ML20210L826

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Device Cigarette QA Gauge Source Holder for Model H1347.Certificate:NR-345-D-801-S
ML20210L826
Person / Time
Issue date: 09/30/1992
From: Steven Baggett
NRC
To:
Shared Package
ML20210L342 List:
References
SSD, NUDOCS 9708210322
Download: ML20210L826 (4)


Text

_ _ _ - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ .

A i

-REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES '

SAFETY EVALUATION OF DEVICE No.: NR-345-D-801-S DATE: SEP 3 01992 PAGE 1 OF 4 DEVICE TYPE: Cigarette Quality Assurance Gauge Source Holder MODEL: H1347 DISTRIBUTOR: Hauni Richmond, Inc.

2800 Charles City Road  ;

Richmond, VA 23231 MANUFACTURER: Hauni-Werke Korber and Company K.G.

  • Hamburg, West Germany SEALED SOURCE MODEL DESIGNATION: Amersham Model SIC-7007 9

ISOTOPE: MAXIMUM ACTIVITY:

Strontium-90/ Yttrium-90 5 millicuries LEAK TEST FREOUENCY: 6 Months PRINCIPAL USE: (E) Beta Gauges CUSTOM DEVICE: YES X NO 9708210322 970611 PDR RC

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.1 NR-345-D-801-S DATE: SEP 3 01992 PAGE 2 OF 4 DEVICE TYPE: Cigarette Quality Assurance Gauge Source Holder DESCRIPfION:

The bronze device has the physical appearance of a box approximately 8-1/2" in length, 3-1/2" in height, and 3-1/4" in width, with a titanium " measuring tube" and " rod guide" passing through the 3-1/4" dimension of the box near one end.

The measuring head, consisting of a bronze box containing the source, ionization chamber, and other electrical components, is attached to the remainder of the device, the mounting bracket, by means of a dovetail extending the length of the head. The measuring head sliden into a dovetailed slot on the mounting bracket where it is held in position by means of a " safety lock" (requires key to unlock) and a set screw. In order to gain access to the source it is necessary to remove the measuring head from the mounting bracket, remove the metal plates secured to the end of the head by screws, and then remove the brass bar (secured ugjp-in place with two screws) on which the foil type source is ,

secured. The source is secured in a depression in the brass bar by means of a titanium foil placed over it and held in place by 4 screws which secure two metal plates bearing on two edges of the titanium foil.

The measuring tube passes between the source and the ionization chamber so that the radiation from the source may penetrate the 0.1 mm wall tube and the cigarette rod and enter the ionization chamber. The distance from the source to the ionization chamber is approximately 15 mm.

LABELING:

The device bears a metal label 52 mm by 74 mm, purple on yellow, with the radiation symbol, the radioisotope and amount of radioisotope, and the wording " CAUTION-RADIOACTIVE MATERIAL."

The brass bar on which the source is mounted does not bear a label.

l

4 1

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE HQui NR-345-D-801-S DATE: SEP 3 01992 PAGE 3 OF 4 DEVICE TYPE: Cigarette Quality Assurance Gauge Source Holder EXTERNAL RADIATION LEVELS:

With the device mounted on the cigarette machine (" measuring tube" empty, i.e. , no cigarette rod present) , radiation levels at one foot from the device in areas accessible to individuals (including extremities) do not exceed 5 mr/hr. With a cigarette rod in the tube (machine operating) these levels drop to 0.3 mr/hr maximum and 0.2 mr/hr average.

OUALITY ASSURANCE AND CONTROL:

Hauni Richmond, Inc. maintains a quality assurance and control program which has been deemed acceptable for licensing purposes by NRC. A copy of the program is on file with the Source Containment and Devices Branch.

I

, LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

The devices have been distributed to persons specifically licensed by the NRC or an Agreement State.

Handling, storage, use, transfer, and disposal: To be determined by the licensing authority.

These devices shall be leak tested at intervals not to exceed 6 months using techniques capable of detecting 0.005 microcurie of removable contamination.

This registration sheet and the information contained within the references shall not be changed without the written conaene of the NRC.

SAFETY ANALYSIS

SUMMARY

Since 1979 the Model H1347 has not been a product manufactured by Hauni Richmond, Inc. In addition, since 1979 Hauni Richmond, Inc. has not offered any service / support of the device.

Hauni Richmond, Inc. states that they have no knowledge of any gauges still in use.

l

.? ,_ , r.

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-345-D-801-S DATE: Si s1992 PAGE 4 OF 4 DEVICE TYPE: Cigarette Quality Assurance Gauge Source Holder

REFERENCES:

The following supporting documents for the Model H1347 are hereby

-incorporated by reference and are made a part of this registry document.

  • Hauni Richmond, Inc. letters dated July 23, 1991, January 22, 1970, December 18, 1969, November 3, 1969, October 2, 1969, September 19, 1969, September 3, 1969, August 21, 1969, May 9, 1969, and May 2, 1969, with enclosures thereto.

ISSUING AGENCY:

U.S. Nuclear Regulatory Commission Date:

SEP 3 01992 Reviewer: M/ // O Date:

SEP 3 01992 Concurrence: 8 6'/q[7 g-4

_.- - - - - _ - _ - _ _