/or environmental monitoring identified by.the land use census pursuant to Specification 4.8.B.
The Radioactive Effluent Release Reports shall include changes to the ODCM for information.
5.9.1.6.2 Estimated Dose and Meteoroloaical Summary Reports
]
A.
A report of the estimated maximum potential doses to the
]
members of the public from radioactive effluent releases for
]
the previous calendar year shall be submitted within 90 days
]
after January 1 of each year. The assessment of radiation
]
doses shall be performed in accordance with the Off-Site Dose
]
Calculation Manual (ODCM).
]
B.
An annual summary report of hourly meteorological data
]
l collected over the previous year shall either be submitted
]
within 90 days after January 1 of each year or be retained in
]
a file that shall be provided to the NRC upon request. This
]
annual summary may be either in the form of an hour-by-hour
]
listing on magnetic tape of wind speed, wind direction,
]
atmoshperic stability, and precipitation (if measured) or in 1
the form of joint frequency distributions of wind speed, wind
]
direction, and atmospheric stability.
]
5.9.1.7 Soecial Reporti Special reports shall be submitted to the Regional Administrator of the Regional Office of the NRC within the time period specified for each report. These reports shall be submitted concerning the activities identified below pursuant to the requirements of the
~
applicable specification or rule.
a.
Reactivity Anomalies, Specification 3.15.
b.
Excessive radioactive release, Specifications 3.168, 3.17B,
]
and 3.17C.
]
c.
Plans for restoration of 115 kV service, Specification 3.12.
d.
Total Dose, Specification 3.16 and 3.17.
5.9-4 02/19/87 8226L-LM0