Provides Advance Notification of one-time Shipment of Trojan Reactor Vessel Package for Burial at Us Ecology Disposal Facility Near Richland,Wa,Per 10CFR71.97
ML20210L010
Person / Time
Site: 07100327
Issue date: 07/28/1999
From: Murdock M
PORTLAND GENERAL ELECTRIC CO.
To: Otto G, Stewartsmith
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV), OREGON, STATE OF, WASHINGTON, STATE OF
References
NM-014-99, NUDOCS 9908090017
Download: ML20210L010 (9)


Text

~

e k.

7 77 r 7

q~~~

E AUG 0 21999 Portland General Electric Company Trojan Nuclarr Plant YG.

71760 Columbia River Hwy 9y 1

Rainier OR 97048

-J (503)5563723 July 28,1999 1

MM-014-99

{

Mr. David Stewart-Smith Administrator, Energy Resources Division Oregon Office of Energy 625 Marion Street

' Salem, OR 97301-3742 I

Lieutenant Gail R. Otto Washington State Patrol PO Box 41600 Olympia, WA 98504-2600 Administrator, USNRC Region IV 611 Ryan Plana Drive, Suite 400 Arlington, TX 76011 Chairman of County Commissioners Columbia County Courthouse St. Helens, OR 97051

Dear Sir or Madam:

Advance Notification of Shipment of Troian Reactor Vessel Package Pursuant to 10 CFR 71.97 Pursuant to the requirements of 10 CFR 71.97," Advance Notification of Shipment ofIrradiated j

Reactor Fuel and Nuclear Waste," Portland General Electric Company (PGE) herein provides I

advance notification of the one-time shipment of the Trojan Reactor Vessel Package (TRVP) for

[

burial at the US Ecology d'.posal facility near Richland, Washington. Shipment of the TRVP will be conducted in accordance with 1) Nuclear Regulatory Commission (NRC)" Authorization of the Trojan Reactor Vessel Package for Transport," dated October 29,1998, as revised by NRC authorization letters dated July 16,1999 (Revision 1), and July 19,1999 (Revision 2); 2) PGE's Quality Assurance Program Approval for Radioactive Material Packages No. 0327, Revision 9, (p

dated April 28,1999 (Docket No. 71-0327); and 3) United States Department of Transportation j Exemption DOT-E-12147 (Second Revision).

/}

~

9900090017 990728 PDR ADOCK 07100327 C

PDR Connecting People, Power and Possibilities y_

G...

I J

MM-014-99

' July 28,1999 Page 2 of 2 If you have any questions concerning this notification please feel free to call me at (503) 556-7682.

Sincerely, i

YY Michael Murdock Radioactive Waste Supervisor I

Enclosure (s): Attachment 1 RP Forms 88 & 88a (pages 1 through 5) i to TPP 29-11 MM\\mjp

P, RC 0 Ji 3

CFP POW ST OP 7-5 OOR CFP

      • QA RECORD WHEN COMPLETED ***

Letter No.

N/A System No.

N/A No. of Pages Document Date 10 CFR 71.97 NUCLEAR WASTE SHIPMENT NOTIFICATION FORM Shipment Identification No.

NPF1 July 28.1999 NRC License No.

Today's Date (Mo/ Day /Yr) 1.

Shinper 2.

Carrier Same as Block #1 for Water; for a.

Name Portland General Electric Land Transport:

Troian Nuclear Plant

a. Name Columbia Pacific Transnort
b. Address 71760 Columbia River Hwy
b. Address PO Box 6510 Rainier. Oregon 97048 Kennewick. Washincton 99336
c. Tel. No. (503) 556-7682 (days)
c. Tel. No. (509) 586-0411 (503) 556-7252 (nights) 3.

Receiver a.

Name U.S. Ecology

b. Address P.O. Box 638 Hanford Reservation O

Richland. Washington 99352 c.

Tel. No. (509) 377-2411 4.

