Text
l AVERMIE DAILY WIT POWER LEVEL DOCKET NO.
50-250 UNIT Turkey Point Unit 3 DATE March 13, 1987 COWLETED BY N.W. Grant TELEPHONE (305) 694-4432 M
Fohrmarv. 1QA7 DAY AVERAGE DAILY POWER LEVEL (n ue-met) 2/ 1/87 702 2/ 2/87 701 2/ 3/87 698 2/ 4/87 692 2/ 5/87 688 2/ 6/87 616 2/ 7/87 686 2/ 8/87 694 2/ 9/87 699 2/10/87 698 2/1(/87 678 2/12/87 659 2/13/87
-19 2/14/87
-23 2/15/87
-23 2/16/87
-24 2/17/87 394 2/18/87 695 2/19/87 696 2/20/87 696 2/21/87 682 2/22/87 627 2/23/87 683 2/24/87 698 2/25/87 701 2/26/87 693 2/27/87 695 2/28/87 698 8703180502 870316
'h PDR ADOCK 05000250 1
1 R
PDR 1
(
a.
OPERATING DATA REPORT DOCKET NO 50 - 250 DATE 3/12/87 COMPLETED BY N. W. GRANT TELEPHONE 305/694/4432 OPERATING STATUS
- 1. UNIT NAME: TURKEY POINT UNIT 3
- 2. REPORTING PERIOD: FEBRUARY 1987
- 3. LICENSED THERMAL POWER (MWT):
2200
- 4. NAMEPLATE RATING (GROSS MWE):
760
- 5. DESIGN ELECTRICAL RATING (NET MWE):
693
- 6. MAXIMUM' DEPENDABLE CAPACITY (GROSS MWE):
700
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
666
- 8. IF CHANGES OCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)________________________
- 10. REASONS FOR RESTRICTIONS, IF ANY:
MONTHLY
-YTD-CUMULATIVE
-11.-HOURS IN REPORT PERIOD:
672 1416 124785.6
-12. NUMBER OF HOURS REACTOR WAS CRITICAL _____
646.6 1280.9 87346.7
- 13. REACTOR RESERVE SHUTDOWN HOURS __________
00 0.0 344.4
- 14. HOURS GENERATOR ON-LINE _________________
574.6 1184.8 86452.3
- 15. UNIT RESERVE SHUTDOWN HOURS _____________
O O
121.8 16.. GROSS THERMAL ENERGY GENERATED (MWH) 1234335 2449470 179294877
- 17. GROSS ELECTRICAL ENERGY GERERATED (MWH) _
407005 807770 57442621
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 385810 764799 54387439
- 19. UNIT SERVICE FACTOR _____________________
85.5 83.7 69.3
- 20. UNIT AVAILABILITY FACTOR ________________
85.5 83.7 69.4
- 21. CAPACITY FACTOR (USING MDC NET) 86.2 81.1 66.9
- 22. CAPACITY FACTOR (USING DER NET) 82.8 77 9 62.9
- 23. UNIT FORCED OUTAGE RATE _________________
14.5 16.3 8.1
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS :
REFUELING 3/11/87, 81 DAYS _____________________________________________
- 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
.. - ~
~.
DDCKETNO.- 50-250 Turkey Point Unit #3 UNIT SHUTDOWNS AND POWER REDUCTIONS UNIT NAME DATE 4 arch 13. 1987 M ay
- 4. W. Grant REPORTMONTH Februarv.1987 TELIDHDNE (305) 694-4432
~y Ej Licesisee Eg Cause & Corrective
]gi i
[g
')
g'$
Aceke lo N...
lyaie E
%2
(
j Event u7 Prevent Recurrence jf e
jgg Repori =
Au 6
3 870213 F
97.4 A
3 250-87-009 HA TURBIN Governor control oil pressure orifice adjustment error' caused oil to be dumped and created a turbine / reactor trip.
