BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the matter of

)

NEW YORK POWER AUTHORITY

)

Docket No. 50-333 James A. FitzPatrick Nuclear Power Plant)

APPLICATION FOR AMENDMENT TO OPERATING LICENSE Pursuant to Section 50.90 of the regulations of the Nuclear Regulatory Commission, the New York Power Authority, as holder of Facility Operating License No. DPR-59, hereby applies for an Amendment to the Technical Specifications contained in Appendix A of this license.

The proposed changes to Sections 3.5.A.5 and 4.5.A.5 on page ll5a would eliminate the operability and testing requirements for the two recirculation pump discharge bypass valves.

These valves and their

~ associated piping are to be removed during-the January 1987 refueling outage at the recommendation of the reactor manufacturer, General Electric.

In addition, the removal of these valves and pipe will eliminate the potential for pipe failure due to intergranular stress corrosion cracking (IGSCC).

The proposed change page to the Technical Specification is Attachment I to this application.

The Gafety Evaluation for this change is included as Attachment II.

New York Power Authority J6hn C.

Brons enior Vice President uclear Generation STATE OF NEW YORK COUNTY OF WESTCHESTER Subscribed and sworn to before me this y

day of gefoh 1986.

bh b bNb Notary Public BAR8 ARA ANN McGUIRE Notary Public, State of New York No. 4851437 Quellflod in Putnam County Commiselon Empires Jsn. 27,19.yy-8610220020 961008 PDR ADOCK 05000333 P

PDR

-