Descrintion of Waste:

a.

Proper Shipping Name Highway Route Controlled Ouantity of Radioactive Material.

N.O.S. 7. UN2482

b. The Hazard Class Radioactive 7 c.

Identification Number UN2982

d. Total Quantity in Shipment (Ci) 5.72E+10MBg (1.54E+6 curies) e.

Basic Description Troian's Reactor Vessel and Intemals. stabilized with concrete to a non-dispersable form f.

Type of Packaging Exclusive Use. Type B. as exemnted by: DOT - E - 12147

g. Name of Each Radionuclide (list all)(use back for additional space):

H-3. C-14. Mn-54. Fe-55. Co-60. Ni-59. Ni-63. Sr-90. Nb-94. Tc-99. Sb-125. Ce-144.

Eu-152. Pu-238. Pu-239. Pu-241. Pu-242. Am-241. Cm-242. Cm-243. Cm-244.1-129

h. Physical or Chemical Form Solid. Activated Metals. Metal Oxides
i. Category of Label Yellow III
j. Transport Index (Dose Rate at 1 Meter) 25 S

RP Form 88 RP 304 Revision 0 Page 1 of 5 Page 14 of 22 l

)

f.

i Shipment identification No.

NPF1 July 28.1999 NRC License No.

Today's Date (Mo/ Day /Yr) 5.

Additional Information for a 10 CFR 71.97 Shipment of Nuclear Waste a.

The street address of point of origin is:

Troian Nuclear Plant. 71760 Columbia River Highway (U.S. 30). Rainier. Oregon 97048

b. Tbc shipment is scheduled to begin during the seven-day period commencing August 5.1999
c. Schedule for shipment entry into indicated state (s):

S. tate Entry is scheduled during Washington (during river transoort) the 7-day period commencing Navigable Waters August 5.1999 Washington Land (Port of Benton)

August 7.1999

d. The street address of the shipment destination is U.S. Ecology.1/4 mile East of 200 West.

I Hanford Reservation. Richland. Washington 99352 The shipment is scheduled to arrive at the destination during the seven-day period e.

commencing August 7.1999 f.

Current information concerning the shipment can be obtained from:

Name Michael Murdock Address Troian Nuclear Plant 71760 Columbia River Highway Rainier. Oregon 97048 Tel. No.

(503) 556-7682 Area Code (Tel. No.)

6.

This information is being provided by:

Organization Portland General Electric By Michael Murdock Address Troian Nuclear Plant 71760 Columbia River Highway Rainier. Oregon 97048 7.

Verification of Notification of Receipt:

Person Contacted (1)

Agency Phone (2)

(3)

Verified By Title / Position

Date_,

RP Form 88 RP 304 Revision 0 Page 2 of 5 Page 15 of 22

llIGHWAY ROUTE CONTROLLED QUANTITY SlilPMENT NOTIFICATION FORM Shipment identification No.

NPF1 July 28.1999 NRC License No.

Today's Date (Mo/ Day /Yr) 1.

Shipper 2.

Carrier Same as Block I for water; for Land

a. Name Portland General Electric Transport:
b. Address 71760 Columbia River Hwv.
a. Name Columbia Pacific Transoort Rainier. Oregon 97048
b. Address P.O. Box 6510
c. Tel. No. (503) 556-7682 (days)

Kennewick. Washington 99336 (503) 556 7252 (nights)

c. Tel. No. (509) 586-0411 3.

Receiver

a. Name U.S. Ecology
b. Address PO Box 628 Hanford Reservation Richland. Washington 99352
c. Tel. No. (509) 377-2411 4.

Descriotion of Waste:

a.

Proper Shipping Name Highway Route Controlled Ouantity of Radioactive Material N.O.S. 7. UN2982

b. The Hazard Class Radioactive 7 c.

Identification Number UN2982

d. Total Quantity in Shipment (Ci) 5.72E+10MBg (1.54E+6 curies) e.