Oil clean-up and relagging of of H.P. turbine was required prior i
to start up.
l I
l I
2 3
4 f Forced Reason:
Method:
Exhibit G. Inst ructions 5 Stheduled A Equipment Failure (Explain) 1-Manuel for Preparation of Data 8-Maintenance or Test 2-Manuel Scram.
Entry Sheets for Licensee C Refueling 3.Autoenalec Scram.
Event Repore ll.ER) File (NUREG.
D Regulaiory Resiriction 90her (Explain) 0161)
E Operator Trainmg & IAense I wanunatum 4-Continued 5
F Adminisisaisve 5-Load Reduction E xhibit I ; Same Source G Operainmal I itor 11'splaml l'8/77)
II.Other ll.xplain)
4
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.
50-250 UNIT Turkev Point Unit #3 DATE March 13. 1987 COMPLETED BY N.W. Grant TELEPHONE (305) 694-4432 REPORT MONTH Fahruarv. 14R7 See the " Unit Shutdown and Power Reductions" Report.
1
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-251 UNIT Turkey Point Unit 4 DATE March 13, 1987 C01FLETED BY N.W. Grant TELEPHONE (305) 694-4432 MNITH Februarv. 1987 DAY AVERAGE DAILY POWER LEVEL (M us-met) 2/ 1/87 702 1
2/ 2/87 543 2/ 3/87 698 2/ 4/87 693 2/ 5/87 692 2/ 6/87 671 2/ 7/87
-8 2/ 8/87 554 2/ 9/87 698 2/10/87 701 2/1(/87 701 2/12/07 697 2/13/87 696 2/14/87 310 2/15/87 392 2/16/87 393
(
2/17/87 437 2/18/87 679 2/19/87 683 2/20/87 686 2/21/87 381 2/22/87 267 2/23/87 679 l
2/24/87 686 l
2/25/87 693 2/26/87 691 2/27/87 689 2/28/87 689 l
l
{
OPERATING DATA REPORT DOCKET NO 50 - 251
~
DATE 3/12/87 COMPLETED BY N. W. GRANT TELEPHONE 305/694/4432 OPERATING STATUS 1.
UNIT NAME: TURKEY POINT UNIT 4 2., REPORTING PERIOD FEBRUARY 1987
- 3. LICENSED THERMAL POWER (MWT):
2200
- 4. NAMEPLATE RATING (GROSS MWE):
760 5.. DESIGN ELECTRICAL RATING (NET.MWE):
693 I
6.
MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
700
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
666
- 8. IF CHANGES OCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS:
9.
POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)________________________
- 10. REASONS FOR RESTRICTIONS, IF ANY:
MONTHLY
-YTD-CUMULATIVE
- 11. HOURS IN REPORT PERIOD:
672 1416 118517.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL _____
653.7 1312.7 81995.9
- 13. REACTOR RESERVE SHUTDOWN HOURS __________
0.0 0.0 166.6 i
l
- 14. HOURS GENERATOR ON-LINE _________________
636.4 1292.8 79180.0 i
- 15. UNIT RESERVE SHUTDOWN HOURS _____________
0 0
32.1 l
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 1276278 2713680 167477268
' 1:7. GROSS ELECTRICAL ENERGY GERERATED (MWH) _
414515 891670 53376518 1 18. NET ELECTRICAL ENERGY GENERATED (MWH) 393415 846949 50529661
- 19. UNIT SERVICE FACTOR _____________________
94.7 91.3 66.8 20.' UNIT AVAILABILITY FACTOR ________________
94.7 91.3 66.8
- 21. CAPACITY FACTOR (USING MDC NET) 87.9 89.8 65.4
- 22. CAPACITY FACTOR (USING DER NET) 84.5 86.3 61.5
- 23. UNIT FORCED OUTAGE RATE _________________
5.3 8.7 6.7
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS :
- 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: ________
,_,,.-..,..,.-.n..--,n
.,.~.. -
n.