Basic Description Troian's Reactor Vessel and Internals. stabilized with concrete to a non-disnersable form

f. Type of Packaging Exclusive Use. Type B. as exemoted by: DOT - E - 12147
g. Name of Each Radionuclide (list all)(use back for additional space):

H-3. C-14. Mn-54. Fe-55. Co-60. Ni-59. Ni-63. Sr-90. Nb-94. Tc-99. Sb-125.Ce-144.

Eu-152. Pu-238. Pu-239. Pu-241. Pu-242. Am-241. Cm-242. Cm-243. Cm-244.1-129

h. Physical or Chemical Form Solid. Activated Metals. Metal Oxides
i. Category of Label Yellow III
j. Transport Index (Dose Rate at 1 Meter) 25 RP Form 88a RP 304 Attachment i Revision 0 Page 3 of 5 Page 16 of 22 i

Shipment Identification No.

NPF1 July 28.1999 NRC License No.

Today's Date (Mo/ Day /Yr) 5.

Additional Information for a Hichway Route Controlled Shioment The shipment is scheduled to begin during the seven-day period commencing a.

August 5.1999

b. The street address of point of origin is Troian Nuclear Plant. 71760 Columbia River Highway. Rainier. Oregon 97048 and the route to be used within that state is Columbia River Navicable Waters l

The shipment is scheduled to be transported through (or into) the following additional c.

states using the routes indicated:

Water (1) State:

Washington Entry scheduled Transport during the 7-day period commencing: August 5.1999 Rouie:

Columbia River Navigable Waters j

Land (2) State:

Washington Entry scheduled l

Transport during the 7-day period commencing:

August 7.1999 Route:

Port of Benton to U. S. Ecoloev on Hanford Reservation on non-nublic Highway

{

(3) State:

Entry scheduled I

during the 7-day period commencing:

Route:

(4) State:

Entry scheduled during the 7-day period commencing-Route:

(5) State:

Entry scheduled during the 7-day period commencing.

i Route:

d. The street address of the shipment destination is U. S. Ecology.1/4 mile East of 200 West. Hanford Reservation. Richland. Washincton The shipment is scheduled to arrive at the destination during the seven-day period e.

I commencing August 7.1999 f.

Current information concerning the shipment can be obtained from.

i Name Michael Murdock i

Address Troian Nuclear Plant 71760 Columbia River Hichway I

Rainier. Oregon 97048 Tel. No.

(503) 556-7682 Area Code (Tel. No.)

RP Form 88a RP 304 Revision 0 Page 4 of 5 Page 17 of 22

Y.."..

Shipment Identification No.

NPF1 July 28.1999 NRC License No.

Today's Date (Mo/ Day /Yr) 6.

This information is being provided by:

Organization Portland General Electric By N

\\

(Signature)

Address Troian Nuclear Plant 71760 Columbia River Highway -

Rainier. Oregon 97048

Title:

Radioactive Waste Suoervisor

7. Verification of Notification of Receint:

Person Contacted:

(1)

Agency:

Phone:

(2)

Agency:

Phone:

(3)

Agency:

Phone:

(4)

Agency:

Phone:

(5)

Agency:

Phone:

Verified By:

Title / Position:

Date:

i I

RP Form 88a RP 304 Revision 0 Page 5 of 5 Page 18 of 22

Le<

4~.

ATTACHMENT 3 1-WEEK ADVANCE NOTIFICATION INFORMATION RADIOACTIVE WASTE SHIPMENT TROJAN REACTOR VESSEL AND INTERNALS REMOVAL PROJECT SHIPMENT NUMBER:

99-080 SHIPPER & CARRIER: Portland General Electric Company (Consignor) 71760 Columbia River Hwy Rainier, OR 97048 503-556-3713 AGENTS FOR Bigge Crane and Rigging Co. (Land Haul on Trojan Site)

CARRIERS:

10700 Bigge Avenue P.O. Box 1657 San Leandro, CA 94577 510-638-8100 l

J Neil F. Lampson, Inc. (Land Haul from Port of Benton to US Ecologi P.O. Box 6510 Kennewick, WA 99336-0502 509-586-0411 Foss Maritime (Barge Transport from Trojan to Port of Benton)

A P.O. Box 83018, Portland, OR (97283-0018) 503 286-0631 CONSIGNEE:

US Ecology, Inc.