4 DOCKETNO. 40 9R1 UNIT SHUTDOWNS AND POWER REDUCTIOiG UfGT MARGE Turkoy on4nt in it i4' n
DATE _ March l t 1QR7 NTED ay Nu crant
~
REPORT ROONTH February. 1987 TEtm000NE hno 64aad19
/
"i:
1
.} Ej
!E 3
Licensee E,
wg Camed & Correctiw Actium so j'1
]
N. i.
lhic IL E2 j$
2 s a1
' Evens a 1r Ptevens Recurrence
/
4 s'l j di g Report 8r A0 f
6 02 870207
.F 21.9 H
1 251-87-004 WG PUMPXX The 4B Intake Cooling Water Pump (ICW) was out of service for a check-l valve repair when the 4C ICW pump ~
broke a shaft cw pling. With 2 pumps out of service a unit shutdown was required.
Followlng repairs the.
unit returned to'Yull power operation 03 870214 F
0.0 A
5 HA VALVEX
. A turbine stop valve closeri csating a forced load reduction. The valve-was repaired and the unit rettTrned to full power operation.
04
'870221 F
13.5 A
1 HA VALVEX The unit was shutdown to repair a steam leak on the number 3 turbine I
control valve.
Following repairs the unit ieturned to full power ~
operation.
I y
4 f Forced Reas m'-
Meehad:
Exhibit G. Instruce6cas S StheduleJ A Lquipment Failure (Explain)
I Manual for Preparasion of Data B-Maintenance or Ts*
2-Manual Scram.
Enity Sheets for Licesince 3-Automatic Scram.
Event Report (LER) File (NUREG-C Refueling D Regulaiory Restriction 90her (Explain) 0161)
ET)perator Trainmg a l> cense I uaminatum 4-Continued 5
F Administrative 5-Load Reduction Eshibit I Same Source G Operainmal I erar fI splam)
("l77)
Il Diher (l.uplain t
s
SUMMARY
OF OPERATING EXPERIENCE L
DOCKET NO.
50-251 UNid<
Turkey Point Unit #4-e n
1 DATE March 13, 1987 e
COfAPLETED BY N.W. Grant TkLEPHONE (305) 694-4432
..s, e
REPORT MONTH February, 1987 See the " Unit Shu'tdown and Power Reductions" Report.
i.
l l
l l
l.
\\^
L h.
I
..n-..-
.----e--...
-. - - -,. ~ - - - - - -..,...,.. - -
. ~...,,
g E
AVERMiE DAILY UNIT POWER LEVEL DOCKET NO.
50-335 UNIT St. Lucie Unit 1 MTE um ms 73, iggy C(NLETED BY N.tl. Grant TELEPHONE (305) 694-4432 MNITH February. 1987 DAY AVERMiE DAILY POWER LEVEL (n m-ant) 2/ 1/87 854 2/ 2/87 853 2/ 3/87 853 2/ 4/87 850 2/ 5/87 849 2/ 6/87 811 2/ 7/87
-16 2/ 8/87
-9 2/ 9/87
-10 2/10/87
-3 2/11/87
-3 2/12/87
-3 2/13/87
-3 2/14/87
-3 2/15/87
-3 2/16/87
-3 2/17/87
-2 2/18/87
-2 2/19/87
-2 2/20/87
-2 2/21/87
-2 2/22/87
-2 2/23/87
-2 2/24/87
-2 2/25/87
-2 2/26/87
-2 2/27/87
-2 2/28/87
-2
i s-OPERATING DATA REPORT
~'
DOCKET NO 50 - 335 DATE 3/12/87 COMPLETED BY N. W. GRANT TELEPHONE 305/694/4432 OPERATING STATUS
- 1. UNIT NAME:
ST. LUCIE UNIT 1
- 2. REPORTING PERIOD FEBRUARY 1987
- 3. LICENSED THERMAL POWER (MWT): ______________ 2700
- 4. NAMEPLATE RATING (GROSS MWE):
850
- 5. DESIGN ELECTRICAL RATING (NET MWE):
830
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
872
- 7. MAXIMUM DEPENDA8LE CAPACITY (NET MWE):
839
- 8. IF CHANGES OCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)________________________
- 10. REASONS FOR RESTRICTIONS, IF ANY:
MONTHLY
-YTD-CUMULATIVE l
- 11. HOUR 3 IN REPORT PERIOD:
672 1416 89328.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL _____
144.5 888.5 65461.2
- 13. REACTOR RESERVE SHUTDOWN HOURS __________
0.0 0.0 205.3
- 14. HOURS GENERATOR ON-LINE _________________
144.5 888.5 65044.2
- 15. UNIT RESERVE SHUTDOWN HOURS _____________
0 0
39.3
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 386909 2388992 165608183
(
- 17. GROSS ELECTRICAL ENERGY GERERATED (MWH) _
128210 795800 54280945
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) ___
119338 753462 51239285 l
- 19. UNIT SERVICE FACTOR _____________________
21.5 62.8 72.8 l
- 20. UNIT AVAILABILITY FACTOR ________________
21.5 62.8 72.9
- 21. CAPACITY FACTOR (USING MDC NET) _________
21.2 63.4 71.7
- 22. CAPACITY FACTOR (USING DER NET) 21.4 64.1 70.3
- 23. UNIT FORCED OUTAGE RATE _________________
0 0
3.9 i
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS :
(
- 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
4/16/87 I
l l
f I
y.. _
,.~..__-_m.._--
,~. -.
.-.... m m
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.
50-335 UNIT St. Lucie Unit #1 DATE fiarch 13, 1987 COMPLETED BY fl.W. Grant TELEPHONE (305) 694-4432 REPORT MONTH February, 1987 i
Unit #1 was shutdown for refueling and scheduled maintenance.
In accordance with requirements of Technical Specifications 6.9.1.6, there were no challenges to PORV or safety valves during the report month.
m DOCKETNO. 50-335 UNIT SHUTDOWNS AND POWER REDUCTIONS 5t. Lucie Unit #1 UlGT NAME DATE March 13. 1987 C00Wl21ED gy N _ W Grant REPORT MONTH Fahroarv. 1987 TELEPHONE (305) 694-44V T
Ek Licensee Cause a correceive
)iE IE "s
- f Actiin so No thee h
!! 2 5
2 Event uT
$8 a's jilij Report
- M j
Prevens Rec.trence d
01 870207 s
527 5 C
1 RC FUELXX Unit # 1 was shutdown for refueling and scheduled maintenance.
3 335-87-02 IA INSTRU While Unit #1 was reducing power,to enter a scheduled refueling outage, the reactor automatically tripped on low steam generator level at approximately 3% power.
i l
i 2
3 4
I Forced Reason:
Method:
Exhibit G Instructions S Scheduled AI4: pment Failure (Explain) 1 Manual for Preparation of Data B-Maintenance or Test 2 Manual Scram.
Enity Sheets for Licensee 3-Automatic Scram.
Event ReporiILERIFile(NUREG.
C Refueling D Regulatory Resitiction 90her (Explaini 01619 E Operator Trainmg & IAcuse I saminainm 4-Continued F Administrative 5-Load Reduction 5
Exhibis 1 Same Source
(; Operatomal I s ens Il'splam) l'8177)
Il-Other 11 uplain)
AVERAGE DAILY UNIT POWER LEVEL DOCET NO.