P.O. Box 638 Hanford Reservation Richland, WA 99352 509-377-2411 RADIOACTIVE MATERIAL DESCRIPTION:

49 CFR 172 description: Radioactive Material, n.o.s., 7, ID No. UN2982, RQ Waste Classification: Class C Stable Exclusive use shipment includes one Type B as Exempted DOT E-12147.

NRC Approval: Letter dated 10/29/98. as revised bv NRC letters dated 07/16/99 and 07/19/99 Package Model No:

N/A 8

Volume:

8490 ft Total Curies:

1.54E + 09 mci ROUTE Point of origin: Trojan Nuclear Plant Industrial Area (IA) in Rainier, Oregon.

Destination: US Ecology burial site on Hanford Reservation in Washington.

TPP 29-11 Page 1 of 2 Revision 0 Page 60 of 75

g.

= =.

1st Leg:

Approximately 0.25 miles over land from Trojan Industrial Area to Trojan Barge Slip on Columbia River at approximate River Mile 72.5.

2nd Leg:

Approximately 270 miles up the Columbia River from Trojan Barge Slip to Port of Benton Barge Slip in Benton County at approximate River Mile 342.8.

Includes passing through the Banneville, The Dalles, John Day, and McNary

locks, 3rd Leg:

Approximately 30 miles over land from Port of Benton Barge slip to US Ecology burial site on Hanford Reservation in Washington. The route crosses over 1 public road, Horned Rapids Rd, which Fes between Port of Benton property and the Hanford Reservation.

Planned Stop: Since the river above Pasco cannot be transited during dark hours, the tow may stop and tie-up in the Pasco area to await daylight.

DESCRIPTION OF LAND HAUL TRANSPORT VEHICLES:

A 20-axle, hydraulically-leveled platform transporter manufactured by Schuerle will be used throughout the transport to support the package and shipping cradles. The package will be restrained on the transporter by 2 shipping cradles' with straps and a nozzle restraint assembly. The loaded transporter will be approximately 105 ft long,33 ft wide,37 ft high, and weigh approximately 1E59 tons.

Prime mover for first leg of the route: Mack /Biace Crane and Ricaina Co.

Driver Name(s):

Brian Usrv for as assianed)

Prime mover for third leg of the route:

Hendrickson (2). Melro (1)/Neil F. Lamson. Inc.

Driver Name(s):

Lee Fisher. Tom Cave. Rov Fee (or as assianed)

DESCRIPTION OF MARINE VESSELS:

Barge ZB 240, U.S. Coast Guard certificated, 240 ft long, 55 ft wide,15 ft high, Official Number 1062816, registered in U.S. The loaded transporter will be supported four bolsters located over the barge longitudinal bulkheads.

Two of the following tugboats will accompany the shipment (all registered in U.S.):

P.J. Brix, Official Number:

649 705 or Noydena, Official Number:

231849 or Lewiston, Official Number:

538 759 or Clarkston, Official Namber:

514 250 SCHEDULE:

Departure from Trojan Barge Slip:

7-dav neriod beainnina 8/5/99 Arrival at Port of Benton:

7-day oeriod beainnina 8/7/99 Departure from Port of Benton:

7-day oeriod beainnina 8/7/99 Arrival at US Ecology:

7-day oeriod beainnina 8/7/99 POINT OF CONTACT FOR CURRENT INFORMATION: LS. (Pete) Peterson Ph: 503/556-7538 TPP 29-11 Page 2 of 2 Revision 0 Page 61 of 75