50-389 UNIT St. Lucie Unit 2 DATE March 13, 1987 C(NLETED BY N.W. Grant TELEPHONE (305) 694-4432 m
February, 1987 DAY AVERAGE DAILY POWER LEVEL (RWe-Est) 2/ 1/87 856 2/ 2/87 810 2/ 3/87 865 2/ 4/87 865 2/ 5/87 865 2/ 6/87 864 2/ 7/87 866 2/ 8/87 866 2/ 9/87 867 2/10/87 868 2/11/87 868 2/12/87 869 2/13/87 868 2/14/87 867 2/15/87 866 2/16/87 865 l
2/17/87 864 i
2/18/87 866 l
2/19/87 867 2/20/87 868 2/21/87 867 2/22/87 867 2/23/87 868 l
2/24/87 867 2/25/87 868 2/26/87 865 2/27/87 864 2/28/87 864
OPERATING DATA REPORT
~
DOCKET NO 50 - 389 DATE 3/12/87 COMPLETED BY N. W. GRANT TELEPHONE 305/694/4432 OPERATING STATUS
- 1. UNIT NAME:
ST. LUCIE UNIT 2
- 2. REPORTING PERIOD: FEBRUARY 1987
- 3. LICENSED THERMAL POWER (MWT):
2700
- 4. NAMEPLATE RATING (GROSS MWE):
850
- 5. DESIGN ELECTRICAL RATING (NET MWE):
830
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):
882
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE):
839
- 8. IF CHANGES OCCUS IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)________________________
- 10. REASONS FOR RESTRICTIONS, IF ANY:
MONTHLY
-YTD-CUMULATIVE
- 11. HOURS IN REPORT PERIOD:
672 1416 31225.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL _____
672.0 1416.0 26791.6
- 13. REACTOR RESERVE SHUTDOWN HOURS __________
0.0 0.0 0.0
- 14. HOURS GENERATOR ON-LINE _____.___________
672.0 1416.0 26243.8
- 15. UNIT RESERVE SHUTDOWN HOURS _____________
0 0
0
- 16. GROSS THERMAL ENERSY GENERATED (MWH) 1810263 3811888 67849789
- 17. GROSS ELECTRICAL ENERGY GERERATED (MWH) 611040 1284670 22680820
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 580427 1222233-21439837
- 19. UNIT SERVICE FACTOR _____________________
100.0 100.0 84.0
- 20. UNIT AVAILABILITY FACTOR ________________
100.0 100.0 84.0
- 21. CAPACITY FACTOR (USING MDC NET) 102.9 102.9 84.4
- 22. CAPACITY FACTOR (USING DER NET) 104.1 104.0 83.9
- 23. UNIT FORCED OUTAGE RATE _________________
0 0
7.7
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS :
- 25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
s l
l l
8'
~*
DOCKETNO.
50-389 UNIT SHUIDOWNS AND F0WER REDUCTIONS UNIT MARIE. St. Lucle Unit #2 DATE March 13. 1987 cones.ETEg gy N U frant REroRTteorlm February,1987 TERMIBONE (2nen noA_aa19 s
- k s '4 Licensee E*
Cause & Cwative e
2li s
g 1
No lhee
[
E2
.3 5 n Event ay Actium to i
l
$8 al j gg g Repust a eIO O
Fee, ens Recurrence l
d i
l Unit #2 had no shutdowns or significant power reductions.
I l
+
1 1
i
)
n i
l l
I i
)
t 2
3 4
f Forced Reasim :
80eshed:
Exhibit G - Instructions 4
5 Stheduled A Equipment FailueeIEmplain) 1-teanuel lue Pseparation of Desa B-Maintenance or Test 2-tennemi Scram.
Entry Sheets for IAvnsee C Refueleg 3-Ameaniseac Scram.
Event Repet ILER) File INUREG-D Regulatory Restsiction 94)eher IEmplain) 0161)
E-Operator Tsaining & hense I uananaine 4-Continued i
5 1
F Adnunisisaisve 5-Load Reduction Eshabit 1 Same Source G Operaisemal i e ror Ihelam t l'8177)
Il-Othee II mplanil J
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.60-389 UNIT St. Lucie Unit #2 DATE March 13, 1987 COMPLETED BY N. W. Grant TELEPHONE (305) 694-4432 REPORT MONTH February, 1987 Unit #2 operated at essentially full power and had no " unit shutdowns or significant power reductions".
~ In accordance with requirements of Technical Specifications 6.9.1.6, there were no challenges to PORV or safety valves during the report month, i
1
.--.r-..-
---_.,<-,.,m,--
1-